RD1000 Ground Probing Radar

Size: px
Start display at page:

Download "RD1000 Ground Probing Radar"

Transcription

1 RD1000 Ground Probing Radar

2 CONTENTS Product Introduction Product Features Competitor Analysis Customers Models, Pricing & Availability Promotional Material Practical Demonstration What to do now Summary

3 CONTENTS Product Introduction Product Features Competitor Analysis Customers Models, Pricing & Availability Promotional Material Practical Demonstration What to do now Summary

4 Product Introduction What is RD1000? A new product using Radar technology and a technique known as GPR (Ground Probing Radar) Provides a real time display of all buried services (pipes and cables) including metallic and non-metallic (plastic)

5 Product Introduction What is RD1000? A portable unit on four wheels that can be easily stowed in a vehicle Provides an excellent compliment to our existing range of cable and pipe locators RD1000 is a new product and does not replace any existing Radiodetection product - it s all incremental sales!

6 Product Introduction Why have we introduced RD1000? Ground Probing Radar has been increasing in popularity with our customers in recent years Many of our customers (Utility companies) are purchasing both cable and pipe locators and GPR products. A major objection to using GPR products is the price It is a relatively new technology and Radiodetection wants to be involved in its future development

7 CONTENTS Product Introduction Product Features Competitor Analysis Customers Models, Pricing & Availability Promotional Material Practical Demonstration What to do now Summary

8 Features of GPR Arches occur because GPR energy does not radiate as a pencil-thin beam but more like a 3D cone. The GPR sensor sees the pipe before and after going over top of it and forms an arch-shaped response on the image

9 Features of GPR If the target is a long, linear object like a pipe or cable, it is important that the target arch used for the soil type calibration be produced by crossing the target at a 90 degree angle. The depth estimation of a target will be incorrect if the soil type calibration is done on a target arch produced at an oblique angle (smaller that 90 degrees).

10 High performance radar and processing system delivering cutting edge performance Tough molded plastic shell 1.Emission approved for all major jurisdictions db bandwidth MHz 3.Weight < 5 kg 4.Power required < 8 W 5.Size 630 x 410 x 230 (mm) Display connector Odometer connector Battery connector High wear resistant skid plate

11 Simple straightforward operation Removable flash memory card Rugged aluminum extrusion housing Optimal sunlight visible screen Upgradable embedded software Low power <5W Water proof enclosure System total power management Simple intuitive user interface Tough membrane keypad Image recording option

12 Simple straightforward operation Upgrade firmware from flash 1.Simple user interface 2.Selectable depth range to 8m 3.Signal enhanced filtering 4.Symbolic or selected language menus 5.Interactive target location 6.Target depth estimation with optimization for soil type

13 Simple straightforward operation Press the Scan or button to start scanning. Language: Select the language for the menus. Current options are English or Icons. Units: Units for the Position Axis, Depth Axis and Depth Indicator can be either Meters or Feet. Lines: Select whether Depth Lines are ON or OFF. The horizontal lines appear on the image to assist with determining the depth of targets. Date: Opens the Date Screen to change the current date. Images are saved with this date. Time: Opens the Time Screen to change the current date. Images are saved with this time. Power Off: Opens a sub-menu to confirm powering off the system. There is also an option to restore the system to factory default settings.

14 Simple straightforward operation SCANNING SCREEN As the Cart is pushed forward a cross-sectional image of the ground scrolls onto the screen from the right to left. The position is displayed on the horizontal axis at the top while the depth is displayed on the vertical axis. The position and depth axes units are meters or feet. Approximately 16 meters or 50 feet of data is displayed on one screen. If the survey line exceeds this distance the image will scroll off the left side of the screen. To save the current screen image to file, press the Camera button on the Display Unit.

15 Simple straightforward operation SCANNING SCREEN Pressing any of the buttons on the Display Unit marked 1 to 8 while scanning adds a numbered marker at the current position. Pressing the Pause button opens the Image Settings Screen to change the current Color Palette, Depth, Filter and Gain.

16 Simple straightforward operation IMAGE SETTING SCREEN Pressing the Pause button opens the Image Settings Screen to change the current Color Palette, Depth, Filter and Gain.

17 Simple straightforward operation IMAGE SETTING SCREEN Color: GPR images are displayed in colors corresponding to a color palette. In general stronger GPR signals appear in stronger colors

18 Simple straightforward operation IMAGE SETTING SCREEN Gain: Since GPR signals are absorbed by the material being scanned, deeper targets have weaker signals. Gain acts like an audio volume control, amplifying the signals and making deeper targets appear stronger in the image. The Gain varies from 1 to 9 with 1 being no gain and 9 being the maximum gain.

19 Simple straightforward operation IMAGE SETTING SCREEN Filter: The filter has the effect of removing flat-lying reflections in the image and enhancing the dipping reflections and arches usually caused by targets.

20 Simple straightforward operation IMAGE SETTING SCREEN Depth: The depth setting is an estimate of the total depth displayed on the Scanning Screen based on the current Soil Type setting. The depth setting ranges from 1 to 8 meters. The system always collects data to a depth of approximately 8 meters but the Depth setting determines how much of the data is displayed on the screen. It is possible to scan with a Depth setting of, say 2 meters, pause scanning and then increase the depth setting to re-display the image to look for deeper targets. Return: Exits the Scanning and Image Settings Screens and returns to the Systems Settings Screen.

21 Simple straightforward operation LOCATING SCREEN The Locating Screen is accessed by stopping and pulling the cart backwards while scanning. Cursor: The Cursor is the moving cross-hairs that consists of 3 parts: Position Indicator vertical cross-hair is tied to the odometer and corresponds to the location at the center of the GPR sensor. As the cart is pulled backwards, the Position Indicator moves to indicate the current location of the cart in the image. Depth Indicator horizontal cross-hair found at the peak of the soil type indicator arch indicating the depth. Indicator Arch idealized representation of typical pipe-like target response observed on GPR image. The width of the arch is controlled by soil type setting. The soil type setting is changed using the Arch buttons. Increasing the soil type makes the indicator arch wider while decreasing the soil type makes it narrower.

22 Simple straightforward operation LOCATING SCREEN SOIL TYPE CALIBRATION - matching a target arch 1) With a target arch visible on the image, back the cart up until the Position Indicator is centered on the target arch in the GPR image; preferably one with long tails because this provides the most accurate soil type calibration. 2) Use the Up and Down Arrows to move the Indicator Arch shallower or deeper in the GPR image, respectively, until it lies overtop of the target arch. 3) Use the Wide and Narrow Arch buttons to change the shape of the Indicator Arch to match the shape of the Target Arch on the GPR image. The Wider Arch button increases the Soil Type while the Narrow Arch button decreases it.

23 Simple straightforward operation LOCATING SCREEN SOIL TYPE CALIBRATION - matching a target arch 4) The Soil Type value is displayed above the menu. Press the Save button to save this value and use it for estimating the depth of targets while scanning in the area.

24 Tough Durable Assembly and Ergonomic Design Tough, non-metallic fiberglass construction Quick release display unit Integrated odometer Quick release removable handle

25 Portable - Easy to Transport 1.Ships in one container 2.All up weight < 23 kg 3.Assembly on site in < 2 minutes

26 Modular Assembly Makes Service and Repair Quick and Cost Effective Display unit Cart Cabling Power Sensor Odometer

27 Optical encoded rotation sensor detects motion forward and reverse 1 mm resolution Tough short length cables with standard connectors Optional spares kit available in case of accidental damage in the field

28 Power Quick replace battery pack Tough case with quick release connector 1.Battery -9 Ah standard 2.Supply voltage 12V 3.Proven industry standard lead-acid gel cells 4.Standard battery charger 5.Weight < 4 kg

UTILITY LOCATING EQUIPMENT

UTILITY LOCATING EQUIPMENT RIDGID SEEKTECH LOCATING RECEIVERS RIDGID locating receivers feature an easy-to-use visual mapping display that allows you to locate utility lines and sondes/beacons with confidence. Use with a SeeSnake

More information

SUBSURFACE INSTRUMENTS, INC. AML PRO & AML+ PRODUCT GUIDE

SUBSURFACE INSTRUMENTS, INC. AML PRO & AML+ PRODUCT GUIDE SUBSURFACE INSTRUMENTS, INC. AML PRO & AML+ PRODUCT GUIDE Advanced Underground PVC Pipe Detection Patented Technology Advanced PVC & PE Pipe Detection FCC, IC & EU/CE Approved www.ssilocators.com INTRODUCING

More information

Operators Manual For Spectrum Analyser SA97

Operators Manual For Spectrum Analyser SA97 Included with: Padded nylon carrying case. Mains battery charger. Car cigarette lighter charger lead. Quick reference card. RS232 interface socket. Operators Manual For Spectrum Analyser SA97 Features

More information

Mag 3/6 System. Manual.

Mag 3/6 System. Manual. Mag 3/6 System Manual www.undergroundmagnetics.com 1: Introduction....1 1 2: Caution.... 2 2 3: FCC Compliance Statement.. 3 4: Tips for Reading this Manual....3 4 5: Preface....4 5 6: System Highlights....6

More information

RD Portable Ground Penetrating Radar System

RD Portable Ground Penetrating Radar System OPERATION MANUAL RD1000 + Portable Ground Penetrating Radar System 90/RD1K+-OPMAN-ENG/01 ISSUE 1 04/2014 Read and understand this manual prior to operating the system Preface Before you begin Thank you

More information

Easy Locator HDR. Terraplus Inc. 52 West Beaver Cr. Rd. #12, Richmond Hill, ON. Canada L4B 1L9. Utility Locating System

Easy Locator HDR. Terraplus Inc. 52 West Beaver Cr. Rd. #12, Richmond Hill, ON. Canada L4B 1L9. Utility Locating System Utility Locating System Easy Locator HDR Terraplus is pleased to introduce the Easy Locator HDR (High Dynamic Range). The Easy Locator HDR is faster, easier to use, more powerful, delivers cleaner data

More information

NEULOG PHOTO GATE LOGGER SENSOR GUIDE

NEULOG PHOTO GATE LOGGER SENSOR GUIDE NeuLog photo gate logger sensor NUL-209 Part# NL-2090 The NeuLog photo gate sensor can be used for any science experiment which involves taking accurate velocity and/or acceleration measurements especially

More information

NEULOG PHOTO GATE LOGGER SENSOR GUIDE

NEULOG PHOTO GATE LOGGER SENSOR GUIDE NeuLog photo gate logger sensor NUL-209 The NeuLog photo gate sensor can be used for any science experiment which involves taking accurate velocity and/or acceleration measurements especially in the field

More information

E600 Series II Portable, Tactical Weather Radar System

E600 Series II Portable, Tactical Weather Radar System E600 Series II Portable, Tactical Weather Radar System E600 Tactical Weather Radar System Used as a tactical unit by the U.S. Military, the E600 Series II is the most portable weather radar system on

More information

AA-35 ZOOM. RigExpert. User s manual. Antenna and cable analyzer

AA-35 ZOOM. RigExpert. User s manual. Antenna and cable analyzer AA-35 ZOOM Antenna and cable analyzer RigExpert User s manual . Table of contents Introduction Operating the AA-35 ZOOM First time use Main menu Multifunctional keys Connecting to your antenna SWR chart

More information

Four Carrier Signal Generator Operation Manual

Four Carrier Signal Generator Operation Manual ACE 5400 Four Carrier Signal Generator Operation Manual Table of Contents 1. Features...2 1.1. Specifications...3 1.2. Connections...3 1.3. Controls and Connections...4 1.4. Keypad...4 2. Operating Modes...5

More information

1: Introduction : Caution : Tips for Reading this Manual : Preface : System Highlights : Receiver

1: Introduction : Caution : Tips for Reading this Manual : Preface : System Highlights : Receiver 1: Introduction....1 1 2: Caution.... 2 2 3: Tips for Reading this Manual....3 3 4: Preface....4 4 5: System Highlights....6 6 6: Receiver..7 7 6.1: Specifications......7 7 6.2: Receiver Operation... 7

More information

Experiment P55: Light Intensity vs. Position (Light Sensor, Motion Sensor)

Experiment P55: Light Intensity vs. Position (Light Sensor, Motion Sensor) PASCO scientific Vol. 2 Physics Lab Manual: P55-1 Experiment P55: (Light Sensor, Motion Sensor) Concept Time SW Interface Macintosh file Windows file illuminance 30 m 500/700 P55 Light vs. Position P55_LTVM.SWS

More information

IT-24 RigExpert. 2.4 GHz ISM Band Universal Tester. User s manual

IT-24 RigExpert. 2.4 GHz ISM Band Universal Tester. User s manual IT-24 RigExpert 2.4 GHz ISM Band Universal Tester User s manual Table of contents 1. Description 2. Specifications 3. Using the tester 3.1. Before you start 3.2. Turning the tester on and off 3.3. Main

More information

Easy Locator. Operator s Manual. Version

Easy Locator. Operator s Manual. Version Easy Locator Operator s Manual Version 2.6 19-001011 Table of Contents 1 Introduction 3 1.1 Unpacking and Inspection 4 1.2 Repacking and Shipping 4 1.3 Important information regarding the use of this GPR

More information

RF Explorer. User Manual. RF Explorer User Manual v Page 1 of 13. Updated to firmware v1.05. Edition date: 2011/Mar/01.

RF Explorer. User Manual. RF Explorer User Manual v Page 1 of 13. Updated to firmware v1.05. Edition date: 2011/Mar/01. RF Explorer User Manual v1.05 - Page 1 of 13 RF Explorer User Manual Updated to firmware v1.05 Edition date: 2011/Mar/01 www.rf-explorer.com Please consider the environment before printing this manual.

More information

DITCH WITCH ELECTRONIC GUIDANCE EQUIPMENT

DITCH WITCH ELECTRONIC GUIDANCE EQUIPMENT DITCH WITCH ELECTRONIC GUIDANCE EQUIPMENT guesswork is officially dead. Ditch Witch. DITCH WITCH 752 TRACKER, 752 DISPLAY Location, depth, roll angle, pitch, beacon temperature, battery status the Ditch

More information

NeuLog photo gate logger sensor NUL-209

NeuLog photo gate logger sensor NUL-209 NeuLog photo gate logger sensor NUL-209 The NeuLog photo gate sensor can be used for any science experiment or activity which involves taking accurate velocity and/or acceleration measurements especially

More information

use, more powerful, delivers cleaner data with more detail and up to 20% better penetration depth than comparable systems.

use, more powerful, delivers cleaner data with more detail and up to 20% better penetration depth than comparable systems. Utility Locating System Easy Locator HDR Pro Terraplus is pleased to introduce the Easy Locator HDR (High Dynamic Range) Pro. The Easy Locator HDR Pro is faster, easier to use, more powerful, delivers

More information

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual USL300 SNOW DEPTH SENSOR Revision 1.1.2 User Manual 1 Table of Contents 1. Introduction... 3 2. Operation... 3 2.1. Electrostatic Transducer... 4 2.2. SL300 Analog Board... 4 2.3. SL300 Digital Circuit

More information

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions Wireless Temperature and Humidity Overview and Indentification The Wireless Temperature and Humidity measures the room temperature and Relative Humidity and transmits the data at 418MHz or 433MHz RF to

More information

MALÅ Easy Locator. Operating Manual v

MALÅ Easy Locator. Operating Manual v MALÅ Easy Locator Operating Manual v. 2.0 19-001011 Table of Contents 1 Introduction 3 1.1 Unpacking and Inspection 4 1.2 Repacking and Shipping 4 1.3 Important information regarding the use of this GPR

More information

TV SIGNAL LEVEL METER USER MANUAL

TV SIGNAL LEVEL METER USER MANUAL TV SIGNAL LEVEL METER USER MANUAL - 0 - 1. Overview (1) (1) RF input (2) (3) A D E B C (2) Speaker (3) LCD display (4) Charger indicator (5) RS232 communication port (6) DC-IN port F G A. The battery icon

More information

Quiver User Guide. Xcor-QUG-v /13/12

Quiver User Guide. Xcor-QUG-v /13/12 Quiver User Guide Xcor-QUG-v.3.0.4 8/13/12 This document details the full features and functionality of Quiver. Included is information on the various modes of operation and instruction on how to best

More information

LSC Radio User Guide Information and Guidelines

LSC Radio User Guide Information and Guidelines LSC Radio User Guide Information and Guidelines The following user guide applies to both the Motorola VL50 and CLS1410 Radio s. Below are guidelines established for usage. 1) Radios and headsets are to

More information

Opera Duo. Opera Duo. GeoRadar Division. a first class underground survey

Opera Duo. Opera Duo. GeoRadar Division. a first class underground survey a first class underground survey Opera Duo Competitive advantages Designed around you A large, comfortable handle to make pushing an pulling easier, large wheels for better control and a balanced weight

More information

Operating Manual MRL-101

Operating Manual MRL-101 Operating Manual MRL-101 Maintenance and Safety While the instrument is operating, be careful not to expose your eyes to the laser beam. Direct exposure to a laser beam for a long time may be hazardous

More information

Pipe Laser Model No Instruction Manual

Pipe Laser Model No Instruction Manual Pipe Laser Model No. 40-6690 Instruction Manual Congratulations on your choice of this Pipe Laser. We suggest you read this instruction manual thoroughly before using the pipe laser. Save this instruction

More information

PHYSICS 220 LAB #1: ONE-DIMENSIONAL MOTION

PHYSICS 220 LAB #1: ONE-DIMENSIONAL MOTION /53 pts Name: Partners: PHYSICS 22 LAB #1: ONE-DIMENSIONAL MOTION OBJECTIVES 1. To learn about three complementary ways to describe motion in one dimension words, graphs, and vector diagrams. 2. To acquire

More information

Model BiConiLog Antenna. User Manual

Model BiConiLog Antenna. User Manual Model 3149 BiConiLog Antenna User Manual ETS-Lindgren Inc. reserves the right to make changes to any products herein to improve functioning or design. Although the information in this document has been

More information

Operator Manual 1.4 FRACSIM MINI

Operator Manual 1.4 FRACSIM MINI FracSim Meters FracSim Meters was founded with the intention of providing specifically designed tools for the well service industry. Our goal is to provide quality tools with a robust design to meet the

More information

USER GUIDE. Mini InfraRed Thermometer with Laser Pointer MODEL 42500

USER GUIDE. Mini InfraRed Thermometer with Laser Pointer MODEL 42500 USER GUIDE Mini InfraRed Thermometer with Laser Pointer MODEL 42500 Introduction Congratulations on your purchase of the Model 42500 IR Thermometer. This thermometer makes noncontact (infrared) temperature

More information

A510S Operation Manual

A510S Operation Manual A510S Operation Manual REV 1.1 1 Table of Contents 1 General Information 1-1 Description 1-2 Potential Operational Hazards 1-3 Technical Specifications 1-4 Instrument Overview 1-5 Function Summary 2 How

More information

G703. Installation instructions. residential gate opener for sliding gates. remote control openers security at your fingertips

G703. Installation instructions. residential gate opener for sliding gates. remote control openers security at your fingertips remote control openers security at your fingertips G703 residential gate opener for sliding gates Installation instructions Toll free helpline Please have your serial number and model name available before

More information

Agilent EPM Series Power Meters

Agilent EPM Series Power Meters Agilent EPM Series Power Meters The standard just got better! What s new? Fast measurement speeds (up to 200 readings per second) Wide dynamic range sensors (-70 dbm to +44 dbm), sensor dependent Calibration

More information

cable and pipe locators RD Utility cable and pipe locator

cable and pipe locators RD Utility cable and pipe locator cable and pipe locators RD7000 + Utility cable and pipe locator RD7000 + delivering fast, accurate, reliable and repeatable locate information for all utilities. Visually follow the target cable or pipe

More information

Opera Duo. GeoRadar Division

Opera Duo. GeoRadar Division Utilities Detection and Mapping Opera Duo: real-time detection of pipes RIS MF Hi-Mod: Utilities mapping on all zones All rights reserved to IDS 2 Utilities Detection and Mapping Stream: massive arrays

More information

Suitable firmware can be found on Anritsu's web site under the instrument library listings.

Suitable firmware can be found on Anritsu's web site under the instrument library listings. General Caution Please use a USB Memory Stick for firmware updates. Suitable firmware can be found on Anritsu's web site under the instrument library listings. If your existing firmware is older than v1.19,

More information

Optical Pumping Control Unit

Optical Pumping Control Unit (Advanced) Experimental Physics V85.0112/G85.2075 Optical Pumping Control Unit Fall, 2012 10/16/2012 Introduction This document is gives an overview of the optical pumping control unit. Magnetic Fields

More information

YRS01 York Reference Source

YRS01 York Reference Source York Reference Source York Reference Source The YRS01 is a multi-mode reference source capable of producing a broadband noise or comb output up to 1GHz. Selectable noise or comb output - Flexibility across

More information

rino 600 series quick start manual

rino 600 series quick start manual rino 600 series quick start manual Getting Started Keys warning See the Important Safety and Product Information guide in the product box for product warnings and other important information. When using

More information

Home Automation, Inc. Model 12A00. Wireless Receiver. Installation Manual

Home Automation, Inc. Model 12A00. Wireless Receiver. Installation Manual Home Automation, Inc. Model 12A00 Wireless Receiver Installation Manual Document Number 12I00 Rev D August, 2002 CONTENTS DESCRIPTION...1 COMPATIBLE TRANSMITTERS...1 INSTALLATION...2 OPERATION...3 SETUP

More information

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE: Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:

More information

4. BASIC OPERATION AND DESCRIPTION

4. BASIC OPERATION AND DESCRIPTION 3. FEATURES Rugged high-impact plastic enclosure with aluminum sensor pole Powerful magnetic speaker with waterproof Mylar cone Lightweight, comfortably balanced for easy handling Easy view LCD display

More information

Eddy current flaw detector «Eddycon C»

Eddy current flaw detector «Eddycon C» ULTRACON-SERVICE LLC Eddy current flaw detector «Eddycon C» Quick start guide CONTENTS P. 1 CONTROLLERS OF EDDYCON C FLAW DETECTOR... 3 2 SETTINGS OF «TEST» MENU... 5 3 INSTRUCTIONS FOR USE... 8 3.1 THRESHOLD

More information

STRIKER Series. Owner s Manual

STRIKER Series. Owner s Manual STRIKER Series Owner s Manual Table of Contents Introduction...1 Device Keys... 1 Contacting Garmin Product Support... 1 Selecting the Transducer Type... 1 Zooming on the STRIKER 4... 1 Panning on the

More information

MAGNETIC FIELD METER Operator s Manual

MAGNETIC FIELD METER Operator s Manual Edition 3.1 2009-09-03 MAGNETIC FIELD METER 2000 Operator s Manual The MFM 2000 is a professional magnetic field instrument To make the best use of the instrument we recommend that you read this manual

More information

RECTANGULAR RAPID FLASHING BEACON WITH LARGE LED ARRAYS TAPCO RRFB-XL : Solar Powered; Extra Large LED Arrays, Wirelessly Synchronized

RECTANGULAR RAPID FLASHING BEACON WITH LARGE LED ARRAYS TAPCO RRFB-XL : Solar Powered; Extra Large LED Arrays, Wirelessly Synchronized RECTANGULAR RAPID FLASHING BEACON WITH LARGE LED ARRAYS TAPCO RRFB-XL : Solar Powered; Extra Large LED Arrays, Wirelessly Synchronized 1.0 Description The Manufacturer shall provide a Rectangular Rapid

More information

PRODUCT MANUAL. AGD Systems Limited 2016 Doc. Ref. 932 PM ISS3 ISO ISO 9001 Registered Quality Management. Registered Environmental Management

PRODUCT MANUAL. AGD Systems Limited 2016 Doc. Ref. 932 PM ISS3 ISO ISO 9001 Registered Quality Management. Registered Environmental Management ISO 14001 PRODUCT MANUAL ISO 9001 Registered Quality Management 015 Registered Environmental Management 015 AGD Systems Limited 2016 Doc. Ref. 932 PM ISS3 TABLE OF CONTENTS INTRODUCTION Product & technology

More information

Instruction Manual. Magnetic Locator

Instruction Manual. Magnetic Locator Instruction Manual Magnetic Locator Made in USA P: (304) 725-1050 l www.schonstedt.com l info@schonstedt.com 100 Edmond Road, Kearneysville, WV 25430 Important Notice Schonstedt believes the statements

More information

NEULOG CALCIUM ION LOGGER SENSOR GUIDE

NEULOG CALCIUM ION LOGGER SENSOR GUIDE NeuLog calcium logger sensor NUL-238 The NeuLog calcium ion sensor can be used for any science experiment or activity which can utilize calcium concentration readings such as in the fields of Environmental

More information

SeekTech SR-60 SeekTech SR-20 NaviTrack Scout

SeekTech SR-60 SeekTech SR-20 NaviTrack Scout Locating Equipment RIDGID Receivers RIDGID locating receivers feature an easy to use visual mapping display that allows you to locate utility lines and sondes/ beacons with confidence. Use with a SeeSnake

More information

One connected to the trainer port, MagTrack should be configured, please see Configuration section on this manual.

One connected to the trainer port, MagTrack should be configured, please see Configuration section on this manual. MagTrack R Head Tracking System Instruction Manual ABSTRACT MagTrack R is a magnetic Head Track system intended to be used for FPV flight. The system measures the components of the magnetic earth field

More information

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.2

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.2 Typical Applications Typical Applications Pipe & cable locator transmitter Transmitting active signals for the location of buried pipes and cables Construction High impact ABS Transmitter Assembly Weight

More information

----STAR S86 GPS Receiver. User Guide. SOUTH CO., Ltd.

----STAR S86 GPS Receiver. User Guide. SOUTH CO., Ltd. ----STAR S86 GPS Receiver User Guide SOUTH CO., Ltd. www.southsurveying.com Sales@SOUTHsurveying.com 2 CONTENTS Chapter 1 Introduction... 1 STAR S86 GPS - System Summary... 1 Technical Specification...

More information

The Standard for over 40 Years

The Standard for over 40 Years Light Measurement The Standard for over 40 Years Introduction LI-COR radiation sensors measure the flux of radiant energy the energy that drives plant growth, warms the earth, and lights our world. The

More information

Driveway Alarm INSTALLATION MANUAL

Driveway Alarm INSTALLATION MANUAL WIRELESS ACCESS CONTROLS Driveway Alarm INSTALLATION MANUAL Mounting post Transmitter Receiver Transformer Sensor Kit Includes: Transmitter Module Sensor Receiver Transformer Mounting post (3 pieces) Installation

More information

Bipedinno. 12-DOF Waist-high Robot

Bipedinno. 12-DOF Waist-high Robot Bipedinno 12-DOF Waist-high Robot Instruction Manual Version 1.18 Trademark Innovati,, and BASIC Commander, are registered trademarks of Innovati Inc. InnoBASIC and cmdbus are trademarks of Innovati Inc.

More information

Experiment P24: Motor Efficiency (Photogate, Power Amplifier, Voltage Sensor)

Experiment P24: Motor Efficiency (Photogate, Power Amplifier, Voltage Sensor) PASCO scientific Physics Lab Manual: P24-1 Experiment P24: Motor Efficiency (Photogate, Power Amplifier, Voltage Sensor) Concept Time SW Interface Macintosh File Windows File energy 30 m 700 P24 Motor

More information

L O C A T O R G P R. Introducing the. Radarteam. Ground Probing Radar/Antenna system with Rugged PC and Cart ü

L O C A T O R G P R. Introducing the. Radarteam. Ground Probing Radar/Antenna system with Rugged PC and Cart ü Introducing the L O C A T O R G P R Ground Probing Radar/Antenna system with Rugged PC and Cart ü Fully integrated system. Multi Frequency operation: 100-900 MHz ü Air/Ground Coupled operation. Multiple

More information

DANGER POWER UP. 1. Close saw hood 2. Reset safety kill line 3. Reset saw cabinet E-stop 4. Power up. Quick Reference Card TigerSaw

DANGER POWER UP. 1. Close saw hood 2. Reset safety kill line 3. Reset saw cabinet E-stop 4. Power up. Quick Reference Card TigerSaw Quick Reference Card TigerSaw DANGER This machine can start, move, and stop automatically. Keep hands and loose clothing clear of moving parts while operating. Moving parts can crush and cut. When used

More information

Operation Manual for D2366 GPRS Radio Test Set

Operation Manual for D2366 GPRS Radio Test Set Operation Manual for D2366 GPRS Radio Test Set Dycon Ltd Tel: +44 (0)1443 471 060 Fax: +44 (0)1443 479 374 Cwm Cynon Business Park Mountain Ash CF45 4ER - UK www.dyconsecurity.com TABLE OF CONTENTS Product

More information

UltraTEV Locator Portable Partial Discharge (PD) investigation system.

UltraTEV Locator Portable Partial Discharge (PD) investigation system. UltraTEV Locator Portable Partial Discharge (PD) investigation system Locates, measures and records PD activity in all substation assets including cables www.eatechnologyusa.com Benefits Locating and measuring

More information

I N N O V A T I N G U N D E R G R O U N D L O C A T I N G

I N N O V A T I N G U N D E R G R O U N D L O C A T I N G Model CI-5120 CI-5120 RECEIVER SPECIFICATIONS RECEIVER Gun-Type Housing Three Position Swivel Antenna Signal Adjust Control Audio/Mute Switch Lighted Tracking Display Hi-Impact Plastic Carrying Case (Optional)

More information

STANDARD OPERATING PROCEDURES SOP:: 2057 PAGE: 1 of 6 REV: 0.0 DATE: 07/11/03

STANDARD OPERATING PROCEDURES SOP:: 2057 PAGE: 1 of 6 REV: 0.0 DATE: 07/11/03 PAGE: 1 of 6 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY CONTENTS 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING, AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS

More information

BIM - ARCHITECTUAL IMPORTING A SCANNED PLAN

BIM - ARCHITECTUAL IMPORTING A SCANNED PLAN BIM - ARCHITECTUAL IMPORTING A SCANNED PLAN INTRODUCTION In this section, we will demonstrate importing a plan created in another application. One of the most common starting points for a project is from

More information

GE AMX 4+ Portable X-Ray

GE AMX 4+ Portable X-Ray GE AMX 4+ Portable X-Ray Typical Manufacturer s Picture GE Healthcare s AMX-4+ analog X-ray system provides high-performance in a compact, easy-to-maneuver package. The rotating arm and tube simplify positioning

More information

ABM International, Inc. Navigator Assembly Manual

ABM International, Inc. Navigator Assembly Manual ABM International, Inc. 1 1.0: Parts List Tablet (Qty. 1) Tablet mount (Qty. 1) NOTE: Mount may appear and operate different then image below Control Box (Qty. 1) Motor Power Supply (Qty. 1) 2 X-axis motor

More information

UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related

UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related UltraTEV Locator Portable PD (Partial Discharge) investigation system Locates, measures and records PD activity in all substation assets including cables benefits Locating and measuring PD activity to

More information

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER DESCRIPTION The UltraFlo UFDD Clamp-On Ultrasonic Flow Meter is the ideal flow meter with accurate, easy-to-use, easy-to-install digital doppler technology.

More information

echo 100 and echo 150 owner s manual

echo 100 and echo 150 owner s manual echo 100 and echo 150 owner s manual Introduction Introduction Warning See the Important Safety and Product Information guide in the product box for product warnings and other important information. This

More information

PosiTector 200. Ultrasonic Coating Thickness Gage. Standard and Advanced. INSTRUCTION MANUAL v Simple. Durable. Accurate.

PosiTector 200. Ultrasonic Coating Thickness Gage. Standard and Advanced. INSTRUCTION MANUAL v Simple. Durable. Accurate. PosiTector 200 INSTRUCTION MANUAL v. 2.0 Ultrasonic Coating Thickness Gage Standard and Advanced Simple. Durable. Accurate. Introduction The PosiTector 200 is a hand-held Coating Thickness Gage that uses

More information

Laser LA-4P. Operating instructions

Laser LA-4P. Operating instructions Laser LA-4P GB Operating instructions A 1 2 3a 5 3c 3b 3a 4 11 11 6 10 7 14a 14b 14c 12 9 8 B C 2. 1. D E F Ø 50mm - 115 mm Ø 2-4,5 G I K s > 6m > 20ft L M N P1 Q O 13 P2 GB Operating instructions The

More information

DITCH WITCH LOCATORS

DITCH WITCH LOCATORS DITCH WITCH LOCATORS YOUR WINDOW TO THE UNDERGROUND. DITCH WITCH 950R/T and 970T Pipe and Cable Locator System Like real estate, underground construction is all about location, location, location. The

More information

AK-18G Antenna Kit Operation Manual

AK-18G Antenna Kit Operation Manual AK-18G Antenna Kit Operation Manual 1 TABLE OF CONTENTS WARRANTY 3 INTRODUCTION 4 GENERAL INFORMATION 5 OPTIONAL EQUIPMENT 8 FORMULAS 9 MAINTENANCE 10 2 WARRANTY INFORMATION A.H. Systems Inc., warrants

More information

QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS

QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS 1.0 DESIGNATIONS T2 AND X2 1. Removable Reflector, two positions Normal and Wide angle. 2. Flash-tube 2A. Modeling Lamp (for Model X2 only) 3. Bounce Head,

More information

General purpose Signal generation and analysis. Well-equipped for field and lab the R&S Spectrum Rider

General purpose Signal generation and analysis. Well-equipped for field and lab the R&S Spectrum Rider General purpose Signal generation and analysis Well-equipped for field and lab the R&S Spectrum Rider 32 The new R&S Spectrum Rider makes spectrum analysis in the field and lab easier, faster and more

More information

USER MANUAL ENGLISH 2985-SX BANKNOTE COUNTER

USER MANUAL ENGLISH 2985-SX BANKNOTE COUNTER USER MANUAL ENGLISH 2985-SX BANKNOTE COUNTER INTRODUCTION ENGLISH Thank you for purchasing Safescan 2985-SX banknote counter. For proper use and maintenance, we advise to read this user manual carefully.

More information

DIVERSE MAGMETER MF500M+ USER MANUAL. Contents INTRODUCTION FIRST TIME - QUICK START OPERATION OPERATION - OPTIONS MAGNETITE METER

DIVERSE MAGMETER MF500M+ USER MANUAL. Contents INTRODUCTION FIRST TIME - QUICK START OPERATION OPERATION - OPTIONS MAGNETITE METER Contents DIVERSE MAGMETER MF500M+ INTRODUCTION FIRST TIME - QUICK START OPERATION OPERATION - OPTIONS MAGNETITE METER CALIBRATION AND PIPE OCCLUSION MEASUREMENT TECHNIQUE SPECIFICATION USER MANUAL LIABILITY

More information

Mo d e l Ma g h o r n Ma g n e t ic Lo c a t o r

Mo d e l Ma g h o r n Ma g n e t ic Lo c a t o r Mo d e l 4 5 0 Ma g h o r n Ma g n e t ic Lo c a t o r Us e r s Ma n u a l Manufactured Exclusively By: Utility Tool Company, Inc. 2900 Commerce Boulevard Birmingham, Alabama 35210 205-956-3710 User s

More information

PT-1. Pipe Tracker OPERATION MANUAL 1010 JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA USA

PT-1. Pipe Tracker OPERATION MANUAL 1010 JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA USA Pipe Tracker OPERATION MANUAL 1010 JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA 02718 USA (508) 822-7330; (800) 822-4744; FAX (508) 880-8949 Email: jwfishers@aol.com WEB: www.jwfishers.com MAINTENANCE

More information

Appearance of device and accessories may vary.

Appearance of device and accessories may vary. Mobile 4G Smart Technology Signal Booster Contents: How it Works.... 1 Before Getting Started.... 2 Quick Installation Overview.... 2 Installing the Outside Antenna.... 2 Installing the Low-Profile Antenna....

More information

Canopy Interception and Leaf Area Index

Canopy Interception and Leaf Area Index Canopy Interception and Leaf Area Index metergroup.com/environment/products/accupar-lp-80-leaf-area-index/ Accurate canopy analysis in real time ACCUPAR LP-80 Measuring canopy density can be problematic

More information

Scanner Basic Configuration Part-No. 21R

Scanner Basic Configuration Part-No. 21R Scanner Basic Configuration Part-No. 21R09-00-101-00 3D Laser Scanner Part-No. 21R09-00-001-00 laser transmitter & receiver front end motorized mirror scanning mechanism signal processing electronics with

More information

GPR SYSTEM USER GUIDE AND TROUBLESHOOTING GUIDE

GPR SYSTEM USER GUIDE AND TROUBLESHOOTING GUIDE GPR SYSTEM USER GUIDE AND TROUBLESHOOTING GUIDE Implementation Report 5-4414-01-1 Project Number 5-4414-01 Subsurface Sensing Lab Electrical and Computer Engineering University of Houston 4800 Calhoun

More information

PHOTOSHOP1 15 / WORKSPACE

PHOTOSHOP1 15 / WORKSPACE MassArt Studio Foundation: Visual Language Digital Media Cookbook, Fall 2013 PHOTOSHOP1 15 / WORKSPACE Imaging software, just like our computers, relies on metaphors from the physical world for their design.

