LaserBeam ProfilingSolutions. IRLaserBeam Profiler

Size: px
Start display at page:

Download "LaserBeam ProfilingSolutions. IRLaserBeam Profiler"

Transcription

1 LaserBeam ProfilingSolutions IRLaserBeam Profiler

2 TABLE OF CONTENTS PRODUCT DESCRIPTION LASERDEC CL200 TECHNICAL DATA DIMENSIONS LASERDEC CL500 TECHNICAL DATA DIMENSIONS LASERDEC CR200 TECHNICAL DATA DIMENSIONS ACCESSORIES ATTENUATION UNIT 0 ATTENUATION UNIT 90 BEAM REDUCER IR MICROSCOPE OBJECTIVE BEAM PROFILING SOFTWARE RAYCI

3 LaserDec CL/CR - Product Description - The high performance LaserDec system is based on industry s unique imaging technique. It is designed for monitoring high-power IR-lasers in best performance. Thanks to its high resolution and its incomparable real-time capabilities, this highly efficient beam profiler is optimized for laser beam analysis of continuous wave (cw) and pulsed laser systems. The LaserDec system ensures beam profiling: By high frame rates and high resolution Without optical components in the beam path Without scanning techniques, fluorescent materials or toxic fumes through acrylic mode burns. Spectral response: µm Effective pixel size: ~45µm - ~124µm Resolution: 320 x 240pixel / 640 x 480pixel Technologie: Image Converter Data output: 14Bit Interface: FireWire 1394b / GigE LaserDec CL The LaserDec CL is optimized to provide excellent sensitivity from 8µm-12µm spectral range. This model provides unique beam analysis capabilities for CO 2-Laser wavelengths. LaserDec CR The LaserDec CR is optimized to provide excellent sensitivity from 1.5µm-8µm spectral range. The wide application spectrum ranges from high-power telecom lasers to medical lasers. The plug & play design and the ultra-fast FireWire 1394b / GigE interface facilitate easy and flexible integration and operation. The portable LaserDec is designed to be used in a variety of applications in industry, science, R&D, including: Laser beam analysis of high-power IR lasers Quick control of laser modes and adjustment errors Test equipment for scientific research Near-Field and Far-Field analyses of lasers.

4 LaserDec CL200 - Technical Data - CL200 CL200 HP CL200 HP - HS Standard High Performance High Sensitivity IMAGE CONVERTER Spectral sensitivity: 8µm - 12µm 8µm - 12µm 8µm - 12µm Clear aperture: =20mm =20mm =20mm Beam diameter (1/e 2 ): 1mm - 10mm 1mm - 10mm 1mm - 10mm Intensity range: 10W/cm W/cm 2 20W/cm W/cm 2 1W/cm 2-100W/cm 2 Input power (max): 200W 200W 50W With attenuation unit 0 : up to 2kW up to 2kW up to 1kW With attenuation unit 90 : up to 2.5kW up to 2.5kW up to 1.5kW Effective pixel size*: ~90µm ~45µm ~ 45µm CAMERA FEATURES Sensor: CCD CCD CCD Resolution*: 320 x 240pixel 640 x 480pixel 640 x 480pixel Bit depth (output): 14 Bit 14 Bit 14 Bit Frame rate: up to 20Hz up to 20Hz up to 20Hz Interface: FireWire 1394b / GigE FireWire 1394b / GigE FireWire 1394b / GigE Mode: cw or pulsed cw or pulsed cw or pulsed SPECIFICATIONS Mechanical dimensions (W x H x L): 298mm x 141mm x 76mm 298mm x 141mm x 76mm 298mm x 141mm x 76mm Weight: 2.6kg 2.6kg 2.7kg Electrical requirements: AC120V/240V; 48-63Hz; 285W AC120V/240V; 48-63Hz; 285W AC120V/240V; 48-63Hz; 285W Storage temperature**: 0 C +60 C 0 C +60 C 0 C +60 C Operating temperature**: +5 C +35 C +5 C +35 C +5 C +35 C Humidity: 20%...80% 20%...80% 20%...80% Regulations: CE, RoHS CE, RoHS CE, RoHS * Different parameters on request ** Without condensation Design and specification of the described product(s) are subject to change without notice.

5 LaserDec CL200 - Dimensions -

6 LaserDec CL500 - Technical Data - CL500 CL500 HP CL500 HP - HS Standard High Performance High Sensitivity IMAGE CONVERTER Spectral sensitivity: 8µm - 12µm 8µm - 12µm 8µm - 12µm Clear aperture: =30mm =30mm =30mm Beam diameter (1/e 2 ): 1mm - 15mm 1mm - 15mm 1mm - 15mm Intensity range: 10W/cm W/cm 2 20W/cm W/cm 2 1W/cm 2-100W/cm 2 Input power (max): 450W 450W 100W With attenuation unit 0 : up to 2kW up to 2kW up to 1kW With attenuation unit 90 : up to 3kW up to 3kW up to 1.5kW Effective pixel size*: ~124µm ~62.5µm ~62.5µm CAMERA FEATURES Sensor: CCD CCD CCD Resolution*: 320 x 240pixel 640 x 480pixel 640 x 480pixel Bit depth (output): 14 Bit 14 Bit 14 Bit Frame rate: up to 20Hz up to 20Hz up to 20Hz Interface: FireWire 1394b / GigE FireWire 1394b / GigE FireWire 1394b / GigE Mode: cw or pulsed cw or pulsed cw or pulsed SPECIFICATIONS Mechanical dimensions (W x H x L): 340mm x 165mm x 92mm 340mm x 165mm x 92mm 340mm x 165mm x 92mm Weight: 3.3kg 3.4kg 3.5kg Electrical requirements: AC120V/240V; 48-63Hz; 570W AC120V/240V; 48-63Hz; 570W AC120V/240V; 48-63Hz; 320W Storage temperature**: 0 C +60 C 0 C +60 C 0 C +60 C Operating temperature**: +5 C +35 C +5 C +35 C +5 C +35 C Humidity: 20%...80% 20%...80% 20%...80% Regulations: CE, RoHS CE, RoHS CE, RoHS * Different parameters on request ** Without condensation Design and specification of the described product(s) are subject to change without notice.

