FACTORY AUTOMATION. MANUAL LC10-* Laying loops for Loop detector LC10-1 and LC10-2

Size: px
Start display at page:

Download "FACTORY AUTOMATION. MANUAL LC10-* Laying loops for Loop detector LC10-1 and LC10-2"

Transcription

1 FACTORY AUTOMATION MANUAL LC10-* Laying loops for Loop detector LC10-1 and LC10-2

2 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.v.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"

3 1 Introduction Contents Target Group, Personnel Symbols Used General safety instructions Product Description Overview Use and Application Indicators and Operating Controls LC10-1-* LC10-2-* Interfaces and connections Dimensions Installation Preparation Laying loops Number of loop windings Loop test Installation Commissioning Test function Loop geometry Loop interference Influencing variables Troubleshooting

4 Introduction 1 Introduction 1.1 Contents This document contains information that you need in order to use your product throughout the applicable stages of the product life cycle. These can include the following: Product identification Delivery, transport, and storage Mounting and installation Commissioning and operation Maintenance and repair Troubleshooting Dismounting Disposal Note! This document does not substitute the instruction manual. Note! For full information on the product, refer to the instruction manual and further documentation on the Internet at The documentation consists of the following parts: Present document Instruction manual Datasheet Additionally, the following parts may belong to the documentation, if applicable: EU-type examination certificate EU declaration of conformity Attestation of conformity Certificates Control drawings Additional documents 1.2 Target Group, Personnel Responsibility for planning, assembly, commissioning, operation, maintenance, and dismounting lies with the plant operator. Only appropriately trained and qualified personnel may carry out mounting, installation, commissioning, operation, maintenance, and dismounting of the product. The personnel must have read and understood the instruction manual and the further documentation. Prior to using the product make yourself familiar with it. Read the document carefully. 4

5 Introduction 1.3 Symbols Used This document contains symbols for the identification of warning messages and of informative messages. Warning Messages You will find warning messages, whenever dangers may arise from your actions. It is mandatory that you observe these warning messages for your personal safety and in order to avoid property damage. Depending on the risk level, the warning messages are displayed in descending order as follows: Danger! This symbol indicates an imminent danger. Non-observance will result in personal injury or death. Warning! This symbol indicates a possible fault or danger. Non-observance may cause personal injury or serious property damage. Caution! This symbol indicates a possible fault. Non-observance could interrupt the device and any connected systems and plants, or result in their complete failure. Informative Symbols Note! This symbol brings important information to your attention. Action This symbol indicates a paragraph with instructions. You are prompted to perform an action or a sequence of actions. 5

6 General safety instructions 2 General safety instructions Note! Read the operating instructions before attempting commissioning. Caution! Installation, connection and adjustments should only be undertaken by specialist personnel. Warning! No safety component for protection of personnel or EMERGENCY-STOP functions. Directives and Standards EU-Directive Standards 2014/30/EU EN :2005 EN :20071A1 : /35/EU EN :20061A 1:2009 6

7 Product Description 3 Product Description 3.1 Overview Together with the inductive loops laid beneath the surface, the LC series loop detectors form a universal sensor system for detecting vehicles. People are not detected. Vehicles that enter the inductive loop change the resonant frequency. This frequency change is measured and analyzed by the microprocessor in the LC10 loop detector. The analysis is automatically and periodically adjusted to the respective loop, ensuring that any changes in the loop inductance caused by temperature, humidity or component age are automatically compensated for. The loop detectors are control units that are fully functional without the need for any other auxiliary equipment once the power supply and an inductive loop have been connected. The inductive loop laid below the surface forms the inductor of a high-frequency oscillating circuit. The metal parts of a vehicle that enters or is located in this wired loop cause the frequency of the oscillation circuit to change. This frequency change is analyzed by the loop detector, and the outputs, which are zero-potential relay contacts, can switch. The switching outputs are relay contacts with a high switching power that can directly control contactors, valves and alternating current motors. The dimensions of the detection area can be adjusted by changing the size and shape of the inductive loops. Figure 3.1 LC10-1 (left) and LC10-2 (right) loop detectors 3.2 Use and Application Possible areas of application for the LC10-* series loop detectors are: Selective vehicle detection Opening impulse sensor for automatic gates and barrier systems Presence checks for vehicles Direction-specific vehicle checks Controlling traffic light and vehicle detection systems Ticket detection in parking garages Managing tasks in automatic conveyor systems 7

8 Product Description 3.3 Indicators and Operating Controls LC10-1-* 1 2 ON OFF ON DIP BOOST MODE FREQ. 1 LED indicator 2 DIP switch LED indicator LED signals the allocation state of the loop (Loop allocated = LED On). A fault in the loop due to a short-circuit or lead breakage and loop inductance outside the permissible range is indicated by flashing of LED. DIP switches It is possible to modify frequency, sensitivity and operating mode by using the DIP switch. Sensitivity The response sensitivity of the loop detector can be set in three stages by switches 3 and 4. switch 3 switch 4 sensitivity OFF ON low ON OFF medium ON ON high Table 3.1 Frequency switches In the switch position "OFF", "OFF" the loop evaluation is switched off. The loop frequency can be set in four stages using the switches 1 and 2. switch 1 switch 2 frequency OFF OFF basic frequency f ON OFF f - 10% OFF ON f - 15% ON ON f - 20% Table 3.2 After actuation of the frequency switches 1 and 2 the loop must be readjusted with switches 3 and 4 set to "OFF", "OFF". Operating mode switches The following operating modes can be set with switches 5 and 6: switch 7 switch 8 result OFF - Pulse (0,8 s)when loop is allocated ON - Pulse (0,8 s) when loop is abandoned - ON Increased sensitivity (Boost) Table 3.3 The increased sensitivity (Boost) is used for the detection of vehicles with high body assemblies, e.g. HGVs. 8

