Radio receiver E17 2-channel, 27 MHz, 40MHz, or 433 MHz, 2 relay outputs. Operating voltage: 230 V/AC or 12 V or 24 V AC/DC available.

Size: px
Start display at page:

Download "Radio receiver E17 2-channel, 27 MHz, 40MHz, or 433 MHz, 2 relay outputs. Operating voltage: 230 V/AC or 12 V or 24 V AC/DC available."

Transcription

1 Fig.: 230 V version Radio receiver E17 2-channel, 27 MHz, 40MHz, or 433 MHz, 2 relay outputs. Operating voltage: 230 V/AC or 12 V or 24 V AC/DC available. Installation, connection and programming instructions for the installer. Keep these instructions safe for later reference. Read these instructions before starting to use the system!

2 Safety instructions 2 Failure to observe these safety instructions can lead to personal injury and damage to equipment! Assembly, installation, commissioning and maintenance Specialist requirements These instructions presuppose specialist knowledge conforming to at least one of the following trades: - Electrical installer - Electrical system fitter - Electrical machinery fitter - Electrical technician - Industrial electrician or electrical technician in accordance with German accident prevention regulations BGV A2 (VBG 4). When working on the receiver: - Switch off the power supply voltage - Check all connections again before switching the power back on. - The system will only work reliably if carefully assembled in accordance with these instructions. - No technical modifications may be carried out by the user. Any modifications will invalidate the liability and guarantee conditions. Important operating instructions: - This remote control may only be used for devices and systems in which a fault in the transmitter or receiver does not create any danger to persons or equipment, or in which such a risk is covered by other safety devices. - This remote control may not be used for equipment and systems with an increased accident risk (e.g. crane systems)! - Observe the applicable local regulations. - Observe the accident prevention, VDE and EVU regulations. - Information is available from the VDE and relevant trade associations. Installation instructions: Failure to observe these safety instructions can lead to personal injury and damage to equipment! In order to avoid damage to the receiver: - Protect the receiver from the effects of weather. - Install only in the housing and on a level undersurface. - Install vertically, feeding lines in from the bottom or from the side, in order to prevent the ingress of water. - Open the cable apertures carefully using a round screwdriver or similar, in order to prevent leaks. Storage and transport conditions Failure to observe these instructions can lead to failure, even after commissioning! Store in a dry, dust-free area protected against shocks and impacts. Storage temperature -20 C C at 30 %...60 % rel. air humidity. Transport only with adequate and well-padded extra packaging. - The existing packaging is not intended as transport packaging. - Damage caused by failure to observe these instructions is not covered by the guarantee!

3 3 Functional description Area of application With 2 potential-free, high-load relays (1xUM) in the output, the E17 offers a wide range of application possibilities. The receiver is particularly suitable for the activation of lighting, alarm systems, garden fountains etc. An automatic switch-off- time can be set for every output. By means of a radio signal, the outputs can be switched off prematurely or the switch-off delay can be started again from the beginning. Suitable for use as a stairwell time switch with the possibility of reactivation Functions 2-channel version with 27 MHz, 40 MHz, 433 MHz or 868 MHz Frequency conversion by means of replaceable radio modules Operating modes: Impulse, surge, ON/OFF, Auto-Off adjustable from 1 second to approx. 18 hours 2 relay-outputs, each 1xUM, potential-free Sockets & displays Power LED (green) Lights up when power supply is on, flashes when deleting. Auto-Off switches (1= channel 1, 2= channel 2) The DIP switches are used for teaching-in the Auto-Off times (Page 4). OUT LEDs K1/K2 (yellow) -Flash when teaching-in new transmitters. -Light up when the corresponding channel is activated (relay on). -Flash when deleting, or when the radio signal of a taught-in transmitter is being received. SET switches K1/K2 For teaching-in and deleting transmitters or (Page 4) Radio module socket (shown with module fitted) For description, see Page 6. Antenna Connection for the transmission antenna. Connection terminals Power supply and relay outputs (for connection, se Page 5).

