Measuring is our strong point

Size: px
Start display at page:

Download "Measuring is our strong point"

Transcription

1 Measuring is our strong point Power measuring transducers E L E CT R O N manufacturing & services X

2 About us In 2008 we established ElectronXx GmbH on the This catalogue presents our range of measuring basis of more than 50 years of experience in electronics production. We produce over 250,000 components a year in the federal state of North Rhine-Westphalia (NRW). transducers. In addition to technical details, you will find all order information in a clearly organized, tabular form. Thanks our many years of experience with these constantly improved devices, we can advise you on all aspects of the diverse areas of Our specialized area of competence encompasses electronics, printed board assembly and complete device assembly. Our clientele includes leading industrial application. We look forward to your inquiries! companies as well as innovative small and medium-sized enterprises. Yours, The Management Board 2

3 Our history Beginning of construction at Heiligenhaus location Start of production of "Mechanical Measuring Devices " under AEG First use of transistors Assembly of first printed boards Conclusion of cooperation agreement AEG - Hartmann & Braun AG Hartmann & Braun AG becomes management company of Mannesmann AG Assembly of first SMD components Hartmann & Braun AG is integrated into Elsag Bailey Takeover by ABB Electronics production is outsourced to a newly formed company, ABB Electronics GmbH ABB Electronics GmbH becomes a member of the ElectronicNetwork Group and Initially operates under the company name Elektronik Zentrum West GmbH and later as EN ElectronicNetwork Heiligenhaus GmbH Spinoff of EN ElectronicNetwork Heiligenhaus GmbH from the group and launch of ElectronXx GmbH We relocate to Velbert Visit us: or 3

4 PTA 50 Analog power measuring transducer for current Preferred models for sinusoidal variables Power measuring transducer PTA 50 for current 3KDE485100L Variants for sinusoidal variables Power measuring transducer PTA 50 for current 3KDE485100V Rated current I nom = 1 A / 5 A 1 I nom = 1,2 A / 6 A 2 I nom = 2 A / 10 A 3 I nom = 2,4 A / 12 A 4 OA* No. I nom = x A / 5 * x A 9 403/404 or 404 Measuring ranges: 1 A / 5 A to 2,4 A / 12 A Accuracy class : 0,3 % Overvoltage category : III Degree of contamination : 2 Dimensions : 22,5 x 99,0 x 107,5 Degree of protection : Terminals IP20 signal 0 20 ma ma ma xx.x ma, range: 0 < xx.x < 20 ma V V xx.x V, range: 0 < xx.x < 10 V Additional order information Certificates Quality test certificate DIN (confirmation of order conformity)4) CH6 Quality test certificate DIN (with test point logging) 3,4) 499 * Order Attachment 1) For preferred models the order no. printed in bold characters up to the L is sufficient 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging PTA 50 PTA50 power measuring transducers do not require any additional power supply. The measuring transducer receives it from the measuring signal. The arithmetic mean is formed from the input variables. Sinusoidal input signals are converted into proportional root-mean-square values. The analog output can only emit dead zero signals, i.e. the output signal can only take on a value > 0 with an input signal > 0. The input signal can be max. 12 A. The double measuring ranges are always composed of a rated current x and its 5-fold value. The measuring transducers are set on a permanent basis by us and cannot be changed by the user. 4

5 PTV 50 Analog power measuring transducer for voltage Preferred models for sinusoidal variables Power measuring transducer PTV 50 for voltage 3KDE485110L Variants for sinusoidal variables Power measuring transducer PTV 50 for voltage 3KDE485110V Rated voltage U nom = 100 V / 120 V 1 U nom = 110 V / 133 V 2 U nom = 230 V / 250 V 3 U nom = 400 V 4 U nom = 500 V 5 U nom = 600 V 6 OA No.. Measuring ranges : 100 V / 120 V to 600 V max. Accuracy class : 0.3% Overvoltage category : III Degree of contamination : 2 Dimensions : 22,5 x 99,0 x 107,5 Degree of protection : Terminals IP20 U nom = x V / 1,2 * x V (2 measuring ranges only up to 250 V) 9 403/404 or 404 signal 0 20 ma ma ma 4 0 xx,x ma, range: 0 < xx,x < 20 ma V V 8 0 xx,x V, range: 0 < xx,x < 10 V Additional order information Certificates Quality test certificate DIN (confirmation of order conformity) 4) CH6 Quality test certificate DIN (with test point logging) 3)4) 499 1) For preferred models the order no. printed in bold characters up to the L is sufficient 2) Max. permissible voltage at the terminals 300/600 V, to ground 600 V 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging PTV 50 PTV50 power measuring transducers do not require any additional power supply. The measuring transducer receives it from the measuring signal. The arithmetic mean is formed from the input variables. Sinusoidal input signals are converted into proportional root-meansquare values. The analog output can only emit dead zero signals, i.e. the output signal can only take on a value > 0 with an input signal > 0. The input signal can be max. 600 V. Up to a max. input signal of 230 V, a second measuring range can be added with 1.2 times the value, but up to a max. of 250 V. The measuring transducers are set on a permanent basis by us and cannot be changed by the user. 5

6 PTM 50-AS Analog power measuring transducer for current Preferred models for sinusoidal variables Power measuring transducer PTM 50-AS for current 3KDE485120L Variants for sinusoidal variables Power measuring transducer PTM 50-AS for current 3KDE485120V Rated current I nom = 1 A / 5 A 1 I nom = 1,2 A / 6 A 2 I nom = 2 A / 10 A 3 I nom = 2,4 A / 12 A 4 OA No. I nom = x A / 5 * x A 9 401/402 or 402 Measuring ranges : 1 A / 5 A to 2,4 A / 12 A Accuracy class : 0,3 % Overvoltage category : III Degree of contamination : 2 Dimensions : 22,5 x 99,0 x 107,5 Degree of protection : Terminals IP20 signal 4 20 ma ma ma ma 4 0 xx,x ma, range: 0 < xx,x < 20 ma 6 405/ V V 8 0 xx,x V, range: 0 < xx,x < 10 V 9 407/408 Additional order information Certificates Quality test certificate DIN (confirmation of order conformity) 4) CH6 Quality test certificate DIN (with test point logging) 3)4) 499 1) For preferred models the order no. printed in bold characters up to the L is sufficient 2) Max. permissible voltage at the terminals 300/600 V, to ground 600 V 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging PTM 50-AS PTM50-AS power measuring transducers require an additional power supply. The arithmetic mean is formed from the input variables. Sinusoidal input signals are converted into proportional root-mean-square values. The analog output can also emit live zero signals, i.e. the output signal can also take on a value > 0 (e.g. 4 ma) with an input signal = 0. The max. input measuring range is 12 A. The double measuring ranges are always composed of a rated current x and its 5-fold value. The auxiliary energy is VAC ( VDC). The measuring transducers are set on a permanent basis by us and cannot be changed by the user. 6