7 LaserDec CL500 - Dimensions -

8 LaserDec CR200 - Technical Data - CR200 CR200 HP Standard High Performance IMAGE CONVERTER Spectral sensitivity: 1.5µm - 8µm 1.5µm - 8µm Clear aperture: =20mm =20mm Beam diameter (1/e 2 ): 1mm - 10mm 1mm - 10mm Intensity range: 10W/cm W/cm 2 15W/cm W/cm 2 Input power (max): 150W 150W Effective pixel size*: ~90µm ~45µm CAMERA FEATURES Sensor: CCD CCD Resolution*: 320 x 240pixel 640 x 480pixel Bit depth (output): 14 Bit 14 Bit Frame rate: up to 20Hz up to 20Hz Interface: FireWire 1394b / GigE FireWire 1394b / GigE Mode: cw or pulsed cw or pulsed SPECIFICATIONS Mechanical dimensions (W x H x L): 298mm x 141mm x 76mm 298mm x 141mm x 76mm Weight: 2.6kg 2.8kg Electrical requirements: AC120V/240V; 48-63Hz; 285W AC120V/240V; 48-63Hz; 285W Storage temperature**: 0 C +60 C 0 C +60 C Operating temperature**: +5 C +35 C +5 C +35 C Humidity: 20%...80% 20%...80% Regulations: CE, RoHS CE, RoHS * Different parameters on request ** Without condensation Design and specification of the described product(s) are subject to change without notice.

9 LaserDec CR200 - Dimensions -

10 Attenuation Unit 0 - Technical Data - The attenuation unit is based on a zinc selenide (ZnSe) beam slitter and can be mounted in four positions on the LaserDec aperture. It is designed for a 10 angle of incidence and can be used up to intensities of 4kW/cm². The absorbed heat is dissipated by cooling water whereby thermal lens effects are eliminated. The water-cooling allows the utilization of lasers up to powers of 2kW. To avoid interference patterns the beam splitter is designed as wedge angle. AU-05-0 AU-10-0 AU-15-0 AU-20-0 Spectral range * : 10.6µm 10.6µm 10.6µm 10.6µm Transmission rates * : T=5% T=10% T=15% T=20% Angle of incidence: Aperture: =25mm =25mm =25mm =25mm Beam diameter (1/e 2 ) LaserDec CL200: max. 10mm max. 10mm max. 10mm max. 10mm Beam diameter (1/e 2 ) LaserDec CL500: max. 15mm max. 15mm max. 15mm max. 15mm Wedge angle: 6-10min 6-10min 6-10min 6-10min Surface: S1=plan - 95%R S2=plan - AR S1=plan - 90%R S2=plan - AR S1=plan - 85%R S2=plan - AR S1=plan - 80%R S2=plan - AR Intensity (Imax): 4kW/cm 2 4kW/cm 2 4kW/cm 2 4kW/cm 2 Power (Pmax) LaserDec CL200: 2kW 2kW 1.5kW 1kW Power (Pmax) LaserDec CL500: 2kW 2kW 2kW 2kW Water-cooling: 2l/min / 2bar 2l/min / 2bar 2l/min / 2bar 2l/min / 2bar Hose diameter: OD=8mm OD=8mm OD=8mm OD=8mm * Different parameters on request Design and specification of the described product(s) are subject to change without notice.

11 Attenuation Unit 90 - Technical Data - The attenuation unit is based on a zinc selenide (ZnSe) beam slitter and can be mounted in four positions on the LaserDec aperture. It is designed for a 45 angle of incidence and can be used up to intensities of 5kW/cm². The absorbed heat is dissipated by cooling water whereby thermal lens effects are eliminated. The water-cooling allows the utilization of lasers up to powers of 3kW. To avoid interference patterns the beam splitter is designed as wedge angle. AU-SP-90 AU AU Spectral range * : 10.6µm 10.6µm 10.6µm Polarization: Polarization-dependent Polarization-independent Polarization-independent Reflection rates: RS=28% / RP=7.8% R=33.3% R=50% Angle of incidence: Aperture: =26mm =26mm =26mm Beam diameter (1/e 2 ) LaserDec CL200: max. 10mm max. 10mm max. 10mm Beam diameter (1/e 2 ) LaserDec CL500: max. 15mm max. 15mm max. 15mm Wedge angle: min 6-10min Surface: S1=plan - uncoated S2=plan - AR S1=plan %R S2=plan - AR S1=plan - 50%R S2=plan - AR Intensity (Imax): 5kW/cm 2 3kW/cm 2 3kW/cm 2 Power (Pmax) LaserDec CL200: 700W (RS) / 2.5kW (RP) 600W 400W Power (Pmax) LaserDec CL500: 1.7kW (RS) / 3kW (RP) 1.5kW 1kW Water-cooling: 2l/min / 2bar 2l/min / 2bar 2l/min / 2bar Hose diameter: OD=8mm OD=8mm OD=8mm * Different parameters on request Design and specification of the described product(s) are subject to change without notice.

12 Beam Reducer - Technical Data - The beam reducers are based on zinc selenide (ZnSe) lens elements with adjustable lens spacing. The large input aperture allows beam profiling of lasers with diameters up to 40mm with CINOGY s LaserDec systems. A high transmission rate >97% and a low wavefront distortion <1/4 Wave ensure beam reducing without loss. The beam reducers can be used up to intensities of 20kW/cm² for pulse wave and 1kW/cm² for continuous wave. They have one positive input lens and one negative output lens (Galilean telescope). BR-25-2x BR-50-2x BR-50-5x BR-75-5x Spectral range * : 10.6µm 10.6µm 10.6µm 10.6µm Ratio: 2x 2x 5x 5x Large aperture: 25mm 50mm 50mm 75mm Beam diameter (1/e²): max. 13mm max. 26mm max. 26mm max. 40mm Intensity (Imax) CL200: 1kW/cm 2-400W/cm 2 400W/cm 2 Intensity (Imax) CL500: - 1kW/cm 2 400W/cm 2 400W/cm 2 Coating damage threshold: 100MW/cm 2 100MW/cm 2 100MW/cm 2 100MW/cm 2 Dimensions (O.D. x L): 38.1mm x 83mm 69.9mm x 147mm 69.9mm x 147mm 85.7mm x 230mm * Different parameters on request Design and specification of the described product(s) are subject to change without notice.

