Download "WARNING. Disconnect the inverter from all the external power sources before service!"

Transcription

1

2

3

4 WARNING Disconnect the inverter from all the external power sources before service! Do not touch live parts until 10 minutes after disconnection 10 min from the sources! Hot surface! May exceed 60! Danger to life due to high voltages! Only qualified personnel can open and service the product! Check user manual before service! II

5

6

7

8

9

10

11

12

13

14 A B C D

15 L2 L1 L3 SG60KTL PE IT Transformer L2 N L1 L3 SG60KTL PE TT Transformer L2 PEN L1 L3 SG60KTL PE TN-C Transformer Transformer L2 N PE L1 L3 SG60KTL PE TN-C-S L2 N PE L1 L3 SG60KTL PE TN-S Transformer

16

17

18 Inversion circuit DC DC EMI Filter DC bus Inversion circuit AC Reactor Relay AC EMI Filter L1 L2 L3 N PE Fan Auxiliary power circuit DSP+CPLD LCD/RS485 Junction box DC + - L1 L2 L3 N DC switch DC SPD DC fuse Current detection + - DC In L1 L2 L3 N PE

19

20 S(KVA) Temperature Derating Curve(Vac=400V) 1.1Pn 60 Vmpp=600V 55 Vmpp=710V 50 Vmpp=850V Ambient Temperature [ C] P n Working area V min 215V V max

21 Start 1 Unpacking and Inspection 2 Read User Manual Install immediately? No 3 Storage 4 Yes Select mounting location 5 Move inverter 6 Install inverter 7 Electrical connection 8 9 Check before commissioning Commissioning 10 Troubleshooting Success? No Yes End

22

23 385mm 770mm 1160mm

24 max. Input current GRID-CONNECTED INVERTER 1 Type SG60KTL S/N DC-Input min. MPP voltage max. MPP voltage max. Input voltage Isc PV 570V 850V 1000V 120A 140A 2 AC-Output Rated output power Rated output voltage Rated output frequency Max. Output current Power Factor Range Safety Class Enclosure Ambient temperature Overvoltage Category 60000W 3/N/PE,230V/400V 50Hz/60Hz 96A Adj. 0.8 overexcited underexcited Ⅰ IP III[MAINS], II[PV] 3 Grid Monitoring: VDE SUNGROW POWER SUPPLY CO., LTD. MADE IN CHINA 4

25 A B C D 14 E F G H

26 (

27 Flammable wall material Flammable material or gas near the installation

28 Forward Backward Upside down Max. ambient temperature: +60 C Min. ambient temperature: -25 C Relative humidity: 0-100%

29 Direct sunlight Rainfall Snow 冷空气 热空气 600mm 800mm 800mm 600mm

30 M4X7 3-26X M10

31 Install backplate E F C B A D

32 Hang inverter Install Inverter cap

33 Mark positions Drill holes Install backplate

34 Hang inverter Install Inverter cap

35 Front view

36 Bottom view 10 9

37 L1 L2 L3 N PE Inverter 1 Inverter 2 Inverter n

38 U2 V2 W2 N Low-voltage side High voltage side U1 V1 W1 MV transformer Inverter 1 Inverter 2 Inverter n

39 0.48 Max. grid impedance [Ohm] AC voltage without loads [V] 265

40 A C B D PE L1 L2 L3 N

41

42 90 A(apex)

43 PV input Inverter inside MPPT

44 β Open-circuit voltage threshold(v) Altitude[m]

45 7mm Positive Crimp Contact Negative Crimp Contact

46 Positive Insulator Cable Gland Crimp Contact Negative Insulator Cable Gland Crimp Contact OFF ON

47 - - + DC DC + -

48 Inverter 1 Inverter 2 Inverter n PV Arrays 1 PV Arrays 2 PE PE PE PV Arrays n Mounting Frame of PV arrays Equipotential cable Grounding of PV Power System Inverter AC Circuit Breaker L1L2 L3N L1 L2 L3 N PE AC Grounding Electrode Grounding of Inverter AC Side

49 M6

50 Ω Configuration circuitboard 120Ω terminating resistor switch Ethernet 1A B Ethernet GND 2 Ethernet Port OFF ON Default A B GND RS485 bus terminal RS485 interface

51 Inverter RS485 IN OUT SolarInfo Logger RS485 SolarInfo Logger RS485 PC RS232 Communication of single inverter RS converter RS485 RS232 PC RS232 RS485in RS485out 120ohm Ω

52 Inverter 1 RS485 IN OUT Inverter 2 RS485 IN OUT Inverter n RS485 IN OUT SolarInfo Logger RS Ω Shielding layer is grounded SolarInfo Logger RS485 PC RS232 Multiple inverters in daisy chain 120Ω RS converter RS485 RS232 PC RS232 n>15 RS485in RS485out 120ohm 120ohm RS485in RS485out 120ohm A B GND RS485in RS485out 120ohm 120ohm A B GND

53

54 RS485 B A TX- TX+ RX- RX+ RS232 RJ45 plug RJ45 Port Corresponding Relationship Between Cables and Pins: Pin 1: White-orange; Pin 2: Orange; Pin 3: White-green; Pin 4: Blue; Pin 5: White-blue; Pin 6: Green; Pin 7: White-brown; Pin 8: Brown RS485+ A RS485- B Pin 3 and Pin 6 are used for communication. - Pin 3 to RS485- B - Pin 6 to RS485+ A

