Economic Separations. Product Catalog.
|
|
- Ralph Mason
- 5 years ago
- Views:
Transcription
1 Economic Separations Horizontal Electrophoresis Apparatus Vertical Electrophoresis Apparatus Electroblotting Apparatus UV-Transilluminators Gel-Documentation Power Packs Product Catalog
2 EcoSep product overview 1. TechResource manufactures and markets products under the brand name and we issue a Manufacturing Certificate to facilitate purchasing formalities. 2. We offer a One-Year Warranty against manufacturing defects and such repairs will be done free of cost during the warranty period. The product can be shipped to TechResource office in Mumbai where it will be attended to and returned to the user. 3. s marked Ready-to-use include all essential components required to use the apparatus (Power supply not included). Spares and accessories are also available with us. 4. Do not use chemicals that adversely react with acrylic (PMMA). 5. Please visit the website or for further details. 6. Enquiries may be sent to ecosep@vsnl.net. 7. Design and specifications of the apparatus can be changed from time to time to reflect improvements in design, manufacturing methods and the economical availability of inputs. ORDERING INFORMATION, PAYMENT and SHIPPING TERMS 1. Make sure catalog numbers for ordered items are correct. 2. Prices are subject to change without notice. 3. Prices are for ex-sellers place. Freight is charged on actuals or on a TO-PAY basis. Products are shipped via a reliable courier service by surface transport. 4. Taxes & Levies applicable at the time of dispatch will be borne by the Client. a. Present 12.5% b. Order accompanied by C / D form Present 2%. c. Octroi/LBT as per local rates. 5. Quotations are valid for a period of 90 days % Payment ON DELIVERY by Demand Draft, NEFT, or by crossed Account Payee cheque drawn on any nationalized bank in favor of TECHRESOURCE and payable at par at Mumbai % per annum will be charged if payments are not received as per stipulated Terms of Payment. 8. Exemptions of taxes and levies can be availed ONLY if valid forms are submitted along with the order. 9. Products will be shipped only after receipt of the relevant shipping permits. DISCLAIMER 1. TechResource is not bound to provide live demonstrations and installations. 2. To and fro transportation cost for repairs is to be borne by the client when warranty is not applicable. 3. EcoSep products are designed and made for educational purposes and are to be used for the same. TechResource will accept no liabilities arising out of product misuse or abuse. TechResource, 188 Nagdevi Street, 2 nd Floor, Mumbai Website: ecosep@vsnl.net Tel: (022)
3 C ONTENTS EcoSep product overview 1 Vertical electrophoresis apparatus Features and selection guide 3 Slimpage Gel size 4 (w) x 8.5 (l) cm 4 Ecopage Gel size 7 (w) x 8.5 (l) cm 4 Electroblotting apparatus Features 5 Nanoblot Gel size 6 (w) x 5 (l) cm 5 Horizontal electrophoresis apparatus Features and selection guide 6 Slimsub Gel size 3 (w) x 10 (l) cm 7 Ecosub Gel size 7 (w) x 10 (l) cm 7 Tubbysub Gel size 15(w) x 10 (l) cm 8 UV transilluminators Features 9 Gloworm-2 2 UVA tubes 9 Gloworm-4 4 UVA tubes 9 Gel documentation system EcoDoc 10 Power supply unit Electravolt Range 80 V, 110 V, 140 V, 170 V, 200 V 10 EcoSep Labware Stand for micropipettes 11 Holder for micro test-tube with cap-opener 11 Tip and tube discard container 11 Microbial chemotaxis chamber 11 Accessories for electrophoresis apparatus Gel-sandwich opener 11 Agarose dispenser 11 Gel slicer 12 Electrical cords 12 Gradient mixer 12 Leveling table 12 List of equipment, spares and accessories 13 General information on electrophoresis 14 Tables
4 VERTICAL ELECTROPHORESIS APPARATUS FEATURES ECONOMICAL Less buffer required by virtue of its compact design For faster separations the apparatus can be conveniently placed in the refrigerator due to its small footprint Saves reagent & operator cost as leakage & errors are prevented RUGGED Durable PMMA combs, spacers & thick glass plates No electrolytic corrosion of male connector as base is resin filled Electrodes do not break or pit as they are protected and the platinum is >99.9% pure LEAK-PROOF No leakage of upper tank buffer as silicone gasket is tough & resilient No leakage from plastic joints as bonding is done with special glues Leak-proof sealing with agar in lower tank trough ERROR MINIMIZATION No slippage of gel sandwich due to in-situ gel casting No migration of samples in wrong direction due to unidirectional feature Wells are not formed at a slant as combs sit leveled on spacers SELECTION GUIDE Model No. of gels at a time width (cm) Gel size length (cm) thickness (mm) No. of wells/ gel Vol/ well (µl) Buffer requirement (ml) Run time (min) Recommended power supply* SLIMPAGE E E ECOPAGE E E Electravolt E *Power supply unit is not included in the ready-to-use systems. Run time is an approximate value for SDS PAGE, 1.5mm thick 10 % gel run at 110 V.
