General Specifications

Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup

Model UP350 Program Controller

Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control

General Specifications

Models UT350/UT320 Digital Indicating Controllers

General Specifications

Model UP351 Program Controller

SHIMADEN DIGITAL INDICATORS

Model UT551 Digital Indicating Controller with Active Color PV Display and Embedded Ethernet User s Manual for Single-loop Control

General Specifications

Model UP750 Program Controller User s Manual for Dual-loop Control

How to Install CAUTION. Panel. 150mm. 150mm. Direction to insert the controller Insert the controller into the opening at the front of the panel.

Model UT750 Digital Indicating Controller User s Manual for Cascade Control

Model UP550 Program Controller User s Manual for Loop Control with PV Switching

SHIMADEN PROGRAM CONTROLLER

Model UT750 Digital Indicating Controller User s Manual for Cascade Primary-loop Control

SHIMADEN DIGITAL INDICATORS

General Specifications

General Specifications

SHIMADEN DIGITAL INDICATOR

DIGITAL PROGRAM CONTROLLER

Model UP550 Program Controller User s Manual for Cascade Primary-loop Control

MICRO-CONTROLLER X (48 48 mm)

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

MICRO-CONTROLLER X (96 96 mm)

indicate that the contacts are available. How to Install CAUTION Panel

DIGITAL INDICATING CONTROLLER

General Specifications

PROCESS & TEMPERATURE CONTROLLERS

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

6/12/24 Dot Printing Model Smart Recorder SRF206/212/224

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

General Specifications

MICRO-CONTROLLER X (48 96 mm)

µr SERIES RECORDERS VIEW RECORDERS 4365 & 4375 Recorders FUNCTIONS FEATURES

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

Process displays For standard signals, temperature, resistance measurement

MODEL: R30US4. Remote I/O R30 Series

High Performance Process & Temperature Controllers

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

UT750. Relay. 150mm. UT s contact. Relay (Use one with a relay coil rating less than the UT s contact rating.) 150mm. Recommended Terminal Lugs

Temperature Controllers E5 J

SHIMADEN DIGITAL CONTROLLER

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

General Specifications

VIEW RECORDERS SPECIFICATIONS

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

General Specifications

Digital indicator for panel mounting With multi-function input Model DI25


SDC40A. DigitroniK TM Digital Indicating Controller RSW. Control unit PID (8) Auto tuning+ Neuro & Fuzzy RUN/READY R/L LSP.

DigitroniK TM Digital Indicating Controller SDC20

General Specifications

UP550 O.C. Relay. UP s contact. 150mm. Relay. (Use one with a relay coil rating less than the UP s contact rating.) 150mm. Recommended Terminal Lugs

Excellent low-cost Process & Temperature Controllers

General Specifications

PROGRAMMABLE CONTROLLER

General Specifications

Single Loop Controller SDC35/36

DC1010/DC1020/DC1030/DC1040

ADAM 4000/4100 Series

Analogue temperature controllers

General Specification

General Specifications

General Specifications

General Specifications

HYBRID RECORDER OUTLINE

Hawk 3 Digital Panel Meter / Controller

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

DCP552B Mark II. DIGITRONIK TM Programmable Controller. Control operation block. Mode transition. PID control Auto-tuning.

MODEL: TC10EM. Temperature Controller TC10 Series

General Specifications

General Specifications

PROGRAMMABLE CONTROLLER

Resistance Temperature Device Conversion Module

PROGRAM CONTROLLER OUTLINE

SPECIFICATIONS Digital Indicator 1. General

C1901 Single Pen Circular Chart Recorder. C1901 a rugged, reliable recorder for all single channel recording applications

APPENDIX APPENDIX A 1

Transcription:

