General Specifications
|
|
- Jemimah Stevenson
- 6 years ago
- Views:
Transcription
1 General Specifications Model UT350 Digital Indicating Controller GS 05D0D00E General Model UT350 Digital Indicating Controller is a highly accurate /DIN controller provided with universal input/ output. It has a large display for readings and excellent monitoring operability with the Auto/Man switching key. In addition, heating/cooling control, including PID control with autotuning, the SUPER overshoot suppressing function SUPER and the hunting suppressing function SUPER are available as control functions, and a retransmission of variables and a 5 V DC loop power supply are also equipped as standard. A communication function or V DC loop power supply is available optionally. As described above, the UT350 is a controller provided with higher functions and capability than conventional similarsize controllers. UT350 UT350E E indicates the model with expanded functions. Main Features Extralarge digital display allows the indicated values to be read even from a long distance. LEDs of 0mm height are used for the process variable display. Universal input and output enable users to set or change freely the type of measured inputs(thermocouple, RTD, or DCV), measurement range, type of control output( to 0 ma current, voltage pulse, or relay contact), from the front panel. Parameters can be easily set using a personal computer. ( Parameter setting tool (model LL00) sold separately is required.) Various communication functions are provided. Communication is possible with personal computer, programmable logic controller, and other controllers. Reference point = Measuring input range (0%) Reference point Reference point Measuring input range (00%) Reference point hysteresis = Fixed to 0.5% of the measured input range span. Reference deviation method: PID parameters (No. PID) are selected when the deviation exceeds the reference deviation. This process takes precedence over the reference point method. Reference deviation = OFF or 0. to 00.0% of measured input range span Measuring innput range (00%) Reference deviation No.3PID Functional Specifications Reference point Reference deviation Control Computation Functions Control computation: Can be selected from the following types: Continuous PID control, Timeproportional PID control, Heating/Cooling control (for heating/ cooling type only) or Relay ON/OFF control. Control cycle time: 50 ms Number of sets of target setpoints and PID parameters: Target setpoint and PID selection: PID parameters are provided for every target setpoint and the set of PID parameters are selected at the same time that the setpoint number is selected. Zone PID selection: PID parameters are selected depending on the value of the. For selection, the reference point (PID parameter selection setpoint) or the reference deviation is used. Reference point method: The measuring input range is divided into a maximum of three zones with up to two reference points, and PID parameters are selected (No. PID to No. 3 PID) for every zone. Reference point Measuring innput range (0%) Measured value () No.PID No.PID Autotuning: Available as standard. If autotuning is operated, PID constants are automatically set (limit cycle method). SUPER function: Overshoots generated by abrupt changes in the target setpoint or by disturbances can be suppressed. SUPER function: The function stabilizes the state of control that is unstable due to hunting, etc. without requiring any change in PID constans, when the load and/or gain varies greatly, or when there is a difference between the characteristics of temperature zones. GS 05D0D00E Copyright Feb rd Edition Jun. 00
2 <<Contents>> <<Index>> Control Parameters Setting Range Proportional band = 0. to 999.9% 0.0 to 999.9% for heating/cooling control, 0.0% for ON/OFF control Integral time = to 6,000s, or OFF (manual reset) Derivative time = to 6,000s, or OFF Manual reset value = 5.0 to 05.0% of output range (functions when integral time is off.) ON/OFF control hysteresis = 0.0 to 00.0% of measured input range span (0. to 0.5% for heating/ cooling control) Setpoint rateofchange setting = off, or 0.0 to 00.0%/h or min of measured input range span. A tracking function operates automatically when the setpoint is changed, the power is turned on, or the mode is changed from manual to automatic. Direct/reverse action: The output increase/decrease direction can be defined corresponding to a positive or negative deviation. For heating/cooling control, it is fixed; for the heating side output, reverse, for the cooling side output, direct. Antireset windup: When controller output is limited, normal integration is superseded by an antireset windup computation to suppress overintegration. Control output cycle time = to 000 s (for Timepropotional PID control) (the cooling side output cycle time is also the same when heating/cooling control is used). Preset output value = 5.0 to 05.0% of output range Output tracking: Whether the output bump is provided or not can be selected by changing the PID control mode. Output limiter Upper limit = Lower limit to 05.0% of output range Lower limit = 5.0% of output range to upper limit Heating/cooling dead band = 00.0 to 50.0% for output range Signal Computation Functions Measured input computation: Bias addition (00.0 to 00.0% of measured input range span), and firstorder lag filter (time constant off or to 0 s) Contact input function: Target setpoint selection, Auto/Man operating mode switching, key lock parameter display/ nondisplay switching Target setpoint selection can be done for either a setpoint or setpoint selection. If the setpoint selection is set, Auto/Man mode switching can be used as well. If the setpoint selection is set, Auto/Man switching and key lock parameter display/nondisplay switching cannot be used together. If key lock parameter display/nondisplay switching is used, target setpoint selection and Auto/Man mode switching cannot be used. Alarm Functions Eighteen types of alarm functions are provided. The alarm status is indicated by the alarm lamp on the front panel. Also, three points among them can be output as relay contact outputs. Alarm types: high limit, low limit, Deviation high limit, Deviation low limit, Deenergized on deviation high limit, Deenergized on deviation low limit, Deviation high and low limits, High and low limits within deviation, Deenergized on high limit, Deenergized on low limit, SP high limit, SP low limit, Output high limit, Output low limit, Heater burnout alarm, sensor grounding alarm, Fault diagnostic alarm, FAIL output. Alarm output: 3 points. Any three points can be output as contact outputs among the above alarms. For heating/cooling control, if cooling side output is output as a relay contact, up to two alarm outputs can be used. Setting ranges for, deviation, setpoint and output alarms: /setpoint alarm: 00.0 to 00.0% of measured input range Deviation alarm: 00.0 to 00.0% of measured input range span Output alarm: 5.0 to 05.0% of output range Alarm hysteresis: 0.0 to 00.0% of measured input range span Delay timer: 0.00 to (minute, second) An alarm is output when the delay timer expires after the alarm setpoint is reached. Setting for each alarm is possible. Standby action: Standby action can be set to make / deviation alarm OFF during startup or after SP change until SP reaches the normal region. Heater burnout alarm (optional): Two circuits incorporated A heater burnout alarm is output if the heater current consumption is the burnout detection value or less. This alarm can be used for Relay ON/OFF control or timeproportional PID control. Heater current setting range: 0.0 to 50.0 A Setting accuracy: ± 5% of span ± digit Heater current detecting resolution: 0.5 A Time required until burnout detection is on: 0. s minimum burnout sensor model: CTL6SH(URD Co. Ltd.) Sensor grounding alarm: An alarm is output after detecting a change in control output. If the moving average * of control output is out of the setting range (between the high and low limits of the on/off rate) in spite of the deviation being within a fixed range (on/off rate detection band) and control being in stable condition, the sensor is judged to be in a grounding condition. * Moving average refers to the average value for output values sampled (five times) in every cycle time. High and lowlimit setting range of on/off rate: 5.0 to 05.0% of output range All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition May.,0000
