2012 Electric Power Quality and Supply Reliability Conference (PQ 2012) Tartu, Estonia June IEEE Catalog Number: ISBN:
|
|
- Samson Gardner
- 5 years ago
- Views:
Transcription
1 2012 Electric Power Quality and Supply Reliability Conference (PQ 2012) Tartu, Estonia June 2012 IEEE Catalog Number: ISBN: CFP1252E-PRT
2 CONTENTS - Metamodel for Permanent Magnet Synchronous Motor with Outer Rotor J. Dirba., L. Lavrinovicha, G. Jekabsons, S. Vitolina.. 9 Synchronous Generator with Two-channel Excitation for Power Supply of Railway Passenger Cars N. Levin, E. Kamolins, V. Pugachev, A. Gusakov Study and Verification of a Slow Speed PM Generator with Outer Rotor for Small Scale Wind Turbines A. Kilk, O. Kudrjavtsev The Comparison of Active and Reactive Magnetic Couplers B. Ose-Zala, V. Pugachov Testing Results of Slow Speed Electrical Machine, that can Operate as a Synchronous or Double Fed Induction Generator G. Di evs, V. Pugachevs, N. Levins Investigation of Molten Metal Mixing in a DC Electric Arc Furnace with Added AC Component on Different Frequencies H. Mõlder, J. Järvik, T. Vaimann, R. Gordon.. 33 Dual Scheme Based Mathematical Modeling of Magnetically Controlled Shunt Reactors kv B. I. Bazilev, V. Y. Bespalov, S. V. Dyagileva, P. N. Makarov, M. A. Makarova, B. V. Oleksyuk Analysis and Prototyping of a Low-Speed Small Scale Permanent Magnet Generator for Wind Power Applications E. Lepa, A. Kilk Analysis of the Eccentricity in a Low-Speed Slotless Permanent-Magnet Wind Generator A. Kallaste, A. Belahcen, A. Kilk, T. Vaimann Detection of Broken Rotor Bars in Frequency Converter Fed Induction Motor Using Park s Vector Approach T. Vaimann, A. Belachen, J. Martinez, A. Kilk 53 Three-Phase Multilevel Converter Voltage Quality Bounds G. Mehlmann, A. Ruderman, G. Herold Modeling and Classical Control of Unidirectional VIENNA Rectifiers S. Gadelovitz, A. Kuperman Corporate Inspection of Electric Grids 110 kv of Siberia V. Litvak, A. Ivashutenko, E. Bogdanov Power Quality of Supply Characterization in the Portuguese Electricity Transmission Grid A. Tavares, L. C. Pinto /12 $ IEEE 5
3 Contemporary and Future Aspects of Cost Effective Power quality monitoring - Position paper of CIGRE WG C4.112 J. Meyer, J. Kilter, B. Howe, F. Zavoda, L. Tenti, J. M. R. Gordon, J. V. Milanovi Harmonic Analysis with Symmetrical Space Phasor Components S. König, G. Herold Comparison of Wavelet and Fourier analysis in the power quality E. Fuchs, B. Trajanoska, S. Orhouzee, H. Renner. 93 Influences on Safety Issues for Inverter Supplied Grid Structures T. Wieland, M. Aigner, E. Schmautzer, J. Pasker, L. Fickert 101 Electricity Consumption Analysis and Power Quality Monitoring in Commercial Buildings I. Drovtar, J. Niitsoo, A. Rosin, J. Kilter, I. Palu Flicker Source Identification in Meshed High Voltage Grids H. Renner Optimal Selection of Voltage Sag Mitigation Solution Based on Event Tree Method M. Yasir, S. Kazemi, M. Lehtonen, M. Fotuhi-Firuzabad,,, 119 A Novel Approach for Assessing the Impacts of Voltage Sag Events on Customer Operations M. Yasir, S. Kazemi, M. Lehtonen, M. Fotuhi-Firuzabad, Estimation of Small Scale HPP Affect on Distribution Network Reliability under Market Conditions A. Obusev, A. Lvovs, A. Mutule Non-uniformity Impact of Power Losses in Kurzemes Ring Project Case J. Survilo, D. Antonovs, E. Biela Wide-Area Applications for Enhancement of Estonian Power System Security J. Kilter, A. Reinson Supply Voltage Level Optimization in Industrial Low Voltage Networks T. Vinnal, K. Janson, H. Kalda, and T. Sakkos Assessment of Different Power Line Types Life-Time Costs in Distribution Network from Reliability Point of View A. Lvov, I. Priedite-Razgale, J. Rozenkrons, V. Kreslins....., Impact of Distributed Generation Facilities on an Urban Network A. Novitskiy, H. Schau /12 $ IEEE 6
