Size: px
Start display at page:

Download ""

Transcription

1

2

3

4 10 min

5

6

7

8

9

10

11

12

13

14

15 A B C D

16 TN-C TN-C-S IT Transformer L1 L2 L3 PEN Transformer L1 L2 L3 N PE Transformer PE L1 L2 L3 PE SG36KTL-M PE SG36KTL-M SG36KTL-M

17

18

19

20 P/Pn Ambient temperature ( )

21 P max. Working area 0 Vmin 400 Vgrid [V] Vmax

22 Start 1 Unpacking and Inspection 2 Read User Manual Install Immediately? No 3 Storage 4 Yes Mounting Location Selection 5 Moving Inverter 6 Mounting the Inverter 7 Electrical Connection 8 9 Check before Commissioning Commissioning 10 Troubleshooting Success? No Yes End

23

24 395mm 680mm 915mm

25 光伏并网逆变器 GRID-CONNECTED PV INVERTER 1 型号 Model 序列号 S/N 直流输入 DC-Input SG36KTL-M 最大输入电压 Max. Inptut Voltage 最小 MPP 电压 Min. MPP Voltage 最大 MPP 电压 Max. MPP Voltage 最大输入电流 Max. Input Current 最大短路电流 Isc PV 交流输出 AC-Output 额定输出电压 Rated Output Voltage 额定输出频率 Rated Output Frequency 最大输出电流 Max. Output Current 额定输出功率 Rated Output Power 最大视在功率 Max. Apparent Power 功率因数范围 Power Factor Range 安全等级 Safety Class 过压等级 Overvoltage Category 防护等级 Enclosure 工作温度范围 Ambient Temperature DC 1100V DC 200V DC 1000V DC 88A DC 96A 3/PE or 3/N/PE, AC 230/400V 50Hz/60Hz AC 53.5A 36KW 36KVA 0.8Leading...0.8Lagging Ⅰ II[AC], II[DC] IP 阳光电源股份有限公司 SUNGROW POWER SUPPLY CO., LTD. 中国制造 Made in China 4

26 A B C D E F G

27 (

28 Flammable wall

29 >300mm ground Leaning forward Up side down Leaning backward Ground >450mm Frame Installation finished

30 Max. ambient temperature: +60 C Min. ambient temperature: -25 C Max. relative humidity: +100% Cool air Hot air 600mm 800mm 450mm Ground Cool air Hot air 600mm 800mm 800mm 600mm

31 X x10

32 M10 45

33 Install backplate E F C B A D Hang inverter 2 1 2

34 Mark positions Drill holes

35 Install backplate Hang inverter 2 1 2

36

37 2 3 4 N L1 L2 L Front view Bottom view

38 L1 L2 L3 PE Inverter 1 Inverter 2 Inverter n

39 U2 V2 W2 Low-voltage Side High-voltage Side U1 V1 W1 MV Transformer Inverter 1 Inverter 2 Inverter n

40

41 L1 L2 L3 M1 M2 M3 M Max. allowable grid impedance [Ohm] AC voltage without load[v] 500

42 A C B D PE L1 L2 L3 N

43 L1 L2 L3 PE N L1 L2 L3 PE N

44

45 PV Input 1 MPPT1 PV Input 2 MPPT2 Inverter Inside PV Input 3 MPPT3 β

46 7mm

47 Positive Crimp Contact Negative Crimp Contact Positive Insulator Cable Gland Crimp Contact Negative Insulator Cable Gland Crimp Contact OFF ON

48 DC DC - - +

49 Inverter 1 Inverter 2 Inverter n PV Arrays 1 PV Arrays 2 PE PE PE PV Arrays n Mounting Frame of PV arrays Equipotential cable Grounding of PV Power System Inverter AC Circuit Breaker L1L2 L3 L1 L2 L3 PE AC Grounding Electrode Grounding of Inverter AC Side

50 M6

51 Ω 120Ω terminating resistor switch ONOFF Configuration circuitboard RS485 bus terminal

52 Inverter RS485-2 RS485 cable Ethernet cable RS485 terminal Data Logger Ethernet terminal PC Ethernet port RS485 Communication of inverter 120ohm Ω.

53 Inverter 1 RS485-2 Inverter 2 RS485-2 Inverter n RS485-2 RS485 cable Ethernet cable 120Ω Shielding layer is grounded RS485 terminal Data Logger Ethernet terminal PC Ethernet port 120Ω Multiple inverters in daisy chain n>15 120ohm 120ohm 120ohm A B GND 120ohm 120ohm A B GND

54

55

56 Countries GB DE FR IT ES AT AU CZ BE DK GR NL PT CN SE RO TH TK US KR IND ZAF CHL BRA TPE other Warning! Only qualified personnel rare allowed to adjust following parameters. Improper settings may cause damage to the inverter! GR Grid codes GR_L GR_IS

57 DE Grid codes LV MV TK Grid codes AG YG TH Grid codes 220V 230V ZAF Gird sodes RPPs NRS Other Grid codes 50Hz 60Hz

58 Pro-Stage Single-stage Multi-stage Time YY/MM/DD Date: 15/01/31 Time: 10:30:55 Modbus param Addr 001 Setting confirmation Countries Other Pro-stage Single-stage Grid codes 50Hz Date 2015/01/31 Confirm above settings? 001 P(%) t P-ac E-day E-tot State kw kw 15.6 kwh h kwh kw Run h 100.0% 2015/01/31 10:30

