1 Available on CMS information server CMS NOTE 1998/16 The Compact Muon Solenoid Experiment CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland January 1998 Performance test of the first prototype of 2 ways video camera for the Muon Barrel Position Monitor Laurent Brunel Kossuth University, Debrecen, Hungary and CERN, Geneva, Switzerland László Baksay, Tamás Bondár, Péter Raics, József Szabó, Kossuth University, Debrecen, Hungary Gy.L. Bencze KFKI Institute for Particle and Nuclear Physics, Budapest, Hungary and CERN,Geneva,Switzerland Abstract The CMS Barrel Position Monitor is based on 36 video cameras mounted on 36 very stable mechanical structures. One type of camera is used to observe optical sources mounted on the muon chambers. A first prototype was produced to test the main performances. This report gives the experimental results about stability, linearity and temperature effects. The work was supported by the Hungarian National Research Fund OTKA T 1794 and the Hungarian Higher Education Research Fund FKFP 31/1997.

2 Table of contents : 1. INTRODUCTION CAMERA BOX DESIGN OPTICAL DESIGN MECHANICAL DESIGN ELECTRONICS PERFORMANCE TESTS SET UP WHAT IS TESTED EXPECTED PERFORMANCE STABILITY SUB PIXEL LINEARITY LINEARITY ON A MOVEMENT OF FEW PIXELS FULL FIELD LINEARITY EFFECT OF THE TEMPERATURE CONCLUSION REFERENCES ANNEX

3 1. Introduction The positions of the muon chambers of the CMS experiment are precisely monitored with respect to each other and also with respect to the central detector. This is the role of the so called Muon Barrel Position Monitor. It is based on video cameras fixed on very stable mechanical structures called MABs ([1] [2] [3]). See Figure 18 for the Muon Barrel Monitor principle (see also the Muon Technical Design Report [1]). See Figure 19 for the design of the MAB. The video cameras are used for 3 purposes : 1- Look at optical sources mounted on the muon chambers. 2- Look at other MABs in order to provide an optical connection between the MABs. 3- Look at a Z bar mounted along the coil. The Z bars support optical sources at the level of each concerned MAB. This gives the z co-ordinate of the MABs. Hence one has 3 types of video cameras. The first type must look at sources in the distance range of [5mm, 75mm]. The second at 2 distances : 32mm and 47mm. The third one distance : about 5mm. The optical design of each type is different in order to get the best compromise between the field and the precision. The test of a prototype of the first type is presented in this report. This prototype contains the final optical elements and the final video sensor. The mechanical design (best stability, cost,...) will be optimised with the next prototype. 2. Camera box design 1. Optical design The same sensor is shared for two lenses thanks to 2 mirrors (see Figure 1). The angular incidence of the light on the sensor is 17 degrees. The standard lens used for the first prototype is a Melles Griot 1LPX15 (plan convex 15mm diameter, thickness 3.1 mm, focal length 5mm). The aperture of the lens is limited to a diameter of 1mm by a circular diaphragm. The lens is just a singlet to minimise the cost. It is plan-convex to get a minimum aberration for far objects. The mirror is a Microcontrole 72BD.1 (diameter 19.5mm, thickness 4.57mm) with imaging quality. The sensor is a Peach matrix sensor (VVL). It is a low cost integrated image sensor. The number of pixels is 312x287, the size of one pixel 19,6 x 16 microns 2 and the size of the sensitive part is 6.12x4.59 mm 2. Figure 1: Optical design of the 2 ways camera prototype. 2. Mechanical design This first prototype was design in a way that it can be easily machined in a very small workshop. Six plates are screwed together by 2 mm screws. The thickness of the plates is 3mm. The material is aluminium for easy machining. Each optical element is mounted on a holder fixed to these plates. The outer size of the box is designed to fit in the first MAB prototype. The Figure 2 shows the technical drawing of the prototype which was machined in Debrecen group for machining. The photographs of the camera box are shown in figure 3. 3

4 Figure 2: Technical design of the 2 ways camera prototype. Figure 3: Photographs of the prototype. The mirrors are at the bottom. The sensor is at the top. 3. Electronics The output of the video sensor is the standard CCIR video signal. This signal is sent to a frame grabber (Primo board from the Euresys company) which digitises it (ADC 8 bits), resamples the lines and stores the image in its memory. A C library permits to do some operations on this image : object detection and calculation of its centroid. The centroid is the calculated position of the object (horizontal and vertical co-ordinate in pixel unit) taking into account the intensity of light in each pixel. A particularity of this sensor is that, due to the small number of physical lines, the same line is repeated twice in the video signal in order to reach the standard CCIR number of lines. Then, just one line over two is acquired in order to get the same number of lines as the physical sensor. 4

5 3. Performance tests During one week, this camera box was tested on a small bench (see Figure 4). Only relative tests were performed like stability, linearity and temperature effect. Previous studies ([5] [6] [7]) using a standard camera box and a standard video lens where done, involving an absolute reference frame and studying the calibration of the camera box in this frame. 1. Set up The set-up is as follows. The camera box is rigidly fixed on a 1m long concrete table. The source is mounted on a precise translation stage. The stage is moved manually and the position is checked optically : a microscope permits to observe a precise ruler. The light source is a diffused LED mounted behind a diaphragm of 2 mm diameter (see Figure 5). The spot obtained on the video sensor has a size of about 2 pixels diameter. 8 mm Light source Camera prototype Optical table Translation Stage Figure 4: Set-up used for the test of performance : a precise translation stage (Karl Zeiss) displaces the source along an horizontal line. Figure 5 : Drawing of the source used : a diffused LED is placed behind a diaphragm of 2 mm diameter. 2. What is tested Here are the performance results that will be presented in this report : Stability : The difference between different measurements of an optical source which stays at the same place. Linearity : The optical source is displaced very precisely along a line. The camera set-up gives different centroid coordinates of the spot on the sensor. If the camera and the electronics are perfect, the curve showing the co- 5