9 Product Description LC10-2-* LED indicator loop 2 2 LED indicator loop 1 3 DIP switch LED indicators Indications: LEDs 1 and 2 signal the allocation state of the loops (Loop 1 allocated = LED 1 on, Loop 2 allocated = LED 2 on). A fault in a loop due to a short-circuit or lead breakage and loop industance outside the permissible range is indicated by flashing of the respective LED. DIP switches It is possible to modify frequency, sensitivity and operating mode by using the DIP switch. Sensitivity The response sensitivity of the loop detector can be set in three stages using switches 3 and 4 (for loop 1) and switches 5 and 6 (for loop 2). switch 3 or 5 switch 4 or 6 sensitivity OFF ON low ON OFF medium ON ON high Table 3.4 Frequency switches In the switch position "OFF", "OFF" the loop evaluation is switched off. The loop frequency can be set in four stages using the switches 1 and 2. switch 1 switch 2 frequency OFF OFF basic frequency f ON OFF f - 10% OFF ON f - 15% ON ON f - 20% Table 3.5 After actuation of the frequency switches 1 and 2 the loop must be readjusted with switches 3 and 4 set to "OFF", "OFF". CH2 CH1 ON OFF ON DIP BOOST MODE CH2 CH1 FREQ. CH1 9

10 Product Description operating mode switches The following operating modes can be set with switches 7 and 8: switch 7 switch 8 result OFF - Output of the loop allocation status ON - Direction detection* - ON Increased sensitivity (Boost) Table Interfaces and connections *A signal is output, depending on the allocation sequence of the loops. If loop 1 is allocated before loop 2, only one switch signal is output for loop 1. The signal output for loop 2 remains inhibited until both loops are free again. If loop 2 is allocated before 1, only one switch signal is output for loop 2. The signal output for loop 1 remains inhibited until both loops are free again. The increased sensitivity (Boost) is used for the detection of vehicles with high body assemblies, e.g. HGVs. Connections LC Number Explanation Connector terminals 3 Loop connection 7/8 4 Signal output, maintained contact 5/6 = NO 6/10 = NC 5 signal output, 3/4 = NO 4/11 = NC 6 Operating voltage 1/2 10

11 Product Description Connections LC10-2 SL 1 SL SL 1 SL Dimensions Number Explanation Connector terminals 4 Loop connection, Loops 1/2 7/8 = loop 1 8/9 = loop 2 5 Signal output, Loop 1 5/6 = NO 6/10 = NC 6 Signal output, Loop 2 3/4 = NO 4/11 = NC 7 Operating voltage 1/2 27 Figure 3.2 Dimensions LC10-1 and LC

12 Installation 4 Installation 4.1 Preparation Laying loops Laying loops in asphalt or concrete floors When laying loops in asphalt or concrete floors the loop can be produced in commercial grade insulated copper braid HO7V-K1.5(NYAF) with a cross section of 1.5 mm². A groove approx. 8 mm wide and mm deep is cut into the floor. The groove must be cleared of all residue and the wires of the loop inserted as deep as possible and fixed in place. The groove is then refilled with artificial resin or bitumen. The connection lead for the loop is twisted (at least 20 times per meter) and then also laid in a groove or a conduit to the loop detector. The connection lead should not exceed a length of max. 150 m. 8 mm mm Laying loops under composite paving When laying loops under composite paving the loop must be laid permanently in a plastic pipe in a sand bed. We recommend to lay the loops in a plastic conduit. The loop must not be laid in groove cut into the composite paving. Composite pavement Completed loop Number of loop windings Layer of sand The induction loop consists of several copper wire windings which are inserted into the floor groove. The number of windings depends on the size of the loop and can be calculated from the loop circumference in accordance with the following table. Loop circumference U: U=2a+2b a b Figure 4.1 e.g.: a = 3 m; b = 1 m; U = 2 x 3 m + 2 x 1 m = 8 m; Number of windings = 4 Loop circumference Number of windings 2-4 meters meters meters meters 3 12

13 Installation Loop test Adjacent loops of the same circumference should differ from each other by 1 winding. This prevents the loops from operating on the same frequency. After laying and sealing the insulating resistance of the loop must be measured against earth. It must be at least 1 MOhm. Important notice! 4.2 Installation 1. When laying in asphalt/concrete the loop must be buried deep enough not to be pressed back out under driving load. 2. Twist the loop connection lead well (at least 20 times per meter) and lay permanently. 3. Firmly embed the loop and the connection lead. Loop movements can result in false alarms. 4. Solder the connection points in the loop connection lead and insulate them well (e.g. distribution box + sealing) 5. Lay loop connection lead separately from high voltage cables. 6. Lead the connection lead also twisted in the switch cabinet up to the terminals of the loop detector. 7. Do not lead loops over resistance mats of floor heating installations. Installation LC10-* The loop detectors are constructed within the 11-pole plug-in socket housing and can be installed directly in switch cabinets. They can be fixed either on a 35 mm top hat rail or via screw connections. Direct installation at the induction loop on location is also possible through integration in an ISO housing. This method of installation is recommended for long loop connection leads. During switch cabinet installation care must be taken not to install the loop detectors directly next to switch contactors for high voltage consumers in order to prevent interference. Connection LC10-* Loop detectors are control devices which are fully ready for operation without the need for additional equipment when connected to the supply voltage and the induction loop. The switching outputs are relay contacts with high breaking capacity which can directly trigger contactors, valves and alternate current motors. To reduce potential interference it is recommended to fit inductive consumers with R/C protective circuits (47 Ohm / 0.1 µf). The loop connection lead must be well twisted (at least 20 times per meter) all the way to the connection terminals of the loop detector. The loop connection lead must be laid separately from switching cables of high voltage consumers (not in the same cable conduit). The proper design and correct laying of the loop are preconditions for the proper functioning of the loop detector. 13

