PAN-WAY T-70 AND TWIN-70 NON-METALLIC PERIMETER TRUNKING

Size: px
Start display at page:

Download "PAN-WAY T-70 AND TWIN-70 NON-METALLIC PERIMETER TRUNKING"

Transcription

1 PAN-WAY T-70 AND TWIN-70 NON-METALLIC PERIMETER TRUNKING T-70 Trunking with WORKSTATION OUTLET CENTER Offset Box Twin-70 Trunking PANDUIT NETWORK CONNECTIVITY GROUP Cable Routing Solutions. T-70 and Twin-70 multi-channel trunking provide solutions for routing low voltage, fibre optic and/ or power cabling along fixed perimeter walls. The T-70 and Twin-70 trunking systems consist of trunking base and cover, fittings and termination hardware. T-70 and Twin-70 trunking can mount NEMA standard screw-on faceplates or superior PAN-WAY Snap-On Faceplates directly to the channel. T-70 trunking can also terminate in an offset configuration using the T-70 WORKSTATION OUTLET CENTER Offset Box. T-70 Trunking: Multi-channel two-piece design for power, low voltage and fibre optic applications; Fittings maintain 25mm bend radius control for high performance copper and fibre optic cabling; Extremely tamper resistant latch design excellent for school and university applications; Fittings available to transition to Twin-70 and T-45 trunking. Twin-70 Trunking: Multi-channel three-piece design for power, low voltage and fibre optic applications; Two totally independent channels maintained throughout the system for independent access to power and low voltage, fibre optic cabling; Fittings maintain 25mm bend radius control for high performance copper and fibre optic cabling; Extremely tamper resistant latch design excellent for school and university applications; Fittings available to transition to T-70 and T-45 trunking. Sold exclusively through authorized PANDUIT distributors. 133 CYAN MAGENTA YELLOW BLACK Seite: Datum: 8/8/01

2 PAN-WAY T-70 Perimeter Trunking Base & Cover PAN-WAY Type T-70 Perimeter Trunking is an aesthetically designed, multi-channel system to route, protect and conceal data, voice, video, fibre-optic and power cabling. T-70 System Benefits: Fittings maintain the TIA/EIA required 25mm bend radius for Fibre-Optic and Category 5 cabling systems Supplied with pre-punched mounting holes Tamper resistant Compatible with: PAN-WAY Snap-On Faceplates Any U.S. Standard Screw-On Electrical/Communication Faceplate(s) 45 x 45 Electrical/Communication Faceplate(s) T70B T70C A=3323mm mm Number T-70 Trunking Base 2m lengths Number Colours 3m lengths T70BAW2 20m T70BAW3 18m T-70 trunking base in 2 or 3m lengths. Supplied with pre-punched mounting 45mm holes every 203mm. T-70 Trunking Cover T70CAW2 40m T70CAW3 36m T-70 trunking cover in 2 or 3m lengths. T-70 Trunking Divider Wall T70DW2 40m T70DW3 Grey 36m ONLY Snaps onto rails in trunking base to create separate channels. Must use with wire retainers to ensure channel separation per UL/CSA. T70DW 19mm 36mm NOTE: Order trunking base and cover separately. All parts listed in AW ( ) colour. To order other colours substitute IW (international ) and WH (). Order number of meters required, in multiples of Standard Carton Quantity. T70BC**-X T70IC T70RA T70T Type T-70 Fittings T70CC**-X T70OC T70EC T70TDT T70TDC T70TDB Number Description Colours T70BCAW-X Base Coupler Fitting T70CCAW-X Cover Coupler Fitting T70ICAW Inside Corner Fitting T70OCAW Outside Corner Fitting T70RAAW Right Angle Fitting T70ECAW End Cap Fitting Conduit breakouts: 12mm T70TAW Tee Fitting T70TDT: (Top Position) T70TDC: (Center Position) T70TDB: (Bottom Position) T-70 Trunking Divider Inserts (Power & Data Applications). Separate power and data within Tee Fitting when divider wall placed in top, center or bottom position Grey ONLY All parts listed in AW ( ) colour. To order other colours substitute IW (international ), IG (International Grey), and WH (). Order number of pieces required, in multiples of Standard Package Quantity pcs pc 10 Maintains TIA/EIA 568-A and 569-A minimum 25mm cable bend radius 134 Prime Items appear in BOLD. CYAN MAGENTA YELLOW BLACK Seite: Datum: 8/8/01

3 PAN-WAY PERIMETER TRUNKING SYSTEM Type T-70 Fittings (Continued) T70EE T70TR T70TRC T70TRI Number Description Colours T70EEAW T70TRAW Entrance End Fitting. Conduit breakouts: 12mm, 19mm, 25mm, 32mm". Entry from ceiling or wall. Transition Fitting to any LD Profile Trunking. Includes fitting for bend radius control. Maintains channel separation within T-70 trunking Base & Cover T70TRCAW Transition Fitting to any LD Profile Trunking Cover Only T70TRI Divided insert for T70 to LD2P10. Maintains channel separation within T70TR Fitting All parts listed in AW ( ) colour. To order other colours substitute IW (international ), IG (International Grey), and WH (). T-70 Trunking Accessories available on page 139 Order number of pieces required, in multiples of Standard Package Quantity. Grey ONLY Maintains TIA/EIA 568-A and 569-A minimum 25mm cable bend radius Tee Insert Configurations KEY Data Cabling Power Cabling Tee Insert Divider Wall T70TDT T70TDC T70TDB Divided Tee Inserts are used to separate power and data cabling for various tee configurations. Maintains 25mm bend radius of data cables. For Technical Assistance, refer to inside back cover for your local PANDUIT Sales Office. 135 CYAN MAGENTA YELLOW BLACK Seite: Datum: 8/8/01

4 WORKSTATION OUTLET CENTER Offset Box for T-70 Trunking T70WC T70WC2 T70WCU T70WCD Number Description Colours WORKSTATION OUTLET CENTER Offset Box For Screw-On Faceplates T70WCAW Two-piece box & bracket accept any NEMA standard faceplate. All parts listed in AW ( ) colour. To order other colours substitute IW (international ), IG (International Grey), and WH (). Order number of pieces required, in multiples of Standard Package Quantity. WORKSTATION OUTLET CENTER Offset Box For PAN-WAY Snap-On Faceplates T70WC2AW Two-piece box & bracket accept any standard electrical outlet. Accepts any PAN-WAY Snap-On Electrical/ Communication Faceplates. WORKSTATION OUTLET CENTER Offset Box For European Screw-On Faceplates T70WCUAW Two-piece box and bracket. Power box accepts twogang 86mm British Standard power devices. Communication bracket accepts PANDUIT TG80FH4 snap-on faceplate. WORKSTATION OUTLET CENTER Offset Box For European Screw-On Faceplates T70WCDAW Two-piece box and bracket. Power box accepts twogang 80mm faceplate with outlet mounting hole widths of 60.3mm. Communication bracket accepts PANDUIT TG80FH4 snap-on faceplate. WORKSTATION OUTLET CENTER Offset Box For PAN-WAY Snap-On Bezels & Faceplates T70WCF2AW Two-piece box & bracket accepts 2 gang PAN-WAY 45X45 Module Snap-On Faceplate and any PAN-WAY Classic Series Communication Snap-On Faceplate. T70WCF2 The WORKSTATION OUTLET CENTER offset box places electrical and communications devices into a common area while maximizing the cabling capacity of the trunking channel. The WORKSTATION OUTLET CENTER offset box Snap-On Faceplate version provides the lowest installed cost by reducing hardware and labour. 136 Prime Items appear in BOLD. CYAN MAGENTA YELLOW BLACK Seite: Datum: 8/8/01