55 RS485 Pin 3 Pin 6 TX- TX+ RX- RX+ RS232

56

57 Countries GB DE FR IT ES BE AT DK AU GR CZ NL PT CN SE RO TH TK AE IR HN KR ZAF CHL BRA TPE IND other Warning! Only qualified personnel rare allowed to adjust following parameters. Improper settings may cause damage to the inverter! GR Grid codes GR_L GR_IS

58 DE Grid codes LV MV TK Grid codes AG YG TH Grid codes 220V 230V Other Grid codes 50Hz 60Hz Pro-Stage Single-stage Multi-stage

59 Time YY/MM/DD Date: 15/01/31 Time: 10:30:55 Set t i ng conf i r mat i on Count r i es Ot her Pr o- st age Si ngl e- st age Gr i d codes MV Dat e 2015/ 01/ 31 Conf i r m above set t i ngs? 001 P(%) t P-ac E-day E-tot State kw kw 15.6 kwh h kwh kw Run h 110.0% 2015/01/31 10:30

60

61

62

63

64

65

66

67

68 1 2 2

69

70

71 001 P(%) t % P-ac E-day E-tot State kwh kw kw kwh kw Run 2015/01/31 10:30 ESC ENTER Menu 50% Run-inform His-inform Start/Stop Set-param ENTER ENTER His-inform Start/Stop Set-param Flt-record Evt-record ENTER Run-record Energy-record Start Stop Sys-param Run-param Pro-param Com-param ENTER ENTER ENTER ENTER Sys-param Languages Time Energy-adj Load default Firmware version Run-param P-Q param Time param Derating param Iso param LVRT param HVRT param Countries GB DE FR IT ES AT AU CZ BE DK GR NL PT CN SE RO AE IR TH TK HN KR ZAF CHL BRA TPE IND other Com-param Addr 001 h h

72 Device address 001 Power curve Icon &active power limit P(%) t % P-ac E-day E-tot State kw kw h 15.6 kwh kwh kw Run h 2015/01/31 10:30 Present power Today s energy Total energy Inverter state Time

73 Current fault P1/1 1 GRID %

74 DC power input 00000W DC Vdc[V] Idc[A] 10.0 Pdc[W] DC-1: 4.23A DC-6: 4.23A DC-11: 6.25A DC-2: 4.23A DC-7: 4.23A DC-12: 6.25A DC-3: 4.23A DC-8: 4.23A DC-13: 6.25A DC-4: 4.23A DC-9: 4.23A DC-14: 6.25A DC-5: 4.23A DC-10: 4.23A L1 L2 L3 Vac[V] Iac[A] Pac[W] F[Hz] CO2-reduce E-month h-total T-today Temp ISO 6kg 10kWh 1h 63min 25.0 C 30kΩ P-W S-Va Country Grid code 100W 130VA DE LV

75 His-inform Run- r ecor d P1/ / 01/ 21( 30) Flt-record Evt-record Run-record Energy-record Run- r ecor d T4 2015/ 01/ 21 P001/ / 01/ 21 18: 50 DC power input 00000W DC Vdc[V] Idc[A] 10.0 Pdc[W] L1 L2 L3 Vac[V] Iac[A] Pac[W] F[Hz] P-W 100W CO2-reduce 6kg S-Va 130VA E-month 10kWh Country DE h-total 1h Grid code LV T-today 63min Temp 25.0 C ISO 20000kΩ Fl t - r ecor d P 1/ / 01/ 31 10: 16: 10 [ 0008] / 01/ 31 10: 16: 10 [ 0008] / 01/ 31 10: 16: 10 [ 0008] / 01/ 31 10: 16: 10 [ 0008] / 01/ 31 10: 16: 10 [ 0040]

76 Evt-record P 1/ /01/31 10:16:10 Fault Energy-record Power curve Daily energy histogram Monthly energy histogram Annual energy histogram P(%) 110 Power cur ve 2015/01/31 P1/ t

77 Dai l y ener gy hi st ogr am E(kWh) /01 P1/ t Mont hl y ener gy hi st ogr am E(kWh) P1/ Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov now t E(KWh) Annual energy histogram P1/ t Start/Stop Start Confirm start inverter? Stop Confirm stop inverter?

78 Set-param Password: Set-param Sys-param Run-param Pro-param Com-param Sys-param Languages Time Energy-adj Load default Firmware version

79 Languages Auto English Deutsch Francaise Italia 中文 Time YY/MM/DD Date: 15/01/31 Time: 10:30:55

80 Energy-adj +0000kWh Load default Confirm resume setting? Firmware version Device Type: SG60KTL SN: A Ver: DSP_SG60KTL_V11_V1_A_M LCD_SG60KTL_V03_A_M

81 Run-param P-Q param Time param Derating param Iso param LVRT param HVRT param

82 KΩ KΩ

83 P-Q Param P-W limits 110.0% Rate limit [ON/OFF] Power raise 100%/min Power decline 6000%/min Fault slowup [ON/OFF] Slowup rate 10%/min P-Q param Q-Var switch [OFF] RF Q-Var limits %

84 Run- par am- Q( P) Upper PF Cap Lower Power % Lower PF I nd Upper Power % COS Ф Upper PF Cap P1 General Q(P) curve COS Ф Default Q(P) curve Capacitive P/Pn 1 Lower Power Power Upper Power Upper PF Cap =1 Lower Power =50% P1 Power Upper Power =100% P/Pn L2 Inductive Lower PF Ind P2 Lower PF Ind =0.9 P2

