MD-5060 DIGITAL MEGOHMMETER

Size: px
Start display at page:

Download "MD-5060 DIGITAL MEGOHMMETER"

Transcription

1 DIGITAL MEGOHMMETER ( M / 04A ) TECHNICAL SPECIFICATIONS OPERATING INSTRUCTIONS

2 DESCRIPTION The CIRCUTOR model MD-5060 digital electronic ohmmeter is a versatile, robust and easy-to-use equipment. It uses an efficient well experienced technology, which provides reliable, safe and accurate measurements up to 4,000,000 5kV, with 10 test voltages: 500, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500 and 5000 V. Its microprocessor-based development makes the equipment operation easier and enables the introduction of functions such as auto-range, memory, test voltage measurement, polarization and absorption Index indication, etc. Other feature that is important in this megohmmeter is negative voltages that refer to the zero potential terminal (R), for detecting moisture by means of the Evershed effect. Due to its reduced dimensions and weight, power supply autonomy and mechanical resistance, this equipment is suitable for fieldwork, and under extreme weather conditions. It is easy to carry, very simple to be operated and resistant to violent treatment, which unavoidably includes frequent bumps, extremely high or low temperatures, intense vibrations during transportation over rough roads, long exposure to direct sunlight, dust, sand and other wind-carried particles, etc. Everything without affecting its accuracy, comparable to the best laboratory instruments. CASE Moulded in high dielectric resistant plastic material. Apart from the output terminals there are no operator-accessible conducting parts. Terminals are placed on the farthest and most protected position of the box. HIGH VOLTAGE LIGHT INDICATOR A light indicator displays the occurrence of high voltage on the output terminal during the measurement and keeps lit until the discharging process has been completed. RANGE The current meter sensibility of such megohmmeters allows reliable readings of very high electric resistance. Therefore, the maximum measurement value of 4,000,000 5kV can be achieved. GUARD TERMINAL Allows the measurement of very high electric resistance values, eliminating the effect of parasite resistance whose influence is to be minimized. SHORT-CIRCUIT CURRENT The equipment provides a 1.2 ma ± 0.2 ma short-circuit current. 2

3 DIGITAL DISPLAY Alphanumeric LCD where the measurement results, the measuring unit, the analogue indication by means of a bar-graph and messages to the operator are displayed. MEGOHMMETER ACCURACY The measurement typical inaccuracy is smaller than ± 5% of the read value, between 1 MΩ and 100,000 5 kv. TEST VOLTAGE STABILITY The high voltage generator features electronic stabilization, thus keeping the test voltage constant for open circuits, with typical tolerance smaller than ± 2%, within the entire power supply voltage admissible variation range and for any weather condition within the specified limits. Due to the measurement system used, the output voltage error does not spread to the electric resistance value, since its reading is done by dividing the real voltage applied to the sample by the current value effectively circulating through it. POWER SUPPLY The MD-5060 megohmmeter is powered by built-in a rechargeable Ni-Cd battery. BUILT-IN CHRONOMETER It features time indication (in minutes and seconds) on the display left hand side. A beep is activated at every 30 and 60 seconds and every 10 minutes. ABSORPTION INDEX After 1 minute, pressing the A I key, the display shows the ABSORPTION INDEX value, calculated using the following formula A I = R 60 seconds R 30 seconds POLARIZATION INDEX After 10 minutes, pressing the P I key, the display shows the POLARIZATION INDEX value, calculated according to the following formula P I = R 10 minutes R 1 minute 3

4 AUTO POWER-OFF After 15 minutes' operation, the instrument turns itself off automatically, thanks to its unique auto-power-off system. RS 232 OUTPUT PORT Baud rate: 4800 bps 8 bits - non-parity 1 stop bit (8,n,1) Each line sent consists of the following information: Time Test Voltage Resistance value A typical line can feature the following format: 02: KV 5.89G Time is measured in minutes and seconds counted from the measurement start. Each line ends with CR LF characters If any condition occurs preventing the measurement from being done, the resistance value should be replaced by a message indicating the fault condition. A serial printer, a data collecting device, a communication software equipped PC, etc. can be connected to the megohmmeter RS232 output port. KEYPAD AT THE PANEL RIGHT HAND SIDE CASE AND CASE On/Off KEY: The first key from bottom up. When pressed, it turns the equipment on. "MEMORY" KEY. When pressed, the instrument displays the last resistance reading done with a sound signal. P I KEY. When pressed, the instrument displays the POLARIZATION INDEX value. A I. KEY. When pressed, the instrument displays the ABSORPTION INDEX value. "VOLTAGE (Vdc)" KEY. When pressed, it indicates that the instrument is at the VOLTMETER function, so it is displaying the real voltage applied to the resistor being tested. "BATTERY" KEY. It displays, when pressed, that the equipment is checking the rechargeable battery status. The case is made of high dielectric- and impact-resistant plastic material. A resistant synthetic leather carrying case provides safe and suitable transportation for the equipment and its accessories. The megohmmeter can be operated without being removed from its case. 4

5 DIMENSIONS AND WEIGHT 260 x 155 x 99 mm (cabinet outside dimensions without case). 1.8 kg (3.5 kg including accessories) SUPPLIED ACCESSORIES Each ohmmeter is supplied with: Negative voltage output cable. Return terminal cable. GUARD terminal cable with jaw connector. High voltage cable with acrylic probe. Fine synthetic leather case. Operation manual in English. Power supply for the battery charger ( 90 to 240 Vac). Computer connection cable. (RS232 port) Rechargeable Ni-Cd battery. OPERATION ENVIRONMENTAL CONDITIONS Room temperature can range from 0 C to +50 C, and moisture reaching its saturation limit, without affecting the equipment operation. 5

