USER S MANUAL. This manual must be considered an integral part of the projector. The user must read this manual before using the projector

Size: px
Start display at page:

Download "USER S MANUAL. This manual must be considered an integral part of the projector. The user must read this manual before using the projector"

Transcription

1 575W HMI Scan light ZIPPER 575 USER S MANUAL This manual must be considered an integral part of the projector. The user must read this manual before using the projector

2 AUTHORISED AND QUALIFIED PERSONNEL ONLY, IN COMPLIANCE WITH ALL THE SECURITY LAWS, CAN DO THE INSTALLATION, THE MAINTENANCE AND THE UTILISATION OF THIS PROJECTOR. BEFORE CONNECTING THE PROJECTOR, MAKE SURE THAT THE FREQUENCY AND THE VOLTAGE VALUES ARE SUITABLE AS SPECIFIED ON THE PROJECTOR. DO NOT OPEN THE PROJECTOR IF IT IS CONNECTED TO THE MAIN SUPPLY. FOR ANY DOUBT, CONTACT YOUR SUPPLIER OR SEND AN TO:

3 Dimensions & weight Weight: 20.5Kg Technical data - HMI 575 lamp - Magnetic ballast with power factor correction (3.7A 230VAC with lamp ON) - DMX controlled or stand alone mode - PAN 200 8/16 bit, TILT 80 8/16 bit - 6 ROTATING GOBOS + W, interchangeable, with index adjustment, can rotate clockwise and counter-clockwise. - 9 FIXED GOBOS + W - 9 COLOURS + W - Motorized FOCUS - Linear DIMMER 0 100% - STROBE run s up to 10 flashes per second - PRISM x3 with adjustable rotation clockwise and counter-clockwise - Optics cm 2mt 4mt 6mt 8mt 80cm 40cm 0cm 40cm 80cm 120cm Lux (optics 14 ) Diam. (cm)

4 DMX512 specifications CH. DMX FUNCTION 01 Dimmer The projector reads normally 14 consecutive 02 Shutter/Strobe DMX channels starting from the set address. 03 Focus 04 Colour 05 Pan (HSB) 06 Tilt (HSB) The REMOTE CONTROL is active depending 07 Gobo 1 selection Of the status of REMOTE option (INDEX 9) 08 Gobo 1 index position 09 Gobo 1 rotating speed 10 Prism (insertion/speed) 11 Remote control 12 Pan (LSB) only if HIGHRES=1 13 Tilt (LSB) only if HIGHRES=1 14 Gobo FIXED selection 01 DIMMER Controls the intensity of the light beam from 0 to 255. It also works during the Strobe function. The value of this channel is ignored if the shutter channel is in the CLOSE position. Open Proportional Intensity Min... Max Close SHUTTER/STROBE Selects blackout, channel open and strobe functions. With the SHUT ON COLOUR function selected, the shutter closes during the colour change. With the SHUT ON GOBO function selected, the shutter closes during the gobo change. Open Close Blackout (It has priority over the dimmer) Strobe Maximum rate Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Minimum rate Close 0..7 Blackout (It has priority over the dimmer)

5 03 FOCUS Controls the focus adjustment. With the DEFOCUS ON CHANGE option selected, the generated image goes out of focus during an effect change. Max (far) Proportional Min 0..3 (near) 04 COLOURS The channel selects the pre-set fixed positions (white + 9 full colours). If the SHUT ON COLOUR option is activated, the shutter is closed during the colour change. C C C C C C C C C WH /06 - PAN & TILT (8 bit) The Pan/Tilt movement is controlled by the received values on the Pan and Tilt channels. If the HIGHRES option is activated, the Pan and Tilt Fine extra channels set the real position of the Pan and Tilt movement in a fine way (5/6 + 12/13). If the REVERSE PAN and/or REVERSE TILT options are activated the Pan and/or Tilt movement directions are inverted. If the PANTILT SWAP option is activated, the Pan and Tilt functions swap between themselves. 07 GOBO 1 SELECTION It selects the rotating gobo preferred or no gobo at all. The angle desired or the speed and the way of rotation are indicated from other channels (Angle, Speed Rotating Gobo). If the SHUT ON GOBO option is activated the shutter is closed during the gobo change. If the DEFOCUS ON CHANGE option is activated, the projected image goes out of focus during the gobo change. Gobo Gobo Gobo Gobo Gobo Gobo Gobo GOBO 1 INDEX Assigns to the gobo a position in the range of 360. The SHUT ON GOBO or the DEFOCUS ON CHANGE options has no effect in case of variation on this channel.

6 09 GOBO 1 ROTATION SPEED It selects the speed and the rotation way of the selected gobo from the Gobo Selection channel. The SHUT ON GOBO or the DEFOCUS ON CHANGE options has no effect in case of variation on this channel. If the REMOTE ENABLE option is not activated the AUX channel increases resolution of this channel. Stop The GOBO holds the position assigned with the Gobo Index channel Clockwise Rotation From maximum (130) to minimum (251) speed Not valid values, no effects Counter-clockwise From minimum (4) to maximum (125) speed Rotation Stop 0..3 The GOBO holds the position assigned with the Gobo Index channel 10 PRISM INSERT/ROTATION It selects the insertion and the speed of the prism rotation. The SHUT ON GOBO and the DEFOCUS ON CHANGE options have no effects in case of variation on this channel. Prism Out Prism In Insert still Clockwise Rotation From maximum (130) to minimum (247) speed Not valid values, no effect Counter-clockwise From maximum (8) to minimum (125) speed Rotation. Prism In 4..7 Insert still Prism Out AUX / REMOTE If the REMOTE ENABLE option is not activated, the channel performs the fine control of the speed of the rotating gobo. If the REMOTE ENABLE option is activated, the channel sends, via DMX, special codes to the projector, as LAMP ON/OFF, RESET and SET-UP. 12/13 - PAN & TILT (16 bit) If the HIGHRES option is activated, the Pan and Tilt Fine extra channels set the real position of the Pan and Tilt movement in a fine way (5/6 + 12/13). 14 GOBO FIXED SELECTION It selects the gobo preferred (9 gobos+ no gobo) or no gobo at all. If the SHUT ON GOBO option is activated the shutter is closed during the gobo change. If the DEFOCUS ON CHANGE option is activated, the projected image goes out of focus during the gobo change. GOBO GOBO GOBO GOBO GOBO GOBO GOBO GOBO GOBO OPEN 0..27