4 Model verification for Analysis of Wind Power Impact to Transient Stability in Isolated Power System Using Combined Relay Protection and Dynamics Modelling Approach R. Maripuu, O. Tsernobrovkin, I. Palu, J. Kilter Wind Power Generation Impact on Sõrve Peninsula Network Operation in Saaremaa V. Bolgov, K. Janson, J. Šklovski, I. Palu, M. Laanetu Middle Voltage Cable Power Lines Relay Protection against Double Ground Faults Influence to Power Supply Reliability J. Rozenkrons, A.Staltmanis Special Features of Transient Processes at Ground Faults in Longdistance Transmission Lines A. Bazavluk, A. Kuzmin, A. Telegin, I. Tsivilyov, A. Panchenko, E. Miksabirov Neutral Point Treatment and Earth Fault Suppression O. Siirto, M. Loukkalahti, M. Hyvärinen, P. Heine, M. Lehtonen Experimental Measuring of the Touch Voltages in Large Compensated Networks P. Toman, D. Topolánek, J. Orságová, J. Dvo ák Development of the Algorithm and Software MVES-TV 2012 for Assessment of Touch Voltage in MV Networks with Compensated Neutral Earthing I. Priedite-Razgale, J. Rozenkrons The Effect of Fault Resistance on the Earth Fault Characteristics on Unearthed and Compensated Neutral Medium Voltage Networks M. F. Abdel-Fattah, M. Lehtonen Transient Processes at Single Phase-to-Ground Faults in Combined Grounded Networks A. Shirkovets, A. Vasilyeva, A. Telegin, L. Sarin Earth Fault Localization with the Help of the Fast-Pulse-Detection-Method using the New High-Power-Current-Injection (HPCI) G. Druml, C. Raunig, P. Schegner, L. Fickert The Self-Extinguishing Current Limit and the Arc-Burning Time of Compensated 20-kV-Power-Grids E. Fuchs, L. Fickert Arc-Quenching Magnetic-Bias-Controlled Reactors with Automatic of Ground Fault Capacitive Current Compensation for 6 to 35 kv Grids A.M. Bryantsev, A.I. Lurie, S. Dyagileva, P. N. Makarov, M. A. Makarova, M.O. Raychenko, A. A. Negryshev, B.V. Oleksyuk..... Integral Arc Models at Single Phase-to-ground Faults and Special Characteristics of Arcing in Power Cable Insulation A. Shirkovets /12 $ IEEE 7
5 Air-core Inductive Current Sensor for Fast Transients Measurements in Distribution Networks L. Kütt, J. Järvik, J. Kilter, M. Shafiq, M. Lehtonen Influence of Rainfall on Lightning Flashovers from Trees to Medium Voltage Bare and Covered Conductors M. A. Omidiora, M. Lehtonen, P. Hyvönen Wet Tests on Naturally Polluted Glass and Composite Insulators P. Taklaja, J. Niitsoo, I. Palu The Investigation of Overvoltage Transient Processes in Railway Electric Power Feeding Systems I. Asmontas, S. Gudzius, L. A. Markevicius, A. Morkvenas, V. Ticka SOC Estimation for Li-Ion Batteries Based on Equivalent Circuit Diagrams and the Application of Kalman Filter A. Rahmoun, H. Biechl, A. Rosin Interaction of Multi-Circuit Overhead Transmission Lines of Different Voltages Located on the Same Pylons A. Novitskiy, D. Westermann Analysis of Electricity Meters under Distorted Load Conditions A. Haas, J. Niitsoo, P. Taklaja, I. Palu Interference of Touch Dimmer Lamps due to PLC and other High Frequency Signals M. Pikkarainen, S. Vehmasvaara, B. A. Siddiqui, P. Pakonen, P. Verho Experiences on Narrowband Power Line Communication of Automated Meter Reading Systems in Finland P. Pakonen, S. Vehmasvaara, M. Pikkarainen, B. A. Siddiqui, P. Verho Analysis of Protection and Control Functions of Low Voltage Part of Substation for Smart Grid Applications M. Mägi. K. Peterson. E. Pettai New optimized analysis method for measuring extended grounding systems M. J. Lindinger, H. Renner, E. Schmautzer New Optimized Analysis Method for Measuring Extended Grounding Systems A. Kazakov, K. Janson, T. Vaimann, J. Järvik Authors Index /12 $ IEEE 8
p. 1 p. 6 p. 22 p. 46 p. 58
Comparing power factor and displacement power factor corrections based on IEEE Std. 18-2002 Harmonic problems produced from the use of adjustable speed drives in industrial plants : case study Theory for
More informationEVALUATION OF DIFFERENT SOLUTIONS OF FAULTED PHASE EARTHING TECHNIQUE FOR AN EARTH FAULT CURRENT LIMITATION
EVALUATION OF DIFFERENT SOLUTIONS OF FAULTED PHASE EARTHING TECHNIQUE FOR AN EARTH FAULT CURRENT LIMITATION David TOPOLANEK Petr TOMAN Michal PTACEK Jaromir DVORAK Brno University of Technology - Czech
More informationAmir Farughian
Uudet tekniikat sähköverkon vikatilanteiden ja hajautetun tuotannon hallinnassa Amir Farughian Overview Single-phase earth fault location Review of the existing methods Improving a method Sequence currents
More informationScienceDirect. Simulation Models for Various Neutral Earthing Methods in Medium Voltage Systems
