Photometry and Light Measurement

Size: px
Start display at page:

Download "Photometry and Light Measurement"

Transcription

1 Photometry and Light Measurement Adrian Waltho, Analytik Ltd

2 What is Light?

3 What is Light?

4 What is Light?

5 Ultraviolet Light UV-C nm UV-B nm UV-A nm

6 Infrared Light NIR Near infrared nm SWIR Short-wave infrared nm MWIR Mid-wave infrared nm LWIR Long-wave infrared nm FIR Far infrared nm

7 What to measure? Photometry (Human Perception) or Radiometry (Physical Energy)

8 Photometry is what we care about today

9 Human Photopic Curve V(λ) The luminosity function V(λ) describes the average spectral sensitivity of human visual perception of brightness. en.wikipedia.org/wiki/luminosity_function Photopic = Bright light Scotopic = Dim light

10 CIE XYZ 1931 The CIE's color matching functions x λ, y λ and z λ are the numerical description of the chromatic response of the observer. They can be thought of as the spectral sensitivity curves of three light detectors yielding the CIE tristimulus values X, Y and Z. Collectively, these three functions are known as the CIE standard observer.

11 CIE degree observer Due to distribution of cones in the eye, the tristimulus values depend on the observer's field of view. To eliminate this variable, the CIE defined a color-mapping function called the standard (colorimetric) observer, to represent an average human's chromatic response within a 2 O arc inside the fovea.

12 ANSI Chromaticity Binning

13 Ideal Black Body Radiator Source: VNIIOFI Institute Moscow

14 Ideal Black Body Radiator hyperphysics.phy-astr.gsu.edu

15 LEDs are NOT Blackbody Radiators!!! Solid state light sources use Electro-luminescence Blackbody light sources use Thermo-luminescence Lux meters, photometers, colorimeters etc. rely on the predictability of blackbody physics When measuring LED solid state light sources, you can t use instruments designed for blackbody sources Need a Spectrometer! How is the Spectis 1.0 Touch different to a lux meter

16 Spectrometer Source CCD

17 Spectrometers measure SPD Spectral Power Distribution Light Power per Wavelength How much blue, green, red light Colour From the SPD we can calculate: Colour (CIE chromaticity co-ordinates) Colour temperature Colour rendering indices Colour quality scale etc. No V(λ) compensation required No Error in calculation New norms and guidelines recommend spectrometers

18 Spectrometers measure SPD

19 Spectrometers measure SPD SPD + Geometry = Useful information Brightness and Colour Illuminance (Lux) = SPD + Cosine corrector Luminous flux (Lumens) = SPD + Sphere Luminance (nits or cd.m -2 ) = SPD + Field of View Gonio-spectrometry = SPD + Angular information

20 WHY Measure LED light? Customers need light measurement at EVERY step in the supply chain

21 Claimed Specifications Source: Photometry Testing, UK

22 Measuring light pre-led Relative Photometry Fluorescent lamp output is constant regardless of what fitting it is put into Predictable behaviour Multiply lamp flux by fitting light output ratio (LOR) to calculate flux of luminaire

23 Measuring LED light Relative Photometry is no longer applicable to solid state lighting LED Output depends on Temperature In turn it depends upon the Thermal design of the fitting For most solid state lighting we have to perform absolute photometry For absolute photometry we need a spectrometer

24 Measuring LED light Source: Y. Zong, NIST Temperature dependence of luminous flux and colour temperature of a high-power white LED

25 Measuring LED light Large Gap exists between LED Manufacturers and Lighting Industry Lumen output and Colour temperature are variable and dependent on multiple factors

26 HOW TO PERFORM LIGHT MEASUREMENT

27 What is your measurement need?

28 How to measure LEDs - Standards Lighting Industry Association Technical Statement 01 - LED/OLED Standards & Guidance Lumileds Optical Measurement Guidelines whitepaper GL Optic Knowledge Base

29 How to measure LEDs - Standards IES LM-79 Electrical and Photometric Measurements of Solid-State Lighting Products Made-do since 2008, de-facto international standard Only North America Lacked worldwide accreditation Other parallel standards active CIE 025/E:2015 Test Method for LED Lamps, LED Luminaires and LED Modules Internationally recognised standard Supersedes LM-79 BS EN 62471:2008 Photo-biological safety of lamps and lamp systems