5 Vertical gel apparatus SLIMPAGE Regular model (Cat. No. E ) Regular model has standard electrodes and slim connectors SLIMPAGE-D Deluxe model (Cat. No. E ) Deluxe model has thicker electrodes and stout connectors Single sided model In-situ gel casting No sample loss due to uni-directional migration Gel size: 4 (w) x 8.5 (l) cm Gel thickness: 1.5 mm No. of wells: 4 Buffer requirement: 50 ml 10% SDS-PAGE run in 70 min Slimpage: Vertical electrophoresis, single-sided system of gel size 4 (w) x 8.5 (l) cm, with male connectors, in situ gel casting and uni-directional migration. Slimpage-D: Vertical electrophoresis, single-sided system of gel size 4 (w) x 8.5 (l) cm, with thicker electrodes and stout male connectors, in situ gel casting and unidirectional migration. 1. Lower anodic tank with electrodes and male connector 2. Cathodic electrode unit for in situ gel casting fitted with male connector and electrode 3. Resilient silicone gasket for cathodic electrode unit 4. Two notched and two rectangular glass plates 5. Four 1.5 mm thick, PMMA spacers 6. Two PMMA combs (1.5 mm thick, 4 wells, est. vol. 75 µl/well) 7. of clamps with screws 8. Electrical cords with male & female connectors designed for user safety (1 pair) 9. Instruction manual Suggestion Order along with Ready-to-use system: a Gel-casting stand (E ), Glass plate stand (E ), Gel-sandwich opener (E ), Gel slicer (E ) Refer to page 12 for full list of spares and accessories Vertical gel apparatus ECOPAGE Regular model (Cat. No. E ) Regular model has standard electrodes and slim connectors ECOPAGE-D Deluxe model (Cat. No. E ) Deluxe model has thicker electrodes and stout connectors Single sided model In-situ gel casting No sample loss due to uni-directional migration Gel size: 7 (w) x 8.5 (l) cm Gel thickness: 1.5 mm No. of wells: 8 Buffer requirement: 100 ml 10% SDS-PAGE run in 70 min Ecopage: Vertical electrophoresis, single sided system of gel size 7 (w) x 8.5 (l) cm, with male connectors, in situ gel casting, uni-directional migration. Ecopage: Vertical electrophoresis, single sided system of gel size 7 (w) x 8.5 (l) cm, with with thicker electrodes and stout male connectors, in situ gel casting, unidirectional migration. 1. Lower anodic tank with electrodes and male connector 2. Cathodic electrode unit for in situ gel casting fitted with male connector and electrode 3. Resilient silicone gasket for cathodic electrode unit 4. Two notched and two rectangular glass plates 5. Four 1.5 mm thick, PMMA spacers 6. Two PMMA combs (1.5 mm thick, 8 wells, est. vol. 75 µl/well) 7. of clamps with screws 8. Electrical cords with male & female connectors designed for user safety (1 pair) 9. Instruction manual Suggestion Order along with Ready-to-use system: a Gel-casting stand (E ), Glass plate stand (E ), Gel-sandwich opener (E ), Gel slicer (E ) Refer to page 12 for full list of spares and accessories
6 VERTICAL ELECTROPHORESIS APPARATUS FEATURES ECONOMICAL Less buffer required by virtue of its compact design Short run times as better efficiency of transfer current No cold room required as it can be run in the refrigerator Saves reagent & operator cost as leakage and errors are prevented RUGGED No buffer leakage through plastic joints as bonding is done with special glues Electrodes do not break and pit as they are protected and platinum is >99.9% pure No electrolytic corrosion of male connector as base is resin filled EASY ASSEMBLY Cassette frames can be assembled easily with help of guide pins No slippage during handling of cassette frame, sponge and gel due to locking nuts ERROR MINIMIZATION No migration of samples in wrong direction due to unidirectional feature No wrong assembly of gel sandwich as engraved markings and unidirectional insertion prevent mistakes Electroblotting apparatus NANOBLOT For western blotting (Cat. No. E ) Single cassette Uni-directional insertable cassettes and electrode plates Uni-directional migration Transfer one or two gels at a time Gel size: 6 (w) x 5 (l) cm Buffer requirement: 250 ml Nanoblot: Single cassette western blotting system, can accommodate two gels (gel size 6 (w) x 5 (l) cm with uni directional migration and constructed for cassette and electrode plate insertion in the correct direction only.. 1. Tank 2. Lid 3. Gel & membrane holding cassette with guide pins, stoppers and locking nuts insertable in only one manner 4. Two sponge pads 5. Cathode and anode plates insertable in only one manner, with electrodes for uni-directional migration and male connectors (2 mm) 6. Electrical cords with female (2 mm) & male connectors designed for user safety (1 pair) 7. Instruction manual Refer to page 12 for full list of spares and accessories
7 HORIZONTAL ELECTROPHORESIS APPARATUS FEATURES ECONOMICAL Run larger number of samples per gel Less buffer required by virtue of its compact design Saves reagent & operator cost as leakage and errors are prevented RUGGED Electrodes do not break and pit as they are protected and platinum is >99.9% pure Durable PMMA combs No electrolytic corrosion of male connector as base is resin filled LEAK-PROOF No leakage as tank is a single moulded piece (Slimsub, Ecosub) No leakage from plastic joints as bonding is done with special glues (Tubbysub) ERROR MINIMIZATION Comb removal design minimizes well separator breakage No migration of samples in wrong direction due to unidirectional feature Wells are properly formed as the combs sit levelled on the SELECTION GUIDE Model Description Gel size (w x l) cm Max No. of combs/ gel No. of wells/ comb Max. samples at a time Running length with two combs (cm) Buffer requirement (ml) Recommended power supply* SLIMSUB E /32 E /34 For DNA & protein 3 x ECOSUB E /102 E /104 For DNA & protein 7 x x (with 2 s) Electravolt E TUBBYSUB E /152 E /154 For DNA & protein 15 x / 20 30/ x x (with 2 s) 32 (with 4 s) *Power supply unit is not included in the ready-to-use systems.
8 Horizontal electrophoresis apparatus SLIMSUB Regular model (Cat. No. E ) with UV-opaque (Cat. No. E ) with UV-transparent Regular model has standard electrodes and slim connectors SLIMSUB-D Deluxe model (Cat. No. E ) with UV-opaque (Cat. No. E ) with UV-transparent Deluxe model has thicker electrodes and stout connectors Uni-directional migration For DNA and protein separations Gel size: 3 (w) x 10 (l) cm No. of wells: 4 x (2 combs) Buffer requirement: 100 ml Slimsub: Horizontal apparatus with regular thickness electrodes, 2 mm male connectors, uni-directional migration & UV-opaque, gel size 3 (w) x Slimsub: Horizontal apparatus with regular thickness electrodes, 2 mm male connectors, uni-directional migration & UV-transparent, gel size 3 (w) x Slimsub-D: Horizontal apparatus with 1.7 times thicker electrodes, 4 mm male connectors, uni-directional migration. & UV-opaque, gel size 3 (w) x Slimsub-D: Horizontal apparatus with 1.7 times thicker electrodes, 4 mm male connectors, uni-directional migration. & UV-transparent, gel size 3 (w) x 1. Moulded tank fitted with removable electrodes and male connectors 2. UV-opaque/ UV-transparent for gel size 3 (w) x 10 (l) cm with slots for positioning two combs 3. Two PMMA comb (4 wells, 1.5 mm thick) 4. Lid 