6 ordinate measured by the camera with respect to the real displacement of the source is a perfect line. Three different tests will estimate the difference between the real measurements and the perfect line. Temperature effect : For a stable optical source the measurement consists in looking at the variation of the calculated co-ordinate when the temperature of the box changes. 3. Expected performance Simulation studies of the full barrel position monitor were made [4]. This simulation assumes that the chain : source, lens, sensor, electronics and processing brings in the sensor space an error of 1 micron sigma or 5% of a pixel. In a first approximation, this means that the error must stay in a range of +/- 2 microns or +/- 1% of a pixel. 4. Stability This test evaluates the short term (few minutes) stability. It focuses on the pure electronic noise. The Figure 6 shows the variation of centroid measurement for an untouched mechanical set-up. The calculated centroid varies randomly around an average value with a standard deviation of 2% of a pixel. By averaging a sequence of measurements done in a short time (few seconds), one can efficiently reduce this noise..1.8 Co-ordinate variation in pixels CentroidX CentroidY Image number (time scale) Figure 6: Stability. Vertical unit: pixel. Horizontal unit : number of the centroid calculation. During a short period of time (few minutes) the same spot is acquired and its centroid is evaluated. The diameter of the spot is around 2 pixels. The sigma is around 2% of a pixel. This noise is random and can be reduced by averaging. 5. Sub-pixel linearity In this test, the optical source is moved transversally so that the spot moves on the sensor by less than one pixel. It is not obvious that the centroid calculation reflects accurately a motion smaller than one pixel. The Figure 7 shows the result of this test. A displacement of.2mm at 8mm distance was with steps of 5 microns. An experimental curve is plotted expressing the calculated centroid with respect to the displacement read with the translation stage. The vertical unit is the pixel. The best line is fitted to this experimental curve. The Figure 8 shows the difference between the calculated co-ordinates and this best line or residuals. The result of this test is that the very small range linearity is correct, with a maximum error of 1.5% of a pixel. Remark : The centroid co-ordinate given here is averaged over 5 images acquired sequentially. This reduces the random noise. The error bars give an estimation of the resulting random noise (+/-.2 pixel). 6

7 centroid displacement in pixel Displacement at 8mm in mm. Figure 7: Sub pixel linearity test. Analyse of the behaviour of the centroid for a very small displacement (<1pixel). Fifty centroids are averaged for each point. At the right, the sketch shows the initial and final positions of the spot residuals Pixel Phi displacement at 8mm distance in mm Figure 8: Difference with the best line fitting for a displacement of the source corresponding to a movement of the spot of less than one pixel (.2 mm at 8mm distance corresponding to.8 pixel). The error bars represent the estimated random error after averaging a sequence of 5 acquisitions Linearity on a movement of few pixels Here, the same exercise is made with a slightly bigger range : 4 pixels which corresponds to a movement of 1mm at 8 mm distance. On Figure 9, one can see the calculated co-ordinate with respect to the transverse displacement of the source. As for the last part, this curve is compared to a fitted line. The residuals are shown in Figure 1. A periodicity of one pixel period can be observed. The result of this test is that the few pixels range linearity is correct, with a maximum error of 2% of a pixel. 7

8 Y centroid in pixels "Phi" displacement at 8mm distance in mm Figure 9: Linearity test for a displacement of 4 pixels which corresponds to 1 mm at 8mm distance from the camera. At the right, the sketch shows the initial and final position of the spot pixel.2 Residual in pixel Displacement at 8mm in mm Figure 1: Residual from the best line fitting. The error bars represent the estimated random error after averaging a sequence of 5 acquisitions. A periodicity of 1 pixel can be observed. 7. Full field linearity Here, one checks the linearity over the whole field. The source is moved horizontally (which corresponds to the CMS ri co-ordinate). For the sensor, a vertical movement is observed. The source is displaced by 5mm which corresponds to 2 pixels on the sensor. The residuals (see Figure 11) from the fitted line have a maximum of 7% of a pixel (1.1 micron). This result must be taken with a lot of care since, for this large movement, the source imperfections, the optical aberrations of the lens and the sensor matrix imperfection might bring errors. In the future, specific tests will be done in order to produce a good design for the optical source. The source used here is a LED diffused and put behind a small diaphragm of 2mm diameter. The aberrations of the plano-convex lens can be precisely calculated providing a good knowledge of the source. The optical aberration might bring a very regular error for 8

9 is not the case with the curve presented here. Therefore, other effects than just the optical aberrations are present. 25 Y centroid in pixels Full Sensor Phi displacement at 8mm in mm Figure 11: Full field linearity test over 5mm at 8mm distance. 2 pixels are covered..1.8 Residual from the best line in pixel Phi displacement at 8mm in mm Figure 12: Residuals of a line fitting of a full field linearity test (over 2 pixels vertically for the sensor). The error bars represent the estimated random error after averaging a sequence of 5 acquisitions. 8. Effect of the temperature Since the typical size of the camera box is 5mm and the material is aluminium (thermal expansion coefficient: 24x1-6 degree -1 ), one can expect relative displacements of the optical elements in the box of the order of 1.2 microns per degree. This is more than half a pixel (12 microns) for a temperature change of 1 degrees. Fortunately, not all the deformations affect the precision of the camera box. For example, a displacement along the optical axis changes the magnification only but doesn t change the position of the spot a the centre of the field and provokes a very little displacement at the border of the field (since the numerical aperture is low). The test is done by sending a hot air flow on the box. Three temperature sensors are mounted on the box : 2 are connected to the metal and one measures the temperature of the air inside the box. See Figure 13. The duration of this experiment is about 1 hour. The warming up phase is faster than the cooling down phase. So one can estimate that the thermal state of the box is better represented by the numbers given by the sensors during the cooling down period. 9

10 Temperature face 2 Temperature face 1 Temperature inside the camera Temperature (C) Temperature air inside the camera Temperature face 1 Temperature face 2 Figure 13: The temperature is taken on 3 points of the camera: 2 connected to metallic faces and one in the air inside the box Number of the temperature measurement Figure 14: There is coincidence between these 3 temperatures particularly during the slow cooling down phase (end part) Result: The change of the position of the light spot with respect to the temperature is shown in the Figure 16. No thermal effect is detected for the vertical co-ordinate of the sensor which corresponds to the CMS I coordinate(see Figure 15). The main effect is observed for the CMS r co-ordinate which corresponds to the horizontal co-ordinate of the sensor. There is a displacement of the spot on the sensor of about 5% of a pixel (1 microns) per degree. Video line Y (vertical) X (horizontal) r ri Sensor frame CMS frame Lens Mirror + mirror holder Figure 15: Scheme in 3D of the optical arrangement of one side of the camera box. The sensor is mounted such that the video lines correspond to the CMS r axis. 1