4 Programming 4 A maximum of 60 transmitters can be taught-in. If 60 transmitters have already been taught-in to the receiver, no further transmitters will be accepted, and the codes already learnt will not be lost. The first transmitter taught-in determines which coding scheme will be valid. Only 12-bit, 18-bit or Keeloq transmitters can be taught-in. This means that if the first coding learnt was for example 18-bit, then only transmitters with 18-bit coding can be taught-in. Another coding can be taught-in after first deleting all existing transmitters. Every transmitter switch can be set for different operating modes on both channels. For instance, any switch can control the Off or On function for both channels. Operating modes Impulse: The output is activated as long as the selected transmitter switch is actuated. Surge: The condition of the output changes with every actuation of the transmitter switch. On/Off: One transmitter switch is allocated the On or Off function. Teaching-in transmitter switches Mode Programming OUT LED display Impulse Surge On Off Press SET switch 1 x briefly Actuate the transmitter switch for 3 s. Press SET switch 2 x briefly Actuate the transmitter switch for 3 s. Press SET switch 3 x briefly Actuate the transmitter switch for 3 s. Press SET switch 4 x briefly Actuate the transmitter switch for 3 s. flashes 1 x -Pause- flashes 1x... flickers* flashes 2 x -Pause- flashes 1x... flickers* flashes 3 x -Pause- flashes 1x... flickers* flashes 4 x -Pause- flashes 1x... flickers* * When a radio signal is detected, the OUT LED flickers, and the transmitter switch has now been taught-in. An asymmetrical coding must be set for transmitters with a coding switch! Setting all coding switches to ON or OFF will lead to a loss of function or incorrect function!! Teaching-in/deleting Auto-Off times The Auto-Off time for each channel is set separately using the DIP switches 1+2 (see Page 3, Pos. 2). Setting the DIP switches to the starting position deactivates the function. - For Auto-Off, the operating modes Surge or ON must be taught-in. Example: Channel 1 is to be set to switch off after 3 minutes. DIP switch1 must be in the lower position. Switch on channel 1 by radio. After 3 minutes, set DIP switch 1 to ON and leave it in this position. The channel switches off, and the Auto-Off time has now been taught-in. In the operating mode ON, the time can be reset by actuating the switch again. The channel can be switched off prematurely with Impulse, Surge and OFF. The time can be learnt in increments of 1 second, from 1 second to approx. 18 hours. Deleting codes Actuate a SET switch until the OUT LEDs switch from flashing to Off. All the taught-in codes will be deleted! Individual codes cannot be deleted separately.

5 5 Connection Wiring diagram E17 Switch Auto-Off ON 12 SET K1 SET K2 Relay 1xUM Channel 1 Operating voltage Power supply unit depending on version!see type designation plate + ~ NC 5 ~ 6 - LED K1 yellow Power supply unit RL1 POWER LED green Radio switch evaluation Relay 1xUM Channel LED K2 yellow RL2 Antenna. Connecting operating voltage The power supply must be connected as shown in the table, and in accordance with local regulations, such as VDE, EVU etc. Connection terminals (see Page 3 for connection) Relay output K Operating voltage to type designation plate Relay output K2 Connecting outputs Various consumers can be connected to the terminals (channel 1) and (channel 2) (see Technical data, Page 7). Connecting the antenna - Connect the antenna and feed it out of the housing through an empty aperture (see Pos. 6, Page 3). - Do not lay the antenna along pipes, metallic objects or lighting systems! - Do not attach the end of the antenna to metallic objects. - In order to achieve the maximum range, the whole length of the antenna must be laid out (i.e. not shortened or coiled). - Do not connect an external antenna by means of coaxial cable.

6 Replacing the radio module 6 In order to avoid damage due to electrical discharging, you must earth yourself before installing the module (e.g. by touching a water pipe or radiator).! The following radio modules can be used: HAM27-51 = 27,015 MHz AM HAM40-51 = 40,685 MHz AM HFM40-51 = 40,685 MHz FM HQAM = 433,920 MHz AM HQAM = 868,300 MHz AM Replacing the radio module (Frequency change) If interference occurs in the frequency band being used, the receiver can be converted to another frequency by replacing the radio module. The transmitter and the radio module must have the same frequency and the same modulation procedure e.g. AM or FM. - Switch off the supply voltage! - Disconnect the radio module carefully from the connection socket Pos. 5 (see Page 3). - Connect a radio module with the required frequency. - Switch on the supply voltage. - Delete the radio (see Page 4). - Teach-in new transmitters. Radio module installation. The installation is carried out in the same way for all modules.

7 7 Technical data Technical data Frequency: Coding: Operating voltage: see type designation plate Power consumption: at 230 V/AC Current consumption: at 12/24 V AC/DC Output: Operating temperature: Dimensions: Weight: - Optional radio modules with 27 MHz, 40 MHZ, 433 MHz or 868 MHz are available (see Page 6) bit, 18-bit or Keeloq, self-learning, max. 60 codes (transmitters switch) can be taught-in - Depending on version: 230 V, ± 10 % 50 Hz or 12 V (11 V...18 V AC/DC) or 24V (20 V...28 V AC/DC) - approx. 2 VA VA (no outputs/all outputs switched on) - approx. 15 ma 60 ma (no outputs/all outputs switched on) - 2-relay, each 1xUM, potential-free, 250 V/AC, max. 500 VA, ohmic load per output C C at 30 %...80 % rel. air humidity - approx. 80 mm x 80 mm x 52 mm, Housing plastic IP65 (dimensions without attachment flanges) - approx. 170 g incl. packaging Identifying the version The following type designation plate serves as an example only. The actual data can be found on the type designation plate attached to the outside of the receiver housing. The power supply connected must match that specified on the type designation plate. Order no: E17-40A = Basic type 2 = Frequency AM/FM 3 = Version Operating voltage: e. g. 230 V/AC 12 V AC/DC 24 V AC/DC Frequency/Modulation: e. g. 27,015MHz 40,685MHz 433,92MHz 868,30MHz 2K Funkempfänger 0074 E17-40A V AC/DC (11V...18V AC/DC) 40,685 MHz AM R IP65 Sample type designation plate

8 Fault-finding 8 Fault-finding Fault Possible cause Remedy Power LED - No operating voltage - Check connection fails to come on or +/- terminals reversed (DC) Relay not switching - Transmitter not taught-in - Teach-in transmitter LED on transmitter - Frequency from transmitter and - Use correct transmitter and Power LED receiver not identical still come on - Transmitter switch not actuated - Actuate switch for at least for long enough seconds - Transmitter defective - Check transmitter and replace if necessary - Receiver defective - Check receiver and replace if necessary Inadequate range - Battery in manual transmitter - Check battery too weak and replace if necessary - Antenna not connected - Maintain proper distance or incorrectly laid from steel equipment and electrical leads Disposal The controls do not contain any materials subject to special disposal regulations at the time of compilation of these instructions. The controls do not contain any built-in energy sources. Subject to technical amendment. Date: _EN GL

Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions)

Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions) EN Wireless Receiver E28Q Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions) Always read before initial operation! 28509900_E28Q_EN_2012-05-08.doc 1 / 12 1 Data

More information

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Gain Electronic Co. Ltd. Table Of Contents Safety Considerations ------------------------------------------------------------2

More information

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description RAD-IN/OUT-D Digital extension modules for the bidirectional wireless system INTERFACE Data sheet 102122_en_0 PHOENIX CONTACT 2010-02-2 1 Description The RAD-ISM-...-SET-BD-BUS-ANT bidirectional wireless

More information

Receiver Type /Version Factory No. Frequency. Transmitter Type /Version Factory No. Frequency

Receiver Type /Version Factory No. Frequency. Transmitter Type /Version Factory No. Frequency Receiver Type /Version Factory No. Frequency Transmitter Type /Version Factory No. Frequency 1. STANDARD SPECIFICATION Portable transmitter. Receiver with integrated mounting holes. Multi-pin connecting

More information

Awning control system GFM001. Installation and Operating Instructions

Awning control system GFM001. Installation and Operating Instructions Geiger-Funk Sunshade controls Awning control system for 230V drives GFM001 Installation and Operating Instructions for pre-coded systems Table of Contents 1 Introduction...3 2 Safety instructions...3 3

More information

Wireless Room Thermostat Installation and Operation Y6630D1007

Wireless Room Thermostat Installation and Operation Y6630D1007 Wireless Room Thermostat Installation and Operation Y6630D1007 General safety instructions Contents 1. General safety instructions... 3 1.1. Commissioning the relay module HC60NG... 3 2. Overview... 4

More information

P700-WLS ioprox Receiver

P700-WLS ioprox Receiver Installation Manual DN1628-1611 Pre-Installation Notes Copyright 2016 Tyco International Ltd. and its Respective Companies. All Rights Reserved. All specifications were current as of publication date and

More information

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK Mounting instruction and operating manual Access Point (UK) HmIP-HAP-UK Package contents Quantity Description 1 Homematic IP Access Point (UK) 1 Plug-in mains adapter 1 Network cable 2 Screws 2 Plugs 1

More information

Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity

Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity Documentation Measurement and Control Type: ELT-GP1 Content 1. Installation instructions 2. Data sheets 3. Declarations of conformity (Part No. 008Q520) eltherm GmbH Ernst-Heinkel-Str. 6-10 57299 Burbach

More information

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional B-Tronic EasyControl EC5401B en Assembly and Operating Instructions Wall/hand-held transmitter, 1-channel, bidirectional Important information for: Fitters / Electricians / Users Please forward accordingly!

More information

VIESMANN. Installation and service instructions VITOTROL 300 RF. for contractors. Vitotrol 300 RF

VIESMANN. Installation and service instructions VITOTROL 300 RF. for contractors. Vitotrol 300 RF Installation and service instructions for contractors VIESMANN Vitotrol 3 RF Wireless remote control for one, two or three heating circuits For applicability, see the last page VITOTROL 3 RF 4/212 Please

More information

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Original operating instructions Fail-safe inductive sensor GG507S / / 2013 Original operating instructions Fail-safe inductive sensor GG507S 80005283 / 00 05 / 2013 Contents 1 Preliminary note...3 1.1 Explanation of symbols...3 2 Safety instructions...4 2.1 Safety-related requirements

More information

RADIOBAND V3 Programming & Installation Manual

RADIOBAND V3 Programming & Installation Manual RADIOBAND V3 Programming & Installation Manual Radioband V3 User s Manual Introduction The RadioBand system is designed for Automatic Gates, Commercial and Domestic door applications where a safety edge

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

COD GB / 1.0 RBAND/UMS - RBAND/CSM

COD GB / 1.0 RBAND/UMS - RBAND/CSM INTRODUCTION DESCRIPTION The RadioBand system is designed of Industrial, Commercial and Domestic door and gate applications where a safety edge is used. The system provides a wireless system replacing

More information

Radio receivers type DB317 and DBR1-M4

Radio receivers type DB317 and DBR1-M4 Radio receivers type DB317 and DBR1-M4 User manual Art no 006176 Technical data DB317 DBR1-M4 Dimensions (WxHxD) 45x75x21 mm 80x80x50 mm Supply Voltage via control panel 12/24 VAC/VDC Current Consumption

More information

1 Safety instructions. 2 Device components. 3 Function. Radio Management Repeater. Operationsmanual

1 Safety instructions. 2 Device components. 3 Function. Radio Management Repeater. Operationsmanual Art.-No.: 100 FR Operationsmanual 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage to the

More information

Transmitter System USER S MANUAL. Light Series

Transmitter System USER S MANUAL. Light Series Transmitter System USER S MANUAL Light Series Follow the indications and warnings given by the machine producer regarding the machine controlled by the radio remote control. The information contained in

More information

WLS-5500 Receiver (KSF & W26)

WLS-5500 Receiver (KSF & W26) WLS-5500 Receiver (KSF & W26) Installation Manual DN1869-0912 Warning! This manual contains information on limitations regarding product use and function and information on the limitations as to liability

More information

Installation and Operating Instructions for Phase Demodulator Type _.2

Installation and Operating Instructions for Phase Demodulator Type _.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/EU and the Electromagnetic Compatibility (EMC)

More information

Radio receiver FS20 EAM

Radio receiver FS20 EAM OPERATING INSTRUCTIONS Version 12/06 Radio receiver FS20 EAM (for FS20 DIN rail system) Item no. 62 30 12 Introduction Dear customer, Thank you for purchasing this product. This product meets the requirements

More information

Installation / Monitoring Technique

Installation / Monitoring Technique Installation / Monitoring Technique VARIMETER RCM Residual Current Monitor, Type B for AC and DC Systems IP 5883 0249633 IP 5883 ND 5018/035 ND 5018/030 According to IEC/EN 62 020, VDE 0663 For AC and

More information

Operating instructions Fail-safe delay timer AZS About this document. Content

Operating instructions Fail-safe delay timer AZS About this document. Content 8 Appendix 8.1 Wiring example...4 8.2 Integral System Diagnostics (ISD)....5 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101126753-

More information

Modular Radio Telemetry System

Modular Radio Telemetry System Simple to Use Remote Control 8 Channels per Transmitter 16 Channels per Receiver Upto 48 Transmitters per system Auto Transmit Mode Secure RF Protocol Automatic Watchdog Transmission Range: Upto 200 metres

More information

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space Wireless wall transmitter, 1-gang with inscription space Order No. : 5331.. Wireless wall Order No. : 5333.. Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected

More information

1 Safety instructions. 2 Device components. Radio bus system. Radio socket outlet adapter for dimming Order No. : Operating instructions

1 Safety instructions. 2 Device components. Radio bus system. Radio socket outlet adapter for dimming Order No. : Operating instructions Order No. : 1185.. Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible.

More information

Installation Instructions RF identification system Read/write head ANT430 ANT431

Installation Instructions RF identification system Read/write head ANT430 ANT431 Installation Instructions RF identification system Read/write head ANT430 ANT431 UK 80262949 / 00 04 / 2017 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 2.1 General...4

More information

Gate control mts2000/02 R2.8

Gate control mts2000/02 R2.8 Control system Gate control mts2000/02 R2.8 I Table of contents 1 Conformities 1.1 Guidelines and standards 1-1 1.2 CE mark 1-1 2 General safety information 2.1 Explanation of symbols used to provide safety

More information

Copyright Graupner/SJ GmbH. Manual. mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031

Copyright Graupner/SJ GmbH. Manual. mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031 Copyright Graupner/SJ GmbH EN Manual mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031 Index Introduction... 4 Service Centre... 4 Intended use... 5 Package content... 5 Technical Data... 5 Symbols Explication...

More information

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300 Monitoring Technique VARIMETER IMD Insulation monitor RN 5897/300 0274214 Your Advantages For mobile generator sets according to DIN VDE 0100-551 Preventive fire and system protection Detection of symmetric

More information

User Manual March 2008

User Manual March 2008 User Manual March 008 Motor Silent Gliss 900, 90, 90, 903 Motor Silent Gliss 9030, 903, 903, 9033 Usermanual Motors 90x_903x Page Copyright April 007 by Silent Gliss International Ltd., 3073 Gümligen/Berne

More information

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5.

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5. Content Monitoring relay pluggable 1-phase current monitoring relay... 5.2 1-phase direct-current voltage monitoring relay... 5.6 1-phase voltage monitoring relay... 5.10 3-phase voltage monitoring relay...

More information

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch Radio Touch Order no.: 2880 xx Operation and installation instructions 1 Safety instructions Electrical equipment must only be installed and assembled by a qualified electrician in accordance with the

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Digital Multimeter E 1018832 Instruction sheet 12/16 SD/UD 1 probe 1a Finger guards 2 Measurement socket 10 A for current measurement in 10-A (positive) 3 Measurement socket COM (negative)

More information

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions Order-No. : 1135 00 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage

More information

Radio Control Installation and Operating Instructions System 4

Radio Control Installation and Operating Instructions System 4 Radio Control Installation and Operating Instructions System 4 P.O. Box 403, One Cedar Parkway, Jackson, WI 53037 Phone: 800-628-1909 Fax: 262-677-2058 Revision: April 19, 2012 Contents Introduction 3

More information

Commissioning and Maintenance of Power Factor Correction Systems

Commissioning and Maintenance of Power Factor Correction Systems Dear Customer, We would like to thank you for choosing a power factor correction system from FRAKO Kondensatoren- und Anlagenbau GmbH. It is a pleasure to welcome you into the ever-expanding circle of

More information

CONTENTS XV300K GB r doc XV300K 2/13

CONTENTS XV300K GB r doc XV300K 2/13 XV300K CONTENTS 1 PRELIMINARY CHECK GUARANTEE RECYCLING... 3 2 XV300K SPECIFICATIONS OF USE... 3 3 CODES - MODELS... 4 4 TECHNICAL SPECIFICATIONS... 4 5 STANDARD REFERENCES... 5 6 MECHANICAL INSTALLATION...

More information

Wireless multizone receiver RDE-MZ6

Wireless multizone receiver RDE-MZ6 s 1 428 Wireless multizone receiver RDE-MZ6 for floor heating / zone heating systems Mains-powered RDE-MZ6 multizone wireless receiver (AC 230 V) DIN rail mounting 2-position control with On/Off output

More information

Copyright Graupner/SJ GmbH. Manual. mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031

Copyright Graupner/SJ GmbH. Manual. mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031 Copyright Graupner/SJ GmbH EN Manual mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031 Index Introduction... 4 Service Centre... 4 Intended use... 5 Package content... 5 Technical Data... 5 Symbols explication...

More information

Control solutions Biofloor

Control solutions Biofloor MR24 Central radio controller 24V Connect COMAP offers the Connect control system as part of its underfloor heating and cooling solution. Composed of a central radio control module (MR24), wireless digital

More information

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx KNX radio wall-transmitter 1gang/2gang flat quicklink KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx KNX radio wall-transmitter 1gang/2gang flat solar quicklink Order no.:

More information

9RCT4334 Four Button. 2 3/4 X 1 3/8 X 9/16 (70mm x 35mm x 14mm) 2 3/4 x 2 1/8 x 1 (70mm x 55mm x 25mm)

9RCT4334 Four Button. 2 3/4 X 1 3/8 X 9/16 (70mm x 35mm x 14mm) 2 3/4 x 2 1/8 x 1 (70mm x 55mm x 25mm) INSTALLATI 9RCR433/9RCT433 433MHz Transmitters & Receiver Description The 433MHz Series Transmitters and Receiver are ideal for the wireless activation and/or sequencing of automatic doors and remote access

More information

CM-IWM.11 Insulation monitoring relay

CM-IWM.11 Insulation monitoring relay Data sheet CM-IWM.11 Insulation monitoring relay The insulation monitor CM-IWM.11 provides best and up to date insulation monitoring of modern IT systems in an optimum and state of the art way fulfilling

More information

Technical Documentation

Technical Documentation Technical Documentation PROAM-21 Power amplifier for directional valves Grundlage der Funktionsbeschreibung und zur Prüfung der Module (keine Produktdokumentation). AMCA HYDRAULIC FLUID POWER B.V. P.O.BOX

More information

PRO Professional Radio Control Series Applications

PRO Professional Radio Control Series Applications 204 205 Ready to Use Remote Control 4, 8/16 Channel Systems Range: Up to 200 metres at 433MHz Up to 1,000 metres at 433MHz NB Relay Outputs: Momentary, Latching, Timed Receiver IP65 Applications Lighting

More information

Radio Remote Controls Manual K Series

Radio Remote Controls Manual K Series Radio Remote Controls Manual K Series PN 52764 2010.12.20 Rev. 2 K Series radio control manual 1 Conductix Incorporated The technical data and images which appear in this manual are for informational purposes

More information

Modular Radio Telemetry System

Modular Radio Telemetry System Simple to Use Remote Control 8 Channels per Transmitter 16 Channels per Receiver Upto 48 Transmitters per system Auto Transmit Mode Secure RF Protocol Automatic Watchdog Transmission Range: Upto 200 metres

More information

English RACON SERIES II RADIO CONTROL SERVICE MANUAL

English RACON SERIES II RADIO CONTROL SERVICE MANUAL English 22.2.2007 RACON SERIES II RADIO CONTROL SERVICE MANUAL Read the instructions supplied with the product before installation and commissioning. Keep the instructions in a safe place for future reference.

More information

Data sheet. Function description. Benefits

Data sheet. Function description. Benefits uminaire-integrated modules SESOTEC MB Sensor Modules 110042808 SESOTEC MB HF1 COM1 110051733 SESOTEC MB HF1 DAI 110059684 SESOTEC MB HF2 COM1 Function description With the new HF sensor modules, you,

More information

FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470

FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470 FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470 WARRANTY INMOTION Controls, Inc. guarantees that this product meets its published specification at the time of shipment from the factory. Under proper installation,

More information

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Installation and Operational Instructions for ROBA -switch Type 017._00.2 OBA -switch Type 017._00.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EC Low Voltage Directive 2014/35/ EC and the EMC Directive

More information

Radio System Strobe Wizard Plus Freemask

Radio System Strobe Wizard Plus Freemask Radio System Strobe Wizard Plus Freemask User manual Translation of the original German user manual Doc. No.: 900.0509.00 Version: 09/2017 Contents Information about this manual and about the manufacturer...

More information

RadioStar INTRODUCTION

RadioStar INTRODUCTION CONTENTS INTRODUCTION...2 PACK CONTENTS...2 SAFETY INSTRUCTIONS...3 DEFINITION OF SYMBOLS...4 RECOMMENDED TOOLS...4 ASSEMBLY INSTRUCTIONS...5 RADIOSTAR MIRROR FUNCTIONS...7 SIDE INTEGRATED CONTROL PANEL...8

More information

Coin control unit. Operating instructions C 4065

Coin control unit. Operating instructions C 4065 Operating instructions Coin control unit C 4065 G To avoid the risk of accidents or damage to the machine it is essential to read these instructions before installing, commissioning and using it for the

More information

RF Remote Control Unit SEAV

RF Remote Control Unit SEAV RF Remote Control Unit SEAV for LINAK TECH-systems Installation instructions Foreword Dear producer, Thank you for choosing an actuator system from LINAK. LINAK systems consist of high-tech products based

More information

Series 1. Remote. Multiple Mode Remote Controlled Electro Stimulation Control Unit. User Manual

Series 1. Remote. Multiple Mode Remote Controlled Electro Stimulation Control Unit. User Manual Series 1 Remote Multiple Mode Remote Controlled Electro Stimulation Control Unit User Manual Issue 5.0 March 2010 WELCOME 4 2 Key Features 4 WHAT'S IN THE KIT? 5 Contents 5 Quick Guide 5 Before Use 5 USING

More information

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information *09005137* BA_EN_DE50 Rev.A 11/12 *09005137* d e v e l o p i n g s o l u t i o n s DE50 Operating Manual Differential pressure transmitter Table of Contents 1 Safety guidelines 2 Application purpose 3

More information

QUINT-PS/ 3AC/24DC/10

QUINT-PS/ 3AC/24DC/10 Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 Description PHOENIX CONTACT - 09/2009 Features QUINT POWER power supply units Maximum system

More information

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2 for Low Voltage, and EMC Directives. Approved by UL and CSA. Lloyds/NK approvals.

More information

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/ EU and the Electromagnetic Compatibility (EMC)

More information

Operating instruction

Operating instruction Operating instruction Radio Ref. no.: RAN..514.. RAN..914.. Table of contents 1. Safety notes... 3 2. Device overview... 4 2.1.Operating elements... 4 3. Function... 5 3.1.Intended use... 5 3.2.Product

More information

R PROFLAME Instruction Book Collection

R PROFLAME Instruction Book Collection 9.956.028 R00 584 PROFLAME Instruction Book Collection 4-17 18-29 584 PROFLAME System 30-39 Appendix: DIP SWITCH NUMBER (0=ON 1=OFF) 40-41 4-17 Fig. 1 The SIT is a device that allows, in conjunction with

More information

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2. Conforms to EMC standards (EN50081-2 and EN50082-2). Approved by UL and CSA. Lloyds/NK

More information

Original operating instructions Fail-safe inductive sensor GG507S

Original operating instructions Fail-safe inductive sensor GG507S Original operating instructions Fail-safe inductive sensor GG507S 80236827 / 00 09 / 2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety instructions...4 2.1 Safety-related

More information

BOX V2.1 INSTALLATION INSTRUCTIONS

BOX V2.1 INSTALLATION INSTRUCTIONS BOX V2.1 INSTALLATION INSTRUCTIONS Photo non contractuelle Juin 2010 Code : 17.1983.0001. Ind : 01 FR 5 6 7 8 9 10 4 11 3 12 2 13 1 14 15 20 19 18 17 16 Bill of materials 1. Supply removable terminals

More information

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103383_en_00 1 Description PHOENIX CONTACT - 06/2008 Features QUINT POWER power supply units highest system

More information

Operating Instructions. Combination sensor

Operating Instructions. Combination sensor Operating Instructions 1. Safety warnings Attention: Electrical equipment must be installed and fitted by qualified electricians only and in strict observance of the relevant accident prevention regulations.

More information

Operating instructions Electronic level sensor LK / / 2008

Operating instructions Electronic level sensor LK / / 2008 Operating instructions Electronic level sensor LK31 UK 704046 / 00 01 / 2008 Contents Safety instructions...2 Menu structure...3 Controls and indicating elements...4 Function and features...5 Functional

More information

B-Tronic EasyControl EC5401B

B-Tronic EasyControl EC5401B B-Tronic EasyControl EC5401B en Assembly and Operating Instructions Wall/hand-held transmitter, 1-channel, bidirectional Important information for: Fitters / Electricians / Users Please forward accordingly!

More information

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock MAIN FEATURES: MAIN UNIT GB MODEL: RMR182 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RMR182 Multi- Channel In-Out

More information

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual

More information

DZD 92 L. Wiring diagram. Time domains. Function. Dimensional drawing. Indicators. Accessories

DZD 92 L. Wiring diagram. Time domains. Function. Dimensional drawing. Indicators. Accessories DZD 92 L Multi-Function - Multi-domain time relay Mono voltage 8 Functions Setting range 0.05 s to 100 h subdivided into 7 time domains 1 immediate-action and 1 time contact or 2 time contacts (adjustable)

More information

ENGLISH PORTUGUÊS NEDERLANDS DAB200

ENGLISH PORTUGUÊS NEDERLANDS DAB200 DEUTSCH ENGLISH FRANÇAIS NEDERLANDS ESPAÑOL PORTUGUÊS NORSK DAB200 Contents Introduction..... 2 What is DAB + Digital Radio?.... 2 Setting up..... 3 Backlit display.... 4 Using headphones...... 4 Your

More information

PROFLY / PROBLADE Professional Radio Control PRO-BLADE8

PROFLY / PROBLADE Professional Radio Control PRO-BLADE8 PRO-BLADE8 Ready to Use Remote Control 8 Channel Systems Range: PROFLY Up to 100 metres PROBLADE Up to 500 metres Relay Outputs: Momentary, Latching, Timed Receiver IP65 Applications Lighting Control General

More information

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay Overcurrent Protection / 7SJ46 SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay Function overview Fig. /11 Description The SIPROTEC easy 7SJ46 is a numerical overcurrent protection relay which

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D Herxheim Tel. (07276) FAX 6978

WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D Herxheim Tel. (07276) FAX 6978 2m DISCOVERY LINEAR AMPLIFIER (GS 31) Operating Manual WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D-76863 Herxheim Tel. (07276) 96680 FAX 6978 http://www.wimo.com e-mail: info@wimo.com INDEX 1. Specifications

More information

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Original operating instructions Fail-safe inductive sensor GM504S / / 2010 Original operating instructions Fail-safe inductive sensor GM504S 704070 / 01 06 / 2010 Contents 1 Preliminary note 3 1.1 Explanation of symbols 3 2 Safety instructions 4 2.1 Safety-related requirements

More information

AC 3. Active Antenna Combiner. Instruction manual

AC 3. Active Antenna Combiner. Instruction manual AC 3 Active Antenna Combiner Instruction manual Contents Contents Important safety instructions... 2 The AC 3 active transmitter combiner... 4 Delivery includes... 4 Operating controls... 5 Block diagram...

More information

Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator

Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator Operating Instructions 3-349-298-15 3/11.09 METRAVOLT 7A Voltage Tester per IEC 61243-3 with Phase and Polarity Tester and Phase Sequence Indicator CAT IV GMC-I Messtechnik GmbH Südwestpark 15 90449 Nürnberg

More information

REMOTE CONTROL EXTENDER MODEL IR-320 CHO4009 OWNERS MANUAL R1848

REMOTE CONTROL EXTENDER MODEL IR-320 CHO4009 OWNERS MANUAL R1848 REMOTE CONTROL EXTENDER MODEL IR-320 CHO4009 OWNERS MANUAL R1848 LOCATION OF CONTROLS Transmitter Side Receiver Side DC Power IR Probe DC Power Transmitter and Receiver Front Infrared Remote Control Antenna

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Analogue Multimeter Escola 100 1013527 Instruction sheet 12/15 SD/JS 1 Display with mirror scale 2 Slotted screw for zero calibration 3 Calibration trimmer for setting centre zero

More information

Installation Instructions RF-identification system Read/write head ANT513

Installation Instructions RF-identification system Read/write head ANT513 Installation Instructions RF-identification system Read/write head ANT513 80262946 / 00 04 / 2017 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 2.1 General...4 2.2 Radio

More information

Thyristor power controller B DI1002 V1.0 Manual/Operating instructions

Thyristor power controller B DI1002 V1.0 Manual/Operating instructions 1 B DI1002 V1.0 Manual/Operating instructions 2 1 Introduction Before you put the thyristor controller into operation, please read these operating instructions. Keep them in safe place accessible for all

More information

Protection components

Protection components General Application LT3-Si thermistor protection units continuously monitor the temperature of the machines to be protected (motors, generators, etc.) by means of PTC thermistor probes embedded in the

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

IMPORTANT! Please take the time to read through the manual before you start to install/program your equipment.

IMPORTANT! Please take the time to read through the manual before you start to install/program your equipment. PRODUCT DESCRIPTION IMPORTANT! Please take the time to read through the manual before you start to install/program your equipment. The systems KRC11, 12, 13 and 14 consists of two parts: the transmitter

More information

RAMSES 784 HF Set 1. Bedienungsanleitung Uhrenthermostat 1. Operating Instructions Clockthermostat 14. Mode d emploi Thermostat à horloge 26

RAMSES 784 HF Set 1. Bedienungsanleitung Uhrenthermostat 1. Operating Instructions Clockthermostat 14. Mode d emploi Thermostat à horloge 26 309 484 01 RAMSES 784 HF Set 1 784 9 407 784 9 417 Bedienungsanleitung Uhrenthermostat 1 Operating Instructions Clockthermostat 14 Mode d emploi Thermostat à horloge 26 Gebruiksaanwijzing Klokthermostaat

More information

P700WLS IoProx Receiver

P700WLS IoProx Receiver Installation Manual Warning! This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual

More information

CAMTO. Arc detecting relay. system. January Revised August D D1200

CAMTO. Arc detecting relay. system. January Revised August D D1200 NEW ARC DETECTING SYSTEM FROM Based on our experience with arc protection since 1962, has developed a new. The units are built into boxes that all fit on a 35 mm DIN-rail. All front plates are dimensioned

More information

AHC-XP. Dewpoint-guided Power Controller for Glass and Handrail Heaters. Front view. Characteristics

AHC-XP. Dewpoint-guided Power Controller for Glass and Handrail Heaters. Front view. Characteristics Dewpoint-guided Power Controller for Glass and Handrail Heaters Front view Characteristics Dew point-guided power controller for cost-optimized operation of glass and handrail heaters Digital display of

More information

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC Catalogue 1SFC 266006-en, Edition 3 November 2003 Supersedes Catalogue 1SFC 266006-en, Edition 2 November 2000 Arc Guard System TVOC System units The two units of the are used as below: Approvals 1. with

More information

Installation instructions

Installation instructions Installation instructions T70RX-03AIB, T70RX-03AWB, T70TX-02TTB, T70TX-03STB, T70TX-06TTB LANGUAGE: English (original) IM-T70-RX001-A01-EN CONTENTS Chapter 1: CUSTOMER INFORMATION 3 Chapter 2: PRODUCT

More information

Panther. Installation instructions. Receivers PN-R15-1 PN-R15-2 PN-R15-13 PN-R IM-PN-RX103-A03-EN Language: English (original)

Panther. Installation instructions. Receivers PN-R15-1 PN-R15-2 PN-R15-13 PN-R IM-PN-RX103-A03-EN Language: English (original) Panther Installation instructions Receivers IM-PN-RX0-A0-EN Language: English (original) PN-R5- PN-R5-2 PN-R5- PN-R5-4 CONTENTS Chapter : CUSTOMER INFORMATION Chapter 2: FUNCTIONAL SAFETY 6 Chapter : PRODUCT

More information

USER'S MANUAL DMR-6700

USER'S MANUAL DMR-6700 USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103129_en_01 PHOENIX CONTACT - 05/2008 1 Description QUINT POWER power supply units highest system availability

More information

This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights

This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights 1- GENERAL DESCRIPTION Electronic for the remote control of tubular motors for roller blinds, rolling shutters, doors with limit switch inside or outside the motor, radio receiver section with transmitter

More information

Radio Remote Controls Manual K Series

Radio Remote Controls Manual K Series Radio Remote Controls Manual K Series 1 PN 52764 2010.12.20 Rev. 2 K SERIES RADIO CONTROL MANUAL Conductix Incorporated The technical data and images which appear in this manual are for informational purposes

More information

QUINT-PS/ 3AC/24DC/40

QUINT-PS/ 3AC/24DC/40 Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum

More information