3 <<Contents>> <<Index>> 3 Detection band of on/off rate: 0.0 to 00.0% of measured input range span. Fault diagnostic alarm: Input burnout, A/D conversion error, thermocouple reference junction compensation error FAIL output: Software failure and/or hardware failure When in fail, control output, retransmission output and alarm output become 0% or OFF. Display and Operation Function display: In digit digital display for engineering data Setpoint display: Various data, such as the setpoint (SP), are displayed by selection on the digit digital display. Status indicating lamps: 3 alarm indicator lamps:,, 3 3 setpoint number indicator lamps: SP, SP3, SP (Go out when SP is selected.) MAN operation mode lamp: MAN (lit in MAN mode) Operation keys: and keys: Increase or decrease setpoints and various parameters. SET/ENT key: Used for data setting or callup/selection of various parameters key: Switching of operation mode (Auto/Man) SELECT display: A panel where operating parameters that are frequently changed during operation can be selected and registered. For example, by registering the alarm setpoint in the SELECT display, the setpoint can easily be displayed during operation. Security function: An operationinhibiting mode using a password is provided. Status lamps Alarm(,, 3), Manual(MAN). Setpoint No. (SP, 3, ) in use. Communication port for light loader Parameters are set via communication from a personal computer. Operational keys Increase/Decrease the setting data (, ) Select parameter/enter the setting data (SET/ENT) mode switching () LED display unit (for ) Display, and error code when error is detected. LED display unit (for SP) Display setpoint (SP), output value, and setting item/value of parameters. All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition May.,0000
4 REM MAN SET/ENT DISP REM MAN REM MAN SET/ENT SET/ENT DISP DISP REM MAN SET/ENT DISP REM MAN SET/ENT DISP REM MAN SET/ENT DISP REM MAN SET/ENT DISP REM MAN SET/ENT DISP REM MAN SET/ENT DISP 3 REM MAN SET/ENT DISP 3 REM MAN SET/ENT DISP 3 REM MAN SET/ENT DISP 3 REM MAN SET/ENT DISP <<Contents>> <<Index>> Communication Functions(optional) This controller has a communication function and can be connected to a personal computer, programmable logic controller or other GREEN series controllers. Communication protocol Computer link communication: Communication protocol with a personal computer. Ladder communication: Communication protocol with programmable logic controller. MODBUS communication: Communication protocol with a personal computer or PLC. Coordinated operation: Communication protocol to coordinated operation with two or more GREEN series controllers. The UT350 can be connected as a master station or a slave station. Communication interface Communication protocol: Computer link, ladder communication, MODBUS or coordinated operation. Standards: EIA RS85 Maximum number of connectable controllers: 3 GREEN series controllers Maximum communication distance:,00 m Communication method: Twowire half duplex or fourwire half duplex, startstop synchronization, nonprocedural. Communication rate: 600, 00, 00, 800, or 9600 bps Examples of Communication System Configuration Diagram () Computer link communication () Ladder communication Personal computer PLC UT350/UT30 Digital indicating controller (3) Coordinated operation UP350 Program controller or UT350/UT30 Digital indicating controller UT350/UT30 Digital indicating controller UT350/UT30 Digital indicating controller All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition May.,0000
5 <<Contents>> <<Index>> 5 Hardware Specifications Measured Input Signal Number of input points: Input system: The types of input/measurement ranges can be set using key operation or software from a list of inputs. Input type, measurement ranges and measurement accuracy: Refer to the table below. Input Type Input range code Instrument range ( C) Instrument range ( F) Measurement accuracy * Unspecified(when shipped from the factry) OFF Set the data item input Type"IN" to the OFF option to leave the input type undefined. Thermocouple RTD Standard signal DC voltage K J T B S R N E L (DIN) U (DIN) W (DIN) Platinel PR00 W97Re3W75Re5 JPt00 Pt00 0. to V to 5V 0 to V 0 to 0V 0 to 0mV 0 to 00mV to 370 C 99.9 to C 99.9 to C 99.9 to C 99.9 to 00.0 C 0.0 to 00.0 C 0 to 800 C 0 to 700 C 0 to 700 C 00 to 300 C 99.9 to C 99.9 to C 99.9 to 00.0 C 0.0 to 00.0 C 0 to 00 C 0 to 390 C 0 to 900 C 0 to 000 C 99.9 to C 300 to 500 F 0 to 00 F 99.9 to F 300 to 00 F 300 to 750 F 99.9 to F 3 to 3300 F 3 to 300 F 3 to 300 F 300 to 00 F 300 to 800 F 300 to 300 F 300 to 750 F 99.9 to F 3 to 00 F 3 to 500 F 3 to 300 F 3 to 3600 F 99.9 to F 50.0 to 50.0 C 99.9 to C 99.9 to C 50.0 to 50.0 C 99.9 to F 300 to 560 F 99.9 to F 99.9 to F 0.00 to.000 Scaling is enable in the following.000 to range to to to to to to to to ±0.% of instrument range ± digit for temperatures equal to or higher than 0 C, ±0.% of instrument range ± digit for temperatures below 0 C ±0.5% of instrument range ± digit for temperatures equal to or higher than 00 C ±5% of instrument range ± digit for temperatures below 00 C ±0.5% of instrument range ± digit ±0.% of instrument range ± digit ±0.5% of instrument range ± digit for temperature below 0 C ±0.% of instrument range ± digit for temperatures equal to or higher than 0 C ±0.% of instrument range ± digit for temperatures below 0 C ±0.% of instrument range ± digit ±0.% of instrument range ± digit ±0.5% of instrument range ± digit for temperatures equal to or higher than 800 C No guarantee of accuracy for temperatures below 800 C ±0.% of instrument range ± digit ±0.% of instrument range ± digit (Note ) (Note ) ±0.% of instrument range ± digit (Note ) ±0.% of instrument range ± digit (Note ) (Note ) ±0.% of instrument range ± digit (Note ) ±0.% of instrument range ± digit The readout range can be scaled between 999 and *: Performance in the standard operating conditon (at C ± C, 55±0%RH, and 50/60Hz power frequency) *: To receive a to 0mA DC sgnal, select a standard signal of to 5V DC and connect it to a 50 ohm resistor. This resistor is optional. Model & suffix code : X0050 (resistor with M3.5 crimpon terminal lugs) Note : The accuracy is ±0.3 C of instrument range ± digit for a temperature range from 0 to 00 C. Note : The accuracy is ±0.5 C of instrument range ± digit for a temperature range from 00 to 0 C and 00 to 00 C. Sampling period: 50 ms Burnout detection: Functions with a thermocouple (TC), RTD, standard signal 0. to V DC, and to 5 V DC. Can be specified as upscale, downscale, and off. For standard signal, judged as burnout at 0. V or less. Input bias current: 0.05 µa (for TC/RTD bterminal) Measuring current(rtd): about 0.3mA Input resistance: MΩ or more for TC/mV input About MΩ for DC voltage input Allowable signal source resistance: 50 Ω or less; effect of permissible signal source resistance 0. µv/ω or less for TC/mV input k Ω or less; effect of permissible signal source resistance 0.0%/00 Ω or less for DC voltage input Allowable leadwire resistance: Max. of 50 Ω/wire (resistance in each of three wires must be equal) for RTD input However, 0 Ω/wire for a maximum range of 50.0 to 50.0 C. Effect of permissible leadwire resistance ± 0. C/0 Ω or less All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition May.,0000
6 <<Contents>> <<Index>> Allowable input voltage: ± 0 V DC for TC/mV/RTD input ± 0 V DC for DC voltage input Noise rejection ratio: Normal mode 0 db (50/60 Hz) or more mode 0 db (50/60 Hz) or more Referencejunction compensation error: ±.0 C (5 to 35 C), ±.5 C (0 to 5 C, 35 to 50 C) Applicable standards: JIS, IEC, or DIN(ITS90) for TC and RTD V DC Loop Power Supply for Sensor The controller supplies power to a twowire transmitter. Place a resistor (0 to 50Ω) between the controller and the transmitter, convert a current signal to a voltage signal, and read it from the input..6 to 8.0 V DC, maximum supply current is about 30mA (only for models with V DC loop power supply). V DC Power Supply Wiring to Twowire Sensor Twowire transmitter 0mADC External resistor (Note) input 50Ω to 5 V DC signal 3 Loop power supply.6 to 8.0 V DC Note: Connecting a 50 Ω resistor to the termanals is optional. Model: X0050 (resistor with M3.5 crimpon terminal lugs) Retransmission Output Either, target setpoint, or control output is output. Either the retransmission output or the 5V DC loop power supply can be used. Number of output points: Output signal: to 0 ma DC Load resistance: 600 Ω or less Output accuracy: ± 0.3% of span * Performance in the standard operating conditions (at ± C, 55± 0% RH, and 50/ 60 Hz power frequency) 5V DC loop power supply: Supply voltage is.5 to 8.0 V DC. Maximum supply current is about ma (with a protection circuit for a field shortcircuit). Control Outputs The control output is of a universal scheme and can be selected from the following types of outputs. In the case of heating/cooling control, it is also selectable from these outputs. However, if the cooling side output is a relay contact output, the alarm3 cannot be used, and similarly if the cooling side output is a voltage pulse or current output, the retransmission output/5 V DC sensor power supply cannot be used. Current output Number of output points: or ( for heating/cooling type), switched between voltage pulse output and current output. Output signal: to 0 ma Load resistance: 600 Ω or less Output accuracy: ±0.3% of span * Performance in the standard operating conditions (at ± C, 55± 0% RH, and 50/60 Hz power frequency) 6 Voltage pulse output Number of output points: or ( for heating/cooling type), switched between voltage pulse output and current output. Output signal: On voltage = V DC or more (load resistance of 600 Ω or more; current on shortcircuiting about 30 ma) Off voltage = 0. V DC or less Resolution: 0 ms Relay contact output Number of output points: or ( for heating/cooling type) Output signal: Three terminals for NC, NO, and transfercontact Contact rating: 50 V AC, 3 A or 30 V DC, 3A (resistive load) Resolution: 0 ms Contact Inputs Usage: Target setpoint selection, Auto/Man mode switching, or Key lock parameter display/nondisplay switching Number of input points: Input type: Nonvoltage contact input or transistor open collector input Input contact rating: V DC, 0 ma or more (for nonvoltage contact input) On/off determination: For nonvoltage contact input, ON = contact resistance of kω or less, OFF = contact resistance of 0 kω or more. For transistor contact input, ON = V or less, OFF = leakage current of 00 µa or less. Minimum retention time for status detection: about second Contact Outputs Usage: Alarm output, FAIL output, and others Number of relay contact output points: 3 Relay contact rating: 0 V AC, A or 30 V DC, A (COM terminal is common for every contact output.) Display Specifications display: digit, 7segment red LED; character height 0 mm Setpoint display: digit, 7segment red LED; character height 9.3 mm Status indicating lamps: LEDs Conformance to Safety and EMC Standards Safety:Compliant with IEC/EN600: 00, approved by CSA00, approved by UL508. Installation category : CAT. II (IEC/EN600, CSA00) Pollution degree : (IEC/ EN600, CSA00) Measurement category : I (CAT. I : IEC/ EN600) Rated measurement input voltage : 0V DC max.(across terminals), 300V AC max.(across ground) Rated transient overvoltage : 500V (Note) Note : It is a value on the safety standard which is assumed by IEC/EN600 in measurement category I, and is not the value which guarantees an apparatus performance. All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition May.,0000