11 .5 Centroid coordinate variation in pixel X centroid (R) -1.5 Y centroid (Phi) -2 Temperature inside the box Warming up phase Cooling down phase Figure 16: Effect of the temperature on the centroid stability. Only the air temperature inside the box is plotted in this graph. There are two parts : warming up and cooling down part. The warming up part is the less sampled part. This effect can be explained by 2 main displacements : 1- The mirror is fixed on a prismatic holder. The dilatation of this holder make the mirror turning (about 15 microradian per degree which brings a displacement of the spot on the sensor of 1.62 microns per degree). 2- The full box dilates. Then the sensor moves up (by.86 micron per degree). Due to the incidence angle of 17 degrees, it implies a displacement of.26 microns per degree of the spot along the horizontal axis of the sensor (X axis). These 2 effects are compensating each other but the mirror rotation brings much bigger displacement of the light spot on the sensor (6 times more) than the box dilatation. If one chooses another material for the mirror holder such that the thermal expansion coefficient is 6 times lower than that of the aluminium (for example : glass), one can have 2 exactly compensating effects at the centre of the field. Nevertheless, the change of magnification would stay the same : a displacement of the spot of.7 micron per degree at the border of the field. warm position cold position Video sensor Mirror Mirror holder Figure 17: Schematic view of the 2 main effects of dilation. The mirror turns slightly and the sensor moves up. These 2 effects are compensating each other but the dilation of this holder brings bigger light spot displacement (6 times more) than the sensor translation. 11

12 4. Conclusion As explained in part 3.3, the error is considered to be satisfactory if it stays within the range +/-1% pixel or +/- 2 microns. This video camera is very satisfactory for these aspects : short term stability, sub-pixel linearity and small range linearity. The full field linearity is quite satisfactory. Nevertheless, more tests are needed particularly to understand the role of the source and the optical aberrations. The thermal stability is satisfactory in the CMS ri direction. For the CMS r direction, a non stability of 1 micron per degree has been detected. If the material of the mirror holder is adapted this non stability might go down to at the centre of the field and.7 micron per degree at the border of the field. The next table summarises these results : Source of error Maximum error measured Remark pixel micron Electronic noise 6% 1.2 Random (can be reduced efficiently) Sub pixel linearity 1.5%.3 Few pixels linearity 2.5%.5 Large field linearity 8% 1.4 Further studies needed (source) Temperature CMSIdirection Too small to be measured Too small to be measured In principle:.7 micron/degree at the border of the field. CMS r direction 5%/degree 1 micron/degree Can be in principle reduced to.7 micron/degree at the border of the field. 5. References [1.] Muon project Technical Design Report. [2.] L. Brunel CMS TN/ Muon Barrel Alignment. [3.] L. Brunel CMS TN/ Muon barrel alignment. Basic ideas. Third report. [4.] L. Brunel CMS-NOTE-96/18. Simulation of the muon barrel position monitor. [5.] L. Brunel CMS-TN-96/124. First manipulation for a video Camera Calibration [6.] L. Brunel CMS-TN-96/125. Second experiment for a video Camera Calibration [7.] L. Brunel CMS-NOTE-96/19. Video Camera Calibration. 12

13 6. Annex Figure 18: General view and principle of the Muon barrel position monitor. 13

14 Figure 19: an example of MAB (the position 3/-/1). There are 8 cameras of type 1 ( muon chamber cameras ) and 4 cameras of type 2 ( diagonal cameras ). 14

Chapter 18 Optical Elements

Chapter 18 Optical Elements Chapter 18 Optical Elements GOALS When you have mastered the content of this chapter, you will be able to achieve the following goals: Definitions Define each of the following terms and use it in an operational

More information

Name:.. KSU ID:. Date:././201..

Name:.. KSU ID:. Date:././201.. Name:.. KSU ID:. Date:././201.. Objective (1): Verification of law of reflection and determination of refractive index of Acrylic glass Required Equipment: (i) Optical bench, (ii) Glass lens, mounted,

More information

A novel solution for various monitoring applications at CERN

A novel solution for various monitoring applications at CERN A novel solution for various monitoring applications at CERN F. Lackner, P. H. Osanna 1, W. Riegler, H. Kopetz CERN, European Organisation for Nuclear Research, CH-1211 Geneva-23, Switzerland 1 Department

More information

2. Refraction and Reflection

2. Refraction and Reflection 2. Refraction and Reflection In this lab we will observe the displacement of a light beam by a parallel plate due to refraction. We will determine the refractive index of some liquids from the incident

More information

RESULTS OF 3D PHOTOGRAMMETRY ON THE CMS BARREL YOKE

RESULTS OF 3D PHOTOGRAMMETRY ON THE CMS BARREL YOKE RESULTS OF 3D PHOTOGRAMMETRY ON THE CMS BARREL YOKE R. GOUDARD, C. HUMBERTCLAUDE *1, K. NUMMIARO CERN, European Laboratory for Particle Physics, Geneva, Switzerland 1. INTRODUCTION Compact Muon Solenoid

More information

TWO TRANSPARENT OPTICAL SENSORS FOR THE POSITIONING OF DETECTORS USING A REFERENCE LASER BEAM

TWO TRANSPARENT OPTICAL SENSORS FOR THE POSITIONING OF DETECTORS USING A REFERENCE LASER BEAM TWO TRANSPARENT OPTICAL SENSORS FOR THE POSITIONING OF DETECTORS USING A REFERENCE LASER BEAM J.-Ch. Barrière, H. Blumenfeld, M. Bourdinaud, O. Cloué, C. Guyot, F. Molinié, P. Ponsot, J.-C. Saudemont,

More information

Week IV: FIRST EXPERIMENTS WITH THE ADVANCED OPTICS SET

Week IV: FIRST EXPERIMENTS WITH THE ADVANCED OPTICS SET Week IV: FIRST EXPERIMENTS WITH THE ADVANCED OPTICS SET The Advanced Optics set consists of (A) Incandescent Lamp (B) Laser (C) Optical Bench (with magnetic surface and metric scale) (D) Component Carriers

More information

ECEN 4606, UNDERGRADUATE OPTICS LAB

ECEN 4606, UNDERGRADUATE OPTICS LAB ECEN 4606, UNDERGRADUATE OPTICS LAB Lab 2: Imaging 1 the Telescope Original Version: Prof. McLeod SUMMARY: In this lab you will become familiar with the use of one or more lenses to create images of distant

More information

LENSES. a. To study the nature of image formed by spherical lenses. b. To study the defects of spherical lenses.

