Fitting Guide for ADSS Cables

Size: px
Start display at page:

Download "Fitting Guide for ADSS Cables"

Transcription

1 28701-NSF Uen Rev.A /10

2 Index 1 General Selection of Fittings Description of Fittings Fittings Fittings Dampers Point versus Point Description of Point Description of a Point Installation Example NSF Uen Rev.A /10

3 1 General This document is a guide to select the correct fittings for Hexatronic ADSS cables. Depending on what type of ADSS cables that is going to be used, the Hexatronic product number of the different fittings is given. As an extra information the area of use for different type of fittings is also described in the document. 2 Selection of Fittings Cable type No of fibres Where to use Type of product Hexatronic No Comments TOL kn (15 mm) up to 48 NSF /01 For installation Thimble NSF /02 load of 10kN. Protection rods NSF /01 NSF /01 For installation load up to max Thimble NSF /02 working load, 14.5kN. NSF /01 damper NSF /01 Optional TOL kn (16.5 mm) up to 72 NSF /01 For installation Thimble NSF /02 load of 10kN. Protection rods NSF /01 NSF /01 For installation load up to max Thimble NSF /04 working load, 15 kn. NSF /04 damper NSF /04 Optional NSF Uen Rev.A /10

4 Cable type No of fibres Where to use Type of product Hexatronic No Comments TOL kn (18.6 mm) up to 96 NSF /02 For installation Thimble NSF /02 load of 10kN. Protection rods NSF /02 NSF /02 For installation load up to max Thimble NSF /04 working load, 16kN. NSF /06 damper NSF /05 TOL kn up to 144 NSF /03 For installation Thimble NSF /04 load of 10kN. (22.7 mm) Protection rods NSF /03 NSF /03 For installation load up to max working load, 18kN. Thimble NSF /05 NSF /08 damper NSF /07 Optional TOL kn up to 48 NSF /01 Thimble NSF /01 (13.8 mm) NSF /02 damper NSF /01 Optional TOL kn (15.5 mm) up to 72 NSF /03 Thimble NSF /01 NSF /01 damper NSF /04 Optional NSF Uen Rev.A /10

5 Cable type No of fibres Where to use Type of product Hexatronic No Comments TOL kn (17.4 mm) up to 96 NSF /05 Thimble NSF /03 NSF /05 damper NSF /05 Optional TOL kn (21.8 mm) up to 144 NSF /06 Thimble NSF /03 NSF /08 damper NSF /0 Optional TOL GRHSLDV 4.0 kn (11.7 mm) up to 48 NSF /02 Thimble NSF /06 NSF /09 damper NSF /02 Optional TOL GRHSLDV 5.0 kn (13.4 mm) up to 72 NSF /01 Thimble NSF /01 NSF /03 damper NSF /03 Optional TOL GRHSLDV 5.5 kn (15.4 mm) up to 96 NSF /03 Thimble NSF /01 NSF /01 damper NSF /04 Optional NSF Uen Rev.A /10

6 Cable type No of fibres Where to use Type of product Hexatronic No Comments TOL GRHSLDV 7.0 kn (20.0 mm) up to 144 NSF /04 Thimble NSF /03 NSF /07 damper NSF /06 Optional All NA Intermediate link between dead end & pole mount. Oval eye NSF Optional, used if hook is to small to accommodate dead end/thimble. 3 Description of Fittings 3.1 Fittings For optical aerial cables of type concentric ADSS, helical dead ends shall be used as tension fittings. For short to medium span lengths the helical dead end is installed directly on the ADSS cable. For long span lengths the ADSS cable is covered with protection rods underneath the dead end. Thimble ADSS cable Picture 1: installed directly on the ADSS. Thimble Protection rods ADSS cable Picture 2: with protection rods NSF Uen Rev.A /10

7 3.2 Fittings For ADSS cables the primary suspension recommendation is to use suspension, see picture 3. This suspension fitting is easy to install, gives excellent vertical load performance and withstands a quite high degree of unbalanced load. Helical rods ADSS cable pulley Picture 3:. 3.3 Dampers In case of vibration problems dampers can be used. The vibration damper is installed with the gripping section towards the tower and the damping section towards the free span, as can be seen in picture 4. Thimble damper ADSS cable Picture 4: damper mounted on ADSS cable NSF Uen Rev.A /10

8 4 Point versus Point 4.1 Description of Point A tension is, as the name implies, a where the cable is tensioned to a pole / tower. On one side of this the cable is tensioned and on the other side it is relaxed. This means that there are longitudinal net forces present in this. ing is normally done at least every 1-1½ kilometer along the line to secure the cable. However, tensioning is also necessary: In first and last pole. At joint closures. When the line describes a larger angle in a pole, normally above 15, see picture 5. At significant altitude changes between poles. When changing cable height in a pole. Pole tension >15 Picture 5: At larger angles tensioning shall be performed. ing is also recommended: When crossing water. When crossing roads, bridges etc. Observe that one tension fitting only supports tension in one direction. Normally two fittings per pole are needed, see picture 6. In the first and last pole of course only one fitting is necessary. Picture 6: Two dead ends per pole are necessary NSF Uen Rev.A /10

9 4.2 Description of Point A suspension is a where the cable is simply just suspended. The cable is suspended in the poles between two tension s. Normally no longitudinal forces act in this. However, differential loads can sometimes occur from ice loads etc. Observe that a suspension fitting cannot work as a tension fitting and shall never be used as such. 4.3 Installation Example To further illustrate when to use tension fittings or suspension fittings please refer to picture 7 below, showing an example of an installed cable line. s s Joint closure s May be tension depending on angle Joint closure s Joint closure Picture 7: Example of when to use tension fittings or suspension fittings NSF Uen Rev.A /10