7 PTM 50-VS Analog power measuring transducer for voltage Preferred models for sinusoidal variables Power measuring transducer PTM 50-VS for voltage 3KDE485130L OA No. Variants for sinusoidal variables Power measuring transducer PTM 50-VS for voltage 3KDE485130V Rated voltage U nom = 100 V / 120 V 1 U nom = 110 V / 133 V 2 U nom = 230 V / 250 V 3 U nom = 400 V 4 U nom = 500 V 5 U nom = 570 V 6 Measuring ranges : 100 V / 120 V to 570 V max. Accuracy class : 0,3 % Overvoltage category : III Degree of contamination : 2 Dimensions : 22,5 x 99,0 x 107,5 Degree of protection : Terminals IP20 U nom = x V / 1,2 * x V (2 measuring ranges only up to 250 V) 9 403/404 or 404 signal 4 20 ma ma ma ma 4 0 xx,x ma, range: 0 < xx,x < 20 ma 6 405/ V V 8 0 xx,x V, range: 0 < xx,x < 10 V 9 407/408 Additional order information Certificates Quality test certificate DIN (confirmation of order conformity) 4) CH6 Quality test certificate DIN (with test point logging) 3)4) 499 1) For preferred models the order no. printed in bold characters up to the L is sufficient 2) Max. permissible voltage at the terminals 300/600 V, to ground 600 V 3) Can only be ordered before production of the devic 4) This code no. is not printed on the rating plate or packaging PTM 50-VS PTM50-VS power measuring transducers require an additional power supply. The arithmetic mean is formed from the input variables. Sinusoidal input signals are converted into proportional root-mean-square values. The analog output can also emit live zero signals, i.e. the output signal can also take on a value > 0 (e.g. 4 ma) with an input signal = 0. The max. input measuring range is 570 V. The double measuring ranges are always composed of a rated voltage x and its 1.2-fold value. The auxiliary energy is VAC ( VDC). The measuring transducers are set on a permanent basis by us and cannot be changed by the user. 7

8 PTM 50-AN Digital power measuring transducer for current Preferred models for non-sinusoidal variables Power measuring transducer PTM 50-AN for current 3KDE485140L OA No. Variants for non-sinusoidal variables Power measuring transducer PTM 50-AN for current 3KDE485140V Rated current I nom = 1 A / 5 A 1 I nom = 1,2 A / 6 A 2 I nom = 2 A / 10 A 3 I nom = 2,4 A / 12 A 4 I nom = x A / 5 * x A 9 401/402 or 402 Measuring ranges : 1 A / 5 A to 2,4 A / 12 A Accuracy class : 0,3 % Overvoltage category : III Degree of contamination : 2 Dimensions : 22,5 x 99,0 x 107,5 Degree of protection : Terminals IP20 Power supply Uh = V,50/60 Hz, V DC 1 Uh = V,50/60 Hz, V DC 2 signal 4 20 ma ma ma ma ma / 4 20 ma 5 0 xx,x ma, range: 0 < xx,x < 20 ma 6 405/ V V 8 0 xx,x V, range: 0 < xx,x < 10 V 9 407/408 Additional order information Certificates Quality test certificate DIN (confirmation of order conformity) 4) CH6 Quality test certificate DIN (with test point logging) 3)4) 499 1) For preferred models the order no. printed in bold characters up to the L is sufficient 2) Max. permissible voltage at the terminals 300/600 V, to ground 600 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging PTM 50-AN PTM50-AN power measuring transducers require an additional power supply. The arithmetic mean is formed from the input variables. As a result, even non-sinusoidal input signals are converted into proportional root-meansquare values. The analog output can also emit live zero signals, i.e. the output signal can also take on a value > 0 (e.g. 4 ma) with an input signal = 0. The max. input measuring range is 12 A. The double measuring ranges are always composed of a rated current x and its 5-fold value. The measuring transducers are set on a permanent basis by us and cannot be changed by the user. 8

9 PTM 50-VN Digital power measuring transducer for voltage Preferred models for non-sinusoidal variables Power measuring transducer PTM 50-VN for voltage 3KDE485150L OA No. Variants for non-sinusoidal variables Power measuring transducer PTM 50-VN for voltage 3KDE485150V Rated voltage U nom = 100 V / 120 V 1 U nom = 110 V / 133 V 2 U nom = 230 V / 250 V 3 U nom = 400 V 4 U nom = 500 V 5 U nom = 570 V 6 Measuring ranges : 100 V / 120 V to 570 V max. Accuracy class : 0,3 % Overvoltage category : III Degree of contamination: 2 Dimensions: 22,5 x 99,0 x 107,5 Degree of protection: Terminals IP20 U nom = x V / 1,2 * x V 9 403/404 or 404 Power supply Uh = V,50/60 Hz, V DC 1 Uh = V,50/60 Hz, V DC 2 signal 4 20 ma ma ma ma ma / 4 20 ma 5 0 xx,x ma, range: 0 < xx,x < 20 ma 6 405/ V V 8 0 xx,x V, range: 0 < xx,x < 10 V 9 407/408 Additional order information Certificates Quality test certificate DIN (confirmation of order conformity) 4) CH6 Quality test certificate DIN (with test point logging) 3)4) 499 1) For preferred models the order no. printed in bold characters up to the L is sufficient 2) Max. permissible voltage at the terminals 300/600 V, to ground 600 V 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging PTM 50-VN PTM50-VN power measuring transducers require an additional power supply. The arithmetic mean is formed from the input variables. As a result, even nonsinusoidal input signals are converted into proportional root-mean-square values. The analog output can also emit live zero signals, i.e. the output signal can also take on a value > 0 (e.g. 4 ma) with an input signal = 0. The max. input measuring range is 570 V. The double measuring ranges are always composed of a rated voltage x and its 1.2-fold value. The measuring transducers are set on a permanent basis by us and cannot be changed by the user. 9