LENSES. a. To study the nature of image formed by spherical lenses. b. To study the defects of spherical lenses. Purpose Theory LENSES a. To study the nature of image formed by spherical lenses. b. To study the defects of spherical lenses. formation by thin spherical lenses s are formed by lenses because of the refraction

More information

Laboratory experiment aberrations

Laboratory experiment aberrations Laboratory experiment aberrations Obligatory laboratory experiment on course in Optical design, SK2330/SK3330, KTH. Date Name Pass Objective This laboratory experiment is intended to demonstrate the most

More information

P202/219 Laboratory IUPUI Physics Department THIN LENSES

P202/219 Laboratory IUPUI Physics Department THIN LENSES THIN LENSES OBJECTIVE To verify the thin lens equation, m = h i /h o = d i /d o. d o d i f, and the magnification equations THEORY In the above equations, d o is the distance between the object and the

More information

GEOMETRICAL OPTICS Practical 1. Part I. BASIC ELEMENTS AND METHODS FOR CHARACTERIZATION OF OPTICAL SYSTEMS

GEOMETRICAL OPTICS Practical 1. Part I. BASIC ELEMENTS AND METHODS FOR CHARACTERIZATION OF OPTICAL SYSTEMS GEOMETRICAL OPTICS Practical 1. Part I. BASIC ELEMENTS AND METHODS FOR CHARACTERIZATION OF OPTICAL SYSTEMS Equipment and accessories: an optical bench with a scale, an incandescent lamp, matte, a set of

More information

ADVANCED OPTICS LAB -ECEN Basic Skills Lab

ADVANCED OPTICS LAB -ECEN Basic Skills Lab ADVANCED OPTICS LAB -ECEN 5606 Basic Skills Lab Dr. Steve Cundiff and Edward McKenna, 1/15/04 Revised KW 1/15/06, 1/8/10 Revised CC and RZ 01/17/14 The goal of this lab is to provide you with practice

More information

TEST AND CALIBRATION FACILITY FOR HLS AND WPS SENSORS

TEST AND CALIBRATION FACILITY FOR HLS AND WPS SENSORS IWAA2004, CERN, Geneva, 4-7 October 2004 TEST AND CALIBRATION FACILITY FOR HLS AND WPS SENSORS Andreas Herty, Hélène Mainaud-Durand, Antonio Marin CERN, TS/SU/MTI, 1211 Geneva 23, Switzerland 1. ABSTRACT

More information

Radial Polarization Converter With LC Driver USER MANUAL

Radial Polarization Converter With LC Driver USER MANUAL ARCoptix Radial Polarization Converter With LC Driver USER MANUAL Arcoptix S.A Ch. Trois-portes 18 2000 Neuchâtel Switzerland Mail: info@arcoptix.com Tel: ++41 32 731 04 66 Principle of the radial polarization

More information

Chapter Ray and Wave Optics

Chapter Ray and Wave Optics 109 Chapter Ray and Wave Optics 1. An astronomical telescope has a large aperture to [2002] reduce spherical aberration have high resolution increase span of observation have low dispersion. 2. If two

More information

Very short introduction to light microscopy and digital imaging

Very short introduction to light microscopy and digital imaging Very short introduction to light microscopy and digital imaging Hernan G. Garcia August 1, 2005 1 Light Microscopy Basics In this section we will briefly describe the basic principles of operation and

More information

REFLECTION THROUGH LENS

REFLECTION THROUGH LENS REFLECTION THROUGH LENS A lens is a piece of transparent optical material with one or two curved surfaces to refract light rays. It may converge or diverge light rays to form an image. Lenses are mostly

More information

The BCAM Camera. ATLAS Internal Note. Kevan S Hashemi 1, James R Bensinger. Brandeis University. 15 September Introduction

The BCAM Camera. ATLAS Internal Note. Kevan S Hashemi 1, James R Bensinger. Brandeis University. 15 September Introduction ATLAS Internal Note The BCAM Camera Kevan S Hashemi 1, James R Bensinger Brandeis University 15 September 2000 Abstract: The BCAM, or Boston CCD Angle Monitor, is a camera looking at one or more light

More information

Opto Engineering S.r.l.

Opto Engineering S.r.l. TUTORIAL #1 Telecentric Lenses: basic information and working principles On line dimensional control is one of the most challenging and difficult applications of vision systems. On the other hand, besides

More information

This experiment is under development and thus we appreciate any and all comments as we design an interesting and achievable set of goals.

This experiment is under development and thus we appreciate any and all comments as we design an interesting and achievable set of goals. Experiment 7 Geometrical Optics You will be introduced to ray optics and image formation in this experiment. We will use the optical rail, lenses, and the camera body to quantify image formation and magnification;

More information

1 st IFAC Conference on Mechatronic Systems - Mechatronics 2000, September 18-20, 2000, Darmstadt, Germany

1 st IFAC Conference on Mechatronic Systems - Mechatronics 2000, September 18-20, 2000, Darmstadt, Germany 1 st IFAC Conference on Mechatronic Systems - Mechatronics 2000, September 18-20, 2000, Darmstadt, Germany SPACE APPLICATION OF A SELF-CALIBRATING OPTICAL PROCESSOR FOR HARSH MECHANICAL ENVIRONMENT V.

More information

Optical System Design

Optical System Design Phys 531 Lecture 12 14 October 2004 Optical System Design Last time: Surveyed examples of optical systems Today, discuss system design Lens design = course of its own (not taught by me!) Try to give some

More information

PROCEEDINGS OF SPIE. Measurement of low-order aberrations with an autostigmatic microscope

PROCEEDINGS OF SPIE. Measurement of low-order aberrations with an autostigmatic microscope PROCEEDINGS OF SPIE SPIEDigitalLibrary.org/conference-proceedings-of-spie Measurement of low-order aberrations with an autostigmatic microscope William P. Kuhn Measurement of low-order aberrations with

More information

Final Reg Optics Review SHORT ANSWER. Write the word or phrase that best completes each statement or answers the question.

Final Reg Optics Review SHORT ANSWER. Write the word or phrase that best completes each statement or answers the question. Final Reg Optics Review 1) How far are you from your image when you stand 0.75 m in front of a vertical plane mirror? 1) 2) A object is 12 cm in front of a concave mirror, and the image is 3.0 cm in front

More information

Supplementary Figure 1

Supplementary Figure 1 Supplementary Figure 1 Technical overview drawing of the Roadrunner goniometer. The goniometer consists of three main components: an inline sample-viewing microscope, a high-precision scanning unit for

More information

ALIGNMENT METHODS APPLIED TO THE LEP MAGNET MEASUREMENTS. J. Billan, G. Brun, K. N. Henrichsen, P. Legrand, 0. Pagano, P. Rohmig and L. Walckiers.

ALIGNMENT METHODS APPLIED TO THE LEP MAGNET MEASUREMENTS. J. Billan, G. Brun, K. N. Henrichsen, P. Legrand, 0. Pagano, P. Rohmig and L. Walckiers. 295 ALIGNMENT METHODS APPLIED TO THE LEP MAGNET MEASUREMENTS J. Billan, G. Brun, K. N. Henrichsen, P. Legrand, 0. Pagano, P. Rohmig and L. Walckiers. CERN, CH-1211 Geneva 23, Switzerland Introduction Electromagnets

More information

The optical analysis of the proposed Schmidt camera design.