5 PAN-WAY PERIMETER TRUNKING SYSTEM PAN- WAY Twin-70 Perimeter Trunking Base & Cover PAN-WAY Type Twin-70 Perimeter Trunking is an aesthetically designed system featuring two separate dedicated channels, to route, protect and conceal data, voice, video, fibre-optic and power cabling. Twin-70 System Benefits: Separate channels allow independent access to power and communication cabling throughout the entire system Fittings maintain the TIA/EIA required 25mm bend radius for Fibre-Optic and Category 5 cabling systems Tamper resistant Supplied with pre-punched mounting holes Compatible with: PAN-WAY Snap-On Faceplates Any U.S. Standard Screw-On Electrical/Communication Faceplate(s) 45 x 45 Electrical/Communication Faceplate(s) T702B A=2961mm 2 A=2961mm 2 184mm 45mm Number Twin-70 Trunking Base 2m lengths Number Colours 3m lengths T702BAW2 8m T702BAW3 9m Twin-70 trunking base in 2 or 3m lengths. Supplied with pre-punched mounting holes every 203mm. T-70 Trunking Cover T70CAW2 40m T70CAW3 36m T-70 or Twin-70 trunking tamper resistant cover in 2 or 3m lengths. NOTE: 4m of cover needed for every 2m of base. T-70 Trunking Divider Wall T70DW2 40m T70DW3 Grey 36m ONLY Snaps onto rails in trunking base to create separate channels. Must use with wire retainers to ensure channel separation per UL/CSA. T70C 36mm All parts listed in AW ( ) colour. To order other colours substitute IW (international ) and WH (). NOTE: Order trunking base and cover separately. Order number of meters required, in multiples of Standard Carton Quantity. T70DW 19mm For Technical Assistance, refer to inside back cover for your local PANDUIT Sales Office. 137 CYAN MAGENTA YELLOW BLACK Seite: Datum: 8/8/01

6 Type Twin-70 Fittings T702BC**-X T702IC T702RA T702TRL T70CC**-X T702OC T702TR T702TRI Number Description Colours T702BCAW-X Base Coupler Fitting T70CCAW-X Cover Coupler Fitting T702ICAW Inside Corner Fitting T702OCAW Outside Corner Fitting T702RAAW Right Angle Fitting T702TRAW Transition Fitting To T-70 Trunking T702TRLAW T702TRI Transition Fitting To any LD Profile Trunking Divided Insert for T702 to T70 or T702 to LD profile. Maintains channel separation within T702TR or T702TRL fitting. T702TAW Tee Fitting T702EEAW T702ECAW Entrance End Fitting Conduit breakouts: 12mm,19mm, 25mm, 32mm Entry from ceiling or wall. End Cap Fitting Conduit breakouts: 12mm pc. 5 1 pc. 5 Grey 1 pc. 5 1 pc. 5 1 pc. 5 All parts listed in AW ( ) colour. To order other colours substitute IW (international ), IG (International Grey), and WH (). Order number of pieces required, in multiples of Standard Package Quantity. Maintains TIA/EIA 568-A and 569-A minimum 25mm cable bend radius T702T T702EE T702EC Faceplate Mounting Frame for 80mm German Screw-On Faceplates T702CPAW Number Description Colour Order number of pieces required, in multiples of Standard Package. NOTE: Can only be used with Twin-70 base. Contact PANDUIT for availability. Faceplate Mounting Frame for 80mm German Screw-On Faceplates T702CPAW Two-Piece bracket. Power bracket accepts two-gang 80mm faceplate with outlet mounting holes widths of 60.3mm. Communication bracket acepts PANDUIT TG80FH4 snap-on faceplate. 138 Prime Items appear in BOLD. CYAN MAGENTA YELLOW BLACK Seite: Datum: 8/8/01

7 PAN-WAY PERIMETER TRUNKING SYSTEM Type T-70 & Twin-70 Trunking Accessories T70DB-X T70S-X T70WR-X T70SDB-X Number Description Colour Device Mounting Bracket T70DB-X Wire Retainer T70WR-X Used to mount NEMA standard single gang electrical outlets and communication devices with either screw-on or snap-on single gang faceplates. Holds wires in place. Will not interfere with cover installation. Surface Mount Box Spacer Plate T70S-X Spacer plate is used to mount a CBX4 Surface Mount Box onto the Device Bracket or Hanging Box shown above. Standard Faceplate Bracket T70SDB-X Used to mount NEMA standard single gang screw-on electrical/communication faceplates (not for use with snap-on faceplates). Order number of pieces required, in multiples of Standard Package Quantity. Grey Grey Grey ONLY 1 pc. 10 Using the spacer plate a CBX4 box can be mounted onto Twin-70 or T-70 trunking. (See PAN-NET Section) The CBX4 box features a fibre spool for managing fibre optic cable slack. T-70 Snap-On Fibre Spool Bracket NEW! T70FSB Brackets are adjustable for slack length Maintains TIA/EIA 568-A and 569-A minimum 25mm cable bend radius Number Description Colour T-70 Snap-On Fibre Spool Bracket T70FSB Fibre spool bracket that snaps onto base of T-70. Provides method to contain 1m or more of fibre slack and provides strain relief. Maintains 25mm bend radius for fibre optic Grey cabling. Bracket distance can be adjusted to fit the length of slack required. Order number of pieces required, in multiples of Standard Package. NOTE: Can be used with T-70 and Twin-70 base. Contact PANDUIT for availability Use the T70FSB with T-70 trunking to contain 1m or more of fibre slack and maintain a 25mm cable bend radius. For Technical Assistance, refer to inside back cover for your local PANDUIT Sales Office. 139 CYAN MAGENTA YELLOW BLACK Seite: Datum: 8/8/01