More information

UAT-600 Series. amprobe.com

UAT-600 Series. amprobe.com UAT-600 Series Underground Utilities Locator Accurately and safely pinpoint underground utilities before you dig Accidentally hitting a utility line during a project can lead to costly repairs and create

More information

R2009/R3016 Radar system Quick Reference Card

R2009/R3016 Radar system Quick Reference Card R2009/R3016 Radar system Quick Reference Card EN ¼¼ Note: This document covers the products: R2009 Radar system with 9 portrait display, paired with Halo, 3G, 4G or HD radar sensors. R3016 Radar system

More information

OPERATIONS MANUAL. narda MODEL 8513 INDUSTRIAL COMPLIANCE METER. for Electromagnetic Energy. Safety Test Solutions. P/N Rev B

OPERATIONS MANUAL. narda MODEL 8513 INDUSTRIAL COMPLIANCE METER. for Electromagnetic Energy. Safety Test Solutions. P/N Rev B MODEL 8513 INDUSTRIAL COMPLIANCE METER for Electromagnetic Energy OPERATIONS MANUAL narda Safety Test Solutions an communications company P/N 42985300 Rev B Table of Contents CHAPTER 1 INTRODUCTION...3

More information

Agilent 8920A RF Communications Test Set Product Overview

Agilent 8920A RF Communications Test Set Product Overview Agilent 8920A RF Communications Test Set Product Overview Cut through problems faster! The Agilent Technologies 8920A RF communications test set was designed to solve your radio testing and troubleshooting

More information

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write 3 Dynatel 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write Designed to be more accurate, faster and more integrated than any other locator on the market,

More information

EzOSD Manual. Overview & Operating Instructions Preliminary. April ImmersionRC EzOSD Manual 1

EzOSD Manual. Overview & Operating Instructions Preliminary. April ImmersionRC EzOSD Manual 1 EzOSD Manual Overview & Operating Instructions Preliminary. April 2009 ImmersionRC EzOSD Manual 1 Contents Overview... 3 Features... 3 Installation... 3 1. Installation using an ImmersionRC camera and

More information

Wixey TM INSTRUCTIONS

Wixey TM INSTRUCTIONS INSTRUCTIONS Wixey TM MODEL CJ410 Crown Molding and Trim Protractor Used to cut trim lying flat Calculates the compound miter and bevel angles for cutting crown molding and accurately sets your saw Features:

More information

Spectrum Analyzer TEN MINUTE TUTORIAL

Spectrum Analyzer TEN MINUTE TUTORIAL Spectrum Analyzer TEN MINUTE TUTORIAL November 4, 2011 Summary The Spectrum Analyzer option allows users who are familiar with RF spectrum analyzers to start using the FFT with little or no concern about

More information

2-Axis Force Platform PS-2142

2-Axis Force Platform PS-2142 Instruction Manual 012-09113B 2-Axis Force Platform PS-2142 Included Equipment 2-Axis Force Platform Part Number PS-2142 Required Equipment PASPORT Interface 1 See PASCO catalog or www.pasco.com Optional

More information

TECHNICAL INFORMATION GoldPanther Forensic Light Source Kit (Patent Pending) Cat. Nos. FAL2000, FAL

TECHNICAL INFORMATION GoldPanther Forensic Light Source Kit (Patent Pending) Cat. Nos. FAL2000, FAL SIRCHIE FINGER PRINT LABORATORIES, INC. Website: www.sirchie.com E-mail: sirchie@mindspring.com 100 HUNTER PLACE YOUNGSVILLE, NC 27596 USA Phone: (919) 554-2244, (800) 356-7311 Fax: (919) 554-2266, (800)

More information

PAMS. User s Manual. Portable Attenuation Measurement System. The solution for making easy shielding effectiveness measurements.

PAMS. User s Manual. Portable Attenuation Measurement System. The solution for making easy shielding effectiveness measurements. PAMS Portable Attenuation Measurement System User s Manual The solution for making easy shielding effectiveness measurements. 310-010042-001 TABLE OF CONTENTS Warranty Statement 1 Chapter 1 General Information

More information

EENG-201 Experiment # 4: Function Generator, Oscilloscope

EENG-201 Experiment # 4: Function Generator, Oscilloscope EENG-201 Experiment # 4: Function Generator, Oscilloscope I. Objectives Upon completion of this experiment, the student should be able to 1. To become familiar with the use of a function generator. 2.

More information

Moving Test - MT3000

Moving Test - MT3000 Moving Test - MT3000 Three-Phase Portable Test System Keep ahead with Modular Design The Modular Concept The MT3000 is based on a real modular design concept to provide the greatest possible flexibility

More information

QAM Snare Isolator User Manual

QAM Snare Isolator User Manual QAM Snare Isolator User Manual QS-ISO-1.6 9/1/15 This document details the functions and operation of the QAM Snare Isolator leakage detector Table of Contents Overview... 3 Screen Navigation... 4 Settings...

More information