6 OPERATING INSTRUCTIONS 1) Check if there is no voltage across the points where the megohmmeter will be connected to, nor between them and the ground. 2) Connect the red banana jack terminal (red cable) to the megohmmeter (-V) terminal. 3) Connect the black cable to the megohmmeter (+R) terminal, with the yellow terminal to the G terminal. 4) The green terminal (GUARD) will not be always used. CIRCUTOR Application Note #32 explains the usage of Guard terminal for minimising the parasite resistance effect, whose influence one intends to minimise. If the measurement is performed between two parts, which are not grounded (for example: a transformer high and low voltage windings), the megohmmeter Guard terminal should be grounded for defining the instrument potential. Whenever a measurement is performed, the +R or the guard terminal should be grounded, but not both simultaneously. If none of these terminals are grounded, the megohmmeter can be subjected to a higher potential, hazardous to the operator; and the reading can result unstable and unreliable. If both terminals are simultaneously grounded, they will be short-circuited, and the megohmmeter will not perform the measurement. 5) Connect the free ends of the cables in use (red and black jaw connectors) to the element to be measured. 6) Choose the test voltage using the VOLTAGE SELECTOR rotary selecting switch.. 7) Check if the "MEMORY" key is free. 8) Press the "On/Off" key. This key should remain depressed and the "HIGH VOLTAGE" light indicator will be on, indicating that the megohmmeter internal generator is applying a high voltage to the element being tested. 9) For a few seconds, the self-scale smart system will search for the most convenient scale for the value being measured. Meanwhile, the display will show the message " WAIT..." Then, the display will show the measurement result using both digital (measurement value and unit) and analog displays. At 30 and 60 seconds' time, the equipment will sound a beep for reminding the operator to register the measurement at that time. If the measured value exceeds kv, the OVERRANGE message will be read. 10) During the measurement, check if the battery is charged. Press the "BATTERY" key and check the display information. If the charge is enough, it will read "BATTERY OK" or "LOW BATTERY", should it be recharged. The analogue bar-graph will give an approximate idea of the remaining charge percentage (at least 60% is required for a normal operation). 11) VOLTMETER : By pressing the VOLTAGE key, the instrument should measure the voltage effectively applied to the element being tested. 12) MESSAGES TO THE OPERATOR : The display will show the following messages to the operator: MEASURING UNIT AND RESISTANCE VALUE. TIME. Indicates the test time on the display right hand side. OVERRANGE. Whenever the measured resistance is greater than kV. 6

7 "WAIT..." The operator should wait, because the megohmmeter is automatically searching for the most convenient scale. LOW BATTERY. Battery should be recharged. VOLTAGE. Voltage value and unit effectively applied to the load. M. The instrument is at the memory function and, therefore, holding the value of the last performed measurement on the display. P I. POLARIZATION INDEX. A I ABSORPTION INDEX. SOUNDS MADE BY THE MEGOHMMETER: Change of scale BEEP. Each time the equipment changes scale automatically, a beep is heard indicating the change. Low battery BEEP, together with the corresponding intermittent warning on the display. Memory BEEP. If the memory key is activated, an intermittent BEEP will be heard. 30 seconds' elapsed time BEEP. 60 seconds' elapsed time and ABSORPTION INDEX BEEP. 10 minutes' elapsed time and POLARIZATION INDEX BEEP. Auto-power-off BEEP. The equipment has turned off automatically. ANALOGUE BAR-GRAPH. Located on the display lower part, it analogically indicates the resistance value being measured In the example above, the display should read 62.5 MΩ (if automatically set on the range up to 100 MΩ). BATTERY CHARGER. This equipment is provided with an external power supply (90 to 240Vac) and a built-in auxiliary smart circuit for charging batteries. On the panel there is a two-colour LED, indicating when the battery is being charged (red light), and when is already charged (green light). The instrument is delivered with a charged battery, but we recommend to provide an initial charge following these instructions: Connect the power supply cable plug to the connector placed on the equipment right hand side. The battery charger will operate correctly whenever the power supply is between 90 and 240 V AC. On the front panel, a red LED will remain lit until the battery is fully charged, then this LED will change to green colour. The battery normal charging time is 4 (four) hours, from discharged condition to full charge. If the battery is fully charged, it will take approximately 10 minutes to change from red to green light. 7

8 ABSORPTION INDEX A I : On this test, the megohmmeter should remain on, applying high voltage to the sample for 1 minute (60 seconds). After this time, the operator must press the A I key for reading the ABSORPTION INDEX value on the display. If he anticipates and press the key before one minute is elapsed, the display will show A I =???. The ABSORPTION INDEX is the ratio between the insulating resistance value measured at 60 seconds' time and the value measured at 30 seconds' time and it is useful for winding preventive maintenance (on transformers, motors, generators, etc.). A I = R 60 seconds R 30 seconds POLARIZATION INDEX P I : On this test, the megohmmeter should remain on, applying high voltage to the sample for 10 minutes. After this time, the operator must press the P I key, so the megohmmeter shows the P I value on the display.. If he anticipates and press the key before 10 passed minutes, the display will show P I =???. If he presses it after 10 minutes until 15 minutes, the P I will be shown. The POLARIZATION INDEX is the ratio between the insulating resistance value measured at 10 minutes' time and the value measured at 1 minute time. P I = R 10 minutes R 1 minute Approximately 5 minutes after the 10 minutes BEEP has sounded, the equipment will turn off automatically if no new function is selected (no key is pressed or reset). The POLARIZATION INDEX is useful for preventive maintenance for detecting insulation resistance degradation due to excessive dust, grease, or action of chemical or physical agents, etc. 8

