Integra and Paladin Transducers
|
|
- Myles Sutton
- 5 years ago
- Views:
Transcription
1 Integra and Paladin Transducers Integra multi function transducers provide high accuracy <0.2% measurements and communicate up to 50 major electrical and power quality parameters, including true RMS system values, power quality data and total harmonic distortion (THD) measurement up to the 31st harmonic. Transducers meet high technical specifications and incorporate pulsed, analogue and digital communication outputs. Operation The multi function Integra 1560 transducer offers uncomplicated operation and high accuracy <0.2% measurement of three-phase voltage, current, frequency, watts, VAr, VA, energy, power factor and total harmonic distortion measurement of both phase and system, current and voltage. A simple Windows TM based software package is provided to configure the transducer. Once configured, up to 50 electrical and power quality variables can be simultaneously input into building management systems via pulsed, analogue or digital communication options. Status may also be monitored via a PC through a software package. Measurement and Communication Up to 50 electrical and power quality parameters can be measured and input into building management systems or viewed through the software configuration package via a PC. Volts L1-N, L2-N, L3-N Volts L1-L2, L2-L3, L3-L1 System volts L-N (average) System volts L-L (average) Current line 1, 2 and 3 System current (average) Current sum Current demand Current maximum demand Neutral current System frequency Watts 1, 2 and 3 System watts (sum) Watts demand (import) Watts maximum demand (import) Watt-hours (import) VAr 1, 2 and 3 System VAr (sum) VAr-hours (import) VA 1, 2 and 3 System VA (sum) Power factor 1, 2 and 3 System power factor (average) Phase angle 1, 2 and 3 System phase angle (average) THD volts 1, 2 and 3 THD system volts (mean) THD amps 1, 2 and 3 THD system amps (mean) Alternatively, an optional menu driven display unit can be used to configure and monitor up to 32 measured parameters including three-phase voltage and current and system watts, VAr, VA, power factor, energy and total harmonic distortion. The Integra Display unit panel can be permanently mounted next to the transducer or simply connected at times when configuration, adjustment and/or status information is required. Accuracy Integra transducers utilize true RMS measurement techniques up to the 31st harmonic, providing <0.2% accuracy. An exceptional tolerance to high harmonic frequencies is achieved from the robust frequency detection method, which is able to lock the fundamental frequency onto any phase. High integrity measurements are possible where the system approximates CT current in the absence of voltage signals. Dimensions Integra 1560 DIN-rail Mounted Transducer 12
