Basic Characteristics Data
|
|
- Godwin Norton
- 5 years ago
- Views:
Transcription
1 Basic Characteristics Data Basic Characteristics Data Model Circuit method Switching frequency [khz] Input current *1 [A] Inrush current protection PCB/Pattern Material Single sided Double sided Series/Parallel operation availability *2 Series operation Parallel operation 1F Flyback converter.26 LF CEM-3 Yes Yes No 15F Flyback converter.35 Thermistor CEM-3 Yes Yes No 3F Flyback converter Thermistor CEM-3 Yes Yes No 5F Active fi lter 6 44 Flyback converter Thermistor CEM-3 Yes Yes No 75F Active fi lter 6 44 Flyback converter Thermistor CEM-3 Yes Yes No F Active fi lter 6 Forward converter Thermistor CEM-3 Yes Yes No 15F Active fi lter 6 Forward converter Thermistor CEM-3 Yes Yes No 24F Active fi lter 6 Forward converter SCR CEM-3 Yes Yes No 3F Active fi lter 6 Forward converter SCR CEM-3 Yes Yes No *1 The value of input current is at ACIN V and rated load. *2 Refer to 2. E-22
2 1 Function E Input voltage range 1.2 Inrush current limiting 1.3 Overcurrent protection 1.4 Overvoltage protection 1.5 Output voltage adjustment range 1.6 Output ripple and ripple noise 1.7 Isolation 1. Reducing standby power E-24 E-24 E-24 E-24 E-24 E-25 E-25 E-25 2 Series Operation and Parallel Operation E Series Operation E Parallel Operation E-26 3 Assembling and Installation E Installation method 3.2 Derating 3.3 screw 3.4 Expectancy life and warranty E-26 E-26 E-3 E-3 4 Ground E-32 5 Option and Others E Outline of options 5.2 Others E-32 E-34 E-23
3 1 Function 1.1 Input voltage range Input voltage range of the power supplies is from AC5V to AC264V (please see SPECIFICATIONS for details). In cases that conform with safety standard, input voltage range is AC-AC24V (5/6Hz). If input value doesn t fall within above range, a unit may not operate in accordance with specifi cations and/or start hunting or fail. If you need to apply a square waveform input voltage, which is commonly used in UPS and inverters, please contact us. When the input voltage changes suddenly, the output voltage accuracy might exceed the specifi cation. Please contact us. 1F, 15F, 3F A power factor improvement circuit (active fi lter) is not built-in. If you use multiple units for a single system, standards for input harmonic current may not be satisfi ed. Please contact us for details. 1F, 15F, 3F, 5F, 75F, F, 15F, 24F, 3F Operation stop voltage is set at a lower value than that of a standard version (derating is needed). -Use Conditions Output ( ) 3.3V 1F 5W (3W) 15F 7.5W (5W) 3F 1W (7.5W) 5F 15W (1W) 75F 25W (15W) F 3W (2W) 15F 5W (3W) 24F W 3F W (75W) Input AC5V or DC7V Duty 1s/3s * Please avoid using continuously for more than 1 second under above conditions. Doing so may cause a failure. 1.2 Inrush current limiting An inrush current limiting circuit is built-in. If you need to use a switch on the input side, please select one that can withstand an input inrush current. 24F, 3F Thyristor technique is used in the inrush current limiting circuit. When you turn power ON/OFF repeatedly within a short period of time, please have enough intervals so that the inrush current limiting circuit becomes operative. When the switch of the input is turned on, the primary inrush current and secondary inrush current will be generated because the thyristor technique is used for the inrush current limiting circuit. 1.3 Overcurrent protection An overcurrent protection circuit is built-in and activated at 15% of the rated current or 11% of the peak current. A unit automatically recovers when a fault condition is removed. Please do not use a unit in short circuit and/or under an overcurrent condition. Intermittent Operation Mode Intermittent operation for overcurrent protection is included in a part of series. When the overcurrent protection circuit is activated and the output voltage drops to a certain extent, the output becomes intermittent so that the average current will also decrease. 1.4 Overvoltage protection An overvoltage protection circuit is built-in. If the overvoltage protection circuit is activated, shut down the input voltage, wait more than 3 minutes and turn on the AC input again to recover the output voltage. Recovery time varies depending on such factors as input voltage value at the time of the operation. In option -R2, overvoltage protection is removed by toggling ON/ OFF signal of remote control. Remarks : Please avoid applying a voltage exceeding the rated voltage to an output terminal. Doing so may cause a power supply to malfunction or fail. If you cannot avoid doing so, for example, if you need to operate a motor, etc., please install an external diode on the output terminal to protect the unit. 1.5 Output voltage adjustment range Adjustment of output voltage is possible by using potentiometer. Please refer to instruction manual 5.1. Option -Y is recommended which can adjust the output voltage. 1F Resistance for line fi lter is used for inrush current limiting. 15F, 3F, 5F, 75F, F, 15F Thermistor is used in the inrush current limiting circuit. When you turn the power ON/OFF repeatedly within a short period of time, please have enough intervals so that a power supply cools down before being turned on. E-24