9 APPLICATION NOTE # 32 USE OF GUARD TERMINAL IN MEGOHMMETERS When insulation resistance measurements are performed with megohmmeters, specially with high-sensitivity instruments measuring high resistance values, the use of the GUARD terminal avoids the harmful influence of stray resistances. In order to better explain the function of this terminal, let us start reviewing the megohmmeter basic circuit diagram of Fig. 1. Vt Ri +V I -R A Rx Guard Fig. 1 Where: V : DC high-voltage generator Ri: Generator internal resistance A : Indicator meter (microammeter) 9

10 The unknown resistance (Rx) is connected between Vt and R terminals. Its value determines the current passing through the circuit, which in turn is indicated by the microammeter. The value of Rx can be determined as follows: V Rx = - Ri I In many cases the resistance to be measured is in parallel with other stray resistances which influence on Rx should be minimum and if possible, zero. A typical example of this situation is when the insulation resistance between primary and secondary windings of a transformer mounted inside a metal housing is to be measured. Rx: Insulation resistance between primary and secondary winding. R1: Insulation resistance between primary winding and housing. R2: Insulation resistance between secondary winding and housing. If megohmmeter (terminals Vt and R) is connected to transformer terminals A and B, and considering that the resistance of the turns on each side of the transformer may be disregarded as compared with the insulation resistance between primary and secondary windings measured by megohmmeter, Rx appears to be in parallel with (R1 + R2). The situation is changed if we connect the transformer housing to GUARD terminal. 10

11 Then the resulting circuit will be: R i V I R A R A R x 1 R 2 G FIG. 3 In the circuit of Fig. 3 it may be noted that R1 is in parallel with a low-value resistance (the one from the built-in microammeter) therefore its influence is reduced during reading. Through resistance R2 circulates a current which is not passing through the meter and consequently does not affect the reading. In fact, current through R2 originates a certain error, since it creates an additional voltage drop in R1 which was not regarded during megohmmeter calibration. As regards the practical use of megohmmeter, it shall be considered that if R1 and R2 are higher than 100 MΩ, any value of Rx will be measured with an error lower than 10%. For example: Let us consider Rx = MΩ and R1 = R2 = 100 MΩ, the reading without using the GUARD terminal would be MΩ, which is quite wrong. On the other hand, if the GUARD terminal is properly used, we would have MΩ. 11

12 SAFETY CONSIDERATIONS All installation specification described at the previous chapters named INSTALLATION AND STARTUP, INSTALLATION MODES and SPECIFICATIONS. Note that with the instrument powered on, the terminals could be dangerous to touching and cover opening actions or elements removal may allow accessing dangerous parts. This instrument is factory-shipped at proper operation condition. MAINTENANCE The CVM-144 does not require any special maintenance. No adjustment, maintenance or repairing action should be done over the instrument open and powered and, should those actions are essential, high-qualified operators must perform them. Before any adjustment, replacement, maintenance or repairing operation is carried out, the instrument must be disconnected from any power supply source. When any protection failure is suspected to exist, the instrument must be immediately put our of service. The instrument s design allow a quick replacement in case of any failure. TECHNICAL SERVICE For any inquiry about the instrument performance or whether any failure happens, contact to CIRCUTOR s technical service. CIRCUTOR S.A. - After-sales service Vial Sant Jordi, s/n Viladecavalls (SPAIN) Tel fax central@circutor.es 12

MI-10kV. Technical specifications Operating instructions. Supplier:

MI-10kV. Technical specifications Operating instructions. Supplier: Technical specifications Operating instructions Supplier: Nieaf-Smitt B.V. Vrieslantlaan 6, 3526 AA Utrecht P.O. Box 7023, 3502 KA Utrecht The Netherlands T +31 30 288 1311 F +31 30 289 8816 E sales@nieaf-smitt.nl

More information

Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5

Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5 Measuring and testing equipments P 6 P.6.01 GB for substations Micro-ohmmeter MH-10 Page 3 Mega-ohmmeter MI (5, 10, 15, 20 kv) Page 4 MD (5 kv) Page 4 Indirect earth contact simulator TL-5 Page 5 Indirect

More information

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER WRM-10 TM TRANSFORMER WINDING RESISTANCE METER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 June 2009 Revision

More information

CAVA Series USER S MANUAL

CAVA Series USER S MANUAL ANALYZER OF POWER SUPPLY QUALITY CAVA Series (251 / 252 / 253) USER S MANUAL ( M98120201-20-09A ) (c) CIRCUTOR S.A. ----- Analyzer of power supply quality CAVA-251 / CAVA-252 / CAVA-253 ------- Page No.

More information

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4 Micro-ohmmeter MH-10 Page 3 MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4 Earth resistance meter TL-5 Page 5 Indirect earth contact simulator MPC (5, 20, 50 A) Page 6 Trip time tester CR

More information

DVM1190 DIGITAL MULTIMETER

DVM1190 DIGITAL MULTIMETER DIGITAL MULTIMETER 1. Introduction Thank you for buying the. This digital multimeter has a large LCD, a data-hold function and a backlight. The device uses a very practical safety mechanism that keeps

More information

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A. SUPPLY NETWORK ANALYZER CVMk SERIES & CVMk-4C SERIES INSTRUCTION MANUAL ( M 981 171 / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A. ----- Supply network analyzer CVMk and CVMk-ITF ------ Manual 1 / 2 --- Page

