Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:

Size: px
Start display at page:

Download "Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:"

Transcription

1 IES LM Test Report Test results reported for: report: Original issue date: LED Lamp 001 LEDC WG 1 January 2012 Prepared for: Testing performed by: LED ABC, Inc. Memorial Highway th Ave. Kirkland, WA Bothell, WA Attn: Mike Michaels mm@ledabc.com (123) Test report prepared by: Test report approved by: Aaron Miller Laboratory Manager, Test and Measurement Services David Rush Director, Test and Measurement Services in full without permission of. Page 1 of 9

2 Report: LEDC WG 1.0 Description of test sample Orb test sample identificaton: LEDC Manufacturer specifications: Manufacturer: LED ABC Voltage (V): 120 Model number: AA Test Current (ma): Part Number: P Wattage (W): 20 Description: LED PAR38 Frequency (Hz): 60 Dimmable: yes Lamp as received Lamp as tested Lamp is measured in a type C goniometer coordinate system (reference IESNA LM 75). Lamp orientation is base up. Detector is 1000 mm from the lamp housing exit aperature. in full without permission of. Page 2 of 9

3 Report: LEDC WG 2.0 Scope of testing Photometric and electrical testing in accordance with IES LM IES Approved Method for the Electrical and Photometric Measurements of Solid State Lighting Products. All measuremets are made using the goniometer spectroradiometer test method. 2.1 Test protocol and data reduction 1. Data is reported for the 360nm to 800nm spectral range with a 1 nm resolution. 3.0 Measurement coordinates for type C spectral goniometer in full without permission of. Page 3 of 9

4 Report: LEDC WG 4.0 Results Integrating Sphere Measurements Test Conditions Test Date: 1 Jan 11 Theta Minimum: 0.0 ± 0.10 Method: goniometer spectroradiometer Theta Maximum: 90.0 ± 0.10 x axis Alignment: 0.0 ± m Theta Step Size: 2.5 ± 0.10 y axis Alignment: 0.0 ± m Phi Minimum: 0.0 ± 0.10 z axis Alignment: 1 ± m Phi Maximum: ± 0.10 Phi Step Size: 22.5 ± 0.10 Optical Measurements Total Integrated Luminous Flux (lm): Chromaticity Coordinates Luminous Efficacy (lm/w): Cx: Correlated Color Temperature CCT (K): 3833 Cy: Color Rendering Index CRI, Ra: 85.3 u: R9: 19 v: Color Purity (%): u': Dominant Wavelength(nm): v': Total Integrated Radiometric Flux (W): Duv: Peak Wavelength (nm): Δu'v': Electrical Measurements Active Power(W): Average Voltage(V): * Apparent Power (W): Average Current (A): Power Factor: 0.77 Frequency (Hz): 60.0 * Set point Thermal Measurements Ambient Temperature ( C): Ambient Humidity (%RH): Sample Temperature ( C): in full without permission of. Page 4 of 9

5 Report: LEDC WG 5.0 Charts 0.07 Spectral Irradiance (θ=0, Φ=0) Spectral Irradiance (W/m 2 *nm) Spectral Illuminance (lm/m 2 /nm) Wavelength (nm) Spectral Illuminance (θ=0, Φ=0) Wavelength (nm) in full without permission of. Page 5 of 9

6 Report: LEDC WG 6.0 Candela Plots Luminous intensity (cd) Luminous Intensity (cd) vs Angle (θ) * θ (degrees) in full without permission of. Page 6 of 9

7 Report: LEDC WG 7.0 Zonal Lumen Summary Zonal Lumen Summary Lumens Per Zone Zone Lumens % Lamp Zone Lumens % Total % 83.60% 92.80% 7.20% % % 34.8% 14.4% 6.6% 4.8% % % % 0.8% 8.0 Illuminance Plots in full without permission of. Page 7 of 9

8 Report: LEDC WG 9.0 Chromaticity Diagram CIE1931 Chromaticity Diagram Plankian Average Center in full without permission of. Page 8 of 9