13 Microscope Objective - Technical Data - The IR objective is an add-on to the standard LaserDec CL Beam Profiler. It is based on zinc selenide (ZnSe) and can be mounted on the LaserDec aperture. This special designed objective is optimized for focus spot measurements in the range of 100µm - 500µm up to 100W (cw) laser power. The focal plane is imaged with 35x magnification to the effective area of the LaserDec CL Beam Profiler. OB-IR-01 Spectral range * : 10.6µm Magnification: 35x Numerical aperture: 0.23 Focus size: CL200 series Focus size: CL500 series Resolution: <10µm Power (Pmax): <100W (depending on focus spot size) * Different parameters on request Design and specification of the described product(s) are subject to change without notice.

14 LASER BEAM PROFILER SOFTWARE Beam Profiler Software RayCi - Product Description - CINOGY Technologies beam profilers are available with the specifically designed analysis software, RayCi, which supports XP / Vista / Windows 7 / 8 operating systems. It is available as 32 Bit / 64 Bit version and can control several beam profiler cameras on a single computer simultaneously. XP / Vista / Windows 7 / 8 Pentium IV / AMD Processor (Dual / Quad Core) 512MB graphic, Open GL V1.4 (NVIDIA) 2GB RAM 500MB free memory PCI / PCIe slot USB ports CD / DVD-ROM drive Internet access for update request Due to its clearly designed menu structure, RayCi shows self-explanatory functions, which help the user to access quickly standard settings. Incomparable visualization modes, extensive analytical capabilities as well as new developed correction algorithms ensure the highest accuracy in laser beam analysis. A wide range of beam width techniques e.g. 2 nd Moment, Knife Edge, Moving Slit, Plateau and Gauss-Fit can be applied to determine quick and reliable standard beam parameters. The unique measurement tool enables the continuous monitoring of beam parameters, beam position and power density distribution. Moreover a new beam quality M 2 tool enables accurate beam quality analysis. The extraordinary graphical and analytical tool of RayCi can be used for live data (LiveMode) and stored data (SaveMode) simultaneously, while each mode has its own individual functions. This makes RayCi the most advanced analysis software on the market. Helpful features like AOI Tracking, AOI Optimization, Zoom Functions, Look-Up Tables, etc. simplify the laser beam analysis. RayCi is equipped with flexible data and image output capabilities. This permits the user to store data and images in the format that is compatible with their needs. A clearly arranged and printable protocol view displays the measurement parameters as well as the most important laser beam analysis results. CINOGY S laser beam profiler can easily be integrated in different automation systems and processes. The supplied Software Development Kit (SDK) based on a XML-rpc interface. The user can write programs in a number of platforms, such as Python, Visual Basic, LabVIEW, etc. which will remote-control the beam profiler.

UV-NIR LASER BEAM PROFILER

UV-NIR LASER BEAM PROFILER CinCam CCD Technical Data CCD1201 CCD1301 CCD2301 CCD2302 Standard Series Standard Series Standard Series Standard Series SENSOR DATA Format: 1/2 1/3 2/3 2/3 Active area (without cover glass): 6.5mm x

More information

Coherent Laser Measurement and Control Beam Diagnostics

Coherent Laser Measurement and Control Beam Diagnostics Coherent Laser Measurement and Control M 2 Propagation Analyzer Measurement and display of CW laser divergence, M 2 (or k) and astigmatism sizes 0.2 mm to 25 mm Wavelengths from 220 nm to 15 µm Determination

More information

Beam Splitters. Diameter ET Transmission Reflectance %

Beam Splitters. Diameter ET Transmission Reflectance % Beam Splitters Beam splitters allow a beam to be split into two beams of differing power, however, the most popular power split is 50:50 at a 45 incidence angle. The polarization needs to be considered

More information

Nikon COOLSCAN V ED Major Features

Nikon COOLSCAN V ED Major Features Nikon COOLSCAN V ED Major Features 4,000-dpi true optical-resolution scanning, 14-bit A/D converter featuring 16-/8-bit output for clear, colorful images Exclusive Scanner Nikkor ED high-performance lens

More information

Minimizes reflection losses from UV to IR; No optical losses due to multiple optical surfaces; Optional AR coating and wedge windows available.

Minimizes reflection losses from UV to IR; No optical losses due to multiple optical surfaces; Optional AR coating and wedge windows available. SOPHIA: 2048B The SOPHIA : 2048B camera from Princeton Instruments (PI) is fully integrated, ultra-low noise 2048 x 2048, 15 µm pixel CCD camera designed expressly for the most demanding quantitative scientific

More information

Beamscope-P8 Wavelength Range. Resolution ¼ - 45 ¼ - 45

Beamscope-P8 Wavelength Range. Resolution ¼ - 45 ¼ - 45 Scanning Slit System Beamscope-P8 Typical Applications: Laser / diode laser characterisation Laser assembly development, alignment, characterisation, production test & QA. Lasers and laser assemblies for

More information

Nikon SUPER COOLSCAN 5000 ED Major Features

Nikon SUPER COOLSCAN 5000 ED Major Features Nikon SUPER COOLSCAN 5000 ED Major Features 4,000-dpi true optical-resolution scanning, 16-bit A/D converter featuring 16-/8-bit output for crisp, color-true images Exclusive Scanner Nikkor ED high-performance

More information

1.2 BeamTrack Power / Position / Size Sensors

1.2 BeamTrack Power / Position / Size Sensors 1.2 BeamTrack Power / Position / Size Ophir now has the new BeamTrack line of thermal sensors that can measure beam position and beam size while measuring power. This innovative device will provide an

More information

Laser Speckle Reducer LSR-3000 Series

Laser Speckle Reducer LSR-3000 Series Laser Speckle Reducer LSR-3000 Series Speckle noise from a laser-based system is reduced by dynamically diffusing the laser beam. A diffuser is bonded to a thin elastic membrane, which includes four independent

More information

Beam Analysis BeamWatch Non-contact, Focus Spot Size and Position monitor for high power YAG, Diode and Fiber lasers. Disruptive Technology

Beam Analysis BeamWatch Non-contact, Focus Spot Size and Position monitor for high power YAG, Diode and Fiber lasers. Disruptive Technology 3.8 BeamWatch Non-contact, Focus Spot Size and Position monitor for high power YAG, Diode and Fiber lasers Instantly measure focus spot size Dynamically measure focal plane location during start-up From

