Lights. Grote Zaal. DESK 1x High End Roadhog 4 (software v LIGHTPLOT Separated. 1x Hog3 playback wing. PATCHLIST See page 2
|
|
- MargaretMargaret Stewart
- 5 years ago
- Views:
Transcription
1 Grote Zaal Lights DESK 1x High End Roadhog 4 (software v (b2117) 1x Hog3 playback wing Nb.: All lights are controlled by Art-Net, see patchlist for details! LIGHTPLOT Separated PATCHLIST See page 2 DIMMERS 120x Beo dimmerchannel 3,6kW on CEE32 1p in grid 24x dimmerchannel 2,3kw in mobile rack on stagefloor STAGE - CONVENTIONAL 3x Par64 ACL-set 2kW 4x 4-lite 2,3 kw 10x Par64 Floorcan 1kW medium STAGE - INTELLIGENT 12x Martin Mac Viper Profile 22x Martin Mac Aura XB 12x CLS rgbaw-uv LED 4x Martin Atomic strobe STAGE - DATA 4x Cat6A stage (2x S.L., 2x S.R.) 4x Cat6A (2xFOH, 2xRegie) 6x Dmx in (4xFOH, 2xRegie) 8x Dmx out (4x S.L., 4x S.R.) FRONTLIGHT 12x Robert Juliat 15-40deg 2kW (fixed in catwalk) 32x Etc Source four 15-30deg 750W (fixed in catwalk) 2x Followspot Robert Juliat Super Korrigan 1,2kW HMI SMOKE 1x Mdg APS 1x Honeywell Pro HHV180E fan Update: Page 1
2 Grote Zaal Lights Patchlist D M X - P AT C H C o n ve n t i o n e e l G u e s t d e s k ( A r t N e t 1.1) H o u s e d e s k ( A r t n e t 0. 1 ) 301 Portable Dimmer Stage Left 301 t/m Robert Juliat 15-40deg 2kW Grid 1 2 Robert Juliat 15-40deg 2kW Grid 2 3 Robert Juliat 15-40deg 2kW Grid 3 4 Robert Juliat 15-40deg 2kW Grid 4 5 Robert Juliat 15-40deg 2kW Grid 5 6 Robert Juliat 15-40deg 2kW Grid 6 7 Robert Juliat 15-40deg 2kW Grid 7 8 Robert Juliat 15-40deg 2kW Grid 8 9 Robert Juliat 15-40deg 2kW Grid 9 10 Robert Juliat 15-40deg 2kW Grid Robert Juliat 15-40deg 2kW Grid Robert Juliat 15-40deg 2kW Grid Etc Source four 15-30deg 750W Grid 13 2 ETC on 1CH 14 Etc Source four 15-30deg 750W Grid 14 2 ETC on 1CH 15 Etc Source four 15-30deg 750W Grid 15 2 ETC on 1CH 16 Etc Source four 15-30deg 750W Grid 16 2 ETC on 1CH 17 Etc Source four 15-30deg 750W Grid 17 2 ETC on 1CH 18 Etc Source four 15-30deg 750W Grid 18 2 ETC on 1CH 19 Etc Source four 15-30deg 750W Grid 19 2 ETC on 1CH 20 Etc Source four 15-30deg 750W Grid 20 2 ETC on 1CH 21 Etc Source four 15-30deg 750W Grid 21 2 ETC on 1CH 22 Etc Source four 15-30deg 750W Grid Etc Source four 15-30deg 750W Grid Etc Source four 15-30deg 750W Grid Etc Source four 15-30deg 750W Grid Etc Source four 15-30deg 750W Grid Etc Source four 15-30deg 750W Grid Etc Source four 15-30deg 750W Grid Etc Source four 15-30deg 750W Grid Etc Source four 15-30deg 750W Grid Etc Source four 15-30deg 750W Grid Etc Source four 15-30deg 750W Grid Etc Source four 15-30deg 750W Grid Etc Source four 15-30deg 750W Grid Etc Source four 15-30deg 750W Grid Etc Source four 15-30deg 750W Grid Etc Source four 15-30deg 750W Grid Etc Source four 15-30deg 750W Grid 38 Gobo SUTU 39 Etc Source four 15-30deg 750W Grid 39 Gobo SUTU 40 Etc Source four 15-30deg 750W Grid 40 Gobo Radio 4 41 Etc Source four 15-30deg 750W Grid 41 Gobo AVROTROS 201 ETC S4 PAR Narrow Grid 201 Orchestra Light 202 ETC S4 PAR Narrow Grid 202 Orchestra Light 203 ETC S4 PAR Narrow Grid 203 Orchestra Light 204 ETC S4 PAR Narrow Grid 204 Orchestra Light 205 ETC S4 PAR Narrow Grid 205 Orchestra Light 206 ETC S4 PAR Narrow Grid 206 Orchestra Light 207 ETC S4 PAR Narrow Grid 207 Orchestra Light 208 ETC S4 PAR Narrow Grid 208 Orchestra Light 209 ETC S4 PAR Narrow Grid 209 Orchestra Light 210 ETC S4 PAR Narrow Grid 210 Orchestra Light 211 ETC S4 PAR Narrow Grid 211 Orchestra Light Update: Page 2
3 212 ETC S4 PAR Narrow Grid 212 Orchestra Light 213 ETC S4 PAR Narrow Sixbar 213 Orchestra Light 214 ETC S4 PAR Narrow Sixbar 214 Orchestra Light 215 ETC S4 PAR Narrow Sixbar 215 Orchestra Light 216 ETC S4 PAR Narrow Sixbar 216 Orchestra Light 217 ETC S4 PAR Narrow Sixbar 217 Orchestra Light 218 ETC S4 PAR Narrow Sixbar 218 Orchestra Light 219 ETC S4 PAR Narrow Sixbar 219 Orchestra Light 220 ETC S4 PAR Narrow Sixbar 220 Orchestra Light 221 ETC S4 PAR Narrow Sixbar 221 Orchestra Light 222 ETC S4 PAR Narrow Grid 222 Orchestra Light 223 ETC S4 PAR Narrow Grid 223 Orchestra Light 224 ETC S4 PAR Narrow Grid 224 Orchestra Light 225 ETC S4 PAR Narrow Grid 225 Orchestra Light 226 ETC S4 PAR Narrow Grid 226 Orchestra Light 227 ETC S4 PAR Narrow Grid 227 Orchestra Light 228 ETC S4 PAR Narrow Grid 228 Orchestra Light 229 ETC S4 PAR Narrow Grid 229 Orchestra Light 230 ETC S4 PAR Narrow