7 <<Contents>> <<Index>> EMC standards: Complies with EN636. The instrument continues to operate at a measuring accuracy of within ±0% of the range during tests. Construction, Mounting, and Wiring Construction: Dustproof and Dripproof front panel conforming to IP55. For sidebyside close installation, the controller loses its dustproof and dripproof protection. Material: ABS resin and polycarbonate Case color: Black Weight: Approx. kg or less External dimensions: 96 (width) 96 (height) 00 (depth) mm Mounting : Direct panel mounting; mounting bracket, one each for upper and lower mounting Panel cutout dimensions: (width) (height) mm Mounting attitude: Up to 30 degrees above the horizontal. No downward tilting allowed. Wiring: M3.5 (ISO 3.5 mm) screw terminals (signal wiring and power/ground wiring as well) Power Supply Specifications and Isolation Power supply: Rated at 00 to 0 V AC (±0%), 50/60 Hz Power consumption: MAX. 0 VA (MAX. 8.0 W) Internal fuse rating: 50 VAC,.6A timelug fuse Memory backup: Nonvolatile memory (Service life approx. 00,000 times of writings) Withstanding voltage: 500 V AC for minute between primary and secondary terminals. (Note) 500 V AC for minute between primary and ground terminals. (Note) 500 V AC for minute between ground and secondary terminals. 500VAC for minute between two secondary terminals. Primary terminals = Power and relay output terminals Secondary terminals = Analog I/O signal terminals, voltage pulse output terminals, contact input terminals Note. The withstanding voltage is specified as 00V AC perminute to provide a margin of safety. Isolation resistance: 0 MΩ or more when 500 V DC voltage is applied between the power terminals and ground terminal. Grounding: Class D grounding (grounding resistance of 00 Ω or less) Isolation specifications: Measured input terminal: Isolated from other I/O terminals. Not isolated from internal circuits. 5 V DC loop power supply terminals: Not isolated from 0mA analog output and voltage pulse control output. Isolated from other I/O terminals and internal circuit. V DC loop power supply terminals: Isolated from other I/O terminals and internal circuit. Control output (current or voltage pulse) and retransmission terminals: Not isolated between control output terminals and retransmission output terminals. Isolated from other I/O terminals and internal circuits. Relay contact control output terminals: Isolated from other I/O terminals and internal circuits. Contact input terminals: Not isolated from other contact input terminals mutually, and communication terminals. Isolated from other I/O terminals and internal circuits. Relay contact alarm output terminals: Isolated from other I/O terminals and internal circuits. RS85 communication terminals: Not isolated from contact input terminals. Isolated from other I/O terminals and internal circuits. Power supply terminals: Isolated from other I/O terminals, ground terminal, and internal circuits. Ground terminal: Isolated from other I/O terminals, power terminals, and internal circuits. Environmental Conditions Normal operating conditions: Ambient temperature: 0 to 50 C (0 C or less for mounting of instruments sidebyside) Ambient temperature change limit: 0 C /h or less Ambient humidity: 0 to 90% RH (no condensing) Magnetic field: 00 A/m or less Continuous vibration (5 to Hz): Peaktopeak amplitude of. mm or less Continuous vibration ( to 50 Hz):.9 m/s or less Shortperiod vibration:.7 m/s, 5s or less Shock: 7 m/s or less, ms Installation altitude:,000 m or less above sea level Warmup time 30 minutes or more Transportation and storage conditions: Temperature: 5 to 70 C Temperature change limit: 0 C /h or less Humidity: 5 to 95% RH Effects of operating conditions Effect of ambient temperature: For voltage or TC inputs: Whichever is greater, ± µv/ C or ±0.0% of F.S./ C For RTD inputs: ±0.05 C/ C (ambient temperature) or less for RTD input For analog output: ±0.05% of F.S./ C or less Effect of power supply fluctuation (within rated voltage range): For analog input: Equal to or less than whichever is greater, ± µv/0 V or ± 0.0% of F.S./0 V For analog output: ±0.05% of F.S./0 V or less 7 All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition May.,0000
8 <<Contents>> <<Index>> 8 Function Block Diagram for Standard Type input terminals, and 3 Communication terminals to 7 (when parameter DIS=) Contact input INPUT RS85 DI DI Input selection Unit selection Input range conversion Input bias Input filter SP.NO Target setpoints to REMOTE LOC SP.NO=0 SP.NO= to Target setpoint ramprate function Manual operation Control computation MAN AUTO AUTO (ON)/MAN (OFF) switching Preset output Output limiter STOP RUN * V loop power supply OT 5 V loop power supply Retransmission output Alarm function Control output RET LPS Terminals and OUTPUT Current or pulse terminals 6 and 7 OUTPUT Relay terminals, and 3 OUTPUT /RET Current terminals and 5 DO DO DO3 Alarm Alarm Alarm 3 *: If the setup parameter DIS (DI function selection) is set to, when the contact input is ON (stop state), that controller outputs the preset output value. Legend Terminal Parameter Function Analog signal Contact signal Front panel key All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition May.,0000
9 <<Contents>> <<Index>> 9 Function Block Diagram for Heating/Cooling Type input terminals, and 3 Communication terminals to 7 (when parameter DIS=) Contact input INPUT RS85 DI DI Input selection Unit selection Input range conversion Input bias Input filter REMOTE SP.NO=0 SP.NO Target setpoints to LOC SP.NO= to Target setpoint ramprate function Manual operation Control computation MAN AUTO AUTO (ON)/MAN (OFF) switching Heating/cooling computation Heatingside output limiter Coolingside output limiter Heatingside preset output * * Coolingside preset output OT OT 5 V loop power supply Retransmission output Alarm function Heatingside output Coolingside output RET OUTPUT Current or pulse terminals 6 and 7 DO3 OUTPUT OUTPUT OUTPUT DO DO Relay /RET Alarm Alarm Relay Current or pulse terminals terminals Current, and 3 and 5 terminals and 5 *: If the setup parameter DIS (DI function selection) is set to, *: If when the setup the contact parameter input DIS is (DI ON function (stop state), selection) that controller is set to, outputs the preset output value. when the contact input is ON (stop state), that controller outputs the preset output value. Legend Terminal Parameter Function Analog signal Contact signal Front panel key All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition May.,0000
10 <<Contents>> <<Index>> 0 Standard Type, Terminal Arrangements Receiving 0 ma DC Current * Wiring can only be carried out for controllers with V DC loop power supply. Note: Select this option from the OT parameter. * Time proportional PID relay contact output is configured at factory before shipment. Control output Signals with the Controller input * Not configured at factory before shipment * When receiving 0 ma DC current signals, RS85 communication * Wiring can only be carried out Relay contact output set the input type to 5 V DC (setpoint ). RTD input TC input V DC loop power supply for controllers with communication functions. Maximum baud rate: 9600 bps NC A SDB() NO b SDA() 50 Ω 0mA 3 3 COM 3 B mv/v input VDC RDB() 5 (30 ma DC max.) 6 Contact rating: 50 V AC, 3 A 30 V DC, 3 A (resistance load) RDA() Note: Connecting a 50 Ω resistor to the terminals is optional. Model: X0050 (resistor with M3.5 crimpon terminal lugs) SG 7 Alarm output UT 6 Alarm output 3 5 Alarm output Relay 3 Alarm3 output * retransmission is configured at factory before shipment. Retransmission output 7 COM Relay contact rating: 0 V AC, A 30 V DC, A (resistance load) 0 ma DC Control output 5 Power supply CAUTION Load resistance: 600 Ω or less Current/voltage pulse output * If 5 V DC loop power supply is used, retransmission output cannot be used. 5 V DC loop power supply Note:Select this option from the OT parameter. Power supply 8 L 6 Before carrying out wiring, turn off the power to the controller and check that cables to be connected are not alive with a tester or the like because there is a possibility of electric shock. 