Rendering and Documenting Light

Size: px
Start display at page:

Download "Rendering and Documenting Light"

Transcription

1 Rendering Light Light and Air 1

2 Light and Air 4 2

3 Compositions of Light the development of a concept What Is The Desired Look? Light Mapping Direction of Light Painting with Light Light Mapping use a number scale to define bright to dark Bright Mid Dim

4 Painting with Light use a values of white or color to define layers of light sparkle focus ambient Direction of Light use arrows to define direction or distribution of light 4

5 Direction of Light Light and Air 5

6 Documenting Light Documenting Light 6

7 Documenting Light Documenting Light 7

8

9

10

11 11

12 12

13 Documenting A Lighting Plan Concept Drawing / Documentation Layout Symbols Fixture Specifications Fixture Descriptions Fixture Cuts / Mnfrs Submittals Fixture Details 13

14 Documenting A Lighting Plan Documentation Layout Documenting A Lighting Plan Documentation Layout 14

15 Documenting A Lighting Plan Defining light fixtures locations Documenting A Lighting Plan. Diagram Method Pendant Wall Washers Table Lamp 15

16 Documenting A Lighting Plan. Legend Method Legend: Pendant Wall Washers Table Lamp Documenting A Lighting Plan.. Type Method Fixture Types: F1 Pendant F2 F3 F1 F2 F2 F2 F2 Wall Washers F3 Table Lamp 16

17 Documenting A Lighting Plan.. Type Method Fixture Specification Fixture Types: F1 Pendant F2 F3 F1 F2 F2 F2 F2 Wall Washers F3 Table Lamp Documenting A Lighting Plan Fixture Specifications Written Documentation to Describe Fixture Location, Size, Performance, Source, etc. Manufacture!!!! Keyed to a Layout or Plan Type Designations Fixture Cuts Manufactures Catalog Cuts or Submittals Details 17

18 Documenting A Lighting Plan Graphics / Symbols Downlight Accent Wall Wash Wall Bracket or Sconce Ceiling Light Graphic to Define Location Floor, Walls, Ceiling (Solid or Dashed) Drawn to Scale and Shape Descriptive of the Type of Fixture Downlight, Pendant, Floor Lamp Keyed to Legend or Fixture Specification (aka Schedule) Pendant 18

19 19

20 Documenting Light Concepts 20

21 21

22 Documenting A Lighting Plan: Specifications Documenting A Lighting Plan: Specifications 22

23 Documenting A Lighting Plan: Specifications Documenting A Lighting Plan: Specifications 23

24 Type Designations (RS Lighting Design) X B A - 1 Optional for Exterior Fixtures Function Source (Lamp) Number A Accent Light B Bracket/Sconce C Ceiling Light D Downlight F Floodlight K Other L Landscape P Pendant R Cove S Socket Strip/Channel T Task / Table Lamp U Uplight / Indirect W Wall Wash Y Track Fixture A Arbitrary (Incand) C Compact Flour. D Diode (LED) F Fluorescent (Tubular) H High Pressure Sodium I Induction L Low Voltage M Metal Halide N Neon P Parabolic Q Quartz Halogen Used to identify size, wattage, series, etc. Other Misc: BO Bollard CU Custom DS Designer Select EX Existing YY Track FC Fluor. Cove Documenting Light Concepts 24

25 Documenting Light Concepts 25

26 26

27 Documenting Light Concepts Documenting Light Concepts 27

28 Documenting Light Concepts Documenting Light Concepts 28

29 Documenting Light Concepts Documenting Light Concepts 29

30 Documenting Light Concepts Documenting Light Concepts 30

31 Documenting Light Concepts Documenting Light Concepts 31

32 Documenting Light Concepts Downlights Over Table - Cove Over Table Downlights At Circulation Uplights On top of Banquets Documenting Light Concepts 32

33 Documenting Light Concepts 10 ft ceiling 10 ft ceiling 8 ft spacing lamp cut-off creates shadow vertical partition 10 ft ceiling 10 ft ceiling 10 ft spacing lamp cut-off creates shadow vertical partition 33

34 10 ft ceiling 2x2 Parabolic 2x40CF 8 ft x 8 ft Spacing 36 ft x 36 ft Room 10 ft ceiling Alternate Fixture 2x40CF 8 ft x 8 ft Spacing 36 ft x 36 ft Room 34

35 35

36 36

37 37

38 38

39 39

40 40

41 41

42 42

43 43

44 44

45 45

46 46

47 47

48 48

49 49

50 50

51 VRay Renderings Documenting Light Concepts 51

Rendering and Documenting Light. Rendering Light. Light and Air

Rendering and Documenting Light. Rendering Light. Light and Air Rendering Light Light and Air 1 Light and Air Light and Air 2 Documenting Light Documenting Light 3 Documenting Light Documenting Light 4 Documenting Light Concepts Documenting Light Concepts 5 6 Documenting

More information

Rendering and Documenting Light

Rendering and Documenting Light Rendering Light Concept Drawing / Documentation Layout Symbols Fixture Specifications Fixture Descriptions Fixture Cuts / Mnfrs Submittals Fixture Details Light and Air Light and Air 1 Light and Air Documenting

More information

Use timers, motion detectors, remote controls, and photocells to reduce waste.