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 1 (15 ) 118 1191 5th DAAAM International Symposium on Intelligent Manufacturing and Automation, DAAAM 1 Simulation Models for
More informationPotential Impacts of khz Harmonic Emissions on Smart Grid Communications in the United States
Potential Impacts of 9-150 khz Harmonic Emissions on Smart Grid Communications in the United States Maria Arechavaleta, S. Mark Halpin, Adam Birchfield, Wendy Pittman, W. Eric Griffin, Michael Mitchell
More informationExperimental Investigations and Calculations in 6-35 kv Networks with Various Neutral Conditions
PQ20 June 16-18, 2010 Kuressaare Experimental Investigations and Calculations in 6-35 kv Networks with Various Neutral Conditions A. Shirkovets, A. Vasilyeva, A. Telegin LLC BOLID, Novosibirsk, Russia
More informationEH2741 Communication and Control in Electric Power Systems Lecture 2
KTH ROYAL INSTITUTE OF TECHNOLOGY EH2741 Communication and Control in Electric Power Systems Lecture 2 Lars Nordström larsno@kth.se Course map Outline Transmission Grids vs Distribution grids Primary Equipment
More informationPOWER ISIPO 29 ISIPO 27
SI NO. TOPICS FIELD ISIPO 01 A Low-Cost Digital Control Scheme for Brushless DC Motor Drives in Domestic Applications ISIPO 02 A Three-Level Full-Bridge Zero-Voltage Zero-Current Switching With a Simplified
More informationHigh Voltage DC Transmission 2
High Voltage DC Transmission 2 1.0 Introduction Interconnecting HVDC within an AC system requires conversion from AC to DC and inversion from DC to AC. We refer to the circuits which provide conversion
More informationHarmonic Distortion Levels Measured at The Enmax Substations
Harmonic Distortion Levels Measured at The Enmax Substations This report documents the findings on the harmonic voltage and current levels at ENMAX Power Corporation (EPC) substations. ENMAX is concerned
More informationB.Tech Academic Projects EEE (Simulation)
B.Tech Academic Projects EEE (Simulation) Head office: 2 nd floor, Solitaire plaza, beside Image Hospital, Ameerpet Ameerpet : 040-44433434, email id : info@kresttechnology.com Dilsukhnagar : 9000404181,
More informationSAFETY ASPECTS AND NOVEL TECHNICAL SOLUTIONS FOR EARTH FAULT MANAGEMENT IN MV ELECTRICITY DISTRIBUTION NETWORKS
SAFETY ASPECTS AND NOVEL TECHNICAL SOLUTIONS FOR EARTH FAULT MANAGEMENT IN MV ELECTRICITY DISTRIBUTION NETWORKS A. Nikander*, P. Järventausta* *Tampere University of Technology, Finland, ari.nikander@tut.fi,
More informationPower Quality Compensation by using UPFC
ISSN: 2454-132X Impact factor: 4.295 (Volume 4, Issue 2) Available online at: www.ijariit.com Power Quality Compensation by using UPFC P. Madhumathi madhumathi9196@gmail.com Vivekanada College of Engineering
More informationIndustrial Electrician Level 3
Industrial Electrician Level 3 Industrial Electrician Unit: C1 Industrial Electrical Code I Level: Three Duration: 77 hours Theory: Practical: 77 hours 0 hours Overview: This unit is designed to provide
More informationElectrical Power Systems
Electrical Power Systems CONCEPT, THEORY AND PRACTICE SECOND EDITION SUBIR RAY Professor MVJ College of Engineering Bangalore PHI Learning Pfcte tofm Delhi-110092 2014 Preface xv Preface to the First Edition
More informationP2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company
P2 Power Solutions Pvt. Ltd. An ISO 9001:2008 Company Quality Power within your Reach P2 Power Magnetics P2 Power Solutions Pvt. Ltd. P2 Power Solutions Pvt. Ltd. provides EMC and power quality solutions,
More informationCONTENTS. 1. Introduction Generating Stations 9 40
CONTENTS 1. Introduction 1 8 Importance of Electrical Energy Generation of Electrical Energy Sources of Energy Comparison of Energy Sources Units of Energy Relationship among Energy Units Efficiency Calorific
More informationUProtection Requirements. Ufor a Large scale Wind Park. Shyam Musunuri Siemens Energy
UProtection Requirements Ufor a Large scale Wind Park Shyam Musunuri Siemens Energy Abstract: In the past wind power plants typically had a small power rating when compared to the strength of the connected
More informationIntroduce system protection relays like underfrequency relays, rate of change of frequency relays, reverse - power flow