2 Ordering Codes Three-phase three-wire unbalanced load INT-1561-*-5-**-option-*** Integra phase 5A CT input, DIN rail C INT-1562-*-5-**-option-*** Integra phase 3-wire 5A CT input, DIN rail C INT-1563-*-5-**-option-*** Integra phase 3-wire 5A CT input, DIN rail C INT-1564-*-5-**-option-*** Integra phase 4-wire 5A CT input, DIN rail C INT-1581-*-5-**-option-*** Integra phase 5A CT input, base mount C INT-1582-*-5-**-option-*** Integra phase 3-wire 5A CT input, base mount C INT-1583-*-5-**-option-*** Integra phase 3-wire 5A CT input, base mount C INT-1584-*-5-**-option-*** Integra phase 4-wire 5A CT input, base mount C * voltage suffix L V L-N 1561 and 1581 C V L-L ( V L-N) 1562 and V L-L ( V L-N) 1563,4 and 1583,4 M V L-N 1561 and 1581 C V L-L ( V L-N) 1562 and V L-L ( V L-N) 1563,4 and 1583,4 **Auxiliary supply suffix C L 12 48V dc C M V ac/dc C Communications Pulsed/relay outputs RS485 interface Modbus TM or Johnson Controls Metasys NII C C C C C C C C C C C C C C C C C C C C C C C C ***Analogue output range 0 No output C ma, 10V compliance (user configurable as C 4-20 ma) 3-1/0/+1 ma, 10V compliance C Profibus TM Lonworks TM interface Analogue outputs Three-phase four-wire unbalanced load Lonworks TM, Modbus TM are trademarks 13
3 Paladin Transducers 250 Series An extensive range of Class 0.5 transducers providing measurement, isolation and conversion of electrical parameters into industry standard dc output signals. The range offers protection against high voltage and overload and resistance to vibration in harsh electrical environments. Transducers offer multiple analogue outputs in a single housing and individual measurement of most electrical parameters. AC Current Average Sensing 1-phase 5A-0/20mA 5A CT 253-TAAW-LSHF-C5 C input. Self powered 1-phase 5A-4/20mA 5A CT 253-TALW-LSHG-C5-AM C input. aux 230V/50Hz 1-phase 5A4/20mA 5A CT 253-TALW-LSHG-C5-AV C input. aux 400V/50Hz AC Voltage Average Sensing 1-phase 230V-0/20mA 253-TVAW-RQHF-C5 C 1-phase 400V-0/20mA 253-TVAW-SCHF-C5 C 1-phase 230V-4/20mA 253-TVLW-RQHG-C5-AM C aux 230V/50Hz 1-phase 230V-4/20mA 253-TVLW-RQHG-C5-AV C aux 400V/50Hz 1-phase 400V- 4/20mA 253-TVLW-SCHG-C5-AM C aux 230V/50Hz 1-phase 400V-4/20mA 253-TVLW-SCHG-C5-AV C aux 400V/50Hz Frequency Transducer 230V-0/20mA 45/55Hz 253-THZW-RQHF-AG C 230V-4/20mA 45/55Hz 253-THZW-RQHG-AG C Watts Power Transducers 3-phase 3-wire balanced load 256-TWLW-QZFA-C5-VN C 3-phase 3-wire balanced load 256-TWLW-QZHG-C5-VN C 3-phase 3-wire unbalanced load 256-TWMW-QZFA-C5-VN C 3-phase 3-wire unbalanced load 256-TWMW-QZHG-C5-VN C 3-phase 4-wire balanced load 256-TWHW-VRFA-C5-VN C 3-phase 4-wire balanced load 256-TWHW-VRHG-C5-VN C 3-phase 4-wire unbalanced load 256-TWNW-VRFA-C5-VN C 3-phase 4-wire unbalanced load 256-TWNW-VRHG-C5-VN C 14 Other Transducers available consult Paladin and Integra 1560/1580 literature. *Please specify, voltage and current transformer ratios and kw range. e.g. 11KV/110V, 200/5A, 0/4MW.
4 253-TAA 253-TAL Dimensions A 35mm 70mm 253-TVA/253-THZ 253-TVL TWL Three-wire system balanced 256-TWH Four-wire system balanced B 50mm (M4) 60mm (M5) 70mm REAR VIEW SHOWING PANEL MOUNTING HOLES 256-TWM Three-wire system unbalanced 256-TWN Four-wire system unbalanced Model A B T*
5 Protector Relays An extensive range of electronic control products providing continuous monitoring and protection of any electrical parameter. When the monitored parameter deviates from the desired set-point limit, the relay will operate to prevent damage to the power asset. Designed to suit a wide variety of applications the range offers both traditional and technologically advanced products, from single parameter units through to multifunctional microprocessor based protection relays. AC Current Relays Aux. 230 AC with Adjustable Time Delay (0-10 seconds) 1-phase 5A CT input, 50/60Hz, 252-PAUW-LSBX-C7- B under-current %. aux 230V ac AM-D1-EB 1-phase 5A CT input, 50/60Hz, 252-PAOW-LSBX-C7- B over-current %. aux 230V ac AM-D1-EA 1-phase 5A CT input, 50/60Hz, 253-PADW-LSBX-C7- B under/over-current %. AM-D1-EC aux 230V ac 3-phase 3 or 4-wire 5A CT input, 253-PAVW-LSBX-C7- B 50/60Hz, under-current %. AM-D1-EB aux 230V ac 3-phase 3 or 4-wire 5A CT input, 253-PAPW-LSBX-C7- B 50/60Hz, over-current %. AM-D1-EA aux 230V ac AC Voltage Relays with Adjustable Differential 1-phase 230V 50Hz 252-PVUW-RQBX-C5-EB B under-voltage % 1-phase 230V 50Hz 252-PVOW-RQBX-C5-EA B over-voltage % 1-phase 230V 50Hz 253-PVBW-RQBX-C5-EC B under/over-voltage 3-phase 3-wire 400V L-L 50Hz 253-PVMW-SCBX-C5-EC B under/over-voltage 3-phase 4-wire 230V L-N 50Hz 253-PVEW-RQBX-C5-EC B under/over-voltage Phase Sequence and Phase Failure Relay 3-phase 3 or 4-wire 400V L-L phase 252-PVRW-SCBX-C5 B sequence and under-voltage 80% Frequency Relay 1-phase 2-wire 230V L-L or L-N 252-PHUW-RQBX-C5-EB B under-frequency (nominal 50Hz) 1-phase 2-wire 230V L-L or L-N 252-PHOW-RQBX-C5-EA B over-frequency (nominal 50Hz) 1-phase 2-wire 230V L-L or L-N 253-PHDW-RQBX-C5-EC B under/over-frequency (nominal 50Hz) 1-phase 2-wire 400V L-L or L-N 253-PHDW-SCBX-C5-EC B under/over-frequency (nominal 50Hz) Synchro-Check (Parallelling) 1-phase, or 3-phase 3- or 4-wire 256-PLLW B phase angle and voltage 1-phase, or 3-phase 3- or 4-wire 256-PLDW B phase angle and voltage dead bus Reverse Power (Current) 16 1 or 3-phase 4-wire 230V L-N, 256-PASW-LSBX-RQ-C5-EA B 5A, 50Hz. Reverse power protection 2-20% 3-phase 3-wire 400V L-L, 5A, 50Hz 256-PATW-LSBX-SC-C5-EA B Reverse power protection 2-20%
6 Dimensions Connections 253-PAP Format mm (2.8 ) 55mm (2.2 ) 35mm (1.37 ) 112mm (4.4 ) 35mm (1.37 ) 17.5mm (0.68 ) 55mm (2.2 ) 35mm (1.37 ) 2 HOLES Ø mm (0.5 ) 15.5mm (0.6 ) 1 Relay Contact Set PVM 2 Supply 3 Relay Contact Set 2 Format mm (2.9 ) 112.5mm (4.4 ) 60mm (2.4 ) 35mm (1.37 ) 70mm (2.8 ) 50mm (1.96 ) 60mm (2.36 ) 252-PVR Contact Set 1 Relay Contact Set 2 Format mm (5.9 ) 135mm (5.3 ) 253-PHD Under Relay Contact Set 1 Over Relay Contact Set 1 Under Relay Contact Set 2 Over Relay Contact Set mm (4.4 ) 256-PAS/256-PAT 256-PAQ/256-PAR 70mm (2.8 ) Volts Single-phase 3-phase 4-wire 3-phase 3-wire Contact Set 1 Contact Set 2 Output Relay Amps Format 256-PLD and 256-PLL 17
Integra 1560 and 1580 Digital Transducer Systems
Integra 1560 and 1580 multi function transducers provide high accuracy
More informationCrompton Instruments Integra and Paladin Transducers
Crompton Instruments Integra and Paladin Transducers Integra and Paladin Transducers An extensive range of transducers providing measurement, isolation and conversion of electrical parameters into industry
More informationMT 560/UMT TRANSDUCER & ANALYZER
MT 560/UMT 560 - TRANSDUCER & ANALYZER USE The MT 560/UMT 560 multi transducer and analyzer is used for a permanent analysis of electricity supply quality in compliance with the SIST EN 50160 standard.
More informationPaladin Transducers 250 Series Class 0.5 and Class 0.2
Paladin Transducers 250 Series Class 0.5 and Class 0.2 An extensive range of transducers providing measurement, isolation and conversion of electrical parameters into industry standard DC output signals.