Use timers, motion detectors, remote controls, and photocells to reduce waste. Exterior Exterior luminaires include large-area flood and small-area, landscape, and accent luminaires. They illuminate building facades, pathways, and landscapes and can provide lighting for safety, security,

More information

NOT SO SCARY LIGHTING MATH NOT SO SCARY LIGHTING MATH

NOT SO SCARY LIGHTING MATH NOT SO SCARY LIGHTING MATH NOT SO SCARY LIGHTING MATH NOT SO SCARY LIGHTING MATH The importance of Lighting Math: Calculations can determine the light levels Calculations can determine the required quantity of fixtures Calculations

More information

Turtle Friendly Lighting: Technical Advice Note

Turtle Friendly Lighting: Technical Advice Note Turtle Friendly Lighting: Technical Advice Note How to develop a sea turtle lighting plan Beachfront lighting principles Beachfront lighting specifications March 2018 Guidance on How to Develop a Sea Turtle

More information

NOT SO SCARY LIGHTING MATH

NOT SO SCARY LIGHTING MATH NOT SO SCARY LIGHTING MATH Methods to Calculate Light Point-by by-point Direct Illumination from a Fixture or Lamp You need. Photometry Distances from Fixture or Lamp Lumen Method Average Light Level in

More information

NOT SO SCARY LIGHTING MATH

NOT SO SCARY LIGHTING MATH NOT SO SCARY LIGHTING MATH Light The Foot-candle 1 foot 1 fc The direct illumination from one candle placed at a distance of one foot from a surface is defined as. 1 foot-candle (abbreviation = fc) Foot-candle

More information

The Bahen Centre for Information Technology. Lecture Hall Lighting Redesign. Introduction. University of Toronto ~ Toronto, Ontario, Canada

The Bahen Centre for Information Technology. Lecture Hall Lighting Redesign. Introduction. University of Toronto ~ Toronto, Ontario, Canada Lecture Hall Lighting Redesign downlight system, and the other will be an indirect pendant mounted lighting system. Figure 5.1 ~ Ground floor plan; Lecture hall location with respect to the entire building

More information

INDEPENDENCE VISITOR CENTER PHILADELPHIA, PA

INDEPENDENCE VISITOR CENTER PHILADELPHIA, PA The theater is located off the main hall of the Independence Visitor Center as seen in Figure 5.1. This theater is primarily used for watching movies having to do with the history of Philadelphia and Pennsylvania.

More information

An Introduction to Interior Lighting Design

An Introduction to Interior Lighting Design An Introduction to Interior Lighting Design G u y e r P a r t n e r s 4 4 2 4 0 C l u b h o u s e D r i v e E l M a c e r o, C A 9 5 6 1 8 ( 5 3 0 ) 7 7 5 8-6 6 3 7 j p g u y e r @ p a c b e l l. n e t

More information

NOT SO SCARY LIGHTING MATH

NOT SO SCARY LIGHTING MATH NOT SO SCARY LIGHTING MATH Measuring Light / Light Metrics Energy Watts and Codes Illumination Light Levels Brightness 1 Lighting Needs Power: Electrical Systems 1 Lighting Needs Power: Wires Distribute

More information

Northwest façade of building

Northwest façade of building Northwest façade of building North West Lighting The exterior space to be re-designed is composed of the north and west facades of the library. For this area, the building, using the symbol of the sun,

More information

Second Floor Circulation

Second Floor Circulation Second Floor Circulation Introduction As you enter Redifer commons the first space you come to is the vestibule. From the vestibule you can proceed into Louie s or through a set of doors into the Lobby.

More information

Microfilm and Reading Area

Microfilm and Reading Area Lighting Depth Depth Analysis: Lighting Design Lighting design is not just the placement of lights, but the concept and feeling it portrays as well. ASHRAE 90.1 and LEED both have to be observed, while

More information

Lighting Depth: Physical Therapy Suite Franklin Care Center, Franklin Lakes, NJ

Lighting Depth: Physical Therapy Suite Franklin Care Center, Franklin Lakes, NJ Physical Therapy Suite Overview: The physical therapy suite will be used by the patients for physical rehabilitation. It is similar to a small gym with exercise mats, bikes, a treadmill, stairs, parallel

More information

1.4 Rollins Center Performance Hall

1.4 Rollins Center Performance Hall 1.4 Rollins Center Performance Hall The Rollins Center is the name of the multi-purpose performance hall housed inside of Dover Downs. The performance hall is one of the highlights of Dover Downs. It is

More information

FWC SEA TURTLE LIGHTING GUIDELINES

FWC SEA TURTLE LIGHTING GUIDELINES FWC SEA TURTLE LIGHTING GUIDELINES These guidelines provide general information for all property owners living adjacent to sea turtle nesting beaches, but they are specifically designed to help property

