Report No.: EASZE Page 2 of 14
|
|
- Kathleen Powers
- 5 years ago
- Views:
Transcription
1
2 Report No.: EASZE Page 2 of 14 1 SUMMARY Parameter Result Total Luminous Flux lm Luminous Efficacy lm/w Power Factor Color Rendering Index (Ra) 83.7 Correlated Color Temperature (CCT) 3210 K (x) (y) (u') (v') Spatial Non-uniformity of ( u'v') EQUIPMENT LIST Test Equipment Model Equipment No. Calibration Date Calibration Due Date Goniophotometer GO-R5000 ATTEELSH00105 Oct. 11, 2011 Oct. 10, 2012 Gonio-spectroradiometer HAAS-2000 ATTEELSH00105 Oct. 11, 2011 Oct. 10, 2012 Digital Power Meter PF2010A ATTEELSH00107 Dec. 02, 2011 Dec. 01, 2012
3 Report No.: EASZE Page 3 of 14 3 TEST METHODS 3.1 Requirements of Ambient Condition The ambient temperature in which measurements are being taken shall be maintained at 25 ± 1, measured at a point not more than 1 m from the SSL product and at the same height as the SSL product. Air flow around the SSL product being tested should be such that normal convective air flow induced by device under test is not affected. 3.2 Seasoning of SSL Product For the purpose of rating new SSL products, SSL products shall be tested with no seasoning. Therefore, no seasoning was performed. 3.3 Stabilization of SSL Product Before measurements are taken, the SSL product under test shall be operated long enough to reach stabilization and temperature equilibrium. The time required for stabilization depends on the type of SSL products under test. The stabilization time typically ranges from 30 minutes for small integrated LED lamps to 2 or more hours for large SSL luminaires. It can be judged that stability is reached when the variation (maximum minimum) of at least 3 readings of the light output and electrical power over a period of 30 minutes, taken 15 minutes apart, is less than 0.5%. Therefore, the stabilization time of the sample was 1 hour, and the total operating time including stabilization was 3 hours. 3.4 Operating Orientation The SSL product under test shall be evaluated in the operating orientation recommended by the manufacturer for an intended use of the SSL product. Stabilization and photometric measurements of SSL products shall be done in such operating orientation. Therefore, the orientation of the sample as mounted for measurement was shown in Section 4.2 figure. 3.5 Photometric and Electrical Measurements - Goniophotometer Method An EVERFINE Type C Model GO-R5000 Goniophotometer was used to measure the intensity at each angle of distribution for each sample. The photometric distance is 2.1m for near-field measurement or 26m for far-field measurement. Ambient temperature was measured at the same height of the sample mounted on the Goniophotometer equipment. Electrical measurements including voltage, current, and power were measured using the Digital Power Meter. Some graphics were created with Photometric Plus software.
4 Report No.: EASZE Page 4 of Color Characteristics Measurements The color characteristics of SSL products include chromaticity coordinates, correlated color temperature, and color rendering index. These characteristics of SSL products may be spatially non-uniform, and thus, in order that they can be specified accurately, the color quantities shall be measured as values that are spatially average, weighted to intensity, over the angular range where light is intentionally emitted from the SSL product. The color characteristics measurements are using gonio-spectroradiometer. 3.7 Color Spatial Uniformity The characteristics of SSL products may be spatially non-uniform, the chromaticity coordinate shall be measured at two vertical planes (C=0 /180 and C=90 /270 ) and at 10 or less intervals for vertical angle until the light output dropped to below 10% of the peak intensity. The averaged weighted chromaticity coordinate was calculated from these points. The data was then analyzed to check for delta color differences of the u', v' chromaticity coordinates. The spatial non-uniformity of chromaticity, u'v', is determined as the maximum deviation (distance on the CIE (u', v') diagram) among all measured points from the spatially averaged chromaticity coordinate. The geometry for the chromaticity measurement using gonio-spectroradiometer is shown as following.