30 How to measure LEDs - Lux Fast Simple Versatile Colour temperature Colour rendering Colour co-ordinates (binning) Radiometric power (irradiance vs illuminance)

31 How to measure LEDs Lumens or

32 How to measure LEDs Luminous Flux Harder to set up Slower measurement time Larger space needed Colour temperature Colour rendering Full Spatial Information IES / LDT file generation

33 How to measure LEDs Luminous Flux Easy to set up Fast measurement time Inexpensive Colour temperature Colour rendering NO SPATIAL INFORMATION

34 How to measure LEDs Luminous Flux Easy to set up Fast measurement time Inexpensive Colour temperature Colour rendering NO SPATIAL INFORMATION

35 How to measure LEDs Luminous Flux Easy to set up Fast measurement time Inexpensive Colour temperature Colour rendering NO SPATIAL INFORMATION

36 Thermal Considerations Anyone who has designed LED products knows that thermal control is essential to lumen output and product stability (Lifetime). IESNA LM and IESNA LM make reference to controlling temperature on final products: Device Temperature measured at Case Temperature (T s ) Ambient Temperature measured at sphere or within 1m device (for goniometer) and held constant at 25C+/-1C At a minimum, suppliers have to measure Case Temperature of DUT after device stabilization: Stabilization Defined in LM-79: at least 3 readings of light output and electrical power over a period of 30 min. taken 15 minutes apart [with stability] less than 0.5%. This is part of the required report. Ambient Air temperature specified is 25C, but actual environment of device may not be 25C (ex: ASSIST in-ceiling temps of 30-40C). Need to control temp? A more proactive approach is to control DUT temperature (and ambient?) during product development testing and characterization 36

37 How to measure LEDs Luminous Flux

38 How to measure LEDs Luminous Flux NIST Uncertainty in Sphere-Based Measurements (Best on Earth) +/-1% Lumens for White LED products +/ x and y Chromaticity for White LED Products Best Practical Secondary Laboratory Uncertainty +/-1.5-2% Lumens for White LED products +/ x and y Chromaticity for White LED Products Commercial Laboratories +/-3% Lumens for White LED products +/ x and y Chromaticity for White LED Products Good Industry Laboratories and QC +/-5% Lumens for White LED products +/ x and y Chromaticity for White LED Products Practical Production Testing <10% Source: Y. Ohno / NIST, LED 2008 Conference

The Art of Light Measurement. Avantes BV Apeldoorn, The Netherlands

The Art of Light Measurement. Avantes BV Apeldoorn, The Netherlands The Art of Light Measurement Avantes BV Apeldoorn, The Netherlands Who am I? Ger Loop Product Manager Avantes BV Oude Apeldoornseweg 28 7333 NS APELDOORN The Netherlands Phone: (+31) 313 670170 Fax: (+31)

More information

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER Presented by: January, 2015 1 NFMS THEORY AND OVERVIEW Contents Light and Color Theory Light, Spectral Power Distributions, and

More information

Radiometric and Photometric Measurements with TAOS PhotoSensors

Radiometric and Photometric Measurements with TAOS PhotoSensors INTELLIGENT OPTO SENSOR DESIGNER S NUMBER 21 NOTEBOOK Radiometric and Photometric Measurements with TAOS PhotoSensors contributed by Todd Bishop March 12, 2007 ABSTRACT Light Sensing applications use two

More information

Current and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains

Current and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains Measurement Science and Standards (MSS) Current and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains Arnold A. Gaertner Photometry, Radiometry and Thermometry (PRT) CORM 30

More information

12/02/2017. From light to colour spaces. Electromagnetic spectrum. Colour. Correlated colour temperature. Black body radiation.

12/02/2017. From light to colour spaces. Electromagnetic spectrum. Colour. Correlated colour temperature. Black body radiation. From light to colour spaces Light and colour Advanced Graphics Rafal Mantiuk Computer Laboratory, University of Cambridge 1 2 Electromagnetic spectrum Visible light Electromagnetic waves of wavelength

More information

Radiometry vs. Photometry. Radiometric and photometric units

Radiometry vs. Photometry. Radiometric and photometric units Radiometry vs. Photometry Radiometry -- the measurement and specification of the power (energy) of a source of electromagnetic radiation. total energy or numbers of quanta Photometry -- the measurement