More information

CMGT 352 Electrical Estimating Discussion #03 Commercial Building Electrical Systems Lighting. Lighting Terminology

CMGT 352 Electrical Estimating Discussion #03 Commercial Building Electrical Systems Lighting. Lighting Terminology CMGT 352 Electrical Estimating Discussion #03 Commercial Building Electrical Systems Lighting Lighting Terminology Lamp Types Light Emitting Diode - LED Fluorescent - FL Compact Fluorescent (CFL) Incandescent

More information

Furniture or Cabinet-Integrated

Furniture or Cabinet-Integrated Furniture or Cabinet-Integrated Many times, furniture, cabinetry, and appliances for homes include lighting elements. Included are lighting for medicine cabinets, shelves or display cabinets, under-cabinet,

More information

RSB-RCS/L SERIES The RSB-RCS/L Series rectangular shoebox is offered in a variety of lighting distributions with sharp cutoff to meet the challenging demands of today s site lighting projects. Fixture

More information

Westinghouse Range of Lamps includes: Compact Fluorescent Lamps High Intensity Discharge Lamps (HID) Halogen Fluorescent Lamps LED

Westinghouse Range of Lamps includes: Compact Fluorescent Lamps High Intensity Discharge Lamps (HID) Halogen Fluorescent Lamps LED GAL Lighting utilizes state of the art manufacturing technology and raw material sourced from reputed international suppliers, thereby ensuring top quality products. This is evident from the numerous international

More information

Light In Architecture

Light In Architecture Designing with Light Light plays a central role in the design of a visual environment. The architecture, people and objects are all made visible by the lighting. Light influences our well-being, the aesthetic

More information

Lighting Design Basics

Lighting Design Basics Lighting Design Basics Based on the Book by Mark Karlen and James Benya, Wiley and Sons, 2004 Presented by NKBA and Benya Lighting James Robert Benya, PE, FIES, IALD, LC BENYA LIGHTING DESIGN Portland,

More information

Energy and Calculating Light. Lighting Needs Power: Electrical Systems. Lighting Needs Power: Wires Distribute Electricity

Energy and Calculating Light. Lighting Needs Power: Electrical Systems. Lighting Needs Power: Wires Distribute Electricity Lighting Needs Power: Electrical Systems Lighting Needs Power: Wires Distribute Electricity 1 Lighting Needs Power: Electrical Systems Voltage Current Resistance Volts x Amps = Watts Residential: - 120

More information

Multi-Family Common Spaces

Multi-Family Common Spaces Multi-Family Common Spaces Some common spaces in multi-family housing lack windows or skylights and therefore require long hours of use of electric lighting. Welldesigned lighting can help residents or

More information

LED Retrofits for CFLs and HID Retrofit or Replace?

LED Retrofits for CFLs and HID Retrofit or Replace? LED Retrofits for CFLs and HID Retrofit or Replace? Prepared by Eric Strandberg Fall 2015 Commercial CFL to LED applications. Thousands of opportunities. The knowns, the known unknowns, and the unknown

More information

Lighting Existing Conditions and Design Criteria Report

Lighting Existing Conditions and Design Criteria Report Lighting Existing Conditions and Design Criteria Report Executive Summary: This Lighting Existing Conditions and Design Criteria Report will examine and describe the existing lighting systems and all existing

More information

1.3 Auditorium Lighting Redesign

1.3 Auditorium Lighting Redesign 1.3 Auditorium Lighting Redesign 1.3.1 Appearance Description Unlike most of the spaces in Proctor High School, the auditorium is one of the few that did not undergo a previous lighting renovation. Ironically,

More information

Existing Lighting Conditions

Existing Lighting Conditions Casey Schardt Lighting/Electrical Option Howard County General Hospital, Columbia, MD Primary Faculty Consultant: Dr. Mistrick Technical Assignment #1. October 9, 2003 Existing Lighting Conditions The

More information

Lighting Existing Conditions and Design Criteria Report

Lighting Existing Conditions and Design Criteria Report Lighting Existing Conditions and Design Criteria Report Executive Summary: I decided to focus my efforts on the fourth floor of the building which I believe will be the most challenging when considering

More information

5.7 Super/hypermarket

5.7 Super/hypermarket 5.7 Super/hypermarket Techniques General The purpose of a super/hypermarket lighting scheme is to make the store as appealing as possible to customers. It also needs to satisfy more down-to-earth requirements

More information

Lighting Depth Study

Lighting Depth Study Lighting Depth Study Board room The board room is located on the second floor of the Hall Corporate Headquarters with room number 223. The dimensions of the space are approximately 40Ft. x 20.5Ft. giving

More information

DOUGLAS COUNTY ZONING RESOLUTION Section 30 Lighting Standards 3/10/99. -Section Contents-

DOUGLAS COUNTY ZONING RESOLUTION Section 30 Lighting Standards 3/10/99. -Section Contents- SECTION 30 LIGHTING STANDARDS -Section Contents- 3001 Intent... 30-2 3002 Applicability... 30-2 3003 Exceptions... 30-2 3004 Prohibited Lighting... 30-2 3005 General Requirements... 30-3 3006 Sign Lighting...