Grid 230 Orchestra Light 231 ETC S4 PAR Narrow Grid 231 Orchestra Light 232 ETC S4 PAR Narrow Grid 232 Orchestra Light 233 ETC S4 PAR Narrow Grid 233 Orchestra Light 234 ETC S4 PAR Narrow Grid 234 Orchestra Light 235 ETC S4 PAR Narrow Grid 235 Orchestra Light 236 ETC S4 PAR Narrow Grid 236 Orchestra Light 237 ETC S4 PAR Narrow Grid 237 Orchestra Light 238 ETC S4 PAR Narrow Grid 238 Orchestra Light 239 ETC S4 PAR Narrow Grid 239 Orchestra Light 240 ETC S4 PAR Narrow Grid 240 Orchestra Light 241 ETC S4 PAR Narrow Grid 241 Orchestra Light 242 ETC S4 PAR Narrow Grid 242 Orchestra Light 243 ETC S4 PAR Narrow Grid 243 Orchestra Light 244 ETC S4 PAR Narrow Grid 244 Orchestra Light 245 ETC S4 PAR Narrow Grid 245 Orchestra Light 246 ETC S4 PAR Narrow Grid 246 Orchestra Light 247 ETC S4 PAR Narrow Grid 247 Orchestra Light 248 ETC S4 PAR Narrow KlankKaatser 248 Orchestra Light 249 ETC S4 PAR Narrow KlankKaatser 249 Orchestra Light 101 FREE CHANNEL LX FREE CHANNEL LX FREE CHANNEL LX FREE CHANNEL LX FREE CHANNEL LX FREE CHANNEL LX Four Light Blinder LX Four Light Blinder LX Four Light Blinder LX Four Light Blinder LX ACL Set LX FREE CHANNEL LX ACL Set LX FREE CHANNEL LX FREE CHANNEL LX FREE CHANNEL LX FREE CHANNEL LX FREE CHANNEL LX ACL Set LX FREE CHANNEL LX FREE CHANNEL LX FREE CHANNEL LX FREE CHANNEL LX FREE CHANNEL LX Led houselights Roof 401 t/m Pilars Hall Fluorescence entry s Hall Fluorescence ceiling Roof Uplighters ceiling Roof 512 Update: Page 3
4 I n t e l l i g e n t G u e s t d e s k ( A r t N e t 1.2) H o u s e d e s k ( A r t n e t 0. 2 ) # D e s c r i p t i o n W h e r e A d d r e s s FX R e m a r k s 1 Martin Mac Viper LX 4 1 Basic 2 Martin Mac Viper LX 4 27 Basic 3 Martin Mac Viper LX 4 53 Basic 4 Martin Mac Viper LX 4 79 Basic 5 Martin Mac Viper LX Basic 6 Martin Mac Viper LX Basic 7 Martin Mac Viper LX Basic 8 Martin Mac Viper LX Basic 9 Martin Mac Viper StageFloor 209 Basic 10 Martin Mac Viper StageFloor 235 Basic 11 Martin Mac Viper StageFloor 261 Basic 12 Martin Mac Viper StageFloor 287 Basic 1 Martin Atomic strobe LX channel mode 2 Martin Atomic strobe LX channel mode 3 Martin Atomic strobe LX channel mode 4 Martin Atomic strobe LX channel mode 17 Mac Aura XB StageFloor 329 Extended Mode 18 Mac Aura XB StageFloor 354 Extended Mode 19 Mac Aura XB StageFloor 379 Extended Mode 20 Mac Aura XB StageFloor 404 Extended Mode 21 Mac Aura XB StageFloor 429 Extended Mode 22 Mac Aura XB StageFloor 454 Extended Mode I n t e l l i g e n t G u e s t d e s k ( A r t N e t 1.3) H o u s e d e s k ( A r t n e t 0. 3 ) # D e s c r i p t i o n W h e r e A d d r e s s FX R e m a r k s 1 Mac Aura XB LX 1 1 Extended Mode 2 Mac Aura XB LX 1 26 Extended Mode 3 Mac Aura XB LX 1 51 Extended Mode 4 Mac Aura XB LX 1 76 Extended Mode 5 Mac Aura XB LX Extended Mode 6 Mac Aura XB LX Extended Mode 7 Mac Aura XB LX Extended Mode 8 Mac Aura XB LX Extended Mode 9 Mac Aura XB LX Extended Mode 10 Mac Aura XB LX Extended Mode 11 Mac Aura XB LX Extended Mode 12 Mac Aura XB LX Extended Mode 13 Mac Aura XB LX Extended Mode 14 Mac Aura XB LX Extended Mode 15 Mac Aura XB LX Extended Mode 16 Mac Aura XB LX Extended Mode 1 CLS Pixelbar Tricolore StageFloor 401 Synchronize mode, 3 channel RGB for complete bar 2 CLS Pixelbar Tricolore StageFloor 404 Synchronize mode, 3 channel RGB for complete bar 3 CLS Pixelbar Tricolore StageFloor 407 Synchronize mode, 3 channel RGB for complete bar 4 CLS Pixelbar Tricolore StageFloor 410 Synchronize mode, 3 channel RGB for complete bar 5 CLS Pixelbar Tricolore StageFloor 413 Synchronize mode, 3 channel RGB for complete bar 6 CLS Pixelbar Tricolore StageFloor 416 Synchronize mode, 3 channel RGB for complete bar 7 CLS Pixelbar Tricolore StageFloor 419 Synchronize mode, 3 channel RGB for complete bar 8 CLS Pixelbar Tricolore StageFloor 422 Synchronize mode, 3 channel RGB for complete bar 9 CLS Pixelbar Tricolore StageFloor 425 Synchronize mode, 3 channel RGB for complete bar 10 CLS Pixelbar Tricolore StageFloor 428 Synchronize mode, 3 channel RGB for complete bar 11 CLS Pixelbar Tricolore StageFloor 431 Synchronize mode, 3 channel RGB for complete bar 12 CLS Pixelbar Tricolore StageFloor 434 Synchronize mode, 3 channel RGB for complete bar Update: Page 4