More informationInstallation and Operating Instructions
Energy Division Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Our commitment. Your advantage. Contents Page 1 Introduction 4 1.1 Measurement Capabilities 5 1.2
More informationALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)
Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA
More informationEnergy Division
Energy Division http://energy.tycoelectronics.com Installation and Operating Manual Integra 1560 and 1580 Digital Metering and Transducer Systems Tyco Electronics UK Limited Crompton Instruments Freebournes
More informationData Sheet. RISH Master Record %THD
Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy
More informationRISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:
Application : RISH Master 3430 measures important electrical parameters in 3 phase and single phase Network & replaces the multiple analog panel meters. It measures electrical parameters like AC current,
More informationInstallation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems
Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Tyco Electronics UK Limited Crompton Instruments Freebournes Road, Witham, Essex, CM8 3AH, UK Tel: +44 1376 509 509
More informationENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID
Professionally approved products. Datasheet Stock Number: 144-0527 3 Phase Multi-function Power Meter 1/5A MID 96mm² Panel Mounted Power Meter. MID UK Specifications The 144-0527 is a new generation modern
More informationRISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:
Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit
More informationALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)
Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA
More informationApplication Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters
Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel
More informationRISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:
(With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network
More informationTechnical Data Sheet AMIK 300 / 301
USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet AMIK 300 / 301 LISTED File No. E471457 AMIK AMIK 300 is a compact multifunction instrument with touch screen LCD utility which measures important
More informationAMIK 200 / 201 Technical Data Sheet
AMIK 200 / 201 Technical Data Sheet AMIK Special Features MODBUS (RS-485) Communication available only on Amik 201 On site Programmable CT/PT Ratios User selectable CT Secondary 1A/5A User selectable PT
More informationUNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49
TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact
More informationRISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics
Power Quality Monitor Individual Harmonics measurement upto 56th Harmonics True representation of Voltage & Current waveforms. Phasor Representation of All 3 phases for system analysis Real Time Clock
More informationPaladin Transducers. Class Series
Paladin Class 0.5 250 Series Suitable for driving meters, PLC s and control equipment over long distances Class 0.5 Application in S.C.A.D.A., telemetry control and data acquisition systems High isolation
More informationDigital Multifunction Meter - RISH Integra 2000
Features Four line graphic LCD display 1+ parameters Fast communications Customer configurable Easy to use Output options: 4 x -1mA 4 x 4-2mA 1 or 2 energy pulses Panel mounted Neutral current measurement
More informationDigital Multifunction Instrument - Rish Master 3440
Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,
More informationRISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters
measures important electrical parameters in phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, Power, Energy
More informationTechnical Data Sheet. x1000. kwh R Y B
Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy
More informationEASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter
SDM630MCT-RJV-333mV SDM630MCT-RJA-00mA Three phase multifunction din rail energy meter Plug-in solution; labor saving; wiring mistake free Measures kwh KVarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc.
More informationEnergy Division
Energy Division http://energy.tycoelectronics.com Installation and Operating Manual Integra 1560 and 1580 Digital Metering and Transducer Systems Tyco Electronics UK Limited Crompton Instruments Freebournes
More informationMICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2
PART 1 PART 2 PRODUCTS 2.01 MANUFACTURERS A. Eaton products B.. C.. The listing of specific manufacturers above does not imply acceptance of their products that do not meet the specified ratings, features
More informationMultiCube Multi-Function Electricity Meter. Installation and Operation
MultiCube Multi-Function Electricity Meter Installation and Operation PREFACE MultiCube Operating Guide Revision 1.08 Jan 2007 This manual represents your meter as manufactured at the time of publication.
More informationTransducing electrical quantities Iskra MIS d.d. Measuring Transducers. Features
Measuring Transducers Transducing electrical quantities Iskra MIS d.d. Measuring Transducers Features AC, DC POWER SYSTEM MEASUREMENT MICROPROCESSOR CONTROL HOUSING FOR DIN RAIL MOUNTING IN COMPLIANCE
More informationRI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters
RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current
More informationOperating Guide October 2006
Operating Guide October 2006 Safety 1 Safety This manual represents your meter as manufactured at the time of publication. It assumes standard software. Special versions of software may be fitted, in which
More informationT 1000 PLUS Secondary Injection Relay Test Set
