100mm Recorders Specification Sheet
|
|
- Calvin Carter
- 5 years ago
- Views:
Transcription
1 0C 0M MODELS Up to Universal Input Channels High Visibility Display Annotation Data Archiving to PCMCIA Card Powerful Maths Pack RS/RS8 Communications 00mm Recorders Specification Sheet The 0 is high specification, 00mm strip chart recorder providing continuous recording for up to Process Variables. Information such as Channel descriptor, alarm setpoint and scale information can be viewed on a high resolution VFD (0) display. Process variables including messages can be archived to an optional removable media. These units can be programmed on site via the user interface or a configuration file can be transferred using a PCMCIA card. Display As well as displaying the process variables as a numeric value the 0 provides bargraph indication. The display will cycle through PV's configured to appear in the Display group. Additional information including the channel descriptor, scale information and alarm set points can be viewed using the operator key. C h a n n e l T a g U n i t s Configuration In order to prevent unauthorised access the configuration is password protected. Entry of the password provides access to the instrument configuration pages. It is possible to provide the operator access to certain parameters, for example you may require the operator to be able to change the chart speed or archiving interval. These fields can be enabled in the operator access menu. EUROTHERM FLEXIBLE SOLUTIONS
2 Operation Adaptive recording - multi-point version At slow chart speeds it is possible that the input circuit, between chart increments will pick up a spike or other brief disturbance in the measured signal, but that this disturbance will not appear on the chart, even though they may trigger an alarm. With adaptive recording enabled, if a sudden change in the input signal is detected, the recorder will place an additional dot on the chart without the chart being moved. This means that even at the lowest chart speed, unexpected signal changes can still be traced. Pen offset compensation - continuous pen version For continuous trace recorders the traces are separated in the time axis of the chart by mm, this results in simultaneous events being separated on the chart by mm. When enabled on the 0C, Pen offset compensation applies a delay to the pens, the time delay being determined by the selected chart speed, such that simultaneous events appear on the same time axis. Communications Supporting either RS or RS8 the Serial Communications board provides the means of establishing a link between a recorder and a host computer (using the Gould Modicon Modbus protocol), terminal emulator or Modem. Analogue Output If required, an input signal or the resulting calculation from a maths channel, can be retransmitted via an analogue output, to another device. Up to four analogue outputs can be fitted, each capable of generating a voltage or current output. Events As standard, there are six internal events, each can be triggered by up to two selected input sources. The number of events rises to when the Event Input board is fitted. Input sources can be logically ANDed or ORed allowing the use of multiple inputs. An example of the event input would be to provide external chart or logging control. Custom Curve This option allows the user to enter a Non standard linearisation table. The curve is entered as pairs of points (input (X), display (Y)), up to a maximum of pairs. Compensation Off Compensation On Review Package Offline printing and viewing is made possible by the use of the Review Software package. This package uses the packed data files from the recorders local storage media and imports them into a PC database. Data from one or more archive files can easily be viewed. This data can then be printed or exported as a CSV file. Review can also be configured to automatically Backup and Transfer the archived files via a modem. Modular design - All The modular design of the 00 Series allows for upgrades to be carried out in situ thus reducing downtime. Power supply unit (PSU) On/Off switch (Not all models) Option board slot Option board slot Option board slot Option board slot Exploded view Main (input) board Data archiving Two log groups are available for sending tabular data to the chart or PCMCIA card. Either log groups can be initiated to print on the chart. Log group can also be archived to a PC Card automatically at predetermined intervals. Data can be archived as either ASCII for use in spreadsheet, or Packed for viewing using Eurotherm Review software. Configuration Editor An offline configuration package that allows a recorder configuration to be set up on a PC and transferred either by the.mm jack plug or if fitted the Communications board. Alternatively a configuration file can be transferred using a PC card. Maths Pack The addition of the advanced maths pack option provides the 0 with derived channels and the ability to carry out complex calculations such as relative humidity and mass flow. Derived channels can be added to the log and display groups for trending and archiving as required.