5 G u e s t d e s k ( A r t N e t 1.4) H o u s e d e s k ( A r t n e t 0. 4 ) S t a g e r i g h t f l o o r P o r t 4 N o d e G u e s t d e s k ( A r t N e t 1.5) H o u s e d e s k ( A r t n e t 0. 5 ) S t a g e r i g h t f l o o r P o r t 5 N o d e G u e s t d e s k ( A r t N e t 1.6) H o u s e d e s k ( A r t n e t 0. 6 ) D i m m e r r oom P o r t 5 N o d e IP-ADRESSES LIGHTNETWORK Location Housedesk Guestdesk Cuecore Nodes Remotes Grote zaal Ronda Pandora Hertz Cloud Workshop Plein 5& Foyers Roof Rabo open stage Input node Output node House laptop Update: Page 5
Clay Paky Alpha Beam 300 Clay Paky Alpha Spot HPE 300
INTELLIGENT MOVING LIGHT Martin Mac Quantum Wash Martin Mac Viper AirFx Martin Mac III Profile TM Martin Mac 2000 Profile TM Martin Mac 2000 Wash TM Martin Mac 700 Profile TM Martin Mac 700 Wash TM 32
More informationLighting Specifications
Lighting Specifications January 2017 Royal Albert Hall Kensington Gore London SW7 2AP 020 7589 3203 www.royalalberthall.com Royal Albert Hall Lighting Specifications About This Document These Lighting
More informationGreen Room: Fridge, microwaves and tea and coffee making facilities (tea and coffee available subject to small donation)
Salberg - Technical Information Visiting Company Specification Updated February 2018 STAGE Stage Information: Width: 8300 Max Upstage, 5000 Max between seating blocks Depth: 7000 Max, 3500 Max between
More informationTECHNICAL RIDER OCTOBER 2015
TECHNICAL RIDER OCTOBER 2015 1004 St-Catherine Est, Montréal, Québec, H2L 2G2, Canada Tel.: 514-845-3524 TABLE OF CONTENTS Address Parking and loading dock Stage Stage curtains Dressing rooms Truss and
More informationWe might bring a single IE system. Shure PSM900 - L6. We will let you know in advance.!
Mandrake s Monster travels with: Joost Muller FOH/Tourmanager George Grein Backliner Zis Ankoné Light operator FOH: A minimum of 32 mono channels, 4 stereo channel and 8 sub groups is required, this includes
More informationAlways check availability of equipment Additional charges may apply PLEASE NOTE Stock availability may differ due to repairs etc
Technical Specifications SEATING CAPACITY Auditorium with no sound position: 366 Auditorium with sound position: 351 Auditorium with pit covered: 323 Sound position equates to 15 seats Four seats are reserved
More informationTECHNICAL RIDER SALA BARTS BARCELONA ARTS ON STAGE. BARTS is a venue located at Barcelona city centre where most important theatres are.
TECHNICAL RIDER SALA BARTS BARCELONA ARTS ON STAGE BARTS is a venue located at Barcelona city centre where most important theatres are. BARTS Avda. Paral.lel, 62 08001 BARCELONA http://www.barts.cat STAGE
More informationUsed Gear For Sale. Price includes case. quantities only. Price includes 2 way. case. Sold in case. quantities only. Price includes 4 way
(402) 592-5522 Category Image r Model Details/Cases Qty. Available Condition Dimensions grandma2 Full MA Lighting s most powerful console and offers includes case the control of conventional light, moving
More informationGECC Theatre Technical Specifications
GECC Theatre Technical Specifications Senior Technician: Jayden Allen Mobile: 0417 097 992 Landline: 07 4972 2822 Email: JaydenA@gladstone.qld.gov.au Venue: Phone: 07 4972 2822 Website: www.gladecc.com.au
More informationPower/Watts/Features 1.MOVING LIGHTS. Profile Range Chauvet Rogue R2 Spot 240w LED, 16.5 Martin Mac 250 Entour MSD 250, 14.
1.MOVING LIGHTS Profile Range Chauvet Rogue R2 Spot 240w LED, 16.5 Martin Mac 250 Entour MSD 250, 14 Martin Mac 700 Profile 700HTI, 16-30 Zoom Philips Showline SL LEDSPOT 300 270W LED, 10-45 Zoom, Framing
More information(English) Stage. Stage area is 12 meters wide and 9 meters deep.
Stage (English) Stage area is 12 meters wide and 9 meters deep. Full depht of stage: 11,4m Height from stage floor to ceiling: 12,9m Stage side area: W= 8,6m x D= 4,7m (Stage Right) Proscenie height: 6m
More informationFOLKEN STORSALEN - FOH Production Specs - General Information
FOLKEN STORSALEN - FOH Production Specs - General Information Venue Promoter Visiting address Postal address Vat ID Folken Storsalen Studentersamfunnet Folken Løkkeveien 24 4008 Stavanger Norway Postboks
More informationOveruren. Picture by Event Photographers United
Product guide Overuren. Picture by Event Photographers United In response to the rapid evolution in the audiovisual industry and the demands of our professional customers, we proudly present: LUXIBEL.