More information

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A. SYNCHRONISM RELAY SYNCRO-96 (Code 2 28 913-2 28 914-2 28 915) INSTRUCTION MANUAL ( M 981 196 / 99A ) (c) CIRCUTOR S.A. ----- Synchronism relay SYNCRO-96 -------- M - 981 196 --- Page nº 1 Synchronism relay

More information

AMM-1022 Digital Multimeter USER`S MANUAL

AMM-1022 Digital Multimeter USER`S MANUAL Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement

More information

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A. 3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2 (Code 7 71 071 to 7 71 083) INSTRUCTION MANUAL ( M 981 200 / 00 A ) (c) CIRCUTOR S.A. ----- MKT- MKT2 - ELECTRONIC METERS -------- M-981 200 --- Page Nº 2 3

More information

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10 CONTENTS 1. SAFETY INFORMATION.1 2. DESCRIPTION..4 3. SPECIFICATIONS.6 4. OPERATING INSTRUCTION..9 4.1 Voltage measurement...10 4.2 Current measurement 10 4.3 Resistance measurement...12 4.4 Diode test.12

More information

INSULATION TESTER SERIES

INSULATION TESTER SERIES INSULATION TESTER SERIES Field measuring instruments A Full Line-up of Insulation Testers to Suit Any Need From Basic Testing to High Performance Analysis 2 INSULATION TESTER SERIES Selection guide IR4056-20

More information

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV. MS8250A/B DIGITAL MULTIMETER OPERATION MANUAL AUTO DC AC REL hfe PCLINK % C F kmωkz nµmfav MS8250A DIGITAL MULTIMETER Auto Power Off RANGE REL HOLD FUNC NCV A ma OFF 10A A ma 10A FUSED 600V CAT IV COM

More information

GFL-1000 User Manual Ground Fault Locator

GFL-1000 User Manual Ground Fault Locator GFL-Series User Manual V1.1 GFL-1000 User Manual Ground Fault Locator Contents Contents... 1 1 Declaration of Conformity... 3 2 Introduction... 3 3 Equipment Information... 3 3.1 Safety Precautions...

More information

MIT510/2, MIT520/2 and MIT1020/2

MIT510/2, MIT520/2 and MIT1020/2 MIT510/2, MIT520/2 and MIT1020/2 Line supply or battery operated Digital/analog backlit display Measurement range to 15 TΩ (MIT510/2 and MIT520/2) and 35 TΩ (MIT1020/2) CAT IV 600 V safety rating Automatic

More information

APPA 300 Series. The Most User-Friendly High Performance Multimeter

APPA 300 Series. The Most User-Friendly High Performance Multimeter APPA 300 Series The Most User-Friendly High Performance Multimeter Throw Away the Manual... So Easy, So Simple Straight Forward... For basic application, simply to operate these keys... "LIGHT" "BAR" "DIGIT"

More information

MW3105 DIGITAL CLAMP MULTIMETER

MW3105 DIGITAL CLAMP MULTIMETER MW3105 DIGITAL CLAMP MULTIMETER 2 M MW3105 A 01 INTRODUCTION 1.1 - Unpacking and inspection Upon removing your new Digital Clamp Meter from its packing, you should have the following items: 1. Digital

More information

Testers: / Ohmmeters Insulation Measuring Instruments. n Compact and rugged for service calls and laboratory use. Scope of delivery:

Testers: / Ohmmeters Insulation Measuring Instruments. n Compact and rugged for service calls and laboratory use. Scope of delivery: Table of Contents Testers: / Ohmmeters Insulation Measuring Instruments 51 METRAOHM 413 Article: M630A Digital Low-Resistance Measuring Instrument for Measuring Protective Conductors, Equipotential Bonding

More information

MIT510, MIT520 and MIT1020

MIT510, MIT520 and MIT1020 MIT510, MIT520 and MIT1020 Line supply or battery operated Digital/analog backlit display Measurement range to 15 TΩ (MIT510 and MIT520) and 35 TΩ (MIT1020) Automatic insulation resistance tests Automatic

More information

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols

More information

Instruction Manual for Digital Grounding Resistance Meter

Instruction Manual for Digital Grounding Resistance Meter Instruction Manual for Digital Grounding Resistance Meter Instruction Manual for Digital Grounding Resistance Meter Table of Contents I. Overview...2 II. Open-case Inspection...3 III. Safety Precautions...4

More information

BM25 Automated 5-kV Insulation Tester

BM25 Automated 5-kV Insulation Tester Insulation resistance measured to >5 TΩ Automated testing Polarization Index and Step Voltage tests Dielectric discharge test for multilayer insulation RS-232 download capability Weatherproof DESCRIPTION

More information

Computer-14d - xx - 144a

Computer-14d - xx - 144a POWER FACTOR REGULATOR Computer-14d - xx - 144a INSTRUCTION MANUAL ( M 981 602 / 98B ) (c) CIRCUTOR S.A. -------- POWER FACTOR REGULATOR COMPUTER- 14d --------- Page 2 1.- POWER FACTOR REGULATORS COMPUTER-14d-144a

More information

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH AC/DC LOW CURRENT CLAMP-ON METER CM605 ENGLISH User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments

More information

OPERATOR S INSTRUCTION MANUAL

OPERATOR S INSTRUCTION MANUAL OPERATOR S INSTRUCTION MANUAL AUTO-RANGE DUAL DISPLAY CONFORMED IEC1010 DIGITAL MULTIMETER CONTENTS PAGE SAFETY INFORMATION..... DESCRIPTION.. OPERATING INSTRUCTION.. SPECIFICATIONS.... ACCESSORIES. BATTERY

More information

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2. Contents 1. General instructions. 1.1 Precautions safety measures... 1.2 Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.2 LCD Display 2.3 Keypad. 3. Function description. 3.1

