IESNA LM79: 2008 Photometric Test Report
|
|
- Sibyl Harrell
- 5 years ago
- Views:
Transcription
1 IESNA LM79: 2008 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM Report Prepared For Alex Truong Product Manager MaxLite Description of Sample: 100W LED AREA LIGHT RETROFIT LAMP 5000K E39 Model AR100LED50. The Sample (s) was (were) tested in accordance with the following applied standards/regulations: IESNA LM79: 2008 Approved for Electrical and Photometric Measurements of Solid-State Lighting Products. ANSI NEMA C78.377: 2011 Specification of the Chromaticity of Solid State Lighting Products. ANSI C82.77:2002 Harmonic Emissions Limits Related Power Quality Requirement for Light Equipment. CITL Test Number: CITL Sample Arrival Date: 10/17/2016 Date of Test: Report Issue Date: Report Prepared By: Report Approved By: Johnathan Taddei Lab Assistant Jun Xiang Lab Manager P a g e 1 7
2 Sample Number: 1839 Manufacturer: MaxLite Notes: Tested in intended orientation Equipment Used: Description Model # Serial # Calibration Date Calibration Due Date Goniophotometer GO-R5000 G116930CS /3/2016 2/7/2017 EVERFINE AC POWER SUPPLY DPS1060 G A YOKOGAWA POWER ANALYZER WT310 C2QJ22012V 10/22/ /31/2017 DC POWER SUPPLY WY12010 G115909TM EVERFINE AC POWER SUPPLY DSP1005 G119890CJ DC POWER SUPPLY WY305 G115986TA INTERGRATING SPHERE 2 METER CITL /7/ /7/2016 YOKOGAWA POWER ANALYZER WT310 C2QJ22011V 11/25/ /25/2016 FLUKE DIGITAL THERMOMETER 51II WS 3/4/2016 3/31/2017 TEMPERATURE AND HUMIDITY LOGGER UX /22/2016 3/31/2017 LM-79 Test Summary: Manufacture: Fixture Model Number: Driver Model Number: LED Model Number: MaxLite AR100LED50 No Driver Model Number Information Available No LED Model Number Information Available P a g e 2 7
3 Electrical Measurement: Input Voltage: 120VAC 277VAC Input Current: A A Input Frequency: 60 HZ 60 Hz Input Power: 99.55W 98.1W Power Factor: Total Harmonic Distortion: ATHD ATHD Lumen Output: Lumens: 11833Lm Efficacy: 119Lm/W Color Rendering Index *(CRI) Ra: 84.1 R₉: 16.0 Correlated Color Temperature (K): 5021K Chromaticity Coordinate x: Chromaticity Coordinate y: Ambient Temperature ( C): 25 C Stabilization Time (Hours): 60 Mins Total Operation Time (Hours): 3 Hrs. u/u : V : Duv: Center Beam Candle Power (cd): Max Candela(cd): 4,278.7 at Horizontal: 105, Vertical: 2.5 Spacing Criteria (0-180) 1.30 Spacing Criteria (90-270) 1.32 Zonal Lumens in the 0-60 Zone 9,760.7Lm 82.5% Zonal Lumens in the Zone 2,057.1Lm 17.4% Zonal Lumens in the 0-90 Zone 11,817.7Lm 99.9% Zonal Lumens in the Zone 2.4Lm 0.0% Zonal Lumens in the Zone 12.2Lm 0.1% P a g e 3 7
4 Test Methods: Photometric Measurements Goniophotometer: An Everfine Type C Rotating Mirror Goniophotometer was used to measure candelas (intensity) at each angle of distribution as defined by IESNA for the appropriate fixture type. Ambient temperature is set to 25 C and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25 C throughout the testing process and the sample is stabilized for at least 60 minutes and longer as necessary for the sample to achieve stabilization. Electrical measurements are measure using the listed equipment. Spectral Measurements Integrating Sphere A sensing Spectrometer HASS-2000, in conjunction with Everfine 2 meter integrating sphere was used to measure chromaticity coordinates, correlated color temperature (CCT) and the color rendering index (CRI) for each sample. Test Geometry Configuration 4 π. Ambient temperature is set to 25 C and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25 C throughout the testing process and the sample is stabilized for at least 30 min and longer if necessary for the sample to achieve stabilization Electrical measurements are measured using the listed equipment. LUMINAIRE PHOTOMETRIC TEST REPORT: P a g e 4 7
5 ZONAL FLUX DIAGRAM: P a g e 5 7
6 ISOCANDELA DIAGRAM: ISOLUX DIAGRAM: P a g e 6 7
7 AAI DIAGRAM: ***End of Report*** P a g e 7 7
IESNA LM79: 2008 Photometric Test Report
IESNA LM79: 2008 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-2008 Report Prepared For Alex Truong Product Manager MaxLite Description of Sample: 25W 4-FT DIRECTFIT
More informationIESNA LM79: 2008 Photometric Test Report
IESNA LM79: 2008 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-2008 Report Prepared For Brendan Drew Product Manager MaxLite Description of Sample: 36inch80CRI 2700K