More informationHIRE PRICE LIST PROFESSIONAL STAGING, LIGHTING, SOUND & EFFECTS
HIRE PRICE LIST PROFESSIONAL STAGING, LIGHTING, SOUND & EFFECTS Additional LIGHTING Profile Spots - Project a hard edged beam with shutters for beam shaping. 12v 50w Accent Profile $10.00 $4.00 500w Zoom
More informationTest product RUSH Scanner 1 LED. RUSH MH11 Beam. RUSH MH10 Beam FX. RUSH MH 8 Mini Profile. RUSH MH 7 Hybrid. kr Add to basket teaser test
Test product 2017 teaser test RUSH Scanner 1 LED The RUSH Scanner 1 LED is designed to enable lighting designers to boost the wow factor and energize crowds with high-speed mid-air looks in a variety of
More informationLighting Effects LED video Control Atmospheric effects
OCTOBER 2013 MARTIN NEWS The award-winning MAC Viper Family and the new RUSH range of affordable effect lights highlight the latest in Martin product innovation with new solutions also available across
More informationJockey Club Auditorium - Technical Information
Jockey Club Auditorium - Technical Information General Set-up Jockey Club Auditorium operates on a bare-walls touring policy. That is, all equipment is normally setup and struck within the booking period.
More informationThe Bridgewater Hall Technical Specifications
The Bridgewater Hall Technical Specifications General Information Capacity (Maximum) Fixed seating auditorium: 2341 on four levels, including 16 wheelchair spaces Artist s Rooms/Orchestra Rooms/Production
More informationMAC Viper Performance. MAC Viper Quadray
NOVEMBER 2013 MAC Viper Performance MARTIN NEWS The award-winning MAC Viper Family and the new RUSH range of affordable effect lights highlight the latest in Martin product innovation with new solutions
More informationclearlight Hire Equipment List NEW
c Please contact one of our friendly staff to obtain an obligation free, itemised hire quotation. We offer daily, weekly and longer term hire periods and can include freight, consumables (colour filters,
More informationLismore City Hall Churchill Auditorium Technical Specifications
Auditorium Technical Specifications 2014/2015 Please complete and return to venue@norpa.org.au / phone: 02 6622 0300 / fax: 02 6622 3175 Lismore City Hall is managed by Northern Rivers Performing Arts
More informationJeanne and Peter Lougheed Performing Arts Centre
Theatre Technical Specifications Seating Capacity: 584 Seats Maximum 573 with basic holds (7 seats removed for sound console, 4 FOH Holds) (Space for sound console at the back of the orchestra level is
More informationHIRE EQUIPMENT PRICE GUIDE
HIRE EQUIPMENT PRICE GUIDE Amplifiers QSC PLX2402 QSC PLX 1602 QSC PLX 3002 QSC PL236 $66.00 Audio Consoles A&H ZED6FX A&H ZED10FX A&H ZED14FX A&H Wizard 16/2 A&H GL2400/24 A&H ML4000/48 A&H dlive S7000
More informationTHE REPUBLIC CULTURAL CENTRE TECHNICAL FACILITIES (THEATRE)
THEATRE THEATRE SEATING CAPACITY: 1,111 (maximum) Stalls (Level 1) 744 wagon seats 62 orchestra pit seats 32 Balcony (Level 2) 273 Total: 1,111 22 seats in Stalls are removable for a maximum of 10 x wheelchair
More informationSurplus Liquidation of Forklifts, Staging, Lighting Equipment, Tools and Business Supplies
Surplus Liquidation of Forklifts, Staging, Lighting Equipment, Tools and Business Supplies Auction Opens: Tue, Oct 24 10:00am Auction Closes: Thu, Oct 26 10:00am 0100 Hyster S30XL Propane Forklift 0101
More informationTECHNICAL SPECIFICATIONS LABAN THEATRE
TECHNICAL SPECIFICATIONS LABAN THEATRE The Bonnie Bird theatre is intended to provide a first class environment for an audience of 296 to watch contemporary dance performed by both student and visiting
More informationFRONT HOUSE AND BACKSTAGE
Technical Rider FRONT HOUSE AND BACKSTAGE - The Cinema-Theatre is equipped for cinema, theatre, music, dance and conferences. - It has a seating capacity of 219, 3 being suitable for wheelchairs. - Lift
More informationTECHNICAL PACK 1 SPACING DIAGRAM 2 TECHNICAL DIAGRAM 3 DEFAULT LIGHTING SET-UP 4 LIGHTING UNITS 5 DEFAULT PATCHING CONTACT:
TRIP SPACE TECHNICAL PACK SPACING DIAGRAM 2 TECHNICAL DIAGRAM 3 DEFAULT LIGHTING SETUP 4 LIGHTING UNITS 5 DEFAULT PATCHING CONTACT: TECHNICAL: MICHAEL PICKNETT MIKE@TRIPSPACE.CO.UK PRODUCTION: GIULIANA
More informationThe Crossing Venue Information & Specification 2013
THE CROSSING VENUE INFO & SPECIFICATION 1 The Crossing Venue Information & Specification 2013 Phone: 0121 694 5000 8am - 8pm Mon-Thurs 8am - 5pm Fri Outside UK please call +44 121 694 5000 Email: events@sccb.ac.uk
More informationMAC Series. MAC Encore Wash MAC Encore MAC Encore Performance. MAC Encore Wash WRM - EPS. MAC Encore Performance WRM - EPS. MAC Encore Wash CLD - EPS