More information

Multifunction AC/DC Voltage Tester

Multifunction AC/DC Voltage Tester User Manual Multifunction AC/DC Voltage Tester Model 20250-59 THE STANDARD IN PRECISION MEASUREMENT 1065DGMAN_20250-59 DS multifunctional voltage tester.indd 1 8/8/2017 1:37:47 PM Introduction The Digi-Sense

More information

5-kV and 10-kV Insulation Resistance Testers. n CAT IV 600 V safety rating. n Line supply or battery operated

5-kV and 10-kV Insulation Resistance Testers. n CAT IV 600 V safety rating. n Line supply or battery operated n CAT IV 600 V safety rating n Line supply or battery operated n Noise rejection (3mA or 4mA rms@200v and above) for use in high voltage substations or switchyards n 5mA output current provides fast charging

More information

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER with Temperature Probe Copyright 2007 Elenco Electronics, Inc. Contents 1. Safety Information 3,4 2. Safety Symbols 5 3. Front Plate

More information

M.I. Cable High Resistance Fault Locator

M.I. Cable High Resistance Fault Locator M.I. Cable High Resistance M.I. Cable High Resistance Cable Health and Safety at Work This product, when used in normal or prescribed applications within the parameters specified for mechanical and electrical

More information

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL Contents I. General...- 1 - Ⅱ. Open-package Inspection...- 2 - III. Safety Considerations... - 3 - IV.Instrument Panel & Button Function Description...- 9 -

More information

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER FALL-OF-POTENTIAL GROUND RESISTANCE TESTER Models 3620, 3640 & 4610 Call toll free (800) 537-0351 or visit www.allspec.com Measures soil resistivity (4-Point) (Model 4610) Measures ground resistance (2-

More information

Insulation resistance testing. A complete solution for every person.

Insulation resistance testing. A complete solution for every person. Insulation resistance testing. A complete solution for every person. Insulation resistance. The latest test tools from the testing experts. You asked. We responded. Now you have more insulation testing

More information

DIGIT & POINTER MULTIMETER

DIGIT & POINTER MULTIMETER CONTENTS DIGIT & POINTER MULTIMETER OPERATOR S MANUAL 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 1 1.2 DURING USE 2 1.3 SYMBOLS 3 1.4 MAINTENANCE 3 2. DESCRIPTION 4 2.1 NAMES OF COMPONENTS 4 2.2 FUNCTION

More information

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model 6012-06XR Specifications & Dimensions 2 Theory of Operation 3 System Block Diagram 4 Operator Controls & Connectors 5 Test Connections

More information

MEGATEST Owner s Manual 5000 V MEGOHMMETER. Model#: AMB-5 KVD

MEGATEST Owner s Manual 5000 V MEGOHMMETER. Model#: AMB-5 KVD MEGATEST 5000 5000 V MEGOHMMETER Model#: AMB-5 KVD Owner s Manual 1. ACCIDENT PREVENTION AND SAFETY MEASURES... 2 1.1 DURING USE... 2 1.2 AFTER USE... 3 2 OVERVIEW... 4 2.1 PURPOSE OF THE DEVICE... 5

More information

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use http://www.all-sun.com EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL V Read this owners manual thoroughly before use WARRANTY This instrument is warranted to be free from defects in material and workmanship

More information

English. Money Counter. Coin and banknote counter. DEUTsCH. Manual

English. Money Counter. Coin and banknote counter. DEUTsCH. Manual ITALIANO ESPAÑOL FRANçAIS NEDERLANDS English Money Counter DEUTsCH Coin and banknote counter Manual Money Counter for Coins and Banknotes Introduction Thank you for choosing the Money Counter series. The

More information

Preface First of all, thank you for purchasing our products, this instruction manual is the description about the function, usage, operation attention

Preface First of all, thank you for purchasing our products, this instruction manual is the description about the function, usage, operation attention AC/DC Low Frequency Current Probe CPL2000 (2000A/10kHz) Shenzhen Zhiyong Electronics Co., Ltd www.cybertek.cn Preface First of all, thank you for purchasing our products, this instruction manual is the

More information

C.A User s manual MEGOHMMETER ENGLISH

C.A User s manual MEGOHMMETER ENGLISH MEGOHMMETER C.A 6549 ENGLISH User s manual Thank you for purchasing a C.A. 6549 megohmmeter. To obtain the best service from your instrument: read this user manual carefully, comply with the precautions

More information

DC Resistance Meters 2840 Series

DC Resistance Meters 2840 Series Data Sheet DC Meters Touch screen to zoom, select, and enter values The DC resistance meters feature high accuracy and resolution measurements in the milliohm range. Both meters are ideally suited for

More information

MS2030 CAT III 600 V A V AUTO RS232

MS2030 CAT III 600 V A V AUTO RS232 MS2030 AC Digital Clamp Meter User s Manual CAT III 600 V AUTO RS232 A V CONTENTS 1.Introduction...1 2.Safety Information...1 2.1 Precautions...1 2.2 Safety Symbols...3 3. Description...4 3.1 Front Panel...4

More information

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n. MS8265 DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD ON/OFF LIGHT 1000V CAT II 600V CAT III MS8265 200K 2M 20M 20K 200M KHz 2K 20 200 2 20 200μ 200 20μ 750 2μ 1000 200n F 20n 10A 2m 200m 10 10

More information

MAGNETIC FIELD METER Operator s Manual

MAGNETIC FIELD METER Operator s Manual Edition 3.1 2009-09-03 MAGNETIC FIELD METER 2000 Operator s Manual The MFM 2000 is a professional magnetic field instrument To make the best use of the instrument we recommend that you read this manual

More information

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS CONTENTS MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 2 1.2 DURING USE 3 1.3 SYMBOLS 5 1.4 MAINTENANCE 6 2. DESCRIPTION 8 2.1 NAMES OF COMPONENTS 9

More information

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE OPERATION & SERVICE MANUAL FOR FC 100 SERIES AC POWER SOURCE FC 110 AC POWER SOURCE VERSION 1.3, April 2001. copyright reserved. DWG No. FC00001 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 1 1.1 GENERAL...