Module 1 : Fundamentals of Power System Protection Lecture 3 : Protection Paradigms - System Protection Objectives In this lecture we will: Overview dynamics in power systems. Introduce system protection
More informationELECTRICAL POWER ENGINEERING
Introduction This trainer has been designed to provide students with a fully comprehensive knowledge in Electrical Power Engineering systems. The trainer is composed of a set of modules for the simulation
More informationEducation & Training
Distribution System Operator Certificate This program provides you with a proficient working knowledge in modern electric power distribution systems. These four classes are designed to walk students through
More informationth International Conference on Harmonics and Quality of Power
2014 16th International Conference on Harmonics and Quality of Power (ICHQP 2014) Bucharest, Romania 25 28 May 2014 IEEE Catalog : ISBN: CFP14CHP-POD 978-1-4673-6485-0 #59 #73 #74 #65 #57 #218 #92 #193
More informationFGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI
FGJTFWP"KPUKWG"QH"GEJPQNQI[" FGRTOGP"QH"GNGETKEN"GPIKPGGTKPI" GG"46"JKIJ"XQNIG"GPIKPGGTKPI Resonant Transformers: The fig. (b) shows the equivalent circuit of a high voltage testing transformer (shown
More informationMODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER
MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER Akash A. Chandekar 1, R.K.Dhatrak 2 Dr.Z.J..Khan 3 M.Tech Student, Department of
More informationSummary of the Impacts of Grounding on System Protection
Summary of the Impacts of Grounding on System Protection Grounding System grounding big impact on ability to detect ground faults Common ground options:» Isolated ground (ungrounded)» High impedance ground»
More informationINTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY
INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY A PATH FOR HORIZING YOUR INNOVATIVE WORK SPECIAL ISSUE FOR NATIONAL LEVEL CONFERENCE "Technology Enabling Modernization
More informationCourse No: 1 13 (3 Days) FAULT CURRENT CALCULATION & RELAY SETTING & RELAY CO-ORDINATION. Course Content
Course No: 1 13 (3 Days) FAULT CURRENT CALCULATION & RELAY SETTING & RELAY CO-ORDINATION Sr. No. Course Content 1.0 Fault Current Calculations 1.1 Introduction to per unit and percentage impedance 1.2
More informationAnalysis of Harmonic Distortion in Non-linear Loads
Analysis of Harmonic Distortion in Non-linear Loads Anne Ko Department of Electrical Power Engineering Mandalay Technological University, Mandalay, Myanmar.Phone:+95-09-2225761 anneko101082@gmail.com Wunna
More informationPower Quality enhancement of a distribution line with DSTATCOM
ower Quality enhancement of a distribution line with DSTATCOM Divya arashar 1 Department of Electrical Engineering BSACET Mathura INDIA Aseem Chandel 2 SMIEEE,Deepak arashar 3 Department of Electrical
More informationCONVERTERS IN POWER VOLTAGE-SOURCED SYSTEMS. Modeling, Control, and Applications IEEE UNIVERSITATSBIBLIOTHEK HANNOVER. Amirnaser Yazdani.
VOLTAGE-SOURCED CONVERTERS IN POWER SYSTEMS Modeling, Control, and Applications Amirnaser Yazdani University of Western Ontario Reza Iravani University of Toronto r TECHNISCHE INFORMATIONSBIBLIOTHEK UNIVERSITATSBIBLIOTHEK
More informationPQ for Industrial Benchmarking with various methods to improve. Tushar Mogre.
General PQ: Power Quality has multiple issues involved. Thus, need to have some benchmarking standards. Very little is spoken about the LT supply installation within an industry. There is need to understand
More informationISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements
Division 502 Technical Applicability 1(1) Section 502.1 applies to: Expedited Filing Draft August 22, 2017 the legal owner of an aggregated generating facility directly connected to the transmission system
More informationPower Quality Analysis in Power System with Non Linear Load
International Journal of Electrical Engineering. ISSN 0974-2158 Volume 10, Number 1 (2017), pp. 33-45 International Research Publication House http://www.irphouse.com Power Quality Analysis in Power System
More informationAcknowledgements Introduction p. 1 Electric Power Quality p. 3 Impacts of Power Quality Problems on End Users p. 4 Power Quality Standards p.
