1 Model General Specification Features! Reliableno moving parts, no fluid to sensor contact! In-process removable sensor, below 750 psig (52 barg) pressure! Simple, rugged, all welded construction, no internal gaskets, no leak paths! High accuracy with wide rangeability! Line sizes from 1" to 12" ( mm )! High temperature operation up to 750 F (400 C)! EZ Logic menu-driven user interface! Smart electronics provide excellent noise immunity! Compatible with HART Protocol! Optional Dual sensors and transmitters for fail-safe monitoring The EMCO vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fl uid line (the bluff body). A piezo-electric sensor mounted outside the fl ow line acts as the transducer, converting vortex pulses into electrical signals. The Smart electronics provide excellent noise immunity while the wide range of wetted materials provide outstanding compatibility with most process fl uids. The transmitter provides a frequency output, scaled frequency output, totalizer pulse or a 4-20 ma DC signal proportional to the fl ow rate. (303) Fax (303) sales@emcoflow.com
2 Performance Specifications Accuracy Liquid... ± 0.7% of fl ow rate Gas and Steam... ± 1.0% of fl ow rate Analog Output Version... Add ± 0.1% of full scale Repeatability ± 0.15% of fl ow rate Operating Specifications Fluid Types Liquid, gas or steam Line Sizes 1" 12" ( 25mm to 300mm ) Process Temperature Limit 40 to 750 F ( 40 to 400 C ) Process Pressure Flange ANSI Class 150, 300 or 600, PN16, 40, 64 Wafer All wafer bodies are rated based on appropriate fl ange rating to a maximum of ANSI Class 600 Enclosure Specifications Approved for NEMA 4X watertight and dust tight requirements. Ambient Temperature Limit Normal 20 to 140 F ( 29 to 60 C) Display Option F (0 60 C) AMBIENT TEMPERATURE F ( C) 180 (82) 150 (66) 140 (60) 110 (43) 70 (22) Response Time Adjustable from seconds (analog version output) K-factor Temperature Correction The K-factor of the fl owmeter decreases by 0.29% for each 100 F (39 C) increase in temperature above 70 F (21 C). The converse is true below 70 F (21 C). By programming the operating fl uid temperature in the electronics, the change in the K-Factor is automatically corrected for. Output Analog 4 20 ma, loop powered 2 wire system, digitally adjusted span Frequency Voltage pulses, 3 wire system, 1 to 10 khz square wave, open collector FET output with selectable pull-up resistors. The pulse output can be scaled so that 1 pulse represents a specifi c quantity of fl uid passing through the fl owmeter. For typical applications, the amplitude of the squarewave can be determined by: V pulse =V s (I R load ) For other options refer to the manual Span Setting For analog outputs the span setting can be adjusted without the use of electronic test equipment by programming the full scale rate using the EZ Logic kepyad. HART Protocol In addition to using the keypad for fi eld confi guration, the is also compatible with a laptop PC using a Hart Modem and EMCO EZ Comm communications software. This can be used to calibrate the 4-20 ma settings, set the 20 ma point, assign a tag or descriptor, display fl owrate, output level, total, velocity and shedding frequency. Cable Conduit Connection ANSI 3/4" female NPT. See Dimensions. ( p. 9 ) DIN PG See Dimensions. ( p. 9 ) Signal Cable 18, 20 or 22 gauge, shielded instrumentation cable. Belden #9939 double shielded cable or equivalent required for European CE rating. 32 (0) -100 (-73) -20 (-29) 100 (38) 300 (149) PROCESS TEMPERATURE F ( C) 500 (260) Measurable Flow Velocities Liquid 1.5 to 32 ft/sec (0.5 to 9m/sec) Figure 1. Ambient Temperature Range for Locally Mounted Electonics. Ambient Humidity Limit 5 100% RH non-condensing Power Requirements VDC; max power consumed: 1 watt Gas/Steam 50 ρ Where: to 260 ft / sec ρ to m / sec ρ = density in lb kg 3 ft 3 m Process Viscosity Reynolds number must be >: 20,000 (See Figure 3) Linear Range Reynolds Numbers of 20,000 to 7,000,000 2
