Fluke 8845A/8846A Digital Multimeters Extended Specifications

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Fluke 8845A/8846A Digital Multimeters Extended Specifications"

Transcription

1 Fluke 8845A/8846A Digital Multimeters Extended Specifications The Fluke 8845A and 8846A 6.5 digit precision multimeters have the precision and versatility to handle your most demanding measurements, on the bench or in a system. These meters are both high performance and feature rich, yet also remarkably easy to use. Features at a glance 6.5 digit resolution Basic V dc accuracy of up to % (1 yr.) Dual display 100 µa to 10 A current range, with up to 100 pa resolution Wide ohms ranges from 10 W to 1 GW with up to 10 µw resolution 2 x 4 ohms 4-wire measurement technique Both models measure frequency and period 8846A also measures capacitance and temperature USB memory drive port (8846A) Fluke 45 and Agilent 34401A emulation Graphical display Trendplot paperless recorder mode, statistics, histogram CAT I 1000 V, CAT II 600 V These digital multimeters perform the functions you would expect to see in a multifunction DMM, including measuring volts, ohms, and amps, with performance that exceeds expectations. Basic V dc accuracy of up to %, 10 A current range, and a wide ohms range from 10 W to 1 GW with up to 10 μw resolution give you an unbeatable combination of measurement capability. You can also use the 8845A and 8846A to measure temperature, capacitance, period, and frequency the functions of a counter, capacitance meter, and thermometer are built in for unparalleled versatility. Extend the meters utility even more with their graphical display modes, including Trendplot paperless recorder mode, statistics and histograms features you won t find on other multimeters. Of course, these meters are also durable and dependable, features you expect from any Fluke meter. This unique combination of features and performance makes the 8845A and 8846A an unbeatable value for a wide variety of applications, including manufacturing test, research and development, and service.

2 Power Voltage 100 V Setting V to 110 V 120 V Setting V to 132 V 220 V Setting V to 242 V 240 V Setting V to 264 V Hz to 440 Hz. Automatically sensed at power-on. Power Consumption VA peak (12 Watt average) Dimensions Height mm (3.46 in.) Width mm (8.56 in.) Depth mm (11.7 in.) Weight kg (8.0 Ibs.) Shipping Weight kg (11.0 lbs) Display Vacuum Fluorescent Display, dot matrix Environment Operating... 0 C to 55 C Storage C to 70 C Warm Up... 1 hour to full uncertainty specifications Relative Humidity (non-condensing) Operating... 0 C to 28 C <90 % 28 C to 40 C <80 % 40 C to 55 C <50 % Storage C to 70 C <95 % Altitude Operating... 2,000 Meters Storage... 12,000 Meters Vibration and Shock...Complies with Mil-T-28800F Type III, Class 5 (Sine Only) General Specifications Safety Designed to comply with IEC :2000-1, UL A1, CAN/CSA-C22.2 No , CAT I 1000V/CAT II 600V EMC Designed to comply with IEC : (EMC) when used with shielded communications cables. This Meter has shown susceptibility to radiated frequencies greater than 1 V/m from 250 to 450 MHz in the 100 μa range. Triggering Samples per Trigger...1 to 50,000 Trigger Delay...0 S to 3600 S; in 10 µs increments External Trigger Delay...<1 ms External Trigger Jitter...<500 µs Trigger Input...TTL Levels Trigger Output...5 V maximum. (Open collector) Memory 8845A...5,000 measurements, Internal only 8846A...5,000 measurements, Internal and up to 2 Gigabyte capacity with USB memory module (available separately. see Accessories ) through front-panel USB port Math Functions Zero, dbm, db, MX+B, Trend-plot, Histogram, Statistics (min/max/average/standard deviation), and Limit Test 8845A and 8846A Fluke Corporation 1

3 Electrical Input Protection V all ranges Overrange...20 % on all ranges except 1000 V dc, 1000 V ac (8846A), 750 V ac (8845A), Diode, and 10 A ranges Remote Interfaces RS-232 (RS-232 to USB cable available to connect the Meter to a PC USB port. See accessories) IEEE LAN Warranty One year Electrical Specifications Accuracy specifications are valid for 6½ digit mode after at least a 1-hour warm-up with Auto Zero enabled. 24-hour specifications are relative to calibration standards and assume a controlled electromagnetic environment per EN : DC Voltage Specifications Maximum Input V on any range Common Mode Rejection db at 50 or 60 Hz ± 0.1 % (1 kω unbalance) Normal Mode Rejection...60 db for NPLC of 1 or greater with dc filter off and power line frequency ±0.1 % 100 db for NPLC of 1 or greater with dc filter on and power line frequency ±0.1 % Measurement Method...Multi-ramp A/D A/D Linearity % of measurement % of range Input Bias Current...<30 pa at 25 C Autozero Off Operation...Following instrument warm-up at calibration temperature ±1 C and less than 10 minutes, add error: % range additional error + 5 μv. Settling Considerations...Measurement settling times are affected by source impedance, cable dielectric characteristics, and input signal changes. Input Characteristics Full Scale (6½ Digits) 4½ Digits 5½ Digits 6½ Digits Input Impedance 100 mv mv 10 µv 1 µv 100 nv 10 MΩ or >10 GΩ [1] 1 V V 100 µv 10 µv 1 µv 10 MΩ or >10 GΩ [1] 10 V V 1 mv 100 µv 10 µv 10 MΩ or >10 GΩ [1] 100 V V 10 mv 1 mv 100 µv 10 MΩ ±1% 1000 V 1, V 100 mv 10 mv 1 mv 10 MΩ ±1% [1] Inputs beyond ±14 V are clamped through 200 kω typical. 10 MΩ is default input impedance. 8846A Accuracy 100 mv V V V V A Accuracy 100 mv V V V V Fluke Corporation 8845A and 8846A