4 1.6 Output ripple and ripple noise Output ripple noise may be infl uenced by measurement environment, measuring method fi g.1.1 is recommended. 1.7 Isolation Osiloscope/ Ripple noise meter Bw:2MHz For a receiving inspection, such as Hi-Pot test, gradually increase (decrease) the voltage for the start (shut down). Avoid using Hi- Pot tester with the timer because it may generate voltage a few times higher than the applied voltage, at ON/OFF of a timer. 1. Reducing standby power 1F, 15F +Vout -Vout A circuit reducing standby power is built in 1F and 15F. (standby power :.5W typ) The load factor: Io=-35%, the internal switch element is intermittent operated, and the switching loss is decreased. The specifi cation of the Ripple/Ripple Noise changes by this intermittent operation. The value of the ripple/ripple Noise when intermittent operates changes in the input voltage and the output current. Please contact us for details. F, 15F, 24F, 3F As for option -R2, reducing standby power is possible by OFF signal of the remote control. Please refer to instruction manual 5.1. C1 C2 15mm C1 : Film capacitor.1µf C2 : Aluminum electrolytic capacitor 22µF Load Differential probe Fig.1.1 Measuring method of Ripple and Ripple Noise + 2 Series Operation and Parallel Operation 2.1 Series Operation 1F, 15F, 3F, 5F, 75F Series operation is available by connecting the outputs of two or more power supplies with the same output voltage, as shown below. Output current in series connection should be lower than the lowest rated current in each unit. 12V or less D1 D3 D2 D4 Load D1-D4 : Use a schottky barrier diode with low forward voltage. 15V or more Fig.2.2 Examples of connecting in series operation (b) F, 15F, 24F, 3F You can use a power supply in series operation. The output current in series operation should be lower than the rated current of a power supply with the lowest rated surrent among power supplies that are serially connected. Please make sure that no surrent exceeding the rated current fl ows into a power supply. Load D1 D2 Load D1,D2 : Use a schottky barrier diode with low forward voltage. Fig.2.1 Examples of connecting in series operation (a) Load Load Load Load Fig.2.3 Examples of connecting in series operation E-25
5 2.2 Parallel Operation Parallel operation is not possible. Redundancy operation is available by wiring as shown below. Power Supply Power Supply + - Even a slight difference in output voltage can affect the balance between the values of I1 and I2. Please make sure that the value of I3 does not exceed the rated current of a power supply. I3 [ the rated current value 3 Assembling and Installation 3.1 Installation method + - I1 I2 This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,so handle the unit with care. In case of metal chassis, keep the distance between d1 & d2 for to insulate between lead of component and metal chassis, use the spacer of mm or more between d1. If it is less than d1 & d2, insert the insulation sheet between power supply and metal chassis. I3 Load Fig.2.4 Example of redundancy operation There is a possibility that it is not possible to cool enough when the power supply is used by the sealing up space as showing in Figure 3.2. Please use it after confi rming the temperature of point A and point B of 3.2. Case Power supply Fig.3.2 Installation example 3.2 Derating Environment to use it and Installation environment When using it,it is necessary to radiate heat by the heat of the power supply. Table shows the relation between the upper limit temperature (Point A and Point B) and load factors. Please consider the ventilation so that the convection which is enough for the whole power supply is provided. And temperature of Point A and Point B please become lower than upper limit temperature. The expectancy life in the upper bound temperature (Point A and Point B) is three years or more. Please refer to External View for the position of Point A and Point B. In case of with Chassis and Cover, please contact our sales offi ce for getting more information. Remarks: *Please be careful of electric shock or earth leakage in case of temperature measurement, because Point A and Point B is live potential. *Please refer to 3.4 if you want to extend the longevity of the expectancy life. d2 d2 d1= mm min d2 d2 d2 =4mm min d2 Fig.3.1 Installation method Table 3.1 Temperatures of Point A, Point B 1F-O A 2% <Io[% 7 4 Io[2% B 2% <Io[% 7 1 Io[2% C 2% <Io[% 76 Io[2% D 2% <Io[% 7 7 Io[2% E 2% <Io[% 73 4 Io[2% F 2% <Io[% 74 Io[2% %<Io[% Io[7% E-26
6 Table 3.2 Temperatures of Point A, Point B 15F-O A 4% <Io[% 72 Io[4% 77 1 B 4% <Io[% 6 73 Io[4% 74 7 C 4% <Io[% 75 4 Io[4% 7 1 D 4% <Io[% Io[4% E 4% <Io[% 7 79 Io[4% 76 1 F 4% <Io[% 71 7 Io[4% 76 7%<Io[% Io[7% Table 3.3 Temperatures of Point A, Point B 3F-O A 7% <Io[% Io[7% B 6% <Io[% Io[6% 2 C 7% <Io[% 77 Io[7% 3 7%<Io[% 72 7 D 2%<Io[7% 77 Io[2% 79 7%<Io[% E 2%<Io[7% 79 5 Io[2% 77 1 F 7% <Io[% Io[7% %<Io[% Io[7% Table 3.4 Temperatures of Point A, Point B 5F-O A 7% <Io[% 6 6 Io[7% 6 77 B 7% <Io[% Io[7% 77 7 C 5% <Io[% 7 71 Io[5% 4 77 D 5% <Io[% 3 6 Io[5% 5 72 E 5% <Io[% Io[5% 3 1 F 5% <Io[% 7 Io[5% %<Io[% Io[7% Table 3.5 Temperatures of Point A, Point B 75F-O A 7% <Io[% 5 7 Io[7% 6 76 B 7% <Io[% Io[7% 1 71 C 7% <Io[% 1 6 Io[7% %<Io[% 7 5 D 1%<Io[7% 63 Io[1% %<Io[% E 1%<Io[7% 3 6 Io[1% 3 79 F 7% <Io[% Io[7% %<Io[% Io[7% Table 3.6 Temperatures of Point A, Point B F-O A B 7%<Io[% %<Io[7% 79 Io[5% 3 7%<Io[% %<Io[7% 7 2 Io[5% 6 C 7% <Io[% 7 2 Io[7% 5 D 7% <Io[% 7 Io[7% 5 E 7% <Io[% 74 5 Io[7% 7%<Io[% F 5%<Io[7% 77 Io[5% 79 7%<Io[% Io[7% Table 3.7 Temperatures of Point A, Point B 15F-O A B C D, F E 6%<Io[% %<Io[6% 6 5 Io[2% 7 7 7%<Io[% %<Io[7% 5 7 Io[3% 6 1 6%<Io[% %<Io[6% 6 1 Io[3% 7 3 7%<Io[% %<Io[7% 3 76 Io[3% %<Io[% %<Io[7% 2 3 Io[3% 3 4 7%<Io[% Io[7% E-27
7 Table 3. Temperatures of Point A, Point B 24F-O A B C D E F 75%<Io[% %<Io[75% 2 79 Io[5% %<Io[% %<Io[75% Io[5% %<Io[% %<Io[75% 1 79 Io[5% %<Io[% %<Io[75% Io[5% %<Io[% %<Io[75% Io[5% %<Io[% %<Io[75% Io[5% 4 3 7%<Io[% Io[7% Table 3.9 Temperatures of Point A, Point B 3F-O A B C D E F 7%<Io[% %<Io[7% Io[4% %<Io[% %<Io[7% 6 6 Io[4% %<Io[% %<Io[7% 73 7 Io[4% %<Io[% %<Io[7% 6 63 Io[4% %<Io[% %<Io[7% 65 4 Io[4% %<Io[% 4%<Io[7% Io[4% 7%<Io[% Io[7% The operative ambient temperature is different by with / without chassis cover or position. Derating curve is shown below. Note: In the hatched area, the specifi cation of Ripple, Ripple Noise is different from other area. 1F [4] 6 [5] 7 [6] Fig.3.3 Ambient temperature derating curve (refer to Table 3.1) 15F Fig.3.4 Ambient temperature derating curve (refer to Table 3.2) 3F * Inside[ ] is with case cover Fig.3.5 Ambient temperature derating curve (refer to Table 3.3) 5F 1 (A), (D), (E), (F) 1 2Forced air (.5m 3 /min) * Inside[ ] is with case cover 1 (E), (F) 1 2Forced air (.5m 3 /min) * Inside[ ] is with case cover * Inside[ ] is with case cover 1(B), (C) 1(A), (B), (C), (D) [3] 5 [4] 6 [5] 7 [6] (D), (E) 1 (F) 1 2Forced air (.5m 3 /min) 1(A), (C) 1(B) [3] 5 [4] 6 [5] 7 [6] (D) 1 (C), (E) 1 (F) 1 2Forced air (.5m 3 /min) 1(B) 1(A) [1] 4 [2] 5 [3] 6 [4] 7 [5] Fig.3.6 Ambient temperature derating curve (refer to Table 3.4) E-2
8 75F [1] 4 [2] 5 [3] 6 [4] 7 [5] * Inside[ ] is with case cover Fig.3.7 Ambient temperature derating curve (refer to Table 3.5) F F 24F 1 (D) 1 (E), (F) 1 2Forced air (.5m 3 /min) 1 (D), (E), (F) 1 2Forced air (.5m 3 /min) 1(C) 1(A), (B) 1 (C) 1 (A) (B) Fig.3. Ambient temperature derating curve (refer to Table 3.6) Forced air (.5m 3 /min) Fig.3.9 Ambient temperature derating curve (refer to Table 3.7) (C) 1 (D), (E), (F) 1 (B) 1 (A) 1 (D), (F) 1 (C) 1 (B) 1 (E) 1 2Forced air (.5m 3 /min) (A) Fig.3.1 Ambient temperature derating curve (refer to Table 3.) F-O-SN 24F-O-SN 3F Fig.3.9 Ambient temperature derating curve (refer to Table 3.6) Fig.3.13 Ambient temperature derating curve (refer to Table 3.) (D), (E) 1 (C) 1 2Forced air (.5m 3 /min) 1 (D) 1 (E) 1 2Forced air (.5m 3 /min) 1 (D), (E) 1 (F) 1 2Forced air (.5m 3 /min) 1 (C) Forced air (.5m 3 /min) (B), (C) 1 (B) 1 (A) 1 (B) 1 (A) 1 (A) Fig.3.14 Ambient temperature derating curve (refer to Table 3.9) Fig.3.15 Ambient temperature derating curve (refer to Table 3.9) Forced air (.5m 3 /min) Fig.3.16 Ambient temperature derating curve (refer to Table 3.9) E-29
9 Derating curve depending on input voltage Derating curve depending on input voltage is shown in Fig.3.. [%] [AC V] 5 9 Fig.3.17 Derating curve depending on input voltage method (A) (B) (C) 1F, 15F Fig.3.19 Allowance of metal parts for (1F, 15F) 3F, 5F, 75F, F, 15F Unit [mm] Standard Position (D) (E) (F) (F) is not possible when unit is with case cover, but if need to operate unit by (F) positioning with case cover, temperature / load derating is necessary. For more details, please contact our sales or engineering departments. 3.3 screw Fig.3.1 method The screw should be M3. The hatched area shows the allowance of metal parts for. If metallic fi ttings are used on the component side of the board, ensure there is no contact with surface mounted components. This product uses SMD technology. Please avoid the PCB installation method which includes the twisting stress or the bending stress. *Recommendation to electrically connect FG to metal chassis for reducing noise. Unit [mm] Fig.3.2 Allowance of metal parts for (3F, 5F, 75F, F, 15F) 24F, 3F 3.4 Expectancy life and warranty Expectancy Life. Table 3.1 Expectancy Life (1F-O) temperature (year) A, D, E, F B, C Expectancy Life Io[75% 75%<Io[% Ta = 4C or less 6years 6years Ta = 5C 5years 3years Ta = 45C or less 6years 6years Ta = 55C 5years 3years Table 3.11 Expectancy Life (15F-O) temperature (year) A, B, C, D E, F, TB1 Fig.3.21 Allowance of metal parts for (24F, 3F) Unit [mm] Expectancy Life Io[75% 75%<Io[% Ta = 4C or less 6years 6years Ta = 5C 5years 3years Ta = 35C or less 6years 6years E-3
10 Table 3.12 Expectancy Life (3F-O) A, B, C D, E, F Expectancy Life Ta = 4C or less 6years 6years Ta = 5C 5years 3years Ta = 35C or less 6years 6years Table 3.13 Expectancy Life (5F-O) A B, D C, E F Expectancy Life Ta = 4C or less 6years 6years Ta = 5C 5years 3years Ta = 35C or less 6years 6years Ta = 3C or less 6years 6years Ta = 4C 5years 3years Ta = 25C or less 6years 6years Ta = 35C 5years 3years Table 3.14 Expectancy Life (75F-O) A, B C D E, F Expectancy Life Ta = 4C or less 6years 6years Ta = 5C 5years 3years Ta = 35C or less 6years 6years Ta = 3C or less 6years 6years Ta = 4C 5years 3years Ta = 2C or less 6years 6years Ta = 3C 5years 3years Table 3.15 Expectancy Life (F-O) A B, C D, E, F Expectancy Life Ta = 4C or less 6years 6years Ta = 5C 5years 3years Ta = 35C or less 6years 6years Ta = 35C or less 6years 6years Table 3.16 Expectancy Life (15F-O) A B C Expectancy Life Ta = 3C or less 6years 6years Ta = 4C 6years 5years Ta = 25C or less 6years 6years Ta = 35C 6years 6years Ta = 25C or less 6years 6years Ta = 35C 6years 5years D, F Ta = 25C or less 6years 6years E Ta = 25C or less 6years 5years Ta = 6C 5years 5years Table 3.17 Expectancy Life (24F-O) A B, C Expectancy Life Ta = 3C or less 6years 6years Ta = 4C 5years 3years Ta = 2C or less 6years 6years Ta = 3C 5years 3years D, F Ta = 2C or less 6years 5years E Ta = 15C or less 6years 5years Table 3.1 Expectancy Life (3F-O) A B, C D, E F Expectancy Life Ta = 3C or less 6years 6years Ta = 4C 5years 3years Ta = 2C or less 6years 6years Ta = 3C 5years 3years Ta = 15C or less 6years 6years Ta = 25C 5years 3years Ta = 1C or less 6years 6years Ta = 2C 5years 3years Ta = 5C 5years 3years Table 3.19 (1F-O) A, D, E, F B, C Ta = 4C or less 5years 5years Ta = 5C 5years 3years Ta = 45C or less 5years 5years Ta = 55C 5years 3years Table 3.2 (15F-O) A, B, C, D E, F Ta = 4C or less 5years 5years Ta = 5C 5years 3years Ta = 35C or less 5years 5years Table 3.21 (3F-O) A, B, C D, E, F Ta = 4C or less 5years 5years Ta = 5C 5years 3years Ta = 35C or less 5years 5years E-31
11 Table 3.22 (5F-O) A B, D C, E F Ta = 4C or less 5years 5years Ta = 5C 5years 3years Ta = 35C or less 5years 5years Ta = 3C or less 5years 5years Ta = 4C 5years 3years Ta = 25C or less 5years 5years Ta = 35C 5years 3years Table 3.23 (75F-O) A, B C D E, F Ta = 4C or less 5years 5years Ta = 5C 5years 3years Ta = 35C or less 5years 5years Ta = 3C or less 5years 5years Ta = 4C 5years 3years Ta = 2C or less 5years 5years Ta = 3C 5years 3years Table 3.24 (F-O) A B, C D, E, F Ta = 4C or less 5years 5years Ta = 5C 5years 3years Ta = 35C or less 5years 5years Ta = 25C or less 5years 5years Ta = 35C 5years 3years Table 3.25 (15F-O) A B C Ta = 3C or less 5years 5years Ta = 4C 5years 5years Ta = 25C or less 5years 5years Ta = 35C 5years 5years Ta = 25C or less 5years 5years Ta = 35C 5years 3years D, F Ta = 25C or less 5years 5years E Ta = 25C or less 5years 3years Table 3.26 (24F-O) A B, C 4 Ground When installing the power supply with your unit, ensure that the input FG terminal of or hole FG is connected to safety ground of the unit. 5.1 Outline of options *Please inquire us for details of specifi cations and delivery timing. *You can combine multiple options. Some options, however, cannot be combined with other options. Please contact us for details. -C Ta = 3C or less 5years 5years Ta = 4C 5years 3years Ta = 2C or less 5years 5years Ta = 3C 5years 3years D, F Ta = 2C or less 5years 3years E Ta = 15C or less 5years 3years Table 3.27 (3F-O) A B, C D, E F Ta = 3C or less 5years 5years Ta = 4C 5years 3years Ta = 2C or less 5years 5years Ta = 3C 5years 3years Ta = 15C or less 5years 5years Ta = 25C 5years 3years Ta = 1C or less 5years 5years Ta = 2C 5years 3years Ta = 5C 5years 3years 5 Option and Others -Option -C units have coated internal PCB for better moisture resistance. E-32
12 -G -Option -G units are low leakage current type. -Differences from standard versions are summarized in Table 5.1. Table 5.1 Low leakage current type Leakage Current.15mA max (AC24V 6Hz) Conducted Noise N/A Please contact us for details about Output Ripple Noise Ripple Noise * This is the value that measured on measuring board with capacitor of 22µF at 15mm from output connector. Measured by 2MHz oscilloscope or Ripple-Noize meter (Equivalent to KEISOKU-GIKEN:RM-13). -H (F-24, 15F-24, 24F-24, 3F-24-TY) -Option -H units can output the peak current. -Peak load is possible to draw as below. Output current [A] t 1 t 2 l p : peak current lave : average current -S--SN --S indicates a type with chassis, and -SN indicates a type with chassis and cover (Refer to external view). Refer to Derating Curves in Section SNF (3F) -In option -SNF, the cover, chassis and cooling fan are added. -The appearance of option -J units is defferent from the of standard appearance. Please contact us about the detail. -Y -Option -Y units can adjust the output voltage by the potentiometer is attached. -Refer to the adjustable range to the table 5.2 and table F, 15F, 3F, 5F, 75F Table 5.2 Output voltage adjustment range Output voltage adjustment range[v] 3.3V* 2.5 to V 4.5 to V 1. to V 13.5 to V 21.6 to V 32.4 to V 43.2 to 52. *Some of the product, -Y is standard equipment. (1F-3R3-Y,15F-3R3-Y,3F-3R3-Y, 5F-3R3-Y,75F-3R3-Y) Input voltage is AC9V to AC264V. t1[1[sec] lp[rated peak current lave[rated output current Duty = t1 X[%] [35% t1+t2 In case of 3F duty is depended on peak wattage. Please contact us about the detail. Remarks: *There is possibility that an internal device is damaged when the specifi cation is exceeded. -J (3F) -Option -J units, the input and output connector are changed to EP connectors (Mfr. Tyco Electronics). -The appearance in option -J units is defferent from the standard untis. Please contact us about the detail. -J1 Fig.5.1 Peak current -Option -J1 units, the Input and Output connector is VH connectors (Mfr. J.S.T.). -3F appearance of option -J units is defferent from the standard appearance. Please contact us for ditail about the detail. F, 15F, 24F, 3F Table 5.3 Output voltage adjustment range Output voltage adjustment range[v] 3.3V* 2.5 to V* 4.5 to V 1. to V 13.5 to V 21.6 to V 32.4 to V 39.6 to 52. *Some of the product, -Y is standard equipment. (F-3R3-Y, F-5-Y, 15F-3R3-Y, 15F-5-Y, 3F-O-TY) -To increase an output voltage, turn a built-in potentiometer clockwise. -To decrease the output voltage, turn it counterclockwise. -Please take care when you adjust output voltage by potentiometer, because there is possibility of electric shock and the breakdown as contacting to other internal circui by telectrically conductive tool. E-33
13 -R (F, 15F, 24F, 3F) -You can control output ON/OFF remotely in Option -R units. To do so, connect an external DC power supply and apply a voltage to a remote ON/OFF connector, which is available as option. Model Name F, 15F, 24F, 3F Built-in Resistor Ri [ W ] Voltage between RC (+) and RC (-) [V] Output ON Output OFF Input Current [ma] max -T (24F, 3) -Option -T units have vertically positioned screws on a terminal block. -Please contact us for details about appearance. FG AC (N) AC (L) -V +V External Power Source R *1 Input Current SW RC (+) RC (-) 1 2 Inside of a Power Supply Ri Fig.5.3 Example of option -T The screw can be held to terminal block by inserting and lifting the screwdriver from the side of terminal block. + screwdriver screw Remote ON/OFF connector (Optional) Fig.5.2 Example of using a remote ON/OFF circuit - Dedicated harnesses are available for your purchase. Please see Optional Parts for details. *1 If the output of an external power supply is within the range of V, you do not need a current limiting resistor R. If the output exceeds 12.5V, however, please connect the current limiting resistor R. To calculate a current limiting resistance value, please use the following equation. Vcc-(1.1+RiX.5) R[W]=.5 * Please wire carefully. If you wire wrongly, the internal components of a unit may be damaged. Remote ON/OFF circuits (RC+ and RC-) are isolated from input, output and FG. -R2 (F, 15F, 24F, 3F) -The usege is the same as option -R, please refer to Option -R. -Reducing standby power is possible by OFF signal of the remote control. -Start up time by ON signal in remote control is 35ms(typ). -The latch condition in overvoltage protection is removed by toggling ON/OFF signal of remote control. -Standby power F,15F,24F.2Wtyp (ACV),.7Wtyp (AC2V) 3F.25Wtyp (ACV), 1.1Wtyp (AC2V) f5.5max -T1 (3F) -Option -T units have horizontally positioned screws on a terminal block. -Please contact us for details about appearance. FG AC (N) AC (L) 5.2 Others Fig.5.4 lifting method Fig.5.5 Example of option -T1 terminal block This power supply is the rugged PCB type. Do not drop conductive objects in the power supply. At light load, there remains high voltage inside the power supply for a few minutes after power OFF. So, at maintenance, take care about electric shock. This power supply is manufactured by SMD technology. The stress to PCB like twisting or bending causes the defect of the unit, so handle the unit with care. -Tighten all the screws in the screw hole. -Install it so that PCB may become parallel to the clamp face. -Avoid the impact such as drops. -V +V E-34
14 While turning on the electricity, and for a while after turning off, please don t touch the inside of a power supply because there are some hot parts in that. When a mass capacitor is connected with the output terminal (load side), the output might become the stop or an unstable operation. Please contact us for details when you connect the capacitor. 1F, 15F When these power supplies are connected to the input terminal in parallel, the total capacitance between line and line becomes big. Therefore, the electrical discharge resistance on the safety standard might become necessary. Please contact us for details when safety standard is necessary at multiple units usage. E-35
NEMIC-LAMBDA SWS Series INSTRUCTION MANUAL
NEMICLMBD SWS 5 75 1 15 Series 1. Explanation SWS5, SWS75 2. connecting method Input must be off when making connection. Connect FG terminal to ground terminal of the equipment. current of each terminal
More informationMODEL GHA300F-12 GHA300F-24 GHA300F-48 VOLTAGE[V] AC f (output derating is required at AC90V -115V *3) CURRENT[A]
AC-DC Power Supplies Medical Type GHA300F Ordering information GH A 300 F -OO -O 3 4 5 6 R Example recommended EMI/EMC filter EAC-0-47 High voltage pulse noise type : EAP series Low leakage current type
More informationMODEL GHA300F-12 GHA300F-24 GHA300F-48 VOLTAGE[V] AC f (output derating is required at AC90V -115V *3) CURRENT[A]
AC-DC Power Supplies Medical Type GHA300F Ordering information GH A 300 F -OO -O 3 4 5 6 R Example recommended EMI/EMC filter EAC-0-47 High voltage pulse noise type : EAP series Low leakage current type
More informationMODEL LEP100F-24 LEP100F-36 LEP100F-48 VOLTAGE[V] AC f or DC
AC-DC Power Supplies Open Frame/ Enclosed Type 00F Ordering information 00 F -2 -O 2 3 R Recommended EMI/EMC Filter NAC-06-72 High voltage pulse noise type : NAP series Low leakage current type : NAM series
More informationOperation Manual. SWF Series Switch Mode Power Supply. SANKEN ELECTRIC CO., LTD No.PAN E-01.
Operation Manual SWF Series Switch Mode Power Supply 1 Table of Contents Safety Precautions 3 Appearance and Meaning of Safety Warnings 4 Hazard and Caution Safety Warnings 4 Introduction to SWF Series
More informationMODEL ADA600F-24 ADA600F-30 ADA600F-36 ADA600F-48 VOLTAGE[V] AC f or DC (AC64 or DC90 optionally available *6) FREQUENCY[Hz]
AC-DC Power Supplies Enclosed type 600F Ordering information 600 F -24 -O 1 2 3 4 5 R Please refer to derating curve, because the rated load depends on cooling method that is convection cooling or forced
More informationMODEL ADA600F-24 ADA600F-30 ADA600F-36 ADA600F-48 VOLTAGE[V] AC f or DC (AC64 or DC90 optionally available *6) FREQUENCY[Hz]
ADA R AC-DC Power Supplies Enclosed Type ADA600F Ordering information ADA 600 F -24 -O 1 2 3 4 5 Please refer to derating curve, because the rated load depends on cooling method that is convection cooling
More information1. Output Power vs. Ambient temperature a. 3.3 and 5 V models b. All other models. Load factor Convection
VPU-S Series Switching Power Supply / Rev. 3-6 Features Universal input 8~64 Vac or ~34 Vdc Power factor correction Output over-current protected Output over-voltage protected Remote sense Remote on/off
More informationCURRENT1[A] CURRENT2[A]*
PBA/PBW AC-DC Power Supplies Enclosed Type PBW15F Ordering information PB W 15 F -O -O 1 2 3 4 5 6 R Recommended EMI/EMC Filter NAC-06-472 High voltage pulse noise type : NAP series Low leakage current
More informationPrecautions in Using the product:
DP Series ISTRUCTIO MAUA 6. Avoid penetration of metal chips when processing mounting holes. 7. Avoid places where the products is subjected to penetration of liquid, foreign substance, or corrosive gas.
More informationQualification of CHS series (Bus Converter applications) to Intermediate Bus Architecture
Qualification of CHS series (Bus Converter applications) to Intermediate Bus Architecture VER3. Applications Manual CHS series Page 1. Ordering information 2. Pin configuration/ External view 1-1 2-1 2.1
More informationBasic Characteristics Data
Basic Characteristics Data Basic Characteristics Data Model Circuit method Material PCB/Pattern Single sided Double sided KRE-2A Diode FR-4 Yes KRE-4A Diode FR-4 Yes KR-4 1 Terminal Blocks 2 Functions
More informationAC/DC Power Supply Series APPLICATION NOTE
ZMS100 AC/DC Power Supply Series APPLICATION NOTE ZMS100 Application Notes Issue 3 Document Number 260160 Page 1 of 15 Contents Contents... 2 1. INPUT... 3 AC INPUT LINE REQUIREMENTS... 3 2. DC OUTPUT...
More informationAD240 AD O AD-2 SPECIFICATIONS. AC-DC Power Supplies Enclosed type
AC-DC Power Supplies Enclosed type Ordering information - -O 1 2 3 4 1Series name 2Output wattage 3Output voltage 4Optional C :with Coating G :Low leakage current P :Parallel operation R :with Remote ON/OFF
More informationVOF XX - XXX - X
date 01/31/018 page 1 of 10 SERIES: VOF-300 DESCRIPTION: AC-DC POWER SUPPLY FEATURES up to 300W continuous power universal input voltage range industry standard 3 x 5 footprint power factor correction
More informationVMS-300A - XX - XXX - X
date 05/16/017 page 1 of 10 SERIES: VMS-A DESCRIPTION: AC-DC POWER SUPPLY FEATURES up to W continuous power universal input voltage range industry standard 3 x 5 footprint power factor correction remote
More informationDLP/E Series Instruction Manual
Instruction Manual BEFORE USIG TE POWER SUPPY UIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
More informationAC/DC Power Supply Series APPLICATION NOTE
-175 AC/DC Power Supply Series APPLICATION NOTE 69493 NV175 App note 6a.doc Document Number 69493 Page 1 of 20 1. INPUT... 4 AC INPUT LINE REQUIREMENTS... 4 2. DC OUTPUT... 4 OUTPUT VOLTAGES all models
More informationAC/DC Power Supply Series APPLICATION NOTE
-175 AC/DC Power Supply Series APPLICATION NOTE 69493 NV175 App note 4.doc Document Number 69493 Page 1 of 17 1. INPUT...3 AC INPUT LINE REQUIREMENTS... 3 2. DC OUTPUT...3 OUTPUT VOLTAGES... 3 REMOTE SENSE...
More informationSPECIFICATION FOR APPROVAL
Scanning LIB. SPECIFICATION FOR APPROVAL CUSTOMER : ITEM : Power Supply Unit. DESCRIPTION : LCD & LED Monitor Power Supply. CUSTOMER P/NO : SUPPLIER P/NO : BRK-3500 DATE : 2015-10-05 CUSTOMER EN GR CHKD
More informationTable 2 Models BST12L-0.7S10PDM BST12L-0.7S16PDM BST12L-0.7S25PDM Conditions Input voltage range
Information The BST2L series is a small, thin, highly efficient and low noise non-isolated type step down DC-DC converter with 2 input that has been developed for distributed feeding. Output voltage is
More informationDSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.
15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty
More informationJ SERIES JBW. Wide input, compact and device-embedded type
(/) Wide input, compact and device-embedded type J SERIES JBW UL/CSA, EN9 approved and Electric Appliances And Material Control Law compliant, CE marking product (-year warranty period) [FEATURES] Compact
More informationSE014S110 Power Module; dc-dc Converter: 48 Vdc Input, 110 Vdc Output, 14 W
Data Sheet SE014S110 Power Module; dc-dc Converter: Features The SE014S110 Power Module uses advanced, surface-mount technology and delivers high-quality, compact, dc-dc conversion at an economical price.
More informationCCG Series Instruction Manual
Series Instruction Manual TDK Lambda BEFORE USING THE POWER SUPPLY Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using
More informationAll specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.
KEY FEATURES Open Frame Switching Power Supply Remote ON/OFF Function 240 Watt with Free Air Convection 500 Watt with 30CFM FAN Built-in 12V/0.3A Auxiliary Output Standby 5V@1A with Fan, @0.4A without
More informationADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W
ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000
More informationABC400 Series is a compact and efficient series of AC-DC open frame power supplies suited for telecom, datacom and many other applications.
is a compact and efficient series of AC-DC open frame power supplies suited for telecom, datacom and many other applications. The family meets the international information technology safety standards
More informationAC/DC Power Supply Series APPLICATION NOTE
-175 AC/DC Power Supply Series APPLICATION NOTE NV175 Application notes 3.4.doc Document Number 69493 Page 1 of 16 1. INPUT...3 AC INPUT LINE REQUIREMENTS... 3 2. DC OUTPUT...3 OUTPUT VOLTAGES... 3 REMOTE
More informationAll specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.
DPO-500 KEY FEATURES Open Frame Switching Power Supply Remote ON/OFF Function 240 Watt with Free Air Convection 500 Watt with 30CFM FAN Built-in 12V/0.3A Auxiliary Output Standby 5V@1A with Fan, @0.6A
More informationWatts HCP Series
ACDC 6 Watts HCP Series High Efficiency up to 9% xppower.com High Power Density Programmable Output Voltage (%%) Programmable (%%) Parallel Operation Fully Featured Signals & Controls Year Warranty Specification
More informationPDAM500 Series 500W Power Supply
UL / IEC / EN 60601 3.1 Edition & UL / IEC / EN 60950 AM2 Safety Approvals High power density: 500W in 3 x 5 footprint Open Frame or Enclosed Versions Available Remote ON/OFF Function Built-in 12V/0.3A
More informationAmerican Power Design, Inc.
FEATURES 4 Customer Selects Output Voltage 4 Outputs to 28 Vdc 4 Wide Input Ranges (10-20Vdc, 18-36Vdc, 20-60Vdc, 36-72Vdc) 4 Excellent Line & Load Regulation 4 500 Vdc Output Isolation 4 Continuous Short
More informationVP ELECTRONIQUE MASSY - Tel:
KEY FEATURES Switching Power Module for PCB Mountable Fully Encapsulated Plastic Case Universal Input Range 90-264VAC, 47-440 Hz Regulated Low Ripple and Noise Small Size But Higher Wattage Screw Terminal
More informationFS10 Series AC-DC Converter Compact Case(Power tank)
Electrical specifications INPUT Voltage Current Frequency Efficiency Inrush current (at cold start) Leakage current AC85~264V (or DC 110~340V) 50/60Hz (note) 0.25A Max. @ 110VAC / 0.13A Max. @ 220VAC 47~440Hz
More informationC30 Series AC-DC Converter
Features UL, CE Approved RoHS directive compliance Small, compact size High efficiency Universal input(ac90~264v or DC120~340V) Surface mounting technology Built in EMI filter Inrush current limit 100kHz
More informationSample Test Data SWF Series SWF100P W, High Surge Tolerant, Low Noise Power Supply
Sample Test Data SWF Series SWF100P-24 100 W, High Surge Tolerant, Low Noise Power Supply General Description The SWF series are compact, wide ranging power supplies, providing peak power capability that
More informationWIDE SELECTION OF LINE UP RANGE FROM GENERAL INDUSTRIAL, MEDICAL, HEAVY DUTY TO POWER SUPPLY WITH PEAK OUTPUT HWS
HWSSeries WIDE SELECTION OF LINE UP RANGE FROM GENERAL INDUSTRIAL, MEDICAL, HEAVY DUTY TO POWER SUPPLY WITH PEAK OUTPUT HWS Series put together the concept of "Environment-friendly", "User-friendly", and
More informationPower supply CP-T 24/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings
ECP225- Series C-DC Power Supplies 225 Watts Low Profile High Power Density 3 by 5.0 Footprint 50 W Convection/ 225 W Force Cooled Ratings 5 V Standby and 2 V Fan Outputs Medical and ITE pprovals High
More information150 Watt Industrial (WLT)
150 Watt Industrial (WLT) Features 4 x 2 x 1.3 inches form factor 150 W with forced-air cooling Class 1 & Class 2 options 12 V @ 0.5 A fan voltage auxiliary output High efficiency > 86% Low conducted and
More informationAmerican Power Design, Inc.
FEATURES 4 Customer Selects Output Voltage 4 Outputs to 28 Vdc 4 Wide Input Ranges (10-20Vdc, 18-36Vdc, 20-60Vdc, 36-72Vdc) 4 Excellent Line & Load Regulation 4 Low Output Ripple 4 500 Vdc Output Isolation
More informationAC/DC Power Supply Single-Output
AC/DC Power Supply Single-Output The PFD-series is switcher designed to meet harmonic current distortion. The series has nominal 120 watts with a peak load of 240 watts during 10 seconds. The PFD is especially
More informationAC/DC Power Supply Series APPLICATION NOTE
-350 + -700 AC/DC Power Supply Series APPLICATION NOTE NV350_NV700 App notes 69498 12.doc Document Number 69498 Page 1 of 17 1. INPUT... 3 AC INPUT LINE REQUIREMENTS... 3 2. DC OUTPUT... 3 OUTPUT VOLTAGES...
More informationPower supply CP-T 48/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationPower supply CP-E 24/20.0
2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output
More informationPSU s e r i es
000W Single Output Power Supply PSU48-000-0 s e r i es SPECIFICATION MODEL OUTPUT INPUT PROTECTION FUNCTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER
More informationFor more information, please visit the product page. output. output current max (A)
date 12/12/217 page 1 of 1 SERIES: VMS-2 DESCRIPTION: AC-DC POWER SUPPLY FEATURES compact 2 x 4 high power-density design (CNF version is 2.4 x 4.6 ) universal input range efficiencies up to 93.5% 4th
More informationPower supply CP-T 48/5.0 Primary switch mode power supply
Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationPower supply CP-T 24/10.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/10.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More information800W Single Output Power Supply
Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( 0% ~ 05% ) U profile, High power density Constant current limiting High efficiency up
More information200 WATT TH SERIES DC/DC CONVERTERS
Features 4:1 Input voltage range High power density Small size 2.4 x 2.28 x 0.65 Efficiency up to 90 Excellent thermal performance with metal case Pulse-by-pulse current limiting Over-temperature protection
More informationLZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H
LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual IM-LZSA500-3 January 2008 Revision H Table of Contents LZS-A500-3 Power Supply 1) Safety and Recommended Practices 2 1.1 General
More informationDeclaration of Conformity to the DeviceNet Specification
Declaration of Conformity to the DeviceNet Specification ODVA hereby issues this Declaration of Conformity to the DeviceNet Specification for the product(s) described below. The Vendor listed below (the
More informationDC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output
THN 20WI Series Application Note DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output Pending Applications Wireless
More informationThese medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.
The ABC450 Series of open-frame power supplies, with its wide universal 90-264 VAC input range and high power density, is available at 450 W of output power and a variety of single and multiple output
More informationCLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby
; 12Vout @ 0.25A stdby Applications Industrial equipment LED Signage Telecommunications equipment Description Features Compact size 50.8mm x 101.6mm x 36.1mm (2in x 4in x 1.4in) with density of 18W/in
More information420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant
SHP350 Series 420 W High Line Output Power Rugged Industrial Construction Variable Speed Fan for Noise Reduction -40 C to +70 C Operation AC OK, Remote On/Off and Active Current Share Screw Terminals SEMI
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationR S P series
.. R S P - 0 0 0 series SPECIFICATION MODEL OUTPUT INPUT DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max.) Note. VOLTAGE ADJ. RANGE 0 ~ 3.5V VOLTAGE TOLERANCE Note.3 LINE REGULATION
More informationCS Series. Compact, Cost-effective, High Reliability Switching Power Supply. TDK-Lambda Introduces CS series
TDK-Lambda Introduces CS series Compact, Cost-effective, High Reliability Switching Power Supply CS Series High Reliability, Industrial AC-DC Power Supply For the requirements of high reliability of industrial
More informationPower supply CP-D 24/4.2 Primary switch mode power supply
Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution
More informationsolo Ultra-high efficiency 1U size Xsolo Single Output Power Supply 500W W 2 FEATURES APPLICATIONS INCLUDE
XS XS solo Ultra-high efficiency 1U size FEATURES The family of single output power supplies provides up to an incredible 1008W in an extremely compact package. Single output: 24V, 36V or 48V IEC60950
More informationCLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power
Applications Industrial equipment Telecommunications equipment Features Compact size 50.8 mm x 101.6 mm x 37.25 mm (2 in x 4 in x 1.47 in) with density of 18 W/in 3 Universal AC Input Range (90 264VAC)
More information1500W Single Output Power Supply AK V 100A 0~100A 1500W. 150mVp-p. Adjustment of output current is between 40 ~ 105% of rated output
AK-0 Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to % +5V / 0.5A auxiliary output Intelligent LED indicators.5u
More informationCLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power
Applications Telecommunications equipment Embedded Computing Storage Systems Industrial equipment Features Compact size 50.8 mm x 101.6 mm x 36.1 mm (2 in x 4 in x 1.4 in) with density of 13.4W/in 3 Universal
More information24V 40A 0 ~ 40A 960W. 150mVp-p 20 ~ 26.4V 83% 85% 88% 88% 90%
000W Single Output Power Supply RSP-000 s eries SPECIFICATION MODEL OUTPUT INPUT PROTECTION FUNCTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE
More informationXSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES
XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES Advanced Energy's Xsolo series, part of our low voltage solutions, delivers an incredible convection-cooled 504 W in an
More information1500W Programmable Single Output AK V. 48V Rated Current. 31.3A Current Range 100A. 0~31.3A Rated Power 0~100A 1500W
500W Programmable Single Output AK-500 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (40% ~ 05%) +5V / 0.5A auxiliary output High power
More informationRSP-2000 Series 2000W Single Output Enclosed Power Supplies
RSP-000 Series 000W Single Output Enclosed Power Supplies Features Universal AC input / Full range Built-in active PFC function High efficiency up to 9% Forced air Cooling by built-in DC fan Output voltage
More informationPower supply CP-D 12/2.1
2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power
More informationPower supply CP-D 24/1.3
2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power
More information60W 75W 80W 81.6W 81W 82.8W 81.9W 81.6W 81W
SPECIFICATION MODEL OUTPUT INPUT PROTECTION - - -0-4 -0 - -4-48 -4 DC VOLTAGE V V 0V 4V 0V V 4V 48V 4V CONSTANT CURRENT REGION Note.4 7. ~V 9 ~ V ~ 0V 4.4 ~ 4V 8 ~ 0V. ~ V. ~ 4V 8.8 ~ 48V.4 ~ 4V RATED
More informationLB115S 115W Single Output
Features Small size of 2 x 4 x 1.3 75W convection cooled/115 Watts with 200 LFM Universal Input 90-264Vac Meets EN55015 Conducted EMI Meets IEC61000-3-2 Class C for less than 1 Watt to full power Approved
More informationPower supply CP-T 24/40.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationZWD100PAF. Conformity to RoHS Directive
-SERIES Dual Output W - 225W Features 15 Complies the standard of the harmonics current limiter Worldwide input: 85-265VAC Peak load accommodatable double power: Approximately twice the value of average
More informationZWD100PAF. Conformity to RoHS Directive
SERIES Dual Output W - 225W Features 15 Complies the standard of the harmonics current limiter Worldwide input: 85-265VAC Peak load accommodatable double power: Approximately twice the value of average
More informationModel Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good
XS XS Xsolo 400W-800W solo Ultra-high efficiency 1U size FEATURES Single output: 24V or 48V EN60950 2 nd Edition & EN60601-1 2 nd and 3 rd Edition Ultra high efficiency, >92% Low profile: 1U height (40mm)
More informationHLG-600H IP65 IP67. series. 600W Single Output Switching Power Supply. Features. Applications
600W Single Output Switching Power Supply F 110 M M SELV HLG-600H series IP65 IP67 Features Universal AC input / Full range (up to 305VAC) Built-in active PFC function No load power consumption
More informationPower supply CP-E 12/10.0 Primary switch mode power supply Data sheet
2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer
More informationPower supply CP-E 24/0.75
2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output
More informationIMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet
IMA 1000 Watts Power Supply Series for medical and industrial applications Product data sheet Features 1000 Watts Power Supply Series for medical and industrial applications Safety rated for Medical, Industrial
More informationDoc. EA Model Number:
VPS-030AAC Series / VPS-030AAC 030AAC Highlights & Features VPS-030AAC05, 12, 15, 24 Meet DOE Level VI & ErP 2017 Low touch current. Suitable for type BF applications Detachable AC plug with multiple country
More informationIndustrial Applications Telecom Daracom
ABC200 Series is a family of compact and efficient AC-DC power supplies suited for telecom datacom and many other industrial applications. This family meets the international information technology safety
More information3000W Single Output Power Supply AK V 200A. 0 ~ 200A 3000W 150mVp-p
000W Single Output Power Supply AK-000 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 0% ) Programmable output Current ( 0% ~ 0% ) High efficiency up to % +V /
More informationKattegat JP Groningen, The Netherlands High Efficiency High Power Audio SMPS
Highlights High efficiency Selectable input voltage range Low EMI Features Advanced over current protection Remote controlled operation Low weight: 1,5kg Compact: 200 x 145 x 55mm Fixed output voltage
More informationAll specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.
KEY FEATURES Din Rail Switching Power Supply 180 Watt with 18CFM FAN for 12V to 48V Output Voltage 150 Watt with 30CFM FAN for 5V Output Voltage High Efficiency up to 93% Universal Input: 90-264 VAC Low
More informationMTC Series 15 W AC/DC Switching Power Supply Module Medical
Switching Power Modules for PCB Mounting Fully Encapsulated Plastic Case Universal Input Range 90-264VAC, 47-440 Hz Regulated Low Ripple and Noise & High Efficiency Isolation class II UL60601-1 / IEC60601-1
More informationElectrical Specifications
450 Watt Medical Features 4 x 6.5 x 1.61 inches Approval to EN60601 3rd Edition Dual Fusing Current Sharing Option Cover and Fan Options Peak Power Capability Class B EMI & Medical (BF) Safety Approvals
More information22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection
Relays 22 Technical Data...1 Specifications...2 Model Number Structure - Relays...3 Model Number Selection... 4-5 Electrical Characteristics...6 Accessories...7 Dimensions...8 Instructions...10 Safety
More information3000W Single Output Power Supply AK V 24V 250A 200A 125A 0 ~ 250A 0 ~ 125A 3000W 0 ~ 200A. 3000W 150mVp-p 3000W
Single Output Power Supply AK-000 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 0% ) Programmable output Current ( % ~ 0% ) High efficiency up to % +V / 0.A auxiliary
More informationModel Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good
XS XS 400W-800W solo Ultra-high efficiency 1U size FEATURES Single output: 24V or 48V EN60950 2 nd Edition & EN60601-1 2 nd and 3 rd Edition Ultra high efficiency, >92% Low profile: 1U height (40mm) Convection
More informationEfficiency (typ.) (Range) Load. Output Current Input Current Reflected Ripple
FEATURES Highest Power Density 1" x 1" x 0.4" Shielded Metal Package Ultra Wide 4:1 Input Range Excellent Efficiency up to % Operating Temp. Range - C to + C Optional Heatsink I/O-isolation Voltage 10VDC
More informationDSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details
120 Watts xxx Series Ultra Slim Design - 32 mm 150% Peak Load for 3 seconds Ambient Operation from -25 C to +70 C Full Load at 60 C (24V/48V) High Efficiency - Up to 92% Volt-Free Contact for OK Selectable
More informationPower supply CP-E 48/5.0 Primary switch mode power supply Data sheet
2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated
More informationIMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet
IMA 600 Watts Power Supply Series for medical and industrial applications Product datasheet 600 Watts Power Supply Series for medical and industrial applications Features Safety rated for Medical, Industrial
More informationElectrical Specifications
300 Watt Industrial Features 3 x 5 x 1.5 inches Wide range AC input EMI Class B CE marked to LVD Class 1 & Class 2 options Input Voltage Input Frequency Electrical Specifications 90-264 VAC/120-390 VDC,
More informationC B. Models. Models 2MOPP
AC/DC Medical Power Supplies High power density 3" x 5" open frame medical power supply 450 Watt with forced air cooling 320 Watt convection cooled without derating up to 50 C Medical certification to
More informationNLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26
Total Power: 65-75 W Input Voltage: 85-264 VAC 120-370 VDC* # of Outputs: Single, dual, triple SPECIAL FEATURES Universal Input 3 x 5 footprint Low profile fits 1U applications EN61000-3-2 compliance option
More informationLCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans
LCL Series SIngle Output Industrial Supplies High Efficiency Low Cost 150 W Convection Cooled 300 W & 500 W with Internal Fans Outputs form 12 V to 48 V 3 Year Warranty The LCL series is a low cost chassis
More information