General Specifications GS 0F01D0E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision 1/8 DIN alarm instrument provided with universal input. For excellent monitoring operability, it has a large PV display with the PV display color changing function Active Color PV Display. It is provided with four alarm setting points or setting outputs (one is optional function). A retransmission output and 1 V DC loop power supply are also provided as standard. A communication function and V DC loop power supply are available optionally. Main Features Extralarge digital display allows the indicated values to be read even from a long distance. LEDs of 0 mm height are used for the PV display. The PV display color changing function "Active Color PV Display" is provided. PV display color is changed from green to red and vice versa when an alarm occurs. The color also can be fixed in green or red. Universal input allows simple setting of the input type (thermocouple, RTD or mv) and range from the front panel. Various communication functions are provided. Communication is possible with personal computer, programmable logic controller, and other instruments. Function Block Diagram Input processing Bias computation Firstorder lag computation V DC loop power supply Power supply PV indication Resets the PV peak and bottom values. Contact Retransmission output or 1 V DC loop power supply Current Alarm output Alarm 1,,, * *Alarm output is an optional function. UM1 Functional Specifications Indication in green or red color UM1E E indicates the model with expanded functions. Signal Computation Functions computation: Bias addition ( 100.0 to 100.0% of range span), firstorder lag filter (time constant off, 1 to 0 s) Contact input: Retains and displays peak and bottom values of values. Resets the peak and bottom values. Alarm Functions Six types of alarm functions are provided. The alarm status is indicated by the alarm lamp on the front panel. Also, four points among them (one is optional function) can be output as relay contact outputs. Alarm types: PV high limit, PV low limit, Deenergized on PV high limit, Deenergized on PV low limit, Fault diagnosis, and FAIL output Alarm setting ranges: PV alarms: 100.0 to 100.0% of range Alarm hysteresis: 0.0 to 100.0% of range span Delay timer: 0.00 to 99.9 (minute, second) An alarm is output when the delay timer expires after the alarm setpoint is reached. Setting for each alarm is possible. Standby action: Standby action can be set to make PV alarm OFF during startup. Fault diagnosis alarm: Input burnout, A/D conversion error or thermocouple RJC error FAIL output: Abnormality in software or hardware. Display and Operation Functions PV display: digit digital display for engineering data Parameter display: digit digital display for various data, including parameters GS 0F01D0E Copyright Apr. 00 (MC) th Edition Apr. 00 (KP)

Status indication: Alarm indicator lamp Four lamps; AL1, AL, AL and AL PV display color changing function Active Color PV Display : (Factoryset default : Fixed in red mode) This function automatically changes PV display color by the action described below. Greentored or redtogreen changing action is selectable. Link to alarm 1 mode : Alarm OFF : green, Alarm ON : red Setting of Alarm OFF : red, Alarm ON : green is possible. Link to alarms 1 and mode: Alarm OFF : green, Alarm ON : red Setting of Alarm OFF : red, Alarm ON : green is possible. PV limit mode : Within the preset PV range : green, Out of the preset PV range : red Setting of Within the preset PV range : red, Out of the preset PV range : green is possible. The range (high limit and low limit) is changeable using a parameter. Fixed color mode : PV display color is fixed in green or red. Operation keys: and keys: Increase or decrease setpoints or various parameters. SET/ENT key: Sets set data, calls or switches various parameters. SELECT display: Allows selection and registration of frequently changed parameters from the operating parameters during operation. For example, if the alarm setpoint 1 is registered in the SELECT display, the setpoint can easily be displayed during operation. Security function: Operation can be keylocked by setting a parameter. Opeation can be inhibited by a password. Communication Functions (Optional Function) The communication function, provided with the instrument, allows connection to a personal computer, and programmable logic controller. Communication protocol Computer link communication: Communication protocol with a personal computer Ladder communication: Communication protocol with programmable logic controller. MODBUS Communication: Communication protocol with a personal computer or PLC. Communication interface Communication protocol: Computer link, ladder communication or MODBUS communication Standards: EIA RS8 Maximum number of connectable controllers: 1 GREEN series controllers Maximum communication distance: 1,00 m Communication method: Twowire half duplex, or fourwire half duplex, startstop synchronization system, nonprocedural Communication rate: 00, 00, 00, 800, or 900 bps LED display unit (for PV) Displays PV and error code when errors are detected. Active color PV display Indication in green or red color. LED display unit Displays setting items/values of parameters. Status lamps Indicate alarm status (AL1,,, ). Operation keys Increase/decrease the setting data (, ). Select parameter, enter the setting data (SET/ENT). Sample Structures of Communication Systems Configuration Diagram (1) Computer link communication/modbus communication () Ladder communication Personal computer PLC UM1/UM1 Digital indicator with Alarms UM1/UM1 Digital indicator with Alarms All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0F01D0E th Edition Apr. 0, 0000