More informationIESNA LM79: 2008 Photometric Test Report
IESNA LM79: 2008 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-2008 Report Prepared For Alex Truong Product Manager MaxLite Description of Sample: 11W LED OMNI A19
More informationIESNA LM79: 2008 Photometric Test Report
IESNA LM79: 2008 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-2008 Report Prepared For Ramesh Raghavan Product Manager MaxLite Description of Sample: 5-6" Downlight
More informationIESNA LM79: 2008 Photometric Test Report
IESNA LM79: 2008 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-2008 Report Prepared For Christian Groom Management Associate MaxLite Description of Sample: CPL Slim
More informationIESNA LM79: 2008 Photometric Test Report
IESNA LM79: 2008 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-2008 Report Prepared For Eric Clohosey Product Manager MaxLite Description of Sample: MPulse SM VC Series
More information1120 Goffle Road Hawthorne NJ Photometric/Colorimetric/Electrical Test
Report No: L111708109 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L111708109 Issue Date: 1/10/2018 Report Prepared For: CAST Lighting LLC. 1120 Goffle Road Hawthorne NJ 07506-2024
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L051503011 Date: 5/21/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L051503011 Report Prepared For: USTE, dba Vista Professional
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L061507801 Date: 7/20/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L061507801 Report Prepared For: Beachside Lighting 905 Kalanianaole
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L091502201 Date: 9/10/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L091502201 Report Prepared For: Vista Professional Outdoor
More informationVista Professional Outdoor Lighting 1625 Surveyor Ave., Simi Valley CA Fixture is tested with no special conditions.
Report No: L021606506 Date: 3/4/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L021606506 Report Prepared For: Vista Professional Outdoor
More informationReport No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: KT-PLED50-24-850-VDIM /G2 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 117.9 6083.5 51.62 0.9926 CCT (K) CRI Stabilization Time (Light
More information57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG
57-100W-XXK-WPH12-SG 57-100W-40K-WPH12-SG 57-100W-57K-WPH12-SG Eternal Shine Technology Co.,Ltd. EST 57-100W-XXK-WPH12-SG 1.2 Test Specifications: Date of Receipt Date of Test Test item Reference Standard
More informationReport No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: L15T8SE450-G Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 125.1 1904.0 15.22 0.9679 CCT (K) CRI Stabilization Time (Light & Power)
More informationCast Lighting 1120-A Goffle Rd., Hawthorne, NJ., Fixture is tested with no special conditions.
Report No: L111407109 Date: 12/9/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111407109 Report Prepared For: Cast Lighting 1120-A Goffle
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L10131601 Date: 10/10/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L10131601 ELED Strip TW BOTH A Report Prepared
More informationTEST REPORT. Job No SHA Date: February 19, 2017 REPORT NO SHA-003
TEST REPORT Job No. 170101691SHA Date: February 19, 2017 REPORT NO. 170101691SHA-003 TEST OF Outdoor Full-Cutoff Wall-mounted Area Luminaires MODEL NO. WP-ADS30U-40B / WP-ADS30U-40B-PC RENDERED TO Maxlite,
More informationCast Lighting 1120-A Goffle Rd., Hawthorne, NJ., 07506
Report No: L111407302 Date: 1/15/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111407302 Report Prepared For: Cast Lighting 1120-A Goffle
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L051603301 Date: 5/19/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L051603301 Report Prepared For: Colt LED Model Number: D12X6-GEN3-55W
More informationCast Lighting 1120-A Goffle Rd., Hawthorne, NJ., Fixture is tested with no special conditions.
Report No: L111407108 Date: 12/9/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111407108 Report Prepared For: Cast Lighting 1120-A Goffle
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ.