3 Minimum Flow Velocity m/s ft/s " " 40 2" 50 3" 80 4" 100 6" 150 8" " " Kinematic Viscosity (centistokes) Figure 3. Minimum Linear Flow Velocity vs. Kinematic Viscosity. NOMINAL SIZE NOMINAL NOMINAL METER FACTOR PULSE RATE inch mm Hz/ft/s Hz/m/s pulses/gal pulses/l pulses/ft 3 pulses/m ,403 84, , , , , Table 1. Nominal Pulse Rate and Flowmeter Factor. NOMINAL SIZE FLOW RANGE FLOW RANGE in GPM in L/s inch mm min max min max , , , , , Table 2. Water Flow Rates. Notes: 1 Water values are determined at standard conditions of 60 F (15 C). 2 The minimum fl ow rate for the 1" (25 mm), and 1.5" (40 mm) fl owmeters are below the linear range the Reynolds number < 20,000). 3 The velocities used to calculate the minimum and maximum fl ow rates were 1.5 ft/sec and 32 ft/sec (0.5 m/sec and 9 m/sec) respectively. For EMCO Flowmeter Sizing Download emcosizing program "emcosize" at Flowmeter Sizing Selecting the appropriate size fl owmeter can be critical. If the fl owmeter is over-sized, the signal strength could be weak limiting rangeability. If the fl owmeter is undersized, excessive pressure drop or cavitation may occur affecting accuracy. Use the minimum linear fl ow velocity curves and Tables 2 through 8 (minimum and maximum fl ow rates for various types of applications) for general sizing. For more detailed information, contact your EMCO representative or go to for EMCO computerized sizing program. Pressure Loss If a differential pressure transducer were connectd between pressure taps up and downstream of a vortex fl owmeter, the measured differential pressure would be the pressure loss for the device. This value can be calculated using the following equations: English... P = 2.67 x 10-4 ρ V 2 or... P = 2.50 x 10-3 ρ (Q 1 ) 2 / D 4 or... P = 4.47 x 10-5 ρ (Q 2 ) 2 / D 4 Metric... P = 1.24 x 10-5 ρ V 2 or... P = 5572 ρ (Q 1 ) 2 / D 4 or... P = 20.1 ρ (Q 2 ) 2 / D 4 Where: P = Pressure loss psi (bar) ρ = Density at operating conditions lb/ft 3 (kg/m 3 ) V = Flow velocity in ft/s (m/s) Q 1 = Volumetric fl ow rate in ACFM (Actual m 3 /min) Q 2 = Volumetric fl ow rate in U.S. GPM (L/s) D = Flowmeter internal diameter in inches (mm) Minimum Back Pressure (Liquid Service Only) The line pressure must be suffi ciently high so that no cavitation occurs. The minimum required line pressure can be obtained from the equation: PG ( 1 3 P o ) ( 2.7 P ) - P ATM Where: P G = Line pressure required psig (barg) P = Maximum pressure loss psig (barg) P o = Saturation liquid vapor pressure at operating temperature psia (bara) P ATM = Atmospheric pressure psia (bara) Example: Water fl ow rate: 0 to 200 US GPM Operating temperature: 100 F Operating pressure: 10 psig Atmospheric pressure: 14.7 psia Flowmeter size: 1.939" I.D. Specifi c weight: lb/ft 3 Solution: P = 4.47 x (200) 2 /(1.939) 4 = 7.84 P G = [(1.3) (0.951)] [(2.7) (7.84)] P G = 7.70 psig Since the operating pressure of 10 psig is higher than 7.70 psig, no cavitation occurs. 3
4 Physical Specifications Materials Wetted Parts Wing and Shedder Bar Stainless steel and Carbon steel Models 316L or the cast equivalent, CF3M Body Hastelloy Model Hastelloy Alloy C-22 Stainless steel Model (all sizes) 316L or the cast equivalent, CF3M Hastelloy Model 1" thru 4" (25mm thru 100mm) Hastelloy Alloy C-22 Carbon Steel Model (fl anged), 6" (150mm) and larger ASTM A105, A06 Grade C, and A108 Grade 1018 Electronics Enclosure 383 Aluminum All Other Parts Stainless Steel Flowmeter Classification Standard Designed to meed NEMA 4X watertight and dust tight specifi cations Explosion Proof version FM and CSA approved Explosion Proof and Intrinsically-Safe version CENELEC approved Remote Mount Electonics (RMT) Signal cable is provided to mount the electronics enclosure up to 30 ft (optional 50 ft) from the flowmeter body, and must be installed within proper electrical conduit. Local Indicator and Totalizer (LOC-TOT) The indicator displays fl owrate and total in user-selectable, engineering units. It is a two line, 8 character per line, LCD display. The totalizer enables a pulse output providing a msec pulse each time the totalizer increments. Note: This option changes the lower, ambient temperature limit to 32 F (0 C). Below 32 F, the display intensity begins to fade but doesn not affect the transmitter output. Material of Construction All models are available in stainless steel; some models can be ordered in Hastelloy C-22 or carbon steel. FM Approval (Explosion Proof) Class I, Div. I, Groups B, C, D Class II, Div. I, Groups E, F, G Class I, Div. II, Groups A, B, C, D Class II, III, Div. 2, Groups F, G CSA Approval (Explosion Proof) Class I, Div. I, Groups B, C, D Dust-ignition Proof for Class II, Div. 1 Groups E, F, G Class III Hazardous locations CENELEC Approval (Explosion Proof and Intrinsically Safe) EEX d [ib] IIC T6 and/or EEX d IIC T6. European CE Mark Approved 4