10 PTM 50-FN Digital power measuring transducer for frequency Preferred models for non-sinusoidal variables Power measuring transducer PTM 50-FN for frequency 3KDE485160L OA No. Variants for non-sinusoidal variables Power measuring transducer PTM 50-FN for frequency 3KDE485160V Rated voltage U nom = 100 V / 120 V 1 U nom = 110 V / 133 V 2 U nom = 230 V / 250 V 3 U nom = 400 V 4 U nom = 500 V 5 U nom = 570 V 6 Measuring ranges : 30 Hz to 80 Hz Accuracy class : 0,3 % Overvoltage category : III Degree of contamination: 2 Dimensions: 22,5 x 99,0 x 107,5 Degree of protection: Terminals IP20 U nom = x V / 1,2 * x V 9 403/404 or 404 Power supply Uh = V,50/60 Hz, V DC 1 Uh = V,50/60 Hz, V DC 2 signal 4 20 ma ma ma ma ma / 4 20 ma 5 0 xx,x ma, range: 0 < xx,x < 20 ma 6 405/ V V 8 0 xx,x V, range: 0 < xx,x < 10 V 9 407/408 Measuring ranges Specify starting value min. 30 Hz and max. 78 Hz in plain text Specify end value min. 32 Hz and max. 80 Hz in plain text Additional order information Certificates Quality test certificate DIN (confirmation of order conformity) 4) CH6 Quality test certificate DIN ^.2.2 (with test point logging) 3)4) 499 1) For preferred models the order no. printed in bold characters up to the L is sufficient 2) Max. permissible voltage at the terminals 300/600 V, to ground 600 V 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging PTM 50-FN PTM50-FN power measuring transducers require an additional power supply. The arithmetic mean is formed from the input variables. As a result, even non-sinusoidal input signals are converted into proportional root-meansquare values. The analog output can also emit live zero signals, i.e. the output signal can also take on a value > 0 (e.g. 4 ma) with an input signal = 0. The max. input measuring range is 570 V. The starting value of the measuring range can be min. 30 Hz and max. 78 Hz. The limits for the end value are min. 32 Hz and max. 80 Hz. The measuring transducers are set on a permanent basis by us and cannot be changed by the user. 10

11 PTK 50-1 Digital power measuring transducer for all power system variables, 1-phase Preferred models for all power system variables, root-meansquare value Power measuring transducer PTK 50-1, 1-phase 3KDE485170L OA No. Digital power measuring transducer, parameterizable for all variables in single-phase power systems or power systems with same load 2 analog outputs 1 digital outputs Accuracy class : 0,3 % Overvoltage category : III Degree of contamination: 2 Dimensions : 45,0 x 99,0 x 107,5 Degree of protection : Terminals IP20 Varians for all power system variables, root-mean-square value Power measuring transducer PTK 50-1, 1-phase 3KDE485170V 0 Rated current I nom = 1 2,5 A / 2 5 A 5 I nom = 2,4 6 A /4,8 10 A 6 Rated voltage U nom = V / V 7 U nom = V / V 8 Power supply Uh = V,50/60 Hz, V DC 1 Uh = V,50/60 Hz, V DC 2 Counication with parameterization interface RS232 1 with parameterization interface RS232 and additionally RS 485 MODBUS RTU 2 Options Delivery without customer-specific parameterization 0 Delivery with customer-specific parameterization 1 Additional order information Certificates Quality test certificate DIN (confirmation of order conformity) 4) CH6 Quality test certificate DIN (with test point logging) 3)4) 499 1) For preferred models the order no. printed in bold characters up to the L is sufficient 2) Max. permissible voltage at the terminals 300/600 V, to ground 600 V 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging PTK 50-1 These power measuring transducers require an additional power supply. The root-mean-square value is formed from the input variables. As a result, even non-sinusoidal input signals are converted into proportional root-mean-square values. The analog output is bipolar so, for example, power flow directions can also be identified via the sign. Live zero signals are possible, the output characteristic curve can also be selected as non-linear. The PTK50-1 power measuring transducer has 2 analog outputs and additionally 1 digital output (open collector). These measuring transducers are freely parameterizable. You will find further information in the separate parameterization manual. These power measuring transducers can optionally be equipped with a bus connection as well. You will find further information in the separate interface manual. An external PTD50 display can be connected to these power measuring transducers. 11

12 PTK 50-3 Digital power measuring transducer for all power system variables, 3-phase Preferred models for all power system variables, root-meansquare value Power measuring transducer PTK 50-3, 3-phase 3KDE485180L OA No. Digital power measuring transducer, parameterizable for all variables in three-phase power systems 3 analog outputs 2 digital outputs Accuracy class: 0.3% Overvoltage category: III Degree of contamination: 2 Dimensions : 67,5 x 99,0 x 107,5 Degree of protection : variants for all power system variables, root-mean-square value Power measuring transducer PTK 50-3, 3-phase 3KDE485180V 0 Rated current I nom = 1 2,5 A / 2 5 A 5 I nom = 2,4 6 A /4,8 10 A 6 Rated voltage U nom = V / V 7 U nom = V / V 8 Power supply Uh = V,50/60 Hz, V DC 1 Uh = V,50/60 Hz, V DC 2 Counication with parameterization interface RS232 1 with parameterization interface RS232 and additionally RS 485 MODBUS RTU 2 with parameterization interface RS232 and additionally CAN-BUS on request 3 Options Delivery without customer-specific parameterization 0 Delivery with customer-specific parameterization 1 Additional order information Certificates Quality test certificate DIN (confirmation of order conformity) 4) CH6 Quality test certificate DIN (with test point logging) 3)4) 499 1) For preferred models the order no. printed in bold characters up to the L is sufficient 2) Max. permissible voltage at the terminals 300/600 V, to ground 600 V 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging PTK 50-3 These power measuring transducers require an additional power supply. The root-mean-square value is formed from the input variables. As a result, even nonsinusoidal input signals are converted into proportional root-mean-square values. The analog output is bipolar so, for example, power flow directions can also be identified via the sign. Live zero signals are possible, the output characteristic curve can also be selected as nonlinear. The PTK50-3 power measuring transducer has 3 analog outputs and additionally 2 digital outputs (open collector). These measuring transducers are freely parameterizable. You will find further information in the separate parameterization manual. These power measuring transducers can optionally be equipped with a bus connection as well. You will find further information in the separate interface manual. An external PTD50 display can be connected to these power measuring transducers. 12