3 TECHNICAL SPECIFICATION Input Board General Input types: Input type mix: Max no of inputs: 0C 0M Input ranges: dc Volts, dc millivolts,dc milliamps (with shunt), Thermocouple, / -wire RTD Contact closure (not ch ) >0ms User configurable 8 to +8mV 0 to +0mV 0. to + Volt to +0 Volts 0 to +00 Volts with attenuator Termination : Edge connector/terminal block Noise rejection (8 to Hz): Common mode: >0dB (channel to channel and channel to ground). Series mode: >0dB Maximum common mode voltage: 0 Volts continuous Maximum series mode voltage: mv at lowest range; Volts peak at highest range. Isolation (dc to Hz; EN00): Installation cat. II; Pollution deg. Channel to channel: 00V RMS or dc (double insulation) Channel to common electronics: 00V RMS or dc (double insulation) Channel to ground: 00V RMS or dc (basic insulation) Dielectric strength (BS EN00): ( minute type tests.) Channel to channel: 00V ac Channel to ground: 0V ac Insulation resistance: >0MΩ at 00V dc Input impedance: 8mV, 0mV and V ranges: >0MΩ; 0V range: 8.8kΩ Over voltage protection: 0 Volts peak (0V with attenuator) Open circuit detection: ±na max. Recognition time: 0msec Minimum break resistance: 0MΩ DC Input ranges Shunt/attenuator: Externally mounted resistor modules Additional error due to shunt: 0.% of input Additional error due to attenuator: 0.% of input Performance: See table Low High Resolution Maximum error Worst case temperature Range Range (Instrument at 0 C) performance 8mV 8mV.μV 0.08% input + 0.0% range 80ppm of input per C 0mV 0mV.μV 0.08% input + 0.0% range 80ppm of input per C 0.V V μv 0.08% input + 0.0% range 80ppm of input per C V 0V 0μV 0.% input % range ppm of input per C Table DC performance Thermocouple data Temperature scale: ITS 90 Bias current: 0.0nA Cold junction types: Off, internal, external, remote CJ error: C; instrument at C CJ rejection ratio: 0: minimum Remote CJ: Via any user-defined channel Upscale/downscale drive: High, low or none selectable for each thermocouple channel Types and ranges: See table T/C Type Overall range ( C) Standard Max linearisation error B 0 to +80 IEC 8. 0 to 00 C:. C 00 to 80 C:0.0 C C 0 to +00 Hoskins 0. C D 0 to +9 Hoskins 0.08 C E 0 to +000 IEC C G 0 to + Hoskins 0.0 C J 0 to +00 IEC C K 0 to + IEC C L 00 to +900 DIN00: C (To IPTS8) N 0 to +00 IEC C R 0 to +8 IEC C S 0 to +8 IEC C T 0 to +00 IEC C U 00 to +00 DIN00: C Ni/NiMo 0 to +0 Ipsen 0. C Platinel 0 to +0 Englehard 0.0 C Table Thermocouple types and ranges Resistance inputs Ranges (including lead resistance): 0 to 0Ω, 0 to 00Ω, 0 to kω Influence of lead resistance: Error: negligible; Mismatch: Ω/Ω Temperature scale: ITS90 Resolution and performance: See Table RTD types and ranges: See Table Low High Resolution Maximum error Worst case temperature Range Range (Instrument at 0 C) performance 0Ω 0Ω mω 0.0% input + 0.0% range ppm of input per C 0Ω 00Ω mω 0.0% input + 0.0% range ppm of input per C 0Ω 000Ω 8mΩ 0.09% input + 0.0% range ppm of input per C Table Resolution and performance for resistance inputs RTD type Overall range ( C) Standard Max linearisation error Cu0 0 to +00 General Electric Co 0 0 C JPT00 0 to +0 JIS C 0: C Ni000 0 to +0 DIN0: C Ni0 0 to +0 DIN0: C Pt00 00 to +80 IEC 0.0 C Pt00A 00 to +00 Eurotherm 0.09 C Recorders SA Pt to +80 IEC 0.0 C Table RTD types and ranges INSTALLATION CATEGORY II The rate impulse voltage for equipment on nominal 0V mains is 00V. POLLUTION DEGREE Normally, only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation shall be expected Recorder Board types Standard: Universal input / control board Options: - Change-over relay output board Normally open relay O/P board Normally closed relay O/P board Analogue output board ( channel) Event input board Communications board Transmitter power supply Environmental Performance Temperature limits: Operation: 0 to 0 C Storage: 0 to + 0 C Humidity limits: Operation: % to 80% RH (non-condensing): Protection: Shock: Vibration: Altitude (max.): Storage: % to 90% RH Door and Bezel: IP Sleeve: IP0 Transmitter PSU cover: IP0 BS EN00 g peak at 0 Hz to 0Hz 000 metres Power requirements Line voltage: Standard: 90 to V at to Hz Enhanced interrupt protection: 90 to V at to Hz Low voltage: 0 to V dc or 0 to V ac ( to 00 Hz) Power (Max): 00 VA Fuse type: Not user accessible Interrupt protection: Standard: 0ms at % max. instrument load Enhanced: 0ms at % max. instrument load Electromagnetic compatibility (EMC) Emissions: BS EN008- Immunity: BS EN008- Electrical safety: To EN00: Installation category II; Pollution degree Physical Panel mounting: Bezel size: Panel cutout dimensions: Depth behind bezel rear face: Weight: Panel mounting: DIN00 x mm. 8 x 8 (both mm) 0 mm (No terminal cover); mm (standard terminal cover) mm (long terminal cover closed) 90mm (long terminal cover open) <.kg Vertical ±0 C