More information

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER MANUAL 600A AC Clamp Meter + NCV Model MA610 USER MANUAL 600A AC Clamp Meter + NCV Model MA610 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA610 Clamp Meter. This meter measures

More information

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY

More information

INDEX PREFACE... 1 CAUTIONS... 2 OPERATION ON SITE(9) STANDARD INSTRUMENT... 3 OPTIONAL ACCESSORIES... 4 OPERATION OF TRANSMITTER(3)...

INDEX PREFACE... 1 CAUTIONS... 2 OPERATION ON SITE(9) STANDARD INSTRUMENT... 3 OPTIONAL ACCESSORIES... 4 OPERATION OF TRANSMITTER(3)... INDEX PREFACE... 1 CAUTIONS... 2 STANDARD INSTRUMENT... 3 OPTIONAL ACCESSORIES... 4 OPERATION OF TRANSMITTER(1)... 5 (Transmitter Unit.) OPERATION OF TRANSMITTER(2)... 6 (Operation Panel, LCD Display of

More information

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS To all residents of the European Union Important environmental information about this product This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm

More information

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual Item ref: 600.104UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE User Manual Please read this manual thoroughly and ensure all contents are fully understood before using the apparatus. WARNING

More information

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer MVCT Ability to test both VT and CT Easy to use one-button automated test plans Industry leading test duration using patented simultaneous tap measurements Smallest and lightest unit on the market CT Kneepoints

More information

Insulation resistance testing. A complete solution for every application

Insulation resistance testing. A complete solution for every application Insulation resistance testing A complete solution for every application Insulation resistance The latest test tools from the testing experts You asked. We responded. Now you have more insulation testing

More information

User Manual Digital Multimeter

User Manual Digital Multimeter User Manual Digital Multimeter model no.: MSR-R500 Questions or Concerns? support@etekcity.com visit etekcity.com for more products Safe and Proper Usage Thank you for purchasing the Etekcity MSR-R500

More information

MODEL: D03128 CLAMP METER

MODEL: D03128 CLAMP METER MODEL: D03128 CLAMP METER 1 CONTENTS Page Number Details 3 Important Safety Information 3 Features 4 Product Overview 5 Switches, Buttons & Input Jacks 5 LCD 6 Specifications 6 Electrical Specifications

More information

MEGOHMMETER. User Manual

MEGOHMMETER. User Manual MEGOHMMETER 11 E N G L I S H User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable

More information

IMPULSES RADIO TRANSMISSION SYSTEM HL 630

IMPULSES RADIO TRANSMISSION SYSTEM HL 630 IMPULSES RADIO TRANSMISSION SYSTEM HL 630 OPERATING INSTRUCTIONS 1. DESCRIPTION OF THE FOUNCTIONS... Page 2 2. DESCRIPTION OF THE SYSTEM... Page 4 3. TEST AND FUNCTIONING PRINCIPLE OF THE SYSTEM... Page

More information

True RMS Digital Multimeter Model:

True RMS Digital Multimeter Model: True RMS Digital Multimeter Model: 72-7780 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,

More information

4-range High voltage insulation resistance tester KEW 3126

4-range High voltage insulation resistance tester KEW 3126 INSTRUCTION MANUAL 4-range High voltage insulation resistance tester KEW 3126 Contents 1. Safety warnings 1 2. Feature 5 3. Specification 6 4. Instrument layout 4-1 Instrument layout 9 4-2 LCD display

More information

ADAE portable X ray machine Operation manual

ADAE portable X ray machine Operation manual ADAE portable X ray machine Operation manual CONTENTS ABOUT THE SYMBOL----------------------------------------------------------3 INTRODUCTION-----------------------------------------------------------------4

More information

Fluke 125. Getting Started. Industrial ScopeMeter

Fluke 125. Getting Started. Industrial ScopeMeter Fluke 125 Industrial ScopeMeter Getting Started GB Dec 2006, Rev. 1, 09/2009 2006, 2009 Fluke Corporation, All rights reserved. Printed in The Netherlands All product names are trademarks of their respective

More information

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL AC/DC DIGITAL CLAMP METER OPERATION MANUAL HYS005661 A0 ACCESSORIES 6. ACCESSORIES 1) Test Leads: Electric Ratings 1000V 10A 1 pair (set) 2) Operating Manual 1 copy 3) 1.5V AAA Battery 3 piece - - 55 -

More information

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325 AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325 CONTENTS 1. FEATURES... 2 2. Safety precaution... 2 Symbols Description... 3 3. Specifications... 4 4. Electrical Specifications...