59

60

61

62

63

64

65

66

67 1 2 2

68

69

70

71 001 P(%) t % P-ac E-day E-tot State kwh kw kw kwh kw Run 2015/01/31 10:30 ESC ENTER Menu 50% Run-inform His-inform Start/Stop Set-param ENTER ENTER His-inform Start/Stop Set-param Flt-record Evt-record ENTER Run-record Energy-record Start Stop Sys-param Run-param Pro-param Com-param Advanced Settings ENTER ENTER ENTER ENTER Sys-param Languages Time Energy-adj Load default Firmware version Run-param P-Q param Time param LVRT param HVRT param Derating param Iso param Countries GB DE FR IT ES AT AU CZ BE DK GR NL PT CN SE RO US KR TH TK IND ZAF CHL BRA TPE other Com-param Addr 001 h h

72 Device address Power curve Icon &active power limit 001 P(%) t % P-ac kw kw E-day h 15.6 kwh E-tot State kwh kw Run h 2015/01/31 10:30 Present power Today s energy Total energy Inverter state Time

73 Current fault P1/1 1 GRID %

74 DC power input 00000W Vdc[V] Idc[A] Pdc[W] DC DC DC DC1-1: 4.23A DC2-3: 4.23A DC1-2: 4.23A DC3-1: 4.23A DC1-3: 4.23A DC3-2: 4.23A DC2-1: 4.23A DC2-2: 4.23A R S T Vac[V] Iac[A] Pac[W] F[Hz] CO2-reduce E-month h-total T-today Temp ISO 6kg 10kWh 1h 63min 25.0 C 20000kΩ P-W S-Va Country Grid code 100W 130VA Other 60Hz

75 Fl t - r ecor d P 1/ / 01/ 31 10: 16: 10 [ 0008] / 01/ 31 10: 16: 10 [ 0008] / 01/ 31 10: 16: 10 [ 0008] / 01/ 31 10: 16: 10 [ 0008] / 01/ 31 10: 16: 10 [ 0040] Evt-record P 1/ /01/31 10:16:10 Fault His-inform Flt-record Evt-record Run-record Run- r ecor d P1/ / 01/ 21( 30) Run- r ecor d T4 2015/ 01/ 21 P001/ / 01/ 21 18: 50 Energy-record

76 DC power input Vdc[V] DC W Idc[A] Pdc[W] DC1-1: 4.23A DC2-3: 4.23A DC1-2: 4.23A DC3-1: 4.23A DC2 DC DC1-3: 4.23A DC3-2: 4.23A DC2-1: 4.23A DC3-3: 4.23A DC2-2: 4.23A R S T Vac[V] P-W S-Va 100W 130VA CO2-reduce E-month 6kg 10kWh Iac[A] Pac[W] Country Other h-total 1h F[Hz] Grid code 60Hz T-today 63min Temp 25.0 C ISO 20000kΩ Energy-record Power curve Daily energy histogram Monthly energy histogram Annual energy histogram P(%) 110 Power curve 2015/01/31 P1/ t 5 Max:33.0kW E(kWh) Dai l y ener gy hi st ogr am 2015/01 P1/ :599kWh 31 t

77 Mont hl y ener gy hi st ogr am E(kWh) P1/ Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov now 10:19000kWh t E(KWh) Annual energy histogram P1/ :190000kWh t Start/Stop Start Confirm start inverter? Stop Confirm stop inverter?

78 Set-param Password: Set-param Sys-param Run-param Pro-param Com-param Advanced Settings Sys-param Languages Time Energy-adj Load default Firmware version Languages Auto English Deutsch Francaise Italia 中文

79 Time YY/MM/DD Date: 15/01/31 Time: 10:30:55 Energy-adj +0000kWh

80 Load default Confirm resume setting? Firmware version Device Type: SG36KTL-M SN: A Ver: DSP_SG36KTL-M_V11_V1_A_M LCD_SG36KTL-M_V03_A_M

81 Run-param P-Q param Time param LVRT param HVRT param Derating param Iso param

82

83 P-Q Param P-W limits 110.0% Rate limit [ON/OFF] Power raise 100%/min Power decline 6000%/min Fault slowup [ON/OFF] Slowup rate 10%/min P-Q param Q-Var switch [OFF] RF Q-Var limits %

84 Run- par am- Q( P) Upper PF Cap Lower Power % Lower PF I nd Upper Power % COS Ф Upper PF Cap P1 General Q(P) curve COS Ф Default Q(P) curve Capacitive P/Pn 1 Lower Power Power Upper Power Upper PF Cap =1 Lower Power =50% P1 Power Upper Power =100% P/Pn L2 Inductive Lower PF Ind P2 Lower PF Ind =0.9 P2

85 Run-param-Q(U) Lower Q/Sn Ind 050.0% Upper Q/Sn Cap 050.0% Lower U Limit 095.0% Upper U Limit 115.0% Run-param-Q(U) U1 Limit 095.0% U2 Limit 105.0% Hysteresis 3.0%

86 Q/Sn Upper Q/Sn Ind P1 Hysteresis Lower U limit P2 U1 Limit U2 Limit P3 Upper U limit Grid voltage Hysteresis Lower Q/Sn Cap P4 Run-param-Q(P) P3/3 PA 020.0% PB 050.0% PC 100.0% Pf max Uin 105.0% Uout 100.0%

87 > Inductive Default Curve Deviation Capacitive No Regulation cos = ± 0,98 Depends on the capacity of the inverter. Run- par am- Q( U) P3/ 4 V2i % V1i % V1s % V2s % Qmax % Pi n % Run- par am- Q( U) P4/ 4 Pout % Cur ve [ A]

