Addendum No. 1 page 1

Similar documents
ADDENDUM NO. 4 November 15, Page 1

05BDB ADDENDUM 002. Thomas W. Wathen Business Division Building Renovation GENERAL ITEMS:

ADDENDUM THREE SPECIFICATIONS. Vincennes University Renovations of the Curtis G. Shake Learning Resources Center

MSU Barnard Hall 105 Cleanroom Installation PPA # Page 1

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

Bid No. B14-02 Building 100 HVAC Improvements

BIRMINGHAM CITY SCHOOLS (BCS) OPERATIONAL CENTER COMPLEX: BID PACKAGE D

TELEPHONE: (215) Addendum No Cooling Plant Replacement SDP Contracts No. B-080C, B-081C and B-082 of 2017/18

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

PROJECT: ARCHITECT S SUPPLEMENTAL INSTRUCTION NO.: 002 Marquis Newberg 3914 Hayes Street Newberg, Oregon OWNER ARCHITECT X CONSULTANT

Lincoln County Tax Appraisal Office Project No. RFB

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

TO WHOM IT MAY CONCERN:

State College of Florida, Manatee-Sarasota

Addendum No. 4 page 1

Industrial Pipe Marking

U of I Facilities Standards Updates for 2017

Answer: Only to ChurchWoods, LLC.

MPA Project No. M495-C1 Refrigerated Container Storage Improvements Project Location: Conley Terminal, Boston, MA

SECTION MECHANICAL IDENTIFICATION

1.1 The Bid Date has changed to October 4, The time and place will remain the same.

Facility Services Subgroup Preface for Divisions 21` through 28

9. Pay for the power consumed until the project has been accepted as substantially complete.

ADDENDUM #1. April 29, 2009

City of Thousand Oaks

ADDENDUM NO: 1 IFB/RFP No: NKU Commodity: Kentucky Hall Renovation Date: 12/7/2017 Due Date: 12/18/2017

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

SECTION MECHANICAL IDENTIFICATION

SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15.

PROCUREMENT SERVICES th St, SW Calgary, AB T2R 0L4 Telephone: (403) Fax: (403)

Marshall Truck Station Laboratory Addition Project No. TZ MnDOT

SECTION MECHANICAL IDENTIFICATION

ADDENDUM #2 September 12, 2018

MPA Project No. M495-C1 Refrigerated Container Storage Improvements Project Location: Conley Terminal, Boston, MA

State College Area School District

OCPS Submittal Register for Product Data and Shop Drawing Reviews

Stantec Architecture Inc South Flores Street Suite 201 San Antonio TX Tel: (210) Fax: (210)

ADDENDUM NO. 3, March 14, 2017 A.B.C. No

ADDENDUM NO. 4 TO THE CONTRACT DOCUMENTS SUPPLEMENTAL INFORMATION

ADDENDUM NO. TWO. To the Plans and Specifications for: PALM COAST READINESS CENTER PALM COAST, FL For FLORIDA DEPT. OF MILITARY AFFAIRS

ADDENDA ADDENDUM NO. 1 DATE: MARCH 1, 2016

Address: South Elgin, IL Phone: ( ) - Fax: ( ) - Cell: ( ) - Contractor Type: Phone: ( ) - Fax: ( ) - Cell: ( ) - Contact Type:

ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO.

UNION COUNTY ENGINEER DIVISION OF BUILDING REGULATIONS

Cone HVAC Modernization. Thursday, September 1, 2016 Pre Proposal Conference

M1.0 MECHNANICAL FLOOR PLAN

PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES

SECTION PROJECT COORDINATION VIA BIM

INSTALLATION INSTRUCTIONS At Air-Handler Location

Montclair, NJ ADDENDUM NO. 1 Issue Date: May 15, 2017

Residential Construction Checklist Single and Two Family Construction

Addition and Renovations to Upper Bucks County Technical School

City of Lompoc Building & Safety Services Section 100 Civic Center Plaza Lompoc, CA Phone: Fax:

Addendum No. 1 page 1

ELECTRICAL GENERAL DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Electrical/Telecommunications Design

Design Deliverables. Summary. A. Expectations for Design Deliverables:

2. Electrical rooms shall be centrally located and stacked so that feeder conduits and bus duct are run as straight and short as possible.

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)

ADDENDUM NO. 2. The Bid Opening has not changed it remains December 8, 2016 AT 1:30 P.M.

Procurement Department Bid Office Customer Center 1 st Floor, Room W. Church Street Jacksonville, Florida 32202

HAYES VALLEY PLAYGROUND AND CLUBHOUSE PROJECT NO.: SAN FRANCISCO PARKS AND RECREATIONS SAN FRANCISCO, CA

Quality Control Checklist - Design Drawings

C0330, C0530, C0630, C0830, C1030 Service Parts

Spec Section: , Complete Elec, Comm, and Fire Alarm , Complete Elec, Comm, and Fire Alarm Data Sheets RAN/GCAN

HAMMEL ASSOCIATES ARCHITECTS, LLC 2 5 E A S T G R A N T S T R E E T, S U I T E L A N C A S T E R, P E N N S Y L V A N I A

ADDENDUM NOTICE INTERIOR RENOVATIONS AT THE BATHURST CLARK RESOURCE LIBRARY, 900 CLARK AVENUE WEST, VAUGHAN, ON

Notre Dame High Addition/Renovation Addendum 3 Page 1

SECTION CLOSEOUT SUBMITTALS SECTION CLOSEOUT SUBMITTALS

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEM(S) FOR STREETLIGHTS. 1 Definitions. 2 Scope of Work. 3 Extent of Work

03/7/12 Issuance UTD Section Page 1 of 5 Electrical General

Snohomish County Courthouse Renovation + Addition COUNCIL PRESENTATION 6 MARCH 2017

Zone Control Unit (ZCU) VAV Turnkey Solution

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

SECTION BASIC MATERIALS AND METHODS. A. The requirements of the General Conditions and Supplementary Conditions apply to all Work herein.

Introduction. Classifications of piping: Industrial. Residential (i.e., plumbing) Carries liquids and gases used in the manufacture of products

Residential Room Addition / Remodel Submittal Requirement Checklist

4. Special Systems Design: including Fire Alarm and Security. C. Electrical and Telecommunications Ductbanks: Refer to Section 16118

ADDENDUM 4 BID OPPORTUNITY NO

Introduction to BAS Technology

PRESS RELEASE. Let s create your success! with GEA at Chillventa 2016

NORTHWEST FLORIDA STATE COLLEGE MONUMENT SIGNS WITH LED DISPLAYS

FIRE STATION NO TH STREET NORTH ST. PETERSBURG, FL M-1 SCOPE OF WORK SYMBOL DESCRIPTION SYMBOL DESCRIPTION HVAC SYMBOL LEGEND

Anticipated schedule, Page 2. Change the Contract Term from 635 Days to be 1,127 Days.

ADDENDUM No. 4 Page 1 of 8 (includes attachment)

Zone Control Unit (ZCU) Solution

MONROE COUNTY BOARD OF EDUCATION ABC PROJECT NO ADDENDUM NUMBER 4. Thursday, May 8, 2014


Project NO Date: March 16, ADDENDUM NO. 3 GRAYSON PARK RENOVATIONS Page 1 of 1 DEPT. OF PLANNING, ENG & PERMITS GENERAL

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

B. Manufacturers: Square-D, G.E. or Westinghosue.

Digitally signed by Anne Prudhel Contact Info: Carollo Engineers, Inc. Date: :06:03-07'00'

Addendum Number: 1 WT White HS Additions and