More information

Ronald Reagan Presidential Library. Reagan Country Café

Ronald Reagan Presidential Library. Reagan Country Café Reagan Country Café Design Concept Although the interior characteristics of this space take on a different theme than the others, it is important to continue a smooth transition from the café to the Multipurpose

More information

LIGHT THE WAY TO THE FUTURE. Your go-to guide to energy-efficient lighting

LIGHT THE WAY TO THE FUTURE. Your go-to guide to energy-efficient lighting LIGHT THE WAY TO THE FUTURE Your go-to guide to energy-efficient lighting BULBS HAVE NEVER BEEN BETTER Saving energy in your home could be as easy as changing a light bulb. Due to the 2007 Energy Independence

More information

1.1 Façade and Building Entrance

1.1 Façade and Building Entrance 1.1 Façade and Building Entrance 1.1.1 Introduction Figure 1.1 Exterior Entrance View The main entrance to the building is located between the two wings of the building. The juxtaposition of the cylindrical

More information

Basic Lighting Terms Glossary (Terms included in the basic lighting course are italicized and underlined)

Basic Lighting Terms Glossary (Terms included in the basic lighting course are italicized and underlined) Basic Lighting Terms Glossary (Terms included in the basic lighting course are italicized and underlined) Accent Lighting Directional lighting to emphasize a particular object or draw attention to a display

More information

Lighting at Borrego Valley Inn (constructed 1997) Photograph Type # Conforming? Comments 25 watt Incandescent (210 lumens) 28 yes Fully-shielded, with decorative pinholes Downward-directed 9 watt compact

More information

LASTS UP TO 2X LONGER THAN OTHER LED BULBS CONSUMES LESS ELECTRICITY VS. CFL BULBS UP TO 50% BRIGHTER VS. CFL BULBS.

LASTS UP TO 2X LONGER THAN OTHER LED BULBS CONSUMES LESS ELECTRICITY VS. CFL BULBS UP TO 50% BRIGHTER VS. CFL BULBS. LASTS UP TO 2X LONGER THAN OTHER LED BULBS CONSUMES LESS ELECTRICITY VS. CFL BULBS UP TO 50% BRIGHTER VS. CFL BULBS Contact Person: FIREFLY ELECTRIC & LIGHTING CORP. 7/F Zen Offices Bldg. 1111 Natividad

More information

Space #2: Science Room 1

Space #2: Science Room 1 Space #2: Science Room 1 size: approx. 32 x26 x 9 853 s.f. description: The Science Room is the smallest space being redesigned, and also the most simple. The room is basically shaped like a large rectangle,

More information

Light sources. Daylight Electric light. Daylight source direct sunlight or diffuse skylight) Indirect light reflected or modified from its primary

Light sources. Daylight Electric light. Daylight source direct sunlight or diffuse skylight) Indirect light reflected or modified from its primary Light sources Daylight Electric light Daylight source direct sunlight or diffuse skylight) Indirect light reflected or modified from its primary Artificial light source incandescent lamps (including tungsten-halogen

More information

For energy savings select ceiling-mounted luminaires that use fluorescent lamps.

For energy savings select ceiling-mounted luminaires that use fluorescent lamps. Cei li ng-mounted Ceiling-mounted luminaires include diffusers and track and adjustable heads that attach directly to the ceiling. They are easy to install compared to recessed luminaires because they

More information

APPENDIX A LUMINAIRE SCHEDULE

APPENDIX A LUMINAIRE SCHEDULE Section Project No. 16563.001 Page 1 of 1 APPENDIX A LUMINAIRE SCHEDULE Project No. 16563.001 Page 1 of 5 Refer to architectural drawings for acceptable alternative options. Type C1 Type L1 Type L2 Type

More information

Executive Summary. Technical Assignment #1 - Existing Conditions Report Relevant computer files: P:\Singley_Tech1_files

Executive Summary. Technical Assignment #1 - Existing Conditions Report Relevant computer files: P:\Singley_Tech1_files Eric Singley Lighting / Electrical Richard G. Mistrick, Ph.D., P.E., FIES Natty Boh Building Baltimore, Maryland Technical Assignment #1 - Existing Conditions Report Relevant computer files: P:\Singley_Tech1_files

More information

Lighting Terminology Wolf Lake Drive, suite 105, Bartlett, TN O F

Lighting Terminology Wolf Lake Drive, suite 105, Bartlett, TN O F Lighting Terminology Accent Lighting Directional lighting to emphasize a particular object or to draw attention to a part of the field of view. Absorption The dissipation of light within a surface or medium.