88 A B Inductive A B Inductive - - Capacitive C Capacitive C D D A: Default B P-Q param Save P-W setting [ON/OFF] Save Q-Var setting [ON/OFF]

89 Time-param Standby time Recovery time 020s 000s LVRT param LVRT [ON/OFF] LVRT kf 02 LVRT normal volt 000.0V LVRT T S LVRT tolera volt 00.0V LVRT T2 0.00S HVRT param HVRT [ON/OFF] HVRT kf 010 HVRT normal volt 110.0% HVRT T S HVRT tolera volt 130.0% HVRT T S

90 Derating param Fre-Derating F1 [ON/OFF] 50.00Hz P1 100% F Hz P2 100% F Hz P3 100% ISO param ISO [ON/OFF] ISO pro value 30kΩ

91 Countries GB DE FR IT ES AT AU CZ BE DK GR NL PT CN SE RO TH TK US KR IND ZAF CHL BRA TPE other

92 GR Grid codes DE Grid codes TK Grid codes GR_L GR_IS LV MV AG YG TH Grid codes ZAF Gird sodes Other Grid codes 220V 230V RPPs NRS 50Hz 60Hz Pro-Stage Single-stage Multi-stage Pro-param Single Vgrid-max 000.0V Vgrid-min 000.0V Fgrid-max 00.00Hz Fgrid-min 00.00Hz

93 Pro-param Multi Pro-param Multi I-Max-V.grid 000.0V I-Min-V.grid 000.0V I-Max-V.time s II-Max-V.grid 000.0V II-Max-V.time s I-Min-V.time s II-Min-V.grid 000.0V II-Min-V.time s Pro-param Multi Pro-param Multi I-Min-F.grid 00.00Hz I-Max-F.grid 00.00Hz I-Min-F.time s I-Max-F.time s II-Min-F.grid 00.00Hz II-Max-F.grid 00.00Hz II-Min-F.time s II-Max-F.time s Ⅰ Ⅰ Ⅱ Ⅱ Ⅰ Ⅰ Ⅱ Ⅱ Ⅰ Ⅰ Ⅱ Ⅱ Ⅰ Ⅰ Ⅱ Ⅱ Ⅰ Ⅰ Ⅱ Ⅱ Ⅰ Ⅰ Ⅱ Ⅱ Ⅰ Ⅰ Ⅱ Ⅱ Ⅰ Ⅰ Ⅱ Ⅱ

94 Pro-recover Vmax-recover 000.0V Vmin-recover 000.0V Fmax-recover 00.00Hz Fmin-recover 00.00Hz Setting confirmation Countries Pro-stage Grid codes Other Single-stage MV Date 2015/01/31 Confirm above settings? Com-param Modbus param Uart param

95 Modbus param Addr 001 Uart param Baud [9600] Parity [ NO ] Stop bit [1] Advanced set t i ngs Passwor d:

96 Advanced settings PVS Detect 10min Grid Max-v Unbalance PVS Detect ON OFF Reset Set-param Advanced set t i ngs Passwor d: Advanced settings PVS Detect 10min Grid Max-v Unbalance

97 10mi n Max- V 10mi n Max- V Pr o- val ue Rec- val ue [ OFF] V V Grid Unbalance Grid Unbalance Amplitude Pro-time [OFF] 10% 05.00S

98

99

100

101

102

103 Sungrow Power Supply Co., Ltd. Add: No.1699 Xiyou Rd.,New & High Technology Industrial Development Zone, ,Hefei, P. R. China. Post Zip: Web: Tel: / Fax: Specifications are subject to changes without advance notice.

WARNING. Disconnect the inverter from all the external power sources before service!

WARNING. Disconnect the inverter from all the external power sources before service! WARNING Disconnect the inverter from all the external power sources before service! Do not touch live parts until 10 minutes after disconnection 10 min from the sources! Hot surface! May exceed 60! Danger

More information

WARNING. Disconnect the inverter from all the external power sources before service!

WARNING. Disconnect the inverter from all the external power sources before service! WARNING Disconnect the inverter from all the external power sources before service! Do not touch live parts until 10 minutes after disconnection 10 min from the sources! Hot surface! May exceed 60! Danger

More information

WARNING. Disconnect the inverter from all the external power sources before service!

WARNING. Disconnect the inverter from all the external power sources before service! WARNING Disconnect the inverter from all the external power sources before service! Do not touch live parts until 10 minutes after disconnection 10 min from the sources! Hot surface! May exceed 60! Danger

More information

Conext CL-60 Inverter Active and Reactive Power Control and LVRT

Conext CL-60 Inverter Active and Reactive Power Control and LVRT Conext CL-60 Inverter Active and Reactive Power Control and LVRT http://solar.schneider-electric.com 976-0381-01-01/B March 2017 Application Note EXCLUSION FOR DOCUMENTATION UNLESS SPECIFICALLY AGREED

More information

3-Channel Constant Current LED Driver UCS1903

3-Channel Constant Current LED Driver UCS1903 3-Channel Constant Current LED Driver UCS1903 (Products descriptions) The product UCS1903 is the three-channel LED drive control circuit, internal integration MCU digital interface, data latches, LED high

More information

Conext CL125 Inverter - Active and Reactive Power Control and LVRT/HVRT

Conext CL125 Inverter - Active and Reactive Power Control and LVRT/HVRT Conext CL125 Inverter - Active and Reactive Power Control and LVRT/HVRT http://solar.schneider-electric.com 976-0406-01-01/A May 2018 Application Note EXCLUSION FOR DOCUMENTATION UNLESS SPECIFICALLY AGREED