Secondary Injection Relay Test Set Designed for testing relays and transducers Microprocessor controlled With phase angle shifter Frequency generator Test results and settings are saved into local memory
More informationT 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers
Secondary Injection Relay Test Set Designed for testing relays and transducers Microprocessor controlled With phase angle shifter Frequency generator High power outputs Large graphical display Compact
More informationCROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM
CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and
More informationCROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM
CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and
More informationApplication: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary
Application: Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwor & replaces the multiple analog panel meters. t measures electrical parameters lie AC current,, frequency,
More informationGIMA Multi-Function Electricity Meter OPERATOR S MANUAL
GIMA Multi-Function Electricity Meter OPERATOR S MANUAL SIMPSON ELECTRIC COMPANY 520 Simpson Avenue Lac du Flambeau, WI 54538 715-588-3311 FAX: 715-588-7930 Printed in U.S.A. Part No. 06-117285, Edition
More informationPOWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR
POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR The T-W or T-V power transducer converts ac current and voltage signals into a load independent dc signal proportional to active power (watts)
More informationSUPPLY NETWORK ANALYZER CVM-96 SERIES
SUPPLY NETWORK ANALYZER CVM-96 SERIES (Power Demand) INSTRUCTION MANUAL ( M 981 326 / 00B - GB) (c) CIRCUTOR S.A. ----- Supply network analyzer CVM-96 ------ User's manual --- Page No. 1 CVM-96 SUPPLY
More informationT4500 AUTO SYNCHRONIZER T4800 LOAD SHARER T4900 VAR LOAD SHARER
T400 AUTO SYNCHRONIZER OAD SHARER VAR OAD SHARER T400 AUTO SYNCHRONIZER OAD SHARER VAR OAD SHARER GENERATOR CONTRO REAYS T400 AUTO SYNCHRONIZER arsen & Toubro is India s leading engineering, construction
More informationPaladin Advantage Transducers Class 0.2
An extensive range of higher specification transducers offering Class 0.2 measurement of up to eight electrical parameters. This flexible design provides up to 3 analog outputs in one housing, and a digital
More informationMultimeter 500CVD21 RTU500 series
Remote Terminal Units - Data sheet Multimeter 500CVD21 RTU500 series CT/VT interface with 4 voltage and 24 current inputs for direct monitoring of 3/4 wire 0 300 V AC (line to earth), 0...500 V AC (phase
More informationCentrale de mesure Power Meter PM500 Merlin Gerin
Notice d'installation et d'utilisation Installation and user manual Centrale de mesure Power Meter PM500 Merlin Gerin 059473_D Introduction and description Package contents c one PM500 power meter with
More informationMeasuring transducers
Measuring transducers MT4xx and (U)MT5xx Measuring transducer MT440 MT 440 Programmable multifunctional transducer Real time measurements of more than 50 quantities Power accuracy class 0.5 16 adjustable
More informationTechnical Data Sheet
Technical Data Sheet parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters. Special Features Pulse/Limit Switch output (optional) Number of interruption Application
More information200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features
CT ratio Power Harmonics ac+dc 200ADM-P Current Injection System with Phase Shift Features 0-200A output current True RMS metering with 1 cycle capture Variable auxiliary AC voltage/current output with
More informationContents. Introduction and description Package contents Device identification PM Options... 80
Contents 1 Introduction and description Package contents... 77 Device identification... 77 2 Characteristics PM500... 78 Options... 80 3 Installation Front-panel cut-out... 82 Mounting... 82 4 Connections
More informationADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -
ADJUSTABLE SPEED DRIVES HX7 Series 18 Pulse Toshiba HX7 In some industrial applications, users need reliable and efficient adjustable speed drives that do not contribute significant harmonic distortion
More informationPRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID
RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A
More informationUniversal Protective Relay Test Set
AVO INTERNATIONAL BRINGING RELIABILITY TO AMPS VOLTS OHMS MULTI-AMP Model SR-98 Digital Signal Processor Based technology High Current/High Power output New CA mode captures high speed trip on MCCB 0 to
More informationEM-72 Electricity Meters for Current Transformers
Product sheet MT8.18 Meter EM72 EM-72 Electricity Meters for Current Transformers EM72 electricty meters have been designed for panel mounting to monitor electricity consumption and the quality of the
More informationDIRIS A40 DIRIS A41. Functions. Conformity to standards. Applications. Energy management DIRIS A40. Network analysis
diris_561_b_3_x_cat 1 1. Backlit LCD display. 2. Direct access key for currents and setup wiring correction. 3. Direct access key for voltages and frequency. 4. Direct access key for active, reactive,
More information(240 ) Measurement of DC currents and DC voltages. Size (mm): Q48 Q144 Q72 Q144 Q48 Q144
Panel Meters, Accessories Moving Coil, DQ Moving Coil, VDQ Moving Iron, EQ (240 ) (90 ) Measurement of DC currents and DC voltages. Measurement of AC currents and AC voltages. Measurement of AC currents
More informationEnergy counting and measurement
Energy counting In the current context of research of energy saving, counting of consumption become unavoidable. Hager offers new residential and tertiary solutions, to better control energy consumption.