8 Quick Wire Fill Capacities for T-70 Perimeter Trunking This information is to be used as a guide in selecting the proper size trunking. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. A= 3323mm 2 Wirefill #1: T-70 Trunking with no devices a b A= 555mm 2 A= 1110mm 2 Wirefill #2: Power & Data using Three Sided Hanging Box and Device Bracket A= 2368mm 2 Wirefill #3: Data Only using Vertical Sloped Screw-On Communication Faceplates A= 3039mm 2 Wirefill #4: Data Only usiing Horizontal Sloped Snap-On Communication Faceplates a b A=587mm 2 A= 2013mm 2 Wirefill #5: Power & Data using the WORKSTATION OUTLET CENTER Offset Box 140 Prime Items appear in BOLD. CYAN MAGENTA YELLOW BLACK Seite: Datum: 8/8/01

9 PAN-WAY PERIMETER TRUNKING SYSTEM Quick Wire Fill Capacities for T-70 Perimeter Trunking (Continued) This information is to be used as a guide in selecting the proper size perimeter trunking. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. Trunking Channel Configurations Area (mm 2 ) CABLE DIAMETER (mm) Wirefill #1: T70 with No Devices Wirefill #2: Power & Data using the Hanging Box & Device Bracket Wirefill #3: Data Only using Screw-On Faceplates Wirefill #4: Data Only using Snap-On Bezels Wirefill #5: Power & Data using the WORKSTATION OUTLET CENTER Offset Box Trunking Channel Configurations Area (mm 2 ) CABLE DIAMETER (mm) Wirefill #1: T70 with No Devices Wirefill #2: Power & Data using the Hanging Box & Device Bracket Wirefill #3: Data Only using Screw-On Faceplates Wirefill #4: Data Only using Snap-On Bezels Wirefill #5: Power & Data using the WORKSTATION OUTLET CENTER Offset Box For Technical Assistance, refer to inside back cover for your local PANDUIT Sales Office. 141 CYAN MAGENTA YELLOW BLACK Seite: Datum: 8/8/01

10 Quick Wire Fill Capacities for Twin-70 Trunking This information is to be used as a guide in selecting the proper size trunking. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. a b A= 1323mm 2 Wirefill #1: Power & Data with No Terminations A= 923mm 2 A= 2961mm 2 Wirefill #2: One Twin-70 Channel with No Devices A= 2006mm 2 A= 2142mm 2 Wirefill #3: Data Only using Vertical Sloped Screw-On Communication Faceplates Wirefill #4: Power using Device Bracket & U.S. Standard Screw-On Faceplates A= 2671mm 2 A= 1503mm 2 Wirefill #5: Data Only using Horizontal Sloped Snap-On Communication Faceplates Wirefill #6: 20A TVSS Rectangular Outlet using Device Bracket & Snap-On Electrical/ Communication Faceplate 142 Prime Items appear in BOLD. CYAN MAGENTA YELLOW BLACK Seite: Datum: 8/8/01

11 PAN-WAY PERIMETER TRUNKING SYSTEM Quick Wire Fill Capacities for Twin-70 Perimeter Trunking (Continued) This information is to be used as a guide in selecting the proper size perimeter trunking. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. Trunking Channel Configurations Wirefill #1: Power & Data No Terminations Wirefill #2: One Twin-70 Channel with No Devices Wirefill #3: Data Only using Device Bracket & Screw-On Faceplates Wirefill #4: Power using Device Bracket & Screw-On Faceplates Wirefill #5: Data Only using Snap-On Bezels Wirefill #6: TVSS Power Device using Device Bracket & Snap-On Faceplate Area (mm 2 ) CABLE DIAMETER (mm) Trunking Channel Configurations Wirefill #1: Power & Data No Terminations Wirefill #2: One Twin-70 Channel with No Devices Wirefill #3: Data Only using Device Bracket & Screw-On Faceplates Wirefill #4: Power using Device Bracket & Screw-On Faceplates Wirefill #5: Data Only using Snap-On Bezels Wirefill #6: TVSS Power Device using Device Bracket & Snap-On Faceplate Area (mm 2 ) CABLE DIAMETER (mm) For Technical Assistance, refer to inside back cover for your local PANDUIT Sales Office. 143 CYAN MAGENTA YELLOW BLACK Seite: Datum: 8/8/01

12 NOTES 144 CYAN MAGENTA YELLOW BLACK Seite: Datum: 8/8/01

PANDUIT is a Solutions Enabler Partner for IP Communications within the Cisco Technology Developer Program.

PANDUIT is a Solutions Enabler Partner for IP Communications within the Cisco Technology Developer Program. P AN W A Y OFFICE FURNITURE RACEWAY PANDUIT is a Solutions Enabler Partner for IP Communications within the Cisco Technology Developer Program. PAN-WAY Extend the life of your office furniture investment

More information

OPTICOM Rack Mount Fiber Cassette Enclosure

OPTICOM Rack Mount Fiber Cassette Enclosure OPTICOM Rack Mount Fiber Cassette Enclosure Part Number: FCE4U Panduit Corp. 2008 INSTALLATION INSTRUCTIONS FCE4U Contents: 1 - ENCLOSURE 4 - #12-24 X 1/2" SCREWS 4 - M6X1 SCREWS 2 - #10-32 X 3/8" SCREWS

More information

The 400, 800, and 2300 Series Raceways, from

The 400, 800, and 2300 Series Raceways, from 400, 800, 2300, 2300D Series Small, Two-Piece, Nonmetallic Raceway Systems Ideal for Low Voltage and Power pplications The 400, 800, and 2300 Series Raceways, from Wiremold/Legrand, are a family of single

More information

ExpressTray. Steel Wire Basket Tray. Configuration Methods. B Connection of Straight Sections. A Quiklok Tray Connections at Record Speed

ExpressTray. Steel Wire Basket Tray. Configuration Methods. B Connection of Straight Sections. A Quiklok Tray Connections at Record Speed A Quiklok Tray Connections at Record Speed B Connection of Straight Sections In any project, installation time is key. Our patented QuikLok tray profile connects straight lengths of tray at record speed.

More information

Prestige 2Com Technical

Prestige 2Com Technical perimeter and distribution cable management Features System bend radius SOmm Exceeds Cat Se, 6 and 7 data cable requirements Attractive styling complementary to Logic Plus Aesthetic one piece fitting covers

More information

Factory Assistance: Phone: Fax: Page 1

Factory Assistance: Phone: Fax: Page 1 CABLE RUNWAY ACCESSORIES Radius Drop / Stringer Drop Provides 3 bend radius Radius drop fits 6, 12 and 18 runway made from 1-1/2 x 3/8 tubing Steel construction Includes (3) cable spools, (1) bolt, (1)

More information

OptiLine 45 Floor boxes

OptiLine 45 Floor boxes OptiLine 45 Floor outlet boxes P89490 Type Colour Dimensions A/B/C (mm) Qty per pack Ref. No. Floor outlet box including mounting frames for Altira, trim frame with four quick-fix devices and lid with

More information

150mm to 200mm. With box in comp 2 2 = 1535mm² total area 2 = 691mm² 45% space factor. C. & C. Marshall Ltd.