The optical analysis of the proposed Schmidt camera design. The optical analysis of the proposed Schmidt camera design. M. Hrabovsky, M. Palatka, P. Schovanek Joint Laboratory of Optics of Palacky University and Institute of Physics of the Academy of Sciences of

More information

1.6 Beam Wander vs. Image Jitter

1.6 Beam Wander vs. Image Jitter 8 Chapter 1 1.6 Beam Wander vs. Image Jitter It is common at this point to look at beam wander and image jitter and ask what differentiates them. Consider a cooperative optical communication system that

More information

The Henryk Niewodniczański INSTITUTE OF NUCLEAR PHYSICS Polish Academy of Sciences ul. Radzikowskiego 152, Kraków, Poland.

The Henryk Niewodniczański INSTITUTE OF NUCLEAR PHYSICS Polish Academy of Sciences ul. Radzikowskiego 152, Kraków, Poland. The Henryk Niewodniczański INSTITUTE OF NUCLEAR PHYSICS Polish Academy of Sciences ul. Radzikowskiego 152, 31-342 Kraków, Poland. www.ifj.edu.pl/reports/2003.html Kraków, grudzień 2003 Report No 1931/PH

More information

OPTICAL SYSTEMS OBJECTIVES

OPTICAL SYSTEMS OBJECTIVES 101 L7 OPTICAL SYSTEMS OBJECTIVES Aims Your aim here should be to acquire a working knowledge of the basic components of optical systems and understand their purpose, function and limitations in terms

More information

Synopsis of paper. Optomechanical design of multiscale gigapixel digital camera. Hui S. Son, Adam Johnson, et val.

Synopsis of paper. Optomechanical design of multiscale gigapixel digital camera. Hui S. Son, Adam Johnson, et val. Synopsis of paper --Xuan Wang Paper title: Author: Optomechanical design of multiscale gigapixel digital camera Hui S. Son, Adam Johnson, et val. 1. Introduction In traditional single aperture imaging

More information

Optical design of a high resolution vision lens

Optical design of a high resolution vision lens Optical design of a high resolution vision lens Paul Claassen, optical designer, paul.claassen@sioux.eu Marnix Tas, optical specialist, marnix.tas@sioux.eu Prof L.Beckmann, l.beckmann@hccnet.nl Summary:

More information

OPTICAL BENCH - simple type

OPTICAL BENCH - simple type GENERAL DESCRIPTION: OPTICAL BENCH - simple type Cat: HL2240-001 Complete with Hodson Light Box. Cat: HL2241-001 Not including Hodson Light Box The IEC Optical Bench system is designed to be used with

More information

Performance Factors. Technical Assistance. Fundamental Optics

Performance Factors.   Technical Assistance. Fundamental Optics Performance Factors After paraxial formulas have been used to select values for component focal length(s) and diameter(s), the final step is to select actual lenses. As in any engineering problem, this

More information

Bias errors in PIV: the pixel locking effect revisited.

Bias errors in PIV: the pixel locking effect revisited. Bias errors in PIV: the pixel locking effect revisited. E.F.J. Overmars 1, N.G.W. Warncke, C. Poelma and J. Westerweel 1: Laboratory for Aero & Hydrodynamics, University of Technology, Delft, The Netherlands,

More information

Devices & Services Company

Devices & Services Company Devices & Services Company 10290 Monroe Drive, Suite 202 - Dallas, Texas 75229 USA - Tel. 214-902-8337 - Fax 214-902-8303 Web: www.devicesandservices.com Email: sales@devicesandservices.com D&S Technical

More information

Acceptance test for the linear motion actuator for the scanning slit of the HIE ISOLDE short diagnostic boxes

Acceptance test for the linear motion actuator for the scanning slit of the HIE ISOLDE short diagnostic boxes EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN ACC NOTE 2014 0099 HIE ISOLDE PROJECT Note 0036 Acceptance test for the linear motion actuator for the scanning slit of the HIE ISOLDE short diagnostic boxes

More information

ADVANCED OPTICS LAB -ECEN 5606

ADVANCED OPTICS LAB -ECEN 5606 ADVANCED OPTICS LAB -ECEN 5606 Basic Skills Lab Dr. Steve Cundiff and Edward McKenna, 1/15/04 rev KW 1/15/06, 1/8/10 The goal of this lab is to provide you with practice of some of the basic skills needed

More information

A tutorial for designing. fundamental imaging systems

A tutorial for designing. fundamental imaging systems A tutorial for designing fundamental imaging systems OPTI 521 College of Optical Science University of Arizona November 2009 Abstract This tutorial shows what to do when we design opto-mechanical system

More information

Telecentric lenses.

Telecentric lenses. Telecentric lenses 2014 Bi-Telecentric lenses Titolo Index Descrizione Telecentric lenses Opto Engineering Telecentric lenses represent our core business: these products benefit from a decade-long effort

More information

General Physics Experiment 5 Optical Instruments: Simple Magnifier, Microscope, and Newtonian Telescope

General Physics Experiment 5 Optical Instruments: Simple Magnifier, Microscope, and Newtonian Telescope General Physics Experiment 5 Optical Instruments: Simple Magnifier, Microscope, and Newtonian Telescope Objective: < To observe the magnifying properties of the simple magnifier, the microscope and the

More information

04. REFRACTION OF LIGHT AT CURVED SURFACES

04. REFRACTION OF LIGHT AT CURVED SURFACES CLASS-10 PHYSICAL SCIENCE 04. REFRACTION OF LIGHT AT CURVED SURFACES Questions and Answers *Reflections on Concepts* 1. Write the lens maker s formula and explain the terms in it. A. Lens maker s formula

More information

INSTRUCTION MANUAL FOR THE MODEL C OPTICAL TESTER

INSTRUCTION MANUAL FOR THE MODEL C OPTICAL TESTER INSTRUCTION MANUAL FOR THE MODEL C OPTICAL TESTER INSTRUCTION MANUAL FOR THE MODEL C OPTICAL TESTER Data Optics, Inc. (734) 483-8228 115 Holmes Road or (800) 321-9026 Ypsilanti, Michigan 48198-3020 Fax:

More information

EXPERIMENT 4 INVESTIGATIONS WITH MIRRORS AND LENSES 4.2 AIM 4.1 INTRODUCTION

EXPERIMENT 4 INVESTIGATIONS WITH MIRRORS AND LENSES 4.2 AIM 4.1 INTRODUCTION EXPERIMENT 4 INVESTIGATIONS WITH MIRRORS AND LENSES Structure 4.1 Introduction 4.2 Aim 4.3 What is Parallax? 4.4 Locating Images 4.5 Investigations with Real Images Focal Length of a Concave Mirror Focal