5 Report No.: EASZE Page 5 of 14 4 TEST RESULTS 4.1 Photometric and Electrical Measurements at 25 Sample Model Voltage (Vac) Current (A) Power (W) Power Factor L05G 1200MM Total Luminous Luminous Correlated Color Color Rendering Sample Model Flux Efficacy Temperature Index (lm) (lm/w) (K) / CRI L05G 1200MM Sample Model x y u' v' L05G 1200MM Note: According to CIE 1976 (u',v') diagram, u' = u = 4x/(-2x+12y+3), v' = 3v/2 = 9y/(-2x+12y+3).
6 Report No.: EASZE Page 6 of Luminous Intensity Distribution
7 Report No.: EASZE Page 7 of Luminous Intensity Data
8 Report No.: EASZE Page 8 of 14
9 Report No.: EASZE Page 9 of Zonal Lumen Density
10 Report No.: EASZE Page 10 of Planar Illuminance Curve
11 Report No.: EASZE Page 11 of Color Spatial Uniformity C Angle = 0 /180 C Angle = 90 /270 γ Angle ( ) Luminous Intensity (cd) u' v' Luminous Intensity (cd) u' v' Weighted Average u' v'
12 Report No.: EASZE Page 12 of 14 γ Angle ( ) C Angle = 0 /180 C Angle = 90 /270 u' v' u' v' Spatial non-uniformity of chromaticity u'v':
13 Report No.: EASZE Page 13 of 14 Photos of the sample Fig.1- Overall view Fig.2- Back view
14 Report No.: EASZE Page 14 of 14 Fig.3- Partial view *** End of Report *** This report is considered invalidated without the Special Seal for Inspection of the CTI. This report shall not be altered, increased or deleted. The results shown in this test report refer only to the sample(s) tested. Without written approval of CTI, this test report shall not be copied except in full and published as advertisement.
Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: LDP2450L35U1 2X4 3500K Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 102.3 5129.5 50.12 0.9883 CCT (K) CRI Stabilization Time (Light
More informationReport No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: KT-PLED50-24-850-VDIM /G2 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 117.9 6083.5 51.62 0.9926 CCT (K) CRI Stabilization Time (Light
More informationReport No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: FLS50U50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.1 5291.8 48.96 0.9859 CCT (K) CRI Stabilization Time (Light & Power) 5119
More informationReport No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: WPL40AU50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 91.6 3480.4 37.99 0.9907 CCT (K) CRI Stabilization Time (Light & Power) 5257
More information(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary
Test Summary Sample Tested: LFC61541W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 63.3 988.8 15.61 0.9810 CCT Stabilization Time CRI (K) (Light & Power)
More informationReport No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: MLFP24DS4241/SD Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.6 4723.5 43.49 0.9902 CCT (K) CRI Stabilization Time (Light & Power)
More information(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary
Test Summary Sample Tested: LFC41327W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 45.3 544.6 12.02 0.9892 CCT Stabilization Time CRI (K) (Light & Power)
More informationReport No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: MLLWP40LED50DS Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 96.2 3353.0 34.85 0.9900 CCT (K) CRI Stabilization Time (Light & Power)
More informationLM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50
LM-79-08 Test Report for Maxlite Inc. 12 York Ave West Caldwell NJ 07006 LED Canopy Model: MLCAN20LED50 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com
More informationReport No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: L15T8SE450-G Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 125.1 1904.0 15.22 0.9679 CCT (K) CRI Stabilization Time (Light & Power)
More informationReport No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample
Test Summary Sample Tested: AR-MAL100UT3-40X Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 131.6 12593.0 95.69 0.9967 CCT (K) CRI Stabilization Time (Light &
More informationLM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U
Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report for EiKO Global, LLC 23220 W. 84th St. Shawnee, KS 66227 25W Floodlight Model: FLM-2C-N-U Laboratory: Leading Testing Laboratories NVLAP CODE:
More informationLM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV
LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 2*4 Retrofit Kits Model: RKT4514U5550DV Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806
More informationReport No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: T8FR17/835/DIR/LED Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts)/2 Power Factor 105.4 1761.0 16.70 0.9970 CCT (K) CRI Stabilization Time (Light
More informationLM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS
LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 WALLPACK Model: MLSWP30LED50DS Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com
More informationTest Report. Report No.: EED35I Page 1 of 10. Customer : EIKO GLOBAL LLC Address : W 84TH ST SHAWNEE, KS USA
Report No.: EED35I000287-1 Page 1 of 10 Customer : EIKO GLOBAL LLC Address : 23220 W 84TH ST SHAWNEE, KS 66227 USA Description of the submitted sample(s): Sample Name : LED Tube Model/Type : LED9W4PH/830DR-G6
More informationReport No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: 8PLE26LED35 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 101.5 707.7 6.97 0.9815 CCT (K) CRI Stabilization Time (Light & Power) 3498
More informationLM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:
LM-79-08 Test Report for Philips (China) Investment Co., Ltd. Building 9, Lane 888, Tianlin Road Shanghai, China InstantFit LEDtube Model: 9290002840 Laboratory: Leading Testing Laboratories NVLAP CODE:
More informationMorris Products 53 Carey Road, Queensbury, NY 12804
Catalog Number 71462 UPC Number 60198671462 Description LED Vandal Resistant Canopy Light 40W Voltage: 120/277 Features Corrosion Die Cast Aluminum Housing Prismatic Polycarbonate Lens Superior Architectural
More informationCat# LED Classic Large Wall-Pack
Cat# 71440 LED Classic Large Wall-Pack OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC OTHERS Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency
More informationLM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)
LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540751XX(XX: 01-10) Laboratory:
More informationLM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)
LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540751XX(XX: 61-70) Laboratory:
More informationLM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)
LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540741XX(XX: 01-10) Laboratory:
More informationCatalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White
Catalog Number 71694 UPC Number 60198671694 Description LED Spot Bullet Flood Light 42W 4204 Lumens White QPL ID # PWG6GTSQ Features Philips Lumiled LUXEON 3030 2D Voltage: 120-277VAC Isolated Driver Compartment
More informationLM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)
LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED PAR30 Spot light Model: 524142XX(XX:41-50) Laboratory:
More informationLM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A
LM-79-08 Test Report for Elec-Tech International Co., Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China BR40 LAMP Model: 525021XX(XX:01-10), WBR40L27S2A Laboratory:
More informationCatalog Number UPC Number LED Spot Bullet Flood Light 15W 1620 Lumens Bronze
Catalog Number 71679 UPC Number 60198671679 Description LED Spot Bullet Flood Light 15W 1620 Lumens Bronze QPL ID # PJMW56XK Features Philips Lumiled LUXEON 3030 2D Voltage: 120-277VAC Isolated Driver
More informationReport No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary
Test Summary Sample Tested: ML4LS10SOLBK Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 55.2 552.2 10.01 0.9797 CCT Stabilization Time CRI (K) (Light & Power)
More informationVAC 60HZ A 120V; 0..18A 277V 40W PF ,000 LM 125 LM/W >82 <19. Arcata VDC 1.2A 120V 88% Edison
71781 2X2 LED Troffer RoHS 0-10V Dimmable QPL ID # PR3BFQPW Model: 71781 Input Voltage 120-277 VAC 60HZ Input Current.3339A Max @ 120V; 0..18A Max @ 277V Input Power 40W Power Factor PF 0.99 Luminance