7 User s interface Press and release the push-button MODE to access the different functions, as indicated by the three LED Index (green led on): see the table in the next page for the meaning. Use the + or - button to select the number of the Index. Parameter (yellow led on): Use the + or - button to select the value of the Parameter which must be checked or modified. To enable a modification, press the ENTER button; the display will flash twice as confirmation. Fault (red led flashing): it is possible to access this mode only if a fault has happened. When the cause of the fault will be removed, the indication will be automatically removed too. It is also possible to remove some fault indication, pressing the ENTER button. Pressing the - button it is possible to see how many faults are enabled (in this case the red LED stops flashing), pressing the + button, the system returns to the visualization of the current fault code. Automatic return to the default visualization: if no buttons are pressed for more than 30 seconds, the system automatically returns back to the default visualization: the DMX INDEX, if there aren't faults, or the current fault code. Permanent visualization of a fault, when existing: when a fault has happened, even if the Index or the Parameter mode have been enabled, the red "LED" stay on. Start-up codes: when the projector is switched on, the display visualised in a sequence, 2 codes that identify the software of the main electronic board: first the Device Code (example: Zipper #003) and second the Software Release (example: 1.05). Procedures of zero: when a start procedure is going on, the display will show only one 0 on the middle digit. Special function system: when the projector runs special functions, the 3-digit display flashes the same number Calibration of start positions Calibration of the gobo 2 position Remote control of the parameters

8 Parameters The parameters Boolean type (min=0, max=1) enable the controlled function when their value is 1 and they unable it when their value is 0. The Index n 12 and n 16 depend on the hardware configuration. Index Description Parameter NAME EFFECT Min Default Max 0 DMX INDEX Sets the DMX address of the projector PANTILT SWAP Exchanges the assignment of the DMX channels between PAN & TILT 2 REVERSE PAN Reverses the PAN movement 3 REVERSE TILT Reverses the TILT movement 4 SHUT ON COLOUR Closes the shutter before to change the colour, then re-open it 5 SHUT ON GOBO Closes the shutter before to change the gobo, then re-open it 6 DEFOCUS ON CHANGE The image goes out of focus before to change the colour or the gobo, or before the prism is enabled or disabled, then returns on focus 7 HIGHRES Enables the high resolution mode (16bit) for the PAN & TILT channels 8 PANTILT SOFT Progressive softening of the Pan & Tilt short movement when the parameter decreases 9 REMOTE ENABLE Enables the possibility to remote control the parameter of the projector via DMX 10 SYNCRO STROBE Selects the strobe mode Continuous strobe = 0: does not guarantee the synchronism of 2 or more projectors driven with the same DMX value; it can be used while programming Strobe sync. = 1 12 RESET COLOR Enables the manual reset of the colour wheel (the parameter is automatically reset at the end of the procedure) 13 RESET GOBO Enables the manual reset of the gobo wheel (the parameter is automatically reset at the end of the procedure) 14 RESET Enables the manual reset of the system (the parameter is automatically reset at the end of the procedure) 16 PROGRAM Enables the STAND ALONE function and sets the number EXECUTION of STEPS to execute into the loop 17 PROGRAM STEP Determines the current STEP of the inside program to which STEP SLOPE and STEP HOLD referred to 18 STEP SLOPE Determines the time, in seconds, of the slope before the current STEP 19 STEP HOLD Determines the time, in seconds, of the current STEP duration 20 LAMP LIFE Shows the life time, in hours, of the lamp Press the ENTER button to clear the counter

9 Remote Control If the REMOTE ENABLE parameter (Index n 10) is equal to 1, it is possible to modify or activate some functions of the projector, via DMX. The activation of controls is based on a precise time sequence of the DMX channels values, if a step of the sequence is wrong the sequence will be deleted and it will be necessary start from the beginning the sequence. The parameters All the STEPS of the following table must be executed. STEP DMX channels status Timing Action 1 CH1..CH11 = 0 4sec<time CH1..CH10 = 0 CH11 = CH1..CH10 = 0 CH11 = 0 4 CH1..CH10 = 0 CH11 = CH1..CH10 = any CH11 different from 0 and from 255 2sec<time The display flashes the number 222 to show the entrance in the parameters remote control. If the value of the DMX channel is minor than 9, the parameter will remain the same, if it is inclusive between 9 to 128, the parameter will be equal to 0, and if it is greater than 128, the parameter will be equal to 1. The PANTILT SOFT parameter is an exception as follow: If the value of the DMX channel is minor than 100, the parameter will remain the same, if it is inclusive between 100 to 200, the parameter will be equal to DMX value 100, and if it is greater than 200, the parameter will be equal to CH1..CH10 = any CH11 = 0 The coupling of the parameters and the DMX channels is as follow: PANTILT SWAP CH1 REVERSE PAN CH2 REVERSE TILT CH3 SHUT ON COLOUR CH4 SHUT ON GOBO CH5 DEFOCUS ON CHANGE CH6 HIGHRES CH7 PANTILT SOFT CH8 RESET CH The display will return to the usual visualized condition, to signal the exit from the remote control. The values of the DMX channels at the moment of the exit from the remote control condition will modify in a permanent way the parameters to which those are coupled. N.B. if the parameter RESET has been set at 1 will be executed a global reset procedure of the projector. These procedures can be enabled only if a fault happened during the search of the zero for the colour wheel, the gobo wheel and the gobo 1 position (fault code 22,23,24); in this case the parameter REMOTE CONTROL is forced to 1 and the device with the fault, will work on temporary mode. The DMX channel will work as a linear positioning, proportional to the value. When the remote insertion of the zero will be done, the channel will go back to normal mode.

10 Remote insertion of the zero positions All the STEPS of the following table must be executed. Insertion of the colour wheel zero STEP DMX channel status Timing Action 1 44<CH1<84 (25%) 108<CH11<148 (50%) 2 44<CH1<84 (25%) CH11=255 (100%) 3 44<CH1<84 (25%) CH11=0 (0%) The position of the colour wheel is recorded as zero position and the channel goes back to normal mode. All the STEPS of the following table must be executed. Insertion of the gobo 1 wheel zero STEP DMX channel status Timing Action 1 108<CH1<148 (50%) 108<CH11<148 (50%) 2 108<CH1<148 (50%) CH11=255 (100%) 3 108<CH1<148 (50%) CH11=0 (0%) The position of the gobo 1 wheel is recorded as zero position and the channel goes back to normal mode. All the STEPS of the following table must be executed. Insertion of the gobo index zero STEP DMX channel status Timing Action 1 172<CH1<212 (75%) 108<CH11<148 (50%) 2 172<CH1<212 (75%) CH11=255 (100%) 3 172<CH1<212 (75%) CH11=0 (0%) The initial index of the gobos is recorded as zero position and the channel goes back to normal mode. All the STEPS of the following table must be executed. Insertion of the gobo 2 wheel zero STEP DMX channel status Timing Action 1 240<CH1 (100%) 108<CH11<148 (50%) 2 240<CH1 (100%) CH11=255 (100%) 3 240<CH1 (100%) CH11=0 (0%) The position of the gobo 2 wheel is recorded as zero position and the channel goes back to normal mode.

