CHAPMAN GRIFFIN LANIER SUSSENBACH ARCHITECTS, INC. ARCHITECT S ADDENDUM NO. 06

Similar documents
Bidders and Others to Whom Bidding Documents have been issued by the Architect and/or CM.

ADDENDUM #1. April 29, 2009

HOENER ASSOCIATES INC. ARCHITECTS

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

Introducing AJSTM INSTALLATION GUIDE USA. 8 th Edition USA

ADDENDUM NOTICE INTERIOR RENOVATIONS AT THE BATHURST CLARK RESOURCE LIBRARY, 900 CLARK AVENUE WEST, VAUGHAN, ON

ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)

Single-Family Dwelling Submittal Requirements

COLD-FORMED METAL FRAMING INSPECTION REPORT SUMMARY

Garage Design Guide. October 2018

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

This specification describes the minimum requirements for structural steel drawings.

GLOSSARY OF TERMS SECTION 8

Typical Deck Details

Typical Deck Details

NORMAL WEIGHT CONCRETE TOTAL-LEWIS-DECK GYPSUM BOARD 2 OR 3-PLY COMPOSITE TOTALJOIST TOP CHORD CONNECTION

To the Drawings and/or Specifications for. Board of Education of Harford County Lancaster, PA 17603

Montclair, NJ ADDENDUM NO. 1 Issue Date: May 15, 2017

3. Are component and cladding design pressures consistent with ASCE 7 for the wind speed and exposure category (ASCE 7 Fig. 6-3)?

GlasRoc Sheathing Type X

3.1 General Provisions

REINFORCEMENT DESIGN FOR METAL BUILDING SYSTEMS

STANDARD MSGDET4AC: NOTES TO DESIGNER

FIRE STATION NO TH STREET NORTH ST. PETERSBURG, FL M-1 SCOPE OF WORK SYMBOL DESCRIPTION SYMBOL DESCRIPTION HVAC SYMBOL LEGEND

RENOVATION OF THE FARMERS MARKET Reference Number:

Acceptable Standards of Domestic Construction

REQUEST FOR INFORMATION

Sections & Details VOCABULARY

November 16, 2017 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA. Y CH / Addendum #6 SHERRY DRIVE BRIDGE REPLACEMENT

Suggested Reinforcement Detailing Practices Based on comments from R&D and ES ESS Committees

Use the Design Properties (100% Load Duration) Table from Page 3 for questions 1-7

VERSA-LAM BCI INSTALLATION GUIDE LIMIT STATES DESIGN CANADA

IRC 2015 Code Compliant Wood Framed Residential Details. Incorrect Installations of Connectors with code references and remedies, discussion.

Project Booklet. Structural Drafting with AutoCAD

ADDENDUM NO. 2. Furnace Bridge - Installation. Essex County, NY. July 29, 2015

PANEL NOTATION (3) D4 D3 D2 D3X2 SHEATHING THICKNESS (IN.) D " NAILS/ SPACING " o.c. SILL BOLT SPACING 1 2 " 36" O.C. 1 2 " Ø

Definitions and Design Considerations... W-CR-2

APPLICATION FOR A BUILDING PERMIT

Central Office Grayson County Schools Leitchfield, Kentucky BG #13-089

Site Preparation Information for:

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO

ADDENDUM NO. 4 November 15, Page 1

Standard Signs Manual

Total precast solution for large stadium projects meet tight schedule

HIA AIR CARGO HAMILTON ADDENDUM #3. Addendum No. A03 (Architectural) o Text 1 page o SK-10a o SK-10b o SK-11

Sutton Screened in Awning / Porch

IRC 2012 Code Compliant Wood Framed Residential details. Miss Installed Connectors with code references and remedies, discussion.

1.1 RELATED DOCUMENTS

AASHTO/NSBA Steel Bridge Collaboration G Design Drawing Presentation Guidelines. AASHTO/NSBA Steel Bridge Collaboration

HOME STRENGTHENING GUIDE HOW TO ECONOMICALLY STRENGTHEN YOUR HOUSE AGAINST EARTHQUAKES AND HURRICANES

Carpentry/Carpenter CIP Task Grid

T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY


1. Show the following information with additional information necessary to indicate shop compliance with the requirements of this section.