0 ma DC, voltage pulse ( V) 9 N.58.0VDC ( ma DC max.) Allowable range: 00 to 0 V AC ( 0%) * DIS is a setup parameter. (free voltage) 50/60 Hz shared Changing DIS setpoint allows you to change the function of external contact input. Contact Transistor contact 5V Correspondence between parameter DIS and external contact input functions UT DI When DIS= When DIS=3 When DIS= When DIS= (Factoryshipped setting) When DIS=OFF 9 DI 5V 9.SP when DI=ON.SP when DI=OFF When switching target SP to :.SP.SP3.SP.SP Hides the LOCK parameter when DI=ON. Shows the LOCK parameter when DI=OFF..SP when DI=ON.SP when DI=OFF No function CT * This wiring is only Heater current possible for a controller detection input with a heater burnout alarm. 9 8 DI COM DI STOP when DI=ON RUN when DI=OFF OFF ON OFF ON OFF OFF ON ON DI DI AUTO when DI=ON MAN when DI=OFF No function 8 CT 8 No function CT CT 0 0 COM COM 30 Contact rating: V DC, 0 ma or more Note: External Contact Input If the power is turned on when the external contact input is OFF, the mode (SP.NO or ) existing before the power is turned off will be continued. (except for RUN/STOP) * OT is a setup parameter. You can change the settings of the parameter OT to change the control output type. Correspondence between parameter OT and control output types OT=3 OT= OT= OT=0 (factoryshipped setting) Onoff control Relay output (terminals, and ) Current output Time proportional control Voltage pulse output Time proportional control Relay output (terminals, and ) All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition May.,0000
11 <<Contents>> <<Index>> Heating/Cooling Type, Terminal Arrangements Receiving 0 ma DC Current Signals with the Controller Heatingside control output * When receiving 0 ma DC current signals, input * Not configured at factory before shipment TC input RTD input A b 3 3 B * Wiring can only be carried out for controllers with communication functions. Maximum baud rate: 9600 bps RS85 communication Relay contact output * Time proportional PID relay contact output set the input type to 5 V DC (setpoint ). is configured at factory before shipment. * Available if, 7 or 0 is set in the OT (Control Output Type) setup parameter. NC SDB() NO SDA() 50 Ω 0mA 3 3 COM RDB() 5 RDA() 6 Contact rating: 50 V AC, 3 A 30 V DC, 3 A (resistance load) Note: Connecting a 50 Ω resistor to the terminals is optional. Model: X0050 (resistor with M3.5 crimpon terminal lugs) mv/v input Alarm output/coolingside control output SG 7 UT 6 Alarm output 3 5 Alarm output Relay 3 * retransmission is configured at factory before shipment. Alarm3 output or coolingside control output (Note) 5 V DC loop power supply Retransmission output 7 COM Relay contact rating: 0 V AC, A 30 V DC, A (resistance load).58.0vdc ( ma DC max.) 0 ma DC Heatingside control output 5 5 * Available if 5, 6, 8, 9, or is set in the OT (Control Output Type) setup parameter. Current/voltage pulse output Note: The coolingside control output is selected if, 5 or 6 is set in the OT (Control Output Type) setup parameter. The alarm3 output is not available. The controller is factoryset to the coolingside control output (time proportional PID relay contact output). * If 5 V DC loop power supply is used, retransmission output cannot be used. Coolingside control output 0 ma DC, voltage pulse ( V) 6 Power supply Power supply 0 ma DC, 7 voltage pulse ( V) CAUTION * The retransmission output and 5 V DC loop power supply are not available if the coolingside control output is set to continuous output and voltage pulse output L 5 Before carrying out wiring, turn off the power to the controller and check that cables to be connected are not alive with a tester or the like because there is a possibility of electric shock. N * DIS is a setup parameter. Allowable range: 00 to 0 V AC ( 0%) Changing DIS setpoint allows you to change the function of external contact input. (free voltage) 50/60 Hz shared Note: External Contact Input If the power is turned on when the external contact input is OFF, the mode (SP.NO or ) existing before the power is turned off will be continued. (except for RUN/STOP) Contact Transistor contact 5V Correspondence between parameter DIS and external contact input functions UT DI When DIS= When DIS=3 When DIS= When DIS= (Factoryshipped setting) When DIS=OFF 9 DI Heater current detection input 5V 9.SP when DI=ON.SP when DI=OFF When switching target SP to :.SP.SP3.SP.SP Hides the LOCK parameter when DI=ON. Shows the LOCK parameter when DI=OFF..SP when DI=ON.SP when DI=OFF No function * This wiring is only possible for a controller with a heater burnout alarm. CT 8 DI COM 8 DI STOP when DI=ON RUN when DI=OFF OFF ON OFF ON OFF OFF ON ON DI DI No function AUTO when DI=ON MAN when DI=OFF No function 9 8 CT CT 0 0 COM CT COM 30 Contact rating: V DC, 0 ma or more * OT is a setup parameter. You can change the settings of the parameter OT to change the control output type. Correspondence between parameter OT and heatingside/coolingside output types OT=6 OT=7 OT=8 OT=9 OT=0 OT= OT= OT= (factoryshipped setting) OT=5 Heating side: Current output Heating side: Voltage pulse output Heating side: Relay output (terminals, and ) Heating side: Voltage pulse output Heating side: Relay output (terminals, and ) Heating side: Current output Heating side: Voltage pulse output Heating side: Current output Cooling side: Relay output 6 7 Heating side: Relay output (terminals, and ) 3 Cooling side: Voltage pulse output Cooling side: Current output 6 7 Cooling side: Current output Cooling side: Current output Cooling side: Voltage pulse output Cooling side: Voltage pulse output Cooling side: Relay output Cooling side: Relay output The control output types, relay output and voltage pulse output shown in the table above refer to those of time proportional control. To change the type to a relay output for onoff control, select Relay Terminals and change the setpoint of the proportional band to 0. All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition May.,0000
12 <<Contents>> <<Index>> External Dimensions and Panel Cutout Dimensions Unit: mm Large bracket Small bracket to 0 mm (Panel thickness) 7 min. [(N) 969] General installation Sidebyside close installation (53) min. "N" stands for the number of controllers to be installed. However, the measured value applies if N (5) Model and Suffix codes Model Suffix Code Description UT350 Digital indicating controller (provided with retransmission output and 5 V DC loop power supply as standard) Type Optional functions 0 Standard type Heating/cooling type 3 Standard type (with V DC loop power supply) 0 None With communication, Heater burnout alarm With heater burnout alarm Standard Accessories: Brackets (mounting hardware), unit label, User s Manuals, and User s Manual (reference) (CDROM version) Items to be specified when ordering Model and suffix codes, necessary/unnecessary of User s Manual or QIC. All Rights Reserved. Copyright 000, Yokogawa Electric Corporation GS 05D0D00E 3rd Edition May.,0000
13 K Series 00 mm Strip Chart Recorders K Series " (00 mm) Continuous Trace and Multipoint Trace Strip Chart Recorders Up to Four Pens for Continuous Traces Up to Six Inputs for Dot Traces Compact Size High Reliability Memory Card / PC Configuration Option Math, Counters, Timers Option Communications Option Recorders Introduction optional optional K Series strip chart recorders offer a full family of products from a single pen model KCA to the full featured KMB. BarberColman K Series Strip Chart Recorders are available with continuous trace writing pens (up to four) or a multipoint printhead that will provide dot printed traces for up to six inputs. Both the continuous and multipoint trace models are available with either an analog display or a digital display. In addition, the K is available with both digital display and segment bar display. This model also offers several advanced features such as memory card reader, math capabilities, totalizers, timers and counters, and serial communications. Contactless Feedback Input Card Technology Wide Range of Models The K is housed in a compact case that extends less than 9/" behind the mounting panel. It uses 00 mm x 6 m long (" x 5/ feet long) fanfold paper that is easily accessible from the front door. All K models use a stateoftheart optical feedback system with brushless motors. This ensures that the combined motor and feedback system have high reliability and an excellent immunity to electromagnetic interference common to many switching cabinets. Custom chips form the basis of a configurable, high accuracy, isolated input system. Auto calibration provides improved accuracy and stability with longterm calibration free service. By using second order DeltaSigma modulators, each input is continuously sampled to provide integrated values for the measured variable. Data acquisition is updated regularly by digitally interrogating the variables through optical isolators. Each channel has its own measuring circuit to ensure high sample accuracy and fast input response. The lineup of K recorders includes: Model KCA Model KMA Model KCD Model KMD Model KCB Model KMB Continuous Trace Recorder with Analog Display Multipoint Trace Recorder with Analog Display Continuous Trace Recorder with Digital Display Multipoint Trace Recorder with Digital Display Continuous Trace Recorder with Digital Display and Segment Bar Multipoint Trace Recorder with Digital Display and Segment Bar Models KXA and KXD are configured at the factory to the specifications on your order and are ready for immediate use. Model KXB is configurable from the front panel which makes it the ideal instrument for applications where configuration needs to be regularly modified. 50DB00000 BarberColman Company, Loves Park, IL Page 38 of 398