13 Power 50 accessories Digital measuring transducers for all power system variables PTD 50 Display for PTK 50-1 and PTK 50-3 Material No.: 3KDE485013L-0010 Dimensions: 96,0 x 96,0 x 72,0 Panel cutout : 92,0 x 92,0 (tolerance: + 0,8 ) Matching power supply: 3KDE485013L-0001 PDM Process Data Manager Material No.: V49830A Software for parameterization of PTK 50-1 and PTK 50-3 as well as for visualization of the process data Software on CD contains DRC200, PDV200, DA200-M and HDA100 Accessories: Parameterization cable for measuring transducers, model range 50 Material No.: 3KDE serial interface adapter for LKS interface Accessories The PTD50 display serves to indicate the measured values of the PTK50-1 and PTK50-3 devices. It is connected to the device via the stereo jack plug cable provided. It receives its auxiliary energy via a plug-in power supply unit (we recoend: 3KDE485013L-0001). The order and selection of the measured values to be displayed takes place during parameterization of the PTK50-1 or PTK50-3. You will find further information in the operating manual ENA3KDE485000R4283 and data sheet ENA3K- DE485000R

14 PTW 50 WEB-Server for PTK 50-3, extension of WEB-Server PTW 50 3KDE48510V Logs Modbus for PTK 50 HTTP FTP SNMP (planned) SSL (planned) Telnet DHCP Connections Ethernet RS 232 via phone plug jack I/O-connections WEB-Server PTW 50 complementing the PTK A smart meter ixmeter@work results in combination with the PTK Dimensions : 22,5 x 99,0 x 107,5 Degree of protection : Terminals IP20 PTW 50 The PTW50 Web Server is designed as an extension of the PTK50-3 and enables direct connection to a local network or to the Internet via an integrated Web Server. The Web Server makes it possible to take the meter reading with any PC offering JAVA TM capability via a Web browser. Extensive analyses are also possible. You can display the current values for voltage, current, apparent power, active power and reactive power as well as the power factors at the three current-carrying phases online at one-second intervals. The measured values are shown in the form of bar charts for the instantaneous value (including minimum and maximum value) and as line graphs. With regard to indication of the electric utility rate, the unit can optionally display the cumulative costs as well as the costs incurred based on actual consumption projected for the next minute, hour or day. You can, of course, export these values in tabular form. The Web Server can temporarily store mean values of the measured data at minute, hourly and daily intervals without connection to a PC so that retroactive analyses are also possible. 14

15 PT-SU Universal power measuring transducer for all power system variables and for network synchronization Digital measuring transducer for all power system variables and synchroscope up to 4 analog outputs and 1 digital output Accuracy class: 0,5 % Overvoltage category: III Degree of contamination: 2 Dimensions: 105,0 x 95,0 x 130,0 Degree of protection: Terminals IP20 OA No. Power measuring transducer SU V28451A- 1 3 Bauform Add-on enclosure 1 Measuring circuit Alternating current or three-phase current, balanced load 1 Three-phase current, unbalanced load (universal model) 3 Three-phase current, unbalanced load or synchroscope 4 variables Rated voltage, star connection: 30 V UN 290 V, delta: 50 V UN 500 V 1 Rated voltage, star connection: 115 V UN 490 V, delta: 200 V UN Rated current ( 0,2 A IN 1,5 A ) 1 Rated current ( 1 A IN 7,5 A ) 2 Power supply V AC/DC V AC/DC 2 24 V AC/DC 3 modules 1x ma / V; 1x binary 1 3x ma / V; 1x binary 2 4x ma / V; 1x binary 3 Interface LKS interface 0 RS 485 interface + LKS interface 1 Additional order information Factory-configured 691 Rated frequency 16 2 / 3 Hz 511 Rated frequency 400 Hz 512 Certificates Quality test certificate DIN (confirmation of order conformity) 4) Quality test certificate DIN (with test point logging) 3)4) Accessories Parameterization software Ibis E ) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging ZAV2 ZAV2 PT-SU Freely parameterizable measuring transducer for measurement of all relevant power current variables U, I, P, Q, S, cos φ, sin φ, φ, f, 4 analog outputs and 1 binary output, 4 integrated power counters Comparison of two rated voltages regarding amplitude, frequency and phase (synchroscope) Parameterization and counication via standardized interface. User-friendly parameterization software with online display of all measured variables Add-on enclosure for standard bus mounting Electrical safety according to European standard and/or IEC regulations Various characteristic curves Correct measurement even with distorted sinusoidal shape 15

16 Terminal connection diagrams The power consumption is considered to be a positive power flow direction. Currents and voltages that are not connected are not displayed. Single-phase alternating current (~)[PTA 50, PTV 50, PTM 50,...PTK50-.] Three-wire three-phase current, balanced load (3~1E) Three-wire three-phase current, unbalanced load (3~2E) Terminal connection diagrams ATTENTION The terminals of the power supply of a delta voltage are to be assigned as if it involved connection of star voltage (an artificial neutral point is formed internally in the measuring transducer). Example: You have a delta voltage of 400 V so the star voltage is 230 V. Therefore, the terminals (terminal labelling 600/300 V) of the lower voltage have to be assigned: terminals 2.2, 5.2 and 8.2 for L1, L2 and L3. 16