STRUCTURAL WOOD DETAILING IN CAD FORMAT

BUILDING PLANS. BUILDING DEPARTMENT

HAYES VALLEY PLAYGROUND AND CLUBHOUSE PROJECT NO.: SAN FRANCISCO PARKS AND RECREATIONS SAN FRANCISCO, CA

3 DATE ISSUE R# Forefront Dermatology. CONFLUENCE DESIGN GROUP #2 Daniel Drive O'Fallon, MO ph: St. Peters, Missouri 63376

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE

S001 LOWER LEVEL ISO SECOND FLOOR ISO S001 FULL ISO FIRST FLOOR ISO. O="Katahdin Engineering, LLC",

Listed below are the competencies required and examples from the aforementioned job:

Typical Deck Details Based on the City of Nixa Residential Deck Ordinance

OHIO DEPARTMENT OF TRANSPORTATION CENTRAL OFFICE, 1980 W. BROAD ST., COLUMBUS, OHIO

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

ADDENDUM NO. 2. Germania Club Renovation Phase 2. Saginaw County Community Mental Health Authority WILLIAM A. KIBBE & ASSOCIATES, INC.

AUXILIARY FRAMING AND ACCESSORIES

SUPERIOR COURT OF CALIFORNIA NORTH BUTTE COUNTY COURTHOUSE JBCP201205BR ADDENDUM NO. 5. February 25, 2013

10930 W. Sam Houston Parkway N., Suite 900

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

Stantec Architecture Inc South Flores Street Suite 201 San Antonio TX Tel: (210) Fax: (210)

BUILDING PLANS. BUILDING INSPECTIONS DEPARTMENT

CONSTRUCTION / HOUSING

Strong, lightweight composite structural I -Beam.

Sections & Details. WOOD SILL and FLOOR CONSTRUCTION NOTES

Deck Evaluation Checklist

MTJ Outdoor Baggage Claim

Residential Construction Checklist Single and Two Family Construction

Construction Tolerances - The following tolerances apply to cast-in-place structures:

Marshall Truck Station Laboratory Addition Project No. TZ MnDOT

Storefront Installation Guide INSTALLATION INSTRUCTIONS

Drywall, Wood and Truss Uplift

MPA Project No. M495-C1 Refrigerated Container Storage Improvements Project Location: Conley Terminal, Boston, MA

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

1.01 NOTICE TO BIDDERS

PLAN CEILING FRAMING PLAN CEILING JOIST SCHEDULE. Tenant Improvements. UNLV Police Station Maryland Parkway.

Products for fixing to Steelwork and Decking

PART II ENGINEERED BASIS OF RIDGE AND EAVE VENT DETAILS

DOCUMENT SUBMITTAL REQUIREMENTS FOR AN ALTERATION OR ADDITION TO AN EXISTING SINGLE-FAMILY DWELLING OR MULTI-FAMILY DWELLING

Glulam Connection Details

Vertical Offset Base and Safety Rail System Installation Instructions

602.4, TABLE 602.4, , , , , , , , , TABLE

TYPICAL PATIO COVERS. OWNER: ADDRESS: PHONE:

LP SolidStart LSL. LP SolidStart LSL Prescriptive Roof Framing Technical Guide 2500F b-1.75e, 2360F b -1.55E and 1730F b -1.

Nailed Structural-Use Panel and Lumber Beams

ESR-1254 * DELETED BY CITY OF LOS ANGELES. Reissued April 1, 2006 This report is subject to re-examination in one year.

Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016

The following information supplements and/or supersedes the bid documents issued on July 10, 2017.

14000 Series. Fabrication and Installation Instructions

Wood Connections. Concepts of Well Designed Connections

ASSEMBLY INSTRUCTIONS FOR SOFTOP SHADE COVER

Transcription:

CGLS A R C H I T E C T S CHAPMAN GRIFFIN LANIER SUSSENBACH ARCHITECTS, INC. 2500 Cumberland Parkway Suite 350 Atlanta, Georgia 30339 404.733.5493 (voice) 404.733.6804 (fax) www.cglsarchitects.com ARCHITECT S ADDENDUM NO. 06 TO: ALL HOLDERS OF PROPOSAL DOCUMENTS PROJECT: WALTON HIGH SCHOOL REPLACEMENT SCHOOL COMPLETION STAGE 2, PHASE 2 - PERFORMING ARTS AND ATHLECTIC SPACES 1590 BILL MURDOCK ROAD MARIETTA, GEORGIA 30062 OWNER: COBB COUNTY SCHOOL DISTRICT 440 GLOVER STREET MARIETTA, GEORGIA, 30060 ARCHITECT: CHAPMAN GRIFFIN LANIER SUSSENBACH ARCHITECTS, INC. 2500 CUMBERLAND PARKWAY SUITE 350 ATLANTA, GEORGIA 30339 DATE: JANUARY 31, 2018 The items listed on the attached pages take precedence over referenced portions of Contract Documents for the project and, in executing a contract, shall become a part thereof. Where any item called for in the Contract Documents is supplemented hereby, the original requirements shall remain in effect. All supplemental conditions shall be considered as added thereto. Where any original item is amended, voided, or superseded hereby, the provisions of such items not so specifically amended, voided, or superseded shall remain in effect. THIS ADDENDUM IS ISSUED TO PROVIDE THE STRUCTURAL SHEETS LISTED IN ADDENDUM #5 AS (CLARIFICATION/COORDINATION). ONE ADDITIONAL CHANGE IS LISTED UNDER PART 1. PART 1 - CHANGES TO THE DRAWINGS 1-1 Sheet A-4.31 CANOPY DETIALS: Sheet reissued in its entirety. A. Revise 2/A-4.31 to change the canopy depth as indicated. PART 2 - CHANGES TO THE SPECIFICATIONS PART 3 SUBSTITUTION REQUEST RESPONSES PART 4 QUESTIONS FROM CONTRACTORS

CGLS ARCHITECTS, INC. Page 2 PART 5 CHANGES TO ADDENDA 5-1 Sheet A-4.31 CANOPY DETIALS: Sheet reissued in its entirety. B. Revise 4/A-4.31 to change the canopy depth from 4-0 to 5-8. 5-2 Sheet A-6.22 WALL SECTIONS: Sheet reissued in its entirety. A. 3/A-6.22 provide soffit vent full perimeter of ceiling at loading dock. 5-3 Sheet S-2.11 LEVEL 200 FOUNDATION PLAN - PART 1: Sheet reissued in its entirety. A. Changed footing size at A.P/5 & A.J/5 to F10. 5-4 Sheet S-2.12 LEVEL 200 FOUNDATION PLAN - PART 2: Sheet reissued in its entirety. A. Changed pier type at grid intersection A.O/38 to pier type P3. B. Changed footing size at G/45 to F9. C. Changed footing sizes at A.J/5, A.O/43.1, L/45, & N/45 to F10. D. Changed footing sizes at I/11.2, I/39.7, A.N/45 & A.G/43.1 to F7. E. Changed footing size at S/45 to F11. F. Added Grids 16.3 & 34.8 to clarify location of columns K/16.3 & K/34.8 (see S-2.22). 5-5 Sheet S-2.13 LEVEL 200 FOUNDATION PLAN - PART 3: Sheet reissued in its entirety. A. Changed pier type at grid intersection A.O/38 to pier type P3. B. Changed footing size at B.J/13.9 & B.J/39 to F10. C. Changed footing size at B.J/22 to F8 D. Changed columns at B.J/30 & B.J/33 from HSS12x8x5/8 to HSS8x8x3/8. 5-6 Sheet S-2.14 LEVEL 200 FOUNDATION PLAN - PART 4: Sheet reissued in its entirety. A. Changed footing sizes at B.J/46 & B.B/83 to F6. B. Changed footing sizes at A.N/45 to F7. 5-7 Sheet S-2.15 LEVEL 200 FOUNDATION PLAN - PART 5: Sheet reissued in its entirety. A. Changed footing size at G/45 to F9. B. Changed footing sizes at A.O/43.1, L/45, & N/45 to F10. C. Changed footing sizes at A.N/45 & A.G/43.1 to F7. D. Changed footing size at S/45 to F11. 5-8 Sheet S-2.21 LEVEL 300 FLOOR FRAMING PLAN - PART 1: Sheet reissued in its entirety. A. Added section cut 7/S-6.14 (sim) for clarification @ edge of stair landing along grid A.J. 5-9 Sheet S-2.25 LEVEL 325 FLOOR FRAMING PLAN - PART 5: A. Added section cut 7/S-6.14 (sim) for clarification @ edge of stair floor landing along grid A.N. 5-10 Sheet S-4.14 ROOF FRAMING PLAN - PART 4: Sheet reissued in its entirety. A. Updated tube beam along Grid B.K between Grids 47-52 to HSS16x8x3/8 (LSV) & updated section at this tube beam from 1/S-7.28 to 6/S-7.28 to coordinate with Architectural.