More information

spacing, efficiency, uniformity, and aesthetic appearance of light patterns for final design for the construction document phase.

spacing, efficiency, uniformity, and aesthetic appearance of light patterns for final design for the construction document phase. spacing, efficiency, uniformity, and aesthetic appearance of light patterns for final design for the construction document phase. Multipurpose Room Overall Design Concept When visiting the Library, Ronald

More information

We re about to change the way you view light.

We re about to change the way you view light. We re about to change the way you view light. LightFair 2015 It s amazing what the right light can do. Amerlux understands the power of light and its mind/body connection. We use this understanding to

More information

Community Design Standards

Community Design Standards In accordance with the Zoning Ordinance Update Adopted December 15, 2015 OUTDOOR LIGHTING Sections: 3.1 Purpose and Intent 3.2 Definitions 3.3 Lighting Plans Required 3.4 Outdoor Lighting Limits 3.5 3.1

More information

Efficient Residential Lighting Clients Love!!!

Efficient Residential Lighting Clients Love!!! Efficient Residential Lighting Clients Love!!! James R Benya, PE, FIES, FIALD BENYA LIGHTING DESIGN West Linn, OR USA Naomi Johnson Miller, FIES, FIALD PACIFIC NORTHWEST NATIONAL LABORATORY Portland, OR

More information

Incandescent. Qualities. Energy and Cost. Use

Incandescent. Qualities. Energy and Cost. Use Incandescent filament base Qualities Energy and Cost Use For more information refer to Incandescent lamps convert electric power into light by passing electricity through a filament of coiled tungsten

More information

7.0 Lighting Breadth:

7.0 Lighting Breadth: 7.0 Lighting Breadth: As mentioned earlier, a large majority of the existing interior lighting system for the Montgomery County Conference Center and Hotel incorporates the use of decorative custom, incandescent

More information

LIT-2. Lighting Philosophy

LIT-2. Lighting Philosophy GENERAL DESIGN GUIDELINES LIT-2. Lighting Philosophy LIT-2. Exterior Lighting Design July 2009 LIGHTING General Lighting Design Guidelines General Lighting Design Guidelines 1.0 Lighting Philosophy Lighting

More information

LED SERIES SPECTACOLOUR FLOOD RGB SPECTACOLOUR FLOOD RGB

LED SERIES SPECTACOLOUR FLOOD RGB SPECTACOLOUR FLOOD RGB LED SERIES SPECTACOLOUR FLOOD RGB Aptly named, the SPECTACOLOUR FLOOD RGB is a high output LED lighting fixture range designed for floodlighting both indoors and outdoors. Thanks to its 120 beam distribution,

More information

How to Select Residential LED Directional Lighting

How to Select Residential LED Directional Lighting How to Select Residential LED Directional Lighting Volume 3, Issue 2 2007 A publication of the Alliance for Solid-State Illumination Systems and Technologies Copyright 2007 by the Alliance for Solid-State

More information

Lumen Method Calculation Assignments Due: Tuesday, November 28, 9:00am

Lumen Method Calculation Assignments Due: Tuesday, November 28, 9:00am Interior Architecture Ohio University College of Fine Arts School of Art+Design ART 2640, Building Systems of Interior Environments Fall Semester 2017 Tuesdays & Thursdays 9:00-10:20 Matthew Ziff, Associate

More information

Westinghouse. Lamps 101

Westinghouse. Lamps 101 Westinghouse Lamps 101 Objectives Explain common lighting terminology to your customers Examine color temperature and explain the Kelvin scale List features and benefits of various lamp types, including:

More information

Josh Lutton. Lighting/Electrical DEF Workforce Development & Technology Building Dubois, PA. 4-1 Exterior. Briefing

Josh Lutton. Lighting/Electrical DEF Workforce Development & Technology Building Dubois, PA. 4-1 Exterior. Briefing 4-1 Exterior Briefing The exterior space that I will be trying to light will be the exterior entrance paths/courtyard. Basically the space is behind the building, away from public view. You access it by

More information

VT & VTTB SERIES. Comfortably illuminates the participants while rendering an excellent video image.

VT & VTTB SERIES. Comfortably illuminates the participants while rendering an excellent video image. VT & VTTB SERIES Fixtures for Drywall and T-Bar th Now wi ns! tio LED op Project Econolite Control Products, Inc. Anaheim, California Specifier Leelite Design Tustin, California Photographer Dell Aquila

More information

ABB i-bus KNX Lighting Constant lighting control

ABB i-bus KNX Lighting Constant lighting control Practical knowledge ABB i-bus KNX Lighting Constant lighting control This manual describes practical knowledge for constant light control. Subject to changes and errors excepted. Limitation of liability:

More information

Computer Lab. Furniture: Floor Plan and Lighting Plan:

Computer Lab. Furniture: Floor Plan and Lighting Plan: Executive Summary This report is an analysis of the existing lighting conditions for the Computer Labs, Pechter Family Music Room, Lecture Hall/Video Conferencing Room, and Main Corridor of the Hawthorn

More information

FLOW FLEX CURVABLE LINEAR LED

FLOW FLEX CURVABLE LINEAR LED EKLIPSE FLOW FLEX V2015 / 6 EN SPECIFICATION FLOW FLEX CHARACTERISTICS The FLOW FLEX is a concealable field curvable LED lighting system made from a higher thermal conductive grade of aluminum. Its versatile

More information

It is important to use the right ballast to ensure the luminaire also ignites at low temperatures.