More information

IESNA standards on LED and SSL: LM-79, LM-80, and future standards

IESNA standards on LED and SSL: LM-79, LM-80, and future standards CORM 2009 Conference, Gaithersburg, MD, May 6-8, 2009 IESNA standards on LED and SSL: LM-79, LM-80, and future standards Yoshi Ohno Director of CIE Division 2 Member of ANSI C78-09, IESNA TPC National

More information

Radiometry vs. Photometry. Radiometric and photometric units

Radiometry vs. Photometry. Radiometric and photometric units Radiometry vs. Photometry Radiometry -- the measurement and specification of the power (energy) of a source of electromagnetic radiation.! total energy or numbers of quanta Photometry -- the measurement

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB03176 PAGE: 1 OF 9 LUMINAIRE: CAST WHITE PAINTED FINNED METAL HEAT SINK,SHEETMETAL JUNCTION BOX AFFIXED TO TOP OF HEATSINK, 1 CIRCUIT BOARD WITH 10 LEDS. LAMPS: TEN WHITE MULTI-CHIP LIGHT

More information

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard Lamp specifics: Luminaire Used: none none Rated Watts Voltage: 6.75 Watts Lamp Type: LPL-W18-120C-930 / 78875 / Rated Orientation CCT: VBD Test Requester E.Z. Cola Rated Voltage 12 V DC New Product: 1

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB02177 PAGE: 1 OF 7 CATALOG NUMBER: SK21XL25RYY LUMINAIRE: STAMPED STEEL CEILING PAN WITH WHITE FINISH, 10 LED BOARDS EACH WITH 10 LEDS, ACRYLIC DROP LENS WITH SMOOTH FINISH. LAMPS: ONE-HUNDRED

More information

LED14.5WPAR30S/FL/827-DIM

LED14.5WPAR30S/FL/827-DIM LED14.5WPAR30S/FL/827-DIM TABLE OF CONTENTS 1 - GENERAL INFORMATION... 3 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)... 3 1.2 OBJECTIVE... 3 1.3 TEST FACILITY DESCRIPTION... 4 1.4 TEST EQUIPMENT

More information

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L540-C27-B25 tel: fax: lm x 0.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L540-C27-B25 tel: fax: lm x 0. Total Integrated Radiant Flux Total Integrated Luminous Flux Luminous Efficacy Peak Wavelength Dominant Wavelength Color Purity CCT CRI Ra Peak Candela Irradiance (W/m 2 *nm) Figure 3 Spectral Illuminance

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB03414 PAGE: 1 OF 9 LUMINAIRE: EXTRUDED METAL HOUSING WITH HEAT SINK FINS, TWO WHITE CIRCUIT BOARD WITH THREE HUNDRED LEDS ON EACH BOARD, METAL REFLECTOR WITH SPECULAR FINISH, FLAT TRANSLUCENT

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB03145 PAGE: 1 OF 9 LUMINAIRE: EXTRUDED METAL HOUSING WITH HEAT SINK FINS, TWO WHITE CIRCUIT BOARD WITH THREE HUNDRED LEDS ON EACH BOARD, METAL REFLECTOR WITH SPECULAR FINISH, FLAT TRANSLUCENT

More information

IESNA LM (NOT INCLUDE SPATIAL NON-UNIFORMITY OF CHROMATICITY) ELECTRICAL AND PHOTOMETRIC MEASUREMENTS OF SOLID-STATE LIGHTING PRODUCTS

IESNA LM (NOT INCLUDE SPATIAL NON-UNIFORMITY OF CHROMATICITY) ELECTRICAL AND PHOTOMETRIC MEASUREMENTS OF SOLID-STATE LIGHTING PRODUCTS IESNA LM-79-08 (NOT INCLUDE SPATIAL NON-UNIFORMITY OF CHROMATICITY) ELECTRICAL AND PHOTOMETRIC MEASUREMENTS OF SOLID-STATE LIGHTING PRODUCTS MEASUREMENT AND TEST REPORT For ELEC-TECH INTERNATIONAL CO.,

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB01271 PAGE: 1 OF 5 LUMINAIRE: LUMINAIRE: FABRICATED WHITE PAINTED METAL HOUSING, 4 WHITE CIRCUIT BOARDS EACH WITH 120 LEDS, FROSTED HOLOGRAPHIC PLASTIC LENS. LENS FROSTED SIDE UP. LAMPS:

More information

Horticultural Lighting Test Report

Horticultural Lighting Test Report Horticultural Lighting Test Report Relevant Standards IES LM-79-2008 ANSI C78.377-2011, ANSI C82.77-2002 CIE 13.3-1995, CIE 15-2004, IES TM-30-15 Prepared For Smart Grow Technologies 69319 Panoramic Dr

More information

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model: LM-79-08 Test Report for Philips (China) Investment Co., Ltd. Building 9, Lane 888, Tianlin Road Shanghai, China InstantFit LEDtube Model: 9290002840 Laboratory: Leading Testing Laboratories NVLAP CODE:

More information

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: MLLWP40LED50DS Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 96.2 3353.0 34.85 0.9900 CCT (K) CRI Stabilization Time (Light & Power)

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB01842 PAGE: 1 OF 6 CATALOG NUMBER: SWISH2X2-29YN/D10 LUMINAIRE: WHITE PAINTED SHEET METAL HOUSING, 2 WHITE CIRCUIT BOARDS EACH WITH 60 LEDS, FROSTED POLYCARBONATE LENS IN THE CENTER,

More information

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: MLFP24DS4241/SD Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.6 4723.5 43.49 0.9902 CCT (K) CRI Stabilization Time (Light & Power)

More information

Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:

Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date: IES LM 79 08 Test Report Test results reported for: report: Original issue date: LED Lamp 001 LEDC001 010 WG 1 January 2012 Prepared for: Testing performed by: LED ABC, Inc. Memorial Highway 1003 7th Ave.

More information

Photometry for Traffic Engineers...

Photometry for Traffic Engineers... Photometry for Traffic Engineers... Workshop presented at the annual meeting of the Transportation Research Board in January 2000 by Frank Schieber Heimstra Human Factors Laboratories University of South

More information

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L600-C30-B25 tel: fax: lm x 0.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L600-C30-B25 tel: fax: lm x 0. Total Integrated Radiant Flux Total Integrated Luminous Flux Luminous Efficacy Peak Wavelength Dominant Wavelength Color Purity CCT CRI Ra Peak Candela Irradiance (W/m 2 *nm) Figure 3 Spectral Illuminance

More information

Properties of LED considering museum lighting

Properties of LED considering museum lighting Properties of LED considering museum lighting Carsten Dam-Hansen, DTU Fotonik Contents Solid State Lighting (SSL) i.e. LED based lighting is a new lighting technology that may offer many advantages for

More information

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P20-L360-C27-B25 tel: fax: lm x 0.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P20-L360-C27-B25 tel: fax: lm x 0. Total Integrated Radiant Flux Total Integrated Luminous Flux Luminous Efficacy Peak Wavelength Dominant Wavelength Color Purity CCT CRI Ra Peak Candela Irradiance (W/m 2 *nm) Figure 3 Spectral Illuminance

More information

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR IESNA LM-79: 2008 Measurement and Test Report for EiKO Global, LLC Sep 09, 2013 Product Name: LED Model No: LED8WMR16/38/830-DIM Test Engineer: David Zhang Report No.: BTR66.181.13.1294.01-1 Sample Received

More information

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: L15T8SE450-G Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 125.1 1904.0 15.22 0.9679 CCT (K) CRI Stabilization Time (Light & Power)

More information

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006 LM-79-08 Test Report For Maxlite INC (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): MLFP24EP50XX Remark: The

More information

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 2*4 Retrofit Kits Model: RKT4514U5550DV Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806

More information

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ LM-79-08 Test Report For Maxlite Inc (Brand Name: ) 12 York Avenue, West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO84040W Test & Report By: Johnson Sun Engineer: Johnson Sun Date: Jun.10,2015

More information

Diogen Lighting,Inc 14 Inverness Drive East,Ste.E-128 Englewood, CO T8L W BEST Test Service Shenzhen Co., Ltd.