17 Four-wire three-phase current, balanced load (3N~1E) [PTK 50-1, PTK 50-3] Four-wire three-phase current, unbalanced load (3N~3E) [PTK 50-3] 17

18 Notices 18

19 Notices 19

20 Table of contents PTA 50 4 PTV 50 5 PTM 50-AS 6 PTM 50-VS 7 PTM 50-AN 8 PTM 50-VN 9 PTM 50-FN 10 PTK PTK PTK 50-accessories (PTD 50 und PDM) 13 PTW 50 (smart meter) 14 PT-SU 15 Accessories SU: Parameterization software Ibis E Terminal connection diagrams EL E CT R O N manufacturing & services X ElectronXx GmbH Haberstrasse 46 D Velbert Germany Telefon: Telefax: info@electronxx.de Internet: or ENA_3KDE K01R05EN

PowerIT Power Transducer Series 50

PowerIT Power Transducer Series 50 Data Sheet PowerIT Power Transducer Series 50 PTA50, PTV50, without power supply; PTM50, with power supply Power transducers with excellent cost-performance ratio Advanced technology all inputs complying

More information

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features: Application : RISH Master 3430 measures important electrical parameters in 3 phase and single phase Network & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

Data Sheet. RISH Master Record %THD

Data Sheet. RISH Master Record %THD Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

Technical Data Sheet AMIK 300 / 301

Technical Data Sheet AMIK 300 / 301 USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet AMIK 300 / 301 LISTED File No. E471457 AMIK AMIK 300 is a compact multifunction instrument with touch screen LCD utility which measures important

More information

Digital Multifunction Instrument - Rish Master 3440

Digital Multifunction Instrument - Rish Master 3440 Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters measures important electrical parameters in phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, Power, Energy

More information

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2 PART 1 PART 2 PRODUCTS 2.01 MANUFACTURERS A. Eaton products B.. C.. The listing of specific manufacturers above does not imply acceptance of their products that do not meet the specified ratings, features

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49 TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact

More information

PEM353. Universal measuring device

PEM353. Universal measuring device 353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities

More information

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I Memory 256 MB Alarm management Residual current measurement Homepage Ethernet-Modbus gateway BACnet (optional) UMG 96 RM-E Power analyser with Ethernet and RCM Communication Modbus (RTU, TCP, Gateway)

More information

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung Dimension diagrams All dimensions in mm 73 mm 10 mm 35 mm 44 mm 90 mm 90 mm 107,5 mm 50 mm 76 mm 82 mm Front view Side view Typical connection An. In R32 RS485 Dig. I/O Versorgungsspannung Auxiliary Supply

More information

AMIK 200 / 201 Technical Data Sheet

AMIK 200 / 201 Technical Data Sheet AMIK 200 / 201 Technical Data Sheet AMIK Special Features MODBUS (RS-485) Communication available only on Amik 201 On site Programmable CT/PT Ratios User selectable CT Secondary 1A/5A User selectable PT

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate True RMS AC Voltage & Current Meter with 1 Cycle Update at 50/60 Hz Features True AC or AC plus DC RMS measurement with crest factor of 3.0 at FS Fast response: reading

More information

Introduction DIN rail mounted electricity meters

Introduction DIN rail mounted electricity meters Introduction DIN rail mounted electricity meters Modular DIN Rail Products offer a wide range of functions to be integrated in electrical installations with significant benefits for the user. DIN rail

More information

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

Smart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC)

Smart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC) Smart Energy & Power Quality Solutions UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC) UMG 96RM UMG 96RM Universal measurement instrument Unrivalled in its class The UMG 96RM is a

More information

sustainable savings that can be viewed directly on the internet

sustainable savings that can be viewed directly on the internet sustainable savings that can be viewed directly on the internet MEASUREMENT, METERING & DISPLAY VIA e COMMUNICATION Measurement, metering and display, the first step towards sustainable savings Measurement,

More information

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) Tranducers for alternating current/voltage n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) and input current range (for CIP-I) n Available in single or dual output type

More information

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel

More information

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current

More information

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2 Data Sheet 066.8e Transducers for Active and Reactive Power EW 2.2 DGW 2.2 VGW 2.2 DUW 2.2 VUW 2.2 Application The E/DG/VG/DU/VU W 2.2 power transducers convert all forms of active and reactive power polarity

More information

Theta 20A / 20V. Technical Data Sheet. Special Features

Theta 20A / 20V. Technical Data Sheet. Special Features Technical Data Sheet Theta 20A / 20V Theta 20A / 20V is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal. Special Features Available in

More information

Technical Data Sheet. x1000. kwh R Y B

Technical Data Sheet. x1000. kwh R Y B Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy

More information

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus speicher MID energy meter ECSEM series Emax 2 Tariffs GridVis 7 Tariffs 8 Tariffs 14 Tariffs 0,2 kwh Class 0,5 kwh Class 1,0 kwh Class Pulse output Tarife 2 tariffs Messgenauigkeit Modbus MID M-Bus eratureingang

More information

DIRIS A40 Multifunction meters - PMD Multi-measurement meter - dimensions 3.78 x 3.78 in/96 x 96 mm

DIRIS A40 Multifunction meters - PMD Multi-measurement meter - dimensions 3.78 x 3.78 in/96 x 96 mm Single-circuit metering, measurement & analysis The solution for > Industry > Data centres > Infrastructures Function are panel mounted measurement units which ensure the user has access to all the measurements

More information

Monitoring Electric Network Via Internet

Monitoring Electric Network Via Internet Monitoring Electric Network Via Internet NETWORK ANALYSER let "it" analyse! MPR63 Real time monitoring via internet / intranet Measurement of all electrical parameters Including Harmonics Automatic recording

More information

Side view View from below Rear view

Side view View from below Rear view Dimension diagrams All dimensions in mm Side view View from below Rear view Cut out: 138 +0,8 x 138 +0,8 mm Typical connection SPS SPS 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 DSUB-9 5 4 3 2 1 8 7 6 5 4

More information

DIGITAL SYNCHRONIZING UNIT KS3.2 SERVICE MANUAL. 144 x 144 x 77 mm C E R T I F I E D

DIGITAL SYNCHRONIZING UNIT KS3.2 SERVICE MANUAL. 144 x 144 x 77 mm C E R T I F I E D DIGITAL SYNCHRONIZING UNIT KS3.2 C E R T I F I E D 144 x 144 x 77 mm SERVICE MANUAL 1 CONTENTS 1. APPLICATION... 3 2. DELIVERY SPECIFICATION... 3 3. BASIC SAFETY REQUIREMENTS AND USER S SAFETY... 4 4.