150mm to 200mm. With box in comp 2 2 = 1535mm² total area 2 = 691mm² 45% space factor. C. & C. Marshall Ltd. Technical information Aluminium trunking systems 295 Aluminium trunking capacity guide Trunking sizes up to 150mm Trunking sizes from 150mm to 200mm Trunking sizes over 200mm 105 1 2 105 3 Bench trunking

More information

Cable Management Solutions with DLP TM

Cable Management Solutions with DLP TM DLP trunking system P. 374-375 Selection chart for DLP trunking system P. 397 Floor boxes & Under floor boxes Technical data P. 373 DLP U-PVC adaptable trunking system Cable Management Solutions with DLP

More information

This attractive raceway conceals and

This attractive raceway conceals and Access 5000 Nonmetallic Surface Raceway System 5000 Two-Piece Multiple Channel Raceway This attractive raceway conceals and organizes electrical wiring and low-voltage cabling in a sleek, handsome molding.

More information

Norwich Technical. Trunking PERIMETER AND DISTRIBUTION. Description CABLE MANAGEMENT. Colour: White only. Material: PVCu. mkelectric.co.

Norwich Technical. Trunking PERIMETER AND DISTRIBUTION. Description CABLE MANAGEMENT. Colour: White only. Material: PVCu. mkelectric.co. CALE MANAGEMENT TECHNICAL SPECIFICATION MATERIALS PVCu materials used in the manufacture of MK products are self extinguishing non-flame propagating in accordance with S 78 Part. Extrusion material has

More information

Workstation Outlets GigaFlex PS6+ Modules Category 6

Workstation Outlets GigaFlex PS6+ Modules Category 6 C O M M E R C I A L N E T W O R K I N G C O P P E R 15.25 GigaFlex PS6+ Modules Category 6 AX101067 GigaFlex PS6+Module GigaFlex PS6+ Module The GigaFlex PS6+ Module is a punch down UTP connector based

More information

Open Up Your View With CABLE SYSTEMS

Open Up Your View With CABLE SYSTEMS Open Up Your View With CABLE SYSTEMS PRESENTED BY CROWN HERITAGE Our Cable Multiple options to accomodate any deck or stair design Marine Grade 316 stainless steel Swaging is the term used for attaching

More information

WaveTrax. Fiber Cable Management System

WaveTrax. Fiber Cable Management System Table of Contents 1. Overview... 3 2. Ordering Information... 8 Fiber Trough System... 8 Express T (Expand Trough Runs without Cutting)... 18 Mounting Brackets... 20 Vertical Fiber Management Solutions...

More information

VPN: ISBXLR. Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

VPN: ISBXLR. Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax VPN: ISBXLR Copyright 2003. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 JULY 2003 RM649-R2 RM657 RM664 RM861 RM650 RM658-R2 RM665-R2

More information

PREMISE CONNECTIVITY SYSTEMS

PREMISE CONNECTIVITY SYSTEMS PREMISE CONNECTIVITY TM Keystone Work Area Outlet Systems Category 6+ Keystone Jacks Category 5e+ Keystone Jacks Category 3 Voice Grade Keystone Jacks Keystone Jack Accessories A Multimedia Connector Modules

More information

CURVED TO PERFECTION. Range of upvc Three Compartment Trunking

CURVED TO PERFECTION. Range of upvc Three Compartment Trunking CURVED TO PERFECTION Range of upvc Three Compartment Trunking Meridian Key Features Three Compartment Trunking Design Features: Cat 6 & Cat 7 compliant. External angle, flat tee and flat angle come with

More information

Wall flashing profiles FP 60 WA 1 WA 150 WA 1 - ÜK WA 1 - Ü 150 E

Wall flashing profiles FP 60 WA 1 WA 150 WA 1 - ÜK WA 1 - Ü 150 E Wall flashing profiles FP 60 WA 1 WA 150 WA 1 - ÜK 150-275 WA 1 - Ü 150 E 1 F Ü R D I E ZU K U N FT G E DAC HT. The alwitra waterproofing system alwitra wall flashing profiles are part of the practically

More information

1 Sterling Curve Aluminium

1 Sterling Curve Aluminium 1 Sterling Curve Aluminium Sterling Curve Aluminium is a robust and stylish Cat 7a compliant perimeter dado or skirting system that is easy and cost effective to use. The adaptable system has 1 or 2 curved

More information

Installation Guide 888-4WB TRAY

Installation Guide 888-4WB TRAY Installation Guide WBT has pioneered the innovation of cabletray/basket tray in the last decade. Products such as Shaped Tray, PreForm, WBTForm and NoSplice have allowed users and installers to provide

More information

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box Concealed Service Floor Boxes 663 Series Floor Box 663-SC Multiple service floor box that delivers power, communications and data from standard conduit with no exposed service fitting Result: Open office

More information

Answer Power Beam and Boundary Screen

Answer Power Beam and Boundary Screen Answer Power Beam and Boundary Screen 5/16 MAGNETIC 3/8 If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE (888.783.3522) for immediate action by

More information

ModulLine MP 25. System overview. 1 Chain bracket. 2 Strain relief. Chain bracket flexible. Frame bridge RS-ZL. STF Steel Fix

ModulLine MP 25. System overview. 1 Chain bracket. 2 Strain relief. Chain bracket flexible. Frame bridge RS-ZL. STF Steel Fix ModulLine MP 25 System overview 1 Chain bracket 2 Strain relief Chain bracket flexible Frame bridge RS-ZL STF Steel Fix 3 2 1 140 3 Shelving system Technical data Separator TR Loading side Inside or outside

More information

PRESTIGE 3D COMPACT RANGE INTRODUCTION PERIMETER AND DISTRIBUTION FEATURES & BENEFITS CABLE MANAGEMENT

PRESTIGE 3D COMPACT RANGE INTRODUCTION PERIMETER AND DISTRIBUTION FEATURES & BENEFITS CABLE MANAGEMENT PRESTIGE 3D COMPACT RANGE INTRODUCTION completes the 3D offering with all the 3D benefits of faster installation, Cat 5e, 6 and 7 compliance and improved aesthetics, but in a smaller footprint & ideal

More information

WIREMOLD Access 5000 Series Raceway

WIREMOLD Access 5000 Series Raceway WIREMOLD Access 5000 Series Raceway Aesthetically Pleasing, Nonmetallic, Low-Profile, Multiple Channel Raceway System Access 5000 Raceway conceals and organizes electrical wiring and low-voltage cabling

More information

CABLE TRAY SYSTEM 248

CABLE TRAY SYSTEM 248 CALE TRAY SYSTEM 248 249 CALE LADDER SYSTEM 250 251 CALE LADDER SYSTEM 252 253 CALE LADDER SYSTEM Cable Ladder distance between rungs: 300 mm thickness (t) delivery length m S KL 60.203 60/2,3 200/7,8