5 Accessories Flow Rectifier (EFR) When there is not sufficient straight run of pipe available or fl ow disturbance exists, use of a fl ow rectifier is recomended. When using an EFR, the straight pipe run can be a combination of 5 pipe diameters upstream and 2 pipe diameters downstream, instead of the standard 10 and 5. Flow Processor A microprocessor-based fl ow processor can be used to significantly increase the accuracy and functionality of any fl owmetering application. See the FP-93 or FP-100 General Specifications for complete details. Straight Run Piping Requirements Typical 10 diameters upstream, 5 diameters downstream. In certain applications where multiple bends or butterfl y valves are present, more straight run may be required. One 90 elbow before the meter Two 90 elbows before the meter Two 90 elbows out before the meter of plane Reduction before the meter Regulator or valve before the meter partially closed Upstream Downstream 10 D 5 D 15 D 5 D 30 D 5 D 10 D 5 D 30 D 5 D Other Installation Considerations Installation Flowmeter can be installed vertically, horizontally, or at any angle. For liquid service, the fl ow line must be full during fl owmeter operation fl ow up in vertical lines is recommended. Pressure and Temperature Taps Pressure tap should be mounted 3.5 to 7 pipe diameters downstream from the fl owmeter. The temperature tap should be mounted an additional 3.5 to 7pipe diameters downstream of the pressure tap. See Figure 2. Site Selection The fl ow measurement location should be selected to minimuze turbulence and swirl. the extent of these fl ow disturbances depends upon the piping condiguration. Valves, elbows, pumps and other piping compnents may add disturbances to the fl ow. Servicability The sensor element can be removed, and replaced, without removing the fl owmeter body from the process line, and without process shut down for process pressures below 750 psig (52 bar). Thefl owmeter K-factor is not affected by sensor or electronics servicing. The Dual option allows service of one sensor and electronics while the other transmitter provides continuous fl ow measurement. FLOW gal/min 3.5 to 7 internal diameters Pressure Transmitter 3.5 to 7 internal diameters Temperature Transmitter Figure 2. Pressure and Temperature Tap Dimensions. 5
6 1" 1.5" 2" 3" 4" 6" 8" 10" 12" Pres PSIG min max min max min max min max min max min max min max min max min max Table 3. Saturated Steam Flow Rates at Selected Process Pressures (English). 1,2 (Minimum and Maximum Operating Flow Rates in lb/hr) For EMCO Flowmeter Sizing Download emcosizing program "emcosize" at 25mm 40mm 50mm 80mm 100mm 150mm 200mm 250mm 300mm Pres BARG min max min max min max min max min max min max min max min max min max Table 4. Saturated Steam Flow Rates at Selected Process Pressures (Metric). 1,2 (Minimum and Maximum Operating Flow Rates in kg/hr) For EMCO Flowmeter Sizing Download emcosizing program "emcosize" at Notes: 1 Maximum fl ow velocity is 260 ft/sec (79 m/s) or Reynolods number limit or 7,000,000 whichever is less Minimum fl ow velocity is ft whereρ density in lb 74 /sec, = m/sec, where ρ = density in kg 3 3 ρ ft ( ρ ) m or Reynolds number limit of 20,000 whichever is greater. 6
7 1" 1.5" 2" 3" 4" 6" 8 10" 12" Pres PSIG min max min max min max min max min max min max min max min max min max Table 5. Air Flow Rate at Selected Process Pressures (Metric). 1,2,3 (Minimum and Maximum Operating Flow Rates in SCFH) For EMCO Flowmeter Sizing Download emcosizing program "emcosize" at 25mm 40mm 50mm 80mm 100mm 150mm 200mm 250mm 300mm PresBARG min max min max min max min max min max min max min max min max min max Table 6. Air Flow Rate at Selected Process Pressures (Metric). 1,2,3 (Minimum and Maximum Operating Flow Rates in NCMH) For EMCO Flowmeter Sizing Download emcosizing program "emcosize" at Notes: 1 At standard conditions of 60 F and 14.7 psia, SCFH: standard cubic feet per hour (0 C and bar, NCMH: Normal cubic meters per hour). Process temperature is 60 F (16 C). 2 Maximum fl ow velocity is 260 ft/sec (79 m/s) or Reynolods number limit or 7,000,000 whichever is less Minimum fl ow velocity is ft whereρ density in lb 74 /sec, = m/sec, where ρ = density in kg 3 3 ρ ft ( ρ ) m or Reynolds number limit of 20,000 whichever is greater. 7