5. Electrical cords with male & female connectors designed for user safety (1 pair) 6. Instruction manual Suggestion Order along with Ready-to-use system an extra s (E , E ), extra combs (E ), Gel slicer (E ) Refer to page 12 for full list of spares and accessories Horizontal electrophoresis apparatus ECOSUB Regular model (Cat. No. E ) with UV-opaque (Cat. No. E ) with UV-transparent Regular model has standard electrodes and slim connectors ECOSUB-D Deluxe model (Cat. No. E ) with UV-opaque (Cat. No. E ) with UV-transparent Deluxe model has thicker electrodes and stout connectors Uni-directional migration For DNA and protein separations Gel size: 7 (w) x 10 (l) cm No. of wells: 8 x (2 combs) Buffer requirement: 200 ml Ecosub: Horizontal apparatus with regular thickness electrodes, 2 mm male connectors, uni-directional migration & UV-opaque, gel size 7 (w) x Ecosub: Horizontal apparatus with regular thickness electrodes, 2 mm male connectors, uni-directional migration & UV-transparent, gel size 7 (w) x Ecosub-D: Horizontal apparatus with 1.7 times thicker electrodes, 4 mm male connectors, uni-directional migration. & UV-opaque, gel size 7 (w) x Ecosub-D: Horizontal apparatus with 1.7 times thicker electrodes, 4 mm male connectors, uni-directional migration. & UV-transparent, gel size 7 (w) x 1. Moulded tank fitted with removable electrodes and male connectors 2. UV-opaque/UV-transparent for gel size 7 (w) x 10 (l) cm with slots for positioning two combs 3. Two PMMA combs (8 wells, 1.5 mm thick) 4. Lid 5. Electrical cords with male & female connectors designed for user safety (1 pair) 6. Instruction manual Suggestion Order along with Ready-to-use system an extra s (E , E , E , E ), extra combs (E , E ), Gel slicer (E ) Refer to page 12 for full list of spares and accessories
9 Horizontal electrophoresis apparatus TUBBYSUB Regular model (Cat. No. E ) with UV-opaque (Cat. No. E ) with UV-transparent Regular model has standard electrodes and slim connectors TUBBYSUB-D Deluxe model (Cat. No. E ) with UV-opaque (Cat. No. E ) with UV-transparent Deluxe model has thicker electrodes and stout connectors Uni-directional migration For DNA and protein separations Gel size: 15 (w) x 10 (l) cm No. of wells: 15/20 x (2 combs) Buffer requirement: 500 ml Tubbysub: Horizontal apparatus with regular thickness electrodes, 2 mm male connectors, uni-directional migration & UV-opaque, gel size 15 (w) x Tubbysub: Horizontal apparatus with regular thickness electrodes, 2 mm male connectors, uni-directional migration & UV-transparent, gel size 15 (w) x Tubbysub-D: Horizontal apparatus with 1.7 times thicker electrodes, 4 mm male connectors, uni-directional migration. & UV-opaque, gel size 15 (w) x Tubbysub-D: Horizontal apparatus with 1.7 times thicker electrodes, 4 mm male connectors, uni-directional migration. & UV-transparent, gel size 15 (w) x 1. Tank fitted with removable electrodes and male connectors 2. UV-opaque /UV-transparent for gel size 15 (w) x 10 (l) cm with slots for positioning two combs 3. Two PMMA comb (15 wells, 1.5 mm thick) 4. Lid 5. Electrical cords with male & female connectors designed for user safety (1 pair) 6. Instruction manual Suggestion Order along with Ready-to-use system: extra s (E , E , E ), extra combs (E , E , E , E ) Refer to page 12 for full list of spares and accessories
10 UV-TRANSILLUMINATOR FEATURES ECONOMICAL Low capital cost of equipment and for the spares Does not need costly UV-transparent violet filter RUGGED Non brittle filter made of plastic which does not crack easily No solarization i.e. UV-transparency of UV-transparent diffuser window is unchanged over time HIGH SENSITIVITY Visual detection limit one ng per compact band of EtBr stained dsdna due to intensity of UVA tubes UV-transparent diffuser window allows 85-90% of the UV to pass through SAFETY No skin burns/ damage to retina due to UV protective shield, chromafilter & UVA tubes Negligible photo-nicking of DNA due to use of lower energy UVA lights Dual (hi-lo) mode for viewing. Go to high mode only when required. UV-transilluminators GLOWORM-2 2UVA tubes (Cat. No. E ) GLOWORM-4 4 UVA tubes (Cat. No. E ) Compact dark viewing hood with Chromafilter to improve contrast Negligible photo-bleaching and photo-nicking of DNA 366 nm UVA is less hazardous to retina & skin than 302 nm UVB Window size: 10 (w) x 10 (l) cm Switch for dual intensity Sensitivity 1 ng per band Gloworm-2: UV-transilluminator with diffusing UV-transparent window (10 x 10 cm), two UVA tubes, Hi-Lo intensity control and trapezoid hood fitted with binocular chromafilter eyepiece. Glowrom-4: UV-transilluminator with diffusing UV-transparent window (10 x 10 cm), four UVA tubes Hi-Lo intensity control and trapezoid hood fitted with binocular chromafilter eyepiece.. 1. Housing unit with a diffusing UV-transparent window 2. UV-protective shield 3. UVA-tubes (2 tubes in Gloworm-2; 4 tubes in Gloworm-4) 4. Compact trapezoid dark viewing hood with removable binocular chromafilter eyepiece 5. Instruction manual Suggestion Upgrade to EcoDoc (E ), the economic way of gel documentation Refer to page 12 for full list of spares and accessories
11 Gel Documentation ECODOC (Cat. No. E ) UV-transparent window Switch for dual intensity of UV-light Compact hood with attachment for camera Illumination area size: 10 (w) x 10 (l) cm 366 nm UVA tubes EcoDoc: Economic gel documentation system with UVA light source and hi-lo light intensity control, 10 x 10 cm window, compact hood fitted with camera. 1. Lower housing unit with a UV-transparent window 2. Four UVA-tubes 3. A compact hood fitted with camera 4. Instruction manual Power Supply ELECTRAVOLT Output voltages 80, 110, 140, 170 & 200 (Cat. No. E ) Voltage range designed for optimal running of small vertical & horizontal gels Negligible voltage dip on connecting to instrument Corrosion resistant body Size: 12 (l) x 12 (b) x 11(h) cm Single output Electravolt: Power supply with five fixed voltages (80, 110, 140, 170 & 200 V) and single output 1. Power supply 2. Electrical cord attached Features 1. Floating secondary in transformer prevents electrical shock via ground 2. Current limit to prevent over heating of gels 3. Plastic body to prevent electrical shock
12 STAND FOR MICROPIPETTES Cat. No. E Accomodates 4 micropipettes at a time Pippettes maintained at a convenient slant Holds box of 200 ul micropipette tips at the rear MICRO-TEST TUBES STAND Cat. No. E For 1.5 and 2 ml microcentrifuge tubes Holds 10 tubes at a time TIP & TUBE DISCARD CONTAINER Cat. No. E Rectangular box of thick clear acrylic Non-spill lid with 3 cm dia discard hole and flip-flop cover MICROBIAL CHEMOTAXI CHAMBER Cat. No. E Two tracks per chamber Each track has two wells (50 µl) joined by 25 mm long channel for capillary tube Size: 5 x 3 cm Autoclavable GEL SANDWICH OPENER Cat. No. E For separating the notch plate and rectangular plate AGAROSE DISPENSER Cat. No. E For convenient sealing of vertical gel apparatus with agarose