14 K Series 00 mm Strip Chart Recorders Ordering Information (continued) Model KXB Recorder MODEL K B Field No Recorders Fields,, 3,. BASE MODEL KCB ", continuous, bargraph/digital display KMB ", multipoint, bargraph/digital display Field 5. NUMBER OF PENS Model KMB 0 None. Multipoint model Model KCB One trace pen Two trace pens 3 Three trace pens Four trace pens 5 One trace pen with annotating pen 6 Two trace pens with annotating pen 7 Three trace pens with annotating pen 8 Four trace pens with annotating pen Note: Annotating pen required if you want to print the time, date and channel information on the chart. Field 6. INPUTS Model KCB 0 Four fixed Inputs Model KMB Two 3 Three 6 Six Fields 7, 8, 9, 0. OPTION CARDS Four cards maximum. 0 None Normally open (four relay outputs) Normally closed (four relay outputs) 3 SPDT, Form C (four relay outputs) Analog retransmission (two outputs; two cards maximum) 5 Contact inputs (six inputs; one card maximum) Field. MATH 0 None Level Level 3 Totalizers, timers, counters Level, plus totalizers, timers, counters 5 Level, plus totalizers, timers, counters Field 3. MEMORY CARD / COMMUNICATIONS 0 None R Reader only (configuration storage) Reader and 8K card (configuration storage) Reader and 5K card (configuration storage) 3 Reader and M card (configuration storage) Serial communications only 5 Serial communications, reader and M card 6 Reader only (ASCII storage w/configuration) 7 Reader and 5K card (ASCII storage with configuration) 8 Reader and M card (ASCII storage with configuration) 9 Reader, M card (ASCII w/config) and serial communications Field. CHART ILLUMINATION/ PEN OFFSET COMPENSATION 0 No Chart illumination Model KCB only Pen offset compensation 5 Chart illumination and pen offset Field 5. SPECIS 0 None Certified calibration CE (European Community) approval 3 Custom messages (0 messages) CSA testing/labeling 5 Option codes, (Cert. cal. and CE aproval) 6 Option codes, 3 7 Option codes, 8 Option codes, 3 9 Option codes, A Option codes 3, B Option codes,, 3 C Option codes,, D Option codes, 3, E Option codes, 3, F Option codes,, 3, Field. TRANSDUCER POWER SUPPLY 0 None 3 Three channel 6 Six channel Shunts and attenutators to be ordered separately. 50DB00000 BarberColman Company, Loves Park, IL Page 30 of 398
15 3000 SERIES 00MM CHART MULTIPOINT TYPE HYBRID RECORDER MODEL series conforming to CE, UL and CSA are 00mm multipoint type hybrid recorders with a simultaneous display of multichannel data, bargraph display, alarm display/printing and other unique features. Software packages of "KIDS" for data processing of measured values and PASS for programming parameters are available. FEATURES Simultaneous digital displays of multipoint data Simultaneous digital display of 6 points allows measured data to be viewed at a glance. Universal input The recorders accept total 56 ranges of 0 DC voltage ranges, 35 thermocouple ranges and resistance thermometer ranges, and these ranges can be programmed for each channel. Data acquisition software package "KIDS" The data acquisition software package "KIDS" is available for data processing by a personal computer. Engineering software package "PASS" Parameters (including inputs and printings) and message printings can be executed through a personal computer by the engineering software package "PASS". DIMENSIONS Communications interface (option) RSC, RSA or RS85 with MODBUS protocol for easy configuration with your personal computer Clear trend and digital printings Cassette type wiredotting system 6color ink ribbon for clear trend and digital printings Universal power voltage 00VAC to 0VAC, 50/60Hz Chart illumination Convenient to confirm printed data in night or dark places CE, UL and CSA The recorder conforms to the rules of safety standards of CE, UL and CSA (CUL). The front panel is the structure with waterproof and dustproof (IP5). Panel cutout and minimum clearance for installation * 3mm for adding Form A mechanical relay Unit: mm PSE70
16 MODELS Input point 6: 6 points/5 seconds A: 6 points/ second (option) Communications interface (option) N: None A: RSA R: RSC S: RS85 Alarm output/remote contacts (option) 0: None : 6 (MOS relay) alarm outputs remote contacts : 6 (Form C mechanical relay) outputs remote contact (Note ) A: 6 (Form A mechanical relay) outputs remote contacts Others (option) 0: None : Printing format highspeed trace printing Note : Not conforming to CE, UL and CSA INPUT SPECIFICATIONS Number of measuring points: 6 points Input signals: Universal input DC voltage, thermocouple, resistance thermometer DC current (by adding shunt resistors) Range setup: Programming of input types and ranges by keys Scale setup: Programming of maximum values, minimum values and engineering units by keys Accuracy rating: Refer to the table of inputs. Temperature drift: ±0.0% of full scale/ºc [Input signals except resistance thermometer inputs: Converted into reference ranges (reference: the table of inputs)] Measuring cycle: About 5 seconds/6 points Reference junction compensation accuracy: K, E, J, T, N, Platinel li. ±0.5ºC or less R, S, NiMoNi, CRAuFe, WWRe6, WRe5WRe6 U, L ±.0ºC or less (The above errors are added to the accuracy ratings for internal reference junction compensation.) Input resolution: About /56000 (converted into reference ranges) Burnout: For thermocouple inputs and resistance thermometer inputs Upscale burnout, downscale burnout or burnout disable is selectable for each input. Allowable signal source resistance: Thermocouple inputs, DC voltage inputs... kω (burnout disabled) or lower Resistance thermometer inputs... 0Ω or lower (per wire) (same resistance for 3 wires) Input resistance: Thermocouple inputs, DC voltage inputs about 8MΩ DC voltage ±5 V or higher about MΩ Maximum input voltage: Thermocouple inputs, DC voltage inputs (for ±VDC or lower range) ±0VDC or lower DC voltage inputs (for ±5VDC or higher range) ±60VDC or lower Resistance thermometer inputs... ±6VDC or lower Input correction: Zero/span correction and shift correction for each channel Maximum common mode voltage: 30VAC mode rejection ratio: 30dB or more (50/60Hz) Series mode rejection ratio: 50dB or more (50/60Hz) Terminal board: Detachable type, removable for wirings
17 PRINTING SPECIFICATIONS Printing interval: About 5 seconds/point Printing deadband: 0.% Printing system: Wiredot type 6color ribbon Printing color: Trace printing Channel No Colors Red Black Blue Green Brown Purple Digital printing Periodic data printing, digital data printing: Repetition of red, black, blue, green, brown and purple Channel number printing: Same color as trace printing Periodic printing: Range (scale), tag, engineering unit Same color as trace printing Month/day or year/month/day, time, time line, chart speed black List printing: Programmed parameters... Same color as trace printing Others... black Programming change mark: Black Alarm printing: Red Chart: Fanfold type, total width mm, total length 0m Effective chart width: 00mm Chart speed: to 500 mm/hr (Default... 0mm/hr) Periodic data printing: Digital printing of time, channel numbers and measured values on trace printing Interval time (hour, minute) optional programming (limited by chart speeds) Digital data printing: Digital printing of time and measured values by interrupting trace printing on demand. Alarm printing: Alarm activated... Time, channel number, alarm type and level (alarm setpoint No.) in right side of a chart Alarm reset... Time, channel number and level (alarm setpoint No.) in right side of a chart Memory capacity... Maximum 8 data Programming change mark: Marking a black in right side of chart when a parameter is changed Subtract printing: Printing of difference between two channels or between a channel and a referenced value (programmed value) List printing: Printing of year/month/day, chart speed, parameters of each channel and others. Fixedtime printing: Printing of month/day, time, time line, ranges (scales), tags and engineering units every fixedtime (interlocking to chart speed) Skip function: No display or printing of channels of which ranges are not programmed. DISPLAY SPECIFICATIONS Display items: LCD display Simultaneous display of 6channel measured values, or time (year/month/day/hour/minute), alarm activated channels and chart speed Status display: Printing status, key lock and alarm activation ARM SPECIFICATIONS Alarm judgment cycle: Same as measuring cycle Alarm display: Status display "ARM" and flashing of measured value at an alarm activated channel Alarm types: Absolute value alarm, differential alarm, rateofchange alarm Alarm programming: Individual programming for each channel Maximum levels/channel Alarm deadband: 0. to 9.9% of scale programming range (Default: 0.% ) Alarm output: Option (Refer to the list of options.) PROGRAMMING/OPERATION Programming parameters: Time, chart speed, periodic data printing, ranges, scales, engineering units, tags, alarms, burnout, subtract printing, ºC/ ºF, passcode (key lock) (Options: Communications, printing format) Printing operation: RECORD ON/OFF.. Printing on/off FEED Fastfeeding of chart LIST List printing DATA PRINT Digital data printing Data display selection: (Key selection): Measured values display and multipoint sequential bargraph display Measured values display and point continuous bargraph display Time/other displays and point continuous bargraph display 3