More information

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I Harmonics Temperature input Measurement accuracy 0.5 Memory 4 MByte UMG 104 Energy measurement device for DIN rails Communication Profibus (DP / V0 optional) Modbus RTU Power quality Harmonics up to 40th

More information

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485 cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement and recording of 54 power network parameters, including current and voltage harmonics up to 51st, in 1-phase 2-wire or 3-phase

More information

PLA 33. Power line analyzer. User and service manual. version 2.4

PLA 33. Power line analyzer. User and service manual. version 2.4 PLA 33 Power line analyzer User and service manual version 2.4 Content. Front control panel and terminal plate...3 7.2.2. System frequency setting...0 2. Device description...4 7.2.3. Password protection...0

More information

Applications. diris_581_d_1_gb_cat. Multimeasurement. Currents

Applications. diris_581_d_1_gb_cat. Multimeasurement. Currents Measurement units EW Applications Ethernet diris_744_a_1_cat PC Main meter panel diris_581_d_1_gb_cat COTROL VISIO software Currents per phase curve appli_384_b Monitoring and managing energy for high/low

More information

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics Power Quality Monitor Individual Harmonics measurement upto 56th Harmonics True representation of Voltage & Current waveforms. Phasor Representation of All 3 phases for system analysis Real Time Clock

More information

 Applications DIRIS A40 DIRIS A40 DIRIS A40. diris_581_e_1_gb_cat

 Applications DIRIS A40 DIRIS A40 DIRIS A40. diris_581_e_1_gb_cat Multifunction meters EW  Applications DIRIS A4 Ethernet diris_744_a cat PC Main meter panel Monitoring and managing energy for high/low voltage electrical installations  Function The and A4 are multifunction

More information

Multimeter 500CVD21 RTU500 series

Multimeter 500CVD21 RTU500 series Remote Terminal Units - Data sheet Multimeter 500CVD21 RTU500 series CT/VT interface with 4 voltage and 24 current inputs for direct monitoring of 3/4 wire 0 300 V AC (line to earth), 0...500 V AC (phase

More information

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03 Electronic AC Load Series 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A Rev. 3.03 Electronic AC Loads, Series Interface overview RS-232 USB GPIB LAN System bus Analog / Analog isolated X X Standard

More information

DIRIS A40/A41 Multifunction meters - PMD multi-measurement meter - dimensions 96 x 96 mm

DIRIS A40/A41 Multifunction meters - PMD multi-measurement meter - dimensions 96 x 96 mm Single-circuit metering, measurement & analysis The solution for > Industry > Data centres > Infrastructures DIRIS A4 Function and A4are panel mounted measurement units which ensure the user has access

More information

Applications. diris_581_e_1_gb_cat

Applications. diris_581_e_1_gb_cat Multifunction meters EW Applications Ethernet diris_744_a_1_cat PC Main meter panel Monitoring and managing energy for high/low voltage electrical installations Function The and A41 are multifunction meters

More information

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS new! cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement of power network parameters in 3- or 4-wire balanced and unbalanced systems. Color graphic display: lcd TFT 3,5, 320

More information

Energy Management Modular Power Analyzers Type WM2-96

Energy Management Modular Power Analyzers Type WM2-96 ISE, Inc. - 10100 Royalton Rd. - Cleveland, OH 44133 USA Energy Management Modular Power Analyzers Type WM2-96 - Tel: (440) 237-3200 - Fax: (440) 237-1744 - http://instserv.com Class 1 Modular power analyzer

More information

POINTAX 6000L2 Point Recorder

POINTAX 6000L2 Point Recorder GOSSEN METRAWATT CAMILLE BAUER Special Features 6 measuring channels Last printed point visible from front Electrically isolated, earth-free measuring channels Process signals ranging from 0/4... 20 ma,

More information

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks GB Technical data Issue 06/2009 PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks Fault detection Evaluation of voltage quality according to EN50160 and IEC61000-2-2 Fault recorder

More information

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS Application: The Jewell DPM Power 96x96 series measures system active Power (Import/Export), Reactive Power (Import/Export), Apparent Power & Power Factor of Three Phase and Single Phase Network. It has

More information

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters. cat iii Electrical Safety N100 - power network analyzer Measurement of power network parameters in 3 or 4-wire, balanced or unbalanced systems. two-color led display (red, green). Four quadrant energy

More information

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM Power quality Colour graphical display Ethernet connection Ethernet-Modbus gateway Graphic programming Alarm management UMG 508 Multifunction power analyser Communication Profibus (DP/V0) Modbus (RTU,

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Product Guide. Transducers

Product Guide. Transducers x y Product Guide Transducers 800.U.001.01 P/Q f for AC Current or AC Voltage: A1U / V1U 2.2 also self-powered: AU / VU 2.0 for Active or Reactive Power in single phase systems: EW / EB 2.2 in balanced

More information

Measuring centers MC7x0 series Multifunction Meter MC740

Measuring centers MC7x0 series Multifunction Meter MC740 Measuring centers MC7x0 series Multifunction Meter MC740 o Measurements of instantaneous values of more than 130 quantities (U, I, P, Q, S, PF, PA, f, φ, THD, MD, energy, energy cost by tariffs, etc.)