13 GEL SLICER Cat. No. E Size: 6.5 (w) x 15 (l) cm Breakage resistant ELECTRICAL CORDS with 2 mm female and 4 mm male connectors Cat. No. E With male and female connectors Designed for user safety ELECTRICAL CORDS with 4 mm female and male 4 mm connectors Cat. No. E With male and female connectors Designed for user safety GRADIENT MIXER Cat. No. E Triple-barrel Volume per chamber 14 ml Leak-proof plunging stopper Accomodates a magnetic spin-bar of length 10 mm LEVELLING TABLE Cat. No. E x 21 cm Novel penta-legged design for compactness With spirit-level
14 SlimPage and its accessories E Slimpage, ready-to-use system E Slimpage-D, ready-to-use system E Clamps with screws (one pair) E Screws for clamps and CEU (two of each) E Silicone gasket for cathodic electrode unit E Comb 1.5 mm thick, PMMA, 4 wells E Spacers, 1.5 mm thick, PMMA (one pair) E Notched and rectangular glass plate, 8 (w) x 8.5 (l) cm (one of each) E Gel-casting stand with binder clips E Glass plate stand EcoPage and its accessories E Ecopage, ready-to-use system E Ecopage-D, ready-to-use system E Clamps with screws (one pair) E Screws for clamps and CEU (two of each) E Silicone gasket for cathodic electrode unit E Comb 1.5 mm thick, PMMA, 8 wells E Spacers, 1.5 mm thick, PMMA (one pair) E Notched and rectangular glass plate, 11 (w) x 8.5 (l) cm (one of each) E Gel-casting stand with binder clips E Glass plate stand NanoBlot and its accessories E Nanoblot, ready-to-use system E Cathode and anode plates with male connectors (2 mm), uni-directional insertion and migration feature E Gel membrane-holding cassette with guide-pins, stoppers and locking nuts E Sponge pads (four) Packet E Guide pins with stoppers and locking nuts (two of Packet each) SlimSub and its accessories E Slimsub, ready-to-use system with UV-opaque E Slimsub, ready-to-use system with UVtransparent E Slimsub-D, ready-to-use system with UV-opaque E Slimsub-D, ready-to-use system with UVtransparent E Cathode (black) and anode (red) electrode plates with 2 mm male connectors E Cathode (black) and anode (red) electrode plates with 4 mm male connectors E UV-opaque [3 (w) x 10 (l) cm] E UV-transparent [3 (w) x 10 (l) cm] E Comb 1.5 mm, PMMA, 4 well for 3 cm wide gel EcoSub and its accessories E Ecosub, ready-to-use system with UV-opaque E Ecosub, ready-to-use system with UV-transparent E Ecosub-D, ready-to-use system with UV-opaque E Ecosub-D, ready-to-use system with UVtransparent E Cathode (black) and anode (red) electrode plates with 2 mm male connectors E Cathode (black) and anode (red) electrode plates with 4 mm male connectors E UV-opaque [7 (w) x 10 (l) cm] E UV-transparent [7 (w) x 10 (l) cm] E UV-opaque [gel size 3 (w) x 10 (l) cm] E UV-transparent [gel size 3 (w) x 10 (l) cm] E Comb 1.5 mm, PMMA, 8 well for 7 cm wide gel E Comb 1.5 mm, PMMA, 4 well for 3 cm wide gel TubbySub and its accessories E Tubbysub, ready-to-use system with UV-opaque E Tubbysub, ready-to-use system with UVtransparent E Tubbysub-D, ready-to-use system with UVopaque E Tubbysub-D, ready-to-use system with UVtransparent E Cathode (black) and anode (red) electrode plates with 2 mm male connectors E Cathode (black) and anode (red) electrode plates with 4 mm male connectors E UV-opaque [3 (w) x 10 (l) cm] E UV-transparent [3 (w) x 10 (l) cm] E UV-opaque [7 (w) x 10 (l) cm] E UV-transparent [7 (w) x 10 (l) cm] E UV-opaque [15 (w) x 10 (l) cm] E UV-transparent [15 (w) x 10 (l) cm] E Comb 1.5 mm, PMMA, 4 well for 3 cm wide gel E Comb 1.5 mm, PMMA, 8 well for 7 cm wide gel E Comb 1.5 mm, PMMA, 15 well for 15 cm wide gel E Comb 1.5 mm, PMMA, 20 well for 15 cm wide gel UV-transilluminators and its accessories E Gloworm-2, ready-to-use system E Gloworm-4, ready-to-use system E UVA tubes for Gloworm-2 (2 No.) E UVA tubes for Gloworm-4 (4 No.) E Compact trapezoid dark viewing hood (for Unit window size 10 x 10 cm), height 15 cm with detachable binocular chromafilter eyepiece for GLOWORM-2/4 E Detachable binocular chromafilter eyepiece for trapezoid dark viewing hood Gel Documentation system E Ecodoc: gel documentation system. Power supply E Electravolt: Power supply with five fixed voltage outputs of 80, 110, 140, 170, 200 Labware E Stand for micropipettes E Micro-test tube stand Unit E Tip & tube discard container Unit E Microbial chemotaxis chamber E Gel-sandwich opener E Agarose dispenser E Gel-slicer, breakage resistant, 6.5 (w) x 15 (l) cm E Electrical cords with male & female (2 mm) connectors designed for user safety E Electrical cords with male & female (4 mm) connectors designed for user safety E Gradient mixer E Penta-legged levelling table
15 Economic Separations Product Catalog Contact us at Horizontal Electrophoresis Apparatus Vertical Electrophoresis Apparatus Electroblotting Apparatus UV-Transilluminators Gel-Documentation Power Pack Website Reg. Office Address: TechResource, 188 Nagdevi Street, 2 nd Floor, Mumbai
Standard Casting Stand Combination Comb Holder Wide/Long Combination Casting Stand
@ Standard Casting Stand Combination Comb Holder Wide/Long Combination Casting Stand Instruction Manual Catalog Numbers 170-3689, 170-3699, and 170-3704 For Technical Service Call Your Local Bio-Rad Office
More informationMini-Vertical Gel Electrophoresis System for Precast Gel
Mini-Vertical Gel Electrophoresis System for Precast Gel Installation and Operation Manual Version 1.0 Item# 01140 *This instrument is intended for laboratory use only Index A. Important Notice ---------------------------------------------------------------
More informationV-GES operation. Technical Bulletin E-02 MATERIAL PROCEDURE
V-GES operation MATERIAL BSA (1 mg/ml), 0.05 g BSA (Sigma-Aldrich Ltd., St Louis, MO; U.S.A.) dissolved in 50 ml ddh 2 O, aliquot 1 ml solution per Eppendorf and freeze in -20. Pre-stained marker (Bio-Rad,
More informationSmartDoc 2.0 E5001-SDB Instruction Manual
SmartDoc 2.0 E5001-SDB Instruction Manual Version 11.16 1 Table of Contents 1. Introduction 3 2. Warnings. 3 3. Unpacking.. 4 4. SmartDoc 2.0 Overview 4 5. Setting up the SmartDoc 2.0 5 6. Gel Viewing
More informationFlat Sample Holder Part Number
Flat Sample Holder Part Number 990-00403 (Patent Pending) Operator s Manual Copyright 2016 Gamry Instruments, Inc. April 8, 2016 988-00043 Rev. 1 If You Have Problems Please visit our service and support
More informationSLIDING DOOR SYSTEM_ S34 PRODUCT LIST. System description Accessories
SLIDING DOOR SYSTEM_ S34 PRODUCT LIST System description Accessories SLIDING DOOR SYSTEM_ S34 1.0_ System description_ page 03 2.0_ Profiles_ page 04 3.0_ Profile finishes_ page 08 4.0_ Panels_ page 09
More informationLED Series Sealed High-Intensity Area Lights
Datasheet High-Power Lighting for use with Banner Vision Systems To view or download the latest technical information about this product, including specifications, dimensions, accessories, and wiring,
More informationCasting and running of 15% PAGE gel
igem TU/e 2014 Biomedical Engineering Eindhoven University of Technology Room: Ceres 0.04 Den Dolech 2, 5612 AZ Eindhoven The Netherlands Tel. no. +31 50 247 55 59 2014.igem.org/Team:TU_Eindhoven Casting
More informationRound Indicator Lights Mounting Hole Page
PRODUCT SERIES Round Indicator Lights Page 8, &. 9. &..7 - NEMA -R.7 8 & 9. 7. 8. 9 7. 8. - NEMA -R.9.9 Indicator Lights.7,.. 7. Rectangular Indicator Lights Panel Cutout. x.. x. 7 & 7. x.8 8. x. 9 & 7.