4 TECHNICAL SPECIFICATION (continued) Recorder (continued) Printing System 0C Pen type: Disposable fibre-tipped pens Pen resolution: 0. mm Trace colours: See Table Pen life:.km (channel);. x 0 dots (annotator) Update rate: 8 Hz Response time (max): second Characters per line: Channel (top) (bottom) Annotator Colour blue red green violet black Table 0C Trace colours Printing System 0M Pen type: Six nib cartridge Pen resolution: 0. mm Trace colours: See Table Pen life:. x 0 dots per colour Update rate: Hz Response time (max): pass every. seconds Characters per line: Channel Colour violet red black green blue brown Paper transport Type: Chart speeds: Chart type: Table 0M Trace colours Stepper motor driving sprocket tube 0C 0 to,000 mm/hr; 0 to in/hr 0M 0to 00 mm/hr;0 to in/hr Standard metre z-fold Option metre roll Options All isolation figures are Installation category II and Pollution degree Modbus (RS/RS/RS8) Communications Isolation: Terminal to ground: 00V RMS/dc (basic insulation) Protocol: Gould Modicon Modbus RTU Transmitter Power Supply Output voltage: or x V dc (nom) outputs Isolation (dc to Hz; BS EN00): Channel to channel: 00V RMS or dc (double insulation) Channel to ground: 00V RMS or dc (basic insulation) Relay outputs Maximum switching power: 00VA Maximum breaking current: Amps within above power ratings Maximum contact voltage: 0V within above power ratings Maximum dc ratings: See Graph Isolation (dc to Hz; BS EN00): Contact-contact: 00V RMS or dc (double insulation) Contact to ground: 00V RMS or dc (basic insulation) Estimated life* 0,000,000 operations * With resistive loads. With inductive loads, derate according to Graph, in which: Contact life = resistive life x F or F where F = measured on representative examples and F = typical values according to experience Reduction Factor F 0.9 F F Graph Derating curves F Power factor (cos φ) Graph DC ratings Analogue (transmission) outputs Output ranges (user configurable): Voltage: 0 to 0V (source ma max) Current: 0 to 0mA (max load resistance: kω) Update rate Hz Step response (0% to,90%): 0msec Linearity: 0.0% of hardware range Performance: See Table Isolation: Channel to channel: 00V RMS or dc (double insulation) Channel to ground: 00V RMS or dc (basic insulation) Performance in instrument at 0 C Range Accuracy Temperature Drift 0 to0v 0.% of range ±0.mV +0.0% of reading per C 0 to0v 0.% of range ±0.μA +0.0% of reading per C Table Analogue output performance Max. DC load breaking capacity resistive load DC current (Amps) 0C, 00G Seismic Tested to IEE 98 IEEE recommended practice for Sieimic qualification of class E equipment for Nuclear Power Generating Stations DC Voltage (Volts) inductive load (L/R = 0msec) Maths pack Number of derived channels: (, 00G) Level functions Off Subtract Modulus Constant Multiply Add Divide Level functions (additional to level ) Square root Rate of change Third order polynominal Low select Channel average Sample and hold Relative humidity Stopwatch DV group average Channel min F value Time stamp Rolling average DV group latching min Linear mass flow 0 correction e x DV group continuous min Square root mass flow Time stamp log n Channel max Zirconia probe Percentile 0 X DV group latching max Switch Log0 DV group continuous max High select Event inputs Number of inputs: discrete or binary coded inputs + chart synch Isolation: Event input to ground: 00V RMS or dc (double insulation) Chart drive to ground: 00V RMS or dc (double insulation) Event input to chart drive: 00V RMS or dc (double insulation) Event input to Event input: 0V Recognition levels: Low: 0V to +0.8V High: to 0V Maximum frequency: Events: Hz Pulse counting: Hz Minimum pulse width:.ms Chart synchronization: Chart speed: Selected speed at 00 pulses/sec Maximum pulse rate: 0 pulses per second Duty cycle: 0 to 80% Customer linearisation Number of tables available: One Number of point pairs: Mechanical installation mm mm Front view 8mm x 8mm ( mm) Panel cutout Details mm Min. inter-recorder distance: mm Note STC = Short terminal cover (standard fit) LTC = Long terminal cover (option) 90mm (LTC open) mm (LTC closed) mm (STC) 0mm 00mm Case clamp Maximum panel thickness mm View on right hand side View on under side (STC shown) mm Alternative location for case clamp mm.mm
5 Input board signal wiring V+ V I + Shunt assembly + Attenuator assembly + Closure must last 0C, 0M >0ms 00G >0ms DC V ( V to +0V) DC mv Thermocouples DC ma DC V ( 0 to +00V ) -wire resistance thermometer -wire resistance thermometer Potentiometer Contact Closure (0 not Ch 00G not Ch or ) Shunt assembly 00Ω = LA9UK0 0Ω = LA9UK Attenuator assembly LA80 Supply voltage and input board termination 0C Earth Line (dc+) Neutral (dc ) Line input: 90 to V ( to Hz) OR, if low voltage option fitted: 0 to V dc peak ac ( to 00Hz) Safety cover not shown for clarity DC polarity not important, but + terminal fused Option board(s) M Earth Line (dc+) Neutral (dc ) Line input: 90 to V ( to Hz) OR, if low voltage option fitted: 0 to V dc peak ac ( to 00Hz) Safety cover not shown for clarity DC polarity not important, but + terminal fused Option board(s) Option board(s) Option board (optional) Input board