1 to Measure is to Know but how to measure? Gert Rietveld Nederlands Meetinstituut Delft VKRT meeting 8 Feb
2 Nederlands Meetinstituut Legal inspection Testing and certification Scientific metrology (national standards) VKRT meeting 8 Feb
3 Overview Measurement in daily life and in your profession How to make a good measurement? What is a measurement? Uncertainty Effects affecting measurements Units & the role of NMi Pass/fail testing ISO requirements Summary VKRT meeting 8 Feb
4 You wake up VKRT meeting 8 Feb
5 Make a cup of tea VKRT meeting 8 Feb
6 On the road VKRT meeting 8 Feb
7 Fill up with petrol VKRT meeting 8 Feb
8 Complement breakfast VKRT meeting 8 Feb
9 Oops! VKRT meeting 8 Feb
10 Do your shopping VKRT meeting 8 Feb
11 Make a small bet VKRT meeting 8 Feb
12 Take a taxi home VKRT meeting 8 Feb
13 Measuring in your job Production and testing of materials: Weight Temperature Force Time Hardness Length Volume Strength Particle size VKRT meeting 8 Feb
14 Measurement What do you want to know? How are you doing the measurement? How good is the measurement? The art of measurement De Geograaf Jan Vermeer VKRT meeting 8 Feb
15 Metrology and standaards Metrology: the science of measurement Why measurement standards and calibrations? We do know the length of a meter You can not thrust measurement equipment without verification! VKRT meeting 8 Feb
16 to Measure is to Know What is a measurement? Comparison to a reference Result: ±? Value = number x unit VKRT meeting 8 Feb
17 Uncertainty Uncertainty the qualification of the result of the measurement In which band can I expect the true value, related to the indication of the instrument Simply said: Uncertainty is lack of information VKRT meeting 8 Feb
18 Uncertainty Precise Accurate VKRT meeting 8 Feb
19 Uncertainty sources Noise, repeatability (imprecision) Systematic effects: Environment (air, oil, water, etc) Temperature of test setup and of environment Sample dimensions Time, drifts Resolution Offsets, biases Human factor (operator) Errors in analysis (Arrhenius plot) Sample preparation Reference equipment (calibration!) Etc. the less you know, the better you measure VKRT meeting 8 Feb
20 Sample preparation Batch reproduction how stable is production? Sampling within batch how homogeneous is production? VKRT meeting 8 Feb
21 to measure is to know What is a measurement? Comparison with a reference Result: Value = number x unit Task of NMi - SI units! VKRT meeting 8 Feb
22 History of the meter 4000 BC Egypt Cubit Forearm Pharaoh 1130 England Yard Nose to thumb King 1790 France Meter Circumference earth 1799 France Meter Pt rod 1960 CGPM Meter Wavelength Kr line 1983 CGPM Meter Speed of light VKRT meeting 8 Feb
23 The ultimate kg Grand K BIPM: scientific centre for metrology, depository of the Grand K mass reference VKRT meeting 8 Feb
24 Compare measurements NL DE? Industry requires traceability! Unbroken chain of measurements to (inter)national measurement standards VKRT meeting 8 Feb
25 Compare measurements (2) NL UK DE Via traceability Comparable measurements! VKRT meeting 8 Feb
26 1 kg Key comparison VKRT meeting 8 Feb
27 Pass / fail margins Nominal value PASS UNDEFINED FAIL : measurement value with 95% uncertainty interval (k=2) VKRT meeting 8 Feb
28 Doping - guilty or not? Player ng/ml Player ng/ml 2 ng/ml zero VKRT meeting 8 Feb
29 ISO requirements test & cal labs ISO requirements for test and calibration laboratories: Management system equivalent to ISO 9001 Technical competence Personnel Test procedures Measurement uncertainty Test equipment Cross-checks Quality control interlaboratory tests VKRT meeting 8 Feb
30 ISO standards for testing Sample characteristics Preparation of samples Describe test method Critical attention points Uncertainty contributions Minimum number of contributions: repeatability, reproducibility + systematic effects Methods for determining uncertainty Typical uncertainty budget VKRT meeting 8 Feb
31 To Measure is to Know A measurement value without uncertainty is meaningless Precise accurate Behing each measurement there is a standard (preferably a quantum standard) Only traceable measurement values can be compared with each other Knowing = measuring = our profession! VKRT meeting 8 Feb
32 Nederlands Meetinstituut The art of measurement De Geograaf Jan Vermeer VKRT meeting 8 Feb
Metrology at the service of the economy, society and citizens
Bureau International des Poids et Mesures Metrology at the service of the economy, society and citizens Dr Martin Milton Director, BIPM 26 th Sept 2013 Bureau International des Poids et Mesures Established
More informationSMD ENS Metrology - National Standards. Short overview. Hugo Pirée. World Metrology Day 2018 Brussels.