More informationSLIDING DOOR SYSTEM_ S42 PRODUCT LIST. System description Accessories
SLIDING DOOR SYSTEM_ S42 PRODUCT LIST System description Accessories 1 SLIDING DOOR SYSTEM_ S42 1.0_ System description_ page 03 2.0_ Profiles_ page 04 3.0_ System description S1600 fixed panels_ page
More informationSection 11 CABLE & ROD SYSTEMS, SIGN FIXING & SIGN STANDOFFS. Web. acrylicdesign.ie .
Section 11 CABLE & ROD SYSTEMS, SIGN FIXING & SIGN STANDOFFS Web. acrylicdesign.ie Email. sales@acrylicdesign.ie Acrylic Design 2004-2015 Mobile Cable System Components Single panel clamp Stand Off for
More informationOwner s Manual #TSGUARD
Owner s Manual #TSGUARD PSI Table Saw Dust Collection Guard The ideal solution for table saw dust control. Version 3, 02/04 2004 PSI Woodworking Products 9900 Global Rd., Philadelphia, PA 19115 WARRANTY
More informationQ-Zone Hoop-Frame. Assembly Instructions. Copyright July 11, 2018 Grace Company (Reproduction Prohibited) Version 1.8
Q-Zone Hoop-Frame Assembly Instructions Copyright July 11, 2018 Grace Company (Reproduction Prohibited) Version 1.8 Table of Contents Table of Contents... i Warranty... ii Parts List Box 1...iii Box 2...
More informationUytengsu Teaching Lab Consumable Inventory
116.11 Absorbant Pads 130.57; 116.18; 112C.20; 114.50 Aluminum foil 112C.40 Anaerobic culture 116.74 Arktik Thermal Cycler Accessories Autoclavable bags 112.1; 114.48 Batteries 116.104 Beakers, Glass 118.46;
More informationATLAS O Pratt Truss Bridge Parts List For Either Single or Double Track Styles
FIG. 12 Underside Crossmember Joiner (Install this first) ATLAS O Pratt Truss Bridge Parts List For Either Single or Double Track Styles Apply glue to underside of tab in this location. Apply glue to peg
More informationFig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7
FSW Installation instructions Track rail 75 x 72 mm 1. Ceiling substructure and installation of the track rail (Fig. 1): The track rail must be bolted over its entire length (including the stacking track
More informationInstallation Instructions
Installation Instructions Alcove Enclosure Before Installation please check that your shower enclosure system is undamaged Please read these instructions carefully March 2015 TOOLS REQUIRED Electric or
More informationDeauville Installation Guide
vjul16 (for 17 or 24 mm Surface Wall Profiles) DO NOT ASSEMBLE WITHOUT FULLY READING THESE INSTRUCTIONS Page 2 Thank you for purchasing this Deauville shower enclosure. Please study these instructions
More informationFastGene Blue White LED Tab Catalogue Number FG-12
FastGene Blue White LED Tab Catalogue Number FG-12 Revision 1.0 (10/2017) CONTENT SAFETY INFORMATION 3 WARRANTY 3 REGULATORY NOTICE 4 IMPORTANT NOTICE 4 SPECIFICATION 4 NOMENCLATURE 5 INSTALLATION AND
More informationV00029KX READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID
READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID Net-Verse D-Type Cabinets Tool List 10mm Socket Wrench 122mm (48 ) Level 19mm Wrench 8mm Hex Drive T25 Torx driver Net-Verse D-Type
More informationASSEMBLY INSTRUCTIONS FOR SERVICE BODY A MOUNT RACKS
ASSEMBLY INSTRUCTIONS FOR SERVICE BODY A MOUNT RACKS T12 Service Body A shown with optional middle crossbar Package Contents: HARDWARE KIT PARTS (8) 3/8-16 x 3 CARRAIGE BOLTS (1) RAIL DRIVER S SIDE ASSEMBLIES
More informationSpecimen Preparation Glass Microspray - Atomiser. BEEM Block Holder Module. Microtome Chuck - Flat Embedding Mould. BEEM Flat Embedding Mould
Glass Microspray - Atomiser Designed to atomise very small volumes of liquid, the spray is valuable in preparing virus and protein suspensions and a wide variety of other particle preparations. The spray
More informationWebsite:- - S.No. Items Price
BT 100 ANAEROBIC CULTURE JAR, Stainless Steel BTL Type 15000.00 (Modified Mcintosh and Fildes pattern) Top Flange Recessed For A Torodial Rubber Sealing Ring & A Cover Held By A Strong Bridge Clamp. Cover
More informationOPTISENS PH 8100 Technical Datasheet
OPTISENS PH 8100 Technical Datasheet ph sensor High quality and precise glass sensor for usage in low conductivity media High temperature resistency Suitable for application in chemical industry The documentation
More informationMaxiMist SprayMate Pro HVLP TANNING SYSTEM
MaxiMist SprayMate Pro HVLP TANNING SYSTEM DO NOT USE EQUIPMENT BEFORE READING THIS MANUAL This manual contains important warnings and instructions. Please read these instructions carefully and keep for
More informationMP573 Assembly guide. Soldering. MP573 Assembly guide PCB split PCB split. Document revision 2.2 Last modification : 22/08/17
MP573 Assembly guide Safety warning The kits are main powered and use potentially lethal voltages. Under no circumstance should someone undertake the realisation of a kit unless he has full knowledge about
More information2D Protein Gel Image Capture and Analysis
2D Protein Gel Image Capture and Analysis the way you want it S Y N G E N E A DIVISION OF THE SYNOPTICS GROUP 2D protein gel generation, image capture and analysis systems Syngene has a worldwide reputation
More informationCONNECTORS, ELECTRICAL, CIRCULAR, TRIPLE-START SELF-LOCKING COUPLING, SCOOP-PROOF, REMOVABLE CRIMP CONTACTS BASED ON MIL-C SERIES III
Page 1 of 24 CONNECTORS, ELECTRICAL, CIRCULAR, TRIPLE-START SELF-LOCKING COUPLING, SCOOP-PROOF, REMOVABLE CRIMP CONTACTS BASED ON MIL-C-38999 SERIES III ESCC Detail Specification Issue 6 October 2013 Document
More informationASSEMBLY INSTRUCTIONS FOR HAULER II SERVICE BODY A RACK
ASSEMBLY INSTRUCTIONS FOR HAULER II SERVICE BODY A RACK T12USBA-1 shown above Package Contents: HARDWARE KIT PARTS (4) 3/8-16 x 3 CARRAIGE BOLTS (1) RAIL DRIVER S SIDE ASSEMBLY (20) 3/8-16 x 2 CARRAIGE
More informationINSTALLATION INSTRUCTIONS JEEP SCRAMBLER FAST TRAC TOP PART #108-21X
INSTALLATION INSTRUCTIONS JEEP SCRAMBLER FAST TRAC TOP PART #108-21X Thank you for purchasing Specialty s Convertible Top for your Jeep vehicle. It has been designed for great fit and long wear. Please
More informationMAXIMIST ULTRA PREMIER HVLP SPRAY TANNING SYSTEM
MAXIMIST ULTRA PREMIER HVLP SPRAY TANNING SYSTEM DO NOT USE EQUIPMENT BEFORE READING THIS MANUAL This manual contains important warnings and instructions. Please read these instructions carefully and keep
More informationSECTION INTERIOR SIGNAGE
SECTION 10 14 02 INTERIOR SIGNAGE PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by
More informationIMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY For Outdoor Use Only
ITEM#: FG-SNP4272TBL17 San Paulo 42 x72 Oval Dining Table IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY For Outdoor Use Only Customer Service E-Mail : customerservice@foremostgroups.com 8:30a.m.