More information

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs. 2D Color Analyzer Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs. Accurately and easily measures the distribution of luminance and chromaticity. The included

More information

Laser Speckle Reducer LSR-3000 Series

Laser Speckle Reducer LSR-3000 Series Datasheet: LSR-3000 Series Update: 06.08.2012 Copyright 2012 Optotune Laser Speckle Reducer LSR-3000 Series Speckle noise from a laser-based system is reduced by dynamically diffusing the laser beam. A

More information

Where Image Quality Begins

Where Image Quality Begins Where Image Quality Begins Filters are a Necessity Not an Accessory Inexpensive Insurance Policy for the System The most cost effective way to improve repeatability and stability in any machine vision

More information

Gentec Electro-Optics, Inc

Gentec Electro-Optics, Inc Gentec Electro-Optics, Inc. 2013. Accessories for Beam Diagnostics Revision 2.0 2 WARRANTY The Gentec-EO accessories for beam diagnostics carry a one-year warranty (from date of shipment) against material

More information

White Paper: Modifying Laser Beams No Way Around It, So Here s How

White Paper: Modifying Laser Beams No Way Around It, So Here s How White Paper: Modifying Laser Beams No Way Around It, So Here s How By John McCauley, Product Specialist, Ophir Photonics There are many applications for lasers in the world today with even more on the

More information

Gentec Electro-Optics, Inc

Gentec Electro-Optics, Inc Gentec Electro-Optics, Inc. 2013. Accessories for Beam Diagnostics Revision 1.2 2 WARRANTY The Gentec-EO accessories for beam diagnostics carry a one-year warranty (from date of shipment) against material

More information

ikon-m 934 DO Series

ikon-m 934 DO Series X-Ray diffraction pattern of the Synchrotron Soleil,France. Courtesy of Vincent Jacques Low Light Imaging X-Ray Cameras Features and Benefits Open front end 1 CF152 flange and knife-edge sealing provided

More information

How to Avoid Thermal Sensor Damage & Out of Tolerance Conditions

How to Avoid Thermal Sensor Damage & Out of Tolerance Conditions About Ophir-Spiricon With over 30 years of experience, the Ophir Photonics Group provides a complete line of instrumentation including power and energy meters, beam profilers, spectrum analyzers, and goniometric

More information

Specifications Summary. Register well depth (typical) Standard mode High Capacity mode High Sensitivity mode. Maximum spectra per sec 1,612

Specifications Summary. Register well depth (typical) Standard mode High Capacity mode High Sensitivity mode. Maximum spectra per sec 1,612 100 90 80 70 60 BU2 BU BV BRDD Spectroscopy QE (%) 50 40 FI 30 20 10 OE UV 0 200 300 400 500 600 700 800 900 1000 1100 1200 Wavelength (nm) Features and Benefits MultiMegahertz Readout High repetition

More information

Minimizes reflection losses from UV-IR; Optional AR coatings & wedge windows are available.

Minimizes reflection losses from UV-IR; Optional AR coatings & wedge windows are available. Now Powered by LightField PyLoN:2K 2048 x 512 The PyLoN :2K is a controllerless, cryogenically-cooled CCD camera designed for quantitative scientific spectroscopy applications demanding the highest possible

More information

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs. 2D Color Analyzer 8 Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs. Accurately and easily measures the distribution of luminance and chromaticity. Advanced

More information

SpectraPro 2150 Monochromators and Spectrographs

SpectraPro 2150 Monochromators and Spectrographs SpectraPro 215 Monochromators and Spectrographs SpectraPro 215 15 mm imaging spectrographs and monochromators from are the industry standard for researchers who demand the highest quality data. Acton monochromators

More information

BEAMAGE-3.0 KEY FEATURES BEAM DIAGNOSTICS AVAILABLE MODELS MAIN FUNCTIONS SEE ALSO ACCESSORIES. CMOS Beam Profiling Cameras

BEAMAGE-3.0 KEY FEATURES BEAM DIAGNOSTICS AVAILABLE MODELS MAIN FUNCTIONS SEE ALSO ACCESSORIES. CMOS Beam Profiling Cameras BEAM DIAGNOSTICS BEAM DIAGNOSTICS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER DETECTORS POWER DETECTORS ENERGY DETECTORS MONITORS CMOS Beam Profiling Cameras AVAILABLE MODELS

More information

BEAM PROFILING CAMERAS

BEAM PROFILING CAMERAS PRESENTATION CAMERAS PRESENTATION SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS MONITORS MAIN SPECIFICATIONS Wavelength Range BEAM PROFILING

More information

Nmark AGV-HP. High Accuracy, Thermally Stable Galvo Scanner

Nmark AGV-HP. High Accuracy, Thermally Stable Galvo Scanner Nmark AGV-HP High Accuracy, Thermally Stable Galvo Scanner Highest accuracy scanner available attains single-digit, micron-level accuracy over the field of view Optical feedback technology significantly

More information

Achieving 100,000 : 1 contrast measurement

Achieving 100,000 : 1 contrast measurement NEW Spectroradiometer Highly precise spectral radiance/chromaticity measurement possible from 0.003 cd/m 2 Achieving 100,000 : 1 contrast measurement World's top level capability to detect extremely low

More information

The new Konica Minolta DiMAGE Scan Dual IV film scanner

The new Konica Minolta DiMAGE Scan Dual IV film scanner The new Konica Minolta DiMAGE Scan Dual IV film scanner Mississauga, Ontario, January 7 th, 2004: Konica Minolta Camera, Inc. introduces the DiMAGE Scan Dual IV film scanner as a successor model of their

More information

Bandpass Edge Dichroic Notch & More

Bandpass Edge Dichroic Notch & More Edmund Optics BROCHURE Filters COPYRIGHT 217 EDMUND OPTICS, INC. ALL RIGHTS RESERVED 1/17 Bandpass Edge Dichroic Notch & More Contact us for a Stock or Custom Quote Today! USA: +1-856-547-3488 EUROPE:

More information

DV420 SPECTROSCOPY. issue 2 rev 1 page 1 of 5m. associated with LN2

DV420 SPECTROSCOPY.   issue 2 rev 1 page 1 of 5m. associated with LN2 SPECTROSCOPY Andor s DV420 CCD cameras offer the best price/performance for a wide range of spectroscopy applications. The 1024 x 256 array with 26µm 2 pixels offers the best dynamic range versus resolution.

More information

Infra Red Interferometers

Infra Red Interferometers Infra Red Interferometers for performance testing of infra-red materials and optical systems Specialist expertise in testing, analysis, design, development and manufacturing for Optical fabrication, Optical

More information

BEAMAGE KEY FEATURES AVAILABLE MODELS. CMOS Beam Profiling Cameras

BEAMAGE KEY FEATURES AVAILABLE MODELS. CMOS Beam Profiling Cameras BEAM DIAGNOS TICS Beam Profiling Cameras KEY FEATURES SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS MONITORS AVAILABLE MODELS Beamage-3.0

More information

Measuring Procedure the Principle. The laser beam is scanned by means of a specialized measuring tip within a 3D measurement cylinder.

Measuring Procedure the Principle. The laser beam is scanned by means of a specialized measuring tip within a 3D measurement cylinder. PRIMES FocusMonitor FM For different wavelengths pyroelectric detectors or photodiodes are used. The divergence of the focused laser beam of lasers is rather small. The relationship between the focal length

More information

ERS KEY FEATURES BEAM DIAGNOSTICS MAIN FUNCTIONS AVAILABLE MODEL. CMOS Beam Profiling Camera. 1 USB 3.0 for the Fastest Transfer Rates

ERS KEY FEATURES BEAM DIAGNOSTICS MAIN FUNCTIONS AVAILABLE MODEL. CMOS Beam Profiling Camera. 1 USB 3.0 for the Fastest Transfer Rates POWER DETECTORS ENERGY DETECTORS MONITORS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER DETECTORS CAMERA PROFIL- CMOS Beam Profiling Camera KEY FEATURES ERS 1 USB 3.0 for the

More information

Pulsed Laser Power Measurement Systems

Pulsed Laser Power Measurement Systems Pulsed Laser Power Measurement Systems Accurate, reproducible method of determining total laser and laser diode power Ideal for Beam Power Measurement Labsphere s Pulsed Laser Power Measurement Systems

More information

3.4 Introduction to Scanning-Slit Profilers

3.4 Introduction to Scanning-Slit Profilers 3.4 Introduction to Scanning-Slit Profilers The scanning slit beam profiler moves two narrow orthogonal slits in front of a linear photo-detector through the beam under analysis. Light passing through

More information

3.4 Introduction to Scanning-Slit Profilers

3.4 Introduction to Scanning-Slit Profilers 3.4 Introduction to Scanning-Slit Profilers The scanning slit beam profiler moves two narrow orthogonal slits in front of a linear photo-detector through the beam under analysis. Light passing through

More information

Microscope-Spectrometer

Microscope-Spectrometer 20 Micro-spectrometer ToupTek s spectrometer is applicable for spectral detection within the wavelength range between 200nm and 1100nm. Due to their high stability and performance, these portable instruments

More information

CS-2000/2000A. Spectroradiometer NEW

CS-2000/2000A. Spectroradiometer NEW Spectroradiometer NEW CS-000/000A The world's top-level capability spectroradiometers make further advances with addition of second model to lineup. World's top level capability to detect extremely low

More information

AxioCam MRc 5 A World of Digital Possibilities

AxioCam MRc 5 A World of Digital Possibilities Microscopy from Carl Zeiss AxioCam MRc 5 A World of Digital Possibilities More flexibility and more performance in microscope camera technology Impressive Performance A trend setter in digital microscopy,

More information

100 khz and 2 MHz digitization rates Choose low speed digitization for low noise or high speed for fast spectral acquisition.

100 khz and 2 MHz digitization rates Choose low speed digitization for low noise or high speed for fast spectral acquisition. Now Powered by LightField PIXIS: 1 134 x 1 The PIXIS series from Princeton Instruments (PI) are fully integrated, low noise cameras with a 134 pixel format designed for quantitative scientific optical

More information

Power Sensors Introduction

Power Sensors Introduction Introduction Introduction and Selection Charts & Coherent uses three primary coatings to capture the incident radiation on our thermal sensors. The specifications for each sensor list which coating is

More information

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup. Spectroradiometer /000A The world's top-level capability spectroradiometers make further advances with addition of second model to lineup. World's top level capability to detect extremely low luminance

More information

HS-1800 Specifications

HS-1800 Specifications Film scanner HS-1800 Specifications Specifications Example USB 2.0 Scanner PC G089231 Overall dimensions Weight Light source LED Class Film size Film type Film carrier (option) See Dimensions. Approx.

More information

DataRay Software. Feature Highlights. Beam Profiling Camera Based WinCamDTM Series. Software Aperture/ISO measurements

DataRay Software. Feature Highlights. Beam Profiling Camera Based WinCamDTM Series. Software Aperture/ISO measurements Beam Profiling Camera Based WinCamDTM Series DataRay Software DataRay s full-featured, easy to use software is specifically designed to enable quick and accurate laser beam profiling. The software, which

More information

Information & Instructions

Information & Instructions KEY FEATURES 1. USB 3.0 For the Fastest Transfer Rates Up to 10X faster than regular USB 2.0 connections (also USB 2.0 compatible) 2. High Resolution 4.2 MegaPixels resolution gives accurate profile measurements

More information

Nmark AGV-HP. High Accuracy, Thermally Stable Galvo Scanner

Nmark AGV-HP. High Accuracy, Thermally Stable Galvo Scanner Nmark AGV-HP Galvanometer Nmark AGV-HP High Accuracy, Thermally Stable Galvo Scanner Highest accuracy scanner available attains single-digit, micron-level accuracy over the field of view Optical feedback

More information

DU-897 (back illuminated)

DU-897 (back illuminated) IMAGING Andor s ixon EM + DU-897 back illuminated EMCCD has single photon detection capability without an image intensifier, combined with greater than 90% QE of a back-illuminated sensor. Containing a

More information

Pyroelectric, Photodiode and RP Heads for Repetitive Energy Measurements

Pyroelectric, Photodiode and RP Heads for Repetitive Energy Measurements Pyroelectric, Photodiode and RP Heads for Repetitive Energy Measurements Pyroelectric and Photodiode Heads RP Heads For latest updates please visit our website: www.ophiropt.com 1 Pyroelectric and Photodiode