More information

PRE-ENGINEERED HORSE STALL SYSTEMS SDFD SLIDING DOOR c/w FOLD-DOWN GRILL. & Assembly. Installation Instructions

PRE-ENGINEERED HORSE STALL SYSTEMS SDFD SLIDING DOOR c/w FOLD-DOWN GRILL. & Assembly. Installation Instructions PRE-ENGINEERED HORSE STALL SYSTEMS 4800 SDFD SLIDING DOOR c/w FOLD-DOWN GRILL & Assembly Installation Instructions 4800 SDFD Sliding Door c/w Fold-Down Grill Components - 1 3 /4" x 2" x 88" channels (2)

More information

CM340B STOP READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING SERVER CABINET FROM SKID

CM340B STOP READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING SERVER CABINET FROM SKID CM340B STOP READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING SERVER CABINET FROM SKID NET-ACCESS Server Cabinets Panduit Corp. 2010 INSTRUCTIONS CM340B CS1 (1) Base Cabinet (2) Solid Side Panels

More information

WIRE MESH CABLE TRAY

WIRE MESH CABLE TRAY 2014 WIRE MESH CABLE TRAY INSTALLATION GUIDE (CABLE BASKET) WIRE MESH CABLE TRAY (CABLE BASKET) PRODUCT INFORMATION - MAIN UNIT TECHNICAL PARAMETERS Materials Surface Finishing Thickness of coating Application

More information

COPPER / FIBER MANAGER RACK INSTALLATION INSTRUCTIONS PX Standard Release A March 2008

COPPER / FIBER MANAGER RACK INSTALLATION INSTRUCTIONS PX Standard Release A March 2008 COPPER / FIBER MANAGER RACK INSTALLATION INSTRUCTIONS PX101425 Standard Release A March 2008 A UPON RECEIPT OF YOUR Copper / Fiber Manager Rack Great care has been taken to insure that your Copper / Fiber

More information

Optical Cable Entry Facility (OCEF) Installation Instructions

Optical Cable Entry Facility (OCEF) Installation Instructions Instruction Sheet 860380690 Uniprise Solutions Optical Cable Entry Facility (OCEF) Installation Instructions General The Optical Cable Entry Facility (OCEF) cabinets store optical fiber splices between

More information

Powerlink Plus Technical

Powerlink Plus Technical CABLE MANAGEMENT mkelectric.co.uk TECHNICAL SPECIFICATION ELECTRICAL VOLTAGE RATING 63A, 250V a.c. VOLTAGE DROP L to N = 3.47 mv/a/metre run L to E = 3.47 mv/a/metre run N to E = 3.47 mv/a/metre run EARTH

More information

PRE-ENGINEERED HORSE STALL SYSTEMS 4884 HSD STANDARD SLIDING DOOR. & Assembly. Installation Instructions

PRE-ENGINEERED HORSE STALL SYSTEMS 4884 HSD STANDARD SLIDING DOOR. & Assembly. Installation Instructions PRE-ENGINEERED HORSE STALL SYSTEMS 4884 HSD STANDARD SLIDING DOOR & Assembly Installation Instructions 4884 HSD Standard Sliding Door Components Some Considerations When Choosing Your Stall System - 1

More information

Raised Floor system LIMOGES Cedex. Phone : Fax :

Raised Floor system LIMOGES Cedex. Phone : Fax : 87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 Raised Floor system CONTENTS PAGES 1.Range 1 to 3 2.Installation process 4 to 10 3.Products détails 11 to 22 4.Technical characteristics

More information

Assembly Instructions

Assembly Instructions InTandem Table System November 20 InTandem Table System - Worksurface #4 x/" 4 wood screw power beam Tools Provided T-0 Extended Torx Driver T-25 Torx Driver Additional Tools Required Soft protective

More information

SpeedPRO Raceway System

SpeedPRO Raceway System SpeedPRO Raceway System Installation and Planning Guide 860547223 Issue 2, October 2014 www.commscope.com Planning Guide 860547223 Issue 2, October 2014 2014 CommScope, Inc. All Rights Reserved. The copyright

More information

GENERAL CATALOGUE. Connectivity for workplaces

GENERAL CATALOGUE. Connectivity for workplaces GENERAL CATALOGUE Connectivity for workplaces CONTENTS GENERAL 2 General Catalogue Connectivity for workplaces WORKPLACE SOLUTIONS SIMON 500 CIMA SIMON K45 SIMON TRUNKING p. 4 p. 86 p. 150 SIMON ELECTRICAL

More information

Handleless Uni t Specification

Handleless Uni t Specification Handleless Uni t Specification QUALITY BRITISH CRAFTSMANSHIP 160 Handless Fitting Guide - Parts Index & Base Cabinet Section 1 150 325 DRAWER 870 870 870 73 73 720 720 DOOR 685 325 2 x

More information

OXYGEN INSTALLATION. Revision date

OXYGEN INSTALLATION. Revision date 12345 1 Hardware List 12345 Flat head wood screw #9 x 7/8 long with #2 Phillips drive, silver Used to attach surfaces and end panels Hex set screw ½-13 x 2 long with 1/4 hex drive, black Used on Legs Hex

More information

Risk Assessment & Safe Working Practice

Risk Assessment & Safe Working Practice RA Ref Number: 36 Revision: 3 Project/Job Number Reference Insert Job Number Approval Date: 30/03/2018 RA Description: Installing Trunking Next Review Date: 01/04/2019 Notes: Please refer to Safe Working

More information

Linear Motion and Assembly Technologies Aluminum Framing /07. Die-Cast Foundation Brackets 3-10 & 3-11

Linear Motion and Assembly Technologies Aluminum Framing /07. Die-Cast Foundation Brackets 3-10 & 3-11 -0 Linear Motion and ssembly Technologies luminum Framing 91 500 1 /07 Section : Profile onnectors Overview One of the greatest strengths of the osch Rexroth structural aluminum framing system is the wide

More information

ELPMB27. Short Throw Projector Wall Mount Installation Manual xxx(fr) xxx(de) xxx(it) xxx(es) xxx(pt) xxx(zhs)

ELPMB27. Short Throw Projector Wall Mount Installation Manual xxx(fr) xxx(de) xxx(it) xxx(es) xxx(pt) xxx(zhs) ELPMB27 Short Throw Projector Wall Mount Installation Manual xxx(fr) xxx(de) xxx(it) xxx(es) xxx(pt) xxx(zhs) Safety Instructions Before using the wall mount, make sure you read all of the safety instructions

More information

A - Railing Frame Material Specifications

A - Railing Frame Material Specifications A - Railing Frame Material Specifications NOTE: We strongly recommend stainless steel for exterior applications. R-1 8/1/02 B Stainless Steel Spacers (For Horizontal Railing Double Post End Post using

More information

General Installation Instructions

General Installation Instructions General Installation Instructions WARNING To reduce the risk of death, injury or property damage from fire, electric shock, cuts, abrasions, falling parts and other hazards: Service of the equipment must

More information

POWER, VOICE AND DATA ACCESSORIES FOR TRUNKING

POWER, VOICE AND DATA ACCESSORIES FOR TRUNKING POWER, VOICE AND DATA ACCESSORIES FOR TRUNKING A range of flush and surface accessories that are compatible with Marshall-Tufflex trunking systems. 228 MT32 pre-wired modular accessories Power, voice and

More information

Pinnacle Technical. Bench and Shelf Trunking. cable management perimeter and distribution. Features.