MAC Series MAC Encore Wash MAC Encore MAC Encore Performance MAC Encore Wash WRM MAC Encore Performance WRM MAC Encore Performance WRM integrates cutting-edge LED technology with a proprietary and innovative
More informationWaterside. Robert Bolt Theatre. Technical Rider
Waterside Robert Bolt Theatre Technical Rider 1 Waterside Plaza Sale Waterside Sale Cheshire M33 7ZF (Updated 24.11.2017) Robert Bolt Theatre- Summary Get In- Via Main Entrance No stairs. Smallest door
More informationTECHNICAL RIDER AUDIO - MAINSTAGE F.O.H. CONSOLE F.O.H. DRIVE MONITOR SPEAKER MONITOR CONSOLE P.A. LINE ARRAY 4 WAY
AUDIO - MAINSTAGE TECHNICAL RIDER P.A. LINE ARRAY 4 WAY F.O.H. CONSOLE F.O.H. DRIVE MONITOR SPEAKER MONITOR CONSOLE 16 PROEL AXIOM AX3210P Diffusor Line Array 3 way Bi-amp, Driver 1x10 LF 1x4 MF 1x2 HF,
More informationRogue R2 Spot DMX Chart. DMX Values. 21CH Channel Function Value Percent/Setting. 1
DMX Values 1 Pan 000 255 0 100% 2 Fine Pan 000 255 0 100% 3 Tilt 000 255 0 100% 4 Fine Tilt 000 255 0 100% 5 Pan/Tilt Speed 000 255 0 100% 6 Dimmer 000 255 0 100% 7 Fine Dimmer 000 255 0 100% 000 003 Closed
More informationCENTRO CULTURAL DE BELÉM FOUNDATION PEQUENO AUDITÓRIO TECHNICAL FILE
CENTRO CULTURAL DE BELÉM FOUNDATION PEQUENO AUDITÓRIO TECHNICAL FILE INDEX INDEX 1 INTRODUCTION 2 STAGE CONFIGURATION 2 ELECTRICAL POWER SUPPLY 2 FLYBAR SYSTEM 3 STAGE EQUIPMENT 3 ORCHESTRA FURNITURE 3
More informationCAPACITY 650 Kapelstraat 13, 5401 EC Uden PHONE 0031 (0) FAX 0031 (0) IMPORTANT NOTES PROHIBITED SMOKING
VENUE DE PUL HALL MAIN HALL CAPACITY 650 ADDRESS Kapelstraat 13, 5401 EC Uden PHONE 0031 (0)413-265091 FAX 0031 (0)413-266125 WEB www.livepul.com PROHIBITED SMOKING GET-IN SETTLEMENT LOCAL CREW SECURITY
More informationMANDURAH PERFORMING ARTS CENTRE BOARDWALK THEATRE. Stage & Auditorium Specifications
MANDURAH PERFORMING ARTS CENTRE BOARDWALK THEATRE Email: tech@manpac.com.au Phone: 08 9550 3911 TECHNICAL STAFF CONTACT Alexander Dick Peter Lovell Clinton Gerard Technical Supervisor Audio Technician
More informationTechnical Specification 2017
Technical Technical For further information please contact Millfield.Technical@Enfield.gov.uk Technical Department:0208 887 7315 www.millfieldtheatre.co.uk,, Updated: February 2016 Technical Seating Capacities:
More informationThe ideal replacement solution to the VL3000 Series spot or any other 1,000W to 1,500W lamped professional moving spot light.
The ideal replacement solution to the VL3000 Series spot or any other 1,000W to 1,500W lamped professional moving spot light. The Vari-Lite VLZ Profile is a dedicated profile luminaire utilizing the latest
More informationQUICK REFERENCE GUIDE
Main Level Programming Levels Description Pan Reverse Reverse pan operation Normal pan operation Tilt Reverse Reverse tilt operation Normal tilt operation Screen Rev Normal control screen view Rotates
More informationTradition Redefined. LED Theatre spots by. Tradition Redefined. Infinity Signature series
LED Theatre spots by The New Standard for Theatre Illumination. The tools you have always wanted to create beautiful, energy efficient lighting for your Theatre, Church, Studio or School. These luminaires
More informationTHÉÂTRE MAISONNEUVE. UPDATED - February 2019
UPDATED - February 09 The technical documentation of the venue that includ stage, sound or lighting is not list as a contract. Contact the technical department for an update on this document. General Informations
More informationPHOTOMETRIC DATA OUTPUT
THE TOUCH OF LIGHT UKEwihiq3K3efZAhXFCuwKHUkWAd0QMwhVKAUwBQ..i&w=1800&h=1322&client=firefox-b-ab&bih=943&biw=1920&q=fu HIGH POWER COMPACT LED MOVING HEAD WITH BUILT-IN ROTATING FRAMING SYSTEM oco&ved=0ahukewihiq3k3efzahxfcuwkhukwad0qmwhvkauwbq&iact=mrc&uact=8
More informationDMX-CONTROL OF MOTORISED DIMMER SHUTTER AND LAMP IGNITION
RJ NET FOR COMPACT FOLLOWSPOT RANGE Manual 1149B SUPER KORRIGAN 1449B LUCY 1159B VICTOR 1459B FLO DMXCONTROL OF MOTORISED DIMMER SHUTTER AND LAMP IGNITION Product version : "LUCY" 1449 : V3 "SUPER KORRIGAN"
More informationRobert Bolt Theatre. Technical Rider
Robert Bolt Theatre Technical Rider 1 Waterside Plaza Sale Waterside Sale Cheshire M33 7ZF (Updated 05.11.2014) Quick List Robert Bolt Theatre Get In- Via Main Entrance No stairs. Smallest door to reach
More informationDMX Channel Index. Software v
DMX Channel Index Software v. 28-40-31-27 GLP impression E350 DMX Channel Index Revision A This user manual covers fixture software version v. 28-40-21-27 2018 German Light Products GmbH. All rights reserved.