9 Report: LEDC WG 10.0 Equipment and Reference Standard Description of Lamp Standard Operating Operating current Lamp standard type voltage (VDC) (A) Watts (W) Illuminance (lux) Calibration date Tungsten Halogen /05/2011 Calibration reference Lamp Calibration Chain: Irradiance measurements are traceable to NIST through a 2nd generation lamp of known Irradiance maintained at. The calibration chain is given below. Generation Standard Report/File Number Calibration Date Description 1 s/n F 626 NIST# 844/ /3/2011 NIST 1000W standard lamp Test Instrumentation Item Description /use Manufacturer Model Serial# Calibration due 2 Axis Type C Goniometer CA at use Spectroradiometer SP Jan 12 Power Supply Kikusui PCR500M RB Aug 12 Digital Power Meter Yokogawa WT210 91L Feb Additional Information END OF REPORT in full without permission of. Page 9 of 9

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L600-C30-B25 tel: fax: lm x 0.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L600-C30-B25 tel: fax: lm x 0. Total Integrated Radiant Flux Total Integrated Luminous Flux Luminous Efficacy Peak Wavelength Dominant Wavelength Color Purity CCT CRI Ra Peak Candela Irradiance (W/m 2 *nm) Figure 3 Spectral Illuminance

More information

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L540-C27-B25 tel: fax: lm x 0.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L540-C27-B25 tel: fax: lm x 0. Total Integrated Radiant Flux Total Integrated Luminous Flux Luminous Efficacy Peak Wavelength Dominant Wavelength Color Purity CCT CRI Ra Peak Candela Irradiance (W/m 2 *nm) Figure 3 Spectral Illuminance

More information

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P20-L360-C27-B25 tel: fax: lm x 0.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P20-L360-C27-B25 tel: fax: lm x 0. Total Integrated Radiant Flux Total Integrated Luminous Flux Luminous Efficacy Peak Wavelength Dominant Wavelength Color Purity CCT CRI Ra Peak Candela Irradiance (W/m 2 *nm) Figure 3 Spectral Illuminance

More information

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary Test Summary Sample Tested: ML4LS10SOLBK Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 55.2 552.2 10.01 0.9797 CCT Stabilization Time CRI (K) (Light & Power)

More information

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary Test Summary Sample Tested: LFC41327W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 45.3 544.6 12.02 0.9892 CCT Stabilization Time CRI (K) (Light & Power)

More information

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: L15T8SE450-G Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 125.1 1904.0 15.22 0.9679 CCT (K) CRI Stabilization Time (Light & Power)

More information

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: MLFP24DS4241/SD Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.6 4723.5 43.49 0.9902 CCT (K) CRI Stabilization Time (Light & Power)

More information

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: KT-PLED50-24-850-VDIM /G2 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 117.9 6083.5 51.62 0.9926 CCT (K) CRI Stabilization Time (Light

More information

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG 57-100W-XXK-WPH12-SG 57-100W-40K-WPH12-SG 57-100W-57K-WPH12-SG Eternal Shine Technology Co.,Ltd. EST 57-100W-XXK-WPH12-SG 1.2 Test Specifications: Date of Receipt Date of Test Test item Reference Standard

More information

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 2*4 Retrofit Kits Model: RKT4514U5550DV Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806

More information

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary Test Summary Sample Tested: LFC61541W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 63.3 988.8 15.61 0.9810 CCT Stabilization Time CRI (K) (Light & Power)

More information

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP50AUT550BPCMA BLP50AUT530BPCMA Representative (Tested)

More information

Report No.: HZ d

Report No.: HZ d Test Summary Model LLT-4-T8-15W-DBA-C-50K Luminous Efficacy (Lumens /Watt) 112.3 Total Luminous Flux (Lumens) 1953.0 Power (Watts)/2 17.39 Power Factor 0.9974 CCT (K) 5140 CRI 82.9 Stabilization Time (Light

More information

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923 LM-79-08 Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923 Model(s): Spectrum Lighting SG12SQLED21W35KE1/12SQGW/3.5LA 8 May 2011 This test report presents the results of measurements

More information

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: MLLWP40LED50DS Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 96.2 3353.0 34.85 0.9900 CCT (K) CRI Stabilization Time (Light & Power)