Pinnacle Technical. Bench and Shelf Trunking. cable management perimeter and distribution.   Features. 604 Pinnacle Technical cable management perimeter and distribution www.mkelectric.co.uk Bench and Shelf Trunking Features l Available in a single or double configuration l May be fitted either direct to

More information

N ETWOR KS FHX 8-PORT FIBER ENCLOSURE USER MANUAL

N ETWOR KS FHX 8-PORT FIBER ENCLOSURE USER MANUAL N ETWOR KS FHX 8-PORT FIBER ENCLOSURE USER MANUAL Contents Safety Information... I Chapter 1 Installation Instructions... 1 1.1 Package Contents... 1 1.2 Carton Contents... 2 1.3 Labeling... 2 1.4 Installing

More information

METALWORKS Concealed. Installation Instructions

METALWORKS Concealed. Installation Instructions METALWORKS Concealed Installation Instructions 1. GENERAL 1.1 Product Description MetalWorks Concealed ceilings consist of perforated and unperforated panels that are downward accessible, and are designed

More information

Fortress Railing Overview ACTUAL FREIGHT CHARGES APPLY TO ALL FORTRESS RAIL ORDERS

Fortress Railing Overview ACTUAL FREIGHT CHARGES APPLY TO ALL FORTRESS RAIL ORDERS Fortress Railing Overview 4 3 1 Fe 26 Iron Railing Systems Fortress Use the steps below for the following pages to complete your rail Vertical Cable and Glass Options Available Fortress Iron Railing System

More information

Fortress Vertical Cable Overview ACTUAL FREIGHT CHARGES APPLY TO ALL FORTRESS RAIL ORDERS

Fortress Vertical Cable Overview ACTUAL FREIGHT CHARGES APPLY TO ALL FORTRESS RAIL ORDERS Fortress Vertical Cable Overview 2 5 4 1 Use the steps below for the following pages to complete your rail system 6 Rails Include 1 Cable Support 8 Rails Include 2 Cable Supports 3 160 Fortress Vertical

More information

Distributed Design D SERIES D10 TWO-WAY 10-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

Distributed Design D SERIES D10 TWO-WAY 10-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS APPLICATIONS Convention centers, exhibit halls Corporate training rooms, ballrooms Athletic venues, sports facilities, health clubs Houses of worship Malls, airports FEATURES High intelligibility with

More information

Distributed Design D SERIES D8 TWO-WAY 8-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

Distributed Design D SERIES D8 TWO-WAY 8-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS APPLICATIONS Convention centers, exhibit halls Corporate training rooms, ballrooms Athletic venues, sports facilities, health clubs Houses of worship Malls, airports FEATURES High intelligibility with

More information

Outdoor Enclosure. VIVOTEK Pan/Tilt & Fixed Dome Series. Installation Guide

Outdoor Enclosure. VIVOTEK Pan/Tilt & Fixed Dome Series. Installation Guide VIVOTEK Pan/Tilt & Fixed Dome Series Outdoor Enclosure Using AE-131/-132 Outdoor Enclosure, AE-151 Outdoor Enclosure, AM-114 Pendant Head (outdoor), AM-116 and AM-117 Pendant Pipes, AM-221 Gooseneck, AM-212

More information

Section 11 CABLE & ROD SYSTEMS, SIGN FIXING & SIGN STANDOFFS. Web. acrylicdesign.ie .

Section 11 CABLE & ROD SYSTEMS, SIGN FIXING & SIGN STANDOFFS. Web. acrylicdesign.ie  . Section 11 CABLE & ROD SYSTEMS, SIGN FIXING & SIGN STANDOFFS Web. acrylicdesign.ie Email. sales@acrylicdesign.ie Acrylic Design 2004-2015 Mobile Cable System Components Single panel clamp Stand Off for

More information

Rigid PVC Conduit Fittings Injection Molded in Sizes 1/2-6

Rigid PVC Conduit Fittings Injection Molded in Sizes 1/2-6 Rigid PVC Conduit Fittings Injection Molded in Sizes / - E Royal Building Products offers a complete line of rigid PVC conduit fittings. Royal s non-metallic conduit and fittings are certified by the CSA

More information

Marshall Tufflex. Cable Management. Steel Trunking Systems

Marshall Tufflex.  Cable Management. Steel Trunking Systems Marshall Tufflex Cable Management www.marshall-tufflex.com Steel Trunking Systems Steel Trunking Systems from Marshall Tufflex Steel perimeter trunking systems from Marshall-Tufflex Steel has a mechanical

More information

V00029KX READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID

V00029KX READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID Net-Verse D-Type Cabinets Tool List 10mm Socket Wrench 122mm (48 ) Level 19mm Wrench 8mm Hex Drive T25 Torx driver Net-Verse D-Type

More information

Rigid PVC Conduit Fittings Injection Molded in Sizes 1/2-6

Rigid PVC Conduit Fittings Injection Molded in Sizes 1/2-6 Rigid PVC Conduit Fittings Injection Molded in Sizes / - Royal Building Products offers a complete line of rigid PVC conduit fittings. Royal s non-metallic conduit and fittings are certified by the CSA and

More information

Installation Instructions

Installation Instructions Rev C, April 2018 Installation Instructions STANDARD DENSITY (SD) Shelf Sliding and Fixed Versions General The COMMSCOPE SD 1U and 2U fiber optic combination shelves come equipped with a modular faceplate.