More informationPrice List for Lease of Facilities and Equipment of the Concert Hall Great Amber
Price List for Lease of Facilities and Equipment of the Concert Hall Great Amber Great Hall Specification total area 1170 m 2 ceiling height 23.70 m Inclined floor with a possibility to level the stalls
More informationPowerBar 4 Manual SAFETY NOTES WARNING! IMPORTANT:
PowerBar 4 Manual Thank you for purchasing this LITECRAFT product. For your own safety, please read the instruction manual carefully before turn on the product for the first time. SAFETY NOTES Each person
More informationNOTTINGHAM LAKESIDE ARTS DJANOGLY THEATRE TECHNICAL INFORMATION
If we do not receive your technical requirements and a lighting plan on Lakeside s plan at least four weeks before your visit, pre-rigging cannot be guaranteed. Please note that we will not pre-rig using
More informationLIGHTING INVENTORY. 517 Yeading Lane Northolt Middlesex UB5 6LN UK +44 (0)
INTELLIGENT/LED FIXTURES Vari*Lite 3000 Spot Luminaire Clay Paky Sharpy Clay Paky Sharpy Wash 330 Clay Paky Alpha Spot HPE300 Profile Martin MAC Viper Profile Martin MAC Viper Profile White Head & Yoke
More informationRogue R1 Spot DMX Chart. DMX Values. 19CH Channel Function Value Percent/Setting. 1
DMX Values 1 Pan 000 255 0 100% 2 Fine Pan 000 255 0 100% 3 Tilt 000 255 0 100% 4 Fine Tilt 000 255 0 100% 5 Pan/Tilt Speed 000 255 0 100% 6 Dimmer 000 255 0 100% 7 Fine Dimmer 000 255 0 100% 8 Shutter
More informationLast Updated January 2018
Last Updated January 2018 I CONTACTS Staff Technical Manager: Chris Gaughan Telephone: +353 21 490 5209 Mobile: +353 86 601 8517 Email: cgaughan@corkoperahouse.ie Stage Manager: Declan O Mullane Telephone:
More informationJockey Club Auditorium - Technical Information
Jockey Club Auditorium - Technical Information General Set-up Jockey Club Auditorium operates on a bare-walls touring policy. That is, all equipment is normally set-up and struck within the booking period.
More informationAlice Compact - LED 600W. Followspot. Type: Followspot Source: LED 600W Optics: 13 to 24 zoom Colour temperature: Cool White.
f Alice - 1469 Compact - LED 600W Type: Followspot Source: LED 600W Optics: 13 to 24 zoom Colour temperature: Cool White Followspot Too bright to ignore! Alice is proof that Robert Juliat continues to
More informationUsed Gear For Sale. Price includes 4 way case. Sold in case quantities only. Price includes 4 way case. Sold in case quantities only.
Sharpy Wash 330 Compact, lightweight washlight, with luminous efficiency, graphic and optical performance of a 1000W fixture includes 4 way 20 Excellent 45x31x27 219.8 lbs 2013 $3,000.00 Platinum Beam
More informationCANOLUX 65 INTERIOR LIGHTING MODEL NUMBER Y117 - CANOLUX 65 SPECIFICATIONS
CANOLUX 65 MODEL NUMBER Y117 - CANOLUX 65 SPECIFICATIONS HOUSING : Die cast and extruded aluminium. HEAT SINK : Aluminium extrusion, anodised black. LIGHT SOURCE : The fitting is designed to operate a
More informationTennessee Williams Theatre
Technical Specifications (Updated 02-15-2011) Stage Stage Floor Sprung pine covered with masonite Dance Floor..5 panels of marley flooring (5' x 45' Panels) Proscenium Opening...48-2 Proscenium Height...26-8
More informationDonald W. Reynolds Performance Hall Technical Information for Touring Companies
Donald W. Reynolds Performance Hall Technical Information for Touring Companies General Information Mailing Address UCA Public Appearances 201 Donaghey Avenue Stanley Russ Hall 225 Conway, AR 72035 Street
More informationArko Arts Theater Main Hall. 2. Lighting
1 Arko Arts Theater Main Hall 2. Lighting 1. System Diagram 2. Lighting Equipment 3. Lighting Hanging Position 1) 1, 2 FOH(Ceiling) & Balcony 2) Box boom & Slot &Proscenium Tower 3) Proscenium & Electric
More informationXicato Affordable XIM Quality Dimming
Xicato Affordable XIM Quality Dimming 2014 10 22 Grieg Hall in Bergen, Norway, Xicato Artist Series Lighting Design by Kim E. Hughes, Bright Norway, Luminaires by Roblon XIM Overview Better quality of
More informationDMX Chart Force 120. Firmware Version
DMX Chart Force 120 Product Information Firmware Version 1.25 support@glp.de www.glp.de GLP German Light Products GmbH Industriestr. 2, 76307 Karlsbad, Germany Tel: +49 (0)72 48 / 927 19 0, Fax: -30, E-Mail:
More informationMAIN HOUSE TECHNICAL RIDER
FT version du 28/09/15 MAIN HOUSE TECHNICAL RIDER ENGLISH VERSION HOUSE page 2 / 10 587 seats on tier 4 public access at upper and lower row level Acousticaly treated ceiling CATWALKS AND TECHNICAL GALLERY
More informationTechnical Specifications Alhambra Stage
Technical Specifications Alhambra Stage TECHNICAL DEPARTMENT CONTACTS : - Technical Manager : Mr. Vincent Collin +41.22.418.36.10 / +41.79.203.99.82 - vincent.collin@ville-ge.ch - Lighting Technician :
More informationTechnical specifications Short Format Subject to alteration-please call us to confirm details.