10 Copyright 2016 Hexatronic Cables & Interconnect Solutions AB. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner. Disclaimer The contents of this document are subject to revision without notice due to continued progress in methodology, design, and manufacturing. Hexatronic shall have no liability for any error or damages of any kind resulting from the use of this document NSF Uen Rev.A /10

CONTENTS AND SERVICES

CONTENTS AND SERVICES CONTENTS 1 LV MAINS AND SERVICES 1.1 Scope 1 1.2 Definitions 2 1.3 Introduction 3 1.4 Design Information 4 1.5 Construction Information 6 Appendix A GA Drawings and Materials Mains 11 Appendix B GA Drawings

More information

Installation Instructions for OPGW Bolted Dead End

Installation Instructions for OPGW Bolted Dead End INS-ACA015 OPGW Bolted Dead End Procedure 1. Disassemble dead end. Remove one bolt from the same side of each keeper. Loosen other bolts to permit conductor to be placed in the conductor groove. If keepers

More information

SPECIFICATION FOR SINGLE-MODE OPTICAL FIBRES

SPECIFICATION FOR SINGLE-MODE OPTICAL FIBRES SINGLE-MODE OPTICAL FIBRES SPECIFICATION FOR SINGLE-MODE OPTICAL FIBRES SPC-00571 JUNE 2006 Revision 3.00 NON-DISCLOSURE OF INFORMATION Information contained in this document is proprietary in nature and/or

More information

AEOLIAN VIBRATION TEST ON 1572 KCMIL BITTERN ACCC/TW CONDUCTOR FOR COMPOSITE TECHNOLOGY CORPORATION

AEOLIAN VIBRATION TEST ON 1572 KCMIL BITTERN ACCC/TW CONDUCTOR FOR COMPOSITE TECHNOLOGY CORPORATION To: Mr. Dave Bryant Composite Technology Corporation 2026 McGaw Avenue Irvine, CA 92614 USA AEOLIAN VIBRATION TEST ON 1572 KCMIL BITTERN ACCC/TW CONDUCTOR FOR COMPOSITE TECHNOLOGY CORPORATION Kinectrics

More information

The EDR Aerial Photo Decade Package

The EDR Aerial Photo Decade Package Wickenburg/Forepaugh W. US Highway 60/N. 436th Ave Wickenburg, AZ 85390 Inquiry Number: April 22, 2011 The Aerial Photo Decade Package Aerial Photo Decade Package Environmental Data Resources, Inc. ()

More information

Materials. Density, Hooke's law, Young modulus. 174 minutes. 174 marks. Page 1 of 29

Materials. Density, Hooke's law, Young modulus. 174 minutes. 174 marks. Page 1 of 29 Materials Density, Hooke's law, Young modulus 174 minutes 174 marks Page 1 of 29 Q1. A uniform wooden beam of mass 35.0 kg and length 5.52 m is supported by two identical vertical steel cables A and B

More information

Huawei WLAN Indoor/Rail Transportation APs Antenna Datasheet

Huawei WLAN Indoor/Rail Transportation APs Antenna Datasheet Huawei WLAN Indoor/Rail Transportation APs Antenna Datasheet Antenna Datasheet 01 Contents 1 Antenna Description...04 2 Selection Policy...04 3 Antennas for Indoor Distributed APs...07 3.1 2.4 GHz Single-Polarized

More information

The EDR Aerial Photo Decade Package

The EDR Aerial Photo Decade Package I-710 Corridor - Segment 5 I-710 Corridor - Segment 5 Los Angeles County, CA 90201 Inquiry Number: March 25, 2009 The EDR Aerial Photo Decade Package EDR Aerial Photo Decade Package Environmental Data

More information

Technical Guarantees No. WP_85

Technical Guarantees No. WP_85 Gaza Electricity Distribution Corporation LTD. Technical Guarantees No. WP_85 Wooden Pole 8.5 m Long Top Diameter 150-180 mm Impregnated No Description Unit Requirements Offered Data 1 Name of Manufacturer

More information

Distribution Tie. Distribution Tie NOMENCLATURE GENERAL RECOMMENDATIONS (440)

Distribution Tie. Distribution Tie NOMENCLATURE GENERAL RECOMMENDATIONS (440) Distribution (Overhead): Section 13 NOMENCLATURE Distribution Tie Tie Tube: Each tie is furnished with Tie Tube Component. The Tie Tube is detached and applied over the conductor. Tape: Shows catalog number,

More information

The EDR Aerial Photo Decade Package

The EDR Aerial Photo Decade Package Former Delco Chassis Plant -Site ID 1104 12950 Eckles Road Livonia, MI 48150 Inquiry Number: August 10, 2009 The EDR Aerial Photo Decade Package EDR Aerial Photo Decade Package Environmental Data Resources,

More information

EXAMPLE 1-4 EXAMPLE 1-5

EXAMPLE 1-4 EXAMPLE 1-5 EXAMPLE 1- Calculate the maximum shear stress τmax in a simply supported wood beam carrying a uniform load of (w=18 kn/m) if the length is 1.75 m and the cross section is rectangular with width 150 mm

More information

Application Guidelines

Application Guidelines Reg No 4-8721 Rev1 Date: 2006-12-27. Sign: KN Application Guidelines Rubber Foot Type 52-02 Height Adjustable Rubber Foot Type 52-10, 52-15 Basic function The basic function of the rubber element is to

More information

2015 Physics. Intermediate 1. Finalised Marking Instructions

2015 Physics. Intermediate 1. Finalised Marking Instructions 205 Physics Intermediate Finalised Marking Instructions Scottish Qualifications Authority 205 The information in this publication may be reproduced to support SQA qualifications only on a noncommercial

More information

Appendix B: Historic Aerial Photographs

Appendix B: Historic Aerial Photographs Yolo County - Solar Ground Tracker Project Phase I Environmental Site Assessment Appendix B: Historic Aerial Photographs Michael Brandman Associates H:\Client (PN-JN)\1759\17590008\Phase I ESA\17590008

More information

Pole Line Hardware. Heavy-Duty Spool Rack (200 A) No. of Wires. Anti-Vibration Kit for Spool Rack. Heavy-Duty Spool Rack (400 A) No.