More informationMeasuring centers MC7x0 series Multifunction Meter MC740
Measuring centers MC7x0 series Multifunction Meter MC740 o Measurements of instantaneous values of more than 130 quantities (U, I, P, Q, S, PF, PA, f, φ, THD, MD, energy, energy cost by tariffs, etc.)
More informationDIRIS A40 Multifunction meters - PMD Multi-measurement meter - dimensions 3.78 x 3.78 in/96 x 96 mm
Single-circuit metering, measurement & analysis The solution for > Industry > Data centres > Infrastructures Function are panel mounted measurement units which ensure the user has access to all the measurements
More informationMEASURING TRANSDUCERS PROGRAMMABLE TRANSDUCERS
PROGRAMMABLE TRANSDUCERS CONTENTS GENERAL FEATURES, DIMENSIONS STANDARDS, GENERAL TECHNICAL SPECIFICATIONS ORDERING INFORMATION TECHNICAL SPECIFICATIONS - INPUTS, OUTPUTS, AUXILIARY VOLTAGE FOR ALTERNATING
More informationEnergy Management Energy Analyzer Type EM210 MID
Energy Management Energy Analyzer Type Multi-use housing: for both DIN-rail and panel mounting applications MID annex MI-003 (Measuring Instruments Directive) compliant Class B (kwh) according to EN50470-3
More informationVoltech PM3000ACE UNIVERSAL POWER ANALYZER
Voltech PM3000ACE UNIVERSAL POWER ANALYZER Precision Power Analysis from Voltech Voltech launched the worlds first commercially available digital power analyzer, the PM1000, in 1987 and the worlds first
More informationcontrol & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS
S E N S O R S PROGRAMMABLE SENSOR CONTROLLER TX9044 COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS Analogue sensors, temperature devices, frequency inputs and digital sensors direct fingertip
More informationEnergy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302
Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Direct connection up to 65 A (WSx10x) Connection with current transformer (WSx30x) Industrial or meters
More informationDIRIS A40/A41 Multifunction meters - PMD multi-measurement meter - dimensions 96 x 96 mm
Single-circuit metering, measurement & analysis The solution for > Industry > Data centres > Infrastructures DIRIS A4 Function and A4are panel mounted measurement units which ensure the user has access
More informationInstallation Instructions and Reference Handbook. Installation instructions
Installation Instructions and Reference Handbook Multi-instrument MIB 7000/7000C/7020 4189320016B (UK) DEIF A/S Product information Installation instructions Basic operation DEIF A/S, Frisenborgvej 33
More informationRS Pro ENGLISH. Datasheet
Datasheet Article No: 136-5385 Digital AC Ammeter, 48x96, 1Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5387 Digital AC Ammeter, 96x96, 1Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5388 Digital
More informationPOWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL
POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK PP, PP and PB ISO 900 C E R T Y F I K A T 4 mm SERVICE MANUAL Contents Page. APPLICATION... 2. BASIC REQUIREMENTS.... TRANSDUCER SET... 4 4. TECHNICAL
More information400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)
MODEL EM4000ACF Multifunction Transducer for alternating voltage and current Power supply voltages: Suitable for DIN-rail mounting 85 240Vac 400,440Vac 24 65Vdc 100..330Vdc V, A, W, VA, var, Hz, V, Avg.
More informationAlpha 50. Technical Data Sheet. Special Features
Technical ata Sheet lpha 50 lpha 50 is a compact multifunction instrument with touch screen LC utility which measures important electrical parameters in 3 phase and single phase Network & replaces the
More informationSLU SERIES Universal Phase Monitor/Relay SLU-100-ASA and SLU-100-ASD
SLU SERIES Universal Phase Monitor/Relay SLU-100-ASA and SLU-100-ASD Plug-In MILLIMETERS DIN Rail DESCRIPTION Phase Monitor Relays (3-Phase Monitors) provide cost-effective protection against premature
More informationPowerLogic power-monitoring units. PM700 series power meter. Technical data sheet
PowerLogic power-monitoring units PM700 series power meter Technical data sheet 2009 Functions and characteristics The PowerLogic PM700 series power meter offers all the measurement capabilities required
More informationMeasurement and control. Digital instruments and measuring transducers
Measurement and control Digital instruments and measuring transducers M.2 - Digital instruments and measuring transducers Introduction...M2-3 Product selection table...m2-5 DC Series Digital indicator
More informationJewell DPM Power / Power Factor Size 96/96 BEST IN CLASS
Application: The Jewell DPM Power 96x96 series measures system active Power (Import/Export), Reactive Power (Import/Export), Apparent Power & Power Factor of Three Phase and Single Phase Network. It has
More informationINSTALLATION INSTRUCTIONS QUICK START GUIDE. Multi-transducer, MTR-3. Document no.: B SW version 3.0X.X or later
INSTALLATION INSTRUCTIONS QUICK START GUIDE Multi-transducer, MTR-3 Document no.: 4189300022B SW version 3.0X.X or later Table of contents 1. ABOUT THIS DOCUMENT... 3 GENERAL PURPOSE... 3 CONTENTS/OVERALL
More informationn True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)
Tranducers for alternating current/voltage n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) and input current range (for CIP-I) n Available in single or dual output type
More informationApplication and features
Power Measurement Unit PM 2214 Power Measurement Unit PM 2214 Application and features PM 2214 Power supervision / SCADA system Feeder automation / Customized 0.05% high accuracy Cost saving for 4 feeder
More information8101 SPECIFICATION SHEET
2 5 0 7 W a r r e n S t r e e t, E l k h a r t, I N 4 6 5 1 6 U S A 5 7 4. 2 9 5. 9 4 9 5 w w w. A E T e c h r o n. c o m The AE Techron 8101 power supply amplifier features an advanced switchmode design
More informationSmart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC)
Smart Energy & Power Quality Solutions UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC) UMG 96RM UMG 96RM Universal measurement instrument Unrivalled in its class The UMG 96RM is a
More informationAPPLICATIONS DATA SHEET. Product: Single Phase AC/DC Power Meter QI-POWER-485
APPLICATIONS DATA SHEET Product: Single Phase AC/DC Power Meter QI-POWER-485 Renewable energy: 1. PV String Monitoring: the QI-POWER-485 measures DC current up to 50 A and DC voltage up to 1000 V, with
More informationMeasuring Transducer MT4xx series Programmable AC Current Transducer MT418
Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 o RMS AC current or frequency measurements o Current auto range measurements up to 12 A o Frequency measurement range 16 400 Hz
More informationPMAC770 Multifunction Power Meter. Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD.
PMAC770 Multifunction Power Meter Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. Danger and warning! This device can be installed only by professionals. The manufacturer shall not
More informationRS Pro ENGLISH. Datasheet
Datasheet ENGLISH Article No: 136-5390 Digital AC Ammeter, 48x96, 3Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5391 Digital AC Ammeter, 96x96, 3Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5393
More informationT 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers
Secondary Injection Relay Test Set Designed for testing relays and transducers Microprocessor controlled With phase angle shifter Frequency generator Test results and settings are saved into local memory
More informationTechnical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay
Technical Datasheet RELAY-1 RELAY-2 k V Hz RESET ABH TEST True RMS Measurement True RMS Digital Protection V/Hz is used to protect against Over Voltage, Under Voltage, Phase Unbalance, Phase Sequence detection,
More informationPower quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I
Harmonics Temperature input Measurement accuracy 0.5 Memory 4 MByte UMG 104 Energy measurement device for DIN rails Communication Profibus (DP / V0 optional) Modbus RTU Power quality Harmonics up to 40th
More informationProgrammable AC Voltage Transducer MT416
Programmable AC Voltage Transducer MT416 RMS AC voltage or frequency measurements Voltage auto measurements up to 600 V L-N Frequency measurement 16 400 Hz AC or universal wide auiliary power 24 300 Vdc,
More informationDRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System
DRTS-6 Advanced Protection Relay Test Set and Measurement System MULTI-TASKING EQUIPMENT DESIGNED FOR TESTING PROTECTION RELAYS, ENERGY METERS, TRANSDUCERS POWERFUL AND LIGHTWEIGHT HIGH ACCURACY: BETTER
More informationEnergy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications
Energy Management Multifunction indicator Type WM12-DI Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase measurements:
More informationDigital Multifunction Meter - RISH Integra 2000
Digital Multifunction Meter - RISH Integra 2000 Data Sheet www.rishabh.co.in Page 1 of 8 Version: Features nfour line graphic LCD display n100+ parameters nfast communications ncustomer configurable neasy
More informationZiegler EM 1320/30/40
Ziegler EM 1320/30/40 Operating Manual Ziegler EM 1340 2-60-006-00-00483_Rev. C - 9/2014 www.ziegler-instruments.com 1 36 DIGITAL MULTIFUNCTION INSTRUMENT Programmable Multi-function Energy Meter Installation
More information2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.
1.0 Scope This document describes the specification for Toshiba 1000 Series On-Line Uninterruptible Power System (UPS). The UPS will supply a computer grade AC output sine wave which is unaffected by the
More informationTransducers for AC measurement. Types TAP, TAQ, TMF, TAA, TAV, TAC. Measurement of: watt, var, frequency, phase angle, voltage, current
Transducers for AC measurement Types TAP, TAQ, TMF, TAA, TAV, TAC 4921220002E Measurement of: watt, var, frequency, phase angle, voltage, current DEIF A/S Accuracy class 0.5 For mounting on DIN rail Compact
More informationApplications. diris_581_e_1_gb_cat
Multifunction meters EW Applications Ethernet diris_744_a_1_cat PC Main meter panel Monitoring and managing energy for high/low voltage electrical installations Function The and A41 are multifunction meters
More informationPower IT LV Active Filters PQFA - PQFL - PQFT
Power IT LV Active Filters PQFA - PQFL - PQFT The ABB comprehensive solution for active filtering of harmonics Pst Harmonics and Power Quality Harmonics caused by non-linear electrical loads such as variable
More informationULTRA RAPID POWER QUALITY ANALYZER
ULTRA RAPID POWER QUALITY ANALYZER Ultra rapid (cycle by cycle) advanced electrical network analysis Complete network harmonics analysis, up to 63 rd harmonic High visibility, 5 graphic LCD screen with
More informationINTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]
Feature Suit for LV/ HV voltage system Compact design with all real-time measurement Consist of basic unit and optional modules 10 years back-up of integrated energy data Large LCD, high brightness High
More informationMultifunction network analyzer Q15U Q96U2L - Q96U4... Q15E Q96E MCU - MCUH Programmable transducer MCUU
Multifunction network analyzer Q15U2... - Q96U2L - Q96U4... Q15E2... - Q96E2... - MCU - MCUH Programmable transducer MCUU OPERATING MANUAL Ipm0163.8 - Edition 06.09 Langer Messtechnik GmbH Soyerhofstrasse
More informationEnergy Management Energy Analyzer Type EM210
Energy Management Energy Analyzer Type EM210 Multi-use housing: for both DIN-rail and panel mounting applications Current inputs AV option: CT 5A Current inputs MV option: current sensor 333 mv (CTV series)
More informationModel 1133A Power Sentinel. with. Digital Signal Analysis SYNCHRONIZED POWER QUALITY/REVENUE STANDARDS
Model 1133A Power Sentinel with Digital Signal Analysis Synchronized via GPS Revenue Accuracy: 0.025% Power Quality: Harmonics, Flicker, Interruptions Phasor Measurements for Stability & Flow Analysis
More informationRelay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay
Line Monitoring Technical Datasheet RISH RELAY-1 RELAY-2 RISHABH k V Hz True RMS Digital Protection RISH V/Hz is used to protect against Over Voltage, Under Voltage, Phase Unbalance, Phase Sequence detection,
More informationEnergy Management Energy Meter with plug-in Output Modules Type EM4-DIN
Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Degree of protection (front): IP 40 Front dimensions: 9 DIN modules RS 422/485 Serial port by means of optional module Dual pulse
More informationWATT TRANSDUCER. Instruction Manual
WT 9200 WATT TRANSDUCER Instruction Manual IM-2 September 2003 USA: 6428 Ridglea Drive, Watauga, Texas 76148 Tel/Fax 1-817-427-2060/2067 E-mail: wes@westecinstruments.com SPECIFICATIONS Power Supply Input