Test #: L08124408 Date:08/31/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L08124408 RR61430W Report Prepared For: MAXLITE
More informationU.S.T.E. dba Vista Professional Outdoor Lighting 1625 Surveyor Ave. Simi Valley CA Fixture is tested with no special conditions.
Report No: L081407404 Date: 9/3/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L081407404 Report Prepared For: U.S.T.E. dba Vista Professional
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Old Conejo Road #118, Newbury Park, CA, 91320
Report No: L061605303 Date: 6/16/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L061605303 HK Lighting Group
More informationReport No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: 8PLE26LED35 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 101.5 707.7 6.97 0.9815 CCT (K) CRI Stabilization Time (Light & Power) 3498
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Old Conejo Road #118, Newbury Park, CA, 91320
Report No: L061605301 Date: 6/16/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L061605301 HK Lighting Group
More informationNumber Eight Lighting Company MPT2-HI-R-6-BK/15/DIM1-M-1000
Report No: L121706545 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706545 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,
More informationEquipment Used Model No Stock No Calibration Due Date
Report No: L091401801 Date: 9/16/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L091401801 Report Prepared For: Olympia Lighting, inc. 50
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Kalanianaole Hwy # 29A Kailua, HI.
Report No: L061606303 Date: 8/1/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L061606303 Beachside Lighting
More informationMoon Visions Lighting 780 S. Floyd Rd., Suite 2B, Richardson, TX Electrical and Photometric tests as required by the IESNA test standards.
Test #: L061402510 Date: 6/16/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L061402510 LED MV120V R30 14W 5K FL Report Prepared
More informationEternal Shine Technology Co.,Ltd. EST
Eternal Shine Technology Co.,Ltd. EST NO.7 Flood, Bldg A,Shenfubao Industry Park, Bonded area, Futian District,Shenzhen, China 57-40W-XXK-WPH06-SG 57-40W-40K-WPH06-SG 57-40W-57K-WPH06-SG Eternal Shine
More informationRevolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA 93063
Report No: L121500506 Date: 12/9/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L121500506 Report Prepared For: Revolution Lighting Technologies
More informationReport No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: MLFP24DS4241/SD Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.6 4723.5 43.49 0.9902 CCT (K) CRI Stabilization Time (Light & Power)
More informationLM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV
LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 2*4 Retrofit Kits Model: RKT4514U5550DV Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L071600301 Date: 7/6/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071600301 Report Prepared For: Revolution Lighting Technologies
More informationModel No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02
Report No: L041608503 Date: 4/29/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041608503 Report Prepared For: GM LIGHTING 9830 W 190th St,
More informationModel No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02
Report No: L071600303 Date: 7/6/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071600303 Report Prepared For: Revolution Lighting Technologies
More informationCalibration Due Date Chroma Programmable AC Source 61604
Test #: L04130402 Date: 5/2/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L04130402 TVL4000 CW Report Prepared For: ELATION
More informationClient submitted the sample. Catalog number is LRH240U. Received in working and undamaged condition. No modifications were necessary.
Report No: L031500702 Date: 3/13/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L031500702 Report Prepared For: EiKO Global, LLC 23220 W.
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L113141 Date: 1/8/213 8165 E Kaiser Blvd. Anaheim, CA 9288 p. 714.282.227 f. 714.676.5558 NVLAP LAB CODE 2927 Test Report: L113141 Model Number: LR22-33L-35K Report Prepared For: Raffino Inc. Test:
More informationReport No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: FLS50U50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.1 5291.8 48.96 0.9859 CCT (K) CRI Stabilization Time (Light & Power) 5119
More informationReport No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: MLLWP40LED50DS Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 96.2 3353.0 34.85 0.9900 CCT (K) CRI Stabilization Time (Light & Power)
More informationReport No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: WPL40AU50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 91.6 3480.4 37.99 0.9907 CCT (K) CRI Stabilization Time (Light & Power) 5257
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L041609601 Date: 5/5/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041609601 Report Prepared For: GM LIGHTING 9830 W 190th St,
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L121404501R02 Date: 12/22/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L121404501R02 Report Prepared For: Texas Fluorescents
More informationBARTCO Lighting 5761 Research Drive, Huntington Beach, CA 92649
Report No: L101601204 Date: 10/18/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L101601204 Report Prepared For: BARTCO Lighting 5761 Research
More informationNVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006
LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP50AUT550BPCMA BLP50AUT530BPCMA Representative (Tested)
More informationReport No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: LDP2450L35U1 2X4 3500K Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 102.3 5129.5 50.12 0.9883 CCT (K) CRI Stabilization Time (Light
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L1212321 Date: 12/1/212 8165 E Kaiser Blvd. Anaheim, CA 9288 p. 714.282.227 f. 714.676.5558 NVLAP LAB CODE 2927 Test Report: L1212321 Model Number: LT24-4L-35K Report Prepared For: Raffino Inc.