More information

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: FLS50U50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.1 5291.8 48.96 0.9859 CCT (K) CRI Stabilization Time (Light & Power) 5119

More information

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: WPL40AU50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 91.6 3480.4 37.99 0.9907 CCT (K) CRI Stabilization Time (Light & Power) 5257

More information

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: T8FR17/835/DIR/LED Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts)/2 Power Factor 105.4 1761.0 16.70 0.9970 CCT (K) CRI Stabilization Time (Light

More information

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006 LM-79-08 Test Report For Maxlite INC (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): MLFP24EP50XX Remark: The

More information

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 WALLPACK Model: MLSWP30LED50DS Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com

More information

Eternal Shine Technology Co.,Ltd. EST

Eternal Shine Technology Co.,Ltd. EST Eternal Shine Technology Co.,Ltd. EST NO.7 Flood, Bldg A,Shenfubao Industry Park, Bonded area, Futian District,Shenzhen, China 57-40W-XXK-WPH06-SG 57-40W-40K-WPH06-SG 57-40W-57K-WPH06-SG Eternal Shine

More information

Report No.: HZ c

Report No.: HZ c Test Summary Model L13T8DF450-CG4 Luminous Efficacy (Lumens /Watt) 121.4 Total Luminous Flux (Lumens) 2038.0 Power (Watts)/2 16.79 Power Factor 0.9957 CCT (K) 4912 CRI 81.5 Stabilization Time (Light &

More information

LM Test. for LED. Cabinet

LM Test. for LED. Cabinet LM-79-08 Test Report for ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, ZhuhaiCity, Guangdong Province, P.R. China 5190855 LED Cabinet Light Model: 535021## #(##=11-30)

More information

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G101183506 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. Date: June 6, 2013 REPORT NO. 101183506CRT-001 TEST OF ONE LED FLOOD

More information

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: 8PLE26LED35 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 101.5 707.7 6.97 0.9815 CCT (K) CRI Stabilization Time (Light & Power) 3498

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

Report No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary

Report No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary Test Summary Model MT8N28 Luminous Efficacy (Lumens /Watt) 101.5 Total Luminous Flux (Lumens) 1860.0 Power (Watts)/2 18.32 Power Factor 0.9972 CCT (K) 3948 CRI 82.9 Stabilization Time (Light & Power) 60

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540751XX(XX: 01-10) Laboratory:

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540751XX(XX: 61-70) Laboratory:

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540741XX(XX: 01-10) Laboratory:

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED PAR30 Spot light Model: 524142XX(XX:41-50) Laboratory:

More information

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50 LM-79-08 Test Report for Maxlite Inc. 12 York Ave West Caldwell NJ 07006 LED Canopy Model: MLCAN20LED50 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com

More information

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR Quality Assured NVLAP LAB CODE 200960-0 L 1-79-08 Test Report for EIKO GLOBAL, LLC 23220 W 84th Street, Shawnee, KS 66227 LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR Laboratory: Leading Testing Laboratories

More information

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model: LM-79-08 Test Report for Philips (China) Investment Co., Ltd. Building 9, Lane 888, Tianlin Road Shanghai, China InstantFit LEDtube Model: 9290002840 Laboratory: Leading Testing Laboratories NVLAP CODE:

More information

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: LDP2450L35U1 2X4 3500K Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 102.3 5129.5 50.12 0.9883 CCT (K) CRI Stabilization Time (Light

More information

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED Lighting) Rm 1902, Easey Comm Bldg 253-261 Hennessy Rd Wanchai, HONG KONG LED Tube Light Model name(s): HC-T8-8FT-36W-ID(Clear) Representative

More information

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD) LM-79-08 Test Report For SHENZHEN BONLD ELECTRONICS CO.,LTD (Brand Name: BONLD) Bldg2-5, TongFuYu Industrial Park, Aiqun Road, Shiyan Town, Bao an District, Shenzhen, China 1x4 Luminaires for Ambient Lighting

More information

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ LM-79-08 Test Report For Maxlite Inc (Brand Name: ) 12 York Avenue, West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO84040W Test & Report By: Johnson Sun Engineer: Johnson Sun Date: Jun.10,2015