85 Run-param-Q(U) Lower Q/Sn Ind 050.0% Upper Q/Sn Cap 050.0% Lower U Limit 095.0% Upper U Limit 115.0% Run-param-Q(U) U1 Limit 095.0% U2 Limit 105.0% Hysteresis 3.0% Q/Sn Upper Q/Sn Ind P1 Hysteresis P2 U2 Limit Upper U limit Grid Lower U limit U1 Limit P3 voltage Hysteresis Lower Q/Sn Cap P4

86 Run-param-Q(P) P3/3 PA 020.0% PB 050.0% PC 100.0% Pf max Uin 105.0% Uout 100.0% >

87 Default Curve Inductive Deviation Capacitive No Regulation cos = ± 0,98 Depends on the capacity of the inverter. Run- par am- Q( U) P3/ 4 V2i % V1i % V1s % V2s % Qmax % Pi n % Run- par am- Q( U) P4/ 4 Pout % Cur ve [ A]

88 A B Inductive A B Inductive - - Capacitive C Capacitive C D D A: Default B P-Q param Save P-W setting [ON/OFF] Save Q-Var setting [ON/OFF] Time-param Standby time Recovery time 020s 000s

89 Derating param Fre-Derating F1 [ON/OFF] 50.00Hz P1 100% F Hz P2 100% F Hz P3 100% ISO param ISO [ON/OFF] ISO pro value 30kΩ LVRT param LVRT [ON/OFF] LVRT kf 02 LVRT normal volt 195.5V LVRT T S LVRT tolera volt 34.5V LVRT T2 0.62S

90 HVRT param HVRT [ON/OFF] HVRT kf 010 HVRT normal volt 110.0% HVRT T S HVRT tolera volt 130.0% HVRT T S Countries GB DE FR IT ES BE AT DK AU GR CZ NL PT CN SE RO TH TK AE IR HN KR ZAF CHL BRA TPE IND other

91 GR Grid codes DE Grid codes TK Grid codes GR_L GR_IS LV MV AG YG

92 TH Grid codes Other Grid codes 220V 230V 50Hz 60Hz Pro-Stage Single-stage Multi-stage Pro-param Single Vgrid-max 276.0V Vgrid-min 184.0V Fgrid-max 51.50Hz Fgrid-min 49.80Hz Pro-param Multi Pro-param Multi I-Max-V.grid 000.0V I-Max-V.time s II-Max-V.grid 000.0V II-Max-V.time s I-Min-V.grid 000.0V I-Min-V.time s II-Min-V.grid 000.0V II-Min-V.time s Pro-param Multi Pro-param Multi I-Min-F.grid 00.00Hz I-Max-F.grid 00.00Hz I-Min-F.time s I-Max-F.time s II-Min-F.grid 00.00Hz II-Max-F.grid 00.00Hz II-Min-F.time s II-Max-F.time s Ⅰ Ⅰ Ⅰ Ⅰ

93 Ⅱ Ⅱ Ⅱ Ⅱ Ⅰ Ⅰ Ⅱ Ⅱ Ⅰ Ⅰ Ⅱ Ⅱ Ⅰ Ⅰ Ⅱ Ⅱ Ⅰ Ⅰ Ⅱ Ⅱ Ⅰ Ⅰ Ⅱ Ⅱ Ⅰ Ⅰ Ⅱ Ⅱ Pro-recover Vmax-recover 240.0V Vmin-recover 220.0V Fmax-recover 50.10Hz Fmin-recover 49.50Hz

94 Setting confirmation Countries Pro-stage Grid codes Other Single-stage MV Date 2015/01/31 Confirm above settings? Com-param Modbus param Uart param Modbus param Addr 001 Uart param Baud [9600] Parity [ NO ] Stop bit [1]

95 Set - par am Passwor d: Advanced settings PVS Detect 10min Grid Max-v Unbalance PVS Det ect ON OFF Reset Advanced set t i ngs Passwor d:

96 Advanced settings PVS Detect 10min Grid Max-v Unbalance 10min Max-V 10min Max-v [ON/OFF] Pro-value 000.0V Rec-value 000.0V Grid Unbalance Grid Unbalance Amplitude Pro-time [ON/OFF] 10% 05.00S

97

98 Ⅲ +

99

100

WARNING. Disconnect the inverter from all the external power sources before service!

WARNING. Disconnect the inverter from all the external power sources before service! WARNING Disconnect the inverter from all the external power sources before service! Do not touch live parts until 10 minutes after disconnection 10 min from the sources! Hot surface! May exceed 60! Danger

More information

10 min A B C D TN-C TN-C-S IT Transformer L1 L2 L3 PEN Transformer L1 L2 L3 N PE Transformer PE L1 L2 L3 PE SG36KTL-M PE SG36KTL-M SG36KTL-M 1 6 7 2 3 4 5 6 8 525 267.7 240 740 690 3 1 1 2 2

More information

WARNING. Disconnect the inverter from all the external power sources before service!