Preface p. xv Acknowledgements p. xix Introduction p. 1 Electric Power Quality p. 3 Impacts of Power Quality Problems on End Users p. 4 Power Quality Standards p. 6 Power Quality Monitoring p. 7 Power
More informationHIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24
LECTURER-24 GENERATION OF HIGH ALTERNATING VOLTAGES When test voltage requirements are less than about 300kV, a single transformer can be used for test purposes. The impedance of the transformer should
More informationNumbering System for Protective Devices, Control and Indication Devices for Power Systems
Appendix C Numbering System for Protective Devices, Control and Indication Devices for Power Systems C.1 APPLICATION OF PROTECTIVE RELAYS, CONTROL AND ALARM DEVICES FOR POWER SYSTEM CIRCUITS The requirements
More informationPower Systems Modelling and Fault Analysis
Power Systems Modelling and Fault Analysis Theory and Practice Nasser D. Tleis BSc, MSc, PhD, CEng, FIEE AMSTERDAM BOSTON HEIDELBERG LONDON NEW YORK OXFORD PARIS SAN DIEGO SAN FRANCISCO SINGAPORE SYDNEY
More informationModeling of Statcom. P.M. Sarma and Dr. S.V. Jaya Ram Kumar. Department of Electrical & Electronics Engineering GRIET, Hyderabad, India
International Journal of Electrical Engineering. ISSN 974-2158 Volume 6, Number 1 (213), pp. 69-76 International Research Publication House http://www.irphouse.com Modeling of Statcom P.M. Sarma and Dr.
More informationELEMENTS OF FACTS CONTROLLERS
1 ELEMENTS OF FACTS CONTROLLERS Rajiv K. Varma Associate Professor Hydro One Chair in Power Systems Engineering University of Western Ontario London, ON, CANADA rkvarma@uwo.ca POWER SYSTEMS - Where are
More informationProtection of Electrical Networks. Christophe Prévé
Protection of Electrical Networks Christophe Prévé This Page Intentionally Left Blank Protection of Electrical Networks This Page Intentionally Left Blank Protection of Electrical Networks Christophe Prévé
More informationth International Conference on Harmonics and Quality of Power (ICHQP 2016)
2016 17th International Conference on Harmonics and Quality of Power (ICHQP 2016) Belo Horizonte, Brazil 16-19 October 2016 s 1-512 IEEE Catalog : ISBN: CFP16CHP-POD 978-1-5090-3793-3 1/2 Copyright 2016
More informationFundamental Concepts of Dynamic Reactive Compensation. Outline
1 Fundamental Concepts of Dynamic Reactive Compensation and HVDC Transmission Brian K. Johnson University of Idaho b.k.johnson@ieee.org 2 Outline Objectives for this panel session Introduce Basic Concepts
More informationMonitoring Locations in Smart Grids 14PESGM2391
1 Panel Session PQ Monitoring in the Era of Smart Grids Monitoring Locations in Smart Grids 14PESGM2391 Francisc Zavoda IREQ (HQ) QUÉBEC, CANADA Power System and Monitoring Locations 2 Power System Classic
More informationAdaptive ANN based STATCOM and DVR for optimal integration of wind energy with grid using permanent magnet synchronous generator
Adaptive ANN based STATCOM and DVR for optimal integration of wind energy with grid using permanent magnet synchronous generator Priyanka Sahu Columbia Institute of Engineering and Technology, Raipur,
More informationChhattisgarh Swami Vivekanand Technical University, Bhilai
Scheme of teaching and examination M.E.(POWER ELECTRONICS) in the Department of Electrical Engg. IIIrd SEMESTER S N Board of study Subject code 1 Electrical Engg. 562311(24) Subject Name Static VAR Controller
More informationPOWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.
POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS. This document may be subject to changes. Contact ARTECHE to confirm the characteristics and availability of the products
More informationBhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)
ISSN: 2349-7637 (Online) RESEARCH HUB International Multidisciplinary Research Journal (RHIMRJ) Research Paper Available online at: www.rhimrj.com Modeling and Simulation of Distribution STATCOM Bhavin
More informationThyristorised Automatic Power Factor
Thyristorised Automatic Power Factor Correction with 7% D Tune Harmonics Suppression (Reactor/Filtering) System Power quality? In the present Low voltage (LV) industrial distribution system the power factor
More informationInternational Journal of Advance Engineering and Research Development
Scientific Journal of Impact Factor (SJIF): 3.134 International Journal of Advance Engineering and Research Development Volume 3, Issue 1, January -2016 e-issn (O): 2348-4470 p-issn (P): 2348-6406 Design
More informationEnhancement of Fault Current and Overvoltage by Active Type superconducting fault current limiter (SFCL) in Renewable Distributed Generation (DG)