Diogen Lighting,Inc 14 Inverness Drive East,Ste.E-128 Englewood, CO T8L W BEST Test Service Shenzhen Co., Ltd. IESNA LM-79: 2008 Measurement and Test Report for 14 Inverness Drive East,Ste.E-128 Englewood, CO 80112 Jun 15, 2011 Product Name: T8 Tube Model No: T8L1200-18W-02-120-32 Test Engineer: David Zhang Report

More information

Measuring colour in a world of light

Measuring colour in a world of light Measuring colour in a world of light 1 Contents 1 Measuring colour in a world of light 5 2 The power of light 7 2.1 What is light? 7 2.2 Measuring light 9 2.3 Optical configurations 10 2.3.1 Integrating

More information

Properties of LED considering museum lighting

Properties of LED considering museum lighting Downloaded from orbit.dtu.dk on: Jan 05, 2019 Properties of LED considering museum lighting Dam-Hansen, Carsten Publication date: 2015 Document Version Peer reviewed version Link back to DTU Orbit Citation

More information

Checked X.CAO

Checked X.CAO REPORT NUMBER: RAB01900 PAGE: 1 OF 7 CATALOG NUMBER: BULLET12Y LUMINAIRE: CAST FINNED METAL HEAT SINK, MOLDED TEXTURED PLASTIC REFLECTOR WITH SEMI-DIFFUSE FINISH, 1 CIRCUIT BOARD WITH 24 LEDS, CLEAR MICRO-PRISMATIC

More information

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014 IESNA LM-79: 2008 Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE Dec 08, 2014 Product Name: LED Model No: 82031 Test Engineer: David Zhang Report No.: BTR66.181.14.0039.06

More information

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50 LM-79-08 Test Report for Maxlite Inc. 12 York Ave West Caldwell NJ 07006 LED Canopy Model: MLCAN20LED50 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com

More information

GL spectis 1.0 Touch The world s first smart spectrometer.

GL spectis 1.0 Touch The world s first smart spectrometer. TM Touch the technology GL spectis 1.0 Touch The world s first smart spectrometer. Enter the world of smart spectrometers GL Optic offers a complete line of measuring instruments using the latest smart

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Transverse Distance in Units of Mounting Heights Street Side House Side 2 1 0 1 2 1.5.2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 25 foot mounting height. 11 1/2 17 7/8 11 0 11 REPORT

More information

Visibility, Performance and Perception. Cooper Lighting

Visibility, Performance and Perception. Cooper Lighting Visibility, Performance and Perception Kenneth Siderius BSc, MIES, LC, LG Cooper Lighting 1 Vision It has been found that the ability to recognize detail varies with respect to four physical factors: 1.Contrast

More information

Photometry for Traffic Engineers...

Photometry for Traffic Engineers... Photometry for Traffic Engineers... Workshop presented at the annual meeting of the Transportation Research Board in January 2000 by Frank Schieber Heimstra Human Factors Laboratories University of South

More information

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA.

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA. IESNA LM-79: 2008 Measurement and Test Report for Jiawei Technology (USA) Limited 2305 Lincoln Ave.Hayward, CA 94545 USA Apr 03, 2015 Product Name: self-ballast LED Lamp Model No: DL-9PAR30-830-LN-25-D;ML-9PAR30-830-LN-25-D

More information

Checked X.CAO

Checked X.CAO REPORT NUMBER: RAB02068 PAGE: 1 OF 7 CATALOG NUMBER: FXLED78SF - FXLED78T (SF=SLIPFITTER MOUNT & T=TRUNNION MOUNT) LUMINAIRE: CAST FINNED METAL HOUSING, MOLDED PLASTIC REFLECTOR WITH SPECULAR FINISH AND

More information

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: T8FR17/835/DIR/LED Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts)/2 Power Factor 105.4 1761.0 16.70 0.9970 CCT (K) CRI Stabilization Time (Light

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Transverse Distance in Units of Mounting Heights Street Side House Side 2 1 0 1.2.5 1 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 25 foot mounting height. 11 1/2 17 7/8 11 0.1.05.02.01.005

More information

LM-79 Test Report. GE Infusion M1000/830/W/N. Electrical and Photometric tests as required by IESNA LM-79 test standard

LM-79 Test Report. GE Infusion M1000/830/W/N. Electrical and Photometric tests as required by IESNA LM-79 test standard specifics: Luminaire Used: SRTGLEDGI SRTGLEDGI 15W 30K WD E1 GES66 15W 30KRated Voltage: Watts 15 watt Driver Type: Roal Strato GE RSLD035-7A Infusion M1000/83 Rated CCT: Orientation VBU GE Infusion M1000/830/W/N

More information

Test Report. Report No.: EED35I Page 1 of 10. Customer : EIKO GLOBAL LLC Address : W 84TH ST SHAWNEE, KS USA

Test Report. Report No.: EED35I Page 1 of 10. Customer : EIKO GLOBAL LLC Address : W 84TH ST SHAWNEE, KS USA Report No.: EED35I000287-1 Page 1 of 10 Customer : EIKO GLOBAL LLC Address : 23220 W 84TH ST SHAWNEE, KS 66227 USA Description of the submitted sample(s): Sample Name : LED Tube Model/Type : LED9W4PH/830DR-G6

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ LM-79-08 Test Report For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO61840W Representative (Tested) Model: RRECO61840W Test & Report By: Johnson

More information

Lighting Terminologies Introduction

Lighting Terminologies Introduction Lighting Terminologies Introduction A basic understanding of lighting fundamentals is essential for specifiers and decision makers who make decisions about lighting design, installation and upgrades. Radiometry

More information

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration Technical Notes Integrating Sphere Measurement Part II: Calibration This Technical Note is Part II in a three part series examining the proper maintenance and use of integrating sphere light measurement

More information

LM-79 Test Report. GE Infusion M2000/830/W/N. Electrical and Photometric tests as required by IESNA LM-79 test standard

LM-79 Test Report. GE Infusion M2000/830/W/N. Electrical and Photometric tests as required by IESNA LM-79 test standard specifics: Luminaire Used: SGE4SQLEDGI SGE4SQLEDGI 30W 30K ND E1 AR0204LGI 30W 3SG Rated FGCC Voltage: Watts 30 watt Driver Type: Roal Strato GE RSLD035-07 Infusion M2000/83 Rated CCT: Orientation VBU

More information

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED Lighting) Rm 1902, Easey Comm Bldg 253-261 Hennessy Rd Wanchai, HONG KONG LED Tube Light Model name(s): HC-T8-8FT-36W-ID(Clear) Representative

More information

True energy-efficient lighting: the fundamentals of lighting, lamps and energy-efficient lighting

True energy-efficient lighting: the fundamentals of lighting, lamps and energy-efficient lighting True energy-efficient lighting: the fundamentals of lighting, lamps and energy-efficient lighting by Prof Wilhelm Leuschner and Lynette van der Westhuizen Energy efficiency and saving electrical energy

More information

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: KT-PLED50-24-850-VDIM /G2 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 117.9 6083.5 51.62 0.9926 CCT (K) CRI Stabilization Time (Light

More information

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG 57-100W-XXK-WPH12-SG 57-100W-40K-WPH12-SG 57-100W-57K-WPH12-SG Eternal Shine Technology Co.,Ltd. EST 57-100W-XXK-WPH12-SG 1.2 Test Specifications: Date of Receipt Date of Test Test item Reference Standard

More information

Report No.: EASZE Page 2 of 14

Report No.: EASZE Page 2 of 14 Report No.: EASZE03220005 Page 2 of 14 1 SUMMARY Parameter Result Total Luminous Flux 1680.9 lm Luminous Efficacy 83.34 lm/w Power Factor 0.9829 Color Rendering Index (Ra) 83.7 Correlated Color Temperature

More information

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary Test Summary Sample Tested: LFC41327W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 45.3 544.6 12.02 0.9892 CCT Stabilization Time CRI (K) (Light & Power)

More information

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary Test Summary Sample Tested: ML4LS10SOLBK Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 55.2 552.2 10.01 0.9797 CCT Stabilization Time CRI (K) (Light & Power)

More information

Development of 2 Total Spectral Radiant Flux Standards at NIST

Development of 2 Total Spectral Radiant Flux Standards at NIST CIE/USA Annual Conference, October 7, 2014, Seattle, WA Development of 2 Total Spectral Radiant Flux Standards at NIST Yuqin Zong National Institute of Standards and Technology Gaithersburg, Maryland Outline

More information

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 100402-0.. REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 Project No. G101555841 Date: March 21, 2014 REPORT NO. 101555841CRT-001 TEST OF ONE LED

More information

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 WALLPACK Model: MLSWP30LED50DS Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com

More information

Guidance Note 7/17. Choosing the right photometer/illuminance meter

Guidance Note 7/17. Choosing the right photometer/illuminance meter Choosing the right photometer/illuminance meter Copyright 2017 ILP All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form or by any

More information

specification display & lighting hera spectrometer

specification display & lighting hera spectrometer specification display & lighting hera spectrometer Contents 1 Hera: cost effective spectrometer... 3 2 Highlights... 3 3 Speed & ease of use... 4 1 General specification Hera... 4 2 Hera series specifications...

More information

GL SPECTIS 1.0 Touch The world s first smart spectrometer

GL SPECTIS 1.0 Touch The world s first smart spectrometer Touch the technology GL SPECTIS 1.0 Touch The world s first smart spectrometer lx, lm, fc, cd, cd/m2, mwatt CRI, CCT, Color, peak wavelength IF YOU NEED TO MEASURE: illumination value - Lux luminous flux

More information

illumia Plus Temperature Controlled Light Measurement Systems

illumia Plus Temperature Controlled Light Measurement Systems illumia Plus Temperature Controlled Light Measurement Systems Allows testing over a broad range of temperatures Measure with Confidence When a solid-state light engine is used in a luminaire or fixture,

More information

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP50AUT550BPCMA BLP50AUT530BPCMA Representative (Tested)

More information

Report No.: HZ c

Report No.: HZ c Test Summary Model L13T8DF450-CG4 Luminous Efficacy (Lumens /Watt) 121.4 Total Luminous Flux (Lumens) 2038.0 Power (Watts)/2 16.79 Power Factor 0.9957 CCT (K) 4912 CRI 81.5 Stabilization Time (Light &

More information

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary Test Summary Sample Tested: LFC61541W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 63.3 988.8 15.61 0.9810 CCT Stabilization Time CRI (K) (Light & Power)

More information

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR Quality Assured NVLAP LAB CODE 200960-0 L 1-79-08 Test Report for EIKO GLOBAL, LLC 23220 W 84th Street, Shawnee, KS 66227 LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR Laboratory: Leading Testing Laboratories

More information

BGS400 Lamp & Luminaire Goniophotometer (C-γ, B-ß Plane)

BGS400 Lamp & Luminaire Goniophotometer (C-γ, B-ß Plane) BGS400 Lamp & Luminaire Goniophotometer (C-γ, B-ß Plane) BGS400 Luminaire Goniophotometer (C-γ, B-ß Plane ) The BGS400 moving lamp and luminaire gonio-photometer is an economical, turnkey solution for

More information

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: FLS50U50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.1 5291.8 48.96 0.9859 CCT (K) CRI Stabilization Time (Light & Power) 5119

More information

Spectral Handheld Light Meters for accurate measurements of LED lighting. Mike Clark, Gigahertz-Optik GmbH on behalf of Te Lintelo Systems BV

Spectral Handheld Light Meters for accurate measurements of LED lighting. Mike Clark, Gigahertz-Optik GmbH on behalf of Te Lintelo Systems BV Spectral Handheld Light Meters for accurate measurements of LED lighting Mike Clark, Gigahertz-Optik GmbH on behalf of Te Lintelo Systems BV www.gigahertz-optik.de www.tlsbv.nl Talk Aims What are the weaknesses

More information

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG IESNA LM-79: 2008 Measurement and Test Report for Green Creative Ltd. Room 1206-7, New Victory House, 93-103 Wing Lok Street, Central, HONG KONG Sep 02,2013 Product Name: LED PAR30 Model No: 14PAR30G3DIM/827FL40

More information

Photometric Indoor Test Report

Photometric Indoor Test Report Photometric Indoor Test Report Relevant Standards LM-79-28 Prepared For Sea Gull Lighting Andre Duljas 31 W. Washington Street Riverside, NJ 875 Catalog Number 96118S-32 LTL Test Number 2191 Test Date

More information

IES LM Report. Technical Requirements Table, V4.0, DLC Premium DesignLights Consortium Product Application Category

IES LM Report. Technical Requirements Table, V4.0, DLC Premium DesignLights Consortium Product Application Category IES LM-79-08 Report Partner: Partner Company Name Zhongshan Luxmode Industrial CO., LTD. Manufacturer/ OEM name (if different) Zhongshan Luxmode Industrial CO., LTD. Primary Contact Name Kevin Chao kevin.wlc@luxmodecorp.com

More information

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report For EIKO GLOBAL, LLC 23220 W 84th Street, Shawnee, KS 66227 T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D Laboratory: Leading Testing Laboratories

More information

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report for EiKO Global, LLC 23220 W. 84th St. Shawnee, KS 66227 25W Floodlight Model: FLM-2C-N-U Laboratory: Leading Testing Laboratories NVLAP CODE:

More information

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-50W Representative (Tested) Model: WML-50NW WML-50CW Model Different: All construction and rating

More information

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: WPL40AU50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 91.6 3480.4 37.99 0.9907 CCT (K) CRI Stabilization Time (Light & Power) 5257

More information

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires LM-79-08 Test Report For Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): Remark: The suffix X can be A, B, B2, C, C2, D, D2, E, E2, F, F2 representing different mounting bracket; Y

More information

power light source Technical Datasheet DS46 Luxeon III is rated for up to 1000mA operation, delivering increased lumens per package.

power light source Technical Datasheet DS46 Luxeon III is rated for up to 1000mA operation, delivering increased lumens per package. power light source Luxeon III Star Technical Datasheet DS46 Luxeon III is a revolutionary, energy efficient and ultra compact new light source, combining the lifetime and reliability advantages of Light

More information

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWA-50W Remark: X=CCT(3=3000K,4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits to indicate

More information

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA LM-79-08 Test Report For FALKOR INDUSTRY INC (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA 90201 USA High-bay Luminaires for Commercial and Industrial Buildings Model name(s): FI-HB-2FT-110W

More information

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: LDP2450L35U1 2X4 3500K Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 102.3 5129.5 50.12 0.9883 CCT (K) CRI Stabilization Time (Light

More information

Eternal Shine Technology Co.,Ltd. EST

Eternal Shine Technology Co.,Ltd. EST Eternal Shine Technology Co.,Ltd. EST NO.7 Flood, Bldg A,Shenfubao Industry Park, Bonded area, Futian District,Shenzhen, China 57-40W-XXK-WPH06-SG 57-40W-40K-WPH06-SG 57-40W-57K-WPH06-SG Eternal Shine

More information

Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting

Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting MSC15 http://www.gigahertz-optik.de/en-us/product/msc15 Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting Gigahertz-Optik

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards RIES LM-79-2008 RANSI C82.77:2014 Prepared For RAB LIGHTING INC 170 Ludlow Ave, PO BOX 970, Northvale, NJ 07647-2305 USA Crystal Wu 13482123342, Crystal.Wu@rabweb.com

More information

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-30W Remark: X=CCT(4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits

More information

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: 8PLE26LED35 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 101.5 707.7 6.97 0.9815 CCT (K) CRI Stabilization Time (Light & Power) 3498

More information

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G101183506 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. Date: June 6, 2013 REPORT NO. 101183506CRT-001 TEST OF ONE LED FLOOD

More information

Report No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary

Report No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary Test Summary Model MT8N28 Luminous Efficacy (Lumens /Watt) 101.5 Total Luminous Flux (Lumens) 1860.0 Power (Watts)/2 18.32 Power Factor 0.9972 CCT (K) 3948 CRI 82.9 Stabilization Time (Light & Power) 60

More information

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS LM-79-08 Test Report For EIKO GLOBAL, LLC 23220 W 84th St., Shawnee, KS 66227. Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): WPT1-55/8XX-BZ-U Remark:The letter X in the model name stands

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards RIES LM-79-2008 RANSI C82.77:2014 Prepared For RAB LIGHTING INC 170 Ludlow Ave, PO BOX 970, Northvale, NJ 07647-2305 USA Crystal Wu 13482123342, Crystal.Wu@rabweb.com

More information

LM Test. for LED. Cabinet

LM Test. for LED. Cabinet LM-79-08 Test Report for ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, ZhuhaiCity, Guangdong Province, P.R. China 5190855 LED Cabinet Light Model: 535021## #(##=11-30)

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008, ANSI C82.77-2002, CIE 13.3-1995 CIE 15-2004, ANSI C78.377-2015, IES TM-30-2015 Prepared For Smart Grow Technologies 69319 Panoramic Dr Sisters,

More information

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A LM-79-08 Test Report for Elec-Tech International Co., Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China BR40 LAMP Model: 525021XX(XX:01-10), WBR40L27S2A Laboratory:

More information

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG IESNA LM-79: 2008 Measurement and Test Report for Green Creative Ltd. Room 1206-7, New Victory House, 93-103 Wing Lok Street, Central, HONG KONG Apr03,2013 Product Name: [MR16 Model No: [01-715-0/840-380

More information

Report No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample

Report No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample Test Summary Sample Tested: AR-MAL100UT3-40X Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 131.6 12593.0 95.69 0.9967 CCT (K) CRI Stabilization Time (Light &

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED PAR30 Spot light Model: 524142XX(XX:41-50) Laboratory:

More information