More information

/ The allrounder with maximum yield. / Smart Grid Ready. / WLAN interface

/ The allrounder with maximum yield. / Smart Grid Ready. / WLAN interface / Battery Charging Systems / Welding Technology / Solar Electronics FRONIUS IG PLUS / The allrounder with maximum yield. / Fronius MIX technology / HF transformer switchover / PC board replacement process

More information

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W Page 2 / 16 INDEX: GENERAL TYPES ACESSORIES AND OPTIONS INSTALLATION WIRING DIAGRAMS CONNECTING TERMINALS DIAGRAMS WIRING DIAGRAM DESCRIPTION WORKING DESCRIPTION AND KEYBOARD WORKING DESCRIPTION AND PROGRAMMING

More information

Technical Information SMA SOLID-Q 50 / PRO 60 Modbus Interface

Technical Information SMA SOLID-Q 50 / PRO 60 Modbus Interface Technical Information SMA SOLID-Q 50 / PRO 60 Modbus Interface SMASOLID-Q-Modbus-TI-en-10 Version 1.0 ENGLISH Legal Provisions The information contained in these documents is property of SMA New Energy

More information

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

ENA33LCD. Power line analyzer. User and service manual.   Obrezija 5 SI-1411 Izlake ENA33LCD Power line analyzer User and service manual version 2.9 (FW version 6.8 and newer) ETI, d.o.o. Obrezija 5 SI-1411 Izlake www.etigroup.eu/products-services 1. Front control panel and terminal plate

More information

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS INSTRUCTION MANUAL BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS 1/23 More information than that reported

More information

Power Quality and Energy Measurement PEM533

Power Quality and Energy Measurement PEM533 Power Quality and Energy Measurement _D00013_02_D_XXEN/11.2014 Power Quality and Energy Measurement 0.5 S Product description The digital universal measuring device is suited for measuring and displaying

More information

Power Quality and Energy Measurement PEM735

Power Quality and Energy Measurement PEM735 Power Quality and Energy Measurement PEM75 PEM75_D00084_01_D_XXEN/01.2015 Power Quality and Energy Measurement PEM75 class A Product description The digital universal measuring device PEM75 is suited for

More information

TECHNICAL DATA FRONIUS SYMO ( M, M, M, M, M)

TECHNICAL DATA FRONIUS SYMO ( M, M, M, M, M) TECHNICAL DATA FRONIUS SYMO (10.0-3-M, 12.5-3-M, 15.0-3-M, 17.5-3-M, 20.0-3-M) INPUT DATA SYMO 10.0-3-M SYMO 12.5-3-M SYMO 15.0-3-M SYMO 17.5-3-M SYMO 20.0-3-M Max. input current (I dc max 1 / I dc max

More information

/ PC board replacement. / Smart Grid Ready TECHNICAL DATA FRONIUS SYMO (3.0-3-S, S, S, M, M, M)

/ PC board replacement. / Smart Grid Ready TECHNICAL DATA FRONIUS SYMO (3.0-3-S, S, S, M, M, M) solarpowerpanels.net.au Brisbane - Gold Coast - Sunshine Coast 0431 094 756 / Perfect Welding / Solar Energy / Perfect Charging FRONIUS SYMO / Smarter, Lighter, More Flexible N 100 W E 0 S / SnapINverter

More information

Power Quality and Energy Measurement PEM575

Power Quality and Energy Measurement PEM575 Power Quality and Energy Measurement _D00016_03_D_XXEN/12.2015 Power Quality and Energy Measurement Product description The digital universal measuring device is suited for measuring and displaying electrical

More information

ZHUHAI PILOT TECHNOLOGY CO., LTD.

ZHUHAI PILOT TECHNOLOGY CO., LTD. SPM32 Multifunctional Power Meter SPM32 Multifunction Power Meter Installation & Operation Manual V1.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. Danger and warning! This device can be installed only by professionals.

More information

3-phase meter with direct connection and pulse or Modbus RS485 output

3-phase meter with direct connection and pulse or Modbus RS485 output 87045 LIMOGES Cedex Telephone: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 3-phase meter with direct connection and CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...

More information

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INSTRUCTIONS MANUAL IM831-U v0.92 HRI-R40W sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INDEX: GENERAL TYPES ACESSORIES AND OPTIONS

More information

APPROVAL SHEET I TUNER 12V/10.83A EA11703A(01) EA11703A-120 APP D EDAC POWER ELECTRONICS CO., LTD. TEL: FAX:

APPROVAL SHEET I TUNER 12V/10.83A EA11703A(01) EA11703A-120 APP D EDAC POWER ELECTRONICS CO., LTD. TEL: FAX: APPROVAL SHEET CUSTOMER I TUNER CUSTOMER P/N DESCRIPTION EDAC MPN EDAC MODEL NO FOR SAFETY 12V/10.83A EA11703A(01) EA11703A-120 DATE 2016-02-25 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED

More information

/ The allrounder with maximum yield. Technical data: Fronius IG Plus (25 V-1, 30 V-1, 35 V-1, 50 V-1, 55 V-1, 60 V-1)

/ The allrounder with maximum yield. Technical data: Fronius IG Plus (25 V-1, 30 V-1, 35 V-1, 50 V-1, 55 V-1, 60 V-1) / Battery Charging Systems / Welding Technology / Solar Electronics FRONIUS IG PLUS / The allrounder with maximum yield. / Fronius MIX concept / HF transformer switchover / PC board replacement concept