More information

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report For EIKO GLOBAL, LLC 23220 W 84th Street, Shawnee, KS 66227 T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D Laboratory: Leading Testing Laboratories

More information

71332 LED Dusk To Dawn (Area Light)

71332 LED Dusk To Dawn (Area Light) 71332 LED Dusk To Dawn (Area Light) 48 QPL ID # PK6ZRDD6 dusk-to-dawn photocell LM-79-08 Test Report For Morris Products Inc. (Brand Name: Morris) 53 Carey Road Queensbury, NY 12804 Outdoor Wall-Mounted

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB01271 PAGE: 1 OF 5 LUMINAIRE: LUMINAIRE: FABRICATED WHITE PAINTED METAL HOUSING, 4 WHITE CIRCUIT BOARDS EACH WITH 120 LEDS, FROSTED HOLOGRAPHIC PLASTIC LENS. LENS FROSTED SIDE UP. LAMPS:

More information

Cat# LED Wall-PACK

Cat# LED Wall-PACK Cat# 71426 LED Wall-PACK OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle

More information

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

LED Floodlight. RoHS. Model: inner box: L 17 X W 12.5 X H 9.33 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W. 71352 LED Floodlight RoHS Model: 71352 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output Voltage

More information

TEST REPORT. Job No SHA Date: February 19, 2017 REPORT NO SHA-003

TEST REPORT. Job No SHA Date: February 19, 2017 REPORT NO SHA-003 TEST REPORT Job No. 170101691SHA Date: February 19, 2017 REPORT NO. 170101691SHA-003 TEST OF Outdoor Full-Cutoff Wall-mounted Area Luminaires MODEL NO. WP-ADS30U-40B / WP-ADS30U-40B-PC RENDERED TO Maxlite,

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ LM-79-08 Test Report For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO61840W Representative (Tested) Model: RRECO61840W Test & Report By: Johnson

More information

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A LM-79-08 Test Report for Elec-Tech International Co., Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China BR40 LAMP Model: 525021XX(XX:01-10), WBR40L27S2A Laboratory:

More information

IESNA LM Test Report

IESNA LM Test Report IESNA LM79-2008 Test Report Photometric testing and evaluation in accordance with LM79-2008 Report prepared for: R. STAHL Schaltgeräte GmbH Nordstraße 10 99427 Weimar / Germany Report number: LM79-200330-9173

More information

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report for EiKO Global, LLC 23220 W. 84th St. Shawnee, KS 66227 25W Floodlight Model: FLM-2C-N-U Laboratory: Leading Testing Laboratories NVLAP CODE:

More information

TEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO.

TEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO. TEST REPORT Job No. 170400516SHA Date: Apr 12,2017 REPORT NO. 170400516SHA-006 TEST OF ONE LED Luminaire MODEL NO. RENDERED TO Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. TEST:

More information

REVOLUTION LIGHTING TECHNOLOGIES INC

REVOLUTION LIGHTING TECHNOLOGIES INC LM-79-08 Test Report For REVOLUTION LIGHTING TECHNOLOGIES INC (Brand Name: Revolution Lighting Technologies) 2280 Ward Ave, Simi Valley, CA 93065 Integrated Retrofit Kits for 2x4 Luminaires Model name(s):

More information

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA 93063

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA 93063 Report No: L121500506 Date: 12/9/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L121500506 Report Prepared For: Revolution Lighting Technologies

More information

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101 LM-79-08 Test Report For LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101 Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): LED2-ARD-70W-30, LED2-ARD-70WD-30

More information

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101 LM-79-08 Test Report For LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101 Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): LED2-ARD-100W-30, LED2-ARD-100WD-30

More information

IESNA LM Test Report

IESNA LM Test Report IESNA LM79-2008 Test Report Photometric testing and evaluation in accordance with LM79-2008 Report prepared for: R. STAHL Schaltgeräte GmbH Nordstraße 10 99427 Weimar / Germany Report number: LM79201510-D

More information

1120 Goffle Road Hawthorne NJ Photometric/Colorimetric/Electrical Test

1120 Goffle Road Hawthorne NJ Photometric/Colorimetric/Electrical Test Report No: L111708109 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L111708109 Issue Date: 1/10/2018 Report Prepared For: CAST Lighting LLC. 1120 Goffle Road Hawthorne NJ 07506-2024