CGLS ARCHITECTS, INC. Page 3 5-11 Sheet S-4.15 ROOF FRAMING PLAN - PART 5: Sheet reissued in its entirety. A. Added HSS6x4x1/2 (LSH) stub cantilevers at lobby roof from columns at Grid A along 58.8 & 53 to end of joist top chord extension per 4/S-7.17. 5-12 Sheet S-6.13 FLOOR FRAMING SECTIONS & DETAILS: Sheet reissued in its entirety. A. 1/S-6.13 Modified roof deck edge bent plate thickness to ½. Clarified joists shall be designed for 7.6k point load from brick veneer B. 2/S-6.13 Modified roof deck edge bent plate thickness to ½. Clarified joists shall be designed for 7.2k point load from brick veneer. 5-13 Sheet S-6.14 FLOOR FRAMING SECTIONS & DETAILS: Sheet reissued in its entirety. A. 7/S-6.14 Deleted L3x3x5/16 slab edge angle @ edge of stair landing slab. Added L4x4x3/8 x continuous with ¾ diameter expansion bolts (embed 6 ) @ 24 oc in 2 vertical slots connecting bottom of stair channel to CMU wall. B. 9/S-6.14 Removed CMU wall & T/CMU wall connection below floor beam from section. T/CMU wall stops (1) course above ceiling per Architectural. 5-14 Sheet S-6.16 FLOOR FRAMING SECTIONS & DETAILS: Sheet reissued in its entirety. A. 5/S-6.16 Updated slab edge location to 1-2 from grid A.E. & corresponding slab edge bent plate horizontal leg length to 13 ½ to coordinate with Architectural update. Modified beam web stiffener thickness to 5/16 each side. B. 7/S-6.16 Changed L8x8x1/2 continuous with ¼ stiffener plates @ 48 on center to 3/8 X 9 ½ continuous steel plate with 5/16 stiff plates @ 32 C. 8/S-6.16 Updated slab edge bent plate thickness to 3/8. Added ¼ beam web stiffener plates @ 48 oc. D. 9/S-6.16 - Changed L8x8x1/2 continuous with ¼ stiffener plates @ 48 on center to 3/8 X 9 ½ continuous steel plate with 5/16 stiff plates @ 32 on center. 5-15 Sheet S-6.17 FLOOR FRAMING SECTIONS & DETAILS: Sheet reissued in its entirety. A. 3/S-6.17 & 4/S-6.17 - Deleted 3/8 X7 X6 (LLH) x continuous veneer relief bent plate & weldable bars at slab edge. 5-16 Sheet S-7.13 ROOF FRAMING SECTIONS & DETAILS: Sheet reissued in its entirety. A. 2/S-7.13 Removed weld size for tube beam to embed plate connection to be coordinated by steel fabricator with tube beam radius. 5-17 Sheet S-7.15 ROOF FRAMING SECTIONS & DETAILS: Sheet reissued in its entirety. A. 3/S-7.15 Noted reactions for joist design. 5-18 Sheet S-7.16 ROOF FRAMING SECTIONS & DETAILS: Sheet reissued in its entirety. A. 3/S-7.16 Clarified spacing of expansion anchors in deck edge bent plate to be at 24 oc. Modified roof deck edge bent plate thickness to ½. Corrected veneer load on joist to 7.6k. B. 4/S-7.16 Noted reactions for joist design. 5-19 Sheet S-7.17 ROOF FRAMING SECTIONS & DETAILS: Sheet reissued in its entirety. A. 4/S-7.17 Noted reactions for joist design.