1. Belmont Street, Bognor Regis West Sussex. PO21 1BL tech@regiscentre.co.uk iain.jordan@regiscentre.co.uk Tel / Fax: 01243 867676 Box Office: 01243 861010 Technical specifications Short Format Subject
More informationGreenwood Theatre. Technical Specification. Greenwood Theatre. Technical Specifications October 2016 Page 1 of 11
Technical Specification Technical Specifications October 206 Page of October 206 Table of Contents Table of Contents 2 Contact Details 3 Seating Capacity 3 Access 4 Stage Information & Dimensions 4 Flying
More informationUSER S MANUAL. This manual must be considered an integral part of the projector. The user must read this manual before using the projector
575W HMI Scan light ZIPPER 575 USER S MANUAL This manual must be considered an integral part of the projector. The user must read this manual before using the projector AUTHORISED AND QUALIFIED PERSONNEL
More informationthe coemar LED experience
the coemar LED experience LED technology has been part of the entertainment lighting industry since the mid-9s. Originally as a simple power on light indicator, LED lights have evolved to become a versatile,
More informationGCSE Applied Performing Arts
Section B Lighting Workshop Page Number Content of Page Planning & Research Skills Development Work related aspects Evaluation Page 1 Front Cover Page 2 First Audit Sheet ü ü Page 3 Flood Lantern ü ü Page
More informationLedison LED Troffer Light Back Lit Structure
Ledison LED Troffer Light Back Lit Structure Ledison Lighting, has announced the new recessed PNL-BL6060 LED Troffer Light with embedded driver, which has now joined the company's popular range of LED
More informationRogue R2 Beam DMX Chart. DMX Values. 18CH Channel Function Value Percent/Setting. 1
DMX Values 1 Pan 000 255 0 100% 2 Fine Pan 000 255 0 100% 3 Tilt 000 255 0 100% 4 Fine Tilt 000 255 0 100% 5 Pan/Tilt Speed 000 255 0 100% 6 Dimmer 000 255 0 100% 7 Fine Dimmer 000 255 0 100% 000 007 Closed
More informationTheatre Technical Specifications
Theatre Technical Specifications Seating Capacity: The Lakes Theatre STAGING INFORMATION Total 1200 seats Stage Dimensions: Width at widest Part 18m Rear stage width- 13m Stage depth (at centre) 7.4m Height
More information2016/2017 Technical Specifications. FOH Sound System. FOH Mains: 2- Meyer MSL-4 (1 Above, 1Below) + 1- Meyer DF-4P per side
2016/2017 Technical Specifications FOH Sound System FOH Mains: 2- Meyer MSL-4 (1 Above, 1Below) + 1- Meyer DF-4P per side 2- Meyer PSW-2 Dual 15 Subwoofers 2- Meyer UPM-1P Center Fills (Optional) 25- TOA
More informationTECHNICAL EQUIPMENT INFORMATION THE NORMAN ROTHSTEIN THEATRE Updated: November 2018
Stage Specifications: Stage Dimensions: Apron Dimensions: Proscenium Arch: Backstage Crossover: Wing space is limited Proscenium to upstage traveler 6.71 meters deep by 10.67 meters wide The apron down
More informationThe Theater at Colorado Heights
The Theater at Colorado Heights Theater Manager - Dennis Leach O: 303-937-4009 C: 720-985-4886 DLeach@CHU.edu Technical Coordinator Cullen Munch O: 303-937-4012 C: 303-570-6241 CMunch@CHU.edu Director
More informationPar Lights $54.95 EACH
Par Lights PAR 38 The par 38 is a very economical fixture. It is used mostly for up-lighting in small areas. With a 90W to 125W bulb it is not suitable for lighting large areas, but vignettes, buffet tables,
More informationPRODUCT SPECIFICATIONS
FOS Hallo LED 1 PRODUCT SPECIFICATIONS TECHNICAL SPECIFICATION Voltage: 100/240 Volt AC, 50/60 Hz. Light Source: 468 x 0,8 Watt LEDs in total, 50,000 life hours, 7000 Hz refresh rate. LED Groups: 8 RGB
More informationAdjustable beam angle LED bar DATASHEET EFFI-FLEX-CPT
Strobe version available Very intense and uniform illuminated area Full range of colors: from UV to IR, white, tricolor Long lifetime and few maintenance Standard connections and fasteners Flexible: Adjustable
More informationTechnical Specifications Black Box
Table of Contents 1. General Information: 2. Audio & Video: 3. Lighting: 4. Staging: 1.1. Equipment Set Up & Operation 1.2. Electrical Safety 1.3. Power Supply 2.1. Mixing Console 2.2. Playback 2.3. Standard
More informationTallinn Concert Hall. Venue location : Tallinn, Estonia Str 9, 10145, Estonia
Tallinn Concert Hall PA & LIGHTNING EQUIPMENT LIST Venue location : Tallinn, Estonia Str 9, 10145, Estonia N59 25 58 E24 45 9 info@kontserdimaja.ee Capacity: Floor 1029, 1st balcony 491, 2nd balcony 308
More informationJeanne and Peter Lougheed Performing Arts Centre
Facility Information Jeanne and Peter Lougheed The Jeanne and Peter Lougheed is located at 4501 50 th Street in Camrose, Alberta. We are situated on the University of Alberta Augustana Campus, alongside
More informationCreating Custom Fixtures
Application Note Introduction There are two types of custom fixture available within Designer: Alias Fixtures Custom Fixtures The difference between these is that an Alias fixture is a copy of a fixture
More informationArtistic Licence. Rail-Pipe HC. User Guide. Version 1-6. Rail-Pipe HC User Guide
Artistic Licence Rail-Pipe HC User Guide Rail-Pipe HC User Guide Version 1-6 Please read these instructions before using the product. This product has been designed & manufactured for professional use