More information

LF Series Assembly Instructions

LF Series Assembly Instructions LF Series Assembly Instructions 1998760 Revision A-10 Complete Series Master Packet 2010 Kimball International, Inc. T 800.482.1818 F 812.482.8300 Footprint Storage and Metal Filing Systems Assembly Instructions

More information

Installation Guide for PermaSnap Plus Coping

Installation Guide for PermaSnap Plus Coping Installation Guide for PermaSnap Plus Coping 4 COMMERCE WAY, ARDEN, NC 28704 USA 800.892.9173 828.676.1700 OMGEDGESYSTEMS.COM PermaSnap Plus Coping Reference Guide 1. Standard Installation Steps Page 3

More information

FHD-FMT Fiber Enlcosures

FHD-FMT Fiber Enlcosures .COM 2016 O INTALLATION INTRUCTION HD-MT iber Enlcosures Part Numbers: HD-1UMT-N HD-1UMT-N CAUTION: iber optic cable is sensitive to excessive pulling, bending, and crushing forces. WARING: UNMATED CONNECTOR

More information

Horizontal Cable Systems

Horizontal Cable Systems ALUMINUM RAILING INSTALLATION INSTRUCTIONS v2012 orizontal Cable Systems 1) Check Contents Of Packages: Verify that all parts have arrived and that they match the packing list. 1A) Coastal applications:

More information

INSTALLATION GUIDE. Model:B60 RECESSED IN WALL MOUNT

INSTALLATION GUIDE. Model:B60 RECESSED IN WALL MOUNT INSTALLATION GUIDE Model:B60 RECESSED IN WALL MOUNT Features: Installs between 16 (406mm) wood stud centers Mounting Pattern Compliance: VESA 100*100mm up to 600 x 400mm Level 5 degree horizontal adjustment

More information

SPG+S27 PATENT GLAZING. SPG+S27 Series Product Assembly Manual 1999

SPG+S27 PATENT GLAZING. SPG+S27 Series Product Assembly Manual 1999 SPG+S27 PATENT GLAZING SPG+S27 Series Product Assembly Manual 1999 4.1.ii 03.99 SPG and S27 Patent Glazing Introduction The Company Senior Aluminium Systems are a group of companies based in the United

More information

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000 INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000 Specifications: Accomodates Akira and Orion 84" displays without interface bracket; accomodates other large flat panel displays with

More information

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B 7878 K940 Checkpoint Antenna Kit Instructions Issue B Revision Record Issue Date Remarks A July 7, 2009 First issue B Nov2013 Revised the Checkpoint installation procedures for 7878 and 7874 scanners Added

More information

Horizontal Cable Systems

Horizontal Cable Systems ALUMINUM RAILING INSTALLATION INSTRUCTIONS Horizontal Cable Systems 1) Check Contents Of Packages: Verify that all parts have arrived and that they match the packing list. 1A) Coastal applications: Confirm

More information

PVC RAILING PVC RAILING BUILD SOMETHING BETTER

PVC RAILING PVC RAILING BUILD SOMETHING BETTER PVC RAILING PVC RAILING BUILD SOMETHING BETTER 2 DELUXE SERIES TRADITIONAL RAIL DECKORATORS SCENIC CLEAR VIEW GLASS BALUSTER (LEFT) AND CLASSIC SERIES TRADITIONAL RAIL DECKORATORS BLACK CLASSIC BALUSTER

More information

INSTALLATION INSTRUCTIONS MSP-SPFB (PFB-2000S) Plasma Floor Stand

INSTALLATION INSTRUCTIONS MSP-SPFB (PFB-2000S) Plasma Floor Stand INSTALLATION INSTRUCTIONS MSP-SPFB (PFB-2000S) Plasma Floor Stand Chief s Plasma Floor Stand is a safe, stable, easy-toinstall modular design solution for digital signage and presentations. Ideal where

More information

Post & Rail. Includes: Crossbuck, 2-Rail, 3-Rail and 4-Rail POST SUPPORT OPTIONS

Post & Rail. Includes: Crossbuck, 2-Rail, 3-Rail and 4-Rail POST SUPPORT OPTIONS Post & Rail Includes: Crossbuck, 2-Rail, 3-Rail and 4-Rail STAGGER RAIL ENDS FOR GREATER STRENGTH ALLOW 1-1/2" GAP ON HINGE SIDE OF GATE AND 1-1/4" ON LATCH SIDE OF GATE HARDWARE DIG HOLES 30" MINIMUM

More information

INSTALLATION INSTRUCTION Solorail - Low Voltage Starter Kit

INSTALLATION INSTRUCTION Solorail - Low Voltage Starter Kit IMPORTANT SAFETY INSTRUCTIONS: Read all instructions. Turn off power at main switch before installing or modifying the system. Do not install the system: - Within six inches of any curtain or combustible

More information

WIREMOLD AL7450 Series Isoduct Aluminum Raceway

WIREMOLD AL7450 Series Isoduct Aluminum Raceway Three-Channel, Dual-Cover, Prewired Aluminum Raceway System Isoduct AL7450 Series Raceway is a costeffective, highly aesthetic solution for providing access to communication cabling and electrical wiring

More information

Distributed Design Series

Distributed Design Series APPLICATIONS Convention centers, exhibit halls Corporate training rooms, ballrooms Athletic venues, sports facilities, health clubs Houses of worship Malls, airports FEATURES High intelligibility with

More information

The First Layer of Light. Indirectly. APPLICATION GUIDE

The First Layer of Light. Indirectly. APPLICATION GUIDE The First Layer of Light. Indirectly. Next-Generation Indirect Lighting Typical cove lighting Less than 50% of the light exits the cove. Even with an aimable luminaire, only 60% of the light exits the

More information

Revised

Revised Indentify Non-powered panels and separate from Powered panels. Non-powered panel shown at left.. Powered panel shown at left has powerway mounted at factory. Also separate panels by surface type, width

More information

table of contents Sliding Door Accessories Page Latches & Snuggers Stay Rollers Brackets & Stops

table of contents Sliding Door Accessories Page Latches & Snuggers Stay Rollers Brackets & Stops table of contents Square Track & Accessories Pages 4-7 Square Track Options Page 4 Light Duty Track Page 4 Square Track Brackets Page 5 Square Track Accessories Page 5 Square Track Trolleys Page 6-7 Offset

More information

FORMATIONS Curves Clouds with AXIOM VECTOR Trim and Suspension System

FORMATIONS Curves Clouds with AXIOM VECTOR Trim and Suspension System FORMATIONS Curves Clouds with AXIOM VECTOR Trim and Suspension System Assembly and Installation Instructions 1. DESCRIPTION 1.1 Formations Curves is a ceiling cloud system designed to create ready-to-assemble

More information

Installation Instructions

Installation Instructions Installation Instructions For Models: Model Number / Description File Name 1540 Classic Series P-Lam Toilet Partitions 1540.pdf 1 INSTALLATION INSTRUCTIONS LAMINATED PLASTIC TOILET PARTITIONS 1540 Classic

More information

CMS 603DC. Technical Data Sheet

CMS 603DC. Technical Data Sheet CMS 63DC Product description The Tannoy CMS 63DC is a full bandwidth, high power-handling and high sensitivity loudspeaker built around CMS 3. the third generation of Tannoy s revolutionary Ceiling Monitor

More information

CMS 803DC. Technical Data Sheet

CMS 803DC. Technical Data Sheet CMS 83DC Product description The Tannoy CMS 83DC is a full bandwidth, high power-handling and high sensitivity loudspeaker built around CMS 3. the third generation of Tannoy s revolutionary Ceiling Monitor

More information

Workstation Selection Guide

Workstation Selection Guide Workstation Selection Guide visit www.panduit.com 1 An Extensive Selection of Workstation Products to Support Your Applications Panduit provides enterprise solutions that satisfy current voice, data and

More information

Setup. The Faraday Cage is available in two types of configurations. Cage for mounting to a full perimeter enclosure on series tables.