More informationCTI nm mg. Test Report. Report No.: EED35H l Page 1 of 15. EiKO Global, LLC W 84th St, Shawnee, KS
CTI nmmg CENTRE TESTING INTERNATIONAL Test Report NVLAP LAB CODE 200889-0 Report No.: EED35H000306- l Page 1 of 15 Customer Address EiKO Global, LLC 23220 W 84th St, Shawnee, KS 66227 Description of the
More informationReport No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary
Test Summary Model MT8N28 Luminous Efficacy (Lumens /Watt) 101.5 Total Luminous Flux (Lumens) 1860.0 Power (Watts)/2 18.32 Power Factor 0.9972 CCT (K) 3948 CRI 82.9 Stabilization Time (Light & Power) 60
More information57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG
57-100W-XXK-WPH12-SG 57-100W-40K-WPH12-SG 57-100W-57K-WPH12-SG Eternal Shine Technology Co.,Ltd. EST 57-100W-XXK-WPH12-SG 1.2 Test Specifications: Date of Receipt Date of Test Test item Reference Standard
More informationReport No.: HZ d
Test Summary Model LLT-4-T8-15W-DBA-C-50K Luminous Efficacy (Lumens /Watt) 112.3 Total Luminous Flux (Lumens) 1953.0 Power (Watts)/2 17.39 Power Factor 0.9974 CCT (K) 5140 CRI 82.9 Stabilization Time (Light
More informationReport No.: HZ c
Test Summary Model L13T8DF450-CG4 Luminous Efficacy (Lumens /Watt) 121.4 Total Luminous Flux (Lumens) 2038.0 Power (Watts)/2 16.79 Power Factor 0.9957 CCT (K) 4912 CRI 81.5 Stabilization Time (Light &
More informationEternal Shine Technology Co.,Ltd. EST
Eternal Shine Technology Co.,Ltd. EST NO.7 Flood, Bldg A,Shenfubao Industry Park, Bonded area, Futian District,Shenzhen, China 57-40W-XXK-WPH06-SG 57-40W-40K-WPH06-SG 57-40W-57K-WPH06-SG Eternal Shine
More informationLM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D
Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report For EIKO GLOBAL, LLC 23220 W 84th Street, Shawnee, KS 66227 T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D Laboratory: Leading Testing Laboratories
More informationNVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006
LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP50AUT550BPCMA BLP50AUT530BPCMA Representative (Tested)
More informationLM Test. for LED. Cabinet
LM-79-08 Test Report for ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, ZhuhaiCity, Guangdong Province, P.R. China 5190855 LED Cabinet Light Model: 535021## #(##=11-30)
More informationNVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire
LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA ) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Full-Cutoff Wall-mounted Area Luminaire Model
More informationL Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR
Quality Assured NVLAP LAB CODE 200960-0 L 1-79-08 Test Report for EIKO GLOBAL, LLC 23220 W 84th Street, Shawnee, KS 66227 LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR Laboratory: Leading Testing Laboratories
More informationNVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires
LM-79-08 Test Report For Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): Remark: The suffix X can be A, B, B2, C, C2, D, D2, E, E2, F, F2 representing different mounting bracket; Y
More informationNVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ
LM-79-08 Test Report For Maxlite Inc (Brand Name: ) 12 York Avenue, West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO84040W Test & Report By: Johnson Sun Engineer: Johnson Sun Date: Jun.10,2015
More information71332 LED Dusk To Dawn (Area Light)
71332 LED Dusk To Dawn (Area Light) 48 QPL ID # PK6ZRDD6 dusk-to-dawn photocell LM-79-08 Test Report For Morris Products Inc. (Brand Name: Morris) 53 Carey Road Queensbury, NY 12804 Outdoor Wall-Mounted
More informationLM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA
LM-79-08 Test Report For FALKOR INDUSTRY INC (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA 90201 USA High-bay Luminaires for Commercial and Industrial Buildings Model name(s): FI-HB-2FT-110W
More informationLM Test Report
LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No. 1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R.China, 519085 LED Linear Ambient Light Model Name(s):
More informationDRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.