It is important to use the right ballast to ensure the luminaire also ignites at low temperatures. LINGO n. pl. ling goh. (Informal) The specialized vocabulary of a particular field or discipline. The language and speech, esp. the jargon, slang, or argot, of a particular field, group, or individual:

More information

5-Lighting. Background

5-Lighting. Background 5-Lighting Background General Thomas Edison invented the incandescent lamp in 1879 transforming the way we live and work. However artificial lighting has its risks as well as its benefits. Over the years

More information

PENDANT MOUNT - DIRECT

PENDANT MOUNT - DIRECT Project Type Louver Notes Flush Spotless Lens - down Glo Lens - up Glo Lens up and down PERFORMANCE PER LINEAR FOOT AT 3500K NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY SHIELDING 1000 lm/ft 9.9 W/ft 97

More information

The Three Elements of Light. Richard Kelly

The Three Elements of Light. Richard Kelly The Three Elements of Light General or Ambient lighting provides an area with overall illumination. Also known as ambient lighting, general lighting radiates a comfortable level of brightness, enabling

More information

Lighting. Arctlftecture. Council Note G4. 7. Building Research Council. College of Fine and Applied Arts University of Illinois at Urbana-Champaign

Lighting. Arctlftecture. Council Note G4. 7. Building Research Council. College of Fine and Applied Arts University of Illinois at Urbana-Champaign Council Note G4. 7 Arctlftecture Building Research Council College of Fine and Applied Arts University of Illinois at Urbana-Champaign Good lighting can make your home more attractive and add to the enjoyment

More information

GUIDE FOR OFFICE LIGHTING OPTICS

GUIDE FOR OFFICE LIGHTING OPTICS GUIDE FOR OFFICE LIGHTING OPTICS ver. 1.1 OFFICE LIGHTING IN A NUTSHELL Offices consist of many different types of rooms and areas: work areas, public areas, hallways, meeting rooms, showrooms, kitchens,

More information

Ceramic Metal Halide Lighting

Ceramic Metal Halide Lighting Since 1895 Bulletin 13CMH2 Innovating Design and Performance Ceramic Metal Halide Lighting JW Marriott Grand Rapids, MI. Luminaires by Kirlin. Gary Steffy Lighting Design, Adjustables, Wall Washes Recessed

More information

EXTERIOR LIGHTING DESIGN

EXTERIOR LIGHTING DESIGN October 31, 1995 (Revised: February 21, 2002 June 11, 2009) Technical Bulletin 95-001 Development of Regional Impact Guidance for EXTERIOR LIGHTING DESIGN INTRODUCTION The intent of this Technical Bulletin

More information

Introduction Shank Road Pearland, Texas Fax:

Introduction Shank Road Pearland, Texas Fax: AE-DS1 Introduction Light pollution caused by some outdoor lighting, is a major concern for a growing number of cities, states, environmental organizations, and even the Federal Government. The primary

More information

LUNERA HID LED LAMP LED Replacement for High Intensity Discharge Lamps

LUNERA HID LED LAMP LED Replacement for High Intensity Discharge Lamps LUNERA HID LED LAMP LED Replacement for High Intensity Discharge Lamps [20,000lm / 15,000lm / 9,000lm / 4,500lm] Mogul Base - Vertical Mount - Ballast Driven Description The lamp is a Ballast Driven (plug-and-play)

More information

Technical Assignment #1 Lighting Existing Conditions and Design Criteria Report

Technical Assignment #1 Lighting Existing Conditions and Design Criteria Report Technical Assignment #1 Lighting Existing Conditions and Design Criteria Report William H. Gates Hall Seattle, WA Katherine Jenkins Lighting/Electrical Option October 5, 2006 Faculty Advisor: Dr. Mistrick

More information

A. Title Article XXXXV together with the amendments thereto, shall be known and may be cited as the Town of Riverhead Lighting Ordinance.