Hardware Specifications PV Input Signal Number of input points: 1 Input system: The input type and instrument range can be specified using the input range code shown in the table below with key operation or via communication. Sampling period: 0 ms Input type, instrument range and measurement accuracy: Refer to the table below. Burnout detection: Functions at thermocouple (TC), RTD or standard signal of 0. to V or 1 to V. Upscale, downscale, and off can be specified. For standard signal, set to burnout at 0.1 V or less. Input bias current: 0.0 µa for TC or RTD bterminal Measurement current (RTD): About 0. ma Input resistance: 1 MΩ or more for TC or mv input About 1 MΩ for DC voltage input Allowable signal source resistance: 0 Ω or less for TC or mv input Effects of signal source resistance: 0.1 µv/ω or less kω or less for DC voltage input Effects of signal source resistance: About 0.01%/100Ω Allowable wiring resistance: Maximum 10 Ω/wire (resistance in each of three wires must be equal) for RTD input However, maximum 10 Ω/wire for the range of 10.0 to 10.0 C Wiring resistance effect: ±0.1 C/10 Ω Allowable input voltage: ±10 V DC for TC, mv or RTD input ±0 V DC for DC voltage input Noise rejection ratio: Normal mode 0 db (0/0Hz) or more Common mode 0 db (0/0Hz) or more Input type Input range code Instrument range ( C) Instrument range ( F) Measurement accuracy *1 Unspecified(when shipped from the factry) OFF Set the data item Type"IN" to the OFF option to leave the type undefined. Thermocouple RTD Standard signal DC voltage K J T B S R N E L (DIN) U (DIN) W (DIN) Platinel PR00 W9ReWRe JPt100 Pt100 0. to V 1 to V 0 to V 0 to 10 V 10 to 0 mv 0 to 100 mv 1 8 9 10 1 1 18 0 1 0 1 0 1 00 to 0 C 199.9 to 999.9 C 199.9 to 00.0 C 199.9 to 999.9 C 199.9 to 00.0 C 0.0 to 00.0 C 0 to 1800 C 0 to 00 C 0 to 00 C 00 to 00 C 199.9 to 999.9 C 199.9 to 900.0 C 199.9 to 00.0 C 0.0 to 00.0 C 0 to 00 C 0 to 90 C 0 to 1900 C 0 to 000 C 199.9 to 00.0 C 10.0 to 10.0 C 199.9 to 80.0 C 199.9 to 00.0 C 10.0 to 10.0 C 0.00 to.000 1.000 to.000 0.000 to.000 0.00 to10.00 10.00 to 0.00 0.0 to 100.0 00 to 00 F 0 to 00 F 199.9 to 999.9 F 00 to 00 F 00 to 0 F 199.9 to 0.0 F to 00 F to 100 F to 100 F 00 to 00 F 00 to 1800 F 00 to 00 F 00 to 0 F 199.9 to 0.0 F to 00 F to 00 F to 00 F to 00 F 199.9 to 999.9 F 199.9 to 00.0 F 00 to 10 F 199.9 to 999.9 F 199.9 to 00.0 F Scaling is enable in the following range. 1999 to 9999 199.9 to 999.9 19.99 to 99.99 1.999 to 9.999 ±0.1% of instrument range ±1 digit for temperatures equal to or higher than 0 C, ±0.% of instrument range ±1 digit for temperatures below 0 C ±0.1% of instrument range ±1 digit for temperatures equal to or higher than 00 C ±% of instrument range ±1 digit for temperatures below 00 C ±0.1% of instrument range ±1 digit ±0.1% of instrument range ±1 digit ±0.% of instrument range ±1 digit for temperature below 0 C ±0.1% of instrument range ±1 digit for temperatures equal to or higher than 0 C ±0.% of instrument range ±1 digit for temperatures below 0 C ±0.% of instrument range ±1 digit ±0.1% of instrument range ±1 digit ±0.% of instrument range ±1 digit for temperatures equal to or higher than 800 C No guarantee of accuracy for temperatures below 800 C ±0.% of instrument range ±1 digit ±0.1% of instrument range ±1 digit (Note 1) (Note ) ±0.% of instrument range ±1 digit (Note 1) ±0.1% of instrument range ±1 digit (Note 1) (Note ) ±0.% of instrument range ±1 digit (Note 1) ±0.1% of instrument range ±1 digit The readout range can be scaled between 1999 and 9999. *1: Performance in the standard operating conditon (at C ± C, ±10%RH, and 0/0Hz power frequency) Note 1: The accuracy is ±0. C of instrument range ±1 digit for a temperature range from 0 to 100 C. Note : The accuracy is ±0. C of instrument range ± 1 digit for a temperature range from 100 to 0 C and 100 to 00 C. All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0F01D0E th Edition Apr. 0, 0000