Enhancement of Fault Current and Overvoltage by Active Type superconducting fault current limiter (SFCL) in Renewable Distributed Generation (DG) PATTI.RANADHEER Assistant Professor, E.E.E., PACE Institute
More informationSolutions for Governance and Suppression of Power Harmonic in Cities
Solutions for Governance and Suppression of Power Harmonic in Cities Li Xiangchu Hunan Nonferrous Metals Vocational and Technical College Zhuzhou, Hunan, 412006, China e-mail: hnysjxjwk@126.com Zhang wei
More informationSingle Phase Earth Fault Location in the Medium Voltage Distribution Networks
1.2478/v1144-9-2-6 SCINTIFIC PROCDINGS OF RIG TCHNICL UNIVRSITY TH 5TH INTRNTIONL SCINTIFIC CONFRNC POWR ND LCTRICL NGINRING, OCTOBR 29 Single Phase arth Fault Location in the Medium Voltage Distribution
More informationReview on Shunt Active Power Filter for Three Phase Four Wire System
2014 IJEDR Volume 2, Issue 1 ISSN: 2321-9939 Review on Shunt Active Power Filter for Three Phase Four Wire System 1 J. M. Dadawala, 2 S. N. Shivani, 3 P. L. Kamani 1 Post-Graduate Student (M.E. Power System),
More informationPower Quality Solutions PQSine P-Series of Active Harmonic Filters and Power Optimizers
EPCOS Product Brief 2017 Power Quality Solutions of Active Harmonic Filters and Power Optimizers EPCOS has been offering a comprehensive range of key components for power factor correction (PFC) and power
More informationDigital Fault Recorder Deployment at HVDC Converter Stations
Digital Fault Recorder Deployment at HVDC Converter Stations On line continuous monitoring at HVDC Converter Stations is an important asset in determining overall system performance and an essential diagnostic
More informationStudy on Reactive Automatic Compensation System Design
Available online at www.sciencedirect.com Physics Procedia 24 (2012) 211 216 2012 International Conference on Applied Physics and Industrial Engineering Study on Reactive Automatic Compensation System
More informationEnhancement of Voltage Stability & reactive Power Control of Distribution System Using Facts Devices
Enhancement of Voltage Stability & reactive Power Control of Distribution System Using Facts Devices Aarti Rai Electrical & Electronics Engineering, Chhattisgarh Swami Vivekananda Technical University,
More informationAn Introduction to Power Quality
1 An Introduction to Power Quality Moderator n Ron Spataro AVO Training Institute Marketing Manager 2 Q&A n Send us your questions and comments during the presentation 3 Today s Presenter n Andy Sagl Megger
More informationCascaded Two Level Electrical Converter-Based Multilevel STATCOM for High Power Utilization
Cascaded Two Level Electrical Converter-Based Multilevel STATCOM for High Power Utilization D.Nagaraju M.Tech-PE, Vidya Bharathi Institute of Technology, T.S, India. L.Ramesh Associate Professor, Vidya
More informationVolume I Issue VI 2012 September-2012 ISSN
A 24-pulse STATCOM Simulation model to improve voltage sag due to starting of 1 HP Induction-Motor Mr. Ajay Kumar Bansal 1 Mr. Govind Lal Suthar 2 Mr. Rohan Sharma 3 1 Associate Professor, Department of
More informationCoupling modes. Véronique Beauvois, Ir Copyright 2015 Véronique Beauvois, ULg
Coupling modes Véronique Beauvois, Ir. 2015-2016 General problem in EMC = a trilogy Parameters Amplitude Spectrum Source (disturbing) propagation Coupling modes Victim (disturbed) lightning electrostatic
More informationOVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT
OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT Harshkumar Sharma 1, Gajendra Patel 2 1 PG Scholar, Electrical Department, SPCE, Visnagar, Gujarat, India 2 Assistant
More informationMODIFICATION OF THE ARRESTER ARRANGEMENT WHEN CONVERTING THE METHOD OF NEUTRAL TREATMENT
MODIFICATION OF THE ARRESTER ARRANGEMENT WHEN CONVERTING THE METHOD OF NEUTRAL TREATMENT Claus NEUMANN Darmstadt University of Technology Germany claus.neumann@amprion.net Klaus WINTER Swedish Neutral
More informationDETECTION AND CLASSIFICATION OF POWER QUALITY DISTURBANCES
DETECTION AND CLASSIFICATION OF POWER QUALITY DISTURBANCES Ph.D. THESIS by UTKARSH SINGH INDIAN INSTITUTE OF TECHNOLOGY ROORKEE ROORKEE-247 667 (INDIA) OCTOBER, 2017 DETECTION AND CLASSIFICATION OF POWER
More informationIndex. b back-flashover 245 biomass 207 breakers 74 buchholz protection 235 busbar sectionalizer 193 business enterprises 18
331 Index a activity plan 318 agricultural enterprise 21 annual increase factor 12 annuity factor 44, 156 annuity method 38 ANSI code numbers 237 arrester, protection level 245 assessment of losses 38
More informationSubject-wise Tests Tests will be activated at 06:00 pm on scheduled day
Subject Name EE-01 Control Systems EE-02 Systems and Signal Processing EE-03 Analog and Digital Electronics EE-04 Engineering Mathematics and Numerical Analysis EE-05 Electric Circuits and Fields EE-06
More information[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785
IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY POWER QUALITY IMPROVEMENT OF GRID CONNECTED WIND ENERGY SYSTEM BY USING STATCOM Mr.Mukund S. Mahagaonkar*, Prof.D.S.Chavan * M.Tech
More informationISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements
Applicability 1(1) Section 502.1 applies to the ISO, and subject to the provisions of subsections 1(2), (3) and (4) to any: (a) a new wind aggregated generating facility to be connected to the transmission
More informationGrid Interconnection of Wind Energy System at Distribution Level Using Intelligence Controller
Energy and Power Engineering, 2013, 5, 382-386 doi:10.4236/epe.2013.54b074 Published Online July 2013 (http://www.scirp.org/journal/epe) Grid Interconnection of Wind Energy System at Distribution Level
More informationNew Methods to Mitigate Distribution System Harmonics
Alberta Power Industry Consortium 214 Power & Energy Innovation Forum New Methods to Mitigate Distribution System Harmonics By Wilsun Xu Power Disturbance & Signaling Research Lab November 5, 214 Outline
More informationStatic Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load 1
Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load MADHYAMA V. WANKHEDE Department Of Electrical Engineering G. H. Raisoni College of
More informationWILEY CONTROL OF POWER INVERTERS IN RENEWABLE ENERGY AND SMART GRID INTEGRATION. Qing-Chang Zhong. Tomas Hornik IEEE PRESS
CONTROL OF POWER INVERTERS IN RENEWABLE ENERGY AND SMART GRID INTEGRATION Qing-Chang Zhong The University of Sheffield, UK Tomas Hornik Turbo Power Systems Ltd., UK WILEY A John Wiley & Sons, Ltd., Publication
More informationIntroduction to Harmonics and Power Quality
NWEMS Introduction to Harmonics and Power Quality August 20 24, 2018 Seattle, WA Track B Anaisha Jaykumar (SEL) Class Content» Definition of power quality (PQ)» Impact of PQ problems» Sources of poor PQ»
More informationPowerMonitor 5000 Family Advanced Metering Functionality
PowerMonitor 5000 Family Advanced Metering Functionality Steve Lombardi, Rockwell Automation The PowerMonitor 5000 is the new generation of high-end electrical power metering products from Rockwell Automation.
More informationVoltage Sag and Swell Mitigation Using Dynamic Voltage Restore (DVR)
Voltage Sag and Swell Mitigation Using Dynamic Voltage Restore (DVR) Mr. A. S. Patil Mr. S. K. Patil Department of Electrical Engg. Department of Electrical Engg. I. C. R. E. Gargoti I. C. R. E. Gargoti
More informationUtility Interconnection and System Protection
Utility Interconnection and System Protection Alex Steselboim President, Advanced Power Technologies, Inc. Utility paralleling vs. isolated operation. Isochronous kw load sharing Reactive power (VAR) sharing
More information1. Introduction to Power Quality
1.1. Define the term Quality A Standard IEEE1100 defines power quality (PQ) as the concept of powering and grounding sensitive electronic equipment in a manner suitable for the equipment. A simpler and
More informationA Control Scheme Research Based on Sliding Mode and Proportional-Integral Control for Three-phase Rectifier
This article has been accepted and published on J-STAGE in advance of copyediting. Content is final as presented. A Control Scheme Research Based on Sliding Mode and Proportional-Integral Control for Three-phase
More informationSRI VIDYA COLLEGE OF ENGG AND TECH
EEE6603 PSOC Page 1 UNIT-III REACTIVE POWER VOLTAGE CONTROL 1. List the various components of AVR loop? The components of automatic voltage regulator loop are exciter, comparator, amplifier, rectifier
More informationExcitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation
Excitation Systems Compound-Excitation System for Synchronous Generators Power Generation Operating Characteristics Load dependent Short circuit supporting Low voltage gradient dv/dt Black start capability
More informationProblems connected with Commissioning of Power Transformers
Problems connected with Commissioning of Power Transformers ABSTRACT P Ramachandran ABB India Ltd, Vadodara, India While commissioning large Power Transformers, certain abnormal phenomena were noticed.
More informationVSC Transmission. Presentation Overview. CIGRE B4 HVDC and Power Electronics HVDC Colloquium, Oslo, April LCC HVDC Transmission
CIGRE B4 HVDC and Power Electronics HVDC Colloquium, Oslo, April 2006 VSC Transmission presented by Dr Bjarne R Andersen, Andersen Power Electronic Solutions Ltd Presentation Overview - Basic Characteristics
More informationThis webinar brought to you by The Relion Product Family Next Generation Protection and Control IEDs from ABB
This webinar brought to you by The Relion Product Family Next Generation Protection and Control IEDs from ABB Relion. Thinking beyond the box. Designed to seamlessly consolidate functions, Relion relays
More informationPower Quality Analysers
Power Quality Analysers Review of Power Quality Indicators and Introduction to Power Analysers ZEDFLO Australia 6-Mar-2011 www.zedflo.com.au Power Quality Indicators Review of main indicators of electrical
More informationA New Technology. for Measuring Overhead Line and Cable Impedance Values and the Ground Impedance of Large Substations. Feature
Feature A New Technology for Measuring Overhead Line and Cable Impedance Values and the Ground Impedance of Large Substations Introduction The knowledge of overhead line and cable impedances is very important
More informationEH27401 Communication and Control in Electric Power Systems Lecture 2. Lars Nordström
EH27401 Communication and Control in Electric Power Systems Lecture 2 Lars Nordström larsn@ics.kth.se 1 Course map 2 Outline 1. Power System Topologies Transmission Grids vs Distribution grids Radial grids
More informationMultilevel Inverter Based Statcom For Power System Load Balancing System
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE) e-issn: 2278-2834,p- ISSN: 2278-8735 PP 36-43 www.iosrjournals.org Multilevel Inverter Based Statcom For Power System Load Balancing
More informationChapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two
Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL Basically the HVDC transmission consists in the basic case of two convertor stations which are connected to each other by a transmission link consisting of an overhead
More informationPower Quality Improvement of Grid Connected Wind Energy System by Statcom for Balanced and Unbalanced Linear and Nonlinear Loads
International Journal of Engineering Research and Development e-issn: 2278-67X, p-issn: 2278-8X, www.ijerd.com Volume 3, Issue 1 (August 212), PP. 9-17 Power Quality Improvement of Grid Connected Wind
More informationHARMONICS CAUSES AND EFFECTS
HARMONICS CAUSES AND EFFECTS What is Harmonics? Harmonics is defined as the content of the signal whose frequency is an integral multiple of the system frequency of the fundamentals. Harmonics current
More informationCHAPTER 6 ANALYSIS OF THREE PHASE HYBRID SCHEME WITH VIENNA RECTIFIER USING PV ARRAY AND WIND DRIVEN INDUCTION GENERATORS
73 CHAPTER 6 ANALYSIS OF THREE PHASE HYBRID SCHEME WITH VIENNA RECTIFIER USING PV ARRAY AND WIND DRIVEN INDUCTION GENERATORS 6.1 INTRODUCTION Hybrid distributed generators are gaining prominence over the
More informationModern Concepts of Energy Control Technology through VVVF Propulsion Drive
Modern Concepts of Energy Control Technology through VVVF Propulsion Drive Satoru OZAKI, Fuji Electric Systems Co., Ltd. Ken-ichi URUGA, Toyo Denki Seizo K.K. Dr. D.P. Bhatt, Autometers Alliance Ltd ABSTRACT
More informationDESIGN AND ANALYSIS OF ELIMINATION OF HARMONICS USING WIND ENERGY CONVERSION SYSTEMS
DESIGN AND ANALYSIS OF ELIMINATION OF HARMONICS USING WIND ENERGY CONVERSION SYSTEMS Dr.S.K.PURUSHOTHAMAN Associate Professor Department of EEE Sri Venkateswara College Of Engineering And Technology, Thirupachur
More informationEE171. H.H. Sheikh Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E
EE171 Electrical Equipment & Control System: Electrical Maintenance Transformers, Motors, Variable Speed Drives, Generators, Circuit Breakers, Switchgears & Protective Systems H.H. Sheikh Sultan Tower
More informationThree Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology
Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology Riya Philip 1, Reshmi V 2 Department of Electrical and Electronics, Amal Jyothi College of Engineering, Koovapally, India 1,
More informationHarmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017
Harmonics and Their Impact on Power Quality Wayne Walcott Application Engineering Manager June, 2017 Presentation Overview A little about harmonics What are harmonics What are NOT harmonics What creates
More informationImprovement of Electricity Distribution Services Using a DVR with a Constant DC Voltage Source Instaled in MV Connection Substations
Improvement of Electricity Distribution Services Using a DVR with a Constant DC Voltage Source Instaled in MV Connection Substations Gheorghe Ioan Nicolaescu, Horia Andrei, Stefan Radulescu Electrical
More informationEXCITATION SYSTEM MODELS OF GENERATORS OF BALTI AND EESTI POWER PLANTS
Oil Shale, 2007, Vol. 24, No. 2 Special ISSN 0208-189X pp. 285 295 2007 Estonian Academy Publishers EXCITATION SYSTEM MODELS OF GENERATORS OF BALTI AND EESTI POWER PLANTS R. ATTIKAS *, H.TAMMOJA Department
More informationHigh voltage engineering
High voltage engineering Overvoltages power frequency switching surges lightning surges Overvoltage protection earth wires spark gaps surge arresters Insulation coordination Overvoltages power frequency
More informationLiterature Review for Shunt Active Power Filters
Chapter 2 Literature Review for Shunt Active Power Filters In this chapter, the in depth and extensive literature review of all the aspects related to current error space phasor based hysteresis controller
More information