Setup. The Faraday Cage is available in two types of configurations. Cage for mounting to a full perimeter enclosure on series tables. Faraday CageSetup, 2017 Setup The Faraday Cage is available in two types of configurations. Cage for mounting to a full perimeter enclosure on 63-500 series tables. Cage with a base plate for use on a

More information

Distributed Design D SERIES D6 TWO-WAY 6.5-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

Distributed Design D SERIES D6 TWO-WAY 6.5-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS APPLICATIONS Convention centers, exhibit halls Corporate training rooms, ballrooms Athletic venues, sports facilities, health clubs Houses of worship Malls, airports Nightclubs, bars, restaurants The is

More information

LED Neon Light Round

LED Neon Light Round LED Neon Light Round Part #: NEON -P RND HB 24VDC WHT lc con cab LED Neon Light Round SPECIFICATION 36 21.5 19.5 HORIZONTAL BEND 46.5 CST Length CST Custom Length 3 cuttable every 3.25 Operating Voltage

More information

600G2 Internal Sliding Adapter Panel Shelf Instructions

600G2 Internal Sliding Adapter Panel Shelf Instructions Instruction Sheet 860391986 Issue 6, February 2013 SYSTIMAX Solutions 600G2 Internal Sliding Adapter Panel Shelf Instructions General The SYSTIMAX 600G2 adapter panel shelf is 19-inch wide x 1.75-inch

More information

COWO. Customer Wall Outlet. 1 General. 2 Kit content. 3 Handling of the box. TC-1203-IP Rev A, Apr

COWO. Customer Wall Outlet. 1 General. 2 Kit content. 3 Handling of the box. TC-1203-IP Rev A, Apr COWO I N S T A L L A T I O N I N S T R U C T I O N TC-1203-IP Rev A, Apr 2017 www.commscope.com Customer Wall Outlet 1 General Customer Wall Outlet 2 Fiber for max. 2 bend reduced fibers, 2 SC-adapters

More information

compile system INSTALLATION GUIDE Updated January 2019

compile system INSTALLATION GUIDE Updated January 2019 INSTALLATION GUIDE Updated January 09 compile system Table of Contents Panels 0 Quick Connect Clips 0 Lock Clips 0 Panel Trims 0 Privacy Glass 0 Post Base Covers 04 Electrical 04 Power Distribution Harness

More information

System 3000 specifications

System 3000 specifications System 3000 specifications Scope: Materials: Type of Bookstack: This specification covers delivery and installation of steel library shelving of the bracket type. Height, depth and accessories shall be

More information

WALL SHELVING SYSTEM 250/750

WALL SHELVING SYSTEM 250/750 468 2/7 Installation Example Ceiling Height (CH) : 2800 mm Ceiling Height (CH) : 28 mm Corner Installation 2 design panels are used to cover mm space in case of ceiling height 28 mm. Corner Example 469

More information

DUALCASE VERSATILE ALUMINIUM SIGN SYSTEM

DUALCASE VERSATILE ALUMINIUM SIGN SYSTEM VERSATILE ALUMINIUM SIGN SYSTEM Universal Components Ltd. May 2007 Introduction Nothing beats DualCase for speed of fabrication, aesthetic appearance and easy maintenance. With the minium of components

More information

Communications Integrators, Inc. June S. Wilson Street, Suite 105 Tempe, Arizona Toll Free (800) Web Site

Communications Integrators, Inc. June S. Wilson Street, Suite 105 Tempe, Arizona Toll Free (800) Web Site Communications Integrators, Inc. June 2008 2625 S. Wilson Street, Suite 105 Tempe, Arizona 85282 Toll Free (800) 679-9711 Web Site www.ciinet.com Product Guide Specification Specifier Notes: This product

More information

The V2100 Series Steel Raceway provides wiring

The V2100 Series Steel Raceway provides wiring V2100 Steel Raceway Two-Piece Surface Raceway The V2100 Series Steel Raceway provides wiring capacities for small to medium size installations. Power or Data/Communication Devices can be wired into the

More information

Trunking Guide. Colour List... W White M Magnolia B Black. shape & size (wxh) colours available

Trunking Guide. Colour List... W White M Magnolia B Black. shape & size (wxh) colours available Trunking Guide Colour List... W White M Magnolia B Black A Aluminium O Oak Effect R Red P Premium Wood (stainable 22x22 only) F1 Light Oak Effect (22x22 only) illustrations not to scale shape & size (wxh)

More information

Manchester Vinyl Picket Gate with Posts (42 Wide x 42 Tall)

Manchester Vinyl Picket Gate with Posts (42 Wide x 42 Tall) ASSEMBLY INSTRUCTIONS Manchester Vinyl Picket Gate with Posts (4 Wide x 4 Tall) /4 in / in 4 in 6 in 45 /8 in 4 in 8 in 4 / in Gate Opening in Ground 49 / in Outside Posts This Gate is designed to be integrated

More information

INSTALLATION INSTRUCTIONS Horizontal And Vertical Table Stands and Accessories Model: KTP-Series

INSTALLATION INSTRUCTIONS Horizontal And Vertical Table Stands and Accessories Model: KTP-Series INSTALLATION INSTRUCTIONS Horizontal And Vertical Table Stands and Accessories Model: KTP-Series The KTP-Series is a free standing, pole mount solution for multiple displays. KTP-320 KTP-220 / KTP-225

More information

Instructions and Parts List MSS-12W MARTIN SAFETY SYSTEM

Instructions and Parts List MSS-12W MARTIN SAFETY SYSTEM HOUSE PARTS PACKED IN HOUSE BOX Code # Item Qty Description 950 9776 77 85036 500 868 635 9635 5075 860 3578 8507 60 6 95065 6 98000 7800 7806 3 5 6 7 7A 8 9 0 3 5 6 6A 6B 8 Instructions and Parts List

More information

General-Purpose Photoelectric Sensor

General-Purpose Photoelectric Sensor General-Purpose Photoelectric Sensor Wide Selection of High Performance Small DC Sensors Offers Longer Sensing Distances Fast 0. msec response time for high-speed sensing Extended sensing distances up

More information

PATENTED NO WELD SYSTEM!

PATENTED NO WELD SYSTEM! PATENTED NO WELD SYSTEM! Patented no weld aluminium batten system Various batten sizes snap onto simple fixing clip Fit to face of walls and ceilings or between pillars or posts Cut to size system with

More information

Height Adjustable Benching End Panel and Utility Pole

Height Adjustable Benching End Panel and Utility Pole Height Adjustable Benching End Panel and Utility Pole Tools required: END PANEL Jig Saw Power Drill END PANEL WITH UTILITY POLE Bit Holder Long #2 Square Drive Bit 5mm Hex Drive Bit UTILITY POLE Level

More information