Reference junction compensation error: ±1.0 C (1 to C) ±1. C (0 to 1 C, to 0 C) Applicable standards: JIS, IEC, DIN (ITS90) for TC and RTD Response time: second or less, % (10 90%) (The time required for transmission output to reach % of the maximum excursion when PV abruptly changes from 10% to 90%) V DC Loop Power Supply for Sensor Supplies power to a twowire transmitter. A resistor (10 to 0 Ω) connected between the indicator and transmitter converts a current signal into a voltage signal, which is then read via the terminal. Supply voltage: 1. to 8.0 V DC Maximum supply current: About 0 ma (only for models with V DC loop power supply) V DC Power Supply Wiring to Twowire Sensor Twowire transmitter 0 madc External resistor (Note) 0Ω 1 to V DC signal 1 Loop power supply 1. to 8.0 V DC Note: Connecting a 0 Ω resistor to the terminals is optional. Model: X0100 (resistor with M. crimpon terminal lugs) Retransmission Output PV is output. Can also be used for 1 V DC loop power supply. Number of output points: 1 Output signal: to 0 ma DC Load resistance: 00 Ω or less Output accuracy: ±0.% of span Performance in the standard operating conditions (at ± C, ±10% RH, and 0/ 0 Hz power frequency) When used for 1 V DC loop power supply: Supply voltage: 1. to 18.0 V DC Maximum supply current: About 1 ma (with a protection circuit for a field short circuit) Contact Input Usage: Resets the displayed PV peak and bottom values. Number of input points: 1 Input type: Nonvoltage contact input or transistor open collector input Input contact rating: V DC, 10 ma or more On/off detection: For nonvoltage contact input, ON = contact resistance of 1 kω or less, OFF = contact resistance of 0 kω or more. For transistor open collector input, ON = V or less, OFF = leak current of 100 µa or less. Minimum status detection hold time: About 1 s Contact Outputs Usage: Alarm output, FAIL output Number of relay contact outputs: (Alarm is optional function.) Alarm1 to relay contact rating: 0 V AC 1A, or 0 V DC 1 A acontact ( terminals are common for every contact output.) (bcontact for FAIL output) Alarm relay contact rating: 0 V AC A, or 0 V DC A (resistance load) terminals (NC, NO and Common), transfer contact Display Unit Specifications PV display unit: digit segment green/red LED, each digit 0 mm in height Parameter display unit: digit segment red LED, each digit 9. mm in height Status indicator lamps: LEDs Safety and EMC Standards Safety:Compliant with IEC/EN10101: 001, approved by CSA1010, approved by UL08. Installation category : CAT. II (IEC/EN1010, CSA1010) Pollution degree : (IEC/ EN1010, CSA1010) Measurement category : I (CAT. I : IEC/ EN1010) Rated measurement input voltage : 10V DC max.(across terminals), 00V AC max.(across ground) Rated transient overvoltage : 100V (Note) Note : It is a value on the safety standard which is assumed by IEC/EN10101 in measurement category I, and is not the value which guarantees an apparatus performance. EMC standards:complies with EN During test, the controller continues to operate with the measurement accuracy within ±0% of the range. Construction, Mounting and Wiring Construction: Dustproof and Dripproof front panel conforming to IP. Material: ABS resin and polycarbonate Case color: Black Weight: About 1 kg or less Dimensions: 9(W) 8(H) 100 (depth from the panel face) (mm) Mounting: Panelmounting type. With right and left mounting hardware (1 each) Sidebyside close mounting is not permitted. Panel cutout dimensions: 9 0.8 0 (W) 0. 0 (H ) (mm) Mounting attitude: Up to 0 degrees upward facing. No downward tilting allowed. Wiring: M. (ISO. mm) screw terminals (for signal wiring, power/grounding wiring as well) All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0F01D0E th Edition Apr. 0, 0000