4 Additional Errors Digits NPLC Additional Noise Error 6½ % of range 6½ 10 0 % of range 5½ % of range 5½ % of range + 20 μv 4½ % of range + 20 μv AC Voltage Specifications AC Voltage specifications are for ac sinewave signals >5 % of range. For inputs from 1 % to 5 % of range and <50 khz, add an additional error of 0.1 % of range, and for 50 to 100 khz, add 0.13 % of range. Maximum Input V rms or 1000 V peak (8845A), 1000 V rms or 1414 V peak (8846A) or 8 x 10 7 Volts-Hertz product (whichever is less) for any range. Measurement Method...AC-coupled true-rms. Measures the ac component of input with up to 1000 V dc bias on any range. AC Filter Bandwidth: Slow...3 Hz 300 khz Medium...20 Hz 300 khz Fast Hz 300 khz Common Mode Rejection...70 db at 50 Hz or 60 Hz ±0.1 % (1 kω unbalance) Maximum Crest Factor...5:1 at Full Scale Additional Crest Factor Errors (<100 Hz)...Crest Factor 1-2, 0.05 % of full scale Crest Factor 2-3, 0.2 % of full scale Crest Factor 3-4, 0.4 % of full scale Crest Factor 4-5, 0.5 % of full scale Input Characteristics Full Scale (6½ Digits) 4½ Digits 5½ Digits 6½ Digits 100 mv mv 10 µv 1 µv 100 nv 1 V V 100 µv 10 µv 1 µv 10 V V 1 mv 100 µv 10 µv 100 V V 10 mv 1 mv 100 µv 1000 V 1, V 100 mv 10 mv 1 mv 8846A Accuracy 100 mv 1 V 10 V 100 V 3 5 Hz Hz Hz 20 khz khz khz khz [1] Hz Hz Hz 20 khz khz khz khz [1] Hz Hz Hz 20 khz khz khz khz [1] Hz Hz Hz 20 khz khz khz khz [1] Input Impedance 1 MΩ ±2 % shunted by <100 pf 8845A and 8846A Fluke Corporation 3

5 3 5 Hz Hz Fluke Corporation 8845A and 8846A

6 Resistance Specifications are for 4-wire resistance function, 2 x 4-wire resistance, or 2-wire resistance with zero. If zero is not used, add 0.2 Ω for 2- wire resistance plus lead resistance, and add 20 mω for 2 x 4-wire resistance function. Measurement Method...Current source referenced to LO input. Max. Lead Resistance (4-wire ohms)...10 % of range per lead for 100 Ω, 1 kω ranges. 1 kω per lead on all other ranges. Input Protection V on all ranges. Input Characteristics Full Scale (6½ Digits) 4½ Digits 5½ Digits 6½ Digits Source Current 10 Ω [1] Ω 1 mω 100 μω 10 μω 5 ma 100 Ω Ω 10 mω 1 mω 100 μω 1 ma 1 kω kω 100 mω 10 mω 1 mω 1 ma 10 kω kω 1 Ω 100 mω 10 mω 100 μa 100 kω kω 10 Ω 1 Ω 100 mω 10 μa 1 MΩ MΩ 100 Ω 10 Ω 1 Ω 10 μa 10 MΩ MΩ 1 kω 100 Ω 10 Ω 1 μa 100 MΩ MΩ 10 kω 1 kω 100 Ω 1 μa 10 MΩ 1.0 GΩ [1] GΩ 100 kω 10 kω 1 kω 1 μa 10 MΩ [1] 8846A Only 8846A Accuracy 10 Ω Ω kω kω kω MΩ MΩ MΩ GΩ A Accuracy 100 Ω kω kω kω MΩ MΩ MΩ Additional Ohms Errors Digits NPLC Additional Noise Error 6½ % of range 6½ 10 0 % of range 5½ % of range 5½ % of range ± 20 mω 4½ % of range ± 20 mω 8845A and 8846A Fluke Corporation 5

7 DC Current Input Protection...Tool-accessible 11 A/1000 V and 440 ma/1000 V fuses. Input Characteristics Full Scale Shunt Resistance (6½ Digits) 4½ Digits 5½ Digits 6½ Digits (Ohms) Burden Voltage 100 µa µa 10 na 1 na 100 pa 100Ω < ma ma 100 na 10 na 1 na 100Ω < ma ma 1 μa 100 na 10 na 1 Ω <0.025 V 100 ma ma 10 µa 1 μa 100 na 1 Ω <0.25 V 1 A A 100 µa 10 µa 1 μa 0.01 Ω <0.05 V 3 A [1] A 1 ma 100 µa 10 µa 0.01 Ω <0.15 V 10 A A 1 ma 100 µa 10 µa 0.01 Ω <0.5 V [1] Part of 10 A range. Accuracy (8846A) 100 µa ma ma ma A [2] A [1][2] A [2] [1] Part of 10 A range [2] Available at front panel connectors only Accuracy (8845A) 100 µa ma ma ma A [2] A [1][2] A [2] [1] Part of 10 A range [2] Available at front panel connectors only Additional Current Errors Digits NPLC Additional Noise Error 6½ % of range 6½ 10 0 % of range 5½ % of range 5½ % of range ± 4 μa 4½ % of range ± 4 μa 6 Fluke Corporation 8845A and 8846A

8 AC Current The following ac current specifications are for sinusoidal signals with amplitudes greater than 5 % of range. For inputs from 1% to 5 % of range, add an additional error of 0.1 % of range. Input Protection...Tool accessible 11 A/1000 V and 440 ma/1000 V fuses. Measurement Method...ac-coupled true-rms, dc-coupled to the fuse and shunt (no blocking capacitor) AC Filter Bandwidth Slow...3 Hz to 10 khz Medium...20 Hz to 10 khz Fast Hz to 10 khz Maximum Crest Factor...5:1 at full scale Additional Crest Factor Errors (<100 Hz)...Crest Factor 1-2, 0.05 % of full scale Crest Factor 2-3, 0.2 % of full scale Crest Factor 3-4, 0.4 % of full scale Crest Factor 4-5, 0.5 % of full scale Input Characteristics Full Scale Shunt Resistance (6½ Digits) 4½ Digits 5½ Digits 6½ Digits (Ohms) Burden Voltage 100 μa [1] μa 10 na 1 na 100 pa 100Ω <0.015 V 1 ma [1] ma 100 na 10 na 1 na 100Ω <0.15 V 10 ma ma 1 μa 100 na 10 na 1 Ω <0.025 V 100 ma ma 10 µa 1 μa 100 na 1 Ω <0.25 V 1 A A 100 µa 10 µa 1 μa 0.01 Ω <0.05 V 3 A[2] A 1 ma 100 µa 10 μa 0.01 Ω <0.05 V 10 A A 1 ma 100 µa 10 µa 0.01 Ω <0.5 V [1] 8846A Only [2] Part of 10 A range 8846A Accuracy 100 μa 1 ma 10 ma 100 ma 1 A [2] 3 A [1][2] 10 A [2] (Hz) 3 5 Hz Hz 5 khz khz Hz Hz 5 khz khz Hz Hz 5 khz khz Hz Hz 5 khz khz Hz Hz 5 khz khz Hz Hz Hz 5 khz khz Hz Hz Hz 5 khz khz [1] Part of 10 A range [2] Available only on front panel connectors 8845A and 8846A Fluke Corporation 7