Pole Line Hardware. Heavy-Duty Spool Rack (200 A) No. of Wires. Anti-Vibration Kit for Spool Rack. Heavy-Duty Spool Rack (400 A) No. Heavy-Duty Spool Rack (200 A) SS401E - SS802E - SS803E - SS804E No. of Wires Overall Length SS401E 1 9-1/2 300 136.3 10 SS802E 2 17-1/2 520 236.3 SS803E 3 25-1/2 780 354.5 5 SS804E 4 33-1/2 1040 472.7

More information

FEATURES ± [0.64 ± 0.05] dia. (no. 22 AWG) tinned nickel leads solderable and weldable

FEATURES ± [0.64 ± 0.05] dia. (no. 22 AWG) tinned nickel leads solderable and weldable SuperTan Wet Tantalum Capacitors s capacitor represents a major breakthrough in wet tantalum technology. Its unique cathode system provides the highest capacitance per unit volume. The design facilitates

More information

Installation of AF-Neutral Section Insulators. 01/07/ Installation of AF Neutral Section

Installation of AF-Neutral Section Insulators. 01/07/ Installation of AF Neutral Section Installation of AF-Neutral Section Insulators page 1 Installation of HS25 Section Insulator Flury-Adjustment JIG with complete tools item no 655.900.001 page 2 Neutral Section 25 kv AC Neutral Section

More information

DESIGN OF MACHINE MEMBERS-I

DESIGN OF MACHINE MEMBERS-I Code No: R31035 R10 Set No: 1 JNT University Kakinada III B.Tech. I Semester Regular/Supplementary Examinations, Dec - 2014/Jan -2015 DESIGN OF MACHINE MEMBERS-I (Mechanical Engineering) Time: 3 Hours

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 4677:2010 AS/NZS 4677:2010 Australian/New Zealand Standard Steel utility services poles AS/NZS 4677:2010 This Joint Australian/New Zealand Standard was prepared by Joint Technical Committee CE-019,

More information

STANDARD MSGDET4AC: NOTES TO DESIGNER

STANDARD MSGDET4AC: NOTES TO DESIGNER GIRDER DETAILS (SHEET 1 OF 2) NOTES TO DESIGNER: Standard is to be used for trapezoidal or curved, 4-span continuous, steel plate girders. The standard includes girder details; tables for plate sizes,

More information

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION SECTION R507 DECKS R507.1 Application. The provisions of this section shall provide prescriptive requirements for the design and construction of all uncovered, wood-framed, single-span exterior decks.

More information

Clamps 2 3/4" Mounting Bolts. Ground Wire Dia. (in) MBA-72 5/ /4" Ground Wire Dia. (in) Pole Clearance

Clamps 2 3/4 Mounting Bolts. Ground Wire Dia. (in) MBA-72 5/ /4 Ground Wire Dia. (in) Pole Clearance Hook for supporting messenger during stringing operation Body tapped for 5/8 diameter bolt Independent clamping - messenger remains clamped if pole shrinkage occurs Teeth on legs to resist movement Aluminum

More information

af-phy July 1996

af-phy July 1996 155.52 Mbps Short Wavelength Physical Layer Specification af-phy-0062.000 Technical Committee 155.52 Mbps Physical Layer Interface Specification for Short Wavelength Laser af-phy-0062.000 July 1996 1 ATM

More information

Popsicle Stick Bridge Design and Construction. Idaho State University

Popsicle Stick Bridge Design and Construction. Idaho State University Popsicle Stick Bridge Design and Construction Bengal STEM Day 2019 Idaho State University 1 Bridge Rules Maximum Allowable Bridge Weight = 12 oz (340 grams). Note that a typical 4½ inch popsicle stick

More information

EIA STANDARD TP-70B TEMPERATURE RISE VERSUS CURRENT TEST PROCEDURE FOR ELECTRICAL CONNECTORS AND SOCKETS EIA/ECA B. June 2007 EIA/ECA B

EIA STANDARD TP-70B TEMPERATURE RISE VERSUS CURRENT TEST PROCEDURE FOR ELECTRICAL CONNECTORS AND SOCKETS EIA/ECA B. June 2007 EIA/ECA B EIA STANDARD ANSI/-2007 Approved: June 8, 2007 TP-70B EIA/ECA-364-70B TEMPERATURE RISE VERSUS CURRENT TEST PROCEDURE FOR ELECTRICAL CONNECTORS AND SOCKETS EIA/ECA-364-70B (Revision of EIA-364-70A) June

More information

300 Series Racks. 19" Wide Opening Stand-Alone Wall Cabinet with Adjustable Rails. Applications. Features. In The Box. Options

300 Series Racks. 19 Wide Opening Stand-Alone Wall Cabinet with Adjustable Rails. Applications. Features. In The Box. Options 300 Series Racks 19" Wide Opening Stand-Alone Wall Cabinet with Adjustable Rails Applications The 300 Series is ideal to house electronic equipment for any type of application, both commercial and residential,

More information

BSR A300 Part 3 Draft 1 Version 1, a

BSR A300 Part 3 Draft 1 Version 1, a Standards & Regulations Cabling and Bracing Standard Proposed Revision This is an excerpt from the draft version of the ANSI standard for supplemental support systems cabling and bracing used in tree care

More information

EZ-WRAP Side Tie NOMENCLATURE GENERAL RECOMMENDATIONS (440) EN-CA

EZ-WRAP Side Tie NOMENCLATURE GENERAL RECOMMENDATIONS (440) EN-CA NOMENCLATURE IDENTIFICATION TAPE TIE TUBE INSULATOR IDENTIFICATION MARK C NECK BLACK F NECK YELLOW J NECK GREEN Conductor Tie Tube: For bare conductor, each tie is furnished with a Tie Tube Component.