Ch Ch 8 Ch 9 Ch 0 Input board Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Ch Option wiring Relay ouput and Profibus communications termination Event input, retransmission and Modbus communications termination Option board No Option board No Option board No Option board No NC C NC C NC C C C C C R R R R R R R Option board No Option board No CSC C CS TxA TxB 0V V RxA RxB Option board No Option board No R R R R Input board Shield Shield 0V V RXD TXD RXD+ TXD+ C/C Vp A/A B/B + + Tx 0V V Rx Ch Ch (DTR used only with Modbus) Input board DTR Option board No Changeover Relays (R) option Option board No Normally Open Relays (R) option Option board No Normally Closed Relays (R) option Option board No Profibus Comms Option board No Even input option Option board No Modbus comms (RS8) Option board No Retransmission output option Option board No Modbus comms (RS)
6 Eurotherm: International sales and service Understanding and providing local support is a key part of Eurotherm's business. Complementing worldwide Eurotherm offices are a whole range of partners and a comprehensive technical support team to ensure you get a service you will want to go back to. AUSTRALIA Sydney Eurotherm Pty. Ltd. T (+ ) F (+ ) E info.au@eurotherm.com AUSTRIA Vienna Eurotherm GmbH T (+ ) 980 F (+ ) 980 E info.at@eurotherm.com BELGIUM & LUXEMBOURG Moha Eurotherm S.A/N.V. T (+) F (+) 8 08 E info.be@eurotherm.com BRAZIL Campinas-SP Eurotherm Ltda. T (+9) 0 F (+9) 0 E info.br@eurotherm.com DENMARK Copenhagen Eurotherm Danmark AS T (+ 0) 0 F (+ 0) 0 E info.dk@eurotherm.com FINLAND Abo Eurotherm Finland T (+8) 000 F (+8) 00 E info.fi@eurotherm.com FRANCE Lyon Eurotherm Automation SA T (+ 8) 00 F (+ 8) 90 E info.fr@eurotherm.com GERMANY Limburg Eurotherm Deutschland GmbH T (+9 ) 980 F (+9 ) 989 E info.de@eurotherm.com HONG KONG & CHINA Eurotherm Limited North Point T (+8 ) 88 F (+8 ) 8008 E info.hk@eurotherm.com Guangzhou Office T (+8 0) F (+8 0) 8 8 E info.cn@eurotherm.com Beijing Office T (+8 0) 80 F (+8 0) 809 E info.cn@eurotherm.com Shanghai Office T (+8 ) 88 F (+8 ) 8 E info.cn@eurotherm.com INDIA Chennai Eurotherm India Limited T (+9 ) 99 F (+9 ) 98 E info.in@eurotherm.com IRELAND Dublin Eurotherm Ireland Limited T (+ ) 9800 F (+ ) 900 E info.ie@eurotherm.com ITALY Como Eurotherm S.r.l T (+9 ) 9 F (+9 ) 9 E info.it@eurotherm.com KOREA Seoul Eurotherm Korea Limited T (+8 ) 80 F (+8 ) 808 E info.kr@eurotherm.com NETHERLANDS Alphen a/d Rijn Eurotherm B.V. T (+ ) F (+ ) 0 E info.nl@eurotherm.com RWAY Oslo Eurotherm A/S T (+ ) 90 F (+ ) 80 E info.no@eurotherm.com POLAND Katowice Invensys Eurotherm Sp z o.o. T (+8 ) 800 F (+8 ) E info.pl@eurotherm.com SPAIN Madrid Eurotherm España SA T (+ 9) 00 F (+ 9) 909 E info.es@eurotherm.com SWEDEN Malmo Eurotherm AB T (+ 0) 800 F (+ 0) 8 E info.se@eurotherm.com SWITZERLAND Wollerau Eurotherm Produkte (Schweiz) AG T (+ ) 800 F (+ ) 80 E info.ch@eurotherm.com UNITED KINGDOM Worthing Eurotherm Limited T (+ 90) 800 F (+ 90) 98 E info.uk@eurotherm.com U.S.A. Leesburg VA Eurotherm Inc. T (+ 0) 0000 F (+ 0) 9 00 E info.us@eurotherm.com ED Copyright Eurotherm Limited 00 Invensys, Eurotherm, the Eurotherm logo, Chessell, EurothermSuite, Mini8, Eycon, Eyris and Wonderware are trademarks of Invensys plc, its subsidiaries and affiliates. All other brands may be trademarks of their respective owners. All rights are strictly reserved. No part of this document may be reproduced, modified, or transmitted in any form by any means, nor may it be stored in a retrieval system other than for the purpose to act as an aid in operating the equipment to which the document relates, without the prior written permission of Eurotherm limited. Eurotherm Limited pursues a policy of continuous development and product improvement. The specifications in this document may therefore be changed without notice. The information in this document is given in good faith, but is intended for guidance only. Eurotherm Limited will accept no responsibility for any losses arising from errors in this document. Part No. HA08 Issue 0C, 0M 00mm Recorder Specification Sheet Printed in England.0
100mm Recorders Specification Sheet
4103C, 4103M MODELS 100mm Recorders Specification Sheet The 4103 is a high specification, 100mm strip chart recorder, providing continuous recording for up to 6 Process Variables. Information such as Channel
More informationPaperless Graphic Recorder Specification Sheet
6100E MODEL 5.5 Colour TFT touchscreen display USB plug & play 8MB non-volatile flash memory 125ms parallel sampling/1s update Compact Flash Ethernet TCP/IP Paperless Graphic Recorder Specification Sheet
More informationnanodac Recorder/Controller Virtual Channels using the nanodac Recorder/Controller Application Note imagine bigger better smaller MODEL Product
nanodac Recorder/Controller MODEL Virtual Channels using the nanodac Recorder/Controller Application Note Product The nanodac recorder/controller provides combined recording and control in a single, compact
More informationEUROTHERM FLEXIBLE SOLUTIONS SERIES CONTROLLERS... Best in class Industrial Control
EUROTHERM FLEXIBLE SOLUTIONS 2000 SERIES CONTROLLERS... Best in class Industrial Control Ultimate performance Built on our experience of design and applications knowledge spanning more than 40 years, the
More informationMEMOCAL 2000/2000S. Hand-held calibrator
MEMOCAL 2000/2000S Hand-held calibrator MEMOCAL 2000 Very low temperature drift (0.1µV/ C) Accuracy: 0.015% of span Power supply: standard AA size battery (Alkaline, NiCd or Ni-MH) Measurement & generation
More informationDPR100 C/D PEN AND MULTIPOINT 100 mm DIGITAL RECORDERS
PEN AND MULTIPOINT 100 mm DIGITAL RECORDERS EN0I-6021 06/2003 PRODUCT SPECIFICATION SHEET PRODUCT DESCRIPTION The DPR 100 C and D recorders are designed to meet the recording needs for most recording applications.
More informationGeneral Specifications
General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.
More information- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION
ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS
More informationEasy-to-read in either English, French, or German; 20-digit, 2-line display; 6-channel simultaneous display possible
PHA & PHC STRIP CHART RECORDERS WITH BRILLIANT SIX-COLOR PRINTING Why use dot-matrix or fiber-tip pen printing when Fuji Electric s patented, cutting-edge recording technology offers an affordable inkjet
More informationHigh-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals
Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building
More informationSHIMADEN DIGITAL INDICATORS
Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large
More informationVIEW RECORDERS SPECIFICATIONS
SPECIFICATIONS Input points: µr1000:1,2,3,4,(pen),6(dot)point µr1800:1, 2, 3, 4, (pen), 6, 12, 18, and 24 (dot) point Input signals, range, and measurement range limits: Input RANGE Range 20 mv 20.00 to
More informationPaperless Recorder PR20
Technical Information TI 075R/24/ae Paperless Recorder PR20 Economical and time saving recorder operates without the need for paper or pens and is exceedingly simple to operate Application Areas Technological
More informationGeneral Specifications
General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with
More informationTemperature and Process Controllers Specification Sheet
piccolo ontroller SERIES Temperature and Process ontrollers Specification Sheet Precision PID control Easy to use and apply High reliability and quality Three year warranty Ramp-soak timer and soft start
More informationPROCESS & TEMPERATURE CONTROLLERS
PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs
More informationC520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters
C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters The 520 transmitters are universal, isolated, dual-input temperature transmitters with additional voltage and resistance
More informationµr SERIES RECORDERS VIEW RECORDERS 4365 & 4375 Recorders FUNCTIONS FEATURES
4365 & 4375 Recorders VIEW RECORDERS Splash and dust-proof door permits use even in poor environments. (Based on DIN 40050-IP54). Depth is a mere 220 mm, enabling significant instrument panel space savings.
More informationHigh Performance Process & Temperature Controllers
C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal
More informationDigital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel
Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel Digital-analogue meters of LEL-NA series with a multicolour bargraph have a universal input destined
More informationExcellent low-cost Process & Temperature Controllers
C22 C62 C82 C83 Excellent low-cost Process & Temperature Controllers C72 C42 R22 01. High Quality LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. The Fast Sampling Rate in 200
More informationGeneral Specifications
General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring
More informationTemperature/Process Controllers Specification Sheet
3200 MODELS Ideal for : Plastic extrusion Hot runners Thermoforming Ovens Chillers Trace heating Stress relieving Features : 8 Segment programmer Heater failure detection Current monitoring Internal timer
More informationGeneral Specifications
General Specifications GS 0F01D0E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision 1/8 DIN alarm instrument provided with
More informationGeneral Specifications
General Specifications GS 0F01D01E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision alarm instrument provided with universal
More informationGeneral Specifications
General Specifications Model UM350 Digital Indicator with Alarms GS 05F0D00E General Model UM350 Digital Indicator with Alarms is a precision alarm instrument with universal input. For excellent monitoring
More informationGeneral Specifications
General Specifications Model UT, UT Temperature Controller GS CE-E GENERAL UT series temperature controllers provide only the functions and size you require for your application. /6 DIN sizes is available.