CGLS ARCHITECTS, INC. Page 4 5-20 Sheet S-7.18 ROOF FRAMING SECTIONS & DETAILS: Sheet reissued in its entirety. A. 1/S-7.18 Noted reactions for joist design. 5-21 Sheet S-7.19 ROOF FRAMING SECTIONS & DETAILS: Sheet reissued in its entirety. A. 1/S-7.19 Noted for GC to provide steel shims as needed on top of steel truss for deck bearing to accommodate differential deflection between truss and adjacent joist. Added note for cross bridging not to be installed in end bay of Gym roof between steel joist & steel truss. 5-22 Sheet S-7.20 ROOF FRAMING SECTIONS & DETAILS: Sheet reissued in its entirety. A. 1/S-7.20 1. Updated T/CMU wall bent plate connection size from bent plate 3/8 x 17 x 8 (LLV) to bent plate 3/8 X 17 X 5 (LLV). 2. Updated F/CFSF stud relative to centerline of steel beam. 3. Added CFSF clip connection from high deck edge bent plate to parapet CFSF. 4. Added plf load for steel joist to be designed for. 5. Added bent plate 3/8 x 10 x 10 x 12 long @ 32 on center with ¾ diameter expansion anchors @ 32 on center at bottom of steel joist connection to CMU wall. 6. Added 12 depressed web block with (2) - #5 continuous at new bottom of steel joist connection to CMU wall. 5-23 Sheet S-7.21 ROOF FRAMING SECTIONS & DETAILS: Sheet reissued in its entirety. A. 3/S-7.22 - Modified roof deck edge bent plate to 11 x6 x½ (LLH). 5-24 Sheet S-7.22 ROOF FRAMING SECTIONS & DETAILS: Sheet reissued in its entirety. A. 1/S-7.22 - Modified roof deck edge bent plate to 11 x6 x½ (LLH). B. 2/S-7.22 1. Updated T/CMU wall bent plate connection size from bent plate 3/8 x 17 x 8 (LLV) to bent plate 3/8 X 17 X 5 (LLV). 2. Updated F/CFSF stud relative to centerline of steel beam. 3. Added CFSF clip connection from high deck edge bent plate to parapet CFSF. 4. Added plf load for steel joist to be designed for. 5. Added bent plate 3/8 x 10 x 10 x 12 long @ 32 on center with ¾ diameter expansion anchors @ 32 on center at bottom of steel joist connection to CMU wall. 6. Added 12 depressed web block with (2) - #5 continuous at new bottom of steel joist connection to CMU wall. 5-25 Sheet S-7.27 ROOF FRAMING SECTIONS & DETAILS: Sheet reissued in its entirety. A. 1/S-7.27 1. Updated Tube beam width from 12 wide to 8 wide. 2. Clarified dimension from centerline of tube to grid B.J. 3. Added 4 CMU grouted solid at interior face of tube beam. 5-26 Sheet S-7.28 ROOF FRAMING SECTIONS & DETAILS: Sheet reissued in its entirety. A. 4/S-7.28 - Modified roof deck edge bent plate thickness to ½.

CGLS ARCHITECTS, INC. Page 5 B. Added section 6/S-7.28, which revises 1/S-7.28 at Grid B.K between Grids 47-52 (sheet S- 4.14) for tube beam update from 12 wide to 8 wide with 4 CMU grouted solid @ interior face of tube beam. 5-27 Sheet S-7.29 ROOF FRAMING SECTIONS & DETAILS: Sheet reissued in its entirety. A. 3/S-7.29 Noted reactions for joist design. Updated HSS on top of joist to HSS4x4x5/16. END OF ADDENDUM NO. SIX