More information

TECHNICAL DATA OPTIV CLASSIC 432

TECHNICAL DATA OPTIV CLASSIC 432 TECHNICAL DATA OPTIV CLASSIC 432 Technical Data Product description The Optiv Classic 432 combines optical and tactile measurement in one system (optional touchtrigger probe). The system supports multi-sensor

More information

COMPACT Diode Laser System (Water-Cooled)

COMPACT Diode Laser System (Water-Cooled) COMPACT Diode Laser System (Water-Cooled) Easy-to-integrate CW system consists of a compact 19 (11HU including water-air-chiller), rack-mountable chassis and metal-armored fiber. Can be combined with DILAS

More information

Optional AR coating and wedge windows are available

Optional AR coating and wedge windows are available TThe PIXIS series from Princeton Instruments (PI) are fully integrated, low noise cameras designed for quantitative scientific imaging optical spectroscopy applications. Designed utilizing PI s exclusive

More information

Miniaturized Laser Speckle Reducer OEM Series

Miniaturized Laser Speckle Reducer OEM Series Miniaturized Laser Speckle Reducer OEM Series Speckle noise from a laser-based system is reduced by dynamically diffusing the laser beam. A diffuser is bonded to a thin elastic membrane, which includes

More information

Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.

Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming. NIRvana: 640LN The NIRvana: 640LN from Princeton Instruments is a scientific-grade, deep-cooled, large format InGaAs camera for low-light scientific SWIR imaging and spectroscopy applications. The camera

More information

OBIS CellX. The Universal Light Engine FEATURES

OBIS CellX. The Universal Light Engine FEATURES OBIS CellX The Universal Light Engine OBIS CellX is a multi-wavelength platform for use as the laser excitation Light Engine in applications requiring or laser wavelengths from a single module. CellX delivers

More information

NL300 series. Compact Flash-Lamp Pumped Q-switched Nd:YAG Lasers FEATURES APPLICATIONS NANOSECOND LASERS

NL300 series. Compact Flash-Lamp Pumped Q-switched Nd:YAG Lasers FEATURES APPLICATIONS NANOSECOND LASERS NL200 NL210 NL230 NL300 NL740 electro-optically Q-switched nanosecond Nd:YAG lasers produce high energy pulses with 3 6 ns duration. Pulse repetition rate can be selected in range of 5 20 Hz. NL30 HT models

More information

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser. BTS2048-BS http://www.gigahertz-optik.de/en-us/product/bts2048-bs Product tags: VIS, Spectral Data, Industrial Applications, Laser Gigahertz-Optik GmbH 1/6 Description BTS2048-BS CCD spectroradiometer

More information

X-Ray diffraction pattern of the Synchrotron Soleil,France. Courtesy of Vincent Jacques. Direct Detection X-Ray Imaging. Specifications Summary

X-Ray diffraction pattern of the Synchrotron Soleil,France. Courtesy of Vincent Jacques. Direct Detection X-Ray Imaging. Specifications Summary X-Ray diffraction pattern of the Synchrotron Soleil,France. Courtesy of Vincent Jacques Low Light Imaging X-Ray Cameras Features and Benefits Open front end 1 CF152 flange and knife-edge sealing provided

More information

Filters for Dual Band Infrared Imagers

Filters for Dual Band Infrared Imagers Filters for Dual Band Infrared Imagers Thomas D. Rahmlow, Jr.* a, Jeanne E. Lazo-Wasem a, Scott Wilkinson b, and Flemming Tinker c a Rugate Technologies, Inc., 353 Christian Street, Oxford, CT 6478; b

More information

Beam Expander (4) Substituting Equation (1) into Equation (5), the following expression can be obtained

Beam Expander (4) Substituting Equation (1) into Equation (5), the following expression can be obtained Beam Expander We manufacture a variety of laser beam expanders to suit most laser types, from small waveguide lasers up to multi-kilowatt industrial lasers. There is also a modular range for experimental

More information

OPTIV CLASSIC 321 GL TECHNICAL DATA

OPTIV CLASSIC 321 GL TECHNICAL DATA OPTIV CLASSIC 321 GL TECHNICAL DATA TECHNICAL DATA Product description The Optiv Classic 321 GL offers an innovative design for non-contact measurement. The benchtop video-based measuring machine is equipped

More information

ULS24 Frequently Asked Questions

ULS24 Frequently Asked Questions List of Questions 1 1. What type of lens and filters are recommended for ULS24, where can we source these components?... 3 2. Are filters needed for fluorescence and chemiluminescence imaging, what types

More information

The RSH Catalogue. Laser Optics & Lenses

The RSH Catalogue. Laser Optics & Lenses The RSH Catalogue Laser Optics & Lenses 2013 2014 1 Company Profile RSH Optronics, Headquartered in Ajmer, Rajasthan, India, is the leading supplier & manufacturer for Photonics Products (Optics, Laser

More information

Imaging Photometer and Colorimeter

Imaging Photometer and Colorimeter W E B R I N G Q U A L I T Y T O L I G H T. /XPL&DP Imaging Photometer and Colorimeter Two models available (photometer and colorimetry camera) 1280 x 1000 pixels resolution Measuring range 0.02 to 200,000

More information

End Capped High Power Assemblies

End Capped High Power Assemblies Fiberguide s end capped fiber optic assemblies allow the user to achieve higher coupled power into a fiber core by reducing the power density at the air/ silica interface, commonly the point of laser damage.

More information

Spotlight 150 and 200 FT-IR Microscopy Systems

Spotlight 150 and 200 FT-IR Microscopy Systems S P E C I F I C A T I O N S Spotlight 150 and 200 FT-IR Microscopy Systems FT-IR Microscopy Spotlight 200 with Frontier FT-IR Spectrometer Introduction PerkinElmer Spotlight FT-IR Microscopy Systems are

More information

Digital Microscope. User Manual

Digital Microscope. User Manual Digital Microscope User Manual Features The digital microscope provides 10~200X adjustable magnification range. The build-in high-performance white LED can illuminate the object without using any auxiliary

More information

Beam Analysis NanoScan 2. Scanning Slit Beam Profiler For High Accuracy Dimensional Measurement. Capabilities.