More informationmemocal certo Multifunction Documenting Process Calibrator Accuracy ±0.01% rdg for all TC s and RTD s Complies with AMS2750 (secondary standard)
memocal certo Multifunction Documenting Process Calibrator Accuracy ±0.01% rdg for all TC s and RTD s Complies with AMS2750 (secondary standard) Light, Rugged and Ergonomic for Field Use, with Anti-shock
More informationGeneral Specifications
General Specifications Model UM330 Digital Indicator with Alarms GS 05F0D00E General Model UM330 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent
More informationEssential Power Control
Essential Power Control EPack TM Lite-PH Compact SCR Power Controllers Simplicity Without Compromise On Performance Product at a Glance The end user, the machine builder or the system integrator expects
More informationHYBRID RECORDER OUTLINE
Specifications Sheet No.SPEC-33E (st Edition) RM0C HYRID RECORDER OUTLINE RM0C is 00mm calibrated hybrid recorder in a 44x44 DIN front panel and short depth of 50mm case housing. The recorder has versatility
More informationSpecifications. 744 Users Manual
80T-150U Temperature Probe 80PK series thermocouples 80i-410 Clamp-on DC/AC Current Probe 80i-1010 Clamp-on DC/AC Current Probe 80i-500s Clamp-on AC Current Probe (requires the Y9108 adapter) 80i-1000s
More informationC330 / C330X PC-Programmable Universal, 2-wire Transmitter
C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and
More informationC1901 Single Pen Circular Chart Recorder. C1901 a rugged, reliable recorder for all single channel recording applications
Data sheet DS/ EN Rev. F a rugged, reliable recorder for all single channel recording applications Universal process input ma, mv, V, thermocouples and resistance Signal linearization full range of linearizers
More informationChapter 6 Specifications
Chapter 6 Specifications DC Characteristics Function Range [2] Test Current or Burden Voltage DC Voltage DC Current Resistance [6] 24 Hour [3] T CAL ±1 Accuracy Specifications: ± (% of reading + % of range)
More informationPSG series 2000 Iss5 10/25/00 11:20 AM Page 1 SERIES SELECTION GUIDE. Industrial Temperature and Process Controllers ALL SOLUTIONS.
PSG series 000 Iss5 0/5/00 :0 AM Page SERIES 000 SELECTION GUIDE Industrial Temperature and Process Controllers ONE RANGE ALL SOLUTIONS abc PSG series 000 Iss5 0/5/00 :0 AM Page ONE RANGE ALL SOLUTIONS
More informationDIGEM f 96 x 48 EK. Applications. Description
3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel
More informationS200 I/O System Units
S200 I/O System Units S200 I/O is a range of cost effective I/O units which are bus compatible with S200L I/O and can be mixed with them in any order on the same DIN rail. The S200 I/O System features
More informationr ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R
170.ADD.LFS.RB0 0,8.011-98/B r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R INDEX ASSEMBLING... 1 Warning... 1 General assembling information... 1 Wall mounting... 1 Omega din rail mounting... 2 MECHANICAL
More informationTemperature Controller
Temperature Controller 1/8 IN - 48 x 96mm Platinum Series X400 Line Cost Effective Solutions This 48x96mm size controller of the Platinum Series, provides a high degree of functionality and reliability
More informationDIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES
Digital Thermometer High-Accuracy Reference Junction Compensation: Compensation accuracy (±0.2 C) Input terminals are provided on both front and rear panels, and an input site is switch selectable. The
More informationGeneral Specifications
General Specifications SR Recorder LF 4D8B-4U The SR is a small compact recorder using a mm (4 inch) wide paper. The family consists of,,3 pen and a 6 dot model. Its input is universal, which means that
More informationHigh-precision process calibrator Model CED7000
Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry
More informationMODEL: M2XU MODEL: M2XU [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and
More informationGeneral Specifications
General Specifications µrs800 Recorders GS0H0B0-00E µrs800 recorders are compact recorder with 80mm recording width, available as standard in,, 3, -pen, and 6,, 8, -point dot-printing models. These recorders
More informationDigital indicator for panel mounting With multi-function input Model DI25
Accessories Digital indicator for panel mounting With multi-function input Model DI25 WIKA data sheet AC 80.02 Applications Plant construction Machine tools Plastics technology and processing Ventilation
More informationGeneral Specifications
General Specifications µrs000 Recorders µrs000 recorders are compact recorder with 00mm recording width, available as standard in -pen, 2-pen, 3- pen, 4-pen, and 6-point dot-printing models. These recorders
More informationDIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS
Digital Thermometer 23 88 350 mm 3 kg (8-5/8 3-/2 3-3/4" 6.6 lbs) The Digital Thermometer has 6 ranges of temperature sensors and measuring functions of DC V and Ω. YOKOGAWA-original A/D converter (feedback
More informationONE CALIBRATOR ONLY MAIN FEATURES:
ONE CALIBRATOR ONLY The MEMOCAL 2000 is a lightweight versatile, portable, hand-held calibrator developed to solve two different and coexisting customer needs: field calibration (maintenance) and laboratory
More informationPOINTAX 6000L2 Point Recorder
GOSSEN METRAWATT CAMILLE BAUER Special Features 6 measuring channels Last printed point visible from front Electrically isolated, earth-free measuring channels Process signals ranging from 0/4... 20 ma,
More informationNPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.