More information

Kit for building your own THz Time-Domain Spectrometer

Kit for building your own THz Time-Domain Spectrometer Kit for building your own THz Time-Domain Spectrometer 16/06/2016 1 Table of contents 0. Parts for the THz Kit... 3 1. Delay line... 4 2. Pulse generator and lock-in detector... 5 3. THz antennas... 6

More information

Practice Problems (Geometrical Optics)

Practice Problems (Geometrical Optics) 1 Practice Problems (Geometrical Optics) 1. A convex glass lens (refractive index = 3/2) has a focal length of 8 cm when placed in air. What is the focal length of the lens when it is immersed in water

More information

Aberrations of a lens

Aberrations of a lens Aberrations of a lens 1. What are aberrations? A lens made of a uniform glass with spherical surfaces cannot form perfect images. Spherical aberration is a prominent image defect for a point source on

More information

R.B.V.R.R. WOMEN S COLLEGE (AUTONOMOUS) Narayanaguda, Hyderabad.

R.B.V.R.R. WOMEN S COLLEGE (AUTONOMOUS) Narayanaguda, Hyderabad. R.B.V.R.R. WOMEN S COLLEGE (AUTONOMOUS) Narayanaguda, Hyderabad. DEPARTMENT OF PHYSICS QUESTION BANK FOR SEMESTER III PAPER III OPTICS UNIT I: 1. MATRIX METHODS IN PARAXIAL OPTICS 2. ABERATIONS UNIT II

More information

INTRODUCTION THIN LENSES. Introduction. given by the paraxial refraction equation derived last lecture: Thin lenses (19.1) = 1. Double-lens systems

INTRODUCTION THIN LENSES. Introduction. given by the paraxial refraction equation derived last lecture: Thin lenses (19.1) = 1. Double-lens systems Chapter 9 OPTICAL INSTRUMENTS Introduction Thin lenses Double-lens systems Aberrations Camera Human eye Compound microscope Summary INTRODUCTION Knowledge of geometrical optics, diffraction and interference,

More information

Laser Diode Mounting Kits

Laser Diode Mounting Kits Laser Diode Mounting Kits For Ø5.6mm and Ø9mm Laser Diodes Complete Mounting System with Collimating Lens If your work involves laser diodes, you ll appreciate the benefits of Optima s laser diode mounting

More information

Lenses. Optional Reading Stargazer: the life and times of the TELESCOPE, Fred Watson (Da Capo 2004).

Lenses. Optional Reading Stargazer: the life and times of the TELESCOPE, Fred Watson (Da Capo 2004). Lenses Equipment optical bench, incandescent light source, laser, No 13 Wratten filter, 3 lens holders, cross arrow, diffuser, white screen, case of lenses etc., vernier calipers, 30 cm ruler, meter stick

More information

Applying of refractive beam shapers of circular symmetry to generate non-circular shapes of homogenized laser beams

Applying of refractive beam shapers of circular symmetry to generate non-circular shapes of homogenized laser beams - 1 - Applying of refractive beam shapers of circular symmetry to generate non-circular shapes of homogenized laser beams Alexander Laskin a, Vadim Laskin b a MolTech GmbH, Rudower Chaussee 29-31, 12489

More information

ON THE REDUCTION OF SUB-PIXEL ERROR IN IMAGE BASED DISPLACEMENT MEASUREMENT

ON THE REDUCTION OF SUB-PIXEL ERROR IN IMAGE BASED DISPLACEMENT MEASUREMENT 5 XVII IMEKO World Congress Metrology in the 3 rd Millennium June 22 27, 2003, Dubrovnik, Croatia ON THE REDUCTION OF SUB-PIXEL ERROR IN IMAGE BASED DISPLACEMENT MEASUREMENT Alfredo Cigada, Remo Sala,

More information

Instructions. To run the slideshow:

Instructions. To run the slideshow: Instructions To run the slideshow: Click: view full screen mode, or press Ctrl +L. Left click advances one slide, right click returns to previous slide. To exit the slideshow press the Esc key. Optical

More information

Polarization Experiments Using Jones Calculus

Polarization Experiments Using Jones Calculus Polarization Experiments Using Jones Calculus Reference http://chaos.swarthmore.edu/courses/physics50_2008/p50_optics/04_polariz_matrices.pdf Theory In Jones calculus, the polarization state of light is

More information

ACEEE Int. J. on Electrical and Power Engineering, Vol. 03, No. 02, May 2012

ACEEE Int. J. on Electrical and Power Engineering, Vol. 03, No. 02, May 2012 Effect of Glittering and Reflective Objects of Different Colors to the Output Voltage-Distance Characteristics of Sharp GP2D120 IR M.R. Yaacob 1, N.S.N. Anwar 1 and A.M. Kassim 1 1 Faculty of Electrical

More information

Some Progress In The Development Of An Optical Readout System For The LISA Gravitational Reference Sensor

Some Progress In The Development Of An Optical Readout System For The LISA Gravitational Reference Sensor Some Progress In The Development Of An Optical Readout System For The LISA Gravitational Reference Sensor Fausto ~cernese*', Rosario De ~ osa*~, Luciano Di Fiore*, Fabio ~arufi*', Adele La ~ana*' and Leopoldo

More information

A LATERAL SENSOR FOR THE ALIGNMENT OF TWO FORMATION-FLYING SATELLITES

A LATERAL SENSOR FOR THE ALIGNMENT OF TWO FORMATION-FLYING SATELLITES A LATERAL SENSOR FOR THE ALIGNMENT OF TWO FORMATION-FLYING SATELLITES S. Roose (1), Y. Stockman (1), Z. Sodnik (2) (1) Centre Spatial de Liège, Belgium (2) European Space Agency - ESA/ESTEC slide 1 Outline

More information

PHYS 1112L - Introductory Physics Laboratory II

PHYS 1112L - Introductory Physics Laboratory II PHYS 1112L - Introductory Physics Laboratory II Laboratory Advanced Sheet Thin Lenses 1. Objectives. The objectives of this laboratory are a. to be able to measure the focal length of a converging lens.