IESNA SUSTAINING MEMBER Test report of IES LM-79-08 Ref. No.: LCGP14100013 Date of issue Oct 18, 2014 Version 1.0 Total pages: 11 Approved Method: Electrical and Photometric Measurements of Solid-State
More informationNVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)
LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,
More informationNVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ
LM-79-08 Test Report For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO61840W Representative (Tested) Model: RRECO61840W Test & Report By: Johnson
More informationNVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W
LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-50W Representative (Tested) Model: WML-50NW WML-50CW Model Different: All construction and rating
More informationNVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W
LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWA-50W Remark: X=CCT(3=3000K,4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits to indicate
More informationLM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA
LM-79-08 Test Report For FALKOR INDUSTRY INC (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA 90201 USA 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): FI-CPL1212*603-50W-D
More informationNVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires
LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-30W Remark: X=CCT(4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits
More informationNVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS
LM-79-08 Test Report For EIKO GLOBAL, LLC 23220 W 84th St., Shawnee, KS 66227. Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): WPT1-55/8XX-BZ-U Remark:The letter X in the model name stands
More informationLM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA
LM-79-08 Test Report For Revolution Lighting Technologies, Inc (Brand Name: ) 2280 Ward Ave. Simi Valley, CA. 93065 Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model name(s): 113XS8-3LT Remark:
More informationNVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101
LM-79-08 Test Report For LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101 Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): LED2-ARD-70W-30, LED2-ARD-70WD-30
More informationNVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101
LM-79-08 Test Report For LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101 Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): LED2-ARD-100W-30, LED2-ARD-100WD-30
More informationLM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen
LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen High-bay Luminaires for Commercial and Industrial Buildings
More informationNVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013
LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013 High-bay Luminaires for Commercial and Industrial Buildings Model name(s): LED-9300-XXK Remark:
More informationLM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model
More informationNVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730
LM-79-08 Test Report For ATG ELECTRONICS CORP (Brand Name: N/A) 10700 7th Street Rancho Cucamonga, CA 91730 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): FPEL24-40W-ZZ
More informationNVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006
LM-79-08 Test Report For Maxlite INC (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): MLFP24EP50XX Remark: The
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Full-Cutoff Wall-mounted Area Luminaire Model name(s): HC-WPC-40 Representative
More informationNVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)
LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Fuel Pump Canopy Luminaires Model name(s): TLCLB80XYYZZ
More informationLM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires
More informationREVOLUTION LIGHTING TECHNOLOGIES INC
LM-79-08 Test Report For REVOLUTION LIGHTING TECHNOLOGIES INC (Brand Name: Revolution Lighting Technologies) 2280 Ward Ave, Simi Valley, CA 93065 Integrated Retrofit Kits for 2x4 Luminaires Model name(s):
More informationLM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454
LM-79-08 Test Report For KEYSTONE TECHNOLOGIES LLC (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454 1x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): KT-PLED40-14-830-VDIM
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s):
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s):
More informationApproved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products
IESNA SUSTAINING MEMBER Ref. No.: LCZP15060026 Date of issue June 5, 2015 Version 1.0 Total pages: 11 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State
More informationNVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires
LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWP2-80W Remark:The letter X in the model name stands for CCT as bellow :3=3000K, 4=4000K, 5=5000K; YY stands for mounting
More informationNVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006
LM-79-08 Test Report For MAXLITE,INC (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006 Direct Linear Ambient Luminaires Representative (Tested) Model: LSECO-4NU2050 Model Different: N/A Test & Report
More informationApproved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products
IESNA SUSTAINING MEMBER Date of issue Mar 17, 2015 Version 1.0 Total pages: 11 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Rendered
More informationNVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA
LM-79-08 Test Report For BEYOND LED TECHNOLOGY (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 USA HD FPB Series - High Definition Outdoor Corn Bulb Decorative Luminaires