18 GENER SPECIFICATIONS Rated power voltage: 00 to 0VAC, 50/60Hz Maximum power consumption: 5VA Environmental conditions: Reference operating condition... Ambient temperature/humidity range: to 5 C, 0 to 80%RH Power voltage: 00VAC ± % Power frequency: 50/60Hz ± 0.5% Attitude: Left/right 0, Forward tilting 0, Backward tilting 0 Warmup time: 30 minutes or longer Normal operating condition Ambient temperature/humidity range: 0 to 0 C, 0 to 80%RH Power voltage: 90 to 6VAC Power frequency: 50/60Hz ± % Attitude: Left/right 0 to 0, Forward tilting 0, Backward tilting 0 to 30 Transportation condition (at the packed condition on shipment from our factory) Ambient temperature/humidity range: 0 to 60 C, 5 to 90%RH (No dew condensation) Vibration: 0 to 60Hz,.9m/s or less Impact: 39m/s or less Storage condition Ambient temperature/humidity range: 0 to 60 C, 5 to 90%RH (No dew condensation) Insulation resistance: Between secondary terminals and protective conductor terminal 0MΩ or more at 500VDC Between primary terminals and protective conductor terminal... 0MΩ or more at 500VDC Between primary terminals and secondary terminals... 0MΩ or more at 500VDC Between alarm terminals (Form C mechanical relay) and other secondary terminals... 0MΩ or more at 500VDC Note: Primary terminals: Power (L, N), Alarm (MOS relay, Form A mechanical relay) Secondary terminals: Input, Alarm (Form C mechanical relay), Remote contacts, Communications Dielectric strength: Between secondary terminals and protective conductor terminal... minute at 500VAC Between primary terminals and protective conductor terminal... minute at 500VAC Between primary terminals and secondary terminals... minute at 00VAC Between alarm terminals (Form C mechanical relay) and other secondary terminals... minute at 000VAC Note: Primary terminals: Power (L, N), Alarm (MOS relay, Form A mechanical relay) Secondary terminals: Input, Alarm (Form C mechanical relay), Remote contacts, Communications Power failure protection: Programmed parameters stored into EEPROM memory Clock circuit sustained for 0 years or longer by a lithium battery (at the operation of 8 hours or longer per day) Case assembly material: Door ABS resin (frame) with glass Enclosure... Steel Color: Door (frame) Black (frame equivalent to Munsell N3.0) Enclosure.. Gray (equivalent to Munsell N7.0) Mounting: Panel mounting Weight: About 3.0kg (full options) Clock accuracy: ± minutes or shorter per 30day (under reference operating conditions, except errors by turning power supply on or off) Terminal screws: Power terminals... M.0 Protective conductor terminals.. M.0 Measuring input terminals. M3.5 Alarm terminals. M3.5 Remote contact terminals... M3.5 Communications terminals. M3.5 Chart illumination: CFL (Cold cathode fluorescent lamp) STANDARDS CE: EN636 A Class A EN60003 A EN EN600 A UL: UL3 CSA (CUL): C., No.00 Front protection: Conforming to IEC59 IP5
19 MEASURING RANGES/ACCURACY RATING/DISPLAY RESOLUTION The accuracy ratings are based on the measuring ranges (under the reference operating condition). For thermocouple inputs, the accuracy of reference junction compensation is not included with the accuracy ratings. The indication equivalent to maximum 00µV or 5ºC may vary under the test environment by EMC directives. [Reference operating condition] Ambient temperature/humidity range: to 5ºC, 5 to 65%RH Power voltage: 00VAC ± % Power frequency: 50/60Hz ± 0.5% Attitude: Left/right 0, Forward tilting 0, Backward tilting 0 Warm up time: 30 minutes or longer Thermocouple Input kinds Measuring ranges Reference ranges Accuracy ratings Display resolution 00 to 300ºC ±3.8mV 0.ºC K 00 to 600ºC ±7.6mV 0.ºC 00 to 370ºC ±69.0mV ºC 00 to 00ºC ±3.8mV 0.ºC E 00 to 350ºC ±7.6mV 0.ºC 00 to 900ºC ±69.0mV ºC 00 to 50ºC ±3.8mV 0.ºC J 00 to 500ºC ±7.6mV ±0.% 0.ºC 00 to 00ºC ±69.0mV ± digit ºC T 00 to 50ºC ±3.8mV 0.ºC 00 to 00ºC ±7.6mV 0.ºC R 0 to 00ºC ±3.8mV ºC 0 to 760ºC ±7.6mV ºC S 0 to 300ºC ±3.8mV ºC 0 to 760ºC ±7.6mV ºC B 0 to 80ºC ±3.8mV ºC 00 to 00ºC ±3.8mV 0.ºC N 00 to 750ºC ±7.6mV 0.ºC ±0.5% 00 to 300ºC ±69.0mV ºC W WRe6 WRe5 WRe6 PtRh0 PtRh0 NiMoNi CR AuFe Platinel II U L 0 to 5ºC ±69.0mV ± digit ºC 0 to 5ºC ±69.0mV ºC 0 to 880ºC ±3.8mV ºC ±0.% 50 to 90ºC ±3.8mV 0.ºC ± digit 50 to 600ºC ±7.6mV 0.ºC 50 to 30ºC ±69.0mV ºC 0 to 80 K ±3.8mV 0. K 0 to 350ºC ±3.8mV 0.ºC 0 to 650ºC ±7.6mV 0.ºC 0 to 395ºC ±69.0mV ±0.5% ºC 00 to 50ºC ±3.8mV ± digit 0.ºC 00 to 500ºC ±7.6mV 0.ºC 00 to 600ºC ±69.0mV 0.ºC 00 to 50ºC ±3.8mV 0.ºC ±0.% 00 to 500ºC ±7.6mV 0.ºC ± digit 00 to 900ºC ±69.0mV ºC K, E, J, T, R, S, B, N: IEC58, JIS C60995 U (CuCuNi), L (FeCuNi): DIN370 WWRe6, WRe5WRe6, PtRh0PtRh5, PtRh0PtRh0, NiMoNi, CRAuFe, Platinel II: ASTM Vol..03 Resistance thermometer Input kinds DC voltage Pt00() Pt00() JPt00 Measuring ranges Reference ranges Accuracy ratings Display resolution 3.8 to 3.8mV ±3.8mV 0µV 7.6 to 7.6mV ±7.6mV 0µV 69.0 to 69.0mV ±69.0mV 0µV 00 to 00mV ±00.0mV 00µV 500 to 500mV ±500.0mV ±0.% 00µV to V ±V ± digit mv 5 to 5V ±5V mv 0 to 0V ±0V 0mV 0 to 0V ±0V 0mV 50 to 50V ±50V 0mV 0 to 50ºC 60Ω ±0.5% ± digit 0.ºC 00 to 300ºC 0Ω ±0.% 0.ºC 00 to 850ºC 00Ω ± digit 0.ºC 0 to 50ºC 60Ω ±0.5% ± digit 0.ºC 00 to 300ºC 0Ω ±0.% 0.ºC 00 to 69ºC 00Ω ± digit 0.ºC 0 to 50ºC 60Ω ±0.5% ± digit 0.ºC 00 to 300ºC 0Ω ±0.% 0.ºC 00 to 69ºC 00Ω ± digit 0.ºC Pt50 00 to 69ºC 0Ω PtCo to 37K 0Ω ±0.% ± digit ±0.5% ± digit Pt00 (): IEC75 (995), JIS C60997 Pt00 (): IEC75 (983), JIS C60989, JIS C JPt00: JIS C6098, JIS C EXCEPTION OF ACCURACY RATINGS 0.ºC 0. K Input kinds Measuring range Accuracy rating K, E, J, T, L 00 to 0ºC ±0.% ± digit R, S 0 to 00ºC ±0.% ± digit B 0 to 00ºC Not specified 00 to 800ºC ±0.5% ± digit N, U 00 to 0ºC ±0.3% ± digit WWRe6 0 to 00ºC ±% ± digit 00 to 00ºC ±0.5% ± digit PtRh0PtRh5 0 to 00ºC ±% ± digit 00 to 00ºC ±0.5% ± digit PtRh0PtRh0 0 to 300ºC ±.5% ± digit 300 to 800ºC ±0.8% ± digit CRAuFe 0 to 0 K ±0.5% ± digit 0 to 50 K ±0.3% ± digit Pt00 () 700 to 850ºC ±0.5% ± digit PtCo to 50 K ±0.3% ± digit Note) The accuracy ratings of thermocouple input are converted accuracy into reference ranges. 5
General Specifications
General Specifications Model UM330 Digital Indicator with Alarms GS 05F0D00E General Model UM330 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent
More informationGeneral Specifications
General Specifications Model UM350 Digital Indicator with Alarms GS 05F0D00E General Model UM350 Digital Indicator with Alarms is a precision alarm instrument with universal input. For excellent monitoring
More informationGeneral Specifications
General Specifications Model UT30 Digital Indicating Controller GS 05D0D00E General Model UT30 Digital Indicating Controller is a highly accurate /8 DIN controller, provided with universal input/ output.
More informationGeneral Specifications
General Specifications GS 05D01D01E Model UT351 Digital Indicating Controller with Active Color PV Display General Model UT351 Digital Indicating Controller is a highly accurate 1/4 DIN controller, provided
More informationGeneral Specifications
General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring
More informationGeneral Specifications
General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with
More informationGeneral Specifications
General Specifications GS 0F01D0E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision 1/8 DIN alarm instrument provided with
More informationGeneral Specifications
General Specifications GS 0F01D01E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision alarm instrument provided with universal
More informationGeneral Specifications
General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.
More informationGeneral Specifications
General Specifications Model UP350 Program Controller GS 05E0D00E General Model UP350 program controller is a precision controller, featuring two program profiles and universal input/output. For easy operation,
More informationGeneral Specifications
General Specifications Model UT Digital Indicating Controller GS 0D01C0E General Model UT Digital Indicating Controller is an intelligent, microprocessor based digital indicating controller with powerful
More informationGeneral Specifications
General Specifications MODEL UT0 Digital Indicating Controller GS 0D01C00E General Model UT0 Digital Indicating Controller is an intelligent, microprocessor based digital indicating controller with powerful
More informationGeneral Specifications
General Specifications MODEL 550 Digital Indicating Controller GS 05D0C00E General Model 550 Digital Indicating Controller is an intelligent, microprocessor based digital indicating controller with powerful
More informationGeneral Specifications
General Specifications Model UT, UT Temperature Controller GS CE-E GENERAL UT series temperature controllers provide only the functions and size you require for your application. /6 DIN sizes is available.