More information

Digital Clamp Meter Model: &

Digital Clamp Meter Model: & Digital Clamp Meter Model: 72-7224 & 72-7226 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,

More information

INSULATION TESTER SERIES. Flip the Cover. A Full Line-up of Insulation Testers to Suit Any Need. From Basic Testing to High Performance Analysis

INSULATION TESTER SERIES. Flip the Cover. A Full Line-up of Insulation Testers to Suit Any Need. From Basic Testing to High Performance Analysis INSULATION TESTER SERIES Field measuring instruments A Full Line-up of Insulation Testers to Suit Any Need Flip the Cover From Basic Testing to High Performance Analysis 2 INSULATION TESTER SERIES Selection

More information

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, this instruction manual is the description about t

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, this instruction manual is the description about t AC/DC Current Probe CPL8100A (100A/600kHz) CPL8100B (100A / 2MHz) Shenzhen Zhiyong Electronics Co., Ltd www.cybertek.cn Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing

More information

SCOPE TRM 25 TRM 25+ Transformer Winding Resistance Meter. The most advanced Transformer Winding Resistance Meter injects up to 25A DC...

SCOPE TRM 25 TRM 25+ Transformer Winding Resistance Meter. The most advanced Transformer Winding Resistance Meter injects up to 25A DC... SCOPE TRM 25 TRM 25+ Transformer Winding Resistance Meter The most advanced Transformer Winding Resistance Meter injects up to 25A DC......TRM 25 The Product TRM 25 / TRM 25+ : Advanced Transformer Winding

More information

Digital Ground Resistance Tester. Model 4610 & 4610 Kits

Digital Ground Resistance Tester. Model 4610 & 4610 Kits Digital Ground Resistance Tester Model 4610 & 4610 Kits Model 4610 shown in standard soft carrying case Catalog #2114.94 Digital Ground Resistance Tester Model 4610 performs ground resistance and soil

More information

SUPPLY NETWORK ANALYZER CVM-96 SERIES

SUPPLY NETWORK ANALYZER CVM-96 SERIES SUPPLY NETWORK ANALYZER CVM-96 SERIES (Power Demand) INSTRUCTION MANUAL ( M 981 326 / 00B - GB) (c) CIRCUTOR S.A. ----- Supply network analyzer CVM-96 ------ User's manual --- Page No. 1 CVM-96 SUPPLY

More information

M-1000D DIGITAL MULTIMETER

M-1000D DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER M-1000D Elenco Electronics, Inc. 150 Carpenter Avenue Wheeling, IL 60090 (847) 541-3800 Website: www.elenco.com e-mail: elenco@elenco.com Copyright 2008

More information

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, the product specification is about the function, u

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, the product specification is about the function, u AC/DC Current Probe CPL8100A (100A/600kHz) CPL8100B (100A / 2MHz) Shenzhen Zhiyong Electronics Co., Ltd www.cybertek.cn Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing

More information

Technical Specification Temperature-Humidity-Pressure Sensor

Technical Specification Temperature-Humidity-Pressure Sensor Technical Specification ITEM CODE RELEASE DATE AUTHOR B80951-01 24 th October 2017 T. Thiesing REVISION REVISION DATE VERSION AUTHOR B-COMMAND GmbH Gruetzmuehlenweg 46 22339 Hamburg Germany FON: +49 40

More information

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com

More information

Agilent U1251B and U1252B Handheld Digital Multimeter. Quick Start Guide

Agilent U1251B and U1252B Handheld Digital Multimeter. Quick Start Guide Agilent U1251B and U1252B Handheld Digital Multimeter Quick Start Guide The following items are included with your multimeter: Silicone test leads 4 mm probes Alligator clips Printed Quick Start Guide

More information

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01% Transportable documenting multifunction calibrator with high accuracy 0.01% CALYS 1200 is the ideal solution to simultaneously simulate and measure with a high accuracy of 0.01%: voltage, current, resistance,

More information

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS CONTENTS CONTENTS CONTENTS 1. SAFETY INFORMATION...1 1.1 Preliminary...1 1.2 Dos and don ts...2 1.3 Symbols...3 1.4 Precautions...4 2. DESCRIPTION...5 2.1 Names of parts...6 2.2 Switches, buttons and input

More information

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents I. Overview...2 II. Open-case Inspection...3 III. Safety Precautions...4 IV. Work Principle...7 V. Appearance Description...9 VI. Technical Characteristics 10 VII. Resistance Measurement Method..12 VIII.Battery

More information

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC) User Manual Compact Autoranging Clamp Meters with NIST-Traceable Calibration Models 20250-55 (400 A AC), 20250-56 (400 A AC/DC) THE STANDARD IN PRECISION MEASUREMENT 1065DGMAN_20250-55,-56 DS Clamp Meter

More information

1.General instructions Specifications Description...7

1.General instructions Specifications Description...7 USER S Manual CONTENTS 1.General instructions...1 1.1 Precautions safety measures...1 1.1.1 Preliminary...1 1.1.2 During use...2 1.1.3 Symbols...4 1.1.4 Instructions...5 1.2 Protection mechanisms...6 2.

More information

Insulation Testers and Earth Ground Testers

Insulation Testers and Earth Ground Testers Insulation Testers and Earth Ground Testers With a 5000 V MegOhmMeter for industrial-strength insulation testing and a range of compact hand-held instruments, we offer a solution for every troubleshooting

More information

BCV-1203 Barcode Verification System Users Guide Version 1.2

BCV-1203 Barcode Verification System Users Guide Version 1.2 BCV-1203 Barcode Verification System Users Guide Version 1.2 6 Clock Tower Place Suite 100 Maynard, MA 01754 USA Tel: (866) 837-1931 Tel: (978) 461-1140 FAX: (978) 461-1146 http://www.diamondt.com/ Liability

More information

User Manual Digital Multimeter. model no.: MSR-U1000

User Manual Digital Multimeter. model no.: MSR-U1000 User Manual Digital Multimeter model no.: MSR-U1000 This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes

More information

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual DUAL DISPLAY DIGITAL MULTIMETER User s Manual MS8250D 1. Safety Information Warning Use caution and follow all safety guidelines to prevent electric shock or damage to the meter. Please ready carefully