More informationPortofino Installation Guide
vjul16 (for 17 or 24 mm Surface Wall Profiles) DO NOT ASSEMBLE WITHOUT FULLY READING THESE INSTRUCTIONS Page 2 Thank you for purchasing this Portofino shower enclosure. Please study these instructions
More informationJosephson Engineering, Inc. 329A Ingalls Street Santa Cruz, California Josephson Engineering Rev B
C725 Users Guide Josephson Engineering, Inc. 329A Ingalls Street Santa Cruz, California +1 831 420 0888 www.josephson.com 2017 Josephson Engineering Rev B C725 Users Guide Josephson C725 microphones are
More informationSorenson Lighted Controls
Sorenson Lighted Controls Illuminating Innovation 9 INDICATOR CATALOG New Products Located on Pages - Sorenson Lighted Controls Illuminating Innovation ORDER TERMS & CONDITIONS Minimum OEM Order Value:
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationPRODUCT SAFETY SOLUTIONS MODEL HWI-01. Model HWI-01 Serial Number:
USER S MANUAL HOT WIRE IGNITION TESTER MODEL HWI-01 Model HWI-01 Serial Number: 1 HWI-01 HOT WIRE IGNITION TESTER IMPORTANT INSTRUCTIONS - - SAVE THESE INSTRUCTIONS Introduction Thank you for choosing
More informationMini-PROTEAN Electrophoresis System
Protein Electrophoresis Mini-PROTEAN Electrophoresis System Welcome to the Fast Lane 02 Mini-PROTEAN System Mini-PROTEAN Electrophoresis System Welcome to the Fast Lane For more than years, the Mini-PROTEAN
More informationWLS28-2 UV LED Strip Light
WLS8- UV LED Strip Light Datasheet Banner's WLS8- UV LED Strip Lights have sturdy aluminum housings, shatterproof windows, and impressive environmental ratings, making them a cost-effective operator inspection
More informationThe Phoenix. Professional Quilting Frame. Copyright January 1, 2016 Jim M. Bagley, GraceWood, Inc (Reproduction Prohibited) Version 2.
The Phoenix Professional Quilting Frame Copyright January 1, 2016 Jim M. Bagley, GraceWood, Inc (Reproduction Prohibited) Version 2.1 1 The Phoenix Professional Quilting Frame Parts List Box 1...3 Box
More informationDNA Size Selection Magnetic Beads
DNA Size Selection Magnetic Beads Catalog #: 801-117 User Manual Last revised July 30 th, 2018 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607 Parkway Lane, Suite 100 Norcross,
More informationRead Below! Read Below! Read Below! Read Below! Read Below! Read Below! STOP READ TIPS BELOW TO MAKE ASSEMBLY MUCH EASIER
Read Below! Read Below! Read Below! Read Below! Read Below! Read Below! STOP READ TIPS BELOW TO MAKE ASSEMBLY MUCH EASIER Here are some guidelines to help make assembling your unit much easier: -Read and
More informationDeauville Installation Guide
vjul16 (for Recessed Wall Profiles) DO NOT ASSEMBLE WITHOUT FULLY READING THESE INSTRUCTIONS Page 2 Thank you for purchasing this Deauville shower enclosure. Please study these instructions carefully before
More informationTransilluminators: UV light, White light (WE-LED), Blue Light (BE-LED) Made in Germany Made by Herolab NEW
Transilluminators: UV light, White light (WE-LED), Blue Light (BE-LED) Made in Germany Made by Herolab Standard Class For use in all fields NEW Advanced Class Multiwave / Variable Intensity High Contrast
More informationAllora ALCOVE ENCLOSURE INSTALLATION BEFORE INSTALLATION CHECK THAT YOUR ALLORA SHOWER ENCLOSURE SYSTEM IS UNDAMAGED
Allora ALCOVE ENCLOSURE INSTALLATION BEFORE INSTALLATION CHECK THAT YOUR ALLORA SHOWER ENCLOSURE SYSTEM IS UNDAMAGED ALCOVE SHOWER Your shower can be installed to open Left hand or Right hand by rotating
More informationMAXIMIST ULTRA PRO HVLP SPRAY TANNING SYSTEM
MAXIMIST ULTRA PRO HVLP SPRAY TANNING SYSTEM DO NOT USE EQUIPMENT BEFORE READING THIS MANUAL This manual contains important warnings and instructions. Please read these instructions carefully and keep
More informationGE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -
at :: rangehoods. com GE Monogram Instructions Model ZV750 GE Monogram at:: rangehoods. com is a division of CAUTION WARNING Before you begin Read these instructions completely and carefully. IMPORTANT:
More informationASSEMBLY OF THE KNOCKED-DOWN LADDERS: 8 to 12 STEPS STANDARD TOP AND SAFELOCK REQUIRED TOOLS
ASSEMBLY OF THE KNOCKED-DOWN LADDERS: 8 to 12 STEPS STANDARD TOP AND SAFELOCK REQUIRED TOOLS SAFETY GLASSES 7/16" WRENCH OR SOCKET STEP LADDER OF APPROPRIATE HEIGHT (2) 9/16" WRENCHES OR SOCKETS RUBBER
More informationMonaco Installation Guide - Surface Profiles
v1 Page 1 Thank you for purchasing this Monaco shower screen. Please study these instructions carefully before assembly and installation and check all supplied parts immediately upon receipt. These instructions
More informationModels 2230 and 2240
Models 2230 and 2240 Overview... 2 Tools Needed... 2 Hardware...3 Assembly... 4-13 Installation... 14 Drawer Removal... 15 Operation... 15 Maintenance... 15 Accessories... 16 Limited Warranty... 16 Perform
More informationASPEN OUTDOOR TABLE TENNIS
ASPEN OUTDOOR TABLE TENNIS Replacement Parts Order direct at or call our Customer Service department at (800) 225-7593 8 am to :30 pm Central Standard Time January 201 UPC Code 7-19265-51830-3 Staple your
More informationBullet EL Volt Die-Cast Aluminum, PAR38 Incan. / Halogen / R40 Incan. revision 8/15/11 el220.pdf
Catalog number: and Finish Options: See page 2 ing Options: See pages 3-5 Approvals: Date: Page: 1 of 5 Specifications Housing: Die-cast low copper aluminum. Swivel: Die-cast aluminum with locking teeth
More informationMODEL 402 PORTA-NAILER For Tongue and Groove Solid Wood & Hardwood Laminate Flooring
ACCESSORIES cont d. Cat. No. 42626 Angled Shoe Base for Nailing 3/4 Flooring over 3/4 Plywood over Concrete OWNER S MANUAL MODEL 402 PORTA-NAILER For Tongue and Groove Solid Wood & Hardwood Laminate Flooring
More informationHELIX PLANETARY GRINDER M2000 GRINDERS AND POLISHING SYSTEMS. Designed for small jobs and tough-to-reach spaces, this
HELIX PLANETARY GRINDER M2000 GRINDERS AND POLISHING SYSTEMS Designed for small jobs and tough-to-reach spaces, this new coatings. This easy-to-operate machine features an edge grinder, dual speed operation,
More informationThis product is designed for a water supply pressure range of 20 psi (137kPa) minimum to 80psi (550 kpa) maximum.