More informationGeneral Specifications
General Specifications Model 0 Digital Indicating Controller GS 0D0C00E General Model 0 Digital Indicating Controller is an intelligent, microprocessor based digital indicating controller with powerful
More informationModels UT350/UT320 Digital Indicating Controllers
User s Manual Models UT350/UT320 Digital Indicating Controllers User s Manual IM 05D01D02-41E IM 05D01D02-41E 4th Edition Blank Page Introduction i Thank you for purchasing the UT350/UT320
More informationModels UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control
User s Manual Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control IM 05D01C02-41E IM 05D01C02-41E 3rd Edition Blank Page Introduction i Thank you for purchasing
More informationModels UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup
Instruction Manual Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup IM 05D01C02-45E IM 05D01C02-45E 1st Edition Blank Page Introduction Thank you
More informationGeneral Specifications
General Specifications UM33A Digital Indicator with Alarms [Style: S9] Overview The UM33A digital indicator with Alarms employ an easy-to-read, 14-segment large color LCD display, along with navigation
More informationDIGITAL PROGRAM CONTROLLER
KP1000 SERIES DIGITAL PROGRAM CONTROLLER The KP1000 series is a 96x96mm digital program controller with the indicating accuracy of ±0.1%, the control cycle of approximately 0.1 seconds and maximum 19 program
More informationGeneral Specifications
General Specifications GS 05P01F31-01EN UT32A Digital Indicating Controller (Entry model) Functional Enhancement Overview The UT32A entry model digital indicating controller is an easily configurable single-loop
More informationModel UT750 Digital Indicating Controller User s Manual for Cascade Control
User s Manual Model UT750 Digital Indicating Controller User s Manual for Cascade Control IM 05D01B02-44E IM 05D01B02-44E 3rd Edition Blank Page Introduction i Thank you for purchasing the
More informationModel UP350 Program Controller
User s Manual Model UP350 Program Controller User s Manual IM 05E01D02-41E IM 05E01D02-41E 2nd Edition Blank Page Introduction i Thank you for purchasing the UP350 program controller. How to
More informationModel UT551 Digital Indicating Controller with Active Color PV Display and Embedded Ethernet User s Manual for Single-loop Control
User s Manual Model UT551 Digital Indicating Controller with Active Color Display and Embedded Ethernet User s Manual for Single-loop Control IM 05D01C03-41E IM 05D01C03-41E 4th Edition Introduction
More informationDIGITAL INDICATING CONTROLLER
DB00 SERIES DIGITAL INDICATING CONTROLLER The DB00 series is a digital indicating controller with the indicating accuracy of ±0.% and the control cycle of approximately 0. seconds. Various functions including
More informationHow to Install CAUTION. Panel. 150mm. 150mm. Direction to insert the controller Insert the controller into the opening at the front of the panel.
User s IM DDE This manual describes installation, wiring, and other tasks required to make the ler ready for operation.. Safety Precautions. Model and Suffix Codes. How to Install. How to Connect Wires.
More informationPROCESS & TEMPERATURE CONTROLLERS
PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs
More informationGeneral Specifications
General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter
More informationGeneral Specifications
General Specifications GS 05P03D21-01EN UM33A Digital Indicator with Alarms Functional Enhancement Overview The UM33A digital indicator with Alarms employ an easy-to-read, 14-segment large color LCD display,
More informationTemperature Controllers E5 J
Temperature Controllers Advanced PID Controller with Fuzzy Logic-Based Adaptive Tuning Provides Optimum Performance Available in 3 standard DIN sizes: Choose 1/4, 1/8 and 1/16 DIN Fuzzy adaptive tuning
More informationModel UP550 Program Controller User s Manual for Loop Control with PV Switching
User s Manual Model UP550 Program Controller User s Manual for Loop Control with Switching IM 05E0C0-46E IM 05E0C0-46E 3rd Edition Blank Page Introduction i Thank you for purchasing the UP550
More informationFuzzy Temperature Controllers E5AF
Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate
More informationGeneral Specifications
General Specifications GS 05P08D81-01EN UT32A-D/MDL Digital Indicating Controller (Dual-loop, DIN Rail Mounting Type) Functional Enhancement Overview The UT32A-D/MDL controller is a dual-loop controller
More informationGeneral Specifications
General Specifications GS 77J0A070E Model VJA7 Distributor (Multifunction) (Isolated Singleoutput and Isolated Dualoutput Types) Overview This plugin type distributor is used in combination with wire type
More informationGeneral Specifications
General Specifications GS 05D0B00E Model UT750 Digital Indicating Controller (with Custom Computation) General Model UT750 Digital Indicating Controller is an intelligent, microprocessor based digital
More information6/12/24 Dot Printing Model Smart Recorder SRF206/212/224
No. CP-SS-E // Dot Printing Model Smart Recorder SRF0// The Smart Recorder SRF 0// Dot Printing Model accepts DC voltage, thermocouple, resistance temperature detector (RTD), communications and ON/OFF
More informationGeneral Specifications
General Specifications GS 05P08D3101EN UT32AD Digital Indicating Controller (Dualloop, Panel Mounting Type) Functional Enhancement Overview The UT32AD dualloop digital indicating controllers employ an
More informationMICRO-CONTROLLER X (48 48 mm)
PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature
More informationSHIMADEN DIGITAL INDICATORS
Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large
More informationModel UP351 Program Controller
User s Manual Model UP351 Program Controller User s Manual IM 05E01D12-41E IM 05E01D12-41E 4th Edition Blank Page Introduction i Thank you for purchasing the UP351 program controller. How to
More informationGeneral Specifications
General Specifications 35A/32A Digital Indicating Controllers [Style: S1] Overview The 35A/32A digital indicating controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation
More informationDigital Controller Intelligent, User-friendly Digital Controller and Programmer Controlled with ease with a support software which is input via the communication jack on the front panel. Minute adjustment
More informationModel UP750 Program Controller User s Manual for Dual-loop Control
Instruction Manual Model UP750 Program Controller User s Manual for Dual-loop Control IM 05E0B0-5E IM 05E0B0-5E st Edition Blank Page Introduction i Thank you for purchasing the UP750 program
More informationAPPENDIX APPENDIX A 1
A 1 SPECIFICATIONS Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 7VA 4VA/2.5W Sensor input Thermocouple
More informationSHIMADEN PROGRAM CONTROLLER
Shimaden, Temperature and Humidity Control Specialists C %RH SHIMADEN PROGRAM CONTROLLER approved BASIC FEATURES Full multi-input and multi-range performance User selectable Thermocouple, RTD, V, mv and
More informationHigh Performance Process & Temperature Controllers
C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal
More informationSHIMADEN DIGITAL INDICATORS
Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16 & SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright
More informationMICRO-CONTROLLER X (96 96 mm)
PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature
More informationDC1010/DC1020/DC1030/DC1040
05/0 0-10-10-0-EN Page 1 of DC1010/DC1020/DC100/DC1040 DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of functionality and
More informationEasy-to-read in either English, French, or German; 20-digit, 2-line display; 6-channel simultaneous display possible
PHA & PHC STRIP CHART RECORDERS WITH BRILLIANT SIX-COLOR PRINTING Why use dot-matrix or fiber-tip pen printing when Fuji Electric s patented, cutting-edge recording technology offers an affordable inkjet
More informationµr SERIES RECORDERS VIEW RECORDERS 4365 & 4375 Recorders FUNCTIONS FEATURES
4365 & 4375 Recorders VIEW RECORDERS Splash and dust-proof door permits use even in poor environments. (Based on DIN 40050-IP54). Depth is a mere 220 mm, enabling significant instrument panel space savings.
More informationVIEW RECORDERS SPECIFICATIONS
SPECIFICATIONS Input points: µr1000:1,2,3,4,(pen),6(dot)point µr1800:1, 2, 3, 4, (pen), 6, 12, 18, and 24 (dot) point Input signals, range, and measurement range limits: Input RANGE Range 20 mv 20.00 to
More informationHYBRID RECORDER OUTLINE
Specifications Sheet No.SPEC-33E (st Edition) RM0C HYRID RECORDER OUTLINE RM0C is 00mm calibrated hybrid recorder in a 44x44 DIN front panel and short depth of 50mm case housing. The recorder has versatility
More informationModel UT750 Digital Indicating Controller User s Manual for Cascade Primary-loop Control
User s Manual Model UT750 Digital Indicating Controller User s Manual for Cascade Primary-loop Control IM 05D01B02-42E IM 05D01B02-42E 3rd Edition Blank Page Introduction i Thank you for purchasing
More informationFuzzy Temperature Controllers E5EF
Fuzzy Temperature lers EEF / DIN lers Combine Fuzzy and PID For Fast Response to Process Disturbances dvanced PID control for optimal response during startup and steadystate operation Fuzzy and PID control
More informationExcellent low-cost Process & Temperature Controllers
C22 C62 C82 C83 Excellent low-cost Process & Temperature Controllers C72 C42 R22 01. High Quality LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. The Fast Sampling Rate in 200
More informationJacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)
Temperature Controller with Built-in SSR SB SB General Description SB is a channel temperature controller with Built-in SSR (Solid state relay) designed for flexible heating solutions such as heat trace
More information- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION
ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS
More informationMICRO-CONTROLLER X (48 96 mm)
PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature
More informationGeneral Specifications
General Specifications 35A/32A Digital Indicating Controllers [Style: S5] Overview The 35A/32A digital indicating controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation
More informationMODEL: M2XU MODEL: M2XU [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and
More informationDC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification
01 May 20 30-10-10--EN Page 1 of DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of
More informationModel UP550 Program Controller User s Manual for Cascade Primary-loop Control
Instruction Manual Model UP550 Program Controller User s Manual for Cascade Primary-loop Control IM 05E0C02-42E IM 05E0C02-42E st Edition Blank Page Introduction i Thank you for purchasing
More informationAnalogue temperature controllers
Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications
More informationDPR100 C/D PEN AND MULTIPOINT 100 mm DIGITAL RECORDERS
PEN AND MULTIPOINT 100 mm DIGITAL RECORDERS EN0I-6021 06/2003 PRODUCT SPECIFICATION SHEET PRODUCT DESCRIPTION The DPR 100 C and D recorders are designed to meet the recording needs for most recording applications.