11 Calibration procedures WARNING! USE THE CALIBRATION PROCEDURES CAREFULLY AND ONLY WHEN NECESSARY. Calibration of the reset positions (Gobos 1 and colours) Press the MODE and ENTER button together, for at least 5 seconds, until when the display will show 000 flashing. The DMX channel from 1 to 3 will give the value of the offset to add, or subtract, to the zero position DMX FUNCTION VALUE 1 Offset COLOUR wheel DMX channel = 0 offset = minus 4 steps 2 Offset GOBO 1 wheel DMX channel = 128 offset = 0 3 Offset GOBO position DMX channel = 255 offset = plus 4 steps To exit the calibration mode press ENTER: the set values will be stored. Calibration of the reset positions (fixed gobos wheel) Press the MODE and + button together, for at least 5 seconds, until when the display will show 111 flashing. The DMX channel 1will give the value of the offset to add, or subtract, to the zero position DMX FUNCTION VALUE 1 Offset GOBO 2 wheel DMX channel = 0 offset = minus 4 steps DMX channel = 128 offset = 0 DMX channel = 255 offset = plus 4 steps To exit the calibration mode press ENTER: the set values will be stored. Faults If the microprocessor finds a functional fault, it stores and shows that on the display. Can be stored up to a maximum of 5 codes of fault. Some faults can reset automatically as soon as disappear the cause that generated them, and some others have to be manually reset, pressing the ENTER button in the fault mode. CODE CAUSE EFFECT RESET 5 Absence of DMX signal The system wait for the signal Automatic 22 The zero COLOUR wheel sensor fault The COLOUR wheel will work on temporary mode (linear positioning of the wheel referred to the corresponding DMX channel) until when will Manual 23 The zero GOBO 1 wheel sensor fault 24 The zero GOBO 1 position sensor fault 25 The zero GOBO 2 wheel sensor fault be inserted, via remote control, the zero position. The GOBO 1 wheel will work on temporary mode (linear positioning of the wheel referred to the corresponding DMX channel) until when will be inserted, via remote control, the zero position. The GOBO 1 wheel will work on temporary mode (linear positioning of the wheel referred to the corresponding DMX channel) until when will be inserted, via remote control, the zero position. The GOBO 2 wheel will work on temporary mode (linear positioning of the wheel referred to the corresponding DMX channel) until when will be inserted, via remote control, the zero position. Manual Manual Manual

12 Inside program It is possible to create an inside program that allows the projector to function on "stand-alone" mode, so, it is not necessary to have a DMX controller to drive the projector. When the "stand-alone" function is enabled, the projector becomes a DMX generator which supply, via DMX line, the values corresponding to the inside program. WARNING!! To avoid conflicts of the DMX signal, if one projector is in this mode, it is necessary remove the connection with the DMX controller. The inside program runs a loop of up to 20 steps (PROGRAM STEP); each step contains: a DMX value of all the channels of the projector, a time slope to achieve the new step (STEP SLOPE) and a hold time of the step (STEP HOLD). Storing of the steps Via the DMX controller, give to the projector the position and the image required Set the value of STEP SLOPE (Index 18) to assign the time (in seconds) of the transition from the previous step to this new one Confirm with the ENTER button Set the value of STEP HOLD (Index 19) to assign the time (in seconds) of the hold time of this new step Confirm with the ENTER button Assign to the PROGRAM STEP parameter (Index 17) the number of the step you want memorize Push the ENTER button to store Execution of the inside program If the PROGRAM EXECUTION parameter (Index 16) contains "0", than the projector follows the command received from an external DMX controller, otherwise, if it contains a value between "1" and "20", than the projector execute a loop of steps from "1" to the number stored in the PROGRAM EXECUTION parameter N Modification of the program during execution If, during the execution of a program in "stand-alone" mode, you set a PROGRAM STEP value (Index 17) and then you push the ENTER button, the program in execution will jump directly to the step required. If, during the execution of a program in "stand-alone" mode, you set a STEP SLOPE value (Index 18) or a STEP HOLD value (Index 19) and then you push the ENTER button, the corresponding parameter of the step in execution will be modified. DMX Step 2 Step 1 Slope 1 Hold 1 Slope 2 Hold 2 Time

13 Lamp Replacement 1) Disconnect the projector from the main power supply 2) Unscrew the screws that hold the lamp cover 3) Remove the lamp cover 4) Remove the lamp, taking care to wear proper protective gloves 5) Insert a new lamp 6) Re-insert the lamp cover 7) Fix well all the screws that hold the lamp cover WARNING!! DISCHARGE LAMPS CONTAIN SUBSTANCES THAT CAN POLLUTE THE AMBIENCE. DISPOSE OF USING THE APPROPRIATE REFUGES (TOXIC). The improper use of this projector, cancel the guarantee and our responsibility. All the information have been written and driven with extreme care; however, we do not engage us any responsibility for contingent errors or omissions. We reserve the right to modify and/ or improve our product as we retain necessary, without subsequent warning or notice. It is forbidden any complete or partial reproduction of this handbook, if not expressly authorized.

Rogue R1 Spot DMX Chart. DMX Values. 19CH Channel Function Value Percent/Setting. 1

Rogue R1 Spot DMX Chart. DMX Values. 19CH Channel Function Value Percent/Setting. 1 DMX Values 1 Pan 000 255 0 100% 2 Fine Pan 000 255 0 100% 3 Tilt 000 255 0 100% 4 Fine Tilt 000 255 0 100% 5 Pan/Tilt Speed 000 255 0 100% 6 Dimmer 000 255 0 100% 7 Fine Dimmer 000 255 0 100% 8 Shutter

More information

Rogue R2 Beam DMX Chart. DMX Values. 18CH Channel Function Value Percent/Setting. 1

Rogue R2 Beam DMX Chart. DMX Values. 18CH Channel Function Value Percent/Setting. 1 DMX Values 1 Pan 000 255 0 100% 2 Fine Pan 000 255 0 100% 3 Tilt 000 255 0 100% 4 Fine Tilt 000 255 0 100% 5 Pan/Tilt Speed 000 255 0 100% 6 Dimmer 000 255 0 100% 7 Fine Dimmer 000 255 0 100% 000 007 Closed

More information

Rogue R2 Spot DMX Chart. DMX Values. 21CH Channel Function Value Percent/Setting. 1

Rogue R2 Spot DMX Chart. DMX Values. 21CH Channel Function Value Percent/Setting. 1 DMX Values 1 Pan 000 255 0 100% 2 Fine Pan 000 255 0 100% 3 Tilt 000 255 0 100% 4 Fine Tilt 000 255 0 100% 5 Pan/Tilt Speed 000 255 0 100% 6 Dimmer 000 255 0 100% 7 Fine Dimmer 000 255 0 100% 000 003 Closed

More information

QUICK REFERENCE GUIDE

QUICK REFERENCE GUIDE Main Level Programming Levels Description Pan Reverse Reverse pan operation Normal pan operation Tilt Reverse Reverse tilt operation Normal tilt operation Screen Rev Normal control screen view Rotates

More information

Introduction. Purpose

Introduction. Purpose Page 1 of 6 SUBJECT: VL1000 / VL2000 Luminaire Software SERIES: 1000/2000 DISTRIBUTION: Service Centers, End Users STATUS: Routine Introduction 10 minutes Purpose Software Version 4.8 containing updated

More information

VL1000 Software Version History VL1000 3/25/02 4/10/02 4/15/02 4/25/02 5/16/02 6/25/02 7/09/02 8/08/02

VL1000 Software Version History VL1000 3/25/02 4/10/02 4/15/02 4/25/02 5/16/02 6/25/02 7/09/02 8/08/02 Page 1 of 5 SUBJECT: VL1000 Luminaire Software Version History SERIES: 1000 DISTRIBUTION: Service Centers, End Users STATUS: Routine Introduction VL1000 Software Version History This technical bulletin

More information

DMX Channel Index. Software v

DMX Channel Index. Software v DMX Channel Index Software v. 28-40-31-27 GLP impression E350 DMX Channel Index Revision A This user manual covers fixture software version v. 28-40-21-27 2018 German Light Products GmbH. All rights reserved.

More information

ELATION PLATINUM 1200 WASH DMX Channel Values / Functions (93 Total DMX Channels) Supports Software Versions: 2.1.0

ELATION PLATINUM 1200 WASH DMX Channel Values / Functions (93 Total DMX Channels) Supports Software Versions: 2.1.0 10 6 11 12 13 17 18 20 21 22 23 24 1 1 1 2 2 2 3 3 3 5 4 4 6 4 7 8 5 9 14 15 16 19 5 6 7 8 9 10 11 12 PAN MOVEMENT [8 BIT] 0-255 PAN Movement PAN FINE MOVEMENT [16 BIT] 0-255 Fine Control of PAN Movement

More information

1. Safety instructions Control elements of the RoboSpot...4

1. Safety instructions Control elements of the RoboSpot...4 Version 1.4 Table of contents 1. Safety instructions... 3 2. Control elements of the RoboSpot... 4 2.1 RoboSpot... 4 2.2 FollowSpot Controller... 5 3. Installation... 6 4. RoboSpot connection... 8 5. Operation...

More information

Guangzhou Liangyi Lighting Equipments Co., Ltd.

Guangzhou Liangyi Lighting Equipments Co., Ltd. Guangzhou Liangyi Lighting Equipments Co., Ltd. 7 Gongyedadao,Xinhua, Huadu,Guangzhou PC: 50800 Tel : (00) 666 090 88-800 Fax: (00) 868 670 www.eklights.com USER MANUAL CONTENTS SAFETY DIMENSIONS DESCRIPTION

More information

DMX protocol. Robin SPIKIe - DMX protocol

DMX protocol. Robin SPIKIe - DMX protocol protocol Robin SPIKIe - protocol Version: 1.4 (version of processor m: 2.2 and higher) Mode 1-Standard 16-bit, Mode 2 -Reduced 8-bit Mode/channel 1 1 Pan (8 bit) 0-255 Pan movement by 540 /360 (128=default)

More information

PHOTOMETRIC DATA OUTPUT

PHOTOMETRIC DATA OUTPUT THE TOUCH OF LIGHT UKEwihiq3K3efZAhXFCuwKHUkWAd0QMwhVKAUwBQ..i&w=1800&h=1322&client=firefox-b-ab&bih=943&biw=1920&q=fu HIGH POWER COMPACT LED MOVING HEAD WITH BUILT-IN ROTATING FRAMING SYSTEM oco&ved=0ahukewihiq3k3efzahxfcuwkhukwad0qmwhvkauwbq&iact=mrc&uact=8

More information

VR8 - VR8R edition. Abstract Design to Light 1998 Tel:

VR8 - VR8R edition. Abstract Design to Light 1998 Tel: VR8 - VR8R Abstract Design to Light 1998 Tel:0116 278 8078 http://www.abstract-lighting.co.uk VR Instruction Manual - Issue 1.2: May 2000 Written for Abstract Design to Light by Sabre Technology Ltd: 01482

More information

R PROFLAME Instruction Book Collection

R PROFLAME Instruction Book Collection 9.956.028 R00 584 PROFLAME Instruction Book Collection 4-17 18-29 584 PROFLAME System 30-39 Appendix: DIP SWITCH NUMBER (0=ON 1=OFF) 40-41 4-17 Fig. 1 The SIT is a device that allows, in conjunction with

More information

Smart-house Dimmer Power dimmer up to 500W Type SH2D500W230

Smart-house Dimmer Power dimmer up to 500W Type SH2D500W230 Smart-house Dimmer Power dimmer up to 500W Type SH2D500W230 Universal dimmer switch for R, L, C up to 500W and LED loads Automatic load detection for L, R, C loads Integrated heat sink for temperature

More information

Via Pio La Torre, Tavullia (PS), Italy Tel Fax

Via Pio La Torre, Tavullia (PS), Italy Tel Fax A.D. e progetto grafico ACANTO Ph. AMATI E BACCIARDI I GB A000371 rel. 1.00 Via Pio La Torre, 1 61010 Tavullia (PS), Italy Tel. +39 0721 476477 Fax +39 0721 476170 http://www.sgm.it Email: info@sgm.it

More information

Distributor: Phone: Fax:

Distributor:  Phone: Fax: A.D. e progetto grafico ACANTO COMUNICAZIONE Ph. AMATI BACCIARDI Distributor: www.techni-lux.com Phone: 407-857-8770 Fax: 407-857-8771 Email: sales@techni-lux.com I GB A000372 rel. 1.00 Via Pio La Torre,

More information

VR8 - VR8R 2000 edition

VR8 - VR8R 2000 edition email: enquiries@sxsevents.co.uk VR8 - VR8R Abstract Design to Light 1998 Tel:0116 278 8078 http://www.abstract-lighting.co.uk VR Instruction Manual - Issue 1.2: May 2000 Written for Abstract Design to

More information

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Gain Electronic Co. Ltd. Table Of Contents Safety Considerations ------------------------------------------------------------2

More information

FOLLOWSPOT CONTROLLER

FOLLOWSPOT CONTROLLER SOFTWARE VERSION 2.0 WWW.PRG.COM FOLLOWSPOT CONTROLLER USER MANUAL AutoPar, Bad Boy, Best Boy, Followspot Controller, Mbox, Mini Node, Nocturne, Series 400, ReNEW, Super Node, V476, V676, and Virtuoso

More information

impact VC-500LR Monolight INSTRUCTIONS

impact VC-500LR Monolight INSTRUCTIONS impact lighting equipment and accessories VC-500LR Monolight INSTRUCTIONS Congratulations on your purchase of the Impact VC-500LR Monolight. We feel that it will contribute much to your photographic skill

More information

Lites PROFILE LED WHITE. Owner s and Service Manual

Lites PROFILE LED WHITE. Owner s and Service Manual Lites PROFILE LED WHITE Owner s and Service Manual Read this manual carefully, and follow all instructions contained herein. File this manual for future reference. It is essential to read and follow guidelines

More information

LS3300 AC Power Calibrator Simple Adjustment Procedure for Voltage, Current, and Frequency

LS3300 AC Power Calibrator Simple Adjustment Procedure for Voltage, Current, and Frequency User s Manual AC Power Calibrator Simple Adjustment Procedure for Voltage, Current, and Frequency The instrument should be adjusted by a qualified engineer at a qualified facility with sufficient precision.

More information

Width (W): 44 mm. bus connecting and branching terminal External supply --- Inputs: Number: up to 2 (depending on parameterization: channel 1 to 2)

Width (W): 44 mm. bus connecting and branching terminal External supply --- Inputs: Number: up to 2 (depending on parameterization: channel 1 to 2) Product name: Design: 2-channel push button interface UP (flush-mounting type) Item no.: 1118 00 ETS search path: Gira Giersiepen / input / binary input, 2fold / Universal push putton interface 2fold Functional

More information

LPTDX CHANNEL DIMMER PACK

LPTDX CHANNEL DIMMER PACK 12-CHANNEL DIMMER PACK 1. Introduction To all residents of the European Union Important environmental information about this product This symbol on the device or the package indicates that disposal of

More information

5 Channel Multifunctional PWM Controller. HomLiCon LCH5T. Technical Specifications

5 Channel Multifunctional PWM Controller. HomLiCon LCH5T. Technical Specifications 5 Channel Multifunctional PWM Controller Application Control of groups LED and LED strips Control of relays, small motors, fans, etc. Control models Technical Specifications Number of Channels 5 Color

More information

This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights

This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights 1- GENERAL DESCRIPTION Electronic for the remote control of tubular motors for roller blinds, rolling shutters, doors with limit switch inside or outside the motor, radio receiver section with transmitter

More information

DMX protocol. Robin LEDdBeam 150/Robin LEDBeam 150 FW - DMX protocol

DMX protocol. Robin LEDdBeam 150/Robin LEDBeam 150 FW - DMX protocol protocol Mode/channel Robin LEDdBeam 150/Robin LEDBeam 150 FW - protocol Version: 1.4 Mode 1-Standard 16-bit, Mode 2 -Reduced 8-bit 1 1 Pan (8 bit) 0-255 Pan movement by 450 (128=default) proportional

More information

Instruction manual. art Installation manual

Instruction manual. art Installation manual Instruction manual art. 01521 Installation manual Contents GENERAL FEATURES AND FUNCTIONALITY from page 4 ETS PARAMETERS AND COMMUNICATION OBJECTS from page 6 COMMUNICATION OBJECTS GENERAL FEATURES AND

More information

WIRELESS DIMMER FOR HEATING

WIRELESS DIMMER FOR HEATING TELECO AUTOMATI SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHE: ++39.0438.388511 FAX: ++39.0438.388536 - www.telecoautomation.com This document is the property of Teleco Automation

More information

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal. , GH Q631 0026 R0111 SK 0097 B97 The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal. The device has 32 freely programmable inputs/outputs,

More information

V~ DIMMER WITH BUILT-IN RADIO RECEIVER AND DALI OUTPUT FOR CONTROL BALLASTS AND LAMPS. Push-button input for manual controls.

V~ DIMMER WITH BUILT-IN RADIO RECEIVER AND DALI OUTPUT FOR CONTROL BALLASTS AND LAMPS. Push-button input for manual controls. MR RESISTOR 110-230V~ DIMMER WITH BUIT-I RADIO RECEIVER AD DAI PUT FOR CTRO BAASTS AD AMPS. Push-button input for manual controls. Product code TVDMA868A01 20 slaves, 868.3Mhz TVDMA868A02 64 slaves, 868.3Mhz

More information

A3 Pro INSTRUCTION MANUAL. Oct 25, 2017 Revision IMPORTANT NOTES

A3 Pro INSTRUCTION MANUAL. Oct 25, 2017 Revision IMPORTANT NOTES A3 Pro INSTRUCTION MANUAL Oct 25, 2017 Revision IMPORTANT NOTES 1. Radio controlled (R/C) models are not toys! The propellers rotate at high speed and pose potential risk. They may cause severe injury

More information

instabus EIB product documentation

instabus EIB product documentation Page: 1 of 39 Push button interface 4-gang Sensor Product name: Push button interface 4-gang Design: UP (flush-mounting type) Item no.: 2076-4T-01 ETS search path: Input / Binary Input, 4-gang / Push button

More information

Motor 1- GENERAL DESCRIPTION

Motor 1- GENERAL DESCRIPTION 1- GENERAL DESCRIPTI TELECO AUTOMATI SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHE: ++39.0438.388511 FAX: ++39.0438.388536 This document is the property of Teleco Automation Srl

More information

Electronic Circuit Breaker BASIC SMART. - Number of available output channels: 2 / 4 / 8

Electronic Circuit Breaker BASIC SMART. - Number of available output channels: 2 / 4 / 8 Electronic Circuit Breaker - Number of available output channels: 2 / 4 / 8 - Adjustable rated current via channel - High capacitive loads start up reliably - The channels switch on sequentially and loaddependent

More information

Channel Remote Programming: For the (35R Motor with or without a Plug) LEFT SIDE AND RIGHT SIDE MOTORS

Channel Remote Programming: For the (35R Motor with or without a Plug) LEFT SIDE AND RIGHT SIDE MOTORS 2016 15 Channel Remote Programming: For the (35R Motor with or without a Plug) LEFT SIDE AND RIGHT SIDE MOTORS Right Side Worms FRONT REMOTE CONTROL BACK Left Side Worms Channel Display Up Stop Down Channel

More information

Lites PROFILE LED WHITE. Owner's and service manual

Lites PROFILE LED WHITE. Owner's and service manual Lites PROFILE LED WHITE Owner's and service manual Read this manual throughout and carefully follow all the instructions contained. File this manual for future perusals It is essential to read and follow

More information

change the existing DMX start channel set preset playback off set preset playback on display which scene is currently playing CLSD close the shutter

change the existing DMX start channel set preset playback off set preset playback on display which scene is currently playing CLSD close the shutter Appendix D Map The Studio Beam fixture s onboard menu system allows you to: Assign a DMX start channel Access fixture options such as, homing the fixture, viewing fixture status, crossloading software,

More information

TM Analogic. Serie TM. Cod. rev

TM Analogic. Serie TM. Cod. rev TM Digital TM Digital-B TM Analogic Serie TM. Cod. rev. 1.0 1 CONTENTS 1 First of all Page 2 2 Installation Page 4 3 Setting and Operation Page 7 4 Maintenance Page 10 1 FIRST OF ALL - WARNINGS Check the

More information

VELA-RX MOTORE 220V 500W

VELA-RX MOTORE 220V 500W VELA-RX MOTORE 220V 500W Electronic control unit with UP, DOWN and STOP functions for managing 230 V, max. 500 W motors via wire and/or radio 1 INDEX 1 - PRODUCT FEATURES 1.1 - TECHNICAL DATA 1.2 - DESCRIPTION

More information

TEAM DIGITAL. Servette TM Single Servo Controller

TEAM DIGITAL. Servette TM Single Servo Controller 12 7 Summary of Configuration Variables CV# Function/Default Value CV# Function/Default Value 1 Servo Address 1 43 reserved - 2 reserved - 44 Sec Input Control 26 3 Servo Move Range 15 45 reserved - 4

More information

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual THE HIGH PERFORMANCE COMPANY Series 70 Hold 1 sec. Hold 1 sec. FOR MORE INFORMATION ON THIS PRODUCT AND OTHER BRAY PRODUCTS PLEASE VISIT OUR WEBSITE www.bray.com Table of Contents 1. Definition of Terms.........................................2

More information

B-Tronic EasyControl EC5401B

B-Tronic EasyControl EC5401B B-Tronic EasyControl EC5401B en Assembly and Operating Instructions Wall/hand-held transmitter, 1-channel, bidirectional Important information for: Fitters / Electricians / Users Please forward accordingly!

More information

PowerBar 4 Manual SAFETY NOTES WARNING! IMPORTANT:

PowerBar 4 Manual SAFETY NOTES WARNING! IMPORTANT: PowerBar 4 Manual Thank you for purchasing this LITECRAFT product. For your own safety, please read the instruction manual carefully before turn on the product for the first time. SAFETY NOTES Each person

More information

Somfy RTS Motor Programming Instructions Motor Programming Instructions have been rewritten by

Somfy RTS Motor Programming Instructions Motor Programming Instructions have been rewritten by Somfy RTS Motor Programming Instructions Motor Programming Instructions have been rewritten by http://www.voutlet.com Please Read and Follow These Instructions. Please use the motor programming instructions

More information

Electronic Circuit Breaker ECONOMY SMART. - Number of available output channels: 2 / 4 / 8

Electronic Circuit Breaker ECONOMY SMART. - Number of available output channels: 2 / 4 / 8 Electronic Circuit Breaker - Number of available output channels: 2 / 4 / 8 - Adjustable rated current for each channel - High capacitive loads start up reliably - The channels switch on sequentially and

More information

Photometric Report. Internet:

Photometric Report.   Internet: Photometric Report e-mail: service@glp.de Internet: http://www.glp.de Impression Spot One Photometric Report Manufacturer: GLP German Light Products GmbH, Im Stöckmädle 13, 76307 Karlsbad, Germany Product:

More information

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor Product description Compact dimensions for luminaire installation For up to 10 DSI or LI devices (max. 5 per output channel)

More information

Electronic Circuit Breaker ECONOMY REMOTE

Electronic Circuit Breaker ECONOMY REMOTE Electronic Circuit Breaker - Number of available output channels: 2 / 4 / 8 - Each channel has a 2-wire interface for adjusting the rated current - High capacitive loads start up reliably - The channels

More information

DMX-CONTROL OF MOTORISED DIMMER SHUTTER AND LAMP IGNITION

DMX-CONTROL OF MOTORISED DIMMER SHUTTER AND LAMP IGNITION RJ NET FOR COMPACT FOLLOWSPOT RANGE Manual 1149B SUPER KORRIGAN 1449B LUCY 1159B VICTOR 1459B FLO DMXCONTROL OF MOTORISED DIMMER SHUTTER AND LAMP IGNITION Product version : "LUCY" 1449 : V3 "SUPER KORRIGAN"

More information

BMFL FollowSpot. Light source 1700 W OSRAM Lok-it! HTI 1700/PS. LIGHT OUTPUT lm, m, m.

BMFL FollowSpot. Light source 1700 W OSRAM Lok-it! HTI 1700/PS. LIGHT OUTPUT lm, m, m. BMFL FollowSpot Created specifically for follow-spot operation, this custom modified version of BMFL comes with specific features to provide both motorised movement and manual operation with follow-spot

More information

Rubix RGB 3D Panel. User Manual. Order code: LEDJ476

Rubix RGB 3D Panel. User Manual. Order code: LEDJ476 Rubix RGB 3D Panel User Manual Order code: LEDJ476 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make

More information

TROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller. Mounting and Operating Instructions EB 5578 EN

TROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller. Mounting and Operating Instructions EB 5578 EN TROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller Mounting and Operating Instructions EB 5578 EN Firmware version 2.2x Edition May 2015 Definition of signal words DANGER!

More information

Programmable Control Introduction

Programmable Control Introduction Programmable Control Introduction By the end of this unit you should be able to: Give examples of where microcontrollers are used Recognise the symbols for different processes in a flowchart Construct

More information

High/Low Bay Passive Infrared Occupancy Sensor

High/Low Bay Passive Infrared Occupancy Sensor Models Sensors: HBP-111-L7, with IR remote capability HBP-112-L7, no IR capability High/Low Bay Passive Infrared Occupancy Sensor Mounting Modules: HBP-EM1 extender module HBP-SM1 surface mount module

More information

DELTA ISSUE 2 HIGH POWER LED PROJECTORS

DELTA ISSUE 2 HIGH POWER LED PROJECTORS DELTA ISSUE 2 HIGH POWER LED PROJECTORS DELTA ISSUE 2 HIGH POWER LED PROJECTORS DELTA ISSUE 2 HIGH POWER LED PROJECTORS P.6 DELTA 10 RGBW F DELTA 10 RGBW F ZOOM P.20 DELTA 8 FULL COLOUR R DELTA 8 FULL

More information

Robin CycFX 8- DMX protocol

Robin CycFX 8- DMX protocol Version 1.4 Robin CycFX 8 Robin CycFX 8- DMX protocol Mode/Channel Value Function Type of control 1 2 3 4 5 6 7 1 1 1 1 1 1 1 Tilt (8 bit) Tilt movement by 270-2 2 2-2 2 Tilt (16 bit) Fine movement of

More information

TROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller. Mounting and Operating Instructions EB 5578 EN

TROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller. Mounting and Operating Instructions EB 5578 EN TROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller Mounting and Operating Instructions EB 5578 EN Firmware version 2.30 Edition November 2017 Definition of signal words DANGER!

More information

AT-SL-DDR & AT-SL-DDR-SA

AT-SL-DDR & AT-SL-DDR-SA AT-SL-DDR & AT-SL-DDR-SA Product Guide Slim-line RF DALI/DSI + relay controller Overview The AT-SL-DDR and AT-SL-DDR-SA are wireless controllers with two output channels capable of controlling incandescent,

More information

HAWK5000 Operators Manual

HAWK5000 Operators Manual HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED

More information

TEAM DIGITAL. SMC4 Servo & Motor Controller

TEAM DIGITAL. SMC4 Servo & Motor Controller 16 CV# Function/Default Value CV# Function/Default Value 28 reserved - 73 Servo 3 Behavior 0 29 Decoder Configuration 0 74 Servo 4 Behavior 0 30 reserved - 75 Output Flash 0 31 Ops Mode Loco Address 1

More information

Ensat driving tools...

Ensat driving tools... nsat driving tools... On this page, you can configure the optimum tool for your application. A configuration is provided in the following as an illustrative example. The article number is composed of two

More information

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL Confirm contents of package: 1 sensor, 1 cable, 1 wide lens (default), 1 narrow lens, mounting template, User s Guide. Install the sensor at the desired

More information

EBA 430 E EBA 430 EP. Operating Instructions

EBA 430 E EBA 430 EP. Operating Instructions EBA 430 E EBA 430 EP Operating Instructions EBA 430 E EBA 430 EP Dear customer, Thank you for choosing a paper cutting machine from EBA. With the purchase of this quality product you can be sure you have

More information

1000TR. Instructions

1000TR. Instructions 1000TR ph Instructions CONTENTS 1. INTRODUCTION... 2 1.1 COMMON INTRODUCTION... 2 1.2 PARTS & ACCESSORIES... 2 2. INSTALLATION... 3 2.1 CASING... 3 2.2 MOUNTING... 3 2.3 ELECTRICAL INSTALLATION... 3 2.3.1

More information

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock MAIN FEATURES: MAIN UNIT GB MODEL: RMR182 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RMR182 Multi- Channel In-Out

More information

AT-SL-ADR & AT-SL-ADR/SA

AT-SL-ADR & AT-SL-ADR/SA AT-SL-ADR & AT-SL-ADR/SA RF 1-10V + relay controller Product Guide Overview The AT-SL-ADR and AT-SL-ADR/SA are wireless controllers with two output channels capable of controlling incandescent, fluorescent

More information

Emotion Luminaire DMX Control Protocol *

Emotion Luminaire DMX Control Protocol * Emotion Luminaire Control Protocol * Standard Prototocol Collage/Keystone Prototocol Channel Construct Channel Construct Pan Coarse Pan Coarse 2 Pan Fine 2 Pan Fine 3 Tilt Coarse 3 Tilt Coarse Tilt Fine

More information

AT-SL-DDR & AT-SL-DDR-SA

AT-SL-DDR & AT-SL-DDR-SA Product Guide AT-SL-DDR & AT-SL-DDR-SA Slim -line RF DALI/DSI + relay controller Overview The AT-SL-DDR andat-sl-ddr-sa are wireless controllers with two output channels capable of controlling incandescent,

More information

Model. Instruction Manual. Digital ph Pen. reedinstruments. REED Instruments

Model. Instruction Manual. Digital ph Pen. reedinstruments. REED Instruments Model Instruction Manual 8689 Digital ph Pen reedinstruments com Table of Contents Features... 3 Specifications... 3 Instrument Description... 4 Operating Instructions...4-10 Data Hold... 5 Auto Power

More information

INDEX 1 - PRODUCT FEATURES

INDEX 1 - PRODUCT FEATURES VELA-RX 220V 1000W Control unit for 1 device with max power 1000W. 110/240 VAC power supply, integrated RX 433.92 MHZ ISM, 2 wired inputs settable with button or switch. Presence simulation function. 1

More information

Fibaro System Modules

Fibaro System Modules Chapter 3 Fibaro System Modules 3.1 Fibaro Dimmer FGD211 Figure 3.1: Dimmer module, FGD-211 Radio controlled light dimming module, designed to work with light sources of any type. May be connected to two-wire

More information

the coemar LED experience

the coemar LED experience the coemar LED experience LED technology has been part of the entertainment lighting industry since the mid-9s. Originally as a simple power on light indicator, LED lights have evolved to become a versatile,

More information

Electronic Circuit Breaker BASIC FIX

Electronic Circuit Breaker BASIC FIX Electronic Circuit Breaker - Number of available output channels: 2 / 4 - Non-adjustable rated current via channel - High capacitive loads start up reliably - The channels switch on sequentially and loaddependent

More information

Medidores de vibración salida RS232 Datalogger VT-8204 LUTRON manual ingles

Medidores de vibración salida RS232 Datalogger VT-8204 LUTRON manual ingles English usermanual VT-8204 Vibration Tachometer Your purchase of this VIBRATION TACHOMETER marks a step forward for you into the field of precision measurement. Although this VIBRATION TACHOMETER is a

More information

Fixture Built-in Sensor Daylight Harvest Version

Fixture Built-in Sensor Daylight Harvest Version Fixture Built-in Sensor Daylight Harvest Version Model: HC419VRC /DH Infrared remote receiver Detection area Hold-time Daylight sensor Buzzer Sensor antenna Photocell Installation hole (4.2mm) 4.2 45 Stand-by

More information

animeo KNX/EIB 4 AC Motor Controller WM/DRM V AC

animeo KNX/EIB 4 AC Motor Controller WM/DRM V AC somfy.com animeo KNX/EIB 4 AC Motor Controller WM/DRM 220-240V AC Installation manual Ref. 1860114 Ref. 1860116 2007, SOMFY SAS. ALL RIGHTS RESERVERD. REF. 5050779-30/04/2007 Table of contents Introduction...