SMD ENS Metrology - National Standards Short overview Hugo Pirée World Metrology Day 2018 Brussels Federal government FPS ECONOMY Gen. Direction QUALITY & SAFETY Division METROLOGY 14 persons National
More informationThe Importance of Global Metrology for Standards, Industry and Trade: Metrology in a Dynamic World
The Importance of Global Metrology for Standards, Industry and Trade: Metrology in a Dynamic World v1 Dr Martin J.T. Milton Director of the BIPM Riyadh and Jeddah 18 and 19 May 2016 The importance of global
More informationTraceability measurement results of accurate time and frequency in Bosnia and Herzegovina
INFOTEH-JAHORINA Vol. 11, March 2012. Traceability measurement results of accurate time and frequency in Bosnia and Herzegovina Osman Šibonjić, Vladimir Milojević, Fatima Spahić Institute of Metrology
More informationInternationally accepted framework for metrology
Internationally accepted framework for metrology Andy Henson BIPM Working Groups The BIPM Bureau International des Poids et Measures the intergovernmental organization through which Member States act together
More informationJoint ILAC CIPM Communication regarding the. Accreditation of Calibration and Measurement Services. of National Metrology Institutes.
Joint ILAC CIPM Communication regarding the Accreditation of Calibration and Measurement Services of National Metrology Institutes 7 March 2012 Authorship This document was prepared by the International
More informationPeter Dack, Vice President Sales & Marketing Radian Research, Inc.
Peter Dack, Vice President Sales & Marketing pdack@radianresearch.com Radian Research, Inc. Radian Research, Inc. is a world leader in State of the Art energy measurement instrumentation. Radian designs,
More informationKeysight Technologies Optical Power Meter Head Special Calibrations. Brochure
Keysight Technologies Optical Power Meter Head Special Calibrations Brochure Introduction The test and measurement equipment you select and maintain in your production and qualification setups is one of
More informationDesignated Institutes participating in the CIPM MRA
Designated Institutes participating in the CIPM MRA Expectations and nomination form Version 1.2 Contents 1. Introduction... 1 2. Designated Institute in Appendix A of the KCDB... 2 2.1. Designation of
More informationBureau International des Poids et Mesures. International Recognition of NMI Calibration and Measurement Capabilities: The CIPM MRA
Bureau International des Poids et Mesures International Recognition of NMI Calibration and Measurement Capabilities: The CIPM MRA Prof. Michael Kühne International School of Physics Enrico Fermi Metrology
More informationSpecific Accreditation Criteria Calibration ISO/IEC Annex. Electrical metrology
Specific Accreditation Criteria Calibration ISO/IEC 17025 Annex Electrical metrology January 2018 Copyright National Association of Testing Authorities, Australia 2014 This publication is protected by
More information5 m-measurement system for traceable measurements of tapes and rules
5 m-measurement system for traceable measurements of tapes and rules Tanfer Yandayan*, Bulent Ozgur Tubitak Ulusal Metroloji Enstitusu (UME) PK54, 4147 Gebze-KOCAELI / TURKEY ABSTRACT Line standards such
More informationSEM Magnification Calibration & Verification: Building Confidence in Your Scale Bar
SEM Magnification Calibration & Verification: Building Confidence in Your Scale Bar Mark A. Koten, Ph.D. Senior Research Scientist Electron Optics Group McCrone Associates Why check your SEM image calibration?