Power Supply and Isolation Specifications Power Supply Specifications Power supply: Voltage rating at 100 to 0 V AC (±10%), 0/0 Hz Power consumption: Max. 0 VA (Max. 8.0 W) Internal fuse rating: 0 V AC, 1. A timelug fuse Data backup: Nonvolatile memory (service life about 100,000 times of writings) Withstanding voltage: Between primary terminals and secondary terminals: 100 V AC for 1 min Between primary terminals and grounding terminal: 100 V AC for 1 min Between grounding terminal and secondary terminal: 100 V AC for 1 min Between two secondary terminal: 00 V AC for 1 min Primary terminals: Power supply and relay output terminals Secondary terminals: Analog input/output signal terminals, and contact input terminals Isolation resistance: Between power supply terminal and grounding terminal, 00 V DC 0 MΩ or more Grounding: Class D grounding (Class grounding) (grounding resistance of 100 Ω or less) Isolation specifications terminals:. Not isolated from the internal circuit. V DC loop power supply terminals for sensor: Retransmission output terminals: Contact input terminals: Not isolated from communication terminals. Relay contact output terminals: RS8 communication terminals: Not isolated from contact input terminals. Power supply terminals:, Grounding terminals:, Environmental Conditions Normal operating conditions: Ambient temperature: 0 to 0 C 0 to 0 C when using V DC loop power supply for sensor Temperature change rate: 10 C /h or less Ambient humidity: 0 to 90% RH(no condensation) Magnetic field: 00 A/m or less Continuous vibration at to 1 Hz: Peakto peak amplitude of 1. mm or less Continuous vibration at 1 to 10 Hz:.9 m/s or less Shortperiod vibration: 1. m/s, 1 s or less Shock: 1 m/s or less, ms Installation altitude:,000 m or less above sea level Warmup time: 0 minutes or more after power on Transportation and storage conditions: Temperature: to 0 C Temperature change rate: 0 C /h or less Humidity: to 9% RH (no condensation) Effects of operating conditions Effect of ambient temperature: For voltage or TC input: Equal or less than whichever is greater, ±1 µv/ C or ±0.01% of F.S./ C. For RTD input: ±0.0 C/ C (ambient temperature) or less For analog output: ±0.0% of F.S./ C or less Effect of power supply fluctuation (within rated voltage): For analog input: Equal or less than whichever is greater, ±1 µv/10 V or ±0.01% of F.S./10 V. For analog output: ±0.0% of F.S./10 V or less All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0F01D0E th Edition Apr. 0, 0000