14 Commissioning 5 Commissioning When the operating voltage is applied to the device automatic adjustment with the loop takes place. The output relays are switched in the switch position "loop not allocated". The adjustment takes 2 s, then the device is ready for operation. Automatic adjustment also takes place when both sensitivity switches 3 and 4 (Loop 1) and 5 and 6 (Loop 2) are set to "OFF" and then set to another switch position. The adjustment can be carried out separately for loop 1 and loop Test function The loop detector is provided with an integrated test function, which enables the loop frequency and sensitivity to be optimally set without additional devices or instrumentation. Display of the recommended sensitivity The vehicle must be driven onto the loop. The loop detector measures and stores the frequency change. When switches 3 and 4 are changed over the recommended sensitivity is indicated by flashing of LED 1 (Loop 1). In addition to LC10-2: When switches 5 and 6 are changed over the recommended sensitivity is indicated by flashing of LED 2 (Loop 2) LED Adjust sensitivity step 3 Measurement of the loop frequency The loop frequency can be measured via the LED. Set switches 3 and 4 from "OFF" to "ON". The LED indicates the loop frequency via a signal sequence: LED loop frequency 33 khz 5.2 Loop geometry 3 x 10 khz 3 x 1 khz The size and shape of the loop are determined by the respective application. Generally, the maximum sensitivity of the induction loop is achieved if the loop is no larger than the vehicle to be detected. This principle must in particular be observed if the sensitivity is reduced by steel reinforcements within the floor. Erfassung von PKWs und Gabelstaplern roadway ~ 0,5 m driving direction 1,5m 14

15 Commissioning Erfassung von LKWs roadway ~ 1 m driving direction Erfassung von Zweirädern (Motorrad, Fahrrad) Schleifen mit verringerter Seitenempfindlichkeit 5.3 Loop interference Interference from adjacent loops Loops connected to different loop detectors must have a minimum distance of 2 meters from each other and operate on different frequencies. For loops connected to a double detector this minimum distance can be reduced. However, it must be ensured that the two loops do not operate on the same frequency. 2 m roadway 0,9 m 0,2 m 45 driving direction 1 m Sliding doors Selection gates Folding doors 15

16 Commissioning > 2 m SD IND 2.1 SD IND 1.1 > 2 m SD IND 1.1 SD IND 1.1 Interference from metal Fixed metal constructions e.g. steel girders, drains, steel reinforcements are integrated in the automatic compensation of the loop detector and do not affect the safe functioning except for a reduced sensitivity. Moveable metal constructions e.g. rolling doors and revolving doors must have a sufficiently large distance to the loop (> 1 meter) to prevent triggering the loop detector when moving. 5.4 Influencing variables Loop inductivity The recommended number of windings is only dimensioned for a loop inductivity of approx. 200 µh. At this loop inductivity no significant reduction of sensitivity results from a connection lead of up to 50 meters. For longer connection leads (up to max. 150 m) the loop inductivity should be increased by increasing the number of windings. Loop resistance The total resistance of loop connection leads and contact resistances should not exceed 5 Ω. The cross section of the loop connection lead should be 1.5 mm². Steel reinforcements Steel reinforcements in the floor reduce the loop sensitivity. With heavy reinforcements the loop size should be adjusted optimally to the vehicle size (no large loops) in order to keep the loss of sensitivity low. Laying loops The loops must be permanently laid in the floor to prevent malfunctioning due to mechanical movement. Especially when laying between rail tracks a firm installation and the use of a stable complete loop should be ensured. Connecting loops in series Connecting loops in series (e.g. opening loops on the inside and outside of gates) considerably reduces the sensitivity (approx %). In such cases we recommend the use of the twochannel loop detector LC10-2. Insulation resistance Insufficient insulation resistance of the loop to earth, to adjacent loops or of the windings to each other can cause malfunctioning. When laying loops it must be ensured that the line insulation is not damaged by sharp edges in the floor groove. 16

17 Troubleshooting 6 Troubleshooting Before requesting a service call, please check that the following actions have been taken: Equipment has been tested according to the following checklists. Telephone assistance has been obtained from the Service Center in order to isolate the problem. Interference The settings of the DIP switches (ON/OFF) were reviewed according to the instruction manual. The relay is connected straight and tightly to the plug-in socket. All 11 connecting cables were screwed properly and stable to the corresponding plug-in socket. All 11 connection terminals are clean and free from any dirt. The inductive loop(s) were installed properly. (see laying instructions for inductive loops) Fault Analysis Source of Fault Cause Action By using a two-channel loop detector both channels are responding identically. The loop detector doesn't react or has contact issues. The loop detector doesn't react to high vehicles. The loop detector is triggered without any passing vehicle. Both detectors are working on the same frequency. The connections are dirty. Insufficient sensitivity. The distance between inductive loop(s) and moveable metallic parts (e.g. gates) is too small. Different inductive loops (in length and number of loops) must be installed and connected. Please clean the connection terminals with a suitable contact cleaner. (e.g. Contact Chemistry 60) The switching threshold must be increased via the DIP switch (sensitivity boost). The distance between the edge of the inductive loop(s) and moveable metallic parts must be at least 1 metre. 17

18 FACTORY AUTOMATION SENSING YOUR NEEDS Worldwide Headquarters Pepperl+Fuchs GmbH Mannheim Germany Tel USA Headquarters Pepperl+Fuchs Inc. Twinsburg, Ohio USA Tel Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd. Company Registration No E Singapore Tel Subject to modifications Copyright PEPPERL+FUCHS Printed in Germany / DOCT0973C 11/2016

ORIGINAL INSTRUCTIONS

ORIGINAL INSTRUCTIONS FACTORY AUTOMATION ORIGINAL INSTRUCTIONS Safety light grid SLP series The latest version of the General Terms of Supply for Products and Services in the Electronics Industry issued by the German Electrical

More information

SMARTSCAN INFORMATION

SMARTSCAN INFORMATION SMARTSCAN INFORMATION SS SLC NOV05 SLC2 and SLC4 SAFETY INDUCTIVE LOOP CONTROLLERS INSTALLATION GUIDE Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954,

More information

Connection and installation manual. Induction loop detector ISD 4, ISD 4/2

Connection and installation manual. Induction loop detector ISD 4, ISD 4/2 Connection and installation manual Induction loop detector ISD 4, ISD 4/2 warning and safety notes These installation and operating instructions form an integral part of the product. They have been specifically

More information

Short form User Manual

Short form User Manual Nortech Detection Pty Ltd Unit1, Bldg 5, Forest Central Business Park, 49 Frenchs Forest Road, Frenchs Forest NSW 2086 PO Box 6011, Frenchs Forest DC, NSW 2086 Tel: 02 8977 4047 Fax: 02 9475 4742 email:

More information

TECHNICAL MANUAL FOR LOOP DETECTORS WITH POWERFAIL MEMORY Article Codes: RDET1CM & RDET2CM

TECHNICAL MANUAL FOR LOOP DETECTORS WITH POWERFAIL MEMORY Article Codes: RDET1CM & RDET2CM TECHNICAL MANUAL FOR LOOP DETECTORS WITH POWERFAIL MEMORY Article Codes: RDET1CM & RDET2CM THIS MANUAL IS INTENDED FOR FOREMEN AND TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, OPERATION AND MAINTENANCE

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

Operating Instructions

Operating Instructions UltraDTEK Vehicle Loop Detector Operating Instructions PRODUCT OVERVIEW The UltraDTEK vehicle loop detector is plug-in compatible with Elite OmniControl TM board operators and other Elite A ELD enabled

More information

Single Channel Loop Detector

Single Channel Loop Detector Single Channel Loop Detector Model - LD160 Series The LD160 is a single channel inductive loop detector designed for traffic control applications. The detector is connected to an inductive loop mounted

More information

Single Channel Loop Detector

Single Channel Loop Detector Single Channel Loop Detector Model - LD116 The LD116 is a single channel inductive loop card detector designed for parking and access control applications. The detector is connected to an inductive loop

More information

Single Channel Loop Detector

Single Channel Loop Detector Single Channel Loop Detector Model - LD106 Series The LD106 is an ultra low power single channel inductive loop detector designed for parking and access control applications. The LD106 can be configured

More information

Single Channel Loop Detector

Single Channel Loop Detector Single Channel Loop Detector Model - LD113 Series The LD113 is a single channel inductive loop card detector designed for parking and access control applications. The detector is connected to an inductive

More information

ULT-MVP O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

ULT-MVP O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128 ULT-MVP ULTRALOOP O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com

More information

PD132 Loop Detector Specification

PD132 Loop Detector Specification PD132 Loop Detector Specification (Version 1.00) Content 1. Application... 3 2. Technical Data... 3 3 Wiring Diagram... 3 4 Use and operational... 4 4.1 Frequency adjust... 4 4.2 Sensitivity adjust...

More information

Single Channel Loop Vehicle detector User Manual

Single Channel Loop Vehicle detector User Manual Single Channel Loop Vehicle detector User Manual 1 Introduction CE-L02-J9 is a single channel digital inductive loop vehicle detector. It is used to identify the presence of vehicle by means of an inductive

More information

ULT-DIN O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

ULT-DIN O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128 O P E R A T I N G I N S T R U C T I O N S ULT-DIN ULTRALOOP V E HI C L E L O O P DETECTOR 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com

More information

FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR

FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR 1. Introduction The FLUX 11 is a single channel plug-in inductive loop detector designed for vehicle access applications, and interfaces

More information

AGP-0230 USER MANUAL AMANO

AGP-0230 USER MANUAL AMANO This document is for information only and unless otherwise indicated it is not to form part of any contract. In accordance with the manufacturer s policy of continually updating and improving design, specifications

More information

PROCESS AUTOMATION MANUAL FIELDBARRIER

PROCESS AUTOMATION MANUAL FIELDBARRIER PROCESS AUTOMATION MANUAL FIELDBARRIER SCHULUNG V2 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services

More information

Operating Instructions

Operating Instructions ULT-PLG ULTRALOOP Vehicle Loop Detector Operating Instructions CAUTIONS AND WARNINGS CE REQUIREMENT: Use EMX Pre-formed loops with built-in surge suppression for CE compliance. Connect shield on lead in

More information

Loop Installation. Manual.

Loop Installation. Manual. Loop Installation Manual www.rogertechnology.com Contents 1 General 2 Operating mode 3 Safety notes 4 Induction loop 4.1 Loop size and number of turns 4.2 Inductivity of the loop 5 Loop installation 5.1

More information

MD12-2 Metal Loop Detector

MD12-2 Metal Loop Detector MD12-2 Metal Loop Detector Features Supply 12VDC Adjustable sensitivity (8 levels via dip switch) 2 x Relay outputs (each can be configured individually) Power up and loop activation LED indicator. Industry

More information

USERS GUIDE MATRIX2 DIGITAL INDUCTIVE LOOP SENSORS

USERS GUIDE MATRIX2 DIGITAL INDUCTIVE LOOP SENSORS We open up New Horizons USERS GUIDE MATRIX2 DIGITAL INDUCTIVE LOOP SENSORS APPLICATION The MATRIX is a Digital Inductive Loop Detector used for the detection of vehicular traffic. The MATRIX is the ideal

More information

Operating instructions Fail-safe delay timer AZS About this document. Content

Operating instructions Fail-safe delay timer AZS About this document. Content 8 Appendix 8.1 Wiring example...4 8.2 Integral System Diagnostics (ISD)....5 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101126753-

More information

USERS GUIDE MATRIX P/N SINGLE DIGITAL INDUCTIVE LOOP SENSOR

USERS GUIDE MATRIX P/N SINGLE DIGITAL INDUCTIVE LOOP SENSOR USERS GUIDE MATRIX P/N 17500001 SINGLE DIGITAL INDUCTIVE LOOP SENSOR APPLICATIONS The MATRIX Digital Inductive Loop Detector is the ideal solution for parking barrier control, motorized gates and doors,

More information

FG2 TWO-CHANNEL DETECTOR

FG2 TWO-CHANNEL DETECTOR FG TWO-CHANNEL DETECTOR. DIMENSIS AND ELECTRIC CNECTIS ENGLISH 4 VDC 4 Vdc power supply 3 4 5 6 7 8 9 0 Loop contact Loop contact Loop Loop Dimensions in mm. GENERAL INFORMATI Applications: control of

More information

BEA s digital inductive single loop solution

BEA s digital inductive single loop solution BEA s digital inductive single loop solution Matrix2-S With more standard features than any other loop detector on the market, the Matrix2-S has the flexibility, compatibility and performance to maximize

More information

MU110-16R(K) Digital output module 16 channel. User guide

MU110-16R(K) Digital output module 16 channel. User guide MU110-16R(K) Digital output module 16 channel User guide MU110-16R(K)_2016.12_0220_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Germany

More information

Installation Instructions for the 50FY Series Hall Effect Door Interrupt System, EN954 Category III

Installation Instructions for the 50FY Series Hall Effect Door Interrupt System, EN954 Category III Installation Instructions for the 50FY Series Hall Effect Door Interrupt System, EN954 Category III IMPROPER INSTALLATION This product is designed to conform to the technical requirements of EN954 Category

More information

Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02

Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02 Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02 Installation Guide WirelessSet485-IEN091511 98-0009411 Version 1.1 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes

More information

English. Operating manual. Temperature measuring transducer MU125. Save for later reference. Company / brands of GHM

English. Operating manual. Temperature measuring transducer MU125.  Save for later reference. Company / brands of GHM English Operating manual Temperature measuring transducer MU125 Company / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents Page 1. Intended use (areas of application)...

More information

MU110-8R(K) Digital output module 8 channel. User guide

MU110-8R(K) Digital output module 8 channel. User guide MU110-8R(K) Digital output module 8 channel User guide MU110-8R(K)_2019.01_0296_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Germany

More information

FARTHER THAN YOU CAN SEE OPTICAL DISTANCE MEASUREMENT WITH VDM100 FACTORY AUTOMATION

FARTHER THAN YOU CAN SEE OPTICAL DISTANCE MEASUREMENT WITH VDM100 FACTORY AUTOMATION FARTHER THAN YOU CAN SEE OPTICAL DISTANCE MEASUREMENT WITH VDM100 FACTORY AUTOMATION VDM100 DISTANCE MEASUREMENT UP TO 300 METERS Farther than you can see Indeed! The new VDM100 works perfectly in distances

More information

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Installation and Operational Instructions for ROBA -switch Type 017._00.2 OBA -switch Type 017._00.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EC Low Voltage Directive 2014/35/ EC and the EMC Directive

More information

601/602 Series Inductive Loop Detector

601/602 Series Inductive Loop Detector 601/602 Series Inductive Loop Detector Installation Guide Sarasota Series Detectors 1 Copyright 2009 Peek Traffic Corporation Printed in the USA. All rights reserved. Information furnished by Peek is believed

More information

Single Channel Loop Detector

Single Channel Loop Detector Single Channel Loop Detector Model LD120T Series The LD120T is a series of single channel inductive loop detectors. The use of microprocessor and surface mount technology enables a large number of functions

More information

External brake resistor AX2090-BW5x

External brake resistor AX2090-BW5x Documentation External brake resistor AX2090-BW5x Accessories for Beckhoff servo drive AX5000 Version: Date: 1.3 2018-03-14 Table of content Table of content 1 Foreword... 5 1.1 Notes on the documentation...

More information

Dual Channel Vehicle Detector ULD 920 USER MANUAL Part Number: MIC ULD 920

Dual Channel Vehicle Detector ULD 920 USER MANUAL Part Number: MIC ULD 920 Dual Channel Vehicle Detector ULD 920 USER MANUAL Part Number: MIC0302036 ULD 920 October 2003 Revision: 03 I N D E X PAGE Detector Commissioning... 1 Frequency... 1 Sensitivity... 1 Automatic Sensitivity

More information

Operations Manual. Model NT11 & NT11-E. June 18 th 2002

Operations Manual. Model NT11 & NT11-E. June 18 th 2002 Operations Manual Model NT11 & NT11-E June 18 th 2002 3609 North 44 th Street Phoenix, AZ 85018-6023 Internet: www.northstarcontrols.com Fax: (941) 426-0807 Tel: (941) 426-6396 Manual Contents Glossary

More information

INSTRUCTION MANUAL DAAB LOOP DETECTOR DB402

INSTRUCTION MANUAL DAAB LOOP DETECTOR DB402 INSTRUCTION MANUAL DAAB LOOP DETECTOR DB402 1st Edition Revision: 3 FAAC Nordic AB BOX 125, SE-284 22 PERSTORP SWEDEN TEL. +46 435 77 95 00 FAX +46 435 77 95 29 www.faac.se Contents Technical data...2

More information

MATRIX INDUCTIVE LOOP CONTROL BOX

MATRIX INDUCTIVE LOOP CONTROL BOX EN MATRIX INDUCTIVE LOOP CTROL BOX MATRIX-S2-24: single loop with 2 to 24 V AC/DC power supply MATRIX-D2-24: double loop with 2 to 24 V AC/DC power supply MATRIX-S220: single loop with 220 to 240 V AC

More information

ID ANTRW.8060-A ID ANTRW.5040-A

ID ANTRW.8060-A ID ANTRW.5040-A Installation Manual Shield antenna ID ANTRW.8060-A ID ANTRW.5040-A (for ID RW24.ABC-A) Delivery contents: 1 x ID ANTRW.8060-A or ID ANTRW.5040-A 4 x capping plugs 10mm 1 x Installation manual M00102-0e-ID.doc

More information

ENS31 Automatic Isolation Unit Product Description

ENS31 Automatic Isolation Unit Product Description ENS31 Automatic Isolation Unit Product Description Issue 09/2005 UfE Umweltfreundliche Energieanlagen GmbH Joachim-Jungius-Straße 9 D 18059 Rostock Tel.: +49 3 81 / 405 97 05 Fax: +49 3 81 / 405 97 03

More information

Loop Installation. Manual

Loop Installation. Manual Manual Weiss-Electronic GmbH Niederkircher Straße 16 54294 Trier Germany http://www.weiss-electronic.de 2006 All rights reserved Tel.: +49 (0) 6 51 / 8 10 02 0 2/20 Contents 1 GENERAL DESCRIPTION... 4

More information

Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs

Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs Operating Manual Out 1 sin / cos 1Vpp Input: sin / cos 1 Vpp Out 2 sin / cos 1Vpp Out 3 sin / cos 1Vpp SV 211 Out 4 sin / cos 1Vpp Interface type SV211 SinCos signal splitter with 4 SinCos outputs Product

More information

USER MANUAL ULD 910. October 2003 Revision: 03. Single Channel Vehicle Detector ULD 910. Part Number: MIC

USER MANUAL ULD 910. October 2003 Revision: 03. Single Channel Vehicle Detector ULD 910. Part Number: MIC Single Channel Vehicle Detector ULD 910 USER MANUAL Part Number: MIC0302004 ULD 910 October 2003 Revision: 03 I N D E X PAGE Detector Commissioning... 1 Frequency... 1 Sensitivity... 1 Automatic Sensitivity

More information

Nsg inductive switch transient test circuit

Nsg inductive switch transient test circuit 1 Nsg 5071 - inductive switch transient test circuit User Manual 601-327A Nsg 5071 - inductive switch transient test circuit User Manual NSG 5071 Inductive switch transient test circuit Contents 1 Explanation

More information

Increasing security. Saving space. Gaining flexibility. Signal Conditioners for Industrial Automation

Increasing security. Saving space. Gaining flexibility. Signal Conditioners for Industrial Automation Increasing security. Saving space. Gaining flexibility. Signal Conditioners for Industrial Automation The SC-System: Interference-Free Signals, Maximum Performance The SC-System from Pepperl+Fuchs offers

More information

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Original operating instructions Fail-safe inductive sensor GM504S / / 2010 Original operating instructions Fail-safe inductive sensor GM504S 704070 / 01 06 / 2010 Contents 1 Preliminary note 3 1.1 Explanation of symbols 3 2 Safety instructions 4 2.1 Safety-related requirements

More information

Position Transmitter TGS 40 (RAM)

Position Transmitter TGS 40 (RAM) Operating Instructions 42/14-50 EN Position Transmitter TGS 40 (RAM) Position Transmitter TGS 40 (RAM) Operating Instructions Document no. 42/14-50 EN Date of issue: 05.2006 Revision: B Manufacturer: ABB

More information

SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam

SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam User Manual SBeamRep-BEN091911 98-0002611 Version 1.1 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this Manual..............................

More information

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELECTRICAL ENGINEERING DIVISION Distribution Network Department SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELA T150.2 en SRA 2250/6 Resistor specification The SRA 2250/6 Resistor is intended to increase

More information

Operating Instructions. for. Controller SMS 150 / 151

Operating Instructions. for. Controller SMS 150 / 151 Operating Instructions for Controller SMS 150 / 151 Contents Controller SMS 150 / 151... 1 Contents... 2 Reserve... 2 1. Safety instructions for users... 3 2. Application... 4 3. Warnings... 5 4. Installation...

More information

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions Isolators, Isolator / Power Supplies Operating Instructions EN Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized

More information

Operating Instructions

Operating Instructions Operating Instructions FLUDEX-EOC system A. Friedr. Flender AG 46393 Bocholt Tel. 02871/92-0 Telefax 02871/92-2596 www.flender.com Contents 1. Application 3 2. Operation 3 3. Fitting 4 3.1 Fitting transmitter

More information

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/ EU and the Electromagnetic Compatibility (EMC)

More information

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OWNER S MANUAL Model 5100F RF POWER AMPLIFIER 0.8 2.5 GHz, 25 Watts Ophir RF 5300 Beethoven Street Los Angeles, CA 90066

More information

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail Current/Voltage Trip Value Features Assembly 1-channel signal conditioner 24 V DC supply (Power Rail) Current and voltage input 2 relay outputs Programmable high/low alarm Configurable via DIP switches

More information

Univox CLS-5. Environment-friendly loop amplifier for TV rooms and installations in elevators/buses. Installation Guide

Univox CLS-5. Environment-friendly loop amplifier for TV rooms and installations in elevators/buses. Installation Guide Univox CLS-5 Environment-friendly loop amplifier for TV rooms and installations in elevators/buses Installation Guide Univox CLS-5, art nr 212012 1 Content Introduction........ 3 Product overview........

More information

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Original operating instructions Fail-safe inductive sensor GG507S / / 2013 Original operating instructions Fail-safe inductive sensor GG507S 80005283 / 00 05 / 2013 Contents 1 Preliminary note...3 1.1 Explanation of symbols...3 2 Safety instructions...4 2.1 Safety-related requirements

More information

ENS26 Automatic Isolation Unit Product Description

ENS26 Automatic Isolation Unit Product Description ENS26 Automatic Isolation Unit Product Description Issue 09/2005 UfE Umweltfreundliche Energieanlagen GmbH Joachim-Jungius-Straße 9 D 18059 Rostock Tel.: +49 3 81 / 405 97 05 Fax: +49 3 81 / 405 97 03

More information

Underground Loops and Loop Detectors. DoorKing Plug-In Loop Detectors and Loop Accessories Single Channel CH1

Underground Loops and Loop Detectors. DoorKing Plug-In Loop Detectors and Loop Accessories Single Channel CH1 S1 S2A B S1S2 A B S1 S2A O SW1 Information Manual Underground Loops and Loop Detectors DoorKing Plug-In Loop Detectors and Loop Accessories 9411 Single Channel with Aux Relay 9410 Single Channel CH1 CH2

More information

Original operating instructions Fail-safe inductive sensor GG507S

Original operating instructions Fail-safe inductive sensor GG507S Original operating instructions Fail-safe inductive sensor GG507S 80236827 / 00 09 / 2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety instructions...4 2.1 Safety-related

More information

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 0640 807-0 Fax: 0640 807-259 IT system floor-standing distribution cabinet Series -IPS-F/EDS for supplying power to medical locations

More information

Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity

Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity Documentation Measurement and Control Type: ELT-GP1 Content 1. Installation instructions 2. Data sheets 3. Declarations of conformity (Part No. 008Q520) eltherm GmbH Ernst-Heinkel-Str. 6-10 57299 Burbach

More information

Radio receiver E17 2-channel, 27 MHz, 40MHz, or 433 MHz, 2 relay outputs. Operating voltage: 230 V/AC or 12 V or 24 V AC/DC available.

Radio receiver E17 2-channel, 27 MHz, 40MHz, or 433 MHz, 2 relay outputs. Operating voltage: 230 V/AC or 12 V or 24 V AC/DC available. Fig.: 230 V version Radio receiver E17 2-channel, 27 MHz, 40MHz, or 433 MHz, 2 relay outputs. Operating voltage: 230 V/AC or 12 V or 24 V AC/DC available. Installation, connection and programming instructions

More information

Wireless multizone receiver RDE-MZ6

Wireless multizone receiver RDE-MZ6 s 1 428 Wireless multizone receiver RDE-MZ6 for floor heating / zone heating systems Mains-powered RDE-MZ6 multizone wireless receiver (AC 230 V) DIN rail mounting 2-position control with On/Off output

More information

400 MHz Passive High-Voltage Probe R&S RT-ZH

400 MHz Passive High-Voltage Probe R&S RT-ZH Manual 400 MHz Passive High-Voltage Probe R&S RT-ZH11 1409.7737.02 Printed in Germany Test and Measurment Manufacturer ROHDE & SCHWARZ For comprehensive information about Rohde and Schwarz, please visit

More information

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER MANUAL 600A AC Clamp Meter + NCV Model MA610 USER MANUAL 600A AC Clamp Meter + NCV Model MA610 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA610 Clamp Meter. This meter measures

More information

Inductive Loop Detector

Inductive Loop Detector Naztec Operations Manual For Inductive Loop Detector Model 722TXC TS1/TS2 April 2003 Published by: Naztec, Inc. 820 Park Two Drive Sugar Land, Texas 77478 Phone: (281) 240-7233 Fax: (281) 240-7238 Copyright

More information

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SL acc. to EC

More information

TETRIS 1000 High Impedance Active Probe. Instruction Manual

TETRIS 1000 High Impedance Active Probe. Instruction Manual TETRIS 1000 High Impedance Active Probe Instruction Manual Copyright 2015 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

400Amp True RMS AC Clamp Meter + NCV

400Amp True RMS AC Clamp Meter + NCV User Guide 400Amp True RMS AC Clamp Meter + NCV Model MA410T Introduction Thank you for selecting the Extech MA410 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,

More information

Rosemount 5408 and 5408:SIS Level Transmitters

Rosemount 5408 and 5408:SIS Level Transmitters Quick Start Guide 00825-0100-4408, Rev AD March 2018 Rosemount 5408 and 5408:SIS Level Transmitters Cone Antenna Quick Start Guide March 2018 1 About this guide This Quick Start Guide provides basic guidelines

More information

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español Owner's Manual AC/DC Clamp Meter Model No. 82369 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

EY-EM 527: Remote I/O module, ecolink527

EY-EM 527: Remote I/O module, ecolink527 Product data sheet 94.078 EY-EM 527: Remote I/O module, ecolink527 How energy efficiency is improved Regulation, control, monitoring and optimisation of operational systems, e.g. room automation or HVAC

More information

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems 3 041 RCU10 RCU10.1 Room Temperature Controllers for heating and cooling systems RCU10... Choice of two-position or modulating PI control ON / OFF or PWM outputs for heating and cooling Operating modes:

More information

The frequency inverter continues to carry hazardous voltages for up to 5 minutes after it was switched off.

The frequency inverter continues to carry hazardous voltages for up to 5 minutes after it was switched off. Getriebebau NORD GmbH & Co. KG Getriebebau-Nord-Straße 1 22941 Bargteheide, Germany www.nord.com o SK BRI4-1-200-100 Part number: 275 272 008 Internal braking resistor for connection to a NORDAC FLEX SK

More information

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions DT1100 E xx xx (PS) Galvanic Isolators Operating Instructions Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized

More information

Level Switch NRS 2-50 NRS Original Installation Instructions English

Level Switch NRS 2-50 NRS Original Installation Instructions English Level Switch NRS 2-50 NRS 2-51 EN English Original Installation Instructions 819179-03 1 Contents Important Notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and Standards

More information

PHV RO High Voltage Passive Probe. Instruction Manual

PHV RO High Voltage Passive Probe. Instruction Manual PHV 1000-3-RO High Voltage Passive Probe Instruction Manual Copyright 2012 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

Commissioning and Maintenance of Power Factor Correction Systems

Commissioning and Maintenance of Power Factor Correction Systems Dear Customer, We would like to thank you for choosing a power factor correction system from FRAKO Kondensatoren- und Anlagenbau GmbH. It is a pleasure to welcome you into the ever-expanding circle of

More information

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

PHV 1000-RO High Voltage Passive Probe. Instruction Manual PHV 1000-RO High Voltage Passive Probe Instruction Manual Copyright 2014 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

Gate control mts2000/02 R2.8

Gate control mts2000/02 R2.8 Control system Gate control mts2000/02 R2.8 I Table of contents 1 Conformities 1.1 Guidelines and standards 1-1 1.2 CE mark 1-1 2 General safety information 2.1 Explanation of symbols used to provide safety

More information

Operating manual. Force transducer with strain gage measuring system C9B. A en. hvordan man bruger astrologi med tibetanske medicin

Operating manual. Force transducer with strain gage measuring system C9B. A en. hvordan man bruger astrologi med tibetanske medicin Operating manual Force transducer with strain gage measuring system C9B hvordan man bruger astrologi med tibetanske medicin C9B Contents 3 Page Safety instructions..............................................

More information

IQ SENSOR NET MIQ/MC(-A)-RS

IQ SENSOR NET MIQ/MC(-A)-RS ESC OK! OK Operating Manual IQ SENSOR NET MIQ/MC(-A)-RS Power C M S Modem Radio Remote connection to the IQ SENSOR NET System 2020 XT via - fixed line telephone network - mobile network - radio link ba64121e03

More information

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4 SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: 16.10 Document Number: KUCSH0039 Rev: 4 16.10.1 INTRODUCTION 16.10.1.1 The intent of this standard is to ensure that continuity

More information

GESTRA Steam Systems LRS English. Installation & Operating Instructions Conductivity Switch LRS 1-50

GESTRA Steam Systems LRS English. Installation & Operating Instructions Conductivity Switch LRS 1-50 GESTRA Steam Systems LRS 1-50 EN English Installation & Operating Instructions 819223-02 Conductivity Switch LRS 1-50 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety

More information

Assembly. Front view. Switch Power Rail

Assembly. Front view. Switch Power Rail Switch Amplifier Features Assembly 1-channel isolated barrier 24 V DC supply (Power Rail) Dry contact or NAMUR input 2 passive transistor outputs (resistive acc. to EN 60947-5-6) Line fault transparency

More information

ACK. Menue. Channel 1 Alarm Channel 2 Ch 2. Outputs. Filter constant. Output: Current limit 0.11 A ± 10 % Int. voltage drop 2.5 V at max.

ACK. Menue. Channel 1 Alarm Channel 2 Ch 2. Outputs. Filter constant. Output: Current limit 0.11 A ± 10 % Int. voltage drop 2.5 V at max. 62 100 2-fold analogue Limit Monitor 62 100 safety-related Input 0...22 m / 0...5.5 V without line diagnosis or 4...22 m / 1...5.5 V with line diagnosis 2 outputs 100 m each with parameterizable line diagnosis

More information

Installation Instructions RF-identification system Read/write head ANT513

Installation Instructions RF-identification system Read/write head ANT513 Installation Instructions RF-identification system Read/write head ANT513 80262946 / 00 04 / 2017 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 2.1 General...4 2.2 Radio

More information

Mounting Guide ThermoControl 3

Mounting Guide ThermoControl 3 Mounting Guide ThermoControl 3 Warning! Before beginning any work, read this mounting guide and any associated installation guides. Before starting up the device, make sure that it is free from defects

More information

Industrial motor controller for brushed DC motors 24 VDC

Industrial motor controller for brushed DC motors 24 VDC Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 5 A Control with the following functions: - reversal of direction of rotation - open-loop speed control (external)

More information

Instruction Manual MSC710 MSC710-U MSC710-I

Instruction Manual MSC710 MSC710-U MSC710-I Instruction Manual MSC710 MSC710-U MSC710-I Sensor controller for inductive displacement and gauging sensors series LVDT MICRO-EPSILON MESSTECHNIK GmbH & Co. KG Koenigbacher Strasse 15 94496 Ortenburg

More information

Radio receiver FS20 EAM

Radio receiver FS20 EAM OPERATING INSTRUCTIONS Version 12/06 Radio receiver FS20 EAM (for FS20 DIN rail system) Item no. 62 30 12 Introduction Dear customer, Thank you for purchasing this product. This product meets the requirements

More information

Operating Instructions

Operating Instructions Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description

More information

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space Wireless wall transmitter, 1-gang with inscription space Order No. : 5331.. Wireless wall Order No. : 5333.. Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected

More information

Signal converter for electromagnetic flowmeters

Signal converter for electromagnetic flowmeters Quick Start Signal converter for electromagnetic flowmeters Electronic revision: ER 3.0.xx The documentation is only complete when used in combination with the relevant documentation for the flow sensor.

More information

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems 3 041 RCU10 RCU101 Room Temperature Controllers for heating and cooling systems RCU10 Choice of two-position or modulating PI control ON / OFF or PWM outputs for heating and cooling Operating modes: normal

More information

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany Technical manual Microstep driver NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D-85652 Landsham near Munich, Germany Tel. +49 (0)89-900 686-0 Fax +49 (0)89-900 686-50 info@nanotec.de Editorial Editorial

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Digital Multimeter E 1018832 Instruction sheet 12/16 SD/UD 1 probe 1a Finger guards 2 Measurement socket 10 A for current measurement in 10-A (positive) 3 Measurement socket COM (negative)

More information