More information(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary
Test Summary Sample Tested: LFC41327W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 45.3 544.6 12.02 0.9892 CCT Stabilization Time CRI (K) (Light & Power)
More informationRevolution Lighting 4139 Guardian St. Simi Valley CA 93063
Report No: L121605937R02 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121605937R02 Issue Date: 2/17/2017 Report Prepared For: Revolution Lighting 4139 Guardian St. Simi Valley
More informationTEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO.
TEST REPORT Job No. 170400516SHA Date: Apr 12,2017 REPORT NO. 170400516SHA-006 TEST OF ONE LED Luminaire MODEL NO. RENDERED TO Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. TEST:
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE Jersey Blvd. Rancho Cucamonga, CA 91730
Test #: L06122603 Date: 6/15/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L06122603 MLRT24D5535 Report Prepared For: MAXLITE
More informationLM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS
LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 WALLPACK Model: MLSWP30LED50DS Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com
More informationRevolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.
Report No: L111503505 Date: 11/18/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111503505 Report Prepared For: Revolution Lighting Technologies
More informationRevolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.
Report No: L111503504 Date: 11/18/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111503504 Report Prepared For: Revolution Lighting Technologies
More informationLM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:
LM-79-08 Test Report for Philips (China) Investment Co., Ltd. Building 9, Lane 888, Tianlin Road Shanghai, China InstantFit LEDtube Model: 9290002840 Laboratory: Leading Testing Laboratories NVLAP CODE:
More informationBeachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI
Report No: L061606106 Date: 7/19/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L061606106 Report Prepared For: Beachside Lighting 905 Kalanianaole
More informationUSTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063
Report No: L091706906 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L091706906 Issue Date: 10/9/2017 Report Prepared For: USTE, dba Vista Professional Outdoor Lighting 1625 Surveyor
More informationLM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA
LM-79-08 Test Report For FALKOR INDUSTRY INC (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA 90201 USA High-bay Luminaires for Commercial and Industrial Buildings Model name(s): FI-HB-2FT-110W
More information(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary
Test Summary Sample Tested: LFC61541W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 63.3 988.8 15.61 0.9810 CCT Stabilization Time CRI (K) (Light & Power)
More informationReport No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: T8FR17/835/DIR/LED Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts)/2 Power Factor 105.4 1761.0 16.70 0.9970 CCT (K) CRI Stabilization Time (Light
More informationUSTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063
Report No: L091706904 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L091706904 Issue Date: 10/9/2017 Report Prepared For: USTE, dba Vista Professional Outdoor Lighting 1625 Surveyor
More informationLM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U
Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report for EiKO Global, LLC 23220 W. 84th St. Shawnee, KS 66227 25W Floodlight Model: FLM-2C-N-U Laboratory: Leading Testing Laboratories NVLAP CODE:
More informationLM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50
LM-79-08 Test Report for Maxlite Inc. 12 York Ave West Caldwell NJ 07006 LED Canopy Model: MLCAN20LED50 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com
More informationLM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen
LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen High-bay Luminaires for Commercial and Industrial Buildings
More informationNVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013
LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013 High-bay Luminaires for Commercial and Industrial Buildings Model name(s): LED-9300-XXK Remark:
More informationNVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ
LM-79-08 Test Report For Maxlite Inc (Brand Name: ) 12 York Avenue, West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO84040W Test & Report By: Johnson Sun Engineer: Johnson Sun Date: Jun.10,2015
More informationCast Lighting 1120-A Goffle Rd., Hawthorne, NJ., 07506
Report No: L111407206 Date: 12/11/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111407206 Report Prepared For: Cast Lighting 1120-A Goffle
More informationREVOLUTION LIGHTING TECHNOLOGIES INC
LM-79-08 Test Report For REVOLUTION LIGHTING TECHNOLOGIES INC (Brand Name: Revolution Lighting Technologies) 2280 Ward Ave, Simi Valley, CA 93065 Integrated Retrofit Kits for 2x4 Luminaires Model name(s):
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Full-Cutoff Wall-mounted Area Luminaire Model name(s): HC-WPC-40 Representative
More informationLM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454
LM-79-08 Test Report For KEYSTONE TECHNOLOGIES LLC (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454 1x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): KT-PLED40-14-830-VDIM
More informationNVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)
LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,
More informationNVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W
LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-50W Representative (Tested) Model: WML-50NW WML-50CW Model Different: All construction and rating
More informationNVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires
LM-79-08 Test Report For Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): Remark: The suffix X can be A, B, B2, C, C2, D, D2, E, E2, F, F2 representing different mounting bracket; Y
More informationNVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W
LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWA-50W Remark: X=CCT(3=3000K,4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits to indicate
More informationNVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire
LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA ) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Full-Cutoff Wall-mounted Area Luminaire Model
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s):
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s):
More informationLM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA
LM-79-08 Test Report For FALKOR INDUSTRY INC (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA 90201 USA 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): FI-CPL1212*603-50W-D
More informationNVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires
LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-30W Remark: X=CCT(4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits
More information752 North State St, #208, Westerville, OH Photosynthetically active radiation (PAR) & Electrical measurement
Report No: L091800301 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L091800301 Issue Date: 9/10/2018 Report Prepared For: Horticulture Lighting Group 752 North State St, #208,
More informationEiKO Global, LLC W. 84th Street, Shawnee, KS 66227
Report No: L011508802 Date: 2/19/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L011508802 Report Prepared For: EiKO Global, LLC 23220 W.
More informationNVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS
LM-79-08 Test Report For EIKO GLOBAL, LLC 23220 W 84th St., Shawnee, KS 66227. Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): WPT1-55/8XX-BZ-U Remark:The letter X in the model name stands
More informationNVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ
LM-79-08 Test Report For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO61840W Representative (Tested) Model: RRECO61840W Test & Report By: Johnson
More informationNVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA
LM-79-08 Test Report For BEYOND LED TECHNOLOGY (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 USA HD FPB Series - High Definition Outdoor Corn Bulb Decorative Luminaires
More informationLM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Low Bay Luminaires for Commercial and Industrial Buildings
More informationCast Lighting 1120-A Goffle Rd., Hawthorne, NJ 07506
Report No: L071407704 Date: 8/6/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071407704 Report Prepared For: Cast Lighting 1120-A Goffle
More informationNVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730
LM-79-08 Test Report For ATG ELECTRONICS CORP (Brand Name: N/A) 10700 7th Street Rancho Cucamonga, CA 91730 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): FPEL24-40W-ZZ
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Myles Standish Blvd.
Report No: L051604201 Date: 6/1/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L051604201 Lexington Lighting
More informationELATION LIGHTING 6122 S. EASTERN AVE, COMMERCE, CA Electrical and Photometric tests as required by the IESNA test standards.
Test #: L09133804 Date: 10/9/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L09133804 ELED Strip TW CW Report Prepared For:
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Kalanianaole Hwy # 29A Kailua, HI.
Report No: L061507817R01 Date: 8/10/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L061507817R01 Beachside
More informationReport No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample
Test Summary Sample Tested: AR-MAL100UT3-40X Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 131.6 12593.0 95.69 0.9967 CCT (K) CRI Stabilization Time (Light &
More informationLM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)
LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540751XX(XX: 01-10) Laboratory:
More informationLM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)
LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540751XX(XX: 61-70) Laboratory:
More informationLM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)
LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540741XX(XX: 01-10) Laboratory:
More informationNVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires
LM-79-08 Test Report For LED Waves, Inc. 4100 1st. Ave. Brooklyn, NY 11232 USA Linear Retrofit Kits for 2x2 Luminaires Model name(s): LWQR2x2-40W Representative (Tested) Model: LWQR2x2-40W-4000K LWQR2x2-40W-5000K
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L12125907R02 Date: 1/14/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L12125907R02 LR24-5000L-35K Report Prepared
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For IGT LIGHTING INC. 3755 Lincoln St. Suite B, Riverside, CA 92503 Catalog Number IGTTU-2102550G-4T5
More informationNVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires
LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWP2-80W Remark:The letter X in the model name stands for CCT as bellow :3=3000K, 4=4000K, 5=5000K; YY stands for mounting
More informationNVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006
LM-79-08 Test Report For MAXLITE,INC (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006 Direct Linear Ambient Luminaires Representative (Tested) Model: LSECO-4NU2050 Model Different: N/A Test & Report
More information