<<Contents>> <<Index>> Terminal Arrangements for Standard Type Receiving 0 ma DC Current Signals with the Indicator * When receiving 0 ma DC current signals, set the type to 1 V DC (setpoint 1 ). TC input RTD input * PV retransmission is configured at factory before shipment. Retransmission output 0 Ω 0 ma A 0 ma DC b Load resistance: 00 Ω or less B Note: Connecting a 0 Ω resistor to the terminals is optional. Model: X0100 (resistor with M. crimpon terminal lugs) * If 1 V DC loop power supply is used, retransmission output cannot be used. 1 V DC loop power supply mv/v input Contact input 1.18.0 V DC (1 ma DC max.) V Transistor contact DI1 19 Contact 19 UM DI1 Resets the PV peak and bottom values when DI1 is changed from OFF to ON. * Wiring can only be carried out for indicators with V DC loop power supply. 0 0 Common Contact rating: V DC, 10 ma Min. 0 19 18 1 1 1 1.8.0 V DC (0 ma DC max.) RS8 communication * Wiring can only be carried out for indicators with communication functions. Maximum baud rate: 900 bps SDB() 0 9 8 1 SDA() Alarm output 10 9 8 1 Relay contact output RDB() * Wiring can only be carried out for UM101 or UM10. RDA() NC NO SG Power supply 1 Power supply Contact rating: 0 V AC, A 0 V DC, A (resistance load) 8 L UM CAUTION * Not configured at factory before shipment V DC loop power supply Alarm output AL1 Alarm 1 output Before carrying out wiring, turn off the power to the controller and check that cables to be connected are not alive with a tester or the like because there is a possibility of electric shock. 9 10 N AL AL Relay Allowable range: 100 to 0 V AC ( 10%) (free voltage) 0/0 Hz shared Alarm output Alarm output Common Relay contact rating: 0 V AC, 1 A 0 V DC, 1 A (resistance load) * Wiring can only be carried out for indicators with V DC loop power supply. V DC Power Supply Wiring to Twowire Sensor 1 V DC Power Supply Wiring to Twowire Sensor 1 to V DC signal 0 V External resistor (Note) 0. to.0 V DC signal 100 External resistor (Note) 1 Twowire transmitter Twowire transmitter Loop power supply 1. to 8.0 V DC Loop power 0 ma DC supply 1. to 18.0 V DC 0 ma DC Note: Connecting a 0 resistor to the terminals is optional. Model: X0100 (resistor with M. crimpon terminal lugs) Note: Connecting a 100 resistor to the terminals is optional. Model: X010100 (resistor with M. crimpon terminal lugs) All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0F01D0E th Edition Apr. 0, 0000

External Dimensions and Panel Cutout Dimensions Small bracket 1 91.8 Small bracket Unit: mm 9 8 100 Front of indicator 1 to 10 mm (Panel thickness) General installation 1 min. () 0 min. 0. 0 0.8 9 0 () Normal Allowable Deviation=± (Value of JIS B 00999 tolerance grade IT18) / Model and Suffix Codes UM1 Type Model Suffix Code Description Digital indicator with alarms (provided with retransmission output and 1 V DC loop power supply as standard) 0 Standard type with three alarms Standard type with three alarms (with V DC loop power supply) Optional functions 0 None 1 With communication and additional alarm With additional alarm Standard accessories: Brackets (mounting hardware), unit label, and User s Manuals. Terminal cover (optional part) is provided. Items to be Specified when Ordering Model and suffix codes, necessary/unnecessary of User s Manual or QIC. All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0F01D0E th Edition Apr. 0, 0000