More information

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope Kenichi Ikeda 1, Hideyuki Kotaki 1 ' 2 and Kazuhisa Nakajima 1 ' 2 ' 3 1 Graduate University for Advanced

More information

Technical Explanation for Displacement Sensors and Measurement Sensors

Technical Explanation for Displacement Sensors and Measurement Sensors Technical Explanation for Sensors and Measurement Sensors CSM_e_LineWidth_TG_E_2_1 Introduction What Is a Sensor? A Sensor is a device that measures the distance between the sensor and an object by detecting

More information

THE SEQUENTIAL TRACKING OF TARGETS IN A REMOTE EXPERIMENTAL ENVIRONMENT.

THE SEQUENTIAL TRACKING OF TARGETS IN A REMOTE EXPERIMENTAL ENVIRONMENT. THE SEQUENTIAL TRACKING OF TARGETS IN A REMOTE EXPERIMENTAL ENVIRONMENT. T.A. Clarke, S. Robson, D.N. Qu, X. Wang, M.A.R. Cooper, R.N. Taylor. Centre for Digital Image Measurement & Analysis, School of

More information

Reading: Lenses and Mirrors; Applications Key concepts: Focal points and lengths; real images; virtual images; magnification; angular magnification.

Reading: Lenses and Mirrors; Applications Key concepts: Focal points and lengths; real images; virtual images; magnification; angular magnification. Reading: Lenses and Mirrors; Applications Key concepts: Focal points and lengths; real images; virtual images; magnification; angular magnification. 1.! Questions about objects and images. Can a virtual

More information

ENSC 470/894 Lab 1 V2.0 (Sept )

ENSC 470/894 Lab 1 V2.0 (Sept ) ENSC 470/894 Lab 1 V2.0 (Sept. 22 2013) Introduction: Lab 1 is designed to give students basic experience in optics. In the lab you will set up lenses on an optical table, with a LCD screen pattern as

More information

Metrology Studies and Baseplate-Pixel Sensor Gluing of the Pixel Strip Modules for the CMS II Phase Upgrade

Metrology Studies and Baseplate-Pixel Sensor Gluing of the Pixel Strip Modules for the CMS II Phase Upgrade Metrology Studies and Baseplate-Pixel Sensor Gluing of the Pixel Strip Modules for the CMS II Phase Upgrade Author: Jem Aizen M. Guhit Supervisors: James Keaveney Marino Missiroli Abstract The upcoming

More information

Determination of Focal Length of A Converging Lens and Mirror

Determination of Focal Length of A Converging Lens and Mirror Physics 41 Determination of Focal Length of A Converging Lens and Mirror Objective: Apply the thin-lens equation and the mirror equation to determine the focal length of a converging (biconvex) lens and

More information

Exercise questions for Machine vision

Exercise questions for Machine vision Exercise questions for Machine vision This is a collection of exercise questions. These questions are all examination alike which means that similar questions may appear at the written exam. I ve divided

More information

PHYS 160 Astronomy. When analyzing light s behavior in a mirror or lens, it is helpful to use a technique called ray tracing.

PHYS 160 Astronomy. When analyzing light s behavior in a mirror or lens, it is helpful to use a technique called ray tracing. Optics Introduction In this lab, we will be exploring several properties of light including diffraction, reflection, geometric optics, and interference. There are two sections to this lab and they may

More information

Supplementary Notes to. IIT JEE Physics. Topic-wise Complete Solutions

Supplementary Notes to. IIT JEE Physics. Topic-wise Complete Solutions Supplementary Notes to IIT JEE Physics Topic-wise Complete Solutions Geometrical Optics: Focal Length of a Concave Mirror and a Convex Lens using U-V Method Jitender Singh Shraddhesh Chaturvedi PsiPhiETC

More information

LOS 1 LASER OPTICS SET

LOS 1 LASER OPTICS SET LOS 1 LASER OPTICS SET Contents 1 Introduction 3 2 Light interference 5 2.1 Light interference on a thin glass plate 6 2.2 Michelson s interferometer 7 3 Light diffraction 13 3.1 Light diffraction on a

More information

Lab 5: Brewster s Angle and Polarization. I. Brewster s angle

Lab 5: Brewster s Angle and Polarization. I. Brewster s angle Lab 5: Brewster s Angle and Polarization I. Brewster s angle CAUTION: The beam splitters are sensitive pieces of optical equipment; the oils on your fingertips if left there will degrade the coatings on

More information

Waves & Oscillations

Waves & Oscillations Physics 42200 Waves & Oscillations Lecture 33 Geometric Optics Spring 2013 Semester Matthew Jones Aberrations We have continued to make approximations: Paraxial rays Spherical lenses Index of refraction

More information

PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry

PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry Purpose PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry In this experiment, you will study the principles and applications of interferometry. Equipment and components PASCO

More information

1.3. Before loading the holder into the TEM, make sure the X tilt is set to zero and the goniometer locked in place (this will make loading easier).

1.3. Before loading the holder into the TEM, make sure the X tilt is set to zero and the goniometer locked in place (this will make loading easier). JEOL 200CX operating procedure Nicholas G. Rudawski ngr@ufl.edu (805) 252-4916 1. Specimen loading 1.1. Unlock the TUMI system. 1.2. Load specimen(s) into the holder. If using the double tilt holder, ensure

More information

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit Experiment 1: Fraunhofer Diffraction of Light by a Single Slit Purpose 1. To understand the theory of Fraunhofer diffraction of light at a single slit and at a circular aperture; 2. To learn how to measure

More information

The ATLAS Toroid Magnet

The ATLAS Toroid Magnet The ATLAS Toroid Magnet SUN Zhihong CEA Saclay DAPNIA/SIS 1 The ATLAS Magnet System The ATLAS Barrel Toroid Mechanical computations on the Barrel Toroid structure Manufacturing and assembly of the Barrel

More information

Instruction manual for T3DS software. Tool for THz Time-Domain Spectroscopy. Release 4.0

Instruction manual for T3DS software. Tool for THz Time-Domain Spectroscopy. Release 4.0 Instruction manual for T3DS software Release 4.0 Table of contents 0. Setup... 3 1. Start-up... 5 2. Input parameters and delay line control... 6 3. Slow scan measurement... 8 4. Fast scan measurement...