We appreciate your commitment to Kohler quality. Please take a few minutes to review this manual before you start installation. If you encounter any installation or performance problems, please don t hesitate
More informationPLEASE CHECK ALL BOXES FOR HARDWARE BEFORE DISCARDING
Thank you for purchasing the SleepSafe Safety Bed. With proper care, your bed will provide years of safe use. Carefully unpack all the contents of your bed and verify that all parts are included using
More informationMaintenance and other important non-personal injury and non-material damage instructions or statements that should be observed.
VIGO INDUSTRIES INSTALLATION GUIDE FOR SHOWER ENCLOSURE ()! SAFETY PRECAUTIONS This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated
More informationMODEL SETUP & OPERATION MANUAL DOVETAIL JIG FEATURES SPECIFICATIONS
SETUP & OPERATION MANUAL FEATURES Male and female dovetail joints are cut simultaneously, to ensure perfectly matched dovetail joints. Side stops provided, allow repeated precise dovetail joint cutting
More informationUsing Your Chip Priming Station
s1 Using Your Chip Priming Station The Chip Priming Station, part number 5065-4401, is for use with the Agilent 2100 Bioanalyzer LabChip Kits. Refer to Figure 1 and 2 for a picture of the Chip Priming
More informationUVA-Star Tube Lamps Curing UV adhesives when bonding glass/glass
UVA-Star Tube Lamps Curing UV adhesives when bonding glass/glass www.bohle.com For prices and up-to-date drawings, please visit our Online Shop. Foto: Tonelli 2 Bohle offers an extensive range of UVA lamps
More informationPortofino Case2 Installation Guide
Portofino Case2 Installation Guide vjun16 (for 17 or 24 mm Surface Wall Profile) DO NOT ASSEMBLE WITHOUT FULLY READING THESE INSTRUCTIONS Page 2 Thank you for purchasing this Portofino Case 2 shower enclosure.
More informationINSTRUCTION MANUAL. In vivo Test Apparatus for 305B Muscle Lever Systems
INSTRUCTION MANUAL Model 806A In vivo Test Apparatus for 305B Muscle Lever Systems May 18, 2005, Revision 3 Copyright 2005 Aurora Scientific Inc. Aurora Scientific Inc. 360 Industrial Parkway S., Unit
More informationRead Below! Read Below! Read Below! Read Below! Read Below! Read Below! STOP READ TIPS BELOW TO MAKE ASSEMBLY MUCH EASIER
Read Below! Read Below! Read Below! Read Below! Read Below! Read Below! STOP READ TIPS BELOW TO MAKE ASSEMBLY MUCH EASIER Here are some guidelines to help make assembling your unit much easier: -Read and
More informationSpa & Hot Tub Necessities. Cover Removal System Installation & Use Manual
Spa & Hot Tub Necessities Cover Removal System Installation & Use Manual SET-UP AND ASSEMBLY BEFORE BEGINNING ASSEMBLY, CAREFULLY READ THE FOLLOWING INFORMATION AND INSTRUCTIONS: Place all parts in a cleared
More informationShannon s CCR Spiral Tree
Shannon s CCR Spiral Tree http://www.shannonclaus.com Disclaimer: I take no responsibility for design failures or injuries related to this design. This document is created for informational purposes only
More informationInstallation Instructions TrekStep Side Mount
Installation Instructions TrekStep Side Mount Vehicle Application Chevrolet Silverado / GMC Sierra All Bed Sizes 1999 Current Part Number: 75400-15 www.bestop.com - We re here to help! Visit our web site
More informationPortable System Owners Manual Customer Service Center N53 W24700 South Corporate Circle Sussex, WI U.S.A.
Portable System Owners Manual Customer Service Center N53 W24700 South Corporate Circle Sussex, WI 53089 U.S.A. Adult Assembly Required. This manual, accompanied by sales receipt, should be saved and kept
More informationMidmark Stainless Steel Cages Setup Manual
Midmark Stainless Steel Cages Setup Manual Table of Contents Pre-Installation......................... 2 Parts Identification..................... 2-3 Base Construction....................... 3 Assembly............................
More informationITEM#:DNSW5102J PK IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY. St. Thomas Swivel Rocking Dining Chair
ITEM#:DNSW5102J-48019-2PK IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY St. Thomas Swivel Rocking Dining Chair Customer Service E-Mail : customerservice@foremostgroups.com 8:30a.m. 5:00p.m. EST,
More informationCONTENTS CABLE MANAGEMENT AND
CONTENTS CABLE MANAGEMENT SECTION 9 SECTION 9 CABLE MANAGEMENT AND ASSOCIATED PRODUCTS.................................91 PIN CLIPS H335B SERIES.......................................92 COPPER EARTH RODS.........................................92
More informationAssembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set #
Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set #1002493 JET 427 New Sanford Road LaVergne, Tennessee 37086 Part No. M-708482 Ph.: 800-274-6848 Revision C3 02/2014 www.jettools.com
More informationINSTRUCTIONS FOR ASSEMBLY AND OPERATION OF ERMA MICROTOME
OPERATING MANUAL, ERMA RADIAL INSTRUCTIONS FOR ASSEMBLY AND OPERATION OF ERMA MICROTOME Upon receipt of your Erma Microtome please check the contents of the packages (s). These are itemized below: 1. Microtome
More informationCONTENTS THE ADVANCE PASTEMATE ADVANTAGES ENGLISH
THE ADVANCE PASTEMATE ADVANTAGES Introduced in September 1981, thousands in service, known for reliability and performance. Setup and clean-up is faster than any other paste machine, which means more production.
More informationA great addition to Sub-Zero's complete line of
with Refrigeration Drawers Discreet lighting Full-view glass door (standard) Roller-assembly shelves UV-resistant glass Lighted electronic control panel Divider gasket Model 427R Lighted display shelf
More informationHardware Fitting Accessories Door Seals
Areas of application Protection against cold, draught and vermin Reduces light leakage, sound insulation Smoke control, fire resistance Reduces the energy consumption of air conditioning systems (see following
More informationMX150L tm INDUSTRIAL SEALED CONNECTOR SYSTEM
MX150L tm INDUSTRIAL SEALED CONNECTOR SYSTEM The MX150L Industrial Sealed Connector System is IP67 rated and conforms to UL 1977, but it is NOT suitable for automotive applications with requirements such
More informationSensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m
Photoelectric Sensor with Built-in Amplifier CSM DS_E 1 General-purpose Photoelectric Sensor for High Quality and Reliable Detection Be sure to read Safety Precautions on page 8. Ordering Information General-purpose
More informationCurium 19H Installation Instructions & Parts List
Curium 19H Installation Instructions & Parts List Illustration Curium 19H Right Hand Page 1 of 15 01/07/2016 Revision 2.1 IMPORTANT This shower screen / enclosure must be installed by suitably qualified
More informationMelting point range. A complete range of melting points to accomodate all users
Melting point range A complete range of melting points to accomodate all users SMP40, Automatic Melting Point In recent years, Stuart has become the laboratory name in melting points. For the first time,
More informationModels 2030 and 2040
Models 2030 and 2040 Overview... 2 Tools Needed... 2 Hardware... 2 Assembly... 3-8 Installation... 9 Operation... 9 Maintenance... 10 Accessories... 10 Limited Warranty... 10 Document # 101290 0607 Printed
More informationPortable System Owners Manual
Portable System Owners Manual Customer Service Center N53 W24700 South Corporate Circle Sussex, WI 53089 U.S.A. Adult Assembly Required. This manual, accompanied by sales receipt, should be saved and kept
More informationJob no. 5241_Accessories Brochure_Size: 8.2 x 8.2 _ KOHLER Genuine Accessories
KOHLER Genuine Accessories CHOOSING THE PERFECT WALL-HUNG TOILET FOR YOUR BATHROOM IS N0T ENOUGH. KOHLER presents a range of accessories to enhace your bathroom experience. INSTAFIT+ Specially designed
More informationCare and Use of the VP 407AM-N 96 Pin Magnetic Bead Extractor
TECHNICAL NOTE 310 Care and Use of the VP 407AM-N 96 Pin Magnetic Bead Extractor Cover Plate VP 407AM-N-PCR (purchase separately) Magnetic Bead Extractor VP 407AM-N Loading Frame For Cover Plate (included)
More informationWLS28-2 Dual Color LED Strip Light
WLS8- Dual Color LED Strip Light Datasheet Banner s LED Strip Lights have sturdy aluminum housings, shatterproof windows, and impressive environmental ratings, making them an ideal general-purpose LED
More informationOperating Instructions and Parts Manual Hydraulic Shop Presses Models HP-5A/15A/35A
Operating Instructions and Parts Manual Hydraulic Shop Presses Models HP-5A/15A/35A Model HP-35A shown JET 427 New Sanford Road LaVergne, Tennessee 37086 Part No. M-331406 Ph.: 800-274-6848 Revision D
More informationPNP. 5 to 800 mm sensor to reflector distance on BRT-60x40C NPN
Datasheet Coaxial polarized retroreflective sensor for clear object detection Reliable detection of clear, translucent, or opaque objects including PET and glass containers, transparent films, and mirror-like
More informationCHAINSAW LOG HORSE MODEL NO: CCLH1
CHAINSAW LOG HORSE MODEL NO: CCLH1 Part No: 3402085 ASSEMBLY & OPERATING INSTRUCTIONS GC01011(rev2) INTRODUCTION Thank you for purchasing this CLARKE Log Horse. Before attempting to operate the product,
More informationInstallation Instructions Factory Style Bow Kit
INSTALLATION TIME Installation Instructions Factory Style Bow Kit SKILL LEVEL Vehicle Application: Jeep Wrangler JK 2 Door 2007 Current Part Number: 55000 Compatible with original equipment soft tops,
More informationMIRAGE-X / BELLA. Shower Door Installation Instructions
MIRAGE-X / BELLA Shower Door Installation Instructions IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical
More informationSHOWER SCREEN INSTALLATION GUIDE WET ROOMS MADE EASY
SHOWER SCREEN INSTALLATION GUIDE WET ROOMS MADE EASY IMPORTANT INFORMATION TOOLS & PARTS REQUIRED Please read these instructions carefully before starting installation and keep for future reference. Remove
More informationENVIRONMENTAL. Operating Temperature: -40ºC to +125ºC 0XX. Wire Gauge Size. Code Accepted Wire Cap Code Wire Gauge Insulation Pages 6-7
The 917X series of surface mount Displacement Connectors (IDC) were developed to meet the harsh automotive and industrial market applications for connecting individual wires directly to a PCB ranging from
More informationGeneral-Purpose Photoelectric Sensor
General-Purpose Photoelectric Sensor Wide Selection of High Performance Small DC Sensors Offers Longer Sensing Distances Fast 0. msec response time for high-speed sensing Extended sensing distances up
More informationRadiant 3000F Video Light (Cat. No. 6052)
Fantasea Line Radiant 3000F Video Light (Cat. No. 6052) Instruction Manual 1 TABLE OF CONTENTS TABLE OF CONTENTS... 2 DISCLAIMER... 3 INTRODUCTION... 3 GENERAL INFORMATION... 3 SPECIFICATIONS... 4 INCLUDED
More informationRIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.
User s Guide RP5600 Passive Probe July 2010 RIGOL Technologies, Inc. Guaranty and Declaration Copyright 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is a registered trademark
More informationOperating Instructions and Parts Manual Hydraulic Shop Presses Models HP-5A/15A/35A
Operating Instructions and Parts Manual Hydraulic Shop Presses Models HP-5A/15A/35A Model HP-35A shown JET 427 New Sanford Road LaVergne, Tennessee 37086 Part No. M-331406 Ph.: 800-274-6848 Revision C1
More informationExercise Heart Rate Sensor
Instruction Manual 012-12232A *012-12232* PS-2129A Strap Hook Strap Adjuster Red LED Electrodes (not shown) Sensor Connector Snaps Strap Equipment Included Polar WearLink Set (M-XXL) Also Required PASCO
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS AXIS 7 x 8 CURVED SHOWER DOOR MODEL: AM88A00 SERIES Thank you for selecting American Standard the benchmark of fine quality for over 00 years. To ensure this product is installed
More informationENIGMA AIR ENCLOSURE
ENIGMA AIR ENCLOSURE SHOWER ENCLOSURE INSTALLATION INSTRUCTION IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical
More informationLine-Following Robot
1 Line-Following Robot Printed Circuit Board Assembly Jeffrey La Favre October 5, 2014 After you have learned to solder, you are ready to start the assembly of your robot. The assembly will be divided
More information