More information

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary Application: Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwor & replaces the multiple analog panel meters. t measures electrical parameters lie AC current,, frequency,

More information

POWER NETWORK MEASUREMENTS Analysers, Multimeters & Transducers

POWER NETWORK MEASUREMENTS Analysers, Multimeters & Transducers POWER NETWORK MEASUREMENTS Analysers, Multimeters & Transducers Measurements of electrical energy and 1 or network parameters belong to the LUMEL s main competence area. We offer in the scope of devices

More information

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices BETA Measuring /2 Product overview /3 7KT1 14, 7KT1 53 E-counters /9 7KT1 11, 7KT1 digital measuring devices /11 7KT1 0 analog measuring devices / 7KT5 8 time and pulse counters /14 7KT5 5, 7KT5 6 time

More information

MT 560/UMT TRANSDUCER & ANALYZER

MT 560/UMT TRANSDUCER & ANALYZER MT 560/UMT 560 - TRANSDUCER & ANALYZER USE The MT 560/UMT 560 multi transducer and analyzer is used for a permanent analysis of electricity supply quality in compliance with the SIST EN 50160 standard.

More information

Technical Data Sheet

Technical Data Sheet Technical Data Sheet parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters. Special Features Pulse/Limit Switch output (optional) Number of interruption Application

More information

PECA 30E. Analyseur de signaux alternatifs Signal Analyser for Electrical Networks

PECA 30E. Analyseur de signaux alternatifs Signal Analyser for Electrical Networks Analyseur de signaux alternatifs Signal Analyser for Electrical Networks Tout type de réseau : monophasé, triphasé équilibré avec ou sans neutre All types of network: single phase, 3-phase balanced, unbalanced,

More information

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Degree of protection (front): IP 40 Front dimensions: 9 DIN modules RS 422/485 Serial port by means of optional module Dual pulse

More information

PQube 3 Specifications

PQube 3 Specifications PQube 3 Specifications Reference conditions for factory tests: 19~25 C, 10%~70% RH MAINS VOLTAGE MEASURING CHANNELS Measurement Channels Power Configuration/ Range of Nominal Input Voltage 3 Line to Neutral,

More information

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A

More information

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Direct connection up to 65 A (WSx10x) Connection with current transformer (WSx30x) Industrial or meters

More information

Transducing electrical quantities Iskra MIS d.d. Measuring Transducers. Features

Transducing electrical quantities Iskra MIS d.d. Measuring Transducers. Features Measuring Transducers Transducing electrical quantities Iskra MIS d.d. Measuring Transducers Features AC, DC POWER SYSTEM MEASUREMENT MICROPROCESSOR CONTROL HOUSING FOR DIN RAIL MOUNTING IN COMPLIANCE

More information

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the

More information

Electronic timer CT-SDE

Electronic timer CT-SDE CDC 51 059 F000 1 Characteristics " 1 single time range from 0. to 0 s " versions with different supply voltage ranges are available: 4 AC/DC and 110-10 AC and 80-415 AC " Single-function timer with star-delta

More information

Smart Energy & Power Quality Solutions. Portable energy measurement devices COMPACT FLEXIBLE PRECISE

Smart Energy & Power Quality Solutions. Portable energy measurement devices COMPACT FLEXIBLE PRECISE Portable energy measurement devices COMPACT FLEXIBLE PRECISE Portable energy measurement devices COMPACT FLEXIBLE PRECISE The portable energy measurement devices from Janitza Stay flexible with the portable

More information

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR The T-W or T-V power transducer converts ac current and voltage signals into a load independent dc signal proportional to active power (watts)

More information

Digital Controller Intelligent, User-friendly Digital Controller and Programmer Controlled with ease with a support software which is input via the communication jack on the front panel. Minute adjustment

More information

Theta Hz. Technical Data Sheet. Special Features

Theta Hz. Technical Data Sheet. Special Features Technical Data Sheet Theta Hz Theta Hz the transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent

More information

DIRIS A40 DIRIS A41. Functions. Conformity to standards. Applications. Energy management DIRIS A40. Network analysis

DIRIS A40 DIRIS A41. Functions. Conformity to standards. Applications. Energy management DIRIS A40. Network analysis diris_561_b_3_x_cat 1 1. Backlit LCD display. 2. Direct access key for currents and setup wiring correction. 3. Direct access key for voltages and frequency. 4. Direct access key for active, reactive,

More information

ISOMETER IRDH575. Approvals

ISOMETER IRDH575. Approvals Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation

More information

N. TEST TEST DESCRIPTION

N. TEST TEST DESCRIPTION Multi function system for testing substation equipment such as: current, voltage and power transformers, over-current protection relays, energy meters and transducers Primary injection testing capabilities

More information

UMG 509-PRO. Multifunction power analyser with RCM

UMG 509-PRO. Multifunction power analyser with RCM UMG 509-PRO Multifunction power analyser with RCM Power quality RCM Residual current monitoring Ethernet connection Ethernet-Modbus gateway Graphic programming Alarm management Communication Profibus (DP/V0)

More information

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet 1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the

More information

Paperless Recorder PR20

Paperless Recorder PR20 Technical Information TI 075R/24/ae Paperless Recorder PR20 Economical and time saving recorder operates without the need for paper or pens and is exceedingly simple to operate Application Areas Technological

More information

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output) MODEL EM4000ACF Multifunction Transducer for alternating voltage and current Power supply voltages: Suitable for DIN-rail mounting 85 240Vac 400,440Vac 24 65Vdc 100..330Vdc V, A, W, VA, var, Hz, V, Avg.

More information

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN Energy Management Three-phase energy meter with output modules Type EM4-DIN Class 1 (active energy) Class 2 (reactive energy) Three-phase multi-function energy meter Back-lighted LCD display 3 1 / 2 DGT

More information

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM] Feature Suit for LV/ HV voltage system Compact design with all real-time measurement Consist of basic unit and optional modules 10 years back-up of integrated energy data Large LCD, high brightness High

More information

Universal measuring transducer

Universal measuring transducer Universal measuring transducer EM4000 Compact housing High accuracy Full galvanic separation MODbus (RS232/RS485) 3 Analogue + 1 Pulse output Direct voltagemeasurement up to 690V 48 hour service EXW ELEQ

More information

3-phase meter with direct connection and pulse or Modbus RS485 output

3-phase meter with direct connection and pulse or Modbus RS485 output 87045 LIMOGES Cedex Telephone: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 3-phase meter with direct connection and CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...