WARNING. Disconnect the inverter from all the external power sources before service! WARNING Disconnect the inverter from all the external power sources before service! Do not touch live parts until 10 minutes after disconnection 10 min from the sources! Hot surface! May exceed 60! Danger

More information

Conext CL-60 Inverter Active and Reactive Power Control and LVRT

Conext CL-60 Inverter Active and Reactive Power Control and LVRT Conext CL-60 Inverter Active and Reactive Power Control and LVRT http://solar.schneider-electric.com 976-0381-01-01/B March 2017 Application Note EXCLUSION FOR DOCUMENTATION UNLESS SPECIFICALLY AGREED

More information

Conext CL125 Inverter - Active and Reactive Power Control and LVRT/HVRT

Conext CL125 Inverter - Active and Reactive Power Control and LVRT/HVRT Conext CL125 Inverter - Active and Reactive Power Control and LVRT/HVRT http://solar.schneider-electric.com 976-0406-01-01/A May 2018 Application Note EXCLUSION FOR DOCUMENTATION UNLESS SPECIFICALLY AGREED

More information

Conext CL-60 PV Inverter

Conext CL-60 PV Inverter Conext CL-60 PV Inverter Owner s Guide 975-0768-01-01 Rev G 12-2017 CL-60E CL-60JP CL-60A http://solar.schneider-electric.com Conext CL-60 PV Inverter Owner s Guide http://solar.schneider-electric.com

More information

Technical Information SMA SOLID-Q 50 / PRO 60 Modbus Interface

Technical Information SMA SOLID-Q 50 / PRO 60 Modbus Interface Technical Information SMA SOLID-Q 50 / PRO 60 Modbus Interface SMASOLID-Q-Modbus-TI-en-10 Version 1.0 ENGLISH Legal Provisions The information contained in these documents is property of SMA New Energy

More information

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS INSTRUCTION MANUAL BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS 1/23 More information than that reported

More information

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W Page 2 / 16 INDEX: GENERAL TYPES ACESSORIES AND OPTIONS INSTALLATION WIRING DIAGRAMS CONNECTING TERMINALS DIAGRAMS WIRING DIAGRAM DESCRIPTION WORKING DESCRIPTION AND KEYBOARD WORKING DESCRIPTION AND PROGRAMMING

More information

Power Quality and Energy Measurement PEM735

Power Quality and Energy Measurement PEM735 Power Quality and Energy Measurement PEM75 PEM75_D00084_01_D_XXEN/01.2015 Power Quality and Energy Measurement PEM75 class A Product description The digital universal measuring device PEM75 is suited for

More information

Operation and Installation manual

Operation and Installation manual Operation and Installation manual SOLIVIA 15 EU G4 TL and SOLIVIA 20 EU G4 TL EU ENGLISH This manual is subject to change. Please check our website at www.solar-inverter.com for the most up-to-date manual

More information

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions ELECTRONIC SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING

More information

TECHNICAL DATA FRONIUS SYMO ( M, M, M, M, M)

TECHNICAL DATA FRONIUS SYMO ( M, M, M, M, M) TECHNICAL DATA FRONIUS SYMO (10.0-3-M, 12.5-3-M, 15.0-3-M, 17.5-3-M, 20.0-3-M) INPUT DATA SYMO 10.0-3-M SYMO 12.5-3-M SYMO 15.0-3-M SYMO 17.5-3-M SYMO 20.0-3-M Max. input current (I dc max 1 / I dc max

More information

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INSTRUCTIONS MANUAL IM831-U v0.92 HRI-R40W sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INDEX: GENERAL TYPES ACESSORIES AND OPTIONS

More information

ZHUHAI PILOT TECHNOLOGY CO., LTD.

ZHUHAI PILOT TECHNOLOGY CO., LTD. SPM32 Multifunctional Power Meter SPM32 Multifunction Power Meter Installation & Operation Manual V1.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. Danger and warning! This device can be installed only by professionals.

More information

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3 CHAPTER INSTALLATION 2 AND WIRING Contents of this Chapter... Ambient Conditions..............................2 2 Storage Conditions...............................2 2 Installation.....................................2

More information

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

ENA33LCD. Power line analyzer. User and service manual.   Obrezija 5 SI-1411 Izlake ENA33LCD Power line analyzer User and service manual version 2.9 (FW version 6.8 and newer) ETI, d.o.o. Obrezija 5 SI-1411 Izlake www.etigroup.eu/products-services 1. Front control panel and terminal plate

More information

Power Quality and Energy Measurement PEM533

Power Quality and Energy Measurement PEM533 Power Quality and Energy Measurement _D00013_02_D_XXEN/11.2014 Power Quality and Energy Measurement 0.5 S Product description The digital universal measuring device is suited for measuring and displaying

More information

/ The allrounder with maximum yield. / Smart Grid Ready. / WLAN interface

/ The allrounder with maximum yield. / Smart Grid Ready. / WLAN interface / Battery Charging Systems / Welding Technology / Solar Electronics FRONIUS IG PLUS / The allrounder with maximum yield. / Fronius MIX technology / HF transformer switchover / PC board replacement process

More information

/ PC board replacement. / Smart Grid Ready TECHNICAL DATA FRONIUS SYMO (3.0-3-S, S, S, M, M, M)

/ PC board replacement. / Smart Grid Ready TECHNICAL DATA FRONIUS SYMO (3.0-3-S, S, S, M, M, M) solarpowerpanels.net.au Brisbane - Gold Coast - Sunshine Coast 0431 094 756 / Perfect Welding / Solar Energy / Perfect Charging FRONIUS SYMO / Smarter, Lighter, More Flexible N 100 W E 0 S / SnapINverter

More information

SUPPLY NETWORK ANALYZER CVM-96 SERIES

SUPPLY NETWORK ANALYZER CVM-96 SERIES SUPPLY NETWORK ANALYZER CVM-96 SERIES (Power Demand) INSTRUCTION MANUAL ( M 981 326 / 00B - GB) (c) CIRCUTOR S.A. ----- Supply network analyzer CVM-96 ------ User's manual --- Page No. 1 CVM-96 SUPPLY

More information

Power Quality and Energy Measurement PEM575

Power Quality and Energy Measurement PEM575 Power Quality and Energy Measurement _D00016_03_D_XXEN/12.2015 Power Quality and Energy Measurement Product description The digital universal measuring device is suited for measuring and displaying electrical

More information

8730 Electric Parameter Meter User manual

8730 Electric Parameter Meter User manual 8730 Electric Parameter Meter User manual ( Ver 2.10 ) Qingdao QINGZHI Instruments Co., Ltd. Address: 5th Floor, Building 1, Shenghe Building, No.58 Shandongtou Road, Laoshan District, Qingdao, China,

More information

ISOMETER IRDH575. Approvals

ISOMETER IRDH575. Approvals Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation

More information

Power Quality and Energy Measurement PEM575

Power Quality and Energy Measurement PEM575 Power Quality and Energy Measurement _D00016_00_D_XXEN/06.2013 Power Quality and Energy Measurement Product description The digital universal measuring device is suited for measuring and displaying electrical

More information

DPF-MAC Auto power factor controller

DPF-MAC Auto power factor controller Digital Electric& Electronics System DPF-MAC Auto power factor controller MULTI POWER FACTOR AUTOMATIC MULTI POWER FACTOR AUTOMATIC Introduction DPF-MAC increases usage efficiency by controlling the power

More information

03 / Data Sheet. PIKO-Inverter

03 / Data Sheet. PIKO-Inverter 03 / 2013 EN Data Sheet PIKO-Inverter 3.0 3.6 4.2 5.5 7.0 8.3 10.1 Table of content 4 Overview technical data Inverter single-phase 5 Inverter PIKO 3.0 5 Inverter PIKO 3.6 Inverter three-phase 6 Inverter

More information

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready / Battery Charging Systems / Welding Technology / Solar Electronics FRONIUS SYMO / Maximum flexibility for the applications of tomorrow. / PC board replacement process / Mounting system / WLAN interface

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Installation and Operating Instructions. Power IT Power Factor Controller RVC Installation and Operating Instructions Power IT Power Factor Controller RVC Table of contents Page 1. Read this first... 3 About this Instruction Manual... 3 Safety... 3 Electromagnetic compatibility...

More information

MULTIFUNCTION GRAPHICAL UNIT MGU 800

MULTIFUNCTION GRAPHICAL UNIT MGU 800 MULTIFUNCTION GRAPHICAL UNIT MGU 800 For display, recording and evaluation of process instruments signals (level, temperature, pressure, etc.) 3.5" TFT display, multi-language menu Variety of possible

More information

ABB solar inverters. User s manual PVS-JB-8-M junction box with monitoring for PVS800 central inverters

ABB solar inverters. User s manual PVS-JB-8-M junction box with monitoring for PVS800 central inverters ABB solar inverters User s manual PVS-JB-8-M junction box with monitoring for PVS800 central inverters List of related manuals Inverter hardware manuals and guides PVS800-57 central inverters (100 to 500

More information

SUPPLY NETWORK ANALYZER

SUPPLY NETWORK ANALYZER SUPPLY NETWORK ANALYZER CVM-144 SERIES (Ethernet) (Ver 6.11 and higher) INSTRUCTION MANUAL (M98203401-03-06A) CIRCUTOR S.A. ----- Supply network analyzer CVM-144 ------ User's manual --- Page No. 1 CONTENTS

More information

PEM353. Universal measuring device

PEM353. Universal measuring device 353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities

More information

Integrated servo motor

Integrated servo motor R88E-AECT@, R88S-EAD@ Integrated servo motor Motor and drive integrated for space optimization Wide range of motors from 2.55 Nm to 25 Nm 3000 rpm rated speed Peak torque 300% of rated torque IP65 protection

More information

3-phase meter with direct connection and pulse or Modbus RS485 output

3-phase meter with direct connection and pulse or Modbus RS485 output 87045 LIMOGES Cedex Telephone: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 3-phase meter with direct connection and CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...

More information

Single phase meter with direct connection and pulse or Modbus RS485 output

Single phase meter with direct connection and pulse or Modbus RS485 output 87045 LIMOGES Cedex Telephone: +33(0)5 55 06 87 87 Fax: +33(0)5 55 06 88 88 Single phase meter with direct connection CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...

More information

Installation Instructions and Reference Handbook. Installation instructions

Installation Instructions and Reference Handbook. Installation instructions Installation Instructions and Reference Handbook Multi-instrument MIB 7000/7000C/7020 4189320016B (UK) DEIF A/S Product information Installation instructions Basic operation DEIF A/S, Frisenborgvej 33

More information

PLA 33. Power line analyzer. User and service manual. version 2.4

PLA 33. Power line analyzer. User and service manual. version 2.4 PLA 33 Power line analyzer User and service manual version 2.4 Content. Front control panel and terminal plate...3 7.2.2. System frequency setting...0 2. Device description...4 7.2.3. Password protection...0

More information

Modbus communication module for TCX2: AEX-MOD

Modbus communication module for TCX2: AEX-MOD Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation

More information

DEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description

DEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description Description of options Option H3 Serial communication Profibus DP Multi-line 2 version 2 4189340279I SW 2.42.X Description of option Functional description DEIF A/S Parameter table Data tables DEIF A/S,

More information

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols

More information

Brief description of KR 15 controllers

Brief description of KR 15 controllers Brief description of KR 15 controllers E N E R G Y R E C O V E R Y Page 2 Page 4 Page 5 Page 6 Page 9 1. Function of the controller 2. Terminal connections 3. Technical data 4. Initial operation 5. Manual

More information

General Specifications FECA-TE /2010. Phone: Fax: Web:

General Specifications FECA-TE /2010. Phone: Fax: Web: General Specifications FECA-TE-117 06/2010 1. Standard Specifications 1) Three-phase 230V series Output ratings Input ratings Braking Item Specifications Type (FRN C1S-2U) F12 F25 F50 001 002 003 005 Nominal

More information

TT-SI MHz DIFFERENTIAL PROBE

TT-SI MHz DIFFERENTIAL PROBE TT-SI 9110 100MHz DIFFERENTIAL PROBE USER S MANUAL This probe is in compliance with IEC-1010.1, IEC - 1010. 2-031 CATⅢ, Pollution Degree 2. 1. Safety Terms and Symbols Terms appear in this manual: WARNING.

More information

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA

More information

Mounting Instructions / Manual MV1171

Mounting Instructions / Manual MV1171 Mounting Instructions / Manual MV1171 POWER FACTOR Controller ESTAmat MH-N Vishay Electronic GmbH ESTA Capacitors Division Revision: 19-April-2011 Hofmark-Aich-Strasse 36 84030 Landshut, Germany Phone

More information

Analogue temperature controllers

Analogue temperature controllers Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications

More information

EE Grid-Tied PV Systems. Y. Baghzouz Spring 2011

EE Grid-Tied PV Systems. Y. Baghzouz Spring 2011 EE 495-695 Grid-Tied PV Systems Y. Baghzouz Spring 2011 Applicable Codes & Standards Most Important: NEC IEEE Std 1547 Summary of Content of NEC NEC (Voltage Drop Requirement) NEC requires that the voltage

More information

External RF Driver. Electrical Driver for AOTF-crystal. Instruction Manual

External RF Driver. Electrical Driver for AOTF-crystal. Instruction Manual External RF Driver Electrical Driver for AOTF-crystal Instruction Manual Table of Contents 1 General... 3 2 Compliance... 3 3 Labeling... 4 4 Interface... 5 4.1 Front Panel... 5 4.2 Back Panel... 6 4.2.1

More information

Metasys Integrator Power Measurement Ltd. Application

Metasys Integrator Power Measurement Ltd. Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date January 19, 2006 APPLICATION NOTE Metasys Integrator Power Measurement Ltd. Application lntroduction Page

More information

/ The allrounder with maximum yield. Technical data: Fronius IG Plus (25 V-1, 30 V-1, 35 V-1, 50 V-1, 55 V-1, 60 V-1)

/ The allrounder with maximum yield. Technical data: Fronius IG Plus (25 V-1, 30 V-1, 35 V-1, 50 V-1, 55 V-1, 60 V-1) / Battery Charging Systems / Welding Technology / Solar Electronics FRONIUS IG PLUS / The allrounder with maximum yield. / Fronius MIX concept / HF transformer switchover / PC board replacement concept

More information

DS2 series servo drive

DS2 series servo drive DS2 series servo drive Manual WUXI XINJE ELECTRIC CO., LTD. Data No.: SC209 20110412 1.0 2 Safety notes Confirmation Do not use the drivers that are broken, lack of parts or wrong types. Installation Make

More information

COUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet

COUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet INSTRUCTION MANUAL COUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet EN countis e27 countis e28 - mid www.socomec.com/ en/countis-e2x EN Contents 1. Documentation.... 3 2. Hazards and warnings...

More information

TORKEL 900-series Battery Load Unit

TORKEL 900-series Battery Load Unit TORKEL 900-series Batteries can be tested in service Dynamic discharge technology full power at all voltages Safety in all details, e.g. detection of blocked airflow Real time monitoring during test Easy

More information

Tel: Fax:

Tel: Fax: Grid Tie Solar Inverter Operator's Manual SG-4000 1 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS To reduce the risk of electrical shock and to ensure safe installation and operation of Grid Tie

More information

TORKEL 900-series Battery Load Unit

TORKEL 900-series Battery Load Unit Batteries can be tested in service Dynamic discharge technology full power at all voltages Safety in all details, e.g. detection of blocked airflow Real time monitoring during test Quick report Easily

More information

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution

More information

Programmable AC Voltage Transducer MT416

Programmable AC Voltage Transducer MT416 Programmable AC Voltage Transducer MT416 RMS AC voltage or frequency measurements Voltage auto measurements up to 600 V L-N Frequency measurement 16 400 Hz AC or universal wide auiliary power 24 300 Vdc,

More information

General Specifications

General Specifications General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter

More information

Digital Multifunction Meter - RISH Integra 2000

Digital Multifunction Meter - RISH Integra 2000 Features Four line graphic LCD display 1+ parameters Fast communications Customer configurable Easy to use Output options: 4 x -1mA 4 x 4-2mA 1 or 2 energy pulses Panel mounted Neutral current measurement

More information

TECHNICAL PRODUCT DATASHEET

TECHNICAL PRODUCT DATASHEET FORM-ENG-0018 REV A 06-02-03 ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR OEM DISTRIBUTION ONLY TECHNICAL PRODUCT DATASHEET High Density PDM 21 Output / 10

More information

SFP-SW10100-R-TP 10/100/1000 BASE-T Copper SFP Transceiver

SFP-SW10100-R-TP 10/100/1000 BASE-T Copper SFP Transceiver SFP-SW10100-R-TP 10/100/1000 BASE-T Copper SFP Transceiver PRODUCT FEATURES Up to 1.25 Gb/s bi-directional data links Hot-pluggable SFP footprint Low power dissipation(1.05w typical) Compact RJ-45 assembly

More information

7P Series - Surge Protection Device (SPD) Features 7P P P

7P Series - Surge Protection Device (SPD) Features 7P P P Features 7P.09.1.255.0100 7P.01.8.260.1025 7P.02.8.260.1025 SPD Type 1+2 Surge arrester range - single phase system / three phase system Surge arresters suitable in low-voltage applications in order to

More information

General Specifications

General Specifications General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with

More information

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready / Battery Charging Systems / Welding Technology / Solar Electronics Fronius Symo / Maximum flexibility for the applications of tomorrow. / PC board replacement process / Mounting system / WLAN interface

More information

Instruction Manual. General application Inverter. IMO idrive2 XKL

Instruction Manual. General application Inverter. IMO idrive2 XKL Instruction Manual General application Inverter IMO idrive2 XKL Thank you for purchasing our idrive2 XKL series of inverters. This product is designed to drive a three-phase induction motor. Read through

More information

TECHNICAL DATASHEET #TDAX ISOLATED DUAL CHANNEL UNIVERSAL SIGNAL CONVERTER

TECHNICAL DATASHEET #TDAX ISOLATED DUAL CHANNEL UNIVERSAL SIGNAL CONVERTER Preliminary TECHNICAL DATASHEET TDAX130540 ISOLATED DUAL CHANNEL UNIVERSAL SIGNAL CONVERTER 2 Analog (Bipolar), Resistive, Digital, Frequency (RPM) or PWM Signal Inputs Encoder Input Magnetic Pick Up Input

More information

IP1 Datasheet PWM OUTPUT WITH SINGLE CHANNEL ADC MODULE FEATURES DESCRIPTION CONNECTOR DETAILS

IP1 Datasheet PWM OUTPUT WITH SINGLE CHANNEL ADC MODULE FEATURES DESCRIPTION CONNECTOR DETAILS PWM OUTPUT WITH SINGLE CHANNEL ADC MODULE FEATURES 1 PWM Output (3.3V) 0 Hz 1 khz Single Channel 3.3V 12-bit ADC input for voltage sensing Optional automated PWM adjustment based on input voltage for standalone

More information

Digital Clamp Meter Model: &

Digital Clamp Meter Model: & Digital Clamp Meter Model: 72-7224 & 72-7226 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,

More information

FCR 06, FCR 12. Power factor correction controller. User and service manual

FCR 06, FCR 12. Power factor correction controller. User and service manual FCR 06, FCR 12 Power factor correction controller User and service manual version 2.3 Czech Republic Czech Republic 1 Content 1. Control and signal elements... 3 2. Device description... 4 3. Instruction

More information

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 o RMS AC current or frequency measurements o Current auto range measurements up to 12 A o Frequency measurement range 16 400 Hz

More information

MultiMeter-Pocket CAT III 1000 V

MultiMeter-Pocket CAT III 1000 V 02 10 18 26 34 42 50 58 66 74 82 DE GB NL DK FR ES IT PL FI PT SE AC DC AC DC CAT III 1000 V 90 98 106 114 122 130 138 146 154 162 170 NO TR RU UA CZ EE LV LT RO BG GR ! Read the operating instructions

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Turbine Temperature Test Set

Turbine Temperature Test Set TT1200 Turbine Temperature Test Set USER INSTRUCTION MANUAL BARFIELD M/N TT1200 56-101-00920 Revision D November 7, 2014 BARFIELD, INC. Corporate Headquarters 4101 Northwest 29th Street Miami, Florida

More information

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current

More information

General Specifications

General Specifications General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.

More information

H L G -150H s er i es

H L G -150H s er i es F 110 M M SELV Features : Universal AC input / Full range (up to 305VAC) Built-in active PFC function High efficiency up to 94% Protections: Short circuit / Over current / Over voltage / Over temperature

More information

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional) Temperature Controller with Built-in SSR SB SB General Description SB is a channel temperature controller with Built-in SSR (Solid state relay) designed for flexible heating solutions such as heat trace

More information

TT-SI MHz Active Differential Probe

TT-SI MHz Active Differential Probe INSTRUCTION MANUAL TT-SI 9101 100MHz Active Differential Probe These probe is in compliance with IEC-61010-031 CAT III, Pollution Degree 2 1. Safety Terms and Symbols Terms appear in this manual: WARNING.

More information

RCMS460 and RCMS490 Series

RCMS460 and RCMS490 Series 4 T M RCMS460 and RCMS490 Series Digital Multi-Channel Ground Fault Monitor / Ground Fault Relay Grounded and High-Resistance Grounded AC/DC Systems Technical Bulletin NAE1042060 / 04.2013 BENDER Inc.

More information

800W Single Output Power Supply

800W Single Output Power Supply Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( 0% ~ 05% ) U profile, High power density Constant current limiting High efficiency up

More information

SolarMax TS series 75TS A. Instruction manual

SolarMax TS series 75TS A. Instruction manual SolarMax TS series 75TS A Instruction manual Contents 1 Notes on the present instruction manual 5 1.1 Scope 5 1.2 Target groups 5 1.3 Storage of the documents 5 1.4 Used symbols 5 2 Safety instructions

More information

MACROTEST G1 & G2. I'm pure technology. Touch me, please.

MACROTEST G1 & G2. I'm pure technology. Touch me, please. MACROTEST G1 & G2 I'm pure technology. Touch me, please. 5 Clear answer. Complying o not. Save time! You will take half time! Color Touch Screen with icon intuitive graphics Wi-Fi and USB Power measurement

More information

Operation Manual. imars Grid-tied Solar Inverter. INVT Solar Technology (Shenzhen) Co., Ltd.

Operation Manual. imars Grid-tied Solar Inverter. INVT Solar Technology (Shenzhen) Co., Ltd. Operation Manual imars Grid-tied Solar Inverter INVT Solar Technology (Shenzhen) Co., Ltd. Preface The manual is intended to provide detailed information of product information, installation, application,

More information

HV580 Series Frequency Inverter User Manual

HV580 Series Frequency Inverter User Manual User Manual HNC Electric Limited Contents Contents...2 Chapter 1 Safety Information and Precautions...4 1.1 Safety Information... 4 1.2 General Precautions...7 Chapter 2 Product Information...10 2.1 Designation

More information

Energy Management Energy Analyzer Type EM112

Energy Management Energy Analyzer Type EM112 Energy Management Energy Analyzer Type EM112 Single phase energy analyzer Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Accuracy ±0.5% RDG (current/voltage Direct current measurement

More information

TECHNICAL DATA SHEET. Safety and function tester GLP1-g. Standard model GLP1-g ELECTRICAL SPECIFICATION

TECHNICAL DATA SHEET. Safety and function tester GLP1-g. Standard model GLP1-g ELECTRICAL SPECIFICATION TECHNICAL DATA SHEET Safety and function tester GLP1-g Revision 2.7 / valid from July 2017 Standard model GLP1-g ELECTRICAL SPECIFICATION Supply voltage Mains frequency No load current consumption 110

More information

SELV. 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed

SELV. 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed ID 2000000000 185W Single Output Switching Power Supply SELV series Features : Universal AC input I Full range (up to 305VAC) Built-in active PFC function High efficiency up to 94% Protections: Short circuit

More information

P/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939)

P/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939) TECHNICAL DATASHEET #TDAX022000 Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference (SAE J1939) Features: 1 universal signal input 2 proportional or on/off outputs up to 3 A User

More information

Please note and refer to warning marks which you will find in the unit.

Please note and refer to warning marks which you will find in the unit. Table of contents 1.0 Preface ---------------------------------------------------------------------------------------- 1-1 1-1 Introduction ----------------------------------------------------------------------------

More information

FR-ABR-(H)0.4K to 22K

FR-ABR-(H)0.4K to 22K TRANSISTORIZED INVERTER INSTRUCTION MANUAL HIGH-DUTY BRAKE RESISTOR FR-ABR-(H)0.4K to 22K H Thank you for choosing the Mitsubishi transistorized inverter option unit. This instruction manual gives handling

More information

Ameritron ALS-600 Retrofit ALS-600-LPF Assembly Manual

Ameritron ALS-600 Retrofit ALS-600-LPF Assembly Manual Ameritron ALS-600 Retrofit ALS-600-LPF Assembly Manual FEATURES Automatic band change based on TX frequency. PIN diode QSK RX/TX switch. Temperature controlled FAN for quiet operation. RS-232 serial port

More information

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready / Perfect Welding / Solar Energy / Perfect Charging Fronius Symo / Maximum flexibility for the applications of tomorrow. N 1 W E S / SnapINverter technology / Integrated data communication / SuperFlex

More information

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering METERSUK LTD s a l e s @ m e t e r s. c o. u k 0 1 5 2 4 5 5 5 9 2 9 Series Smart Energy Meter KEY FEATURES Single Phase Metering Single phase metering 4 din modules, Standard DIN rail Format (DIN43880)

More information

Monitoring Electric Network Via Internet

Monitoring Electric Network Via Internet Monitoring Electric Network Via Internet NETWORK ANALYSER let "it" analyse! MPR63 Real time monitoring via internet / intranet Measurement of all electrical parameters Including Harmonics Automatic recording

More information

Output Voltage Output Amps Input Range Max. Iin FL Efficiency (Tb=25 C) O/P Set Point

Output Voltage Output Amps Input Range Max. Iin FL Efficiency (Tb=25 C) O/P Set Point Miniature 4.59 x 2.4 x 0.5. Size High Power Density up to 90.78W/ Inch ³ High Efficiency up to 90.5% at 230VAC (28V) Low Output Noise Metal Baseplate Thermal Protection Over Voltage Protection Current

More information

AC/DC Power Supply Series APPLICATION NOTE

AC/DC Power Supply Series APPLICATION NOTE -175 AC/DC Power Supply Series APPLICATION NOTE 69493 NV175 App note 4.doc Document Number 69493 Page 1 of 17 1. INPUT...3 AC INPUT LINE REQUIREMENTS... 3 2. DC OUTPUT...3 OUTPUT VOLTAGES... 3 REMOTE SENSE...

More information

MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: 47LV. Digital Panel Meters 47 Series Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display

More information

MU110-16R(K) Digital output module 16 channel. User guide

MU110-16R(K) Digital output module 16 channel. User guide MU110-16R(K) Digital output module 16 channel User guide MU110-16R(K)_2016.12_0220_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Germany

More information