A. Title Article XXXXV together with the amendments thereto, shall be known and may be cited as the Town of Riverhead Lighting Ordinance. ARTICLE XXXXV OUTDOOR LIGHTING 108-246 Purpose The general purpose of this Article is to protect and promote the public health, safety and welfare, the quality of life, and the ability to view the night

More information

ROLLER. Lighting fixture ROLLER BG AS 60cм, surface mounted. Lighting fixture Roller BG AS 80см,surface mounted

ROLLER. Lighting fixture ROLLER BG AS 60cм, surface mounted. Lighting fixture Roller BG AS 80см,surface mounted ROLLER Roller is surface mounted luminaire with cylindrical shape. It can be produced with different heights upon request. Due to it`s version with hight protection degree (IP54) it can also be used as

More information

Accentra : A Revolution in the Control of Light

Accentra : A Revolution in the Control of Light Accentra : A Revolution in the Control of Light Adding a new dimension to lighting management, P.A.L. s Accentra illuminates retail and business settings in a way that s both architecturally appealing

More information

WALL HI-OUTPUT. Project. Type. Notes

WALL HI-OUTPUT. Project. Type. Notes Project Type Notes PERFORMANCE/LINEAR FT AT 3000K AND 3500K NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY* 3 9/16 700 lm/ft 7.3 W/ft 96 lm/w 900 lm/ft 9.8 W/ft 92 lm/w 1100 lm/ft 12.5 W/ft 88 lm/w 1 5/8"

More information

CROWNE POINTE RPD16 SUSPENDED, WALL, SURFACE

CROWNE POINTE RPD16 SUSPENDED, WALL, SURFACE CROWNE POINTE RPD16 STANDARD SIZES Ceiling, Suspended Pendant, or Wall Mount Spotlight LAMPING LED - 83+ CRI - 2700K/3000K/3500K/4000K Output: 2100lm (at 111 lm/w) per luminaire Dimming down to 0% FINISH

More information

Redifer Commons Outline

Redifer Commons Outline Large Dining Area Louie s Convenience Store Second Floor Circulation Exterior Front Façade Outline Electrical Depth Structural Breadth Construction Management Breadth Summary Acknowledgements Questions

More information

Traditional lighting technologies

Traditional lighting technologies Traditional lighting technologies Traditional lighting technologies Traditional lighting technologies Incandescent (filament) lamps i n Incandescent lamps n Halogen lamps Traditional lighting technologies

More information

CEILING HI-OUTPUT. Project. Type. Notes

CEILING HI-OUTPUT. Project. Type. Notes Project Type Notes PERFORMANCE/LINEAR FT AT 3000K AND 3500K NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY* 3 9/16 700 lm/ft 7.9 W/ft 89 lm/w 900 lm/ft 10.6 W/ft 85 lm/w 1100 lm/ft 13.5 W/ft 81 lm/w 1 5/8"

More information

Architectural LED Luminaires for the Sophisticated Lighting Designer. Acuity Brands Indy Designer Series Collection Generation 5

Architectural LED Luminaires for the Sophisticated Lighting Designer. Acuity Brands Indy Designer Series Collection Generation 5 Designer Series Collection Generation 5 Architectural LED Luminaires for the Sophisticated Lighting Designer Acuity Brands Indy Designer Series Collection Generation 5 I II Acuity Brands Indy Designer

More information

CES MOUNT SMS MOUNT EAS MOUNT PNS MOUNT LOUVER OPTION 9 (12.1W/FT) LM/W 5104 DIMENSIONS H X W X L: 3" X 2-5/8 X 12", 24" / 36" / 48"

CES MOUNT SMS MOUNT EAS MOUNT PNS MOUNT LOUVER OPTION 9 (12.1W/FT) LM/W 5104 DIMENSIONS H X W X L: 3 X 2-5/8 X 12, 24 / 36 / 48 CES MOUNT SMS MOUNT EAS MOUNT PNS MOUNT LOUVER ITEM LIGHT SOURCE SPECIFICATION 6W/FT, 9W/FT, 12W/FT OPTICS COLORS RGB, RGBW, RGBWWA, RGB+W PERFORMANCE RGB - 48" FIXTURE FIXTURE WATTAGE (TOTAL WATTAGE)

More information

Light In Architecture and Psychology of Light

Light In Architecture and Psychology of Light Designing with Light The majority of the information that we receive about the world around us comes through our eyes. Light is not only an essential prerequisite, it is the medium by which we are able

More information

Light In Architecture and Psychology of Light

Light In Architecture and Psychology of Light Designing with Light Designing with Light The majority of the information that we receive about the world around us comes through our eyes. Light is not only an essential prerequisite, it is the medium

More information

Arch 464 ECS Midterm I Spring Multiple Choice Questions

Arch 464 ECS Midterm I Spring Multiple Choice Questions Arch 464 ECS Midterm I Spring 2009 30 Multiple Choice Questions 1. The large ocular aperture that dominates Botta s San Francisco Museum of Modern Art A. guides daylight to gallery spaces B. provides ambient

More information

EYE Lamps & Luminaires for Retail Applications

EYE Lamps & Luminaires for Retail Applications EYE Lamps & Luminaires for Retail Applications Metal Halide Ceramic Metal Halide Halogen Lamps Urban Act TM Architectural Floodlights Commercial Space Boutiques - Big Box Groceries Restaurants Lounges

More information

Midstream Lighting Product Catalog

Midstream Lighting Product Catalog MIDSTREAM LIGHTING PRODUCTS Product Code Product Description Rebate/Unit Page # 463106 Commercial LED Recessed Downlight 21 Watts 462590 Commercial LED Recessed Downlight 12 Watts 462569 Commercial LED