REGULATION AUTOMATIC SYNCHRONIZER for GENERATOR NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. NPRG870 adds
More informationCALYS 150. Advanced documenting multifunction calibrator thermometer
Advanced documenting multifunction calibrator thermometer , most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer
More informationOPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9211E 4-Channel Thermocouple Input Module
OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9211E 4-Channel Thermocouple Input Module This document describes how to use the National Instruments 9211E and includes dimensions, terminal assignments, and
More informationPowerLogic power-monitoring units. PM700 series power meter. Technical data sheet
PowerLogic power-monitoring units PM700 series power meter Technical data sheet 2009 Functions and characteristics The PowerLogic PM700 series power meter offers all the measurement capabilities required
More informationCALYS Transportable documenting multifunction calibrator with high accuracy 0.01%
Transportable documenting multifunction calibrator with high accuracy 0.01% CALYS 1200 is the ideal solution to simultaneously simulate and measure with a high accuracy of 0.01%: voltage, current, resistance,
More informationMODEL: M6SXU MODEL: M6SXU [1][2] [3][4]
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)
More informationDigital Indicator DS 96/48 PK
Data Sheet 10/33-2.1-EN Digital Indicator DS 9/48 P Digital Indicator DS 9/48 PK Inputs Direct current, direct voltage Thermocouple Resistance thermometer Programmable via front keys or PC software Limit
More informationcontrol & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS
S E N S O R S PROGRAMMABLE SENSOR CONTROLLER TX9044 COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS Analogue sensors, temperature devices, frequency inputs and digital sensors direct fingertip
More informationMICRO-CONTROLLER X (48 48 mm)
PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature
More informationNPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator
REGULATION Automatic Synchronizer for Generator NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. NPRG870 adds
More informationMODEL: R30US4. Remote I/O R30 Series
Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable
More informationIndustrial Modbus I/O Modules
Industrial Modbus I/O Modules Modbus I/O Modules Introduction & Features Digital Input / Output Modules Analog Input / Output Modules Modbus I/O Modules The Best Choice For Your SCADA Applications Introduction
More informationTemperature measurement TMD 832 head transmitter
Technical information TI 062R/09/en Mat.-Nr. 510 00782 Temperature measurement TMD 832 head transmitter SMART head transmitter with HART protocol for RTD, Thermocouple and mv input signals Applications
More informationhigh accuracy tester-calibrator PJ 6301
high accuracy testercalibrator PJ 6301 PJ6301 is a highaccuracy instrument: ± 0.005% with 600,000 measuring counts on voltage and current ranges; for thermocouple and for RTD measurement resolution. Simultaneous
More informationA6500-UM Universal Measurement Card
Specifications Sheet A6500-UM Universal Measurement Card The A6500-UM Universal Measurement Card is a component of the CSI 6500 ATG machinery protection system. The card is equipped with 2 sensor input
More informationTemperature Transmitters
Temperature Transmitters measuring monitoring analysing KM O O Wide supply voltage range: 7.5... 5 V DC O O Operation, visualisation and maintenance via PC Universal setting with HART protocol T O O Fault
More informationCALYS 150. Advanced documenting multifunction calibrator thermometer
Advanced documenting multifunction calibrator thermometer, most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer
More informationAgilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size
Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size Data Sheet Features 1-Slot, C-size, message-based DCV, ACV, DCI, ACI, 2/4-wire Ω, frequency, period NULL, MIN/MAX, LIMIT, db, dbm 1000 reading/s
More informationINPUT RESISTANCE OR CLAMP VOLTAGE. 2 Years 23 C ±5 Voltage mv 3 10 nv > 10 G
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 www.keithley.com Model 2010 Low-Noise Multimeter Specifications DC CHARACTERISTICS CONDITIONS: MED (1 PLC) 1 or SLOW (5 PLC)
More informationADAM 4000/4100 Series
ADAM 4000/4100 Series Common Dimensions Communication RS-485 (2-wire) to host Speeds: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps (ADAM-4080, ADAM-4080D only support up to 38400 bps) Max. communication
More informationManual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.
Manual Title: 550A Getting Started Supplement Issue: Part Number: 415509 Issue Date: 9/18 Print Date: November 01 Page Count: 19 Revision/Date: This supplement contains information necessary to ensure
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More information8588A Reference Multimeter
8588A Reference Multimeter Product Specifications March 2019 Rev. A 2019 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of
More information6/12/24 Dot Printing Model Smart Recorder SRF206/212/224
No. CP-SS-E // Dot Printing Model Smart Recorder SRF0// The Smart Recorder SRF 0// Dot Printing Model accepts DC voltage, thermocouple, resistance temperature detector (RTD), communications and ON/OFF
More informationData Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V
Agilent M9185A PXI Isolated D/A Converter Data Sheet 8/16-Channel 16-bit, ±16 V DISCOVER the Alternatives...... Agilent MODULAR Products Overview Introduction The Agilent M9185A is a digital/analog converter
More informationManual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.
Manual Title: 5502E Getting Started Supplement Issue: 3 Part Number: 4155211 Issue Date: 9/18 Print Date: November 2012 Page Count: 12 Revision/Date: This supplement contains information necessary to ensure
More informationAC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet
AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet Low DC drift and noise allows improved low-level current measurements 3rd party safety certification Applications
More informationSHIMADEN DIGITAL INDICATOR
Shimaden, Temperature and Humidity Control Specialists C %RH Series SD24 & KR16A SHIMADEN DIGITAL INDICATOR BASIC FEATURES ohigh Accuracy ±0.1% FS+1 digit o1/1000ºc Resolution Indication Possible (Pt input
More informationUni-Mux XQL Multi-Channel Data Acquisition Module
Uni-Mux XQL Multi-Channel Data Acquisition Module Uni-Mux XQL Multi-Channel Data Acquisition Module * 8 channel differential inputs. * 16 channel single ended inputs. * User programmable via P.C. software.
More informationDIN rail mounting temperature controller with current transformer input deltadue series D1 line
BT.. D/E S E R I E S DIN rail mounting temperature controller with current transformer input deltadue series D line The controller with load control The deltadue series includes a powerful DIN rail mounting
More informationGeneral Specifications
General Specifications MW100-E-1X/X/X/S15 Special Edition 1. MW100/S15 Hardware Specification MW100 Logging type Mainly standalone measurement and distributed remote measurement Style No. S3 Maximum number
More information02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
More information02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
More informationDIGITAL PROGRAM CONTROLLER
KP1000 SERIES DIGITAL PROGRAM CONTROLLER The KP1000 series is a 96x96mm digital program controller with the indicating accuracy of ±0.1%, the control cycle of approximately 0.1 seconds and maximum 19 program
More informationMULTIFUNCTION GRAPHICAL UNIT MGU 800
MULTIFUNCTION GRAPHICAL UNIT MGU 800 For display, recording and evaluation of process instruments signals (level, temperature, pressure, etc.) 3.5" TFT display, multi-language menu Variety of possible
More informationDatasheet. SDM3065X Digital Multimeter. Product Overview. Main Feature. Application fields. Main Function
Datasheet SDM3065X Digital Multimeter Product Overview SDM3065X is a 6 ½ digit digital (2,200,000 count) multimeter incorporating a dual display and is especially well suited for the needs of high-precision,
More informationAIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)
Model:PFXLM4B01DDK PFXLM4B01DDC PFXLM4B01DAK PFXLM4B01DAC LT4000M Rear module Model Name Indication PFXLM4B01 D * * (1) (2) (3) (4) Notice to our valued customers who use LT4000M series (analog model)
More informationAC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet
AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet Low DC drift and noise allows improved low-level current measurements 3rd party safety certification 2 Requires
More informationCALYS 100. Field precision documenting multifunction calibrator
Field precision documenting multifunction calibrator is a precision documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench
More informationFluke 8845A/8846A Digital Multimeters Extended Specifications
Fluke 8845A/8846A Digital Multimeters Extended Specifications The Fluke 8845A and 8846A 6.5 digit precision multimeters have the precision and versatility to handle your most demanding measurements, on
More informationSHIMADEN DIGITAL INDICATORS
Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16 & SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright
More informationMICRO-CONTROLLER X (96 96 mm)
PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature
More informationCALYS 50. Field multifunction calibrator for basic use
Field multifunction calibrator for basic use CALYS 50 field multifunction calibrator is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field
More informationCALYS 75. Field documenting multifunction calibrator
Field documenting multifunction calibrator is a field documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries.
More informationSefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website
Make sure to visit our Website http://wwwseframfr Sefram Sefram SEFRAM A new family of thermal recorders 6 to 36 channels 6 to 36 analogue channels Measurement boards : - 6 isolated channels universal
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationGeneral Specifications
General Specifications Model CA51/ CA71 HANDY CAL calibrator GS 77W02A01-01-E GENERAL The CA51/CA71 HANDY CAL calibrators are comprehensive generating/measuring instruments for all
More information10 GHz Linear Amplifier PSPL5866 Datasheet
10 GHz Linear Amplifier PSPL5866 Datasheet The PSPL5866 amplifier has been designed to minimize the variations in gain and phase and to operate at very low frequencies. The PSPL5866 includes internal temperature
More informationHP 34401A Specifications 8
8 HP 34401A Specifications 8 DC Characteristics DC Characteristics Accuracy Specifications ± ( % of reading + % of range ) [ 1 ] Function Range [ 3 ] Test Current or Burden Voltage 24 Hour [ 2 ] 23 C ±
More informationv v PMA With numerous functions and robust construction, the KS 3930 A/B line recorders are ideal for universal industrial applications.
v v PMA Line recorder KS 3930 A KS 3930 B Galvanically isolated input channels for simple connection Measuring and recording range freely configurable Maintenance-free recording system Universal cassette
More information