More information

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

ENA33LCD. Power line analyzer. User and service manual.   Obrezija 5 SI-1411 Izlake ENA33LCD Power line analyzer User and service manual version 2.9 (FW version 6.8 and newer) ETI, d.o.o. Obrezija 5 SI-1411 Izlake www.etigroup.eu/products-services 1. Front control panel and terminal plate

More information

Single phase meter with direct connection and pulse or Modbus RS485 output

Single phase meter with direct connection and pulse or Modbus RS485 output 87045 LIMOGES Cedex Telephone: +33(0)5 55 06 87 87 Fax: +33(0)5 55 06 88 88 Single phase meter with direct connection CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...

More information

DATA SHEET Selectable AC transducer TAS-311DG

DATA SHEET Selectable AC transducer TAS-311DG DATA SHEET Selectable AC transducer Measuring on AC networks Class 0.5 (IEC688) measurement Supply/measur. voltage up to 690 V Easy configuration via PC interface possible DEIF A/S Frisenborgvej 33 DK-7800

More information

Relais und Automatisierungssysteme JUST IN TIME. with the. New Generation NGG. from Schleicher NGG CATALOGUE

Relais und Automatisierungssysteme JUST IN TIME. with the. New Generation NGG. from Schleicher NGG CATALOGUE JUST IN TIME with the New Generation NGG from Schleicher NGG CATALOGUE General information on the New Generation NGG Quality control 2 Norms, regulations, approvals 2 Housing system, conductor sizes 3

More information

EMU Electronic AG. Jöchlerweg 4 CH-6340 Baar Switzerland Telefon +41 (0) Fax +41 (0)

EMU Electronic AG. Jöchlerweg 4 CH-6340 Baar Switzerland Telefon +41 (0) Fax +41 (0) EMU Electronic AG 3-phase Energy Meter with MID B and D EMU Elektronik AG Jöchlerweg 4, 6340 Baar Switzerland Tel. +41 (0)41 811 02 20 Fax +41 (0)41 811 02 21 Info@emuag.ch / www.emuag.ch Jöchlerweg 4

More information

Transienten. Datenspeicher

Transienten. Datenspeicher 25. 40. 63. Grenzwertüberwachung Oberschwingungen Power quality RCM Residual current monitoring Transienten Ethernet connection Ethernet-Modbus gateway Graphic programming Alarm management 32 MB 128 MB

More information

N. TEST TEST DESCRIPTION

N. TEST TEST DESCRIPTION Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities

More information

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5. Harmonics GridVis Analysis software Modbus interface Measurement accuracy 0.5 Universal measurement device for DIN rails Communication Protocols: Modbus RTU / Slave Interface RS485 Power quality Harmonics

More information

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions Operating Instructions SIMEAS-T s Operating Instructions Transducer without auxiliary power for alternating current for alternating voltage for alternating voltage with expanded end range 7KG6111 and 7KG6101

More information

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID Professionally approved products. Datasheet Stock Number: 144-0527 3 Phase Multi-function Power Meter 1/5A MID 96mm² Panel Mounted Power Meter. MID UK Specifications The 144-0527 is a new generation modern

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator REGULATION Automatic Synchronizer for Generator NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. NPRG870 adds

More information

Universal-Transducer Multi-E11-MU

Universal-Transducer Multi-E11-MU Universal-Transducer Multi-E11-MU Safety Informations Observe instructions! The device described in these instructions shall only be installed by a qualified electrician according to both EN 50110-1/-2

More information

UPM209 1/5A CT, 80A Multifunction three-phase meter

UPM209 1/5A CT, 80A Multifunction three-phase meter 1/5A CT, 80A Multifunction three-phase meter 4 DIN modules compact version Fully bi-directional four quadrants measurements for all energies and powers Main electrical parameters measured and displayed

More information

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet 2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection

More information

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks Threshold value monitoring Pulse outputs UMG 96L / UMG 96 Universal measurement device Measuring accuracy Energy: Class 2 Current.../1 A,.../5 A Voltage L - N: ± 1 % Networks TN-, TT-Networks 2 digital

More information

Moving Test - MT3000

Moving Test - MT3000 Moving Test - MT3000 Three-Phase Portable Test System Keep ahead with Modular Design The Modular Concept The MT3000 is based on a real modular design concept to provide the greatest possible flexibility

More information

Energy Management Modular Smart Power Transducer Type SPT-90

Energy Management Modular Smart Power Transducer Type SPT-90 Energy Management Modular Smart Power Transducer Type SPT-90 Class 0.5 (current/voltage) 16-bit µp-based modular smart power transducer Measurements of: W, Wavg, VA, VAr, PF, Wh, VAh, VArh, Amax (among

More information

new! nd40 example of application MeaSUreMent and ViSUalization of power network parameters Ethernet www/ ftp / smtp Ethernet TCP IP RS-485

new! nd40 example of application MeaSUreMent and ViSUalization of power network parameters Ethernet www/ ftp / smtp Ethernet TCP IP RS-485 new! nd40 - power network analyzer / recorder Measurement and recording of over 500 electric energy quality parameters acc. to en 50160, en 61000-4-30, en 6100-4-7 standards. Measuring class a - for 3

More information

XP2-R Power and Reverse Power Relay

XP2-R Power and Reverse Power Relay XP2-R Power and Reverse Power Relay Manual XP2-R (Revision C) Woodward Manual XP2-RE Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward

More information

M.3. Electrical measurement and control. Electrical energy meters for partial consumption

M.3. Electrical measurement and control. Electrical energy meters for partial consumption M.3 Electrical measurement and control Electrical energy meters for partial consumption M.3 Electrical energy meters for partial consumption M.3 - Electrical energy meters for partial consumption Introduction

More information