8 1" 1.5" 2" 3" 4" 6" 8 10" 12" Pres PSIG min max min max min max min max min max min max min max min max min max Table 7. Natural Gas Flow Rates at Selected Process Pressures (English). 1,2,3,4 (Minimum and Maximum Operating Flow Rates in SCFH) For EMCO Flowmeter Sizing Download emcosizing program "emcosize" at 25mm 40mm 50mm 80mm 100mm 150mm 200mm 250mm 300mm PresBARG min max min max min max min max min max min max min max min max min max Table 8. Natural Gas Flow Rates at Selected Process Pressures (Metric). 1,2,3,4 (Minimum and Maximum Operating Flow Rates in NCMH) For EMCO Flowmeter Sizing Download emcosizing program "emcosize" at Notes: 1 At standard conditions of 60 F and 14.7 psia, SCFH: standard cubic feet per hour (0 C and bar, NCMH: Normal cubic meters per hour). Process temperature is 60 F (16 C). 2 Maximum fl ow velocity is 260 ft/sec (79 m/s) or Reynolods number limit or 7,000,000 whichever is less. 3 Specific Gravity of natural gas = 0.61 and 0.8% N 2. 4 Minimum fl ow velocity is 50 ft whereρ density in lb 74 /sec, = m/sec, where ρ = density in kg 3 3 ρ ft ( ρ ) m or Reynolds number limit of 20,000 whichever is greater. 8
9 EMCO Dimensions and Weights 1.00" (25 mm) 4.50" (114 mm) 3.12" (79 mm) 3.62" (92 mm) Wafer Connection Wafer connection is available in stainless steel (sizes 1 4" only) and Hastelloy (sizes 1 3"only). The schedule of the mating pipe's internal diameter dimension "D". 4.90" (124 mm) SIZE A B C D APPROX WT (in) (in) (in) (in) (in) (lb) A MAX. 3/4" NPT (PG 13.5) EMCO B Table 9. English Weights & Dimensions: Wafer D Figure 4. Dimensions and Weights: Wafer Connection Type, Integral Mounting. C SIZE A B C D APPROX WT (mm) (mm) (mm) (mm) (mm) (kg) Table 10. Metric Weights & Dimensions: Wafer Pipe Mount Electronics OR Wall Mount Electronics Note: For best results mount remote transmitter below horizontal pipe. 5" (127 mm) Dia " (7.14 mm) 6.5" (165.1 mm) 0.4" (10.2 mm) 4.20" (106.7 mm) 8.5" (215.9 mm) 5" (127 mm) 8.5" (215.9 mm) 8.5" (215.9 mm) 7.70" (195.6 mm) 5" 5" (127 mm) 0.4" (10.2 mm) APPROXIMATE WEIGHT (lb) 150# Flange 300# Flange 600# Flange Wafer size (in) Std Dual Std Dual Std Dual Std N/A N/A N/A N/A APPROXIMATE WEIGHT (kg) PN 16 Flange PN 40 Flange PN 64 Flange Wafer size (mm) Std Dual Std Dual Std Dual Std N/A N/A N/A N/A Figure 5. Dimensions and Weights: Remote Mounting. 9
10 Dimensions and Weights 3.12" (79 mm) 3.62" (92 mm) 1.00" (25 mm) 4.50" (114 mm) 4.90" (124 mm) 3/4" NPT (PG 13.5) Display (Optional) A MAX. EMCO B C Figure 6. Dimensions & Weights: Flange Connection, Integral Mounting. all in A B C Approx. Wt. (lb) inches Stainless Steel Carbon Steel Hastelloy size 150# 600# 150# 600# 150# 150# 300# 600# 300# 300# 300# 600# N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A C/F C/F C/F C/F Table 11. English Weights & Dimensions: Flange. all in A B C Approx. Wt. (kg) mm Stainless Steel Carbon Steel Hastelloy size PN 16 PN 64 PN 16 PN 64 PN 16 PN 16 PN 40 PN 64 PN 40 PN 40 PN 40 PN N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A C/F C/F C/FV C/F Table 12. Metric Weights & Dimensions: Flange. Notes: 1 The schedule of the mating pipe's internal diameter dimension C. 2 N/A = Not Available, C/F = Consult Factory. 10
11 Dimensions and Weights 1.00 (25 mm) 4.50 (114 mm) 3/4" NPT (PG 13.5) (79 mm) (92 mm) 4.90 (124 mm) 3/4" NPT (PG 13.5) A (Max.) FLOW C The number of bolt holes and their diameter depend upon ANSI or DIN standard. B Figure 7. Dimensions & Weights: Dual Style. all in A B C C C Approx. Wt. (lb) inches Stainless Steel Carbon Steel Hastelloy size 150# 300# 600# 150# 600# 150# 600# 150# 150# 300# 600# 300# 300# 300# 600# N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A C/F C/F C/F C/F Table 13. English Weights & Dimensions: Dual. all in mm A B C C C Approx. Wt. (kg) Stainless Steel Carbon Steel Hastelloy size PN 16 PN 40 PN 64 PN 16 PN 64 PN 16 PN 64 PN 16 PN 16 PN 40 PN 64 PN 40 PN 40 PN 40 PN N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A C/F C/F C/F C/F Table 14. Metric Weights & Dimensions: Dual. Notes: 1 The schedule of the mating pipe's internal diameter dimension C. 2 N/A = Not Available, C/F = Consult Factory. 11
12 Wiring Figures 8 10 represent typical fi eld wiring applications for the. Analog Output The may be operated using a 24 VDC power supply. The 4-20 ma output is scalable (2 wire principle.) The load resistor may be installed on supply or return line. Permissible load resistance values are shown in Figure 8. MAX. LOAD RESISTANCE (Ω) LOAD = 50 (Vs 18) Without LOCTOT Option With LOCTOT Option Permissable Load Resistance Range POWER SUPPLY VOLTAGE (VDC) P Rload Vs (18-40 VDC) Figure ma Output. Pulse Output This is an open collector pulse output using a high impedance electronic counter. V pulse will vary from: R C 0 1V to Vpulse = VS RC R pulse Note: VS Rpulse 0.16 Where: V pulse = pulse output amplitude R C = counter impedance V S = power supply voltage = minimum required voltage to trip counter V C P Vpulse Figure 9. Pulse Output. Rpulse Vs (18-40 VDC) 12
13 Wiring Cenelec ApprovedPower & Signal Wiring The fl owmeter may be operated using a 24 VDC power supply. The wiring schematic shown is for the areas defi ned by the Cenelec approval (see approval description in options section). I. S. zener barriers must have the following specifications: V max = 29 VDC = Maximum voltage which may be connected to barrier terminals J max = 110 ma = Maximum current which may be connected to barrier terminals C int = 1.5 nf = Maximum equivalent internal capacitance across barrier terminals L int = 0 H = Maximum equivalent internal inductance across barrier terminals The 4-20 ma output is scalable (2 wire principle.) The 4-20 ma loop resistor should be 250 Ω; and the pulse output is to be connected to a high impedance, electronic counter. V pulse varies from: 0-1 VDC to V pulse = V s ( Note: Rpulse V s 0.16 Where: V pulse = Pulse output amplitude V s = Power supply voltage (18 to 29 VDC) R load = Load resistance R c = Counter impedance R pulse = Pullup resistance R c R c R pulse) MAX. LOAD RESISTANCE (OHMS) Hazardous Area P LOAD = 50 (Vs 18) 18 Permissable Load Resistance Range POWER SUPPLY VOLTAGE (VDC) Safe Area or Zone 2 Zener Barrier R load R pulse V pulse Figure 10. CENELEC Approved (Intrinsically Safe). Vs ( VDC) 110/220 VACPower & Signal Wiring The fl owmeter may be operated using a 110/220 VAC power supply. The power supply board converts the 110/220 VAC to 24 VDC. The 4-20 ma output is scalable (2 wire principle.) The 4-20 ma loop resistor should be 250 Ω; and the pulse output is to be connected to a high impedance, electronic counter. (Figure 11) V pulse varies from 0 1 VDC to V pulse = 24 VDC (I R load ) Where: V pulse = Pulse output amplitude R load = Load resistance (250 Ω) I = Current (4-20 ma) L N GND AC ACC GND PULSE Analog () Analog () V pulse R load Figure 11. Frequency/4-20 ma Output Using 110/220 VAC Power. 13
14 EZ Logic Programming Map Customer Name FLUID: Exit No SavChng? Yes To Move Through Map 2 SEC 1. Use up/down and right arrows as shown in map 2. While in display menu hold down right arrow key for 2 sec. to go to programming menus 3. While in column headings press ENTER key to go to display menu. You will be prompted by "Exit?" and then "Sav Chg?". Display Menu Password gal/min x1 gal 10% To alter data 1. To alter data press ENTER key within selected block 2. Use up/down arrows to alter value 3. Use right arrow to move cursor position 4. To store data press ENTER Error code 4 Output Fluid Sensor Reset Service Password HART Display C menu C menu C menu C menu D menu D menu P menu P menu P Basic menu FlowRate Show Total Show BarGraph Show Err Code Show TotReset Yes Dsply TC 05 Sec Scan On ScanTime 05 Sec Flow Res 8 digits HART On Set Pass 0000 Sub Freq 0000 Hz 4-20 Out 0.000% Freq Out Hz Vor Ampl 0% Vor Freq 0 Hz 4 ma Cnt mA Cnt 7150 Version 3.00 Error code 1 Total Reset N Defaults No Pipe ID 1 in. Meter K WO# Tag # Density Ref Den Dens Rng 1.5 Viscos 1 cp Temp 0100 F 4-20 ma On 4-20 TC 05 sec Zero TM 0 sec Freq out Vor freq Work Order # Flw unit gal/min Tot unit x1 gal Max flow Min flow M-factor 0150 Noise Lv 003 % Direct Off Transit Puls unt ft 3 Per puls Pulse Puls unt ft 3 Per puls Puls wth 50 msec Pulse Puls unt ft 3 Per puls Puls wth 50 msec Vor freq Freq TC 05 Sec Scl freq Freq max 10 khz Freq TC 05 Sec Customer P.O. # Factory programmed to fit specific application. EZ Map Version # 14
15 Model and Suffix Codes CATEGORY DESCRIPTION SUFFIX CODES Model Stainless Steel (sizes 1 12") PhD Hastelloy (sizes 1 8") PhD Carbon Steel (Stainless steel wing) (sizes 6 12") PhD Fluid Steam or gas... S Type Liquid... L " " " " " " " " Line Size 12" mm DN mm DN mm DN mm DN mm DN mm DN mm DN mm DN mm DN Connection Wafer W Type Flange F ANSI Class ANSI Class Connection ANSI Class Rating DIN, PN PN DIN, PN PN DIN, PN PN No indicator/totalizer option STD... FM approved FM... CSA approved CSA... CENELEC approved CEN... Options Local Indicator and Totalizer LOC-TOT... Remote Mount Electronics RMT... Integral 110 VAC input Integral 220 VAC input Dual sensor and transmitter DUAL... Sensor Wires Teflon, 40 to 400 F (40 to 204 C) T (Internal) Fiberglass, 150 to 750 F (65 to 400 C) F Example Table 15. PhD Vortex Shedding Flowmeter. Notes: 1 Has 4-20 ma and/or 50% duty cycle frequency output. A 50% duty cycle frequency can be scaled. 2 FM and CENELEC approved meters come with a magnet wand. For all other meters the wand can be ordered as an option. 3 At least one local indicator is recommended at each site. If one display will be used on many meters, should be purchased separately. 4 Remote mount electronics are requried for high process temperatures (refer to the general specifi cation). The standard remote mount option comes with 30' of cable. 5 Not available with European CE Mark or FM, CSA and CENElEC approvals. 6 Wafer style meters available in stainless steel (sizes 1 4" only) and Hastelloy (sizes 1 3") only). (Not available with dual option). 7 Dual fl owmeter is not available with wafer connections or CSA approval. PhD-90-S-60-F-300-LOC-TOT-RMT-T Compatibility Chart Compatible Incompatible STD FM CSA CENELEC LOC-TOT RMT 110/220 DUAL CARBON STEEL HASTELLOY STAINLESS STEEL EUROPEAN CE MARK STD FM CSA CENELEC LOC-TOT RMT 110/220 DUAL CARBON STEEL HASTELLOY STAINLESS STEEL EUROPEAN CE MARK 15
16 Providing innovative flowmeter products and services for over three decades... (EMCO) is a long established manufacturer of precision fl owmeters for liquid, gas, and steam applications for commerce and industry. Manufactured under an ISO 9001 certifi ed quality system, which includes extensive fl ow calibration capability, engineering, applications, and service, underpining a world-wide sales and service organization totally focused on providing the best fl owmeters and customer service in the industry. 4 Manufacturing is housed in a modern plant located in Longmont, Colorado 4 Modern clean-room, mechanized assembly equipment, and computer based testing ensure the highest quality product 4 Trained professional flow specialists and technicians offer timely customer assistance 4 Factory trained and certified field technicians provide product support services V-Bar Insertion Vortex Inline Vortex Turbo-Bar Insertion Turbine MAGFLO Electromagnetic PDH Helix PDP Piston Sono-Trak P/N Rev.K Specifications subject to change without notice 600 Diagonal Hwy. Longmont, CO (303) Fax (303) sales@emcofl ow.com
PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications
Description The Vortex PhD vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fluid line (the bluff body). A
More informationModel Sono-Trak Transit Time
Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic
More informationRCM DIRECT READING FLOWMETER
RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:
More informationRosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS
Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationElectro-Magnetic Flowmeters COPA-XE
Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationFlow Level Temperature Pressure Valves Analyzers Accessories TekValSys
Technology Solutions www.tek-trol.com 796 Tek Drive Crystal Lake, IL 60014 USA Tel: +1 847 857 6076, +1 847 655 7428 Fax: +1 847 655 6147 Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys
More informationSVM 3000 PLUS Smart Vortex Flowmeter Specification and Application Data. 37-VM Rev /98
SVM 3000 PLUS Smart Vortex Flowmeter Specification and Application Data 37VM2901 Rev. 2.1 10/98 Copyright, Notices, and Trademarks Printed in U.S.A. Copyright 1998 by Honeywell Inc. Revision 2.1 10/98
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationField IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter
Data Sheet D-FMP-10D1475W-Y_4 Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter 10D1475W/Y Flowmeter Systems utilizes a smart microprocessor converter. System accuracy of ±0.5% of
More informationMagnetostrictive Level Transmitter
Magnetostrictive Level Transmitter The Model KMD is an advanced, state-of-the-art, two-wire, Magnetostrictive-based level transmitter suitable for a wide range of process applications. The latest in microprocessor
More informationAmbient Conditions. Operating Conditions. Pressure
Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version
More informationDigitalFlow TM CTF878
DigitalFlow TM CTF878 Panametrics Correlation Tag Clamp-On Gas Ultrasonic Flow Meter Applications The DigitalFlow CTF878 clamp-on gas fl ow meter is a complete ultrasonic fl ow metering system for the
More informationMass and Volume Flow Transmitter
IFT9701 Product Data Sheet PS-00218-EU December1999 Mass and Volume Flow Transmitter IFT9701 transmitter The IFT9701 microprocessor-based transmitter works with Micro Motion sensors to provide affordable,
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationFlow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.
Flow Technologies Overview Mag Flow MAGFLO Program Siemens offers a comprehensive selection of electromagnetic flow meters Water & waste water Chemical Food & beverage Mining Aggregates Cement Pharmaceutical
More informationDigital flowmeter for continuous flow measurement
8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration
More informationINSERTION paddle wheel flowmeter for continuous flow measurement
INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationUFM 800 W, C Ultrasonic flowmeter for water and wastewater
KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters
More informationDigital flow ELEMENT transmitter for continuous flow measurement
Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single
More informationTIDALFLUX 2300 F Technical Datasheet
Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to
More informationDigital flowmeter for continuous flow measurement
8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration
More informationSITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview
Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E
More informationKMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)
KMS502F Electromagnetic Flanged Flowmeters (sizes: 25mm to 200mm) FEATURES: For all your water applications including batching. Flanged connection suites ANSI 150lb flanges. Unsurpassed accuracy to ±0.5%
More informationPAD - Heavy Duty Differential Pressure Trasmitter
Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:
More informationModel 8800C and Model 8800A Smart Vortex Flowmeter English Rev. JA
Model 8800C and Model 8800A Smart Vortex Flowmeter 00809-0100-4003 English Rev. JA Product Manual Model 8800C and Model 8800A Smart Vortex Flowmeter NOTICE Read this manual before working with the product.
More informationKMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display
Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationTEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions
Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof
More informationSITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9
Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.
More informationFLOMID FX Electromagnetic Flowmeter
FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics
More informationMagnetic Flowmeter Systems
Series 8700 Magnetic Flowmeter Systems THE 8700 SERIES... Model 8712 C/U - Easiest to use local operator interface and works with any manufacturer s flowtubes Model 8712H/8707 High-Signal System - Pulsed
More informationSITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI
Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two
More informationVortexMaster FSV430, FSV450 Vortex flowmeter
Data Sheet DS/FSV430/450-EN Rev. D VortexMaster FSV430, FSV450 Vortex flowmeter Two-wire vortex flowmeter for measurement of the flow of gas, vapor and liquid Measurement made easy Intuitive operation
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More informationMobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA
Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for
More informationVortex Flow Measuring System prowirl 77
Technical Information TI 040D/06/en No. 50084974 Vortex Flow Measuring System prowirl 77 Reliable Flow Measurement of Gases, Steam and Liquids Safe Verified electromagnetic compatibility according to IEC
More informationDigital flow ELEMENT transmitter for continuous flow measurement
ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor
More informationKFS. Flap-type flow meter. Design and range of application
Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is
More informationOPTIMASS 1000 Technical Datasheet
OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
More informationMagnetostrictive Level Transmitter
Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Overview Söm-Tek TM The SKMT liquid level transmitter satisfies the demand for an analog communication interface for sightglass (bypass
More informationHTTF Transit Time Ultrasonic Flow Meter
Transit Time Ultrasonic Flow Meter Reduced material costs: clamp-on sensor eliminates the need for in-line flanges, pipe fittings, strainers, and filters Reduced installation time: the may be installed
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationRosemount 3101, 3102, and 3105
Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as
More informationwww. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER
www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring
More informationOPTIFLUX 1000 Technical Datasheet
OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when
More informationKMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display
KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical
More informationKENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents
KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter
More informationSignet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount Multi-Parameter input selection Large auto-sensing backlit display with at a glance visibility Dial-type
More informationVortexMaster FSV430, FSV450 Vortex flowmeter
Data Sheet DS/FSV430/450-EN Rev. F VortexMaster FSV430, FSV450 Vortex flowmeter Reliable measurement of liquids, gases and steam in volume, mass or energy units Measurement made easy ABB common look and
More informationSignet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount Multi-Parameter input selection Large auto-sensing backlit display with at a glance visibility Dial-type
More informationDesign and applications
Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated
More informationLevel Lance Model 5100
Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection
More informationRHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits
RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English
More informationUSER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS
Rev04009 USER MANUAL DEI MODEL USFT-CS USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER The Model USFT-CS is an ultrasonic transit time flow meter designed to accurately and reliably report the flow
More information600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet
Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration
More informationDVZ COMPACT VORTEX FLOWMETER
DVZ COMPACT VORTEX FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Measuring Ranges: 0.13-1.2 GPM to 2.7-26 GPM Accuracy: ±2.5 % of F.S. Vortex Shedding Technology with No Moving
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationUTM10 Series Ultrasonic Transit-time Flowmeters
Ultrasonic Transit-time meters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal liquid. The technology has inherent advantages
More information600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)
Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically
More informationCompact Orifice Flow Meter
Data Sheet DS/OM Issue 2 Compact Orifice Flow Meter OriMaster Integrated DP Flow measurement system combines primary element with DP Transmitter in a single flowmeter assembly One-piece flowmeter, pressure
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More informationAPT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A
Doc. No. : C3100-E05A Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement MODEL APT3100 Duon System Co.,Ltd. www.autrol.com Smart Pressure Transmitter APT3100 Standard Description
More informationValve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator
Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator ANSI version Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam
More informationDOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200
DOC. NO. : C3200-E04A FM APPROVED Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 APT3200 Smart Pressure Transmitter Standard SST Housing Description of Product The
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationCoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter
Data Sheet DS/FCB300/FCH300-EN Rev. H CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter 4-wire compact device For flow measurement of liquids and gases Measurement made easy CoriolisMaster
More informationI/A Series Intelligent Vortex Flowmeters Foxboro Model 84S Sanitary Flowmeters with HART Communication Protocol
Product Specifications I/A Series Intelligent Vortex Flowmeters Foxboro Model 84S Sanitary Flowmeters with HART Communication Protocol PSS 1-8A5 A The Foxboro Model 84S is part of a family of intelligent,
More informationRadar Level Measurement micropilot FMR 130 for stilling wells
Technical Information TI 258F/24/ae Radar Level Measurement micropilot FMR 130 for stilling wells Smart transmitter for non-contact measurement in metallic by-pass pipes and stilling wells Suitable for
More informationSwirlMaster FSS430, FSS450 Swirl flowmeter
Data Sheet DS/FSS430/450-EN Rev. B SwirlMaster FSS430, FSS450 Swirl flowmeter Two-wire swirl flowmeter for measurement of the flow of gas, vapor and liquid Measurement made easy Easy assembly Only the
More informationSITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview
Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:
More informationINTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:
Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:
More informationDial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator
Specifications General Input Channels One Input Types Digital (S 3 L) Serial ASCII, TTL level, 9600 bps Frequency Range 0.5 to 1500 Hz Accuracy 0.5% of reading Measurement Types Flow, ph/orp, Conductivity/Resis
More informationSeries Smart Pressure Transmitter
www.tek-trol.com TEK-BAR 3100 Series Smart Pressure Transmitter www.tek-trol.com 2 Introduction The Tek-Bar series of smart transmitters have excellent stability, high accuracy and include features that
More information1) What meter do I need in this application?
ELECTRONIC ELECTRONIC Choices 1) What meter do I need in this application? Meter choice is determined by: Level of accuracy required, flowrate, line size, viscosity, fitting type, pressure rating, temperature,
More informationKotron Model 82 CE RF Level Transmitter
Kotron Model 82 CE RF Level Transmitter DESCRIPTION The Kotron Model 82 RF Capacitance transmitter is one of the most cost effective level transmitters available today. Compact in size, it employs state-of-the-art
More informationSwirlMaster FSS430, FSS450 Swirl flowmeter
Data Sheet DS/FSS430/450-EN Rev. E SwirlMaster FSS430, FSS450 Swirl flowmeter Reliable measurement of liquids, gases and steam in volume, mass or energy units Measurement made easy Compact, space-saving
More informationWATERFLUX 3070 Technical Datasheet
WATERFLUX 3070 Technical Datasheet Engineered and manufactured for the water and wastewater industry Highly accurate measurement with extremely short in- and outlet lengths Battery operated, stand alone
More informationSignet Flow Transmitter
Signet 80- Flow *-80.090-* English -80.090- Rev. L 0/ English WARNING! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.
More informationSignet 9950 Dual Channel Transmitter
Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,
More informationOPTISONIC 7300 Technical Datasheet
OPTISONIC 7300 Technical Datasheet Ultrasonic gas flowmeter Wide application range No moving parts and no pressure loss Complete solution for gasflow measurement KROHNE CONTENTS OPTISONIC 7300 1 Product
More informationCost-Effective Coriolis Flow Meters. PRO Series Meters
Cost-Effective Coriolis Flow Meters CamCor TM PRO Series Meters GENERAL SPECIFICATION 50284153, Rev. 01 GENERAL Equipped with a sophisticated transmitter (including a selfdiagnostics feature, large display,
More informationDigital batch controller
INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 - The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement,
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationSarasota CM200 Sarasota HME900 Density Converter Electronics
Sarasota CM00 Sarasota HME00 Density Converter Electronics Users of Sarasota density meters or specific gravity analyzers are offered the choice of a HART compatible, field mounted density converter, or
More informationUSER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL DEI MODEL USFT-B
Rev012008 USER MANUAL DEI MODEL USFT-B USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER The Model USFT-B is an ultrasonic transit time flow meter designed to accurately and reliably report the flow
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature
More informationFLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual
SWITCH 600 Series Velocity Flow Sensor Instruction Manual Ultrasonic Velocity Sensor using Doppler Technology Model: FS-600 Manual Release Date: November, 2009 ECHO Process Instrumentation, Inc. CONTENTS
More informationFlow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,
DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration
More informationModel 8800C. Vortex Flowmeter with FOUNDATION Fieldbus FOUNDATION FIELDBUS CAPABILITY. Product Data Sheet
Product Data Sheet 00813-0100-4772 Model 8800C Vortex Flowmeter with FOUNDTION Fieldbus FOUNDTION FIELDBUS CPBILITY Interoperable with other FOUNDTION fieldbus instruments bility to control from anywhere
More informationSignet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Multiple sensor types supported with one instrument Dial-type digital bar graph Modules are field installable and replaceable
More informationFV4000, FS4000 Vortex Flowmeter / Swirl Flowmeter. 2-wire Compact Design Digital Signal Processor Converter Technology
Contents Data Sheet Rev. 10 FV4000, FS4000 Vortex Flowmeter / Swirl Flowmeter 2-wire Compact Design Digital Signal Processor Converter Technology For metering liquids, gases and steam FV4000 Vortex flowmeter
More information