More informationNew Certified Reference Materials for Chromatography
New Certified Reference Materials for Chromatography Dr. Frank Michel Frank.michel@sial.com sigma-aldrich.com/analytical 2012 Sigma-Aldrich Co. All rights reserved. Use of Certified Reference Materials
More information19th Meeting of the Directors of NMIs and Member State Representatives with BIPM
19th Meeting of the Directors of NMIs and Member State Representatives with BIPM Session on Advanced Manufacturing, Digitization and Internet of Things Thursday, 19 th October 2017 11:10 to 13:00 Advanced
More informationInvestigation of Two Different Techniques for Accurate Measurements of Sinusoidal Signals
Investigation of Two Different Techniques for Accurate Measurements of Sinusoidal Signals Shereen M. El-Metwally 1, Mamdouh Halawa 2 1 Department of Systems and Biomedical Engineering, Cairo University,
More informationCRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TIME AND FREQUENCY METROLOGY
CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TIME AND FREQUENCY METROLOGY Approved By: Chief Executive Officer: Ron Josias Senior Manager: Mpho Phaloane Revised By: Specialist Technical Committee
More informationCIPM and CCPR What are these organizations and how do they affect my testing results. Maria Nadal Photometry, Surface Color and Appearance NIST
CIPM and CCPR What are these organizations and how do they affect my testing results Maria Nadal Photometry, Surface Color and Appearance NIST CIE USA Annual Meeting October 6-7, 2014 Calibration Laboratory
More informationPower Quality Measurements the Importance of Traceable Calibration
Power Quality Measurements the Importance of Traceable Calibration H.E. van den Brom and D. Hoogenboom VSL Dutch Metrology Institute, Delft, the Netherlands, hvdbrom@vsl.nl Summary: Standardization has
More informationTRANSMITTER MODEL: KAS-2030M
Page 1 of 16 FCC PART 15, SUBPART B and C TEST REPORT for TRANSMITTER MODEL: KAS-2030M Prepared for WILDLIFE TECHNOLOGIES 115 WOLCOTT STREET MANCHESTER, NEW HAMPSHIRE 03103 Prepared by: KYLE FUJIMOTO Approved
More informationCTAG:b01ac469edcbee4d9e5f84a83a1962a5 Certificate of Calibration
CTAG:bac69edcbeed9e5f8a8a96a5 Certificate of Calibration Data Type: FOUND-LEFT Certificate No: 859 Instrument Description Manufacturer Model Serial Number Inventory Number CABLE ANALYZER FLUKE NETWORKS
More informationTIME AND FREQUENCY ACTIVITIES AT THE CSIR NATIONAL METROLOGY LABORATORY
TIME AND FREQUENCY ACTIVITIES AT THE CSIR NATIONAL METROLOGY LABORATORY E. L. Marais and B. Theron CSIR National Metrology Laboratory PO Box 395, Pretoria, 0001, South Africa Tel: +27 12 841 3013; Fax:
More informationUsing Reference Multimeters for Precision Measurements
Using Reference Multimeters for Precision Measurements Advanced techniques for improved confidence in metrology Teleconference: US & Canada Toll Free Dial-In Number: 1-(866) 230-5936 International Dial-In
More informationEstablishing Traceability to UTC
White Paper W H I T E P A P E R Establishing Traceability to UTC "Smarter Timing Solutions" This paper will show that the NTP and PTP timestamps from EndRun Technologies Network Time Servers are traceable
More informationCertificate of Calibration
Certificate of Calibration ISO/IEC 17025:2005 and ANSI/NCSL Z540.1-1994 Model Number Manufacturer Description Serial Number Customer Asset No. 11667A Keysight Technologies Inc DC-18 GHz power splitter,
More informationAmerican Association for Laboratory Accreditation
Page 1 of 6 5700A/5720A/3458A Purpose of Study This Measurement Advisory Committee (MAC) working group was formed to focus on the performance enhancement offered by artifact calibration for the Fluke 5700A,
More informationSupplementary Information
Supplementary Information Standards Laboratory Calibration Order 1-999999999-1 Model 8481A Manufacturer Agilent Technologies Description Power Sensor, 10 MHz to 18 GHz, -30 to +20 dbm Serial 2 Options