9 8845A Accuracy (Hz) 10 ma 3 5 Hz Hz 5 khz khz ma 3 5 Hz Hz 5 khz khz A [2] 3 5 Hz Hz 5 khz khz A [1][2] 3 5 Hz Hz Hz 5 khz khz A [2] 3 5 Hz Hz Hz 5 khz khz [1] Part of the 10 A range [2] Available only at front panel connectors Additional Low Errors Error is stated as % of reading. AC Filter 3HZ (slow) 20HZ (medium) 200HZ (fast) Hz Hz Hz Hz Hz 1 khz > 1 khz Gate Times...Programmable to 1 s, 100 ms, and 10 ms. Measurement Method...Flexible counting technique. AC-coupled input using the ac voltage measurement function. Settling Considerations...When measuring frequency or period after a dc offset voltage change, errors may occur. For the most accurate measurement, wait up to 1 second for the input blocking capacitor to settle. Measurement Considerations...To minimize measurement errors, shield inputs from external noise when measuring lowvoltage, low-frequency signals. 8846A Accuracy Accuracy is given as ± % measurement 100 mv to 1000 V [1][2] 3 5 Hz Hz Hz Hz 300 khz khz 1 MHz [1] Input >100 mv. For mv, multiply percent measurement error by 10. [2] Limited to 8 X 10 7 volt-hertz 8 Fluke Corporation 8845A and 8846A

10 8845A Accuracy Accuracy is given as ± % measurement 100 mv to 750 V [1][2] 3 5 Hz Hz Hz Hz 300 khz Compensation/ C [1] Input >100 mv. For mv, multiply percent measurement error by 10. [2] Limited to 8 X 10 7 volt-hertz Gate Time vs. Gate Time ½ 0.1 6½ 1.0 6½ Additional Low Errors Error stated as percent of measurement for inputs >100 mv. For mv, multiply percent by 10. 6½ 5½ 4½ 3 5 Hz Hz Hz Hz Hz Hz 1 khz > 1 khz Capacitance (8846A Only) Accuracy is stated as ±(% of measurement + % of range) Accuracy [1] 1 nf 1 pf 2% ± 2.5 % nf 10 pf 1% ± 0.5 % nf 100 pf 1% ± 0.5 % µf 1 nf 1% ± 0.5 % µf 10 nf 1% ± 0.5 % µf 100 nf 1% ± 0.5 % mf 1 µf 1% ± 0.5 % mf 10 µf 1% ± 0.5 % mf 100 µf 4% ± 0.2 % [1] Stated accuracy is attained when Zero function is used. (8846A only) Test Current...1 ma Accuracy is stated as ± C and is based on a Platinum RT100 (DIN IEC 751, 385 type) RTD with less than 10 ohms lead resistance. Specifications do not include probe accuracy, which must be added. Accuracy -200 C C C C C C C C C C C C A and 8846A Fluke Corporation 9

11 Continuity Continuity Threshold...Selectable between 1 Ω and 1000 Ω Test Current...1 ma Response Time samples/sec with audible tone Accuracy is given as ± (% measurements + % of range) Ω Diode Test Test Current μa or 1 ma Response Time samples/sec with audible tone. Accuracy is given as ± (% measurements + % of range) V V Measurement Rates Function Digits Setting Integration Time Measurements/Second [1] 60 Hz (50 Hz) 8845A 8846A DC Volts, DC Current, and 6½ 100 NPLC 1.67 (2) s 0.6 (0.5) 0.6 (0.5) Resistance 6½ 10 NPLC 167 (200) ms 6 (5) 6 (5) 5½ 10 NPLC 16.7 (20) ms 60 (50) 60 (50) 5½ 0.2 NPLC 3 ms AC Voltage and AC Current [2] 6½ 3 Hz ½ 20 Hz 1 1 6½ 200 Hz [3] ½ 200 Hz [4] 6 6 and Period 6½ 1 s 1 1 5½ 100 ms ½ 10 ms [1] Typical measurement rates with autozero off. [2] Maximum measurement rates for 0.01 % of ac step. When dc input varies, additional settling delay is required. [3] For remote operation or external trigger using default settling delay [4] Settling delay = 0 10 Fluke Corporation 8845A and 8846A

12 Fluke. Keeping your world up and running. Fluke Corporation PO Box 9090, Everett, WA USA Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) or Fax (425) In Europe/M-East/Africa +31 (0) or Fax +31 (0) In Canada (800)-36-FLUKE or Fax (905) From other countries +1 (425) or Fax +1 (425) Web access: Fluke Corporation. All rights reserved. Printed in U.S.A. 8/ D-EN-N Rev A Pub_ID: eng Rev 01

8845A/8846A 6.5 Digit Precision Multimeters

8845A/8846A 6.5 Digit Precision Multimeters 8845A/8846A 6.5 Digit Precision Multimeters Precision and versatility for bench or systems applications Fluke 8845A The Fluke 8845A and 8846A, 6.5 digit precision multimeters have the precision and versatility

More information

Fluke 8808A Digital Multimeter Extended Specifications

Fluke 8808A Digital Multimeter Extended Specifications Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Fluke 8808A Digital Multimeter Extended Specifications Making measurements is as simple as pushing a

More information

Datasheet. SDM3065X Digital Multimeter. Product Overview. Main Feature. Application fields. Main Function

Datasheet. SDM3065X Digital Multimeter. Product Overview. Main Feature. Application fields. Main Function Datasheet SDM3065X Digital Multimeter Product Overview SDM3065X is a 6 ½ digit digital (2,200,000 count) multimeter incorporating a dual display and is especially well suited for the needs of high-precision,

More information

8845A/8846A. Calibration Manual. Digital Multimeter

8845A/8846A. Calibration Manual. Digital Multimeter 8845A/8846A Digital Multimeter Calibration Manual January 2007 2007 Fluke Corporation, All rights reserved. All product names are trademarks of their respective companies. LIMITED WARRANTY AND LIMITATION

More information

5520A. Multi-Product Calibrator. Extended Specifications 2005

5520A. Multi-Product Calibrator. Extended Specifications 2005 5520A Multi-Product Calibrator Extended Specifications 2005 5520A Specifications The following tables list the 5520A specifications. All specifications are valid after allowing a warm-up period of 30 minutes,

More information

5520A. Multi-Product Calibrator. Extended Specifications

5520A. Multi-Product Calibrator. Extended Specifications 5520A Multi-Product Calibrator Extended Specifications Specifications The following tables list the 5520A specifications. All specifications are valid after allowing a warm-up period of 30 minutes, or

More information

True RMS Bench Multimeter 5492B

True RMS Bench Multimeter 5492B Data Sheet True RMS Bench Multimeter 5492B True RMS Bench Multimeter The B&K Precision model 5492B is a versatile 5½-digit, 120,000-count bench multimeter suitable for applications in education, service

More information

5080A Multi-Product Calibrator

5080A Multi-Product Calibrator 5080A Multi-Product Calibrator Calibration solutions for your analog and digital workload 5080A Multi-Product Calibrator: expanded workload coverage Calibrate analog and digital meters, and much more The

More information

RIGOL Data Sheet DM3058/DM3058E Digital Multimeter Product Overview Applications Easy to Use Design Main Features owerful Measurement Functions

RIGOL Data Sheet DM3058/DM3058E Digital Multimeter Product Overview Applications Easy to Use Design Main Features owerful Measurement Functions RIGOL Data Sheet Product Overview DM3058/DM3058E [1] is a digital multimeter designed with 5 ½ digits readings resolution and dual-display especially fitting to the needs of high-precision, multifunction

More information

Keysight 34401A Multimeter

Keysight 34401A Multimeter Keysight 34401A Multimeter Data Sheet See Keysight's Truevolt Series of DMMs You also get both GPIB and RS-232 interfaces as standard features. Voltmeter Complete and External Trigger signals are provided

More information

Fluke 1587 FC/1577 Insulation Multimeters

Fluke 1587 FC/1577 Insulation Multimeters TECHNICAL DATA Fluke 587 FC/577 Insulation Multimeters The High-Performance 2-in- Insulation DMM The Fluke 587 FC and 577 Insulation Multimeters combine a digital insulation tester with a full-featured,

More information

True RMS Bench Multimeters 2831E and 5491B

True RMS Bench Multimeters 2831E and 5491B Data Sheet True RMS Bench Multimeters and True RMS Bench Multimeters with Dual Display The B&K Precision models and are versatile and dependable bench multimeters suitable for applications in education,

More information

Model ½-Digit Multimeter Datasheet

Model ½-Digit Multimeter Datasheet Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Model 2000 6½-Digit Multimeter Datasheet Ordering Information 2000 6½-Digit DMM 2000/2000-SCAN 6½-Digit

More information

Digital Multimeters. Tektronix DMM4020 Data Sheet. Features & Benefits. Available Functions and Features. Connectivity. Key Performance Specifications

Digital Multimeters. Tektronix DMM4020 Data Sheet. Features & Benefits. Available Functions and Features. Connectivity. Key Performance Specifications Digital Multimeters Tektronix DMM4020 Data Sheet Available Functions and Features Volts, Ohms, and Amps Measurements True RMS (AC, AC + DC) Measurements Diode and Continuity Testing Frequency Measurements

More information

Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size

Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size Data Sheet Features 1-Slot, C-size, message-based DCV, ACV, DCI, ACI, 2/4-wire Ω, frequency, period NULL, MIN/MAX, LIMIT, db, dbm 1000 reading/s

More information

1507/1503. Insulation Testers. Technical Data. Features and benefits:

1507/1503. Insulation Testers. Technical Data. Features and benefits: 1507/1503 Insulation Testers Technical Data The Fluke 1507 and 1503 Insulation Testers are compact, rugged, reliable, and easy to use. With their multiple test voltages, they are ideal for many troubleshooting,

More information

Agilent 34405A Multimeter

Agilent 34405A Multimeter 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price Data Sheet Features 120000

More information

5522A Multi-Product Calibrator Extended specifications

5522A Multi-Product Calibrator Extended specifications 5522A Multi-Product Calibrator Extended specifications General Specifications The following tables list the 5522A specifications. All specifications are valid after allowing a warm-up period of 30 minutes,

More information

SDM3055 Digital Multimeter. DataSheet

SDM3055 Digital Multimeter. DataSheet SDM3055 Digital Multimeter DataSheet-2017.06 SDM3055 Product Overview The SDM3055 is a digital multimeter designed with 5 ½ digits readings resolution and dual-display, especially fitting to the needs

More information

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications These specifications apply to the 5520A-SC1100, 5500A-SC600 and 5500A-SC300 Oscilloscope Calibration

More information

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications November 1999 General Specifications These specifications apply to the 5520A-SC1100, 5500A-SC600

More information

Keysight Technologies 34450A Multimeter 5.5 Digit Dual Display, Benchtop DMM. Data Sheet

Keysight Technologies 34450A Multimeter 5.5 Digit Dual Display, Benchtop DMM. Data Sheet Keysight Technologies 34450A Multimeter 5.5 Digit Dual Display, Benchtop DMM Data Sheet 02 Keysight 34450A Multimeter 5.5 Digit Dual Display, Benchtop DMM Data Sheet Features Fast reading speed of up to

More information

Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators

Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators Extended Specifications These specifications apply to the 5520A-SC1100, 5500A- SC600 and 5500A-SC300 Oscilloscope Calibration

More information

6 1 2-Digit Digital Multimeter, 1.8 MS/s Isolated Digitizer, and LCR Meter

6 1 2-Digit Digital Multimeter, 1.8 MS/s Isolated Digitizer, and LCR Meter NI PXI-4072 FlexDMM Superior accuracy and measurement rates Multifunction device 6 1 2-digit digital multimeter 1.8 MS/s isolated digitizer LCR meter (inductance, capacitance, and resistance) 20 built-in

More information

Fluke Norma 4000/5000

Fluke Norma 4000/5000 Fluke Norma 4000/5000 High Precision Power Analyzers Reliable, highly accurate measurements for the test & development of power electronics Technical Data Compact Fluke Norma Series power analyzers include

More information

Fluke 2638A/05 Hydra Series III 22-Channel Data Acquisition System

Fluke 2638A/05 Hydra Series III 22-Channel Data Acquisition System Fluke 2638A/05 Hydra Series III 22-Channel Data Acquisition System Technical Data Price-performance breakthrough in a stand-alone data acquisition system The Fluke 2638A/05 Hydra Series III continues the

More information

Agilent U3400 Series 4½ and 5½ Digit Digital Multimeters

Agilent U3400 Series 4½ and 5½ Digit Digital Multimeters Agilent U3400 Series 4½ and 5½ Digit Digital Multimeters Data Sheet Basic + Good = Elegant Simplicity Features Up to 120,000 counts resolution Up to 0.012% basic DCV accuracy 11 basic measurements and

More information

Racal Instruments. Product Information

Racal Instruments. Product Information Racal Instruments 6084A-104-DMM 1 GHz Digitizer and 7.5 Digit Digital Multimeter The Digitizer/DMM increases test system performance and density by packaging a 7.5 digit Digital Multimeter (DMM) together

More information

79/26 Series III Multimeter

79/26 Series III Multimeter 79/26 Series III Multimeter Instruction Sheet W Read First: Safety Information Never use the meter if the meter or test leads look damaged. Be sure the test leads and switch are in the correct position

More information

SPECIFICATIONS FOR THE NI PXI/PCI-4060

SPECIFICATIONS FOR THE NI PXI/PCI-4060 SPECIFICATIONS FOR THE NI PXI/PCI-4060 This document lists the specifications of the NI PXI/PCI-4060. These specifications are guaranteed between 15 and 35 C unless otherwise specified. DC Voltage (% of

More information

Chapter 5 Specifications

Chapter 5 Specifications RIGOL Specifications are valid under the following conditions: the instrument is within the calibration period, is stored for at least two hours at 0 to 50 temperature and is warmed up for 40 minutes.

More information

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals The Fluke 6100A Electrical Power Standard The most accurate, comprehensive and flexible source of electrical power signals Measurement validation for electrical power applications The importance of accurate

More information

Service Guide RIGOL. DM3000 Series Digital Multimeter DM3061/2/4 DM3051/2/4. Publication number: SGC Dec. 2008

Service Guide RIGOL. DM3000 Series Digital Multimeter DM3061/2/4 DM3051/2/4. Publication number: SGC Dec. 2008 Service Guide RIGOL Publication number: SGC01108-1210 Dec. 2008 DM3000 Series Digital Multimeter DM3061/2/4 DM3051/2/4 2008 RIGOL Technologies, Inc. All Rights Reserved Copyright Information 2008 RIGOL

More information

Specifications. 744 Users Manual

Specifications. 744 Users Manual 80T-150U Temperature Probe 80PK series thermocouples 80i-410 Clamp-on DC/AC Current Probe 80i-1010 Clamp-on DC/AC Current Probe 80i-500s Clamp-on AC Current Probe (requires the Y9108 adapter) 80i-1000s

More information

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals The Fluke 6100A Electrical Power Standard The most accurate, comprehensive and flexible source of electrical power signals Measurement validation and calibration for electrical power applications The importance

More information

5320A Multifunction Electrical Tester Calibrator. Verify and calibrate electrical test tools with a single instrument

5320A Multifunction Electrical Tester Calibrator. Verify and calibrate electrical test tools with a single instrument 5320A Multifunction Electrical Tester Calibrator Verify and calibrate electrical test tools with a single instrument 5320A Multifunction Electrical Tester Calibrator: Wide workload coverage with a single

More information

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality

More information

Fluke Norma 4000/5000

Fluke Norma 4000/5000 Fluke Norma 4000/5000 High Precision Power Analyzers Reliable, highly accurate measurements for the test & development of power electronics Technical Data Compact Fluke Norma Series power analyzers include

More information

PXI Contents SPECIFICATIONS. 6½-Digit, ±300 V, Onboard 1.8 MS/s Isolated Digitizer, L and C Measurement Support, PXI Digital Multimeter

PXI Contents SPECIFICATIONS. 6½-Digit, ±300 V, Onboard 1.8 MS/s Isolated Digitizer, L and C Measurement Support, PXI Digital Multimeter SPECIFICATIONS PXI-4072 6½-Digit, ±300 V, Onboard 1.8 MS/s Isolated Digitizer, L and C Measurement Support, PXI Digital Multimeter These specifications apply to the PXI-4072. Contents Definitions...2 Conditions...

More information

7461A/7451A Digital Multimeter High-speed and variable integration time DMM supporting multiple applications

7461A/7451A Digital Multimeter High-speed and variable integration time DMM supporting multiple applications / Digital Multimeter High-speed and variable integration time DMM supporting multiple applications l Two models by use 6½-digit () 5½-digit () l Fast sampling : 20,000 readings/sec () 5,000 readings/sec

More information

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution

More information

Agilent U1450A/U1460A Insulation Resistance Testers

Agilent U1450A/U1460A Insulation Resistance Testers Agilent U1450A/U1460A Insulation Resistance Testers Data Sheet Accomplish more in a day s work with the Agilent U1450A/U1460A series insulation resistance testers. With a single tool, get remote testing

More information

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters TECHNICAL DATA Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters The new Fluke 370 FC Series (376 FC, 375 FC and 374 FC) offers advanced troubleshooting performance. The iflex flexible current allows

More information

SOLICITUD XXVI CONGRESO NACIONAL DE METROLOGIA

SOLICITUD XXVI CONGRESO NACIONAL DE METROLOGIA SOLICITUD XXVI CONGRESO NACIONAL DE METROLOGIA Técnicas para la calibración de medidores analógicos Bill Gaviria Regional Product Manager Direct: +1.425.446.5335 Cell: +1.321.626.7845 Email: bill.gaviria@flukecal.com

More information

Agilent U1230 Series Handheld Digital Multimeter (DMM)

Agilent U1230 Series Handheld Digital Multimeter (DMM) Agilent U1230 Series Handheld Digital Multimeter (DMM) Data Sheet Whether it is dark, noisy or even dangerous, the U1230 Series handheld digital multimeter keeps you equipped with features that anticipate

More information

PCI Express, 6½-Digit, ±300 V Digital Multimeter Device

PCI Express, 6½-Digit, ±300 V Digital Multimeter Device SPECIFICATIONS PCIe-4065 PCI Express, 6½-Digit, ±300 V Digital Multimeter Device These specifications apply to the PCIe-4065. Contents Definitions...1 Conditions... 2 DC Specifications... 2 DC System Speed

More information

Keysight Technologies PXI Digital Multimeters 6½ Digit, High Performance (M9182A, M9183A)

Keysight Technologies PXI Digital Multimeters 6½ Digit, High Performance (M9182A, M9183A) Keysight Technologies PXI Digital Multimeters 6½ Digit, High Performance (M9182A, M9183A) Data Sheet 6½ digit resolution High throughput: up to 15,000 rdgs/sec, 66 µs single reading interval DCV basic

More information

DM-45 Digital Multimeter

DM-45 Digital Multimeter INSTRUCTION MANUAL DM-45 Digital Multimeter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Description The Greenlee DM-45 Digital

More information

PM 6669 High-Precision Frequency Counter Specifications

PM 6669 High-Precision Frequency Counter Specifications PM 6669 High-Precision Frequency Counter Specifications Product Home Features Specifications Models, Options & Accessories Measuring functions Definitions Input specifications Auxiliary functions TimeBase

More information

System SourceMeter SMU Instruments

System SourceMeter SMU Instruments Series 600B Tightly integrated, 4-quadrant voltage/current source and measure instruments offer best in class performance with 6½-digit resolution Family of models offer industry s widest dynamic range:

More information

# Digital Multimeter

# Digital Multimeter #61-797 Digital Multimeter - 1 - TABLE OF CONTENTS 1.Introduction Precautions and Safety Information Symbols Safety 2.Specifications General Specifications Electrical Specifications Required Equipment

More information

Electrical Multimeter

Electrical Multimeter 113 Electrical Multimeter Instruction Sheet Safety Information A Warning statement identifies hazardous conditions and actions that could cause bodily harm or death. A Caution statement identifies conditions

More information

Nanovoltmeter 2182A. Low noise measurements for research, metrology, Side Text and other low voltage testing applications LOW LEVEL MEASURE & SOURCE

Nanovoltmeter 2182A. Low noise measurements for research, metrology, Side Text and other low voltage testing applications LOW LEVEL MEASURE & SOURCE Make low noise measurements at high speeds, typically just 15nV p-p noise at 1s response time, 40 50nV p-p noise at 60ms Delta mode coordinates measurements with a reversing current source at up to 24Hz

More information

2790 SourceMeter Airbag Test System

2790 SourceMeter Airbag Test System 2790 Meter Airbag Test System Single-instrument solution for continuity and hi-pot type leakage resistance measurements Programmable constant V source (50 500V) supports high speed, high resistance measurements

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at ProcessMeter.

99 Washington Street Melrose, MA Phone Toll Free Visit us at  ProcessMeter. 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 789 ProcessMeter Users Manual LIMITED WARRANTY AND LIMITATION OF LIABILITY This

More information

Handheld Digital Storage Oscilloscopes 2510 Series

Handheld Digital Storage Oscilloscopes 2510 Series Data Sheet Handheld Digital Storage Oscilloscopes The handheld digital storage oscilloscopes provide floating measurement and recorder capabilities with a built-in digital multimeter (DMM), all in one

More information

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph ENGLISH Datasheet Stock No. 123-3249 RS PRO IDM 99III Digital Multimeter Feature: 6000 count digital display with 62 segment bar graph Extra Large scale display and white backlit AC+DC True RMS 0.08% basic

More information

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

Dual Channel Function/Arbitrary Waveform Generators 4050B Series Data Sheet Dual Channel Function/Arbitrary Waveform Generators The Dual Channel Function/ Arbitrary Waveform Generators are capable of generating stable and precise sine, square, triangle, pulse, and arbitrary

More information

Maintain power systems, troubleshoot power problems, diagnose equipment failures

Maintain power systems, troubleshoot power problems, diagnose equipment failures Fluke 43B Quality Analyzer Maintain power systems, troubleshoot power problems, diagnose equipment failures 1 2 43B POWER QUALITY ANALYZER The Fluke 43 Quality Analyzer performs the measurements you need

More information

System SourceMeter SMU Instruments

System SourceMeter SMU Instruments Test Equipment Depot - 800.517.841-99 Washington Street Melrose, MA 0176 - TestEquipmentDepot.com Series 600B Tightly integrated, 4-quadrant voltage/current source and measure instruments offer best in

More information

6½-Digit, ±300 V, 1.8 MS/s Isolated Digitizer Included, PCI Digital Multimeter Device

6½-Digit, ±300 V, 1.8 MS/s Isolated Digitizer Included, PCI Digital Multimeter Device SPECIFICATIONS PCI-4070 6½-Digit, ±300 V, 1.8 MS/s Isolated Digitizer Included, PCI Digital Multimeter Device These specifications apply to the PCI-4070. Contents Definitions...2 Conditions... 2 DC Specifications...

More information

Multifunction Calibrator - Model 8080

Multifunction Calibrator - Model 8080 .. Multifunction Calibrator - Model 8080 Current Calibrator to 20 A Voltage Calibrator to 1000 V Power Calibrator to 2400 W Exceptional Uncertainties Extremely User Friendly NIST Traceable Description

More information

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement Data Sheet Analog Digital Multimeter with Insulation resistance www.rishabh.co.in Page 1 of 6 Version: J 28/12/2011 Application

More information

Fluke 1750 Three-Phase Power Recorder

Fluke 1750 Three-Phase Power Recorder TECHNICAL DATA Fluke 1750 Three-Phase Power Recorder Never miss capturing a disturbance with the exclusive threshold-free measurement system, it s automatic. Capture every measurement, every event, on

More information

Maximizing your reference multimeter, minimizing measurement uncertainties

Maximizing your reference multimeter, minimizing measurement uncertainties Maximizing your reference multimeter, minimizing measurement uncertainties Introduction Modern precision digital multimeters are sophisticated measuring instruments offering more than just the ability

More information

Laboratory for Fundamentals of Electrical Engineering (Labor Grundlagen der Elektrotechnik) Equipment Manuals for use in laboratory for measurement

Laboratory for Fundamentals of Electrical Engineering (Labor Grundlagen der Elektrotechnik) Equipment Manuals for use in laboratory for measurement Laboratory for Fundamentals of Electrical Engineering (Labor Grundlagen der Elektrotechnik) Equipment Manuals for use in laboratory for measurement Gossen, Metrawatt, Camille Bauer METRAHit 15S System

More information

Loop calibration and maintenance

Loop calibration and maintenance Loop calibration and maintenance pplication Note Introduction Process instrumentation requires periodic calibration and maintenance to ensure that it is operating correctly. This application note contains

More information

PXIe, 6½-Digit, ±300 V, Onboard 1.8 MS/s Isolated Digitizer,PXI Digital Multimeter

PXIe, 6½-Digit, ±300 V, Onboard 1.8 MS/s Isolated Digitizer,PXI Digital Multimeter SPECIFICATIONS PXIe-4080 PXIe, 6½-Digit, ±300 V, Onboard 1.8 MS/s Isolated Digitizer,PXI Digital Multimeter These specifications apply to the PXIe-4080. Contents Definitions...2 Conditions... 2 DC Voltage

More information

Arbitrary/Function Generator AFG1000 Series Datasheet

Arbitrary/Function Generator AFG1000 Series Datasheet Arbitrary/Function Generator AFG1000 Series Datasheet 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Compatible with TekSmartLab

More information

U1604A Handheld Oscilloscopes, 40 MHz

U1604A Handheld Oscilloscopes, 40 MHz Products & Services Technical Support Buy Industries About Agilent Search: All Test & Measurement Go United States Home >... > Oscilloscopes > U1600A Series handheld oscilloscopes (2 models) > U1604A Handheld

More information

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual DUAL DISPLAY DIGITAL MULTIMETER User s Manual MS8250D 1. Safety Information Warning Use caution and follow all safety guidelines to prevent electric shock or damage to the meter. Please ready carefully

More information

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits ISOBE5600 Isolated Probe Systems - ISOBE5600 Isolation system - ISOBE5600 Transient recorder Data sheet Features and Benefits ISOBE5600 Isolation system - Cost-effective - Fiber-optic isolation - Analogue-in

More information

Appendix A: Specifications

Appendix A: Specifications All specifications apply to the TDS 200-Series Digital Oscilloscopes and a P2100 probe with the Attenuation switch set to 10X unless noted otherwise. To meet specifications, two conditions must first be

More information

1594A/1595A Super-Thermometers. Recognized worldwide for ease of use and reliable accuracy

1594A/1595A Super-Thermometers. Recognized worldwide for ease of use and reliable accuracy 1594A/1595A Super-Thermometers Recognized worldwide for ease of use and reliable accuracy A unique combination of performance and value The Fluke Calibration 1594A and 1595A Super-Thermometers combine

More information

Pinpoint power quality problems faster

Pinpoint power quality problems faster Pinpoint power quality problems faster Fluke 430 Series three-phase and Fluke 43B single-phase Power Quality Analyzers Analyze your power network quickly Measure all power parameters, find events and anomalies

More information

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO AMPROBE 1 Congratulations! You are now the owner of an AMPROBE Instrument. It has been quality crafted according to quality standards and contains quality components

More information

8808A. Users Manual. Digital Multimeter

8808A. Users Manual. Digital Multimeter 8808A Digital Multimeter Users Manual July 2007 2007 Fluke Corporation, All rights reserved. All product names are trademarks of their respective companies. LIMITED WARRANTY AND LIMITATION OF LIABILITY

More information

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Dual Channel Function/Arbitrary Waveform Generators 4050 Series Data Sheet Dual Channel Function/Arbitrary Waveform Generators The Dual Channel Function/Arbitrary Waveform Generators are capable of generating stable and precise sine, square, triangle, pulse, and arbitrary

More information

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs With compliments All specifications apply to the TDS 200-Series Digital Real-Time Oscilloscope with a P2100 probe with the Attenuation switch set to 10X unless noted otherwise. To meet specifications,

More information

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator Page 1 of 7 Arbitrary Waveform Generator AWG 2040 This product is no longer carried in our catalog. Features 1.024 GS/sec Clock Rate Provides up to 500 MHz Waveforms 1 MB Record Length (4 MB with Opt.

More information

Arbitrary/Function Waveform Generators 4075B Series

Arbitrary/Function Waveform Generators 4075B Series Data Sheet Arbitrary/Function Waveform Generators Point-by-Point Signal Integrity The Arbitrary/Function Waveform Generators are versatile high-performance single- and dual-channel arbitrary waveform generators

More information

SourceMeter Line. Series Tightly coupled precision sourcing and measurement KEITHLEY (U.S. only) SOURCE AND MEASURE

SourceMeter Line. Series Tightly coupled precision sourcing and measurement KEITHLEY (U.S. only)  SOURCE AND MEASURE Line Tightly coupled precision sourcing and measurement Family of products offers wide dynamic range: 10pA to 10A, 1µV to 1100V, 20W to 1000W 4-quadrant operation 0.012% basic accuracy with 5 1 2-digit

More information

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc. SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter Datasheet 2017 SignalCore, Inc. support@signalcore.com P RODUCT S PECIFICATIONS Definition of Terms The following terms are used throughout this datasheet

More information

Keysight 34970A Data Acquisition/Switch Unit

Keysight 34970A Data Acquisition/Switch Unit Keysight 34970A Data Acquisition/Switch Unit Service Guide Copyright Keysight Technologies, 1997-2015 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

183 & 185. True RMS Multimeters. Users Manual. February 2001 Rev.2, 4/02

183 & 185. True RMS Multimeters. Users Manual. February 2001 Rev.2, 4/02 183 & 185 True RMS Multimeters February 2001 Rev.2, 4/02 2001-2002 Fluke Corporation. All rights reserved. Printed in USA All product names are trademarks of their respective companies. LIFETIME LIMITED

More information

Current Clamp. 210

Current Clamp. 210 Our range of devices includes clamp meters for measuring current leaks, AC and DC current, voltage, power, resistance, continuity, capacitance or frequency. Some clamp meters have a clearly arranged display

More information

50000 Counts Dual Display Digital Multimeter

50000 Counts Dual Display Digital Multimeter 50000 Counts Dual Display Digital Multimeter GDM-8245 (50000 Counts) The GDM-8245 is an economical bench-top DMM equipped with a rich set of features. The GDM-8245 has similar functions to the GDM-8246,

More information

SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module. Datasheet SignalCore, Inc.

SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module. Datasheet SignalCore, Inc. SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module Datasheet 2015 SignalCore, Inc. support@signalcore.com SC5306B S PECIFICATIONS Definition of Terms The following terms are used throughout this datasheet

More information

General Specifications

General Specifications General Specifications Model CA51/ CA71 HANDY CAL calibrator GS 77W02A01-01-E GENERAL The CA51/CA71 HANDY CAL calibrators are comprehensive generating/measuring instruments for all

More information

Output Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources.

Output Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources. 3 Channel Digital Storage Oscilloscope (DSO) Instrument VERTICAL SPECIFICATIONS Analogue Bandwidth (-3dB) Bandwidth Limiting Rise time (10% to 90%, calculated) Input ranges (full scale) Input sensitivity

More information

R&S ZNC Vector Network Analyzer Specifications

R&S ZNC Vector Network Analyzer Specifications ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement

More information

RIGOL Service Guide. DM3058 Digital Multimeter. Jan RIGOL Technologies, Inc.

RIGOL Service Guide. DM3058 Digital Multimeter. Jan RIGOL Technologies, Inc. Service Guide DM3058 Digital Multimeter Jan. 2009 RIGOL Technologies, Inc. Copyright 2008 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is registered trademark of RIGOL Technologies,

More information

Dimensional Up to 25 mm/ mm 2.0 µm 0 mm to 100 mm/ 0.01 mm 7.4 μm 100 mm to 300 mm/ 0.01 mm 10 μm

Dimensional Up to 25 mm/ mm 2.0 µm 0 mm to 100 mm/ 0.01 mm 7.4 μm 100 mm to 300 mm/ 0.01 mm 10 μm IAS Accreditation Number Company Name CL-154 Almeer Technical Services Calibration Laboratory Address Plot No. 100/104, Area 7 P.O. Box 9240 Ahmadi, 61003 Kuwait Contact Name Satyananda Rao, Technical

More information

Standard Resistors Precision DC Shunts Digital Thermometers Non-inductive AC Shunts Intelligent Teraohmmeter Precision Decade Standards Precision Air

Standard Resistors Precision DC Shunts Digital Thermometers Non-inductive AC Shunts Intelligent Teraohmmeter Precision Decade Standards Precision Air Standard Resistors Precision DC Shunts Digital Thermometers Non-inductive AC Shunts Intelligent Teraohmmeter Precision Decade Standards Precision Air Temperature Baths Precision Oil Temperature Baths Ultra-High

More information

PXIe Contents. Required Software CALIBRATION PROCEDURE

PXIe Contents. Required Software CALIBRATION PROCEDURE CALIBRATION PROCEDURE PXIe-5160 This document contains the verification and adjustment procedures for the PXIe-5160. Refer to ni.com/calibration for more information about calibration solutions. Contents

More information

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series USER'S MANUAL ACD-6 Pro ACD-6 TRMS Pro Versatile Clamp-on Multimeter Series 1 1) SAFETY This manual contains information and warnings that must be followed for operating the instrument safely and maintaining

More information

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

USB-TEMP and TC Series USB-Based Temperature Measurement Devices USB-Based Temperature Measurement Devices Features Temperature and voltage measurement USB devices Thermocouple, RTD, thermistor, or semiconductor sensor measurements Eight analog inputs Up to ±10 V inputs*

More information

Calibration Department Address Yard No 304 Road 4306 Block 343 Mina Salman Industrial Area Manama, Bahrain. 0 mm to 600 mm / 0.01 mm 7.

Calibration Department Address Yard No 304 Road 4306 Block 343 Mina Salman Industrial Area Manama, Bahrain. 0 mm to 600 mm / 0.01 mm 7. IAS Accreditation Number CL-132 Accredited Entity Address Yard No 304 Road 4306 Block 343 Mina Salman Industrial Area Manama, Bahrain Contact Name Mr. Masood Khatib Mr. Raja Kalimuthu Telephone +973 17727450

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Wilmington Instrument Company, Inc. 332 North

More information

ARCO 400. Technical Data

ARCO 400. Technical Data Technical Data OMICRON electronics GmbH 2017. All rights reserved. This technical data was extracted from the following manual: ENU 1119 04 03 All rights including translation reserved. Reproduction of

More information