MM1 Fan-coil Controller
|
|
- Wilfred Gray
- 6 years ago
- Views:
Transcription
1 MM1 Fan-coil controller MM1-A12 -- Stand alone MM1LA12 -- LO network MM1BA12 -- BAnet network MM1SA12 -- Local network Doc# A stand-alone or network connected unit controlling a three speed fan, a single step heater and a thermic valve. 2-pipe system with or without change-over On-off or PWM valve control Pre-set temperature set point or use with a MK2A22 wall control Inputs for Return air and water temperature sensors Input for Occupancy sensor Auxiliary input for various interlocks Power supply to unit: 230V A Direct switching of power to valve, fan and heater over plate for power terminals Plugable screw terminals 01
2 Index Refrences Design Dimensions Technical data Power terminals ommunication port Signal I/O terminals ontrol 05 Temperature control ontrol process Un-occupied mode onserve mode Selection Wiring examples Accessories Installation notes Mounting template LO earthing References MM1 range of controllers LO interface MM1 range of controllers BAnet interface LOWORKS Bus Wiring Guidelines LOWORKS etwork Wiring Aid Wall Unit (User interface) MM1LQ20 MM1BQ20 AT5-1LQ10 LOTKSQ10 MK2Q10 02
3 Design The MM1.. range of fan-coil controllers consist of a controller plus power supply housed in a fire retardant ABS enclosure. The power and low voltage terminals are situated on opposite sides of the enclosure. A cover plate is supplied for the power terminals. POWER TERMIAL OVER PLATE POWER TERMIALS HOUSIG PROGRAMMIG PORT ID BUTTO OMMUIATIO PORT SIGAL I/O TERMIALS ote: 230V supply to the unit is switched through the unit to the control valve, fan and heater element. Dimensions 92mm cover plate not shown 131mm TOP VIEW 41mm cover plate not shown
4 Technical Data Power terminals low med high 3 3 speed fan 230V A 3Amp max open T thermic actuator 230V A 100mA max LOW MED FA HIGH VALVE 230V ~ A ID B D HEAT 230V ~ L A B D heater element heat 230V A 1,5kW max. 230V A power supply in L LO DISP T T2 MM1LA12 IP-1 GD IP-2 GD 12v D ommunication port LO earth tag LO BAnet Local net 02 gnd signal A signal signal 04 B 04 signal 04 Signal I/O terminals MK2.. user interface (wall unit) signal signal 05 10K T temp.sensor Return air 10K T temp.sensor Water supply or discharge air Door / window switch Voltage free contact signal 1 gnd Occupancy sensor Power usage 720mW max Voltage free signal Oc signal 2 gnd 12V ote: 230V power to the unit must be wired to terminals and D only. External eutral or Live loops must not be installed. Terminals 09/10 can be configured for water temperature or for discharge air temperature. See selection code on page
5 Technical Data (continued) ote: All user interface units (wall unit on terminals 05/) have a built in temperature sensor. If however, a return air temperature sensor is wired to terminals / the return air sensor is dominant and the wall unit sensor is ignored. Wiring of the user interface to terminals 05/ is polarity insensitive. Voltage free contact inputs to terminals 11/12 and 13/14: Door/window switch (term.11/12) -- closed contact indicates door/window closed. Occupancy (term.13/14) -- closed contact indicates occupied. ontrol Temperature control cold water supply 100% heating element valve output -1,5-1,0-0,5 SP +0,5 +1,0 +1,5 100% valve hot water supply output -1,5-1,0-0,5 SP +0,5 +1,0 +1,5 ontrol Process Temperature set point entered on the wall unit can be from 18 up to 26. Switch over between heating and cooling is automatic with a 1 dead band between heating and cooling. Therefore a temperature rise of 0,5 above set point causes the controller to go into cooling mode and a fall to 0,5 below set point to go into heating mode. Indications on the wall unit: ooling mode -- Snow flake symbol Heating mode -- Sun symbol In between -- The letter A The controller use a 1 degree on/off band for both heating and cooling modes. 05
6 ontrol (continue) Valve control - on/off (solenoid or thermic): Opens fully on temperature reaching 1.5 from set point and closes fully should the temperature move to 0.5 from set point. Heater control - on/off: Switches on when temperature drops to 1.5 below set point and switches off should the temperature rise to 0.5 below set point. The fan speed control is either on/off or 3 speed. The three speed setting is entered on the wall unit. Two bars for low, four for medium and six for high speed. ontrol Process in un-occupied mode Input (voltage free) over terminals 13/14 is used for occupancy. A closed input places the controller in occupied mode and an open input in un occupied mode. Occupied mode: (closed contact) ormal control process as set out above. Un-occupied mode: (open contact) o heating or cooling is provided between 18 and 26. ooling "switches on" at 27,5 and off at 26. Heating "switches on" at 16.5 and off at 18. ontrol process in conserve mode Input (voltage free) over terminals 11/12 is used for energy waste monitoring. For instance a door and/or window switch. An open contact indicate an open window or door placing the unit into conserve mode. onserve mode: (open contact) Fan only. o heating or cooling will take place. ormal mode: (closed contact) ormal control process as set out above. Selection MM1aAb2 1 term.09/10 -- water temperature - L B S Alone standing LO connectivity BAnet connectivity Local network 2 term.09/10 -- discharge air temperature Only used in LO or BAnet aplications for report back on the building management system.
7 Wiring example MM1LA22 A typical wiring diagram for a fan-coil controller with LO, discharge air temperature monitoring, occupancy sensing and window monitoring. fan 3 valve T heater A B D low med high open on L (1) LO earth tag (6) LO (3) occupation sensor 12VD gnd signal Oc MK2.. wall unit (user interface) (2) window switch return air temperature (5) gnd signal discharge air temp. (4) otes on this example: 1) o eutral or Live looping on terminals. 2) Window open (open contact) -- controller in conserve mode. 3) Room unoccupied (open contact) -- controller in unoccupied mode. Bridge if not in use. 4) Discharge air temperature is measured for report back on the LO network. 5) If the return air temperature sensor is not installed room temperature is measured at the wall unit. 6) The earth tag must be wired, directly or indirectly, to 3rd pin Earth.
8 Accessories MK2A22 T10HB1 T10HB2 User interface (wall unit) 5 button. 10K T temperature sensor. 1m cable. 10K T temperature sensor. 2m cable. Installation notes Mounting template 92mm wiring area use M4 tap screw 120mm 190mm wiring area LO earthing On the MM1LA..0 configurations, the LO earth tag must be attached to the frame of the fan-coil unit. The fan coil frame must in turn be attached to the power supply 3rd pin earth.
9 Deman Manufacturing (Pty)Ltd 10 Steenbok street Koedoespoort 0186 Pretoria South Africa PO BOX 262 Gezina 01 Pretoria South Africa tel fax
STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application
STR-LCF Electronic Fan Coil Thermostat (Flush mounting) Datasheet Subject to technical alteration Issue date: 28.2.217 Application The fan coil room thermostat has been designed for individual control
More informationFCU-503 FAN COIL CONTROLLER WITH RDU-TOUCH INTERFACE
FCU-503 FAN COIL CONTROLLER WITH RDU-TOUCH INTERFACE BACnet Enabled Description The FCU-503 is designed to provide complete control of fan coil units and / or underfloor heating circuits. The FCU-5 incorporates
More informationApplication Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on triac output and electric reheater
Heating with LHW and cooling with CHW changeover Modulating control of heating and cooling valve (2 pipe) on triac Automatic or manual 3-speed fan control Room temperature and fan speed operation via KNX
More informationApplication Sheet Fan coil unit with variable fan, heating/cooling coil (2 pipe) on triac output and electric reheater
Heating with LHW and cooling with CHW changeover Modulating control of heating and cooling valve (2 pipe) on triac Automatic or manual variable fan speed control DC 0...10 V Room temperature and fan speed
More informationApplication Sheet Active chilled beam with variable fan, cooling coil and hot water radiator on triac output
Cooling with active chilled beam on triac output Optional heating with LHW Automatic or manual variable fan speed control DC 0...10 V Room temperature and fan speed operation via KNX PL-Link room operator
More informationRoom Temperature Controllers. for heating and cooling systems
3 048 RCU15 Room Temperature Controllers for heating and cooling systems RCU15 Choice of two-position or modulating PI control ON / OFF or PWM outputs for heating and cooling Control depending on room-
More informationRoom Temperature Controllers. for heating and cooling systems
3 048 RCU15 Room Temperature Controllers for heating and cooling systems RCU15 Choice of two-position or modulating PI control ON / OFF or PWM outputs for heating and cooling Control depending on room-
More informationTECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging
TECHNICAL DATASHEET #TDAX102000 35A DC MOTOR CONTROLLER P/N: AX102000 Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging with Electronic Assistant Features: Unidirectional or bi-directional
More informationDevice connection and commissioning can only be carried out by qualified professionals. Always make the connections while the power is switched off.
V1.2.0 (03.03.2014) 1 (21) This user guide is for controllers with the software version 1.2.0 or newer. WIRING Device connection and commissioning can only be carried out by qualified professionals. Always
More informationRoom Temperature Controllers. for heating and cooling systems
3 041 RCU10 RCU101 Room Temperature Controllers for heating and cooling systems RCU10 Choice of two-position or modulating PI control ON / OFF or PWM outputs for heating and cooling Operating modes: normal
More informationORDERING CODE Z-WAVE FREQUENCY COUNTRY/REGION
ZMNHDD1 868.4 MHz CEPT, China, Singapore, South Africa, UAE ZMNHDD2 921.4 MHz Australia, Brazil, New Zealand ZMNHDD3 908.4 MHz Chile, Mexico, USA/Canada ZMNHDD4 869.0 MHz Russia This module is used for
More informationApplication sheet for Green 300 series controllers. Title. Purpose. Application Controller Loop Configuration: Wiring: Explanation :
Furnace temperature control with Solid State Relay(SSR) AP35001 Control a furnace temperature by using UT350 temperature controller. Model UT350 can drive SSR as an actuator directly. Electrical Furnace
More informationInstruction. Actuator ICAD 600 / ICAD 900 / ICAD 1200 ICAD 600 ICAD 900 ICAD 1200 ICAD 600 ICAD 900. ICAD 1200 Fig. 2. Fig. 4
Instruction 027R9796 027R9796 Actuator ICAD 600 / ICAD 900 / ICAD 1200 ICAD 600 ICAD 900 ICAD 1200 ICAD 600 ICAD 900 ICAD 1200 Fig. 1 Fig. 2 Note: When mounting the ICAD make sure to push ICAD down to
More informationRoom Temperature Controllers. for heating and cooling systems
3 041 RCU10 RCU10.1 Room Temperature Controllers for heating and cooling systems RCU10... Choice of two-position or modulating PI control ON / OFF or PWM outputs for heating and cooling Operating modes:
More informationUniversal Controller
Universal Controller Overview and Configuration Manual Overview... 1 About this Manual... 1 Introduction... 5 Hardware Overview... 5 Software Overview... 7 Interpreting Flow Diagrams... 8 Foreign Language
More informationRoom Temperature Controllers. for heating and cooling systems
3 041 RCU10 RCU10.1 Room Temperature Controllers for heating and cooling systems RCU10... Choice of two-position or modulating PI control ON / OFF or PWM outputs for heating and cooling Operating modes:
More informationProduct Manual. SZ1025a. Description The SZ1025a is a microprocessor-based controller designed for VAV terminal unit applications.
Product Manual SZ0a VAV Box ontroller Description The SZ0a is a microprocessor-based controller designed for VAV terminal unit applications. Features Stand-alone or network operation Built-in velocity
More informationFCU-501 FAN COIL CONTROLLER WITH RDU-4 INTERFACE
FCU-501 FAN COIL CONTROLLER WITH RDU-4 INTERFACE BACnet Enabled Description The FCU-501 is designed to provide complete control of fan coil units and / or underfloor heating circuits. The FCU-5 incorporates
More informationActuator ICAD 600A / ICAD 600A-TS / ICAD 1200A
Installation Guide Actuator ICAD 600A / ICAD 600A-TS / ICAD 1200A 027R9966 ICAD 600A ICAD 600A-TS ICAD 1200A 027R9966 ICAD 600A / ICAD 600A-TS ICAD 1200A Fig. 1 Fig. 2 Note: When mounting the ICAD make
More informationELECTRONIC THERMOSTAT: T920
μnistδt ELECTRONIC THERMOSTAT: T One analog output DESCRIPTION The T series thermostats are microcomputer-based, proportional and integral (PI) devices with one analog 0 to 0 output. They can be used with
More informationNRT 105: Electronic fan-coil controller, equiflex
Product data sheet 4.04 R 105: Electronic fan-coil controller, equiflex How energy efficiency is improved ECO Meter for displaying the current energy consumption and digital input for the change-over between
More informationCommunicative heating controller
UC100 Communicative heating controller Summary UC100 is a communicative room heating controller with one PWM output for control of a radiator or electrical heater. It can work autonomously, or in connection
More informationSeries. integrated Control Motor LINEAR SOLUTIONS MADE EASY
integrated ontrol Motor ELETROMATE LINEAR SOLUTIONS MADE EASY A What is a? The SmartActuator is a controller, drive and motor integrated with an actuator for an all-in-one solution. Tolomatic has over
More informationELECTRONIC THERMOSTAT: T951
μnistδt ELECTRONIC THERMOSTAT: T9 One floating output One contact output DESCRIPTION The T9 series thermostats are microcomputer-based, proportional and integral (PI) devices with one floating (incremental)
More informationEPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20
89 220/101 ED EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES EPA-M1** single solenoid EPA-M2** double solenoid EPA-M3** 2 independent channels single solenoid valves RAIL MOUNTING TYPES: DIN
More informationP P S - M W S C A N 2 H
µ-controller-systems / HARD- & SOFTWARE-DESIGN POWER-SUPPLIES FROM MILLIWATTS TO KILOWATTS Device: PPS-MWS-2000-4000-CAN2H 04 / 2018 Page 1 / 6 S w i t c h i n g M o d e P o w e r S u p p l y f o r M a
More informationP/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939)
TECHNICAL DATASHEET #TDAX022000 Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference (SAE J1939) Features: 1 universal signal input 2 proportional or on/off outputs up to 3 A User
More informationSE8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller
SE8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller Version 10 2 HMI Display The User HMI is configurable and allows display functions such as Date, Time, Outdoor
More informationRoline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL
Roline L1 Series Humidity - Temperature Transmitters INSTRUCTION MANUAL 20030314 CONTENTS Overview... 3 Operation... 5 Power supply... 5 Operating range and limits... 5 Temperature compensation of the
More informationM1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL
M1 Series Humidity - Temperature Transmitter INSTRUCTION MANUAL 20031110 -2- CONTENTS Overview... 3 Operation... 4 Power supply... 4 Operating range and limits... 4 Temperature compensation of the humidity
More informationSRC-21x Series Climate Controllers with BACnet MS/TP
Product sheet CT2.153 Type SC-21x-BAC SC-21x Series Climate Controllers with BACnet MS/TP The SC-21x series controllers have been designed for climate control in room spaces. The controllers have up to
More informationSimplicity Communication Installation Instructions
ommunication Installation Instructions Tools equired Wire Strippers, and a small straight head screw driver. Materials equired 18 gage 3 conductor foil shielded wire with an extra drain wire, and Wire
More informationSC-225/SC-250/SC-325/SC-350 STATIC CONTACTOR
Safety Provisions Do not open the device enclosure. There are no user-servicable parts inside the device enclosure. Ensure that the earth connection of the device is done..!! Warning: Consider that there
More informationPRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature
PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature Temperature control: Feel good at any time of year Room thermostats Heating time switches Excellent products
More informationB350L, 3-Way, Diverting Ball Valve Chrome Plated Brass Ball and Nickel Plated Brass Stem
B350L, 3-Way, Diverting Ball Valve hrome Plated Brass Ball and Nickel Plated Brass Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating
More informationDigital Room Sensor Technical Guide
www.orioncontrols.com Digital Room Sensor Technical Guide TABLE OF CONTENTS OVERVIEW... 3 BASIC OPERATION... 4 Sensor Operation... 4 LED Operation... 4 MOUNTING AND WIRING... 5 Environmental Requirements...
More informationSeries R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting
FANs 216, 121 Technical Bulletin R48 Issue Date 0695 Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting Table of Contents Mounting... 1 Output Control... 2 Wiring...
More informationPEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES
PEAKTRONICS The Peaktronics AC Motor Interface is used to interface common electrical control signals to AC actuators. The unit provides the motor drive circuits, protection circuits, and isolation between
More information1 Digital input (24Vac or dry contact) Inputs
Fan oil Thermostat Fan oil Thermostat Features: Attractive modern look with large LD and backlight Icons driven information and 1 line of text information 2 Pipes Analog, ON/OFF or Floating 4 Pipes Analog,
More informationIntelligent Compact Controller
TCY-T0121 Intelligent Compact Controller Features Temperature control for 2-pipe, 4-pipe HVAC systems. Temperature range from 40 to 140 C. 1 independent PI and On/Off control loop to control temperature.