More informationVenue info Studentersamfundet, Trondheim, Norway
Venue info Studentersamfundet, Trondheim, Norway Update: 11.jan.2017 Venue Capacity Venue type Address Parking Load in Stage Dressing rooms Internett Mixer position House PA Power Klubben (the Club) 300
More informationTransmitter: touch switch and dimmer, 1 zone, intelligent, RF signal transmission Compatible with the receivers TRE-P and TRE-P
CONTROL ELECTRONICS LED lighting control CONTROL SYSTEMS TRE-V1-0101-F - Touch dimmer, 1 zone Transmitter: touch switch and dimmer, 1 zone, Compatible with the receivers code: 00203209 Receiver TRE-P1-0101-8:
More informationTECH RIDER 7 DAYS IN ALASKA
1 av 5 TECH RIDER 7 DAYS IN ALASKA Contacts Kickstart Booking: Band og technician: Jørgen Bertelsen Ole Gunnersen jorgen@ksbooking.no ole@gunnersen.no tlf: +47 980 34 060 tlf: +47 950 93 843 This rider
More informationNo compromise, simply brighter
MAC 2000 Wash XB No compromise, simply brighter The MAC 2000 Wash XB takes the proven qualities of the world s favourite wash light, the MAC 2000 Wash, and adds even greater brightness without compromising
More informationMerlin Touring W HMI. Followspot. Type: Followspot Source: 2500 W HMI PSU: Electronic - hot restrike - DMX Optics: 3 to 12 zoom
f Merlin - 1515 Touring - 2500 W HMI Type: Followspot Source: 2500 W HMI PSU: Electronic - hot restrike - DMX Optics: 3 to 12 zoom Followspot The new touring machine for rentals Mixing a stainless steel
More informationSee the lakeside website for up-to-date tech spec and drawings
Updated Sept 208 General Venue Information See the lakeside website for up-to-date tech spec and drawings https://www./technical.html 0m x 0m Maximum Performance Area Dimensions (See Ground Plan for Details)
More informationAdjustable beam angle LED bar
Strobe version available Very intense and uniform illuminated area Full range of colors: from UV to IR, white, tricolor Long lifetime and few maintenance Standard connections and fasteners Flexible: Adjustable
More informationLED LL DP CD WW CS CF AC CG. Wall Washer CB LC FO EL
LED Projectors LED LL DP CD WW CS CF AC CG Wall Washer The wallwasher series offers ideal lighting solutions for indoor and outdoor venues. These luminaires are utilised for the purpose of illuminating
More informationBedford Corn Exchange main Auditorium
Bedford Corn Exchange main Auditorium Technical information AUDIO 10) TTL33-A line array module The TTL33 line array module is a wide, constant directivity, coverage angle, with six high power neodymium
More information10178 Case for GoPro 5 camera $20
Case Case 10113 DB Microphone cases 10114 Mic cases 4 empty Less for CASH $5ea $10 CD 10029 CDs various includes Karaoke discs $5ea - 10 for $40 GoPro 10177 Water proof Housing for GoPro Hero 5 ea. GoPro
More informationDMX Channel Index. X4 Bar 10. from software version: v0.26.
DMX Channel Index X4 Bar 10 from software version: v0.26 support@glp.de www.glp.de 1 Normal Mode (norm) 33 DMX Channels: Channel Function Time and Value DMX 1 Tilt - High Tilt coarse 0-210 0..255 2 Tilt
More informationN DI TECHNICAL RIDER PHOTO : SÉBA. imperialbell.com
PHOTO : SÉBA PHOT SÉBASTIE STIEN STIE N DI DION TECHNICAL RIDER A PROPERTY OF ADRESS 252, rue Saint-Joseph Est Québec (Québec) MANAGEMENT 240, rue Saint-Joseph Est Québec (Québec) G1K 3A9 General phone:
More informationDrama Studio Technical Guide
Drama Studio Technical Guide Drama Studio Lighting Rig - This is the structure which lanterns (lights) and other items are suspended from. In our Drama studio it is split into 9 squares. You can also see
More informationINFINITI Monochromatic Power LED
INFINITI Monochromatic 523-1023 - 1523-2023 PRODUCT DESCRIPTION: High performance professional lighting system for indoor and outdoor wall grazing. Built in power supply and advanced optical glare control.
More informationSUB & BASS DB TECHNOLOGIES 15 ACTIF 20,00 BEYMA 18 15,00 L ACOUSTICS SB ,00 FLOOR MONITORS AK W152 20,00 SPEAKER STAND SPEAKER STAND 2,50
V4 SOUND FULL RANGE & TOP QSC K12 17,50 OHM MR228 12,00 DAS R115 20,00 DAS MI112 12,00 DB TECHNOLOGIES OPERA 12 15,00 JBL 4922 20,00 L-ACOUSTICS ARCS 40,00 L-ACOUSTICS MTD 108 25,00 Syncq SC05 (novembre
More informationLUNATION TOUR Technical Specifications
LUNATION TOUR Technical Specifications 0 Lunation Tourı PRESTATION // PERFORMANCE 2 artistes sur scène / 2 performers on stage: - Philippe Fagnoni Keyboards & computers - Oriane Alaphilippe AstroVoyager's
More informationTHÉÂTRE JEAN-DUCEPPE
Updated - October 207 The technical documentation of the venue that include stage, sound or lighting equipment is not part of the contract. Contact the technical department for an update on this Informations
More informationCENTRO CULTURAL DE BELÉM FOUNDATION GRANDE AUDITÓRIO TECHNICAL FILE
CENTRO CULTURAL DE BELÉM FOUNDATION GRANDE AUDITÓRIO TECHNICAL FILE INDEX INDEX 1 INTRODUCTION 2 STAGE CONFIGURATION 3 ELECTRICAL POWER SUPPLY 3 FLYBAR SYSTEM 4 STAGE EQUIPMENT 4 ORCHESTRA PIT 4 ORCHESTRA
More informationTechnical Specifications Alhambra Stage
Technical Specifications Alhambra Stage TECHNICAL DEPARTMENT CONTACTS: Technical Manager: Mr.Vincent Collin +41.22.418.36.10/+41.79.203.99.82 Lighting Technician: Mr.Frédéric Fellmann +41.22.418.36.09/+41.79.476.69.10
More information