More informationCompoBus/D-type Digital Controller
CompoBus/D-type Digital Controller Digital Controller for the CompoBus/D and Conforming the DeviceNet Conforms the DeviceNet and connects a Programmable Controller without any programming. High performance
More informationSDC40A. DigitroniK TM Digital Indicating Controller RSW. Control unit PID (8) Auto tuning+ Neuro & Fuzzy RUN/READY R/L LSP.
No. CP-SS-580E SDC40A DigitroniK TM Digital Indicating Controller Overview The DigitroniK TM SDC40A is a compact (96mm x 96mm) digital controller. The SDC40A features a wide variety of input options: thermocouples,
More informationDIN rail mounting temperature controller with current transformer input deltadue series D1 line
BT.. D/E S E R I E S DIN rail mounting temperature controller with current transformer input deltadue series D line The controller with load control The deltadue series includes a powerful DIN rail mounting
More informationSHIMADEN DIGITAL INDICATOR
Shimaden, Temperature and Humidity Control Specialists C %RH Series SD24 & KR16A SHIMADEN DIGITAL INDICATOR BASIC FEATURES ohigh Accuracy ±0.1% FS+1 digit o1/1000ºc Resolution Indication Possible (Pt input
More informationDIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS
Digital Thermometer 23 88 350 mm 3 kg (8-5/8 3-/2 3-3/4" 6.6 lbs) The Digital Thermometer has 6 ranges of temperature sensors and measuring functions of DC V and Ω. YOKOGAWA-original A/D converter (feedback
More informationPID500 FULL FEATURED PID TEMPERATURE CONTROLLERS
PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS DESCRIPTION FEATURES * Compact Size: 1/16 DIN * Dual LED displays for simultaneous indication of process temperature and set point (Lower display selectable
More informationDIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES
Digital Thermometer High-Accuracy Reference Junction Compensation: Compensation accuracy (±0.2 C) Input terminals are provided on both front and rear panels, and an input site is switch selectable. The
More informationIndustrial Modbus I/O Modules
Industrial Modbus I/O Modules Modbus I/O Modules Introduction & Features Digital Input / Output Modules Analog Input / Output Modules Modbus I/O Modules The Best Choice For Your SCADA Applications Introduction
More informationGeneral Specifications
General Specifications µrs800 Recorders GS0H0B0-00E µrs800 recorders are compact recorder with 80mm recording width, available as standard in,, 3, -pen, and 6,, 8, -point dot-printing models. These recorders
More informationBH Series 180mm CHART PEN-PRINTING TYPE HYBRID RECORDER
BH Series 180mm CHART PEN-PRINTING TYPE HYBRID RECORDER MODEL BH The BH series 180mm-chart pen-writing hybrid recorder can easily be operated in the same wayas in operating an analog recorder. It is provided
More informationUser s Manual. Model US1000 Digital Indicating Controller Functions. IM 5D1A01-02E 2nd Edition IM 5D1A01-02E
User s Manual Model US1000 Digital Indicating Controller Functions 2nd Edition Introduction This instruction manual describes the functions of the US1000 Digital Indicating Controller in detail. Read
More informationSR100 (Multi-point Type)
No. CP-SS-1890E SR100 (Multi-point Type) Hybrid Recorder Overview The SR100 Hybrid Recorder is a 6-point recorder with an LCD digital display for easy reading of measured values. This recorder has three
More informationBasic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)
Module type High-speed Digital ler SRX SRX General Description The SRX is a module type digital controller with a super high speed sampling of control updating cycle time of ms (0.0 sec). Dual loop control
More informationMulti-point Temperature Controller
Multi-point Temperature Controller Controls Up to Eight Zones, Built-in DeviceNet Communications Applications include plastic injection and extrusion machines, and continuous temperature control processes
More informationTemperature Controller
Temperature Controller 1/8 IN - 48 x 96mm Platinum Series X400 Line Cost Effective Solutions This 48x96mm size controller of the Platinum Series, provides a high degree of functionality and reliability
More informationMODEL: R30US4. Remote I/O R30 Series
Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable
More informationMODEL: M6SXU MODEL: M6SXU [1][2] [3][4]
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)
More informationPROGRAMMABLE CONTROLLER
Shimaden, Temperature and Humidity Control Specialists C %RH Series FP2 PROGRAMMABLE CONTROLLER approved UL applied BASIC FEATURES 2-channel controller (Basic type: 1-channel controller) Independent 2-loop
More informationPROGRAM CONTROLLER OUTLINE
Specifications Sheet No.SPEC-1232E (1st Edition) EC1200A PROGRAM CONTROLLER OUTLINE The EC1200 can, totally and with high precision, control and monitor such factors as temperature, temperature balance
More informationRamp/Soak Temperature Controller REX-P250
EX-P0 General The EX-P0 is a high performance ramp/soak controller with a storage capacity of segments in patterns. Each pattern consists of up to segments and patterns can be linked for maximum pattern
More informationSPECIFICATIONS Digital Indicator 1. General
SPECIFICATIS Digital Indicator 1. General The instrument is a digital indicator for the purpose of instrumentation, and suitable for the application in hopper, tank scale, and so on. 2. Specifications
More informationindicate that the contacts are available. How to Install CAUTION Panel
s Manual IM DCE This manual describes installation, wiring, and other tasks required to make the controller ready f operation.. Safety Precautions. Model and Suffix Codes. How to Install How to Connect
More informationGeneral Specifications
General Specifications GS 05P01D3101EN 35A, 32A Digital Indicating Controller (Panel Mounting Type) Functional Enhancement Overview The 35A and 32A digital indicating controllers employ an easytoread,
More informationGeneral Specifications
General Specifications µrs000 Recorders µrs000 recorders are compact recorder with 00mm recording width, available as standard in -pen, 2-pen, 3- pen, 4-pen, and 6-point dot-printing models. These recorders
More informationSHIMADEN DIGITAL CONTROLLER
Shimaden, Temperature and Humidity Control Specialists C %RH Series SR9 SHIMADEN DIGITAL CONTROLLER ASIC FEATURES Multi-input and multi-range performance Large mm bright display (SR9) Readable from a distance
More informationGeneral Specifications
General Specifications GS 05P01D3181EN 35A/RSP, 32A/RSP Digital Indicating Controller (with Nonisolated Remote Input) Functional Enhancement Overview The 35A/RSP and 32A/RSP are singleloop controller with
More informationGeneral Specifications
General Specifications UP35A Program Controller [Style: S9] Overview The UP35A program controller employs an easy-toread, 14-segment large color LCD display, along with navigation keys, thus greatly increasing
More informationModel Number Structure
Digital Controller CSM DS_E_3_1 Advanced Digital Controllers Ideal for Worldwide Use Modular structure High-accuracy: 100 ms sampling (for analog input) Auto-tuning and fuzzy self-tuning Conforms to international
More informationREX-F400 REX-F700 REX-F900
REX-F REX-F REX-F General The F series controller provides precise control with high accuracy of.% full scale and short sampling time of. second. ewly developed and unique logic, rilliant PID control and
More informationGeneral Specifications
General Specifications GS J0U0-0E Model MU Universal Temperature Converter (Free Range Type) General The MU is a plug-in type universal temperature converter that converts input signal (thermocouple, RTD
More informationK3P ENG.qxd 23/10/ Pagina 1
K3P ENG.qxd 23/10/2003 12.30 Pagina 1 - CLEAR PROGRAM STATUS DISPLAY - DIRECT PROGRAM PARAMETER ADJUSTMENT - 8 INDEPENDENT PROGRAMS - 10 SEGMENTS FOR EACH PROGRAM - "SET - POINT TRACKING " AND "GUARANTEED
More informationGeneral Specifications
General Specifications GS 04L53B01-01EN GX90XA/GX90XD GX90YD/GX90WD I/O Modules OVERVIEW I/O modules are connected to the GX/GP, Expandable I/O unit, GM main unit, and GM sub unit. A module type is four
More information7SD/7SH/7SM Temperature Controllers
7SD/7SH/7SM Temperature ADVANTAGE EZ Series 7SD, 7SH, 7SM 1/16 DIN Temperature 3Digit LED Display Thermocouple and RTD Input Autotuning NEMA 4X Field onfigurable 100 to 40 Vac Switching Power Supply Programmable
More informationP5201 Universal Programmable Transmitters with Galvanic Isolation