More informationSTATUS REPORT OF TIME AND FREQUENCY LAB. (VIETNAM METROLOGY INSTITUTE)
STATUS REPORT OF TIME AND FREQUENCY LAB. (VIETNAM METROLOGY INSTITUTE) Trieu Viet Phuong Head of Time and Frequency Laboratory, VMI Email: phuongtv@vmi.gov.vn DA NANG 11-2016 About TFL Laboratory of time
More informationCertificate of Calibration
Certificate of Calibration ISO/IEC 17025:2005 Certificate Number 1-5607144213-1 Model Number Manufacturer Description Serial Number 34401A Keysight Technologies Inc Digital multimeter, 6.5 digit MY41007563
More informationTIME & FREQUENCY SERVICES IN MALAYSIA
TIME & FREQUENCY SERVICES IN MALAYSIA Presented by : Mohd Rafiq Bin Abdul Kamal Metrologist National Metrology Laboratory SIRIM Berhad, Malaysia Time & Frequency Laboratory National Metrology Laboratory
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI National Accreditation Board 11617 Coldwater Road, Fort Wayne, IN 46845 USA This is to certify that Kanawha Scales and Systems, Inc. 26 Whitney Drive Milford, OH 45150
More information1433 SERIES. High-Accuracy Decade Resistor User and Service Manual
1433 SERIES High-Accuracy Decade Resistor User and Service Manual Contents Chapter 1 Introduction...1 1.1 Product Overview... 1 Chapter 2 Specifications...2 Decade Specifications... 2 Chapter 3 Operation...5
More informationMachine Tool & Gear 1021 N. Shiawassee St. Corunna, MI Temperature Uniformity Survey Report
Machine Tool & Gear 1021 N. Shiawassee St. Corunna, MI 48817 Temperature Uniformity Survey Report Report Time: 11:24 AM Report Date: 5/18/2018 Furnace: DRA012 Furnace Information Survey Result: Furnace
More informationHow accurate is a measurement? Why should you care? Dr. Andrew Roscoe
How accurate is a measurement? Why should you care? Dr. Andrew Roscoe Does V=IR? You are asked to confirm the hypothesis that V=IR. The following equipment is used: I, RMS Current (Amps) V, RMS Voltage
More informationCERTIFICATE OF CALIBRATION
CERTIFICATE OF CALIBRATION Issued by: Pico Technology Ltd. Certificate Number: 9999 of: James House, Colmworth Business Park, St. Neots, Cambridgeshire, Signature: PE19 8YP UNITED KINGDOM Tel: +44 (0)
More informationModel AccuBridge 6242D Resistance Bridge
Automated Thermometry Bridge with Ratio 100:1 Resistance and temperature applications Range 0.001 Ω to 100 MΩ with optional 1 GΩ Accuracy < 0.1 ppm with optional 0.05 ppm Ratio self-calibration System
More informationCER-ASEAN Integration Partnership Forum. CER-ASEAN participation in global frameworks for international recognition and harmonisation of measurement
CER-ASEAN Integration Partnership Forum CER-ASEAN participation in global frameworks for international recognition and harmonisation of measurement Dr Angela Samuel Director, International Relations Mr
More informationThe Metrology Behind Wideband/RF Improvements to the Fluke Calibration 5790B AC Measurement Standard
1. Abstract The Metrology Behind Wideband/RF Improvements to the Fluke Calibration 5790B AC Measurement Standard Authors: Milen Todorakev, Jeff Gust Fluke Calibration. 6920 Seaway Blvd, Everett WA Tel:
More informationLength section: New calibration and research services
Length section: New calibration and research services O Kruger October 2015 T026 Overview Traditional traceability chart Traceability chart with length R&D projects Overview of Various R&D projects Conclusion
More informationReproducibility of surface roughness in reaming
Reproducibility of surface roughness in reaming P. Müller, L. De Chiffre Technical University of Denmark, Department of Mechanical Engineering, Kgs. Lyngby, Denmark pavm@mek.dtu.dk ABSTRACT An investigation
More informationREPORT OF TIME AND FREQUENCY LABORATORY (VIETNAM METROLOGY INSTITUTE)
Trieu Viet Phuong Deputy head of Time and Frequency Laboratory (TFL) Vietnam Metrology Institute (VMI) N 0 8, Hoang Quoc Viet Road, Caugiay District, Hanoi, Vietnam About Time & Frequency Laboratory (TFL)
More informationOP710. Multichannel Optical Power Meter Instruction Manual. (Also supports the OP710-ANX)
Multichannel Optical Power Meter Instruction Manual (Also supports the OP710-ANX) www.optotest.com 1.805.987.1700 Contacting OptoTest Corporation 1.805.987.1700 (7:30 a.m. to 5 p.m. PST) www.optotest.com
More informationReview of uncertainty sources in indoor PV calibration of c-si, and thin film single junction and multi junction cells and modules
Loughborough University Institutional Repository Review of uncertainty sources in indoor PV calibration of c-si, and thin film single junction and multi junction cells and modules This item was submitted
More informationBorderline between CIPM MRA and testing activities
Borderline between CIPM MRA and testing activities Michela Sega, EURAMET TC-MC Chair INRIM-Italy 7 th Meeting of the Focus Group on Facilitating National Metrology Infrastructure Development Zagreb, Croatia,
More informationSynchrometrology and PMU Testing at NIST
Synchrometrology and PMU Testing at NIST Jerry FitzPatrick and Tom Nelson National Institute of Standards and Technology i-pcgrid Workshop 2013 March 27, 2013 2 Topics for Today NIST Mission SGIP NIST
More informationILAC input to CIPM MRA Review Workshop October 2015
ILAC input to CIPM MRA Review Workshop 13-14 October 2015 BIPM Sevres 13 October 2015 By Erik Oehlenschlaeger ILAC (DANAK) ILAC History ILAC first started as a conference in 1977 (Copenhagen) with the
More informationC E R T I F I C A T E OF C A L I B R A T I O N
NCL CALIBRATION LABORATORIES Calibration File No.: 1233 Client.: APREL C E R T I F I C A T E OF C A L I B R A T I O N It is certified that the equipment identified below has been calibrated in the NCL
More informationCalibration Certificate
ÌÇa8SÈ-EÇÂ!ÈfeFÎ Calibration Certificate Date of issue 2015-12-08 Calibrated by Gert Schnipper Approved by Ole F. Carlsen 1 (5) CUSTOMER: GN RESOUND A/S GTO LAUTRUPBJERG 7-9 2750 BALLERUP DEVICE UNDER
More informationCertified Reference Materials for UV, Visible, NIR and IR Molecular Spectroscopy
Certified Reference Materials for UV, Visible, NIR and IR Molecular Spectroscopy RM-1N3N5DHG Set Serial No: 23135 Customer Details: Starna Cells Inc 5950 Traffic Way Atascadero CA 93422 U.S.A. The customer
More informationOUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT
Page 1 of 16 FCC PART 15, SUBPART B and C TEST REPORT for OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT Prepared for MINASKA OUTDOORS 6517 PLATTE AVENUE LINCOLN, NEBRASKA 68507 Prepared by: KYLE FUJIMOTO
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationDTI-1000 & STS-100/102. Digital Temperature Indicator & STS Reference Sensor
DTI-1000 & STS-100/102 Digital Temperature Indicator & STS Reference Sensor What to expect Wide Temperature Range Reliable Temperature Readings The superior specifications combined with a long history
More informationSupplementary Comparison EUROMET.EM.RF-S25 EURAMET Project 819. Comparison of Electrical Field Strength Measurements above 1 GHz.
EURAMET.EM.RF-S25 Final Report page 1 of 120 Supplementary Comparison EUROMET.EM.RF-S25 EURAMET Project 819 Comparison of Electrical Field Strength Measurements above 1 GHz Final Report Karel Dražil Czech
More informationThe cost and benefits of the CIPM MRA to the NMIs of the world: the Brazilian experience
The cost and benefits of the CIPM MRA to the NMIs of the world: the Brazilian experience João Alziro Herz da Jornada President of Inmetro- Brazil Costs and Benefits of the CIPM MRA, as perceived by Inmetro-
More informationPROMOTING QUALITY AND STANDARDS
PROMOTING QUALITY AND STANDARDS 1 PROMOTING QUALITY AND STANDARDS Strengthen capacities of national and regional quality systems (i.e. metrology, standardization and accreditation) Build conformity assessment
More informationTime and Frequency Laboratory Measurement Units, Standards. (National Metrology Institute) MUSSD-Sri Lanka