More information

UNDER CABINET LIGHTING

UNDER CABINET LIGHTING 1 UNDER CABINET LIGHTING BUYING GUIDE How to properly light your countertops and cabinets. We explore the terms, features and products to find the best solution for your home. Published by Yale Appliance

More information

Knife-edge interior cove system for interior architecture

Knife-edge interior cove system for interior architecture Description The Light Cut is a linear cove lighting system comprising a knife-edge extruded profile which integrates perfectly in drywall ceilings and moveable spot modules. To achieve more innovative

More information

LED Replacement for Metal Halide Lamps

LED Replacement for Metal Halide Lamps LUNERA E26 HID LED SUSAN LAMP LAMP GEN2 LED Replacement for High Intensity Discharge Lamps LED Replacement for Metal Halide Lamps 175W/150W/100W/70W/50W, [20,000lm / 15,000lm / 9,000lm E26 / 4,500lm] Mogul

More information

Apsara Interior Solutions

Apsara Interior Solutions +91-8046059751 Apsara Interior Solutions https://www.ohmsenergyais.com/ We are one of the market leaders engaged in importing & supplying of Bulbs and Fixtures. Our product range includes Ohm's LVD Lights.

More information

CHAPTER VII ELECTRIC LIGHTING

CHAPTER VII ELECTRIC LIGHTING CHAPTER VII ELECTRIC LIGHTING 7.1 INTRODUCTION Light is a form of wave energy, with wavelengths to which the human eye is sensitive. The radiant-energy spectrum is shown in Figure 7.1. Light travels through

More information

The decorative side of daylighting Enhanced optical technologies allow designers to use daylight for visual effect

The decorative side of daylighting Enhanced optical technologies allow designers to use daylight for visual effect Volume 4, Issue 6 The decorative side of daylighting Enhanced optical technologies allow designers to use daylight for visual effect By Neall Digert, Solatube Traditionally viewed as an energy saving technique,

More information

PLASTRA SQUARE 9W, indoor wall, 3500K, ETL-dry, LED, square, 9W, white, L/W/H: 11.8"/1.9"/11.8"

PLASTRA SQUARE 9W, indoor wall, 3500K, ETL-dry, LED, square, 9W, white, L/W/H: 11.8/1.9/11.8 PLASTRA SQUARE 9W, indoor wall, 3500K, ETL-dry, LED, square, 9W,, L/W/H: 11.8"/1.9"/11.8" Item number Family Name Description Light Source Length Width Height Voltage Max. Wattage Material Color Installation

More information

HID LED HIGH LUMEN BREAKTHROUGH

HID LED HIGH LUMEN BREAKTHROUGH HID LED HIGH LUMEN BREAKTHROUGH At last, HID Lumens at LED Power With our newest HID LED lamp, you now have a true no-compromise replacement for a 400W lamp. Just what you should expect from a LED lamp.

More information

Correct cap type? e.g. Bayonet Edison Screw GU 10 MR 16. Suitable colour temperature? Warm (3000 K) Cool (4000 K) Bright White (5000+ K)

Correct cap type? e.g. Bayonet Edison Screw GU 10 MR 16. Suitable colour temperature? Warm (3000 K) Cool (4000 K) Bright White (5000+ K) LED BUYER S GUIDE Save energy, time and money with the right LED purchase LED technology has rapidly evolved in the past seven years and is now quickly gaining popularity in the household, representing

More information

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic GENERAL SITE PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS Scope of work narrative Building code review Description of construction Documentation on drawings as List of applicable

More information

HOME SCIENCE CHAPTER 3: LIGHTING IN THE HOME Class: X

HOME SCIENCE CHAPTER 3: LIGHTING IN THE HOME Class: X HOME SCIENCE CHAPTER 3: LIGHTING IN THE HOME Class: X 2017-18 Answer the following questions. 1 What is a foot candle? Ans Light is usually measured in terms of Foot candles. A Foot Candle is the degree

More information

PA-UD-1'x4' LED UP&DOWN PANEL Light. Unique 35% uplight & 65% downlight distribution. Project Location. Catalog # Ordering Information

PA-UD-1'x4' LED UP&DOWN PANEL Light. Unique 35% uplight & 65% downlight distribution. Project Location. Catalog # Ordering Information V.1606 PA-UD-1'x4' LED UP&DOWN PANEL Light Unique 35% uplight & 65% downlight distribution The PA-UD-1x4 series architectural suspended Up/Down dimmable LED panel is a commercial pendant fixture utilizing

More information

CEILING HI-OUTPUT. Project. Type. Notes

CEILING HI-OUTPUT. Project. Type. Notes Project Type Notes PERFORMANCE/LINEAR FT AT 3000K AND 3500K NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY* 3 9/16 700 lm/ft 7.9 W/ft 89 lm/w 900 lm/ft 10.6 W/ft 85 lm/w 1100 lm/ft 13.5 W/ft 81 lm/w 1 5/8"

More information