More information

1. Enumerate the most commonly used engineering materials and state some important properties and their engineering applications.

1. Enumerate the most commonly used engineering materials and state some important properties and their engineering applications. Code No: R05310305 Set No. 1 III B.Tech I Semester Regular Examinations, November 2008 DESIGN OF MACHINE MEMBERS-I ( Common to Mechanical Engineering and Production Engineering) Time: 3 hours Max Marks:

More information

ACA-4HSRPP-2458 Data Sheet

ACA-4HSRPP-2458 Data Sheet ACA-4HSRPP-2458 2.4/5GHz Antenna ACA-4HSRPP-2458 Data Sheet 4 Antenna with Hinged SMA Reverse Polarity Plug for 2.4/5 GHz ACA-4HSRPP-2458-100R Data Sheet April 12, 2014 2014 ACKme Networks. http://ack.me

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 128-30 First edition 2001-04-01 Technical drawings General principles of presentation Part 30: Basic conventions for views Dessins techniques Principes généraux de représentation

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60826 Third edition 2003-10 Design criteria of overhead transmission lines This English-language version is derived from the original bilingual publication by leaving out all

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 14703 Second edition 2008-04-15 Fine ceramics (advanced ceramics, advanced technical ceramics) Sample preparation for the determination of particle size distribution of ceramic

More information

SECTION VI SCOPE OF WORK

SECTION VI SCOPE OF WORK SECTION VI SCOPE OF WORK Overhead Lines and Underground cables VI 5.2 - i TABLE OF CONTENTS 5.2 SCOPE OF WORKS... 1 5.2.1 General... 1 5.2.2 Factory Acceptance Test... 2 5.2.3 33KV Lines and Cables...

More information

- Characteristic impedance of cabling links is characterised by Return Loss

- Characteristic impedance of cabling links is characterised by Return Loss ISO/IEC 11801 ISO 11801 is the principle design standard for structured cabling systems for all countries of the world that do not have more specific standards, such as ISO 11801 (European Union), TIA

More information

PEDESTAL INSTALLATION. Guidelines for installing adjustable height pedestals

PEDESTAL INSTALLATION. Guidelines for installing adjustable height pedestals BASIC REQUIREMENTS Irrespective of the type of pavers or tiles that will be installed over pedestals, the following basic requirement must be met. Decks must be designed not to exceed the load capacity

More information

Baseball Backstopper System

Baseball Backstopper System D 8 7 6 5 4 3 2 1 Baseball Backstopper System Cable Design - 4 Poles Layout Form Project Name: Zip Code: A2/A1 = D C B1/A2 = B2/A1 = C A2 POLE A1 POLE B A2/B2 = B1/A1 = B B2 POLE B1 POLE A Please fill

More information

International development

International development Oslo 8 th September 2015 Vicky McNiff Head of IP Slide 1 This is Aker Solutions Global provider of products, systems and services to the oil and gas industry Built on more than 170 years of industrial

More information

Hours / 100 Marks Seat No.

Hours / 100 Marks Seat No. 17610 15116 4 Hours / 100 Seat No. Instructions (1) All Questions are Compulsory. (2) Answer each next main Question on a new page. (3) Illustrate your answers with neat sketches wherever necessary. (4)

More information

EVID Surface Mount S Series - X Models

EVID Surface Mount S Series - X Models EVID Surface Mount S Series - X Models EVID-S5.2XB EVID-S5.2XW en Installation manual en 3 Table of contents 1 Safety 4 1.1 Suspension 4 1.2 Notices 4 2 Introduction 5 2.1 System features 5 2.2 Product

More information

Ph.D. Preliminary Qualifying Examination. Cover Page. Thermodynamic. January 17, 2013 (Thursday) 9:30 am 12:30 noon Room 2145 Engineering Building

Ph.D. Preliminary Qualifying Examination. Cover Page. Thermodynamic. January 17, 2013 (Thursday) 9:30 am 12:30 noon Room 2145 Engineering Building GENERAL INSTRUCTIONS: COLLEGE OF ENGINEERING MECHANICAL ENGINEERING Ph.D. Preliminary Qualifying Examination Cover Page Thermodynamic January 17, 2013 (Thursday) 9:30 am 12:30 noon Room 2145 Engineering

More information

Flanged Dowel Box. Load Transfer System INDUSTRIAL SLAB ON GROUND

Flanged Dowel Box. Load Transfer System INDUSTRIAL SLAB ON GROUND Flanged Dowel Box INDUSTRIAL SLAB ON GROUND Designed for construction joints in Post Tension or large shrinkage specifications Large lateral movement and expansion capacity Eliminates the need to drill

More information

Physics Lab 2.2: Tug-of-War

Physics Lab 2.2: Tug-of-War Physics Lab 2.2: Tug-of-War Name Period Purpose: To investigate the tension in a string, the function of a simple pulley, and a simple tug-of-war. Materials: 1 75 cm string 2 30-cm strings 1000 g of assorted

More information

Name two reasons why bridges are built. Name two places where you would find a bridge?

Name two reasons why bridges are built. Name two places where you would find a bridge? Name two reasons why bridges are built. Name two places where you would find a bridge? Before bridges were invented how would an individual travel across a large span of land or huge masses of water Objectives:

More information

Standard Shelving Installation Instructions

Standard Shelving Installation Instructions Standard Shelving Installation Instructions 99-18880-I001_B Copyright 2011 by ALL rights reserved. Information in this document is subject to change without notice. Companies, names and data used in examples

More information

REVISIONS INDEX 2016 ROAD & BRIDGE STANDARDS. September 2017 Revision Letter August 2017 Revision Letter February 2017 Revision Letter

REVISIONS INDEX 2016 ROAD & BRIDGE STANDARDS. September 2017 Revision Letter August 2017 Revision Letter February 2017 Revision Letter REVISIONS INDEX 2016 ROAD & BRIDGE STANDARDS September 2017 Revision Letter August 2017 Revision Letter February 2017 Revision Letter 506.08 ADDED DETAIL FOR TRANSITION FROM GR-MGS1 TO WEAK POST GUARDRAIL.

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 23713 First edition 2005-07-01 Pulps Determination of fibre coarseness by automated optical analysis Polarized light method Pâtes Détermination

More information

DEFENSE LOGISTICS AGENCY DLA Land and Maritime POST OFFICE BOX 3990 COLUMBUS, OH

DEFENSE LOGISTICS AGENCY DLA Land and Maritime POST OFFICE BOX 3990 COLUMBUS, OH DEFENSE LOGISTICS AGENCY DLA Land and Maritime POST OFFICE BOX 3990 COLUMBUS, OH 43218-3990 23 August 2018 MEMORANDUM FOR MILITARY/INDUSTRY DISTRIBUTION SUBJECT: Initial Draft of MIL-PRF-39016/54E. Project

More information

Ohio Department of Transportation Office of Roadway Engineering January 18, 2013

Ohio Department of Transportation Office of Roadway Engineering January 18, 2013 Ohio Department of Transportation Office of Roadway Engineering January 18, 2013 To: Holders of the Traffic Standard Construction Drawings (SCDs) and Plan Insert Sheets (PISs) As of January 18, 2013, eighteen

More information

Manufacturing )2012=100( Producer Price Index (PPI)

Manufacturing )2012=100( Producer Price Index (PPI) Producer Price Index (PPI) Manufacturing )2012=100( First Quarter 2016 Preliminary Release Date: Producer Price IndexJune (PPI) 1 2016 Briefing In the light of the rapid economic and social development

More information

PERFORMANCE SPECIFICATION SHEET SWITCH, ASSEMBLIES, SENSITIVE, TRIGGER, 7 AMPERES, UNSEALED

PERFORMANCE SPECIFICATION SHEET SWITCH, ASSEMBLIES, SENSITIVE, TRIGGER, 7 AMPERES, UNSEALED INCH-POUND MIL-PRF-8805/111B 19 November 2018 SUPERSEDING MIL-PRF-8805/111A 31 October 2001 PERFORMANCE SPECIFICATION SHEET SWITCH, ASSEMBLIES, SENSITIVE, TRIGGER, 7 AMPERES, UNSEALED This specification

More information

101B, 210X, ELM, VSTB Installation Manual

101B, 210X, ELM, VSTB Installation Manual 101B, 210X, ELM, VSTB Installation Manual 99-16105-I001 Copyright 2010 by ALL rights reserved. Information in this document is subject to change without notice. Companies, names and data used in examples

More information

REVISIONS INDEX 2016 ROAD & BRIDGE STANDARDS

REVISIONS INDEX 2016 ROAD & BRIDGE STANDARDS REVISIONS INDEX 2016 ROAD & BRIDGE STANDARDS December 2018 Revision Letter September 2018 Revision Letter September 2017 Revision Letter August 2017 Revision Letter February 2017 Revision Letter Signature

More information

Sheet Metal Design Guidelines

Sheet Metal Design Guidelines Sheet Metal Design Guidelines Hem Design Guidelines Issue XII, June 2015 2 Copyright Notice Geometric Limited. All rights reserved. No part of this document (whether in hardcopy or electronic form) may

More information

Roll No. :... Invigilator s Signature :.. CS/B.TECH(EE)/SEM-5/EE-502/ POWER SYSTEM-I. Time Allotted : 3 Hours Full Marks : 70

Roll No. :... Invigilator s Signature :.. CS/B.TECH(EE)/SEM-5/EE-502/ POWER SYSTEM-I. Time Allotted : 3 Hours Full Marks : 70 Name : Roll No. :.... Invigilator s Signature :.. CS/B.TECH(EE)/SEM-5/EE-502/2011-12 2011 POWER SYSTEM-I Time Allotted : 3 Hours Full Marks : 70 The figures in the margin indicate full marks. Candidates

More information

(1) Brass, an alloy of copper and zinc, consists of 70% by volume of copper and 30% by volume of zinc.

(1) Brass, an alloy of copper and zinc, consists of 70% by volume of copper and 30% by volume of zinc. PhysicsAndMathsTutor.com 1 Q1. (a) Define the density of a material....... (1) Brass, an alloy of copper and zinc, consists of 70% by volume of copper and 30% by volume of zinc. density of copper = 8.9

More information

High Frequency Leaded Resistors

High Frequency Leaded Resistors High Frequency Leaded Resistors FEATURES Speciality product for RF applications Low-inductance non-helical trimmed product Suitable for more than 3 GHz Resistance range: Green product, supports lead-free

More information

Don Hillock Drive ONE UNIT REMAINING. Aurora, ON LARGE INDUSTRIAL FACILITY FOR LEASE IN AURORA FOR LEASE > INDUSTRIAL FACILITY

Don Hillock Drive ONE UNIT REMAINING. Aurora, ON LARGE INDUSTRIAL FACILITY FOR LEASE IN AURORA FOR LEASE > INDUSTRIAL FACILITY FOR LEASE > INDUSTRIAL FACILITY 250 Don Hillock Drive Aurora, ON ONE UNIT REMAINING LARGE INDUSTRIAL FACILITY FOR LEASE IN AURORA Ideally situated right next to the Highway 404/Wellington Street on ramp,

More information

SuperTan Wet Tantalum Capacitors with Hermetic Seal

SuperTan Wet Tantalum Capacitors with Hermetic Seal SuperTan Wet Tantalum Capacitors with Hermetic Seal represents a major breakthrough in wet tantalum capacitor technology. Its unique cathode system provides the highest capacitance per unit volume. The

More information

TECHNICAL TBR 2 BASIS for January 1997 REGULATION

TECHNICAL TBR 2 BASIS for January 1997 REGULATION TECHNICAL TBR 2 BASIS for January 1997 REGULATION Source: ETSI TC-TE Reference: DTBR/TE-005002 ICS: 33.020, 33.040.40 Key words: PDN, testing, type approval, X.25 Attachment requirements for Data Terminal

More information

ISO 7465 INTERNATIONAL STANDARD. Passenger lifts and service lifts Guide rails for lift cars and counterweights T-type

ISO 7465 INTERNATIONAL STANDARD. Passenger lifts and service lifts Guide rails for lift cars and counterweights T-type INTERNATIONAL STANDARD ISO 7465 Fourth edition 27-11-15 Passenger lifts and service lifts Guide rails for lift cars and counterweights T-type Ascenseurs et monte-charges Guides de cabine et de contrepoids

More information

SECTION VI SCOPE OF WORK

SECTION VI SCOPE OF WORK SECTION VI SCOPE OF WORK Overhead Lines and Underground cables VI 5.2 - i TABLE OF CONTENTS 5.2 SCOPE OF WORKS... 1 5.2.1 General... 1 5.2.2 Factory Acceptance Test... 2 5.2.3 33KV Lines and Cables...

More information

Producer Price Index (PPI) Manufacturing )2012=100( Producer Price Index (PPI)

Producer Price Index (PPI) Manufacturing )2012=100( Producer Price Index (PPI) Manufacturing )2012=100( Third Quarter 2017 Preliminary Release Date: December 2017 1 Briefing In the light of the rapid economic and social development in the Emirate of Abu Dhabi, price indices and indicators

More information

ETSI TCR-TR 025 TECHNICAL COMMITTEE July 1995 REFERENCE TECHNICAL REPORT

ETSI TCR-TR 025 TECHNICAL COMMITTEE July 1995 REFERENCE TECHNICAL REPORT ETSI TCR-TR 025 TECHNICAL COMMITTEE July 1995 REFERENCE TECHNICAL REPORT Source: ETSI TC-SES Reference: DTR/SES-02017 ICS: 33.100 Key words: satellite links, telecommunications s Satellite Earth Stations

More information

NZQA unit standard version 2 Page 1 of 5. Demonstrate and apply intermediate knowledge of instrumentation and control system engineering

NZQA unit standard version 2 Page 1 of 5. Demonstrate and apply intermediate knowledge of instrumentation and control system engineering Page 1 of 5 Title Demonstrate and apply intermediate knowledge of instrumentation and control system engineering Level 5 Credits 15 Purpose This unit standard covers intermediate knowledge of the concepts

More information

CONTINUING EDUC ATION

CONTINUING EDUC ATION 3 CONTINUING EDUC ATION FOR WISCONSIN ELECTRICIANS 2017 NEC Article 250 2 Hours WISCONSIN CONTRACTORS INSTITUTE N16 W23217 Stone Ridge Drive Suite 290 Waukesha, WI 53188 262-409-4282 www.wcitraining.com

More information

ISO 9039 INTERNATIONAL STANDARD. Optics and photonics Quality evaluation of optical systems Determination of distortion

ISO 9039 INTERNATIONAL STANDARD. Optics and photonics Quality evaluation of optical systems Determination of distortion INTERNATIONAL STANDARD ISO 9039 Second edition 2008-02-15 Optics and photonics Quality evaluation of optical systems Determination of distortion Optique et photonique Évaluation de la qualité des systèmes

More information

Fully Sealed Container Cermet Potentiometer Professional Grade

Fully Sealed Container Cermet Potentiometer Professional Grade Fully Sealed Container Cermet Potentiometer Professional Grade T Q O QUICK REFERENCE DATA Multiple module Switch module Detent module Special electrical laws No n/a n/a A: linear, L: logarithmic, F: reverse

More information

PARALLEL GROOVE CLAMPS

PARALLEL GROOVE CLAMPS PARALLEL GROOVE CLAMPS 06 6 PARALLEL GROOVE CLAMPS 95 Contents General... 96 Parallel groove clamp with serrated grooves, forged, for aluminium based conductors... 98 Parallel groove clamp for earthwires

More information

MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET

MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET INCH-POUND MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 4PDT, LOW LEVEL TO 5 AMPERES, PERMANENT

More information

Machine Screws, Tapping Screws, and Metallic Drive Screws (Inch Series)

Machine Screws, Tapping Screws, and Metallic Drive Screws (Inch Series) ASME B18.6.3-2013 (Revision of ASME B18.6.3-2010) Machine Screws, Tapping Screws, and Metallic Drive Screws (Inch Series) AN AMERICAN NATIONAL STANDARD ASME B18.6.3-2013 (Revision of ASME B18.6.3-2010)

More information

Producer Price Index (PPI) Manufacturing )2012=100( Producer Price Index (PPI)

Producer Price Index (PPI) Manufacturing )2012=100( Producer Price Index (PPI) Manufacturing )2012=100( First Quarter 2018 Preliminary Release Date: June 2018 1 Briefing In the light of the rapid economic and social development in the Emirate of Abu Dhabi, price indices and indicators

More information

BID ADDENDUM NO. 4 ITB/004/16/KL CITY OF WINTER SPRINGS WTP NO. 1 WATER QUALITY IMPROVEMENTS

BID ADDENDUM NO. 4 ITB/004/16/KL CITY OF WINTER SPRINGS WTP NO. 1 WATER QUALITY IMPROVEMENTS BID ADDENDUM NO. 4 ITB/004/16/KL CITY OF WINTER SPRINGS WTP NO. 1 WATER QUALITY IMPROVEMENTS March 17, 2016 To prospective bidders & others concerned: This addendum sets forth changes and/or information

More information

NSR100 millimeter wave radar User manual

NSR100 millimeter wave radar User manual NSR100 millimeter wave radar User manual Hunan Nanoradar Science and Technology Co., Ltd. Disclaimers Thanks to purchase this product. There is web pages about NSR100 radar sensor in our official website

More information

Fusible Power Metal Film Leaded Resistors

Fusible Power Metal Film Leaded Resistors Fusible Power Metal Film Leaded NFR1, NFR2, NFR3 FEATURES Metal film technology High power (upto 3 W) in small package Small standard sizes (27/414/617) High stability, reliability and uniformity characteristics

More information

PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY SEALED

PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY SEALED INCH-POUND MIL-PRF-6106/19G 18 November 2011 SUPERSEDING MIL-PRF-6106/19F 10 November 2000 PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY

More information

Wrought Copper and Wrought Copper Alloy Solder-Joint Drainage Fittings DWV

Wrought Copper and Wrought Copper Alloy Solder-Joint Drainage Fittings DWV ASME B16.29-2017 (Revision of ASME B16.29-2012) Wrought Copper and Wrought Copper Alloy Solder-Joint Drainage Fittings DWV AN AMERICAN NATIONAL STANDARD ASME B16.29-2017 (Revision of ASME B16.29-2012)

More information

SAW Components. Low-Loss Filter. RF360 Europe GmbH. A Qualcomm TDK Joint Venture. Data Sheet B5013. Ordering code: Date: Nov 30, 2004 Version:

SAW Components. Low-Loss Filter. RF360 Europe GmbH. A Qualcomm TDK Joint Venture. Data Sheet B5013. Ordering code: Date: Nov 30, 2004 Version: RF360 Europe GmbH A Qualcomm TDK Joint Venture SAW Components Series/type: Ordering code: Date: Nov 30, 2004 Version: RF360 products mentioned within this document are offered by RF360 Europe GmbH and

More information

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET INCH-POUND MIL-PRF-83536/32D 03 October 2017 SUPERSEDING MIL-PRF-83536/32C 21 April 2015 PERFORMANCE SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 3PDT, 25 AMPERES (RESISTIVE),

More information

NPS/001/005 Technical Specification for Overhead Line Steelwork, Conductor Fittings, Insulator Fittings and Stay Fittings.

NPS/001/005 Technical Specification for Overhead Line Steelwork, Conductor Fittings, Insulator Fittings and Stay Fittings. Version:- 6.0 Date of Issue:- January 2014 Page 1 of 21 NPS/001/005 Technical Specification for Overhead Line Steelwork, Conductor Fittings, Insulator Fittings and Stay Fittings. 1. Purpose The purpose

More information

Compliance with this acceptable construction practice satisfies Performance Requirement P2.5.2 for balustrades or other barriers.

Compliance with this acceptable construction practice satisfies Performance Requirement P2.5.2 for balustrades or other barriers. Page 1 of 5 PART 3.9 SAFE MOVEMENT AND ACCESS 2010 Edition PART 3.9.2 BALUSTRADES Acceptable construction practice 3.9.2.1 Application Compliance with this acceptable construction practice satisfies Performance

More information

Network Standard NS

Network Standard NS Network Standard NS 21-2006 Artwork on Western Power Assets Technical Requirements for application to South West Interconnected System (SWIS) DMS #1049174 NS 21-2006 Artwork on Western Power Assets REVISION

More information

ND1127:2000/09 TECHNICAL RECOMMENDATION. Part B. Issue 1. (Part B) DWDM Interconnect Between UK Licensed Operators

ND1127:2000/09 TECHNICAL RECOMMENDATION. Part B. Issue 1. (Part B) DWDM Interconnect Between UK Licensed Operators () DWDM Interconnect Between UK Licensed Operators TECHNICAL RECOMMENDATION Issue 1 Network Interoperability Consultative Committee Ofcom Riverside House, 2a Southwark Bridge Road, London SE1 9HA UK http://www.nicc.org.uk

More information

ISO ~ISOJ INTERNATIONAL STANDARD. Plastics and ebonite - Determination of indentation hardness by means of a durometer (Shore hardness) - --

ISO ~ISOJ INTERNATIONAL STANDARD. Plastics and ebonite - Determination of indentation hardness by means of a durometer (Shore hardness) - -- INTERNATIONAL STANDARD ISO 868 Third edition 2003-03-01 Plastics and ebonite - Determination of indentation hardness by means of a durometer (Shore hardness) Plastiques et ebonite -- Determination de la

More information

Lead (Pb)-Free Precision Leaded Resistors

Lead (Pb)-Free Precision Leaded Resistors DESCRIPTION, and precision leaded thin film resistors combine the proven reliability of the professional products with an advanced level of precision and. Therefore they are perfectly suited for applications

More information

NSP/004/107 (OHI 7) Guidance on the selection of conductor jumpers and non-tension connections

NSP/004/107 (OHI 7) Guidance on the selection of conductor jumpers and non-tension connections Version:- 3.0 Date of Issue:- September 2015 Page 1 of 12 NSP/004/107 (OHI 7) Guidance on the selection of conductor jumpers and non-tension connections 1. Purpose The purpose of this document is to provide

More information

POWER TOOL DESIGN FOR GOOD ERGONOMICS

POWER TOOL DESIGN FOR GOOD ERGONOMICS POWER TOOL DESIGN FOR GOOD ERGONOMICS Skogsberg L 1 1. Manager Product Ergonomics Atlas Copco Tools AB SE 10523 Stockholm E-mail: lars.skogsberg@se.atlascopco.com To design a powertool for good ergonomics

More information

INTERNATIONAL TELECOMMUNICATION UNION TRANSMISSION MEDIA CHARACTERISTICS CHARACTERISTICS OF A DISPERSION-SHIFTED SINGLE-MODE OPTICAL FIBRE CABLE

INTERNATIONAL TELECOMMUNICATION UNION TRANSMISSION MEDIA CHARACTERISTICS CHARACTERISTICS OF A DISPERSION-SHIFTED SINGLE-MODE OPTICAL FIBRE CABLE INTERNATIONAL TELECOMMUNICATION UNION ITU-T G.653 TELECOMMUNICATION (03/93) STANDARDIZATION SECTOR OF ITU TRANSMISSION MEDIA CHARACTERISTICS CHARACTERISTICS OF A DISPERSION-SHIFTED SINGLE-MODE OPTICAL

More information

EIA STANDARD TP-27B. Mechanical Shock (Specified Pulse) Test Procedure for Electrical Connectors EIA B ELECTRONIC INDUSTRIES ASSOCIATION

EIA STANDARD TP-27B. Mechanical Shock (Specified Pulse) Test Procedure for Electrical Connectors EIA B ELECTRONIC INDUSTRIES ASSOCIATION ANSI/-1996 Approved: April 17, 1996 EIA STANDARD TP-27B Mechanical Shock (Specified Pulse) Test Procedure for Electrical Connectors (Revision of EIA-364-27A) MAY 1996 ELECTRONIC INDUSTRIES ASSOCIATION

More information

PATHWAY 3G MODULAR ACCESS SYSTEM

PATHWAY 3G MODULAR ACCESS SYSTEM PATHWAY 3G MODULAR ACCESS SYSTEM TECHNICAL & ARCHITECTURAL SPECIFICATIONS Manufactured in the USA Homecare Products, Inc. All rights reserved. All text and images contained in this document are proprietary

More information

ISO INTERNATIONAL STANDARD. Technical product documentation Lettering Part 3: Greek alphabet

ISO INTERNATIONAL STANDARD. Technical product documentation Lettering Part 3: Greek alphabet INTERNATIONAL STANDARD ISO 3098-3 Second edition 2000-05-01 Technical product documentation Lettering Part 3: Greek alphabet Documentation technique de produits Écriture Partie 3: Alphabet grec Reference

More information

User Guide. Keysight N6850A Broadband Omnidirectional Antenna

User Guide. Keysight N6850A Broadband Omnidirectional Antenna User Guide Keysight N6850A Broadband Omnidirectional Antenna Notices Keysight Technologies, Inc. 2012-2015 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

OVERHEAD DESIGN MANUAL

OVERHEAD DESIGN MANUAL OVERHED DESIGN MNUL Section 5 Clearances pproved by: F. ZINI ENERGEX 2018 MNUL 00302 GUIDELINES For communication clearances purposes the following distinctions are made: Telstra telephony only

More information

Total precast solution for large stadium projects meet tight schedule

Total precast solution for large stadium projects meet tight schedule Tailor Made Concrete Structures Walraven & Stoelhorst (eds) 2008 Taylor & Francis Group, London, ISBN 978-0-415-47535-8 Total precast solution for large stadium projects meet tight schedule T.J. D Arcy

More information

RITE-HITE RAINGUARD TM

RITE-HITE RAINGUARD TM RITE-HITE RAINGUARD TM RG-3000 Trailer Top Seal Installation Instructions & Owner s Manual Date of Installation: This Manual Covers All Units Shipped 8/04 to Date PRINTED IN U.S.A. PUBLICATION NO. RG30-0010

More information

FIBERLIGN (FDC8) Drop Cable Storage Bracket

FIBERLIGN (FDC8) Drop Cable Storage Bracket MARCH 2017 FIBERLIGN (FDC8) Drop Cable Storage Bracket Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED TM product before application.

More information

AN1756 Application note

AN1756 Application note Application note Choosing a DALI implementation strategy with ST7DALIF2 Introduction This application note describes how to choose a DALI (Digital Addressable Lighting Interface) implementation strategy

More information

VEUE PIVOT ARM INSTALLATION MANUAL. February 2017

VEUE PIVOT ARM INSTALLATION MANUAL. February 2017 VEUE PIVOT ARM INSTALLATION MANUAL February 2017 CONTENTS February 2017 This manual is to be read in conjunction with the Product Specifications & Assembly manual SECTION NO. DESCRIPTION PAGE NO. SECTION

More information

Installation Guide of Load Cell

Installation Guide of Load Cell Installation Guide of Load Cell Notices Copyright 2000-2014 by Unico, Incorporated. All rights reserved. No part of this publication may be copied, reproduced, or reduced to any electronic media or machine-readable

More information