Beam Analysis NanoScan 2. Scanning Slit Beam Profiler For High Accuracy Dimensional Measurement. Capabilities. NanoScan 2 Scanning Slit Beam Profiler For High Accuracy Dimensional Measurement NanoScan 2 combines the convenience and portability of direct USB connectivity with the speed, accuracy, and dynamic range

More information

High Power Supercontinuum Fiber Laser Series. Visible Power [W]

High Power Supercontinuum Fiber Laser Series. Visible Power [W] Visible Power [W] Crystal Fibre aerolase Koheras SuperK SuperK EXTREME High Power Supercontinuum Fiber Laser Series 400-2400nm white light single mode spectrum Highest visible power Unsurpassed reliability

More information

PICO MASTER 200. UV direct laser writer for maskless lithography

PICO MASTER 200. UV direct laser writer for maskless lithography PICO MASTER 200 UV direct laser writer for maskless lithography 4PICO B.V. Jan Tinbergenstraat 4b 5491 DC Sint-Oedenrode The Netherlands Tel: +31 413 490708 WWW.4PICO.NL 1. Introduction The PicoMaster

More information

Technical Benefits of the

Technical Benefits of the innovation in microvascular assessment Technical Benefits of the Moor Instruments moorflpi-2 moorflpi-2 More Info: Measurement Principle laser speckle contrast analysis Measurement 85nm Laser Wavelength

More information

Thermal Heads for Power and Single-Shot Energy - mw to KW, mj to 300J

Thermal Heads for Power and Single-Shot Energy - mw to KW, mj to 300J Thermal Heads for Power and Single-Shot Energy - mw to KW, mj to 300J The highest damage threshold in the industry Models for 1500W, 5000W and 10KW for high power laser measurement LP coating that can

More information

OEM Solutions POWER PROBES OEM SOLUTIONS USB/RS232 SENSORS MONITORS & SW

OEM Solutions POWER PROBES OEM SOLUTIONS USB/RS232 SENSORS MONITORS & SW OEM Solutions POWER PROBES OEM SOLUTIONS USB/RS232 MONITORS & SW Via Burona, 51 - Vimodrone (Milano) - ITALY 95 OEM and Custom Products POWER PROBES OEM SOLUTIONS USB/RS232 MONITORS & SW A customer-driven

More information

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e - Apogee Alta Series System Features 1 High Resolution Sensor 1.0 Megapixel sensor with 13 mm pixels delivers a large field of view with high resolution. Programmable TE cooling down to 50 o C below ambient

More information

Choosing the Best Optical Filter for Your Application. Georgy Das Midwest Optical Systems, Inc.

Choosing the Best Optical Filter for Your Application. Georgy Das Midwest Optical Systems, Inc. Choosing the Best Optical Filter for Your Application Georgy Das Midwest Optical Systems, Inc. Filters are a Necessity, Not an Accessory. Key Terms Transmission (%) 100 90 80 70 60 50 40 30 20 10 OUT-OF-BAND

More information

MicroSpot FOCUSING OBJECTIVES

MicroSpot FOCUSING OBJECTIVES OFR P R E C I S I O N O P T I C A L P R O D U C T S MicroSpot FOCUSING OBJECTIVES APPLICATIONS Micromachining Microlithography Laser scribing Photoablation MAJOR FEATURES For UV excimer & high-power YAG

More information

ixon Specifications Summary Active pixels 1024 x 1024 Active area pixel well depth 90,000 e - Gain register pixel well depth 730,000 e -

ixon Specifications Summary Active pixels 1024 x 1024 Active area pixel well depth 90,000 e - Gain register pixel well depth 730,000 e - Features and Benefits 13.3 x 13.3 mm sensor Largest Field of View EMCCD TE cooling to -95 C Critical for elimination of dark current detection limit OptAcquire Optimize the highly flexible ixon 3 for different

More information

Miniaturized Laser Speckle Reducer OEM Series

Miniaturized Laser Speckle Reducer OEM Series Miniaturized Laser Speckle Reducer OEM Series Speckle noise from a laser-based system is reduced by dynamically diffusing the laser beam. A diffuser is bonded to a thin elastic membrane, which includes

More information

Development and Applications of a Sample Compartment FTIR Microscope

Development and Applications of a Sample Compartment FTIR Microscope Application Note Development and Applications of a Sample Since the early to mid-1940 s, scientists using infrared spectroscopy have been trying to obtain spectral data from ever smaller samples. Starting

More information

TECHNICAL DATA. OPTIV CLASSIC 322 Version 3/2013

TECHNICAL DATA. OPTIV CLASSIC 322 Version 3/2013 TECHNICAL DATA OPTIV CLASSIC 322 Version 3/2013 Technical Data Product description The Optiv Classic 322 combines optical and tactile measurement in one system (optional touchtrigger probe). The system

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Electric and Magnetic Field Measurement For Isotropic Measurement of Magnetic and Electric Fields Evaluation of Field

More information

Infrared wire grid polarizers: metrology, modeling, and laser damage threshold

Infrared wire grid polarizers: metrology, modeling, and laser damage threshold Infrared wire grid polarizers: metrology, modeling, and laser damage threshold Matthew George, Bin Wang, Jonathon Bergquist, Rumyana Petrova, Eric Gardner Moxtek Inc. Calcon 2013 Wire Grid Polarizer (WGP)

More information

Optical Components. Table of Contents. Mirrors. Windows & Filters

Optical Components. Table of Contents. Mirrors. Windows & Filters Optical Components Mirrors Polarizing Optics UV & IR Optics High Reflectivity...1.3 Laser Line...1.3 Broadband...1.3 Partial Reflecting...1.4 Laser Harmonic Separators...1.4 Anti-Reflection...1.5 Laser

More information

Retina 400 THE SIMPLE AND FLEXIBLE SOLUTION FOR HIGH DEFINITION RETINAL IMAGERY NON-MYDRIATIC RETINAL CAMERA C/D AUTO 60 H X 45 V LED. 2,2 mm.