More information

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution

More information

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL Warnings and Safety symbols: Caution, refer to this manual before using the meter. Dangerous voltages. Meter is protected throughout by double insulation or

More information

IDA 4 XM V 1.X. Installation and configuration of IDA 4 XM User Manual

IDA 4 XM V 1.X. Installation and configuration of IDA 4 XM User Manual IDA 4 XM V 1.X Installation and configuration of IDA 4 XM User Manual IMPORTANT SAFETY INSTRUCTIONS - Switch the device s power off before any maintenance operation (changing the CU card, etc.) - The 24V

More information

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL GENERAL INSTRUCTIONS This instrument complies with IEC 1010-1 (61010-1@IEC: 2001), CAT. II 1000V and CAT. III 600V overvoltage standards. See Specifications.

More information

English RACON SERIES II RADIO CONTROL SERVICE MANUAL

English RACON SERIES II RADIO CONTROL SERVICE MANUAL English 22.2.2007 RACON SERIES II RADIO CONTROL SERVICE MANUAL Read the instructions supplied with the product before installation and commissioning. Keep the instructions in a safe place for future reference.

More information

Fluke 123/124 Industrial ScopeMeter

Fluke 123/124 Industrial ScopeMeter Fluke 123/124 Industrial ScopeMeter Getting started GB Sep 2002 2002 Fluke Corporation, All rights reserved. Printed in The Netherlands All product names are trademarks of their respective companies. 1

More information

3 PHASE DIGITAL POWER CLAMP METER USERS MANUAL

3 PHASE DIGITAL POWER CLAMP METER USERS MANUAL PHASE DIGITAL POWER CLAMP METER USERS MANUAL CONTENTS Safety Precautions - - - - - - - - - - - - - - - - - - - - - - - - - - - Safety Information - - - - - - - - - - - - - - - - - - - - - - - - - - - Safety

More information

ELECTRONIC CONTROL CONCEPTS 160 Partition Street Saugerties, NY or local phone

ELECTRONIC CONTROL CONCEPTS 160 Partition Street Saugerties, NY or local phone ELECTRONIC CONTROL CONCEPTS 160 Partition Street Saugerties, NY 12477 (800)VIP-XRAY (845)247-9028 Fax or 800-847-9729 local phone 845-246-9013 http://www.eccxray.com sales@eccxray.com INSTRUCTION MANUAL

More information

Table of Contents. Instruction Manual - TORBAL DRX 5 Series

Table of Contents. Instruction Manual - TORBAL DRX 5 Series Table of Contents Chapter 1.CAUTIONARY NOTES AND PRECAUTIONS... 3 Chapter 2.SPECIFICATIONS... 4 Chapter 3.Keys and display indicators... 5 Chapter 4.Parts Description... 6 Chapter 5.Unpacking the balance

More information

Model UT511 OPERATING MANUAL

Model UT511 OPERATING MANUAL Model UT511 OPERATING MANUAL TITLE PAGE Introduction Unpacking the Meter Safety Information International Electrical Symbols Battery Saver (Sleep Mode) Battery Indication The Meter Structure Display Key

More information

MS2109A AC/DC Clamp Meter. User Manual. Contents

MS2109A AC/DC Clamp Meter. User Manual. Contents MS2109A AC/DC Clamp Meter User Manual Contents 1. Safety information 1 1.1 Preparation 1 1.2 Usage 1 1.3 Signs and Labels 2 1.4 Maintenance 2 2. Description 2 2.1 Part name 3 2.2 Switch and button description

More information

DIGITAL MULTIMETER INSTRUCTION MANUAL

DIGITAL MULTIMETER INSTRUCTION MANUAL DIGITAL MULTIMETER INSTRUCTION MANUAL 1 CONTENTS CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 1 1.2 DURING USE 2 1.3 SYMBOLS 3 1.4 MAINTENANCE 4 2. DESCRIPTION 5 2.1 NAMES OF COMPONENTS 5 2.2 SWITCH,

More information

INDEX. Accessories and Components System Unit and Joystick Assembly and Charging the Battery Using with LED System...

INDEX. Accessories and Components System Unit and Joystick Assembly and Charging the Battery Using with LED System... USER GUIDE INDEX Accessories and Components... 4 System Unit and Joystick... 6 Assembly and Charging the Battery... 9 Using with LED System... 11 What is Ground Setting and How It Is Done... 14 Ground

More information

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

TRMS LEAKAGE CURRENT CLAMP-ON METER 565 TRMS LEAKAGE CURRENT CLAMP-ON METER 565 E N G L I S H User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards

More information

AMМ-3320 Multi-function LCR USER`S MANUAL

AMМ-3320 Multi-function LCR USER`S MANUAL AMМ-3320 Multi-function LCR USER`S MANUAL www.tmatlantic.com 2 Thank you for purchasing the multi-function LCR from us. Please take a few minutes to browse through this user manual before you begin to

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Digital Multimeter E 1018832 Instruction sheet 12/16 SD/UD 1 probe 1a Finger guards 2 Measurement socket 10 A for current measurement in 10-A (positive) 3 Measurement socket COM (negative)

More information

Table of Contents. Chapter 3. The 843-R Power Meter Unit.. 17

Table of Contents. Chapter 3. The 843-R Power Meter Unit.. 17 Table of Contents Chapter 1. Introduction: How to Use This Manual... 3 Chapter 2. Quick Reference... 4 2.1 Getting Started... 4 2.2 Functions with No Sensor Connected... 5 2.3 Thermal Sensors... 8 2.4

More information