More informationMicroprocessor Based Multistage Temperature Controller & Two Channel 365 Day Time Switch. Made in Australia 100% Australian Owned Company
Microprocessor Based Multistage Temperature Controller & Two Channel 365 Day Time Switch HTC DIGITAL-TC Features Use Australian Made and designed Combined Temperature & Time Switch Functions Power Supply
More informationTitan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units
Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units 1 Time Scheduling RDU-4/TS - Description of Control Operation The temperature control and time scheduling for the building space is
More information17/2 Introduction. Display, Operation 17/6 Introduction 17/7 Pushbuttons 17/10 Pushbutton accessories 17/11 Remote controls
Siemens AG 2009 GAMMA wave Radio System /2 Introduction Display, Operation /6 Introduction /7 Pushbuttons /10 Pushbutton accessories /11 Remote controls Output Devices /12 Introduction /13 Binary output
More informationVT8300 Series Installation Guide 24 Vac Low Voltage
VT00 Series Installation Guide Low Voltage mercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation Terminal Identification & Function Terminal identification Wiring Typical Applications
More informationModbus VAV Controller Configuration Properties
Modbus VAV Controller Configuration Properties Modbus Object Type: Holding Registers Name Default Min Max Units Modbus Reg # Multiplier Focus Screen Modbus Notes DeviceType 0 0 0 None 1 1 Device (Not writable)
More informationE-BUS Digital Room Sensor Technical Guide
E-BUS Digital Room Sensor Technical Guide TABLE OF CONTENTS OVERVIEW... 3 BASIC OPERATION... 4 Sensor Operation... 4 LED Operation... 4 MOUNTING AND WIRING... 5 Dimensions... 5 Environmental Requirements...
More informationTECHNICAL DATASHEET #TDAX CAN SAE J1939, Dual Output Valve Controller
TECHNICAL DATASHEET #TDAX020200 CAN SAE J1939, Dual Output Valve Controller Features: Two independent, software controlled outputs selectable as: Proportional Current (up to 2.5A); Hotshot Digital; PWM
More informationCHC-400 Capacitive Torch Height Controller
CHC-400 Capacitive Torch Height Controller www.pure lo gic.ru Contacts: Moscow +7 (495) 505 63 74 Voronezh +7 (473) 204 51 56 149 Office 160, Leninsky avenue Voronezh, Russia, 394033 Monday - Thursday:
More informationTLC3-BCR-U Series Thermostat
OVERVIEW TLC3-BCR-U Series Thermostat Features Low power energy consumption: < 1W per unit Relays switching for outputs each up to 300W Temperature control for 2 or 4-pipe heating or cooling systems. Optional
More informationUSER MANUAL. Maxwell Technologies BOOSTCAP Ultracapacitor Energy Storage Modules for Low Duty Cycle Applications
USER MANUAL Maxwell Technologies BOOSTCAP Ultracapacitor Energy Storage Modules for Low Duty Cycle Applications Models: BMOD0125 P064 B02 BMOD0094 P075 B02 Document #1014204 Notice: The products described
More informationController. 1 Proportional amplifier module ESSK 103. ESSK 103 and ELSK Description. 1.2 Application examples. 1.
Controller ESSK 0 and ELSK 0 solid state electronics infinitely metering ergonomic design robust enclosure Proportional amplifier module ESSK 0. The ESSK 0 proportional amplifier is used to control the
More informationCurrent consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)
89 610/112 ED EWM-A-SV ANALOG AMPLIFIER CARD SERVOVALVE CONTROL RAIL MOUNTING TYPE: DIN EN 50022 OPERATING PRINCIPLE This card is designed for a dynamic control of servovalves with the current output controlled
More informationApplication Sheet Supply and extract VAV with analog VAV controller, heating and cooling coil and hot water radiator on triac output
Supply & extract air volume control with compact VAV controller on triac output Room temperature control Air quality control Heating with LTHW radiator on triac output Downdraft compensation Room temperature
More informationSealed Interface Control: EC20300
ISO 9001:2000 WITH DESIGN Certificate #02.002.1 Sealed Interface Control: EC20300 FEATURES: Weather tight control package Pulse Width Modulated output Waterproof altitude pressure and vapor release vent
More informationModel 12200A RCN PTAC/PTHP/FAN COIL CONTROL NODE OPERATION OUTPUTS G1 = FAN 1 G2 = FAN 2 G3 = FAN 3 O/B = Rev Valve W = HEAT Y = COMPRESSOR
Model 12200A RCN PTAC/PTHP/ COIL CONTROL NODE OPERATION OUTPUTS G1 = 1 G2 = 2 G3 = 3 O/B = Rev Valve W = HEAT Y = COMPRESSOR Operating Modes Summary (Refer to Logic Tables 1 5): 1. PTAC (Standard) Fan
More informationIAA100/IAA200 Analog Amplifiers Voltage/Current
Quick Start Guide IAA100/IAA200 Analog Amplifiers Voltage/Current Sensor Solutions Source Load Torque Pressure Multi-Axis Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For
More informationConfiguration Example of Temperature Control
Controllers Technical Information Configuration Example of Control controllers The following is an example of the configuration of temperature control. Controller Relay Voltage Current SSR Cycle controller
More information- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION
ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS
More informationExternal RF Driver. Electrical Driver for AOTF-crystal. Instruction Manual
External RF Driver Electrical Driver for AOTF-crystal Instruction Manual Table of Contents 1 General... 3 2 Compliance... 3 3 Labeling... 4 4 Interface... 5 4.1 Front Panel... 5 4.2 Back Panel... 6 4.2.1
More informationB 520 ELECTRONIC AMBIENT TEMPERATURE CONTROLLERS. RTB C2 Eng. COSTER BUS. B RTB C2 Eng MC REV 01
ELECTRONIC AMBIENT TEMPERATURE CONTROLLERS C BUS C2 Eng. B 520 - C2 Eng. 25.09.07 MC REV 01 B 520 25.09.07 MC REV 01 1 On-Off output or 1 modulating & 1 On-Off 2 modulating outputs with Pl control action
More informationTMC3 SERVO CARD For WEM/XEM Series Actuators Installation & Maintenance Manual
. GEERAL DESCRIPTIO The Triac TMC is a proportional AC Motor Controller, intended for use with split phase AC actuator motors. The actuator is controlled by comparing an external command signal to a feedback
More informationFuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.
89 251/217 ED EDM-M* DIGITAL AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES EDM-M1 single solenoid EDM-M2 double solenoid EDM-M3 two single solenoids independent channels RAIL MOUNTING TYPE: DIN EN 50022
More informationAC/DC Power Supply Series APPLICATION NOTE
-350 + -700 AC/DC Power Supply Series APPLICATION NOTE NV350_NV700 App notes 69498 12.doc Document Number 69498 Page 1 of 17 1. INPUT... 3 AC INPUT LINE REQUIREMENTS... 3 2. DC OUTPUT... 3 OUTPUT VOLTAGES...
More information2 Parts and diagrams. Order parts by authorized service providers. Related documentation and software. Fasteners used in this product
2 Parts and diagrams Order parts by authorized service providers Related documentation and software Fasteners used in this product How to use the parts lists and diagrams Assembly locations Covers Document
More informationMonitoring Based Commissioning using Visualization Techniques. Ben Burgoyne, CCP, LEED AP Session Number R1.47 3/6/2014 9:00 am Room 347
Monitoring Based Commissioning using Visualization Techniques Ben Burgoyne, CCP, LEED AP Session Number R1.47 3/6/214 9: am Room 347 1. Describe how Operating Costs can be REDUCED and Occupant Comfort
More informationStryker BACnet VAV Wizard Configuration Guide (WEBs-N4)
Environmental Combustion and Control Stryker BACnet VAV Wizard Configuration Guide (WEBs-N4) May 2016 31-00104-01 STRYKER VAV BACNETCONTROLLER Table of Contents INTRODUCTION... 7 Stryker BACnet VAV Controller...
More informationTechnical Information
Date of last update: Aug-14 Ref: REFRIGERATION - CONTROLLING DIGITAL SCROLL Application Engineering Europe 1 Introduction Refrigeration applications such as retail and convenience stores are requesting
More informationCONNOLS-AIR. AIR TERMINAL UNITS Engineered for Versatile Application and Energy Conservation
CONNOLS-AIR AIR TERMINAL UNITS Engineered for Versatile Application and Energy Conservation Marina Bay Business District is considered the trendiest and most technologically advance area for business in
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationRadio Control Installation and Operating Instructions System 4
Radio Control Installation and Operating Instructions System 4 P.O. Box 403, One Cedar Parkway, Jackson, WI 53037 Phone: 800-628-1909 Fax: 262-677-2058 Revision: April 19, 2012 Contents Introduction 3
More informationB2 Series Characterized Control Valve, Spring Return Actuator
Series Characterized Control Valve, Spring ctuator Two-way Valve with Stainless Steel all and Stem, NPT Female Ends Service: Flow Characteristic: Media Temp Range: Maximum Differential: Pressure ( P) mbient
More informationExcel 10 W7761A Remote Input/Output Device
Excel 0 W776A Remote Input/Output Device INSTALLATION INSTRUCTIONS PRODUCT DESCRIPTION The W776A Remote Input/Output (RIO) Device is a Free Topology Transceiver (FTT) LonMark compliant device in the Excel
More informationTECHNICAL DATASHEET #TDAX021901
TECHNICAL DATASHEET #TDAX021901 8 In, 5 Output Valve Controller 6 Universal Analog Inputs, 1 Digital Input 1 Magnetic Pickup Sensor Input 4-2.5A Proportional or On/Off Outputs 1-2.5A Digital Output CANopen
More informationUBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5
Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Energy & Water Services.2 UBC Building Operations 1.2 Description.1 UBC requirements for Substation Transformers. 2.0 MATERIAL AND DESIGN REQUIREMENTS
More informationUSER MANUAL XLB-650 Short Arc Xenon Lamp Ballast
26 Ward Hill Dr., Bradford, MA 01835 Phone: +1-978-241-8260 Fax: +1-978-241-8262 USER MANUAL XLB-650 Short Arc Xenon Lamp Ballast The XLB-650 Xenon lamp ballast is a very compact power supply designed
More informationMC450/MC650 (MC750) OPERATING INSTRUCTIONS
MC450/MC650 (MC750) OPERATING INSTRUCTIONS MC 2 AUDIO Ltd., Units 6 & 7 Kingsgate, Heathpark Industrial Estate, HONITON, Devon EX14 1YG England Tel: ++(0)1404.44633 Fax: ++(0)1404.44660 www.mc2-audio.co.uk
More informationInstruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information
Instruction INFOCAL 8 Energy calculator 1.0 Table of contents 1.0 Table of contents...1 2.0 Safety notes and product information...1 3.0 Installation of energy calculator...2 4.0 Installation of temperature
More informationEIB/KNX Switch Actuators. User manual
EIB/KNX Switch Actuators User manual IT KNT 004 IT KNT 012 Tel.: +34943627988 E-mail: knx@dinuy.com Web: www.dinuy.com Contents 1. Introduction --------------------------------------------------------------------------------------------------------------
More informationC0330, C0530, C0630, C0830, C1030 Service Parts
This part list contains the service parts for the air cooled, water cooled and remote air cooled C00, C00, C00, C00, C00 ice machines. There was a change to panels and the C00 air cooled condenser in late
More informationThink About Control Fundamentals Training. Terminology Control. Eko Harsono Control Fundamental - Con't
Think About Control Fundamentals Training Terminology Control Eko Harsono eko.harsononus@gmail.com; 1 Contents Topics: Slide No: Advance Control Loop 3-10 Control Algorithm 11-25 Control System 26-32 Exercise
More informationUser Instructions For TopTronic RS-10
User Instructions For TopTronic RS-0 409ENG-Dec0 Hoval Ltd Northgate Newark Nottinghamshire NG4 JN Phone 066 677 Fax 066 675 Index 409ENG-Dec0 Introduction Introduction... Controls... Display... User instructions
More informationHB-25 Motor Controller (#29144)
Web Site: www.parallax.com Forums: forums.parallax.com Sales: sales@parallax.com Technical: support@parallax.com Office: (916) 624-8333 Fax: (916) 624-8003 Sales: (888) 512-1024 Tech Support: (888) 997-8267
More informationEnergy Conservational. External Contact Interface Module. Example
System Controller Energy Conservational Guest Room Management system saves you energy and money on cooling an unoccupied room: the air-conditioner is activated when Key-Tag is in place and turns off when
More informationR7426A. MicroniK 200 TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK
MicroniK 200 R7426A TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK PRODUCT DATA Fig. 1. Temperature controller FEATURES Microcontroller design based on modern digital technology User interface
More information- SMART TUNE - PID CONTROL - UNIVERSAL, 3 WIRE - TC, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER
MULTI - FUNTION ONTROLLERS - SMART TUNE - PID ONTROL - UNIVERSAL, 3 WIRE - T, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER WITH POTENTIOMETER FEEDBAK -
More informationRT-5005/5006/5007/5008
Replaces: 09.12 Electro-hydraulic Control Digital Proportional Amplifier Type: RT-5005/5006/5007/5008 Series: 3X Table of contents Contents Page Features 1 Ordering code 2 Functional description 2 Block
More information2, 4, & 6 Button Application Tool
2, 4, & 6 Button Application Tool M009.0.0-246_But_App Customer Name: Contact Name: Email: Phone: Application Description / Machine Type: Date of Submission: / / Revision: 2014 Cervis, Inc. 2, 4, & 6 Button
More information43.019/1. NRT 300: Electronic controller for air-conditioning (heating/cooling) Sauter Components
43.09/ NR 300: Electronic controller for air-conditioning (heating/cooling) For fixed-value control (I control, continuous) in air-conditioning systems, for residential and business premises. Used with
More informationNEW TOUGHEST WIND SENSORS THE WORLD S 1:2
F T 74 2 D ATA S H E E T NEW S U R FA C E M O U N T D E S I G N E D F O R I N T E G R AT I O N THE WORLD S TOUGHEST WIND SENSORS WWW.FTTECHNOLOGIES.COM 1:2 PROVEN IT LOOKS DIFFERENT BECAUSE IT IS DIFFERENT
More informationT150C / T151C Configurator
T150C / T151C Configurator Customer Name: Machine Name\Model Number: Revision Number: Please note revision history details on last page for updates to existing configurators. Date: Contact Name: Contact
More informationH7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors
H765A, H765A, H766A, H766A Series 000 Humidity/Temperature Sensors WALL-MOUNT MODELS INSTALLATI INSTRUCTIS APPLICATI The H765A, H766A, H765A and H766A Wall-Mount Humidity/Temperature Sensors are universal
More informationtheben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77
Fan Coil Actuator FCA 1 FCA 1 492 0 200 Version: Jan-08 (Subject to change) Page 1 of 77 Contents 1 Functional characteristics...4 1.1 Operation and display...5 1.2 Advantages of the FCA 1...5 1.2.1 Special
More informationMulti-Channel High Performance Data Acquisition System and Digital Servo Controller Module
VDSP-31 VXI MODULE Multi-Channel High Performance Data Acquisition System and Digital Servo Controller Module OVERVIEW The VDSP31 is a VXI based, multi-channel data acquisition system and digital servo
More informationCapacitive Torch Height Controller. CHC-200E Instruction
HYD CNC Technology CO.,LTD Tel:+86 755 26625800 Fax:+86 755 26729960 www.hydcnc.com Capacitive Torch Height Controller CHC-200E Instruction (Revision 2011) SAFETY: Please read this manual fully before
More informationUse of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.
Use of the application program Product family: Product type: Manufacturer: Heating, air conditioning, ventilation Thermostat Siemens Name: Temperature controller UP 237 DELTA i-system Order no.: 5WG1 237-2AB_1
More informationControl solutions Biofloor
MR24 Central radio controller 24V Connect COMAP offers the Connect control system as part of its underfloor heating and cooling solution. Composed of a central radio control module (MR24), wireless digital
More informationVT8600 Series User Interface Guide Rooftop Unit, Heatpump and Indoor Air Quality Controller
1 VT8600 Series User Interface Guide Rooftop Unit, Heatpump and Indoor Air Quality Controller Version 11 2 Table of Contents Section 1 Introduction 4 User and Integrator Screens 4 Disclaimer 5 HMI Display
More informationContinental Hydraulics Installation Manual CEM-RA-A
CEM-RA-A Description: This ramp amplifier drives either single or dual solenoid proportional valve coils up to 2.6A. It is suitable to control current to either proportional directional, flow, or pressure
More information4CONTROL VALVES CONTROL VALVES ULTRAFLO BUTTERFLY VALVES 522 SERIES NEW! H2X E2X KMSC-0 SPECIFICATIONS
SERIES DESRIPTION The Series resilient seated butterfly valves are available in "-0" sizes. Economical and designed to meet todayʼs HV and industrial process requirements, they come standard with full
More informationApril 1994 UCM-420A. Setpoint Controller. Operating and Installation Instructions
April TM UCM-A Setpoint Controller Operating and Installation Instructions A LARGE number of applications in a SMALL package... REMOTE SETPOINT CONTROLLER LOCAL SETPOINT CONTROLLER - ma SIGNAL GENERATOR
More information