More information

03 / Data Sheet. PIKO-Inverter

03 / Data Sheet. PIKO-Inverter 03 / 2013 EN Data Sheet PIKO-Inverter 3.0 3.6 4.2 5.5 7.0 8.3 10.1 Table of content 4 Overview technical data Inverter single-phase 5 Inverter PIKO 3.0 5 Inverter PIKO 3.6 Inverter three-phase 6 Inverter

More information

Power Quality and Energy Measurement PEM575

Power Quality and Energy Measurement PEM575 Power Quality and Energy Measurement _D00016_00_D_XXEN/06.2013 Power Quality and Energy Measurement Product description The digital universal measuring device is suited for measuring and displaying electrical

More information

PLA 33. Power line analyzer. User and service manual. version 2.4

PLA 33. Power line analyzer. User and service manual. version 2.4 PLA 33 Power line analyzer User and service manual version 2.4 Content. Front control panel and terminal plate...3 7.2.2. System frequency setting...0 2. Device description...4 7.2.3. Password protection...0

More information

Single phase meter with direct connection and pulse or Modbus RS485 output

Single phase meter with direct connection and pulse or Modbus RS485 output 87045 LIMOGES Cedex Telephone: +33(0)5 55 06 87 87 Fax: +33(0)5 55 06 88 88 Single phase meter with direct connection CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...

More information

Operation and Installation manual

Operation and Installation manual Operation and Installation manual SOLIVIA 15 EU G4 TL and SOLIVIA 20 EU G4 TL EU ENGLISH This manual is subject to change. Please check our website at www.solar-inverter.com for the most up-to-date manual

More information

Conext CL-60 PV Inverter

Conext CL-60 PV Inverter Conext CL-60 PV Inverter Owner s Guide 975-0768-01-01 Rev G 12-2017 CL-60E CL-60JP CL-60A http://solar.schneider-electric.com Conext CL-60 PV Inverter Owner s Guide http://solar.schneider-electric.com

More information

200Watts Single Output LED Display Power Supply

200Watts Single Output LED Display Power Supply VT-UP200 Series Features: Universal C input (90~264Vac) With ctive PFC, PF>0.95 Surge 300Vac for 60S High Efficiency, long life and High reliability Output protections: OLP/OVP/SCP/OPP 1+1 parallel function,

More information

Data Sheet. Customer: Metal Film Precision MELF Resistor-CSRV Series Size: 0102/0204/0207

Data Sheet. Customer: Metal Film Precision MELF Resistor-CSRV Series Size: 0102/0204/0207 Data Sheet Customer: Product: -CSRV Series Size: 02/0204/0207 Issued Date: Edition: 04-Aug-17 REV.B VIKING TECH CORPORATION 光頡科技股份有限公司 No.70 Guangfu N. Rd., Hukou Township, Hsinchu County 303, Taiwan TEL:886-3-5972931

More information

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready / Battery Charging Systems / Welding Technology / Solar Electronics FRONIUS SYMO / Maximum flexibility for the applications of tomorrow. / PC board replacement process / Mounting system / WLAN interface

More information

Metal Film Precision Resistor. Features

Metal Film Precision Resistor. Features Features -Excellent overall stability -Tight tolerance down to ±0.1% -Extremely low TCR down to ±10 PPM/ C -High power rating up to 1 Watts Construction & Dimension 6 5 1 2 3 4 Applications -Telecommunication

More information

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet PowerLogic power-monitoring units PM700 series power meter Technical data sheet 2009 Functions and characteristics The PowerLogic PM700 series power meter offers all the measurement capabilities required

More information

DEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description

DEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description Description of options Option H3 Serial communication Profibus DP Multi-line 2 version 2 4189340279I SW 2.42.X Description of option Functional description DEIF A/S Parameter table Data tables DEIF A/S,

More information

DPF-MAC Auto power factor controller

DPF-MAC Auto power factor controller Digital Electric& Electronics System DPF-MAC Auto power factor controller MULTI POWER FACTOR AUTOMATIC MULTI POWER FACTOR AUTOMATIC Introduction DPF-MAC increases usage efficiency by controlling the power

More information

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA

More information

ISOMETER IRDH575. Approvals

ISOMETER IRDH575. Approvals Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation

More information

Power Quality and Energy Measurement PEM330/PEM333

Power Quality and Energy Measurement PEM330/PEM333 Power Quality and Energy Measurement PEM330/PEM333 TDB310001en / 02.2013 Power Quality and Energy Measurement PEM330/PEM333 0.5S Product description The universal measuring device PEM330/333 is used to

More information

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 0640 807-0 Fax: 0640 807-259 IT system floor-standing distribution cabinet Series -IPS-F/EDS for supplying power to medical locations

More information

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Installation and Operating Instructions. Power IT Power Factor Controller RVC Installation and Operating Instructions Power IT Power Factor Controller RVC Table of contents Page 1. Read this first... 3 About this Instruction Manual... 3 Safety... 3 Electromagnetic compatibility...

More information

8730 Electric Parameter Meter User manual

8730 Electric Parameter Meter User manual 8730 Electric Parameter Meter User manual ( Ver 2.10 ) Qingdao QINGZHI Instruments Co., Ltd. Address: 5th Floor, Building 1, Shenghe Building, No.58 Shandongtou Road, Laoshan District, Qingdao, China,

More information

SUPPLY NETWORK ANALYZER CVM-96 SERIES

SUPPLY NETWORK ANALYZER CVM-96 SERIES SUPPLY NETWORK ANALYZER CVM-96 SERIES (Power Demand) INSTRUCTION MANUAL ( M 981 326 / 00B - GB) (c) CIRCUTOR S.A. ----- Supply network analyzer CVM-96 ------ User's manual --- Page No. 1 CVM-96 SUPPLY

More information

Monitoring Electric Network Via Internet

Monitoring Electric Network Via Internet Monitoring Electric Network Via Internet NETWORK ANALYSER let "it" analyse! MPR63 Real time monitoring via internet / intranet Measurement of all electrical parameters Including Harmonics Automatic recording

More information

COUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet

COUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet INSTRUCTION MANUAL COUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet EN countis e27 countis e28 - mid www.socomec.com/ en/countis-e2x EN Contents 1. Documentation.... 3 2. Hazards and warnings...

More information

Data Sheet. Customer: Pulse Withstanding Chip Resistor - PWR Series(High Power) Size: 0603/0805/1206/1210 Issued Date: 18-Feb-17

Data Sheet. Customer: Pulse Withstanding Chip Resistor - PWR Series(High Power) Size: 0603/0805/1206/1210 Issued Date: 18-Feb-17 Data Sheet Customer: Product: - PWR Series(High Power) Size: ///12 Issued Date: 18-Feb-17 Edition: Draft VIKING TECH CORPORATION 光頡科技股份有限公司 No.70 Guangfu N. Rd., Hukou Township, Hsinchu County 303, Taiwan

More information

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202 DMTME-96 2CSG133030R4022 M204675 DMTME-I-485-96 2CSG163030R4022 M204685 2CSG445001D0202 GB Operation and assembly instructions DMTME-96: three-phase multimeter for panel mounting, used also in singlephase

More information

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the

More information

Customer s Approval Signature

Customer s Approval Signature Adapter Technology Co., Ltd. Specification for Approval Customer : ELFA AB Part Name : AC ADAPTER Description : 12 Volts / 12.5 Amps Model No. : STD-12125 (LEVEL V) Customer P / N : 69-234-84 Product P

More information

DIRIS Ap RS485 JBUS/MODBUS COM. Systèmes de Coupure et de Protection Industrial Switching and Protection Systems ON 1

DIRIS Ap RS485 JBUS/MODBUS COM. Systèmes de Coupure et de Protection Industrial Switching and Protection Systems ON 1 DIRIS Ap RS485 JBUS/MODBUS F GB ON 1 D COM I NL E P Systèmes de Coupure et de Protection Industrial Switching and Protection Systems PRELIMINARY OPERATIONS NB: For personnel and product safety please read

More information

SUPPLY NETWORK ANALYZER

SUPPLY NETWORK ANALYZER SUPPLY NETWORK ANALYZER CVM-144 SERIES (Ethernet) (Ver 6.11 and higher) INSTRUCTION MANUAL (M98203401-03-06A) CIRCUTOR S.A. ----- Supply network analyzer CVM-144 ------ User's manual --- Page No. 1 CONTENTS

More information

ABB solar inverters. User s manual PVS-JB-8-M junction box with monitoring for PVS800 central inverters

ABB solar inverters. User s manual PVS-JB-8-M junction box with monitoring for PVS800 central inverters ABB solar inverters User s manual PVS-JB-8-M junction box with monitoring for PVS800 central inverters List of related manuals Inverter hardware manuals and guides PVS800-57 central inverters (100 to 500

More information

Installation Instructions and Reference Handbook. Installation instructions

Installation Instructions and Reference Handbook. Installation instructions Installation Instructions and Reference Handbook Multi-instrument MIB 7000/7000C/7020 4189320016B (UK) DEIF A/S Product information Installation instructions Basic operation DEIF A/S, Frisenborgvej 33

More information

LOW POWER PLA SERIES. PLA Series Brief Profile. Interfaces. Electronic DC Loads

LOW POWER PLA SERIES. PLA Series Brief Profile. Interfaces. Electronic DC Loads Electronic DC Loads LOW POWER PLA SERIES PLA Series Brief Profile The electronic loads of PLA series combine the classic design of large, easy-to-read displays with modern interfaces and a wide range of

More information

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready / Perfect Welding / Solar Energy / Perfect Charging Fronius Symo / Maximum flexibility for the applications of tomorrow. N 1 W E S / SnapINverter technology / Integrated data communication / SuperFlex

More information

PEM353. Universal measuring device

PEM353. Universal measuring device 353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities

More information

Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems

Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Tyco Electronics UK Limited Crompton Instruments Freebournes Road, Witham, Essex, CM8 3AH, UK Tel: +44 1376 509 509

More information

PM-PA/PM-PAC POWER ANALYZER

PM-PA/PM-PAC POWER ANALYZER PM-PA/PM-PAC POWER ANALYZER 1. INTRODUCTION Power Analyzer is an ideal device to control measure and monitor all electrical parameters of a system. Thanks to its four display rows, all parameters can be

More information

Data Sheet. Customer: Product: Automotive Grade Thick Film Array Chip Resistor CN..A Series 0402x4 / 0603x4 / 0201x2(Flat) / 0201x4(Flat)

Data Sheet. Customer: Product: Automotive Grade Thick Film Array Chip Resistor CN..A Series 0402x4 / 0603x4 / 0201x2(Flat) / 0201x4(Flat) Data Sheet Customer: Product: CN.. Series Size: Issued Date: Edition: 0402x4 / 0603x4 / 0201x2(Flat) / 0201x4(Flat) 15-Jul-16 REV.4 VIKING TECH CORPORTION 光頡科技股份有限公司 No.70 Guangfu N. Rd., Hukou Township,

More information

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready / Battery Charging Systems / Welding Technology / Solar Electronics Fronius Symo / Maximum flexibility for the applications of tomorrow. / PC board replacement process / Mounting system / WLAN interface

More information

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current

More information

IMS20 Series Driver 2 Phase Stepping Driver Units 二相步进马达

IMS20 Series Driver 2 Phase Stepping Driver Units 二相步进马达 IMS20 Series Driver 2 Phase Stepping Driver Units 二相步进马达 compact package matching most existing motors 100~120Vac Single Phase Power Input Opto-isolated inputs and outputs uto-current down feature Half

More information

MULTIFUNCTION GRAPHICAL UNIT MGU 800

MULTIFUNCTION GRAPHICAL UNIT MGU 800 MULTIFUNCTION GRAPHICAL UNIT MGU 800 For display, recording and evaluation of process instruments signals (level, temperature, pressure, etc.) 3.5" TFT display, multi-language menu Variety of possible

More information

Emotron FDU 2.0 Variable Speed Drive

Emotron FDU 2.0 Variable Speed Drive Emotron FDU 2.0 Variable Speed Drive Data Sheet English Emotron FDU 2.0 Variable Speed Drive Electrical specifications related to model Table 1 Typical motor power at mains voltage 400 V Model Max. output

More information

VIP Current & Power Multimeter

VIP Current & Power Multimeter VIP Current & Power Multimeter Rev 1.6 Table of Contents 1. Mechanical Installation... 3 2. Wiring diagram... 4 3. Specifications... 5 Technical Specifications... 5 3.2 Measuring Specifications... 5 4.

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

TECHNICAL DATA FRONIUS SYMO (3.0-3-S, S, S, M, M, M)

TECHNICAL DATA FRONIUS SYMO (3.0-3-S, S, S, M, M, M) / Perfect Welding / Solar Energy / Perfect Charging FRONIUS Symo Maximum flexibility for the applications of tomorrow N 1 W E S SnapINverter technology Integrated data communication Dynamic Peak Manager

More information

Programmable AC Voltage Transducer MT416

Programmable AC Voltage Transducer MT416 Programmable AC Voltage Transducer MT416 RMS AC voltage or frequency measurements Voltage auto measurements up to 600 V L-N Frequency measurement 16 400 Hz AC or universal wide auiliary power 24 300 Vdc,

More information

FRONIUS IG PLUS TRANSFORMER INVERTER

FRONIUS IG PLUS TRANSFORMER INVERTER / Battery Charging Systems / Welding Technology / Solar Electronics FRONIUS IG PLUS TRANSFORMER INVERTER / The allrounder with maximum yield. / Fronius MIX concept / HF transformer switchover / Fronius

More information

COUNTIS E23. Three-phase energy meter Direct - 80 A MODBUS. Instruction manual. en/countis-e2x

COUNTIS E23. Three-phase energy meter Direct - 80 A MODBUS. Instruction manual.   en/countis-e2x Instruction manual COUNTIS E23/E24 Three-phase energy meter Direct - 80 A MODBUS COUNTIS E23 COUNTIS E24 - MID www.socomec.com/ en/countis-e2x Contents 1. Documentation.... 3 2. Hazards and warnings...

More information

MultiMeter-Pocket CAT III 1000 V

MultiMeter-Pocket CAT III 1000 V 02 10 18 26 34 42 50 58 66 74 82 DE GB NL DK FR ES IT PL FI PT SE AC DC AC DC CAT III 1000 V 90 98 106 114 122 130 138 146 154 162 170 NO TR RU UA CZ EE LV LT RO BG GR ! Read the operating instructions

More information

Operating Instructions

Operating Instructions 4XH35QB151210 Small General Frequency Converter Operating Instructions 220V 0.75KW 5.5KW 400V 0.75KW 15KW Please read the instruction carefully and understand the contents so that it can be installed and

More information

General Specifications

General Specifications General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with

More information

Fault 514: communication error between the meter and the SH5K+

Fault 514: communication error between the meter and the SH5K+ Fault 514: communication error between the meter and the SH5K+ Fault 514 indicates that there is a communication error between the meter and the inverter. 1 Summary It is best to call us as soon as possible

More information

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter SDM630MCT-RJV-333mV SDM630MCT-RJA-00mA Three phase multifunction din rail energy meter Plug-in solution; labor saving; wiring mistake free Measures kwh KVarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc.

More information

MANUAL PCE-UT232

MANUAL PCE-UT232 www.pce-group-europe.com PCE- Deutschland Gmb H & Co. KG Tel: +49 029 03 976 99-0 Fax: +49 029 03 976 99-29 info@warensortiment.de www.warensortiment.de PCE Group Ibérica S.L. Tel: +34 967 543 548 Fax:

More information

Current Clamp. 210

Current Clamp. 210 Our range of devices includes clamp meters for measuring current leaks, AC and DC current, voltage, power, resistance, continuity, capacitance or frequency. Some clamp meters have a clearly arranged display

More information

Modbus communication module for TCX2: AEX-MOD

Modbus communication module for TCX2: AEX-MOD Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation

More information

Growatt 4000 UE / 5000 UE / 6000 UE

Growatt 4000 UE / 5000 UE / 6000 UE Growatt 4000 UE / 5000 UE / 6000 UE Leading - edge Technology 6k efficiency 98% DC input voltage up to 800V 97% Maximum efficiency of 97.9% 96% 95% Internal DC switch 94% Transformerless 93% 92% Compact

More information

Product Specification

Product Specification Product Specification Product Name: 120W micro infrared remote control LED driver LDP-120M170 Product Model: LDP-120R170 Rev. A.1 CE CE Address: Sangtai Industrial Park Guanwai Xiaobaimang Songbai Road

More information

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN Energy Management Energy Meter Type EM23 DIN Certified according to MID Directive (option PF only): see how to order below Other version available (not certified, option X): see how to order on the next

More information

Declaration of Conformity

Declaration of Conformity for SkyBox True Hybrid Energy System Purpose The intent of this document is to specify that the OutBack model listed below conforms to the following standards for grid-interactive inverter/chargers intended

More information

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready / Perfect Welding / Solar Energy / Perfect Charging Fronius Symo / Maximum flexibility for the applications of tomorrow. N W E S / SnapINverter technology / Integrated data communication / SuperFlex Design

More information

RM-2000-RTDW Remote Monitor User s Guide

RM-2000-RTDW Remote Monitor User s Guide RM-2000-RTDW Remote Monitor User s Guide The RM-2000-RTDW motor-monitoring device can be used to monitor and/or control SymCom s Model 777 via an RS-485 Modbus network. Two form C output relays are available

More information

Distributed by: www.jameco.com 1-8-831-4242 The content and copyrights of the attached material are the property of its owner. 35mW SURFACE MOUNT ENER DIODE Features Planar Die Construction 35mW Power

More information

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY

More information

7051Plus / 5051Plus. Extended Specification

7051Plus / 5051Plus. Extended Specification 7051Plus / 5051Plus Extended Specification V1.1 Time Electronics, Botany Industrial Estate,Tonbridge, Kent, TN9 1RH England Tel: 44 (0)1732 355993 Fax: 44 (0) 1732 770312. E-mail: mail@timeelectronics.co.uk

More information

Metasys Integrator Power Measurement Ltd. Application

Metasys Integrator Power Measurement Ltd. Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date January 19, 2006 APPLICATION NOTE Metasys Integrator Power Measurement Ltd. Application lntroduction Page

More information

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering METERSUK LTD s a l e s @ m e t e r s. c o. u k 0 1 5 2 4 5 5 5 9 2 9 Series Smart Energy Meter KEY FEATURES Single Phase Metering Single phase metering 4 din modules, Standard DIN rail Format (DIN43880)

More information

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems T M 1 isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE1012110 / 12.2011 isolr275 / AGH-LR Ground Fault Monitor

More information

Universal-Transducer Multi-E11-MU

Universal-Transducer Multi-E11-MU Universal-Transducer Multi-E11-MU Safety Informations Observe instructions! The device described in these instructions shall only be installed by a qualified electrician according to both EN 50110-1/-2

More information

CVM-C5-ITF-485 CVM-C5-MC-485

CVM-C5-ITF-485 CVM-C5-MC-485 Power analyzer CVM-C5-ITF-485 CVM-C5-MC-485 CVM-C5-mV-485 INSTRUCTION MANUAL (M026B01-03-18A) 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below DANGER Warns

More information

APPENDIX APPENDIX A 1

APPENDIX APPENDIX A 1 A 1 SPECIFICATIONS Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 7VA 4VA/2.5W Sensor input Thermocouple

More information

Emotron FDU 2.0 Variable Speed Drive

Emotron FDU 2.0 Variable Speed Drive Data Sheet Emotron FDU 2.0 Variable Speed Drive Electrical specifications related to model Table 1 Typical motor power at mains voltage 400 V Model Max. output current for 60 s [Arms] Normal duty (120%)

More information

Energy Management Energy Analyzer Type EM112

Energy Management Energy Analyzer Type EM112 Energy Management Energy Analyzer Type EM112 Single phase energy analyzer Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Accuracy ±0.5% RDG (current/voltage Direct current measurement

More information

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready

/ Maximum flexibility for the applications of tomorrow. / Dynamic Peak Manager. / Smart Grid Ready / Perfect Welding / Solar Energy / Perfect Charging Fronius Symo / Maximum flexibility for the applications of tomorrow. N 1 W E S / SnapINverter technology / Integrated data communication / SuperFlex

More information

The future-proof inverter for small self-consumption systems

The future-proof inverter for small self-consumption systems FRONIUS Galvo The future-proof inverter for small self-consumption systems 0 SnapINverter Technology HF transformer switchover Integrated data communication Smart Grid Ready Zero feed-in With power categories

More information

PACSystems* RX3i and Series 90-30

PACSystems* RX3i and Series 90-30 May 2012 PACSystems* RX3i and Series 90-30 Series 90*-30 Analog Output Module, Current/Voltage, 8 Channel, IC693ALG392 RX3i Analog Output Module, Current/Voltage, 8 Channel, IC694ALG392 The PACSystems

More information

3DD13005ED 主要参数 MAIN CHARACTERISTICS

3DD13005ED 主要参数 MAIN CHARACTERISTICS 主要参数 MAIN CHAACTEISTICS I C V CEO P C (IPAK/126/126S/220HF) P C (DPAK/TO-252) P C (TO-220C/262/263) NPN 型高压功率开关晶体管 HIGH VOLTAGE FAST-SWITCHING NPN POWE TANSISTO 4A 400V 40W 50W 75W 用途 节能灯 电子镇流器 高频开关电源

More information

SonoMeter 31 Energy Meters

SonoMeter 31 Energy Meters SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

Model UT233 OPERATING MANUAL

Model UT233 OPERATING MANUAL Model UT233 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure A. The Meter Front

More information

Installation & Operation Manual ELNet VIP

Installation & Operation Manual ELNet VIP Installation & Operation Manual ELNet VIP Electrical Measurements Table of Contents 1. Mechanical Installation... 1-3 2. Wiring diagram... 2-5 3. Specifications... 3-6 Technical Specifications... 3-6 Measuring

More information