More information

PROFILE 500. Halogen profile-spot

PROFILE 500. Halogen profile-spot PROFILE 500 Halogen profile-spot High definition profile-spot projector Suitable from 2.5mt to 20mt (4 models) Focus and zoom adjustable, slide movement Lamp access at the bottom of projector Steel yoke

More information

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional B-Tronic EasyControl EC5401B en Assembly and Operating Instructions Wall/hand-held transmitter, 1-channel, bidirectional Important information for: Fitters / Electricians / Users Please forward accordingly!

More information

ENGLISH Table of Contents

ENGLISH Table of Contents ENGLISH Table of Contents DGT 3000 Display and buttons... 5 Introduction... 6 Timing methods... 6 Time... 6 Fischer Bonus... 7 US Delay... 7 Delay... 7 Byo-yomi... 7 Canadian Byo-yomi... 8 Upcount... 8

More information

2011 / Circuit Tracer

2011 / Circuit Tracer INSTRUCTION MANUAL 2011 / 00521 Circuit Tracer Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. 52044992 2008 Greenlee Textron

More information

PT 335SCC Multi Operator Manual

PT 335SCC Multi Operator Manual PT 335SCC Multi Operator Manual 755 Griffith Court, Burlington, Ontario, Canada L7L 5R9 Tel:+(905) 633-7663 Fax:+(905) 637-4419 www.graphicwhizard.com 1 TABLE OF CONTENTS Important Information General

More information

Dawson DDM190. Digital Multimeter User s Manual

Dawson DDM190. Digital Multimeter User s Manual Dawson DDM190 Digital Multimeter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories.. Error! Bookmark not defined. Safety Information... 7

More information

DPC-100VO. Proportional Voltage Controller. Features. Applications

DPC-100VO. Proportional Voltage Controller. Features. Applications DPC-100VO Features Main Dec. Microprocessor Controlled Voltage Generator 0-10 V 0-5 V Min. Max. Ground Precision Digital Circuit Replaces Potentiometer Works in 12- or 24-Volt Systems Adjustable Minimum/Maximum

More information

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 Operation and Service Manual Page 2 Manufactured by: LINCAST INTERNATIONAL PTY. LTD. 2/3 Sir Laurence Drive

More information

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space Wireless wall transmitter, 1-gang with inscription space Order No. : 5331.. Wireless wall Order No. : 5333.. Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected

More information

The ideal replacement solution to the VL3000 Series spot or any other 1,000W to 1,500W lamped professional moving spot light.

The ideal replacement solution to the VL3000 Series spot or any other 1,000W to 1,500W lamped professional moving spot light. The ideal replacement solution to the VL3000 Series spot or any other 1,000W to 1,500W lamped professional moving spot light. The Vari-Lite VLZ Profile is a dedicated profile luminaire utilizing the latest

More information

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W L L N N on error RUN 1 2 3 4 KNX EIB 1 1 1 1 Chapter 9: Dimming actuators/control units Chapter 9:Dimming actuators/control unitsart. no.6493xxas of 10/079.2Universal dimming actuators Universal dimming

More information

UR200SI / UR200WE ENGLISH

UR200SI / UR200WE ENGLISH ENGLISH Hersteller Wörlein GmbH Tel.: +49 9103/71670 Gewerbestrasse 12 Fax.: +49 9103/716712 D 90556 Cadolzburg Email. info@woerlein.com GERMANY Web: www.woerlein.com UR200SI / UR200WE ENVIRONMENTAL PROTECTION

More information

Technical Description. DCF77 Receiver-Module 4460

Technical Description. DCF77 Receiver-Module 4460 Technical Description DCF77 Receiver-Module 4460 Version 09.02 23.07.2002 COMPANY INFO Safety information The Safety Instructions and Technical Data serve to ensure trouble-free operation and protection

More information

High Intensity LED Stroboscope Digital Tachometer DT-361/365. Instruction manual. Be sure to read before use.

High Intensity LED Stroboscope Digital Tachometer DT-361/365. Instruction manual. Be sure to read before use. 98585A High Intensity LED Stroboscope Digital Tachometer DT-361/365 Instruction manual Be sure to read before use. Before use, please carefully read these safety precautions as well as instructions, and

More information

KNX manual 1-channel flush-mounted switch actuator SU 1

KNX manual 1-channel flush-mounted switch actuator SU 1 KNX manual 1-channel flush-mounted switch actuator SU 1 4942520 2018-10-04 Contents 1 Function description 3 2 Operation 4 3 Technical data 5 4 The SU 1 application programme 7 4.1 Selection in the product

More information

QL50 Luminescence Sensor

QL50 Luminescence Sensor Compact, self-contained luminescence sensor LISTED US Compact, self-contained design Features Senses luminescent marks, even on luminescent backgrounds and on reflective surfaces, such as ceramic, metal,

More information

The appliance is fitted with a 3-digit display in order to show the room temperature and the 2 + and - key parameters for the programming functions.

The appliance is fitted with a 3-digit display in order to show the room temperature and the 2 + and - key parameters for the programming functions. P.I. Proportional-integral temperature controller with limits function DB-TA-31A WARNINGS Installation and maintenance operations must be carried out by qualified personnel, with the appliance disconnected

More information

AMERITRON SDC-102 Screwdriver Antenna Controller

AMERITRON SDC-102 Screwdriver Antenna Controller AMERITRON SDC-102 Screwdriver Antenna Controller INSTRUCTION MANUAL PLEA S E REA D T H IS M A NU A L BEFORE OP ERA T I N G T H IS EQU IP M EN T! 116 Willow Road Starkville, MS 39759 USA 662-323-8211 Version

More information

Exercise 3-3. Manual Reversing Starters EXERCISE OBJECTIVE DISCUSSION. Build manual reversing starters and understand how they work.

Exercise 3-3. Manual Reversing Starters EXERCISE OBJECTIVE DISCUSSION. Build manual reversing starters and understand how they work. Exercise 3-3 Manual Reversing Starters EXERCISE OBJECTIVE Build manual reversing starters and understand how they work. DISCUSSION Reversing motor rotation direction is a common operation in industrial

More information

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone: 2 3 IMPORTANT SAFETY NOTE: Before operating this device, please read carefully this User Manual and be familiar with its contents prior to using this equipment. To help avoid potential serious injury to

More information

1200 DPS Programmable Digital Powder System

1200 DPS Programmable Digital Powder System 1200 DPS Programmable Digital Powder System WARNINGS AND CAUTIONS: If the 1200 DPS does not read zero on the display, DO NOT DISPENSE POWDER. The scale must be zeroed before use. If powder is dispensed

More information

BFS / BFSM SERIES Installation & Maintenance Manual

BFS / BFSM SERIES Installation & Maintenance Manual Introduction: The BFS / BFSM series electric actuators have battery backup modules for fail safe operation. The BFS series is for two position control and the BFSM series is for proportional control, both

More information