More information

Tutorial Zemax 9: Physical optical modelling I

Tutorial Zemax 9: Physical optical modelling I Tutorial Zemax 9: Physical optical modelling I 2012-11-04 9 Physical optical modelling I 1 9.1 Gaussian Beams... 1 9.2 Physical Beam Propagation... 3 9.3 Polarization... 7 9.4 Polarization II... 11 9 Physical

More information

Comparison of FRD (Focal Ratio Degradation) for Optical Fibres with Different Core Sizes By Neil Barrie

Comparison of FRD (Focal Ratio Degradation) for Optical Fibres with Different Core Sizes By Neil Barrie Comparison of FRD (Focal Ratio Degradation) for Optical Fibres with Different Core Sizes By Neil Barrie Introduction The purpose of this experimental investigation was to determine whether there is a dependence

More information

MUSKY: Multispectral UV Sky camera. Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM

MUSKY: Multispectral UV Sky camera. Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM MUSKY: Multispectral UV Sky camera Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM Outline Purpose of the instrument Required specs Hyperspectral or multispectral? Optical design

More information

1 Thin Lenses and Thin Lens Combinations

1 Thin Lenses and Thin Lens Combinations SIMG-232 LABORATORY #4 Thin Lenses and Thin Lens Combinations. Abstract: This laboratory considers several concepts in geometrical optics and thin lenses: the assumption of rectilinear propagation (light

More information

Supplementary Materials

Supplementary Materials Supplementary Materials In the supplementary materials of this paper we discuss some practical consideration for alignment of optical components to help unexperienced users to achieve a high performance

More information

PH 481/581 Physical Optics Winter 2014

PH 481/581 Physical Optics Winter 2014 PH 481/581 Physical Optics Winter 2014 Laboratory #1 Week of January 13 Read: Handout (Introduction & Projects #2 & 3 from Newport Project in Optics Workbook), pp.150-170 of Optics by Hecht Do: 1. Experiment

More information

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions Difrotec Product & Services Ultra high accuracy interferometry & custom optical solutions Content 1. Overview 2. Interferometer D7 3. Benefits 4. Measurements 5. Specifications 6. Applications 7. Cases

More information

Using molded chalcogenide glass technology to reduce cost in a compact wide-angle thermal imaging lens

Using molded chalcogenide glass technology to reduce cost in a compact wide-angle thermal imaging lens Using molded chalcogenide glass technology to reduce cost in a compact wide-angle thermal imaging lens George Curatu a, Brent Binkley a, David Tinch a, and Costin Curatu b a LightPath Technologies, 2603

More information

Part 1 Investigating Snell s Law

Part 1 Investigating Snell s Law Geometric Optics with Lenses PURPOSE: To observe the refraction of light off through lenses; to investigate the relationship between objects and images; to study the relationship between object distance,

More information

Section 3. Imaging With A Thin Lens

Section 3. Imaging With A Thin Lens 3-1 Section 3 Imaging With A Thin Lens Object at Infinity An object at infinity produces a set of collimated set of rays entering the optical system. Consider the rays from a finite object located on the

More information

Astigmatism Particle Tracking Velocimetry for Macroscopic Flows

Astigmatism Particle Tracking Velocimetry for Macroscopic Flows 1TH INTERNATIONAL SMPOSIUM ON PARTICLE IMAGE VELOCIMETR - PIV13 Delft, The Netherlands, July 1-3, 213 Astigmatism Particle Tracking Velocimetry for Macroscopic Flows Thomas Fuchs, Rainer Hain and Christian

More information

MULTI-POINT WIDE-RANGE PRECISION ALIGNMENT BASED ON A STRETCHED WIRE TECHNIQUE

MULTI-POINT WIDE-RANGE PRECISION ALIGNMENT BASED ON A STRETCHED WIRE TECHNIQUE II/119 MULTI-POINT WIDE-RANGE PRECISION ALIGNMENT BASED ON A STRETCHED WIRE TECHNIQUE Andrey Korytov Massachusetts Institute of Technology, Cambridge, Massachusetts, USA SUMMARY A novel, simple and inexpensive

More information

Lab 2 Geometrical Optics

Lab 2 Geometrical Optics Lab 2 Geometrical Optics March 22, 202 This material will span much of 2 lab periods. Get through section 5.4 and time permitting, 5.5 in the first lab. Basic Equations Lensmaker s Equation for a thin

More information

Opti 415/515. Introduction to Optical Systems. Copyright 2009, William P. Kuhn

Opti 415/515. Introduction to Optical Systems. Copyright 2009, William P. Kuhn Opti 415/515 Introduction to Optical Systems 1 Optical Systems Manipulate light to form an image on a detector. Point source microscope Hubble telescope (NASA) 2 Fundamental System Requirements Application

More information

always positive for virtual image

always positive for virtual image Point to be remembered: sign convention for Spherical mirror Object height, h = always positive Always +ve for virtual image Image height h = Always ve for real image. Object distance from pole (u) = always

More information

Laser Telemetric System (Metrology)

Laser Telemetric System (Metrology) Laser Telemetric System (Metrology) Laser telemetric system is a non-contact gauge that measures with a collimated laser beam (Refer Fig. 10.26). It measure at the rate of 150 scans per second. It basically

More information

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

Optical Coherence: Recreation of the Experiment of Thompson and Wolf Optical Coherence: Recreation of the Experiment of Thompson and Wolf David Collins Senior project Department of Physics, California Polytechnic State University San Luis Obispo June 2010 Abstract The purpose

More information

A Study of undulator magnets characterization using the Vibrating Wire technique

A Study of undulator magnets characterization using the Vibrating Wire technique A Study of undulator magnets characterization using the Vibrating Wire technique Alexander. Temnykh a, Yurii Levashov b and Zachary Wolf b a Cornell University, Laboratory for Elem-Particle Physics, Ithaca,

More information

Feasibility and Design for the Simplex Electronic Telescope. Brian Dodson

Feasibility and Design for the Simplex Electronic Telescope. Brian Dodson Feasibility and Design for the Simplex Electronic Telescope Brian Dodson Charge: A feasibility check and design hints are wanted for the proposed Simplex Electronic Telescope (SET). The telescope is based

More information

Technical Note How to Compensate Lateral Chromatic Aberration

Technical Note How to Compensate Lateral Chromatic Aberration Lateral Chromatic Aberration Compensation Function: In JAI color line scan cameras (3CCD/4CCD/3CMOS/4CMOS), sensors and prisms are precisely fabricated. On the other hand, the lens mounts of the cameras

More information

Week IX: INTERFEROMETER EXPERIMENTS

Week IX: INTERFEROMETER EXPERIMENTS Week IX: INTERFEROMETER EXPERIMENTS Notes on Adjusting the Michelson Interference Caution: Do not touch the mirrors or beam splitters they are front surface and difficult to clean without damaging them.

More information

Parity and Plane Mirrors. Invert Image flip about a horizontal line. Revert Image flip about a vertical line.

Parity and Plane Mirrors. Invert Image flip about a horizontal line. Revert Image flip about a vertical line. Optical Systems 37 Parity and Plane Mirrors In addition to bending or folding the light path, reflection from a plane mirror introduces a parity change in the image. Invert Image flip about a horizontal

More information