More information

Calibration Due Date Chroma Programmable AC Source 61604

Calibration Due Date Chroma Programmable AC Source 61604 Test #: L04130402 Date: 5/2/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L04130402 TVL4000 CW Report Prepared For: ELATION

More information

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA LM-79-08 Test Report For FALKOR INDUSTRY INC (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA 90201 USA 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): FI-CPL1212*603-50W-D

More information

Revolution Lighting 4139 Guardian St. Simi Valley CA 93063

Revolution Lighting 4139 Guardian St. Simi Valley CA 93063 Report No: L121605937R02 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121605937R02 Issue Date: 2/17/2017 Report Prepared For: Revolution Lighting 4139 Guardian St. Simi Valley

More information

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 100402-0.. REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 Project No. G101555841 Date: March 21, 2014 REPORT NO. 101555841CRT-001 TEST OF ONE LED

More information

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS LM-79-08 Test Report For EIKO GLOBAL, LLC 23220 W 84th St., Shawnee, KS 66227. Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): WPT1-55/8XX-BZ-U Remark:The letter X in the model name stands

More information

Client submitted the sample. Catalog number is LRH240U. Received in working and undamaged condition. No modifications were necessary.

Client submitted the sample. Catalog number is LRH240U. Received in working and undamaged condition. No modifications were necessary. Report No: L031500702 Date: 3/13/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L031500702 Report Prepared For: EiKO Global, LLC 23220 W.

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L051603301 Date: 5/19/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L051603301 Report Prepared For: Colt LED Model Number: D12X6-GEN3-55W

More information

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model

More information

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02 Report No: L041608503 Date: 4/29/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041608503 Report Prepared For: GM LIGHTING 9830 W 190th St,

More information

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model

More information

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen High-bay Luminaires for Commercial and Industrial Buildings

More information

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA LM-79-08 Test Report For FALKOR INDUSTRY INC (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA 90201 USA High-bay Luminaires for Commercial and Industrial Buildings Model name(s): FI-HB-2FT-110W

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013 LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013 High-bay Luminaires for Commercial and Industrial Buildings Model name(s): LED-9300-XXK Remark:

More information

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA LM-79-08 Test Report For Revolution Lighting Technologies, Inc (Brand Name: ) 2280 Ward Ave. Simi Valley, CA. 93065 Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model name(s): 113XS8-3LT Remark:

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB03176 PAGE: 1 OF 9 LUMINAIRE: CAST WHITE PAINTED FINNED METAL HEAT SINK,SHEETMETAL JUNCTION BOX AFFIXED TO TOP OF HEATSINK, 1 CIRCUIT BOARD WITH 10 LEDS. LAMPS: TEN WHITE MULTI-CHIP LIGHT

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L121404501R02 Date: 12/22/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L121404501R02 Report Prepared For: Texas Fluorescents

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Test #: L12125907R02 Date: 1/14/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L12125907R02 LR24-5000L-35K Report Prepared

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB01842 PAGE: 1 OF 6 CATALOG NUMBER: SWISH2X2-29YN/D10 LUMINAIRE: WHITE PAINTED SHEET METAL HOUSING, 2 WHITE CIRCUIT BOARDS EACH WITH 60 LEDS, FROSTED POLYCARBONATE LENS IN THE CENTER,

More information

Equipment Used Model No Stock No Calibration Due Date

Equipment Used Model No Stock No Calibration Due Date Report No: L091401801 Date: 9/16/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L091401801 Report Prepared For: Olympia Lighting, inc. 50

More information

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454 LM-79-08 Test Report For KEYSTONE TECHNOLOGIES LLC (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454 1x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): KT-PLED40-14-830-VDIM

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB03145 PAGE: 1 OF 9 LUMINAIRE: EXTRUDED METAL HOUSING WITH HEAT SINK FINS, TWO WHITE CIRCUIT BOARD WITH THREE HUNDRED LEDS ON EACH BOARD, METAL REFLECTOR WITH SPECULAR FINISH, FLAT TRANSLUCENT