Time and Frequency Laboratory Measurement Units, Standards and Services Department (National Metrology Institute) MUSSD-Sri Lanka Introduction Measurement Units, Standards and Services Department (MUSSD
More informationTABLE OF CONTENTS SECTION TITLE PAGE. 5. LIST OF EUT, ACCESSORIES AND TEST EQUIPMENT 10 EUT and Accessory List EMI Test Equipment
Page 2 of 14 TABLE OF CONTENTS SECTION TITLE PAGE GENERAL REPORT SUMMARY 04 SUMMARY OF TEST RESULTS 04 1. PURPOSE 05 2. ADMINISTRATIVE DATA 06 2.1 Location of Testing 06 2.2 Traceability Statement 06 2.3
More informationGage Repeatability and Reproducibility (R&R) Studies. An Introduction to Measurement System Analysis (MSA)
Gage Repeatability and Reproducibility (R&R) Studies An Introduction to Measurement System Analysis (MSA) Agenda Importance of data What is MSA? Measurement Error Sources of Variation Precision (Resolution,
More informationReport on the Activities in Electricity and Magnetism within National Institute of Metrology (NIM), China CCEM 2017
Report on the Activities in Electricity and Magnetism within National Institute of Metrology (NIM), China CCEM 2017 RESEARCH PROGRESS DC&LF 1. Joule Balance The new Joule balance has been mounted by the
More informationCertificate of Calibration No
Federal Department of Justice olice FDJP Federal Office of Metrology METAS Certificate of Calibration No 7-006 Object GPS rcvr type Septentrio PolaRx4TR PRO serial 005 Antenna type Aero AT-675 serial 500
More informationULTRA-PRECISE AIR RESISTANCE STANDARDS
9334A SERIES ULTRA-PRECISE AIR RESISTANCE STANDARDS Very High Stability Calibration Laboratory Resistance Standards GUILDLINE INSTRUMENTS 9334A SERIES of Resistance Standards are designed as very stable
More informationREPORT OF TIME AND FREQUENCY LABORATORY (VIETNAM METROLOGY INSTITUTE)
Nguyen Bang Head of Time and Frequency Laboratory (TFL) Vietnam Metrology Institute (VMI) N 0 8, Hoang Quoc Viet Road, Caugiay District, Hanoi, Vietnam About Time & Frequency Laboratory (TFL) Time and
More informationSignature 1100H+ Performance Verification Manual Version July 11, 2013
1100H+ Performance Verification Manual Version 2013.2.0 July 11, 2013 (ISO 9001 Certified) 1100H+ Performance Verification Manual Version 2013.2.0 Copyright 2013 by Cirris Systems Corporation All Rights
More informationAbout the power standards calibration in the National Institute of Metrology, Romania
About the s calibration in the National nstitute of Metrology, Romania oana Odor 1, Dorin Flaminzeanu 2, Cornel Baltateanu 3, Dan Mihai Stefanescu 4 1 National nstitute of Metrology, Sos. Vitan-Barzesti,
More informationComparison of squareness measurements
Slovenský metrologický ústav Slovak Institute of Metrology Slowakisches Institut für Metrologie EUROMET Supplementary Comparison #910 Comparison of squareness measurements Final Report Jiri Mokros, SMU,
More informationUPGRADE OF THE MEDIUM AND HIGH FREQUENCY VIBRATION CALIBRATION REFERENCE EQUIPMENT AND EXTENSION TO LOW FREQUENCIES
XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 9, Lisbon, Portugal UPGRADE OF THE MEDIUM AND HIGH FREQUENCY VIBRATION CALIBRATION REFERENCE EQUIPMENT AND EXTENSION TO LOW FREQUENCIES
More information2-5 Frequency Calibration
2-5 Frequency SAITO Haruo, IWAMA Tsukasa, TSUCHIYA Shigeru, and KOYAMA Yasuhiro The Japan Standard Time (JST) and the Coordinated Universal Time (UTC(NICT)), which are constructed by National Institute
More informationMetrology Training at the Technical Education and Vocational Training Level
Metrology Training at the Technical Education and Vocational Training Level Mohamed AICHOUNI Mohamed BELEBNA PhD, Assistant Professor Hail College of Technology. Email : m_aichouni@yahoo.co.uk Senior Engineer,
More information8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE
8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE TRANSMILLE LTD. Version 1.1 : Apr 2015 TABLE OF CONTENTS PREPARING FOR CALIBRATION... 4 INTRODUCTION... 4 CALIBRATION INTERVAL SELECTION...
More informationEnhanced Low Dose Rate Sensitivity (ELDRS) Radiation Testing of the RH1498MW Dual Precision Op Amp for Linear Technology
Enhanced Low Dose Rate Sensitivity (ELDRS) Radiation Testing of the RH1498MW Dual Precision Op Amp for Linear Technology Customer: Linear Technology (PO# 54873L) RAD Job Number: 09-579 Part Type Tested:
More informationVersion 1.1 (01/2015) EURAMET e.v. Bundesallee 100 D Braunschweig Germany. Phone:
Authorship and Imprint This document was developed by the EURAMET e.v. Authors: W. Schmid (EURAMET), M. Sega (INRIM, Italy, EURAMET TC-MC Chair), J. Drnovsek (MIRS/UL-FE/LMK, Slovenia, EURAMET Vice-Chairperson
More informationPin photodiode Quality Assurance Procedure
GENEVE, SUISSE GENEVA, SWITZERLAND ORGANISATION EUROPEENE POUR LA RECHERCHE NUCLEAIRE EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH Laboratoire Européen pour la Physique des Particules European Laboratory
More informationClimate Monitoring with GNSS Radio Occultation
Climate Monitoring with GNSS Radio Occultation Stephen Leroy Harvard University Fourth FORMOSAT-3/COSMIC Data Users Workshop University Corporation for Atmospheric Research Boulder, Colorado 27-29 October
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 FUGRO SUHAIMI LIMITED Calibration Laboratory Riyadh Building No.124, Najah Street Ishbiliyah, District Riyadh, Kingdom of Saudi Arabia 31451 Mohammed B. Hameed
More informationCALIBRATION TYPES & CONSIDERATIONS
CALIBRATION TYPES & CONSIDERATIONS 03/12/2018 Introduction One of the most frequently asked questions we receive at Copper Mountain Technologies sales and support departments goes something like this:
More informationVocabulaire international des termes de métrologie légale (VIML)
OIML TC 1 3CD Revision of OIML Vocabulary COMMITTEE DRAFT VIML2 3CD Date: 27 January 2011 Reference number: OIML/TC 1/N 20 Supersedes document: OIML/TC 1/N 16 OIML TC 1 Project p1 Title: International
More informationQuality Systems, Accreditation and the Food Sector
Presentation Outline Quality Systems, Accreditation and the Food Sector David Galsworthy Head of Quality Systems Team Central Science Laboratory York, UK My background The Quality Standards Accreditation
More informationCalibration of High-Voltage Test Equipment
Workshop 2000, Alexandria, Virginia, 13 & 14 September 2000 paper No.: 6 of High-Voltage Test Equipment Uwe Clauss, Stefan Maucksch, HIGHVOLT Prüftechnik Dresden GmbH, Dresden, Germany 1. Abstract The
More informationOP735. Benchtop Optical Power Meter Instruction Manual
Benchtop Optical Power Meter Instruction Manual www.optotest.com 1.805.987.1700 Contacting OptoTest Corporation 1.805.987.1700 (7:30 a.m. to 5 p.m. PST) www.optotest.com engineering@optotest.com OptoTest
More informationEnhanced Low Dose Rate Sensitivity (ELDRS) Radiation Testing of the RH1814MW Quad Op Amp for Linear Technology
Enhanced Low Dose Rate Sensitivity (ELDRS) Radiation Testing of the RH1814MW Quad Op Amp for Linear Technology Customer: Linear Technology (PO 57472L) RAD Job Number: 10-417 Part Type Tested: Linear Technology
More informationRepair & Metrology Services
Repair & Metrology Services Presents SETTING UP A 100kV MEASUREMENT SYSTEM Author: Les Wesson Co-author: Stephan Mare Content 1. Introduction 2. Setting up a suitable area 3. Purchasing equipment 4. DC
More informationEnhanced Low Dose Rate Sensitivity (ELDRS) Radiation Testing of the RH118W Op-Amp for Linear Technology
Enhanced Low Dose Rate Sensitivity (ELDRS) Radiation Testing of the RH118W Op-Amp for Linear Technology Customer: Linear Technology, PO# 60225L RAD Job Number: 11-351 Part Type Tested: RH118W Op-Amp, RH118
More informationLFR: flexible, clip-around current probe for use in power measurements
LFR: flexible, clip-around current probe for use in power measurements These technical notes should be read in conjunction with the LFR short-form datasheet. Power Electronic Measurements Ltd Nottingham
More informationTPS 49 EDITION 2 JUNE 2009
TPS 49 EDITION 2 JUNE 2009 Interim arrangements & guidance on the interpretation of IEC 61672 Sound Level Meters - Periodic Tests CONTENTS SECTION PAGE 1 Purpose and duration 2 2 Statement 2 3 Specific
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 MENTOR TECHNICAL GROUP METROLOGY LAB Caguas Real #100 Alhambra Granada Blvd. Caguas, Puerto Rico Angel Pabellon Phone: 787 536-6028
More information1 Ω 10 kω High Precision Resistance Setup to calibrate Multifunction Electrical instruments
20th IMEKO TC4 International Symposium and 18th International Workshop on ADC Modelling and Testing Research on Electric and Electronic Measurement for the Economic Upturn enevento, Italy, September 15-17,
More informationDC Voltage Linearity Measurements and DVM Calibration with Conventional and Programmable Josephson Voltage Standards
20th IMEKO TC4 International Symposium and 18th International Workshop on ADC Modelling and Testing Research on Electric and Electronic Measurement for the Economic Upturn Benevento, Italy, September 15-17,
More informationModel 6625T Series TEMPERATURE MEASUREMENT SYSTEMS
Model 6625T Series TEMPERATURE MEASUREMENT SYSTEMS Compact Modular and Upgradeable Thermometry Measurement Systems Guildline Instruments 6625T Temperature Measurement System provides demanding users around
More informationGALILEO IOV Results. IWG Meeting 05 Feb 2014, New Delhi, India. Navigation solutions powered by Europe
GALILEO IOV Results IWG Meeting 05 Feb 2014, New Delhi, India Navigation solutions powered by Europe IOV Mission Objectives Verification before full System Deployment: Verification of Space, Ground and
More informationPRECISION INSTRUMENTS FOR TEST AND MEASUREMENT Series. Primary Standard Inductor User and Service Manual
PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT 1482 Series Primary Standard Inductor User and Service Manual Copyright 2018 IET Labs, Inc. Visit www.ietlabs.com for manual revision updates 1482 im/nov.
More informationMEETING ECODESIGN EFFICIENCY REQUIREMENTS: ENSURING ACCURACY IN POWER TRANSFORMER LOSS TESTS VIA TLM SYSTEM CALIBRATIONS
MEETING ECODESIGN EFFICIENCY REQUIREMENTS: ENSURING ACCURACY IN POWER TRANSFORMER LOSS TESTS VIA TLM SYSTEM CALIBRATIONS Gert RIETVELD Ernest HOUTZAGER Milos ACANSKI Dennis HOOGENBOOM VSL, the Netherlands
More informationTutorial on the Statistical Basis of ACE-PT Inc. s Proficiency Testing Schemes
Tutorial on the Statistical Basis of ACE-PT Inc. s Proficiency Testing Schemes Note: For the benefit of those who are not familiar with details of ISO 13528:2015 and with the underlying statistical principles
More informationPXIe Contents. Required Software CALIBRATION PROCEDURE
CALIBRATION PROCEDURE PXIe-5160 This document contains the verification and adjustment procedures for the PXIe-5160. Refer to ni.com/calibration for more information about calibration solutions. Contents
More informationSMART temperature sensors manufactured in standard
1098 IEEE SENSORS JOURNAL, VOL. 10, NO. 6, JUNE 2010 Low-Cost Calibration Techniques for Smart Temperature Sensors Michiel A. P. Pertijs, Member, IEEE, André L. Aita, Student Member, IEEE, Kofi A. A. Makinwa,
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Micro Precision Calibration, Inc. 1 Industrial
More informationEvaluating VNA post-calibration residual errors using the ripple technique at millimetre wavelengths in rectangular waveguide
Evaluating VNA post-calibration residual errors using the ripple technique at millimetre wavelengths in rectangular waveguide Abstract C P Eiø and N M Ridler RF & Microwave Guided Wave Metrology Group,
More information2-3 Calibration of Standard Voltage and Current Generator
2-3 Calibration of Standard Voltage and Current Generator Katsumi FUJII, Kojiro SAKAI, Tsutomu SUGIYAMA, Kouichi SEBATA, and Iwao NISHIYAMA This paper describes the calibration method of standard voltage
More informationA shear beam load cell, with strain gauges, tested as a part of a weighing instrument. Manufacturer : Precia Molen Type : CSI.
Test certificate Page 1 of 4 Issued by Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands Notified Body Number 0122 In accordance with Applicant In respect of Paragraph 8.1 of the European Standard
More informationPRECISION TEMPERATURE SYSTEMS. Compact Modular and Upgradeable Thermometry Measurement Systems
6625T SERIES PRECISION TEMPERATURE SYSTEMS Compact Modular and Upgradeable Thermometry Measurement Systems Guildline Instruments 6625T Temperature Measurement System provides demanding users around the
More information6625A-QHR System COMPLETE QUANTUM HALL RESISTANCE SYSTEM 6625A-QHR FEATURES
6625A-QHR System COMPLETE QUANTUM HALL RESISTANCE SYSTEM Introducing the World s Most Advanced Turn-Key QHR System! GUILDLINE INSTRUMENTS 6625A-QHR SYSTEM has been developed to meet the needs of Standards
More information