More informationLM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Low Bay Luminaires for Commercial and Industrial Buildings
More informationLM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model
More informationNVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)
LM-79-08 Test Report For Shenzhen OKT Lighting Co.,LTD (Brand Name: OKT LIGHTING) NO.2076 Jincheng Rd,Shajing Town, Bao'an District, Shenzhen, China. SSL downlight retrofits Model name(s): CE6-40W-XXE
More informationNVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)
LM-79-08 Test Report For Shenzhen OKT Lighting Co.,LTD (Brand Name: OKT LIGHTING) NO.2076 Jincheng Rd,Shajing Town, Bao'an District, Shenzhen, China. SSL downlight retrofits Model name(s): C10-D54W-XXE
More informationLM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model
More informationLM Test Report
LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R. China 519085 LED Ceiling Light Model name(s): 544661##
More informationLM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)
LM-79-08 Test Report For Torshare Ltd. (Brand Name: TORSHARE) 5th Minying Road No.3 Industrial Area Shuitian Shiyan Town Bao'an District,Shenzhen Guangdong 518108 China Direct Linear Ambient Luminaires
More informationCat# LED Wall-PACK
Cat# 71426 LED Wall-PACK OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle
More informationNVLAP LAB CODE Energy Star Test Report. For. Shenzhen OKT Lighting Co.,LTD
Energy Star Test Report For Shenzhen OKT Lighting Co.,LTD (Brand Name:OKT Lighting) NO.2076 Jincheng Rd, Shajing Town, Bao an District,Shenzhen, China SSL downlight retrofits Model name(s):c10-d40w-30e
More informationApproved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products
IESNA SUSTAINING MEMBER Ref. No.: LCGP15040508 Date of issue June 4, 2015 Version 1.0 Total pages: 11 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State
More informationNVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)
LM-79-08 Test Report For SHENZHEN BONLD ELECTRONICS CO.,LTD (Brand Name: BONLD) Bldg2-5, TongFuYu Industrial Park, Aiqun Road, Shiyan Town, Bao an District, Shenzhen, China 1x4 Luminaires for Ambient Lighting
More informationLM Test Report
LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R. China 519085 Wall Pack Model name(s): 533041xx Representative
More informationNVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires
LM-79-08 Test Report For LED Waves, Inc. 4100 1st. Ave. Brooklyn, NY 11232 USA Linear Retrofit Kits for 2x2 Luminaires Model name(s): LWQR2x2-40W Representative (Tested) Model: LWQR2x2-40W-4000K LWQR2x2-40W-5000K
More informationTEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO.
TEST REPORT Job No. 170400516SHA Date: Apr 12,2017 REPORT NO. 170400516SHA-006 TEST OF ONE LED Luminaire MODEL NO. RENDERED TO Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. TEST:
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For IGT LIGHTING INC. 3755 Lincoln St. Suite B, Riverside, CA 92503 Catalog Number IGTTU-2102550G-4T5
More informationCat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69
Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI
More informationLED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.
71352 LED Floodlight RoHS Model: 71352 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output Voltage
More informationNVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)
LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Outdoor Pole/Arm-mounted Area and Roadway Luminaires
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008 Prepared For MaxLite Inc 0 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x46, rraghavan@maxlite.com Test Laboratory & Address:
More informationCat# LED High Bay
Cat# 71402 LED High Bay QPL ID # PPXEAWS8 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: 71402 Input Voltage 100-277VAC 50/60HZ Input Current 1.2A Max Input Power 100 W
More informationRoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90
Cat# 71554 30 Watts 1/2" Knuckle Mount RoHS QPL ID # PHNRJ3EY Model: 71554 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI
More informationApprovedMethod: Electricaland Photometric. Measurements of Solid-State Lighting Products
IESNA SUSTAINING MEMBER Date of issue Mar 28, 2015 Version 1.0 Total pages: 24 Test report of IES LM-79-08 ApprovedMethod: Electricaland Photometric Measurements of Solid-State Lighting Products Rendered
More informationRoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens
Cat# 71552 15 Watt 1/2" Adjustable Knuckle Mount RoHS QPL ID # P4K7RKA9 Model: 71552 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency
More informationCat# 71146A 150W Trunion Mount
Cat# 71146A 150W Trunion Mount RoHS Dimming: 0-10V/PWM/VR QPL ID # PLZOBKAFGDBR Model: 71146A Input Voltage 120-277 VAC 50/60HZ Input Current 1.7A MAX Input Power 150W Power Factor PF 0.90 OVERALL LAMP
More informationRoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS
Cat# 71543 150 Watts Trunion Mount RoHS QPL ID # PF9T16AA Model: 71543 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam
More informationRoHS QPL ID # PLC6V1PABNUJS
Cat# 71836 220 Watts Trunion Mount RoHS QPL ID # PLC6V1PABNUJS OVERALL LAMP PARAMETERS LED DRIVER LED Input Power Power Factor Luminance Luminous Efficiency CRI R9 8 Beam Angle Main Structure Output Voltage
More informationDirect to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0.
LED Wall-PACK/Flood Light Data Sheet Cat# 71152 Direct to wall RoHS Wet Locations Use QPL ID # PLUV5PQHJX3Z Model: 71152 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Input Voltage
More information