Retina 400 THE SIMPLE AND FLEXIBLE SOLUTION FOR HIGH DEFINITION RETINAL IMAGERY NON-MYDRIATIC RETINAL CAMERA C/D AUTO 60 H X 45 V LED. 2,2 mm. Retina 400 THE SIMPLE AND FLEXIBLE SOLUTION FOR HIGH DEFINITION RETINAL IMAGERY Retina 400 NON-MYDRIATIC RETINAL CAMERA 60 H X 45 V 2,2 mm LED C/D AUTO Auto Cup-to-disc 5 MP photo THE SIMPLE AND FLEXIBLE

More information

NOVA S12. Compact and versatile high performance camera system. 1-Megapixel CMOS Image Sensor: 1024 x 1024 pixels at 12,800fps

NOVA S12. Compact and versatile high performance camera system. 1-Megapixel CMOS Image Sensor: 1024 x 1024 pixels at 12,800fps NOVA S12 1-Megapixel CMOS Image Sensor: 1024 x 1024 pixels at 12,800fps Maximum Frame Rate: 1,000,000fps Class Leading Light Sensitivity: ISO 12232 Ssat Standard ISO 64,000 monochrome ISO 16,000 color

More information

Spectrolab in Optical Microscopy USB Digital Cameras CAT WCAM Series WIFI Camera

Spectrolab in Optical Microscopy USB Digital Cameras CAT WCAM Series WIFI Camera Spectrolab in Optical Microscopy USB Digital Cameras CAT 701110 WCAM Series WIFI Camera 1 Product Description The T-Tek WCAM series camera is a C-mount digital camera that attaches to the eyepiece of a

More information

BaySpec SuperGamut OEM

BaySpec SuperGamut OEM BaySpec SuperGamut OEM Spectrographs & Spectrometers RUGGED SOLID STATE HIGH RESOLUTION OPTIMIZED COOLING COST EFFECTIVE HIGH THROUGHPUT www.bayspec.com Specifications Model UV-NIR VIS-NIR NIR 900-1700nm

More information

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope Kenichi Ikeda 1, Hideyuki Kotaki 1 ' 2 and Kazuhisa Nakajima 1 ' 2 ' 3 1 Graduate University for Advanced

More information

Current Technology of Laser Beam Profile Measurements

Current Technology of Laser Beam Profile Measurements Current Technology of Laser Beam Profile Measurements Carlos B. Roundy, Ph.D. Ophir-Spiricon Inc. Logan, UT 84341 Phone: (435) 753-3729, Fax: (435) 753-5231, E-mail: sales@ophir-spiricon.com 1. Introduction

More information

Oriel MS260i TM 1/4 m Imaging Spectrograph

Oriel MS260i TM 1/4 m Imaging Spectrograph Oriel MS260i TM 1/4 m Imaging Spectrograph MS260i Spectrograph with 3 Track Fiber on input and InstaSpec CCD on output. The MS260i 1 4 m Imaging Spectrographs are economical, fully automated, multi-grating

More information

Soft X-rays Hard X-rays. Specifications Summary. Active pixels 1024 x Pixel size (W x H) 13 x 13 µm

Soft X-rays Hard X-rays. Specifications Summary. Active pixels 1024 x Pixel size (W x H) 13 x 13 µm Photon Energy 10eV 100eV 1keV 10keV 100keV Soft X-rays Hard X-rays YEA VACUUM WAANTY High Energy Detection Features and Benefits Standalone Beryllium window 1 200 µm thick Beryllium foil window as standard

More information

Hartmann Sensor Manual

Hartmann Sensor Manual Hartmann Sensor Manual 2021 Girard Blvd. Suite 150 Albuquerque, NM 87106 (505) 245-9970 x184 www.aos-llc.com 1 Table of Contents 1 Introduction... 3 1.1 Device Operation... 3 1.2 Limitations of Hartmann

More information

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy Digital Cameras for Microscopy Camera Overview For Materials Science Microscopes Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis Passionate about Imaging: Olympus Digital

More information

Specifications. Offers the best spatial resolution for multi-stripe spectroscopy. Provides the user the choice of either high accuracy slit mechanism

Specifications. Offers the best spatial resolution for multi-stripe spectroscopy. Provides the user the choice of either high accuracy slit mechanism SpectraPro Series Monochromators and Spectrographs The PI/Acton SpectraPro Series imaging spectrographs and monochromators represent the latest advance in the industry-standard SpectraPro family. The SpectraPro

More information

Nmark AGV-HPO. High Accuracy, Open Frame, Thermally Stable Galvo Scanner. Highest accuracy scanner available attains singledigit,

Nmark AGV-HPO. High Accuracy, Open Frame, Thermally Stable Galvo Scanner. Highest accuracy scanner available attains singledigit, Nmark AGV-HPO Galvanometer Nmark AGV-HPO High Accuracy, Open Frame, Thermally Stable Galvo Scanner Highest accuracy scanner available attains singledigit, micron-level accuracy over the field of view Optical

More information

KNIFE-EDGE RIGHT-ANGLE PRISM MIRRORS

KNIFE-EDGE RIGHT-ANGLE PRISM MIRRORS KNIFE-EDGE RIGHT-ANGLE PRISM MIRRORS Precision Cut Prisms Feature Bevel-Free 90 Angle Dielectric, Silver, Gold, and Aluminum Coatings Available 25 mm x 25 mm Faces Application Idea MRAK25-M01 Mounted on

More information

Beamage User Manual Revision 10 0

Beamage User Manual Revision 10 0 Beamage User Manual Revision 10 0 a Beamage User Manual Revision 12 i WARRANTY First Year Warranty The Gentec-EO Beamage series beam profiler carries a one-year warranty (from date of shipment) against

More information

CUBE. Diode Laser System FEATURES

CUBE. Diode Laser System FEATURES CUBE Diode Laser System The Coherent CUBE laser is a compact all-in-one laser system. CUBE lasers offer wavelengths from 75 nm to 70 nm with output power as high as 00 mw. Based on laser diode technologies

More information

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy Digital Cameras for Microscopy Camera Overview For Materials Science Microscopes Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis Passionate about Imaging: Olympus Digital

More information

improved stability (compared with

improved stability (compared with Picosecond Tunable Systems Nanosecond Lasers NT230 SERIES NT230 series lasers deliver high up to 10 mj energy pulses at 100 Hz pulse repetition rate, tunable over a broad spectral range. Integrated into

More information

Section lll: SM Series Spectrometer. ometers SPECTRAL PRODUCTS

Section lll: SM Series Spectrometer. ometers SPECTRAL PRODUCTS Section lll: SM Series ometers SPECTROMETERS SM200 OEM Packaged Fiber Optic CCD SM240 Hand-Held CCD SM241 Near Infrared Enhanced CCD AD300 Back Thinned CCD Tunable, TE Cooled SM300 Fluorencenced/Raman

More information