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB03414 PAGE: 1 OF 9 LUMINAIRE: EXTRUDED METAL HOUSING WITH HEAT SINK FINS, TWO WHITE CIRCUIT BOARD WITH THREE HUNDRED LEDS ON EACH BOARD, METAL REFLECTOR WITH SPECULAR FINISH, FLAT TRANSLUCENT

More information

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-50W Representative (Tested) Model: WML-50NW WML-50CW Model Different: All construction and rating

More information

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires LM-79-08 Test Report For Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): Remark: The suffix X can be A, B, B2, C, C2, D, D2, E, E2, F, F2 representing different mounting bracket; Y

More information

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWP2-80W Remark:The letter X in the model name stands for CCT as bellow :3=3000K, 4=4000K, 5=5000K; YY stands for mounting

More information

IESNA LM-79: Measurement and Test Report for. Green Creative. Xinsen Science &Trade Park, Unit 327,839An'Yuan Road, Shanghai, China

IESNA LM-79: Measurement and Test Report for. Green Creative. Xinsen Science &Trade Park, Unit 327,839An'Yuan Road, Shanghai, China IESNA LM-79: 2008 Measurement and Test Report for Green Creative Xinsen Science &Trade Park, Unit 327,839An'Yuan Road, Shanghai, China I I l i \ II I: Feb 06, 2013 Product Name: LED Lamp Jl II Model No:

More information

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWA-50W Remark: X=CCT(3=3000K,4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits to indicate

More information

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Low Bay Luminaires for Commercial and Industrial Buildings

More information

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA ) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Full-Cutoff Wall-mounted Area Luminaire Model

More information

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires LM-79-08 Test Report For LED Waves, Inc. 4100 1st. Ave. Brooklyn, NY 11232 USA Linear Retrofit Kits for 2x2 Luminaires Model name(s): LWQR2x2-40W Representative (Tested) Model: LWQR2x2-40W-4000K LWQR2x2-40W-5000K

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L061507801 Date: 7/20/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L061507801 Report Prepared For: Beachside Lighting 905 Kalanianaole

More information

Number Eight Lighting Company MPT2-HI-R-6-BK/15/DIM1-M-1000

Number Eight Lighting Company MPT2-HI-R-6-BK/15/DIM1-M-1000 Report No: L121706545 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706545 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,

More information

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA LM-79-08 Test Report For BEYOND LED TECHNOLOGY (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 USA HD FPB Series - High Definition Outdoor Corn Bulb Decorative Luminaires

More information

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-30W Remark: X=CCT(4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L071600301 Date: 7/6/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071600301 Report Prepared For: Revolution Lighting Technologies

More information

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02 Report No: L071600303 Date: 7/6/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071600303 Report Prepared For: Revolution Lighting Technologies

More information

Report No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample

Report No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample Test Summary Sample Tested: AR-MAL100UT3-40X Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 131.6 12593.0 95.69 0.9967 CCT (K) CRI Stabilization Time (Light &

More information

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE) LM-79-08 Test Report For Torshare Ltd. (Brand Name: TORSHARE) 5th Minying Road No.3 Industrial Area Shuitian Shiyan Town Bao'an District,Shenzhen Guangdong 518108 China Direct Linear Ambient Luminaires

More information

Photometric Indoor Test Report

Photometric Indoor Test Report Photometric Indoor Test Report Relevant Standards LM-79-28 Prepared For Sea Gull Lighting Andre Duljas 31 W. Washington Street Riverside, NJ 875 Catalog Number 96118S-32 LTL Test Number 2191 Test Date

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L051503011 Date: 5/21/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L051503011 Report Prepared For: USTE, dba Vista Professional

More information

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model

More information

IESNA LM79: 2008 Photometric Test Report

IESNA LM79: 2008 Photometric Test Report IESNA LM79: 2008 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-2008 Report Prepared For Alex Truong Product Manager MaxLite Description of Sample: 100W LED AREA LIGHT

More information

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730 LM-79-08 Test Report For ATG ELECTRONICS CORP (Brand Name: N/A) 10700 7th Street Rancho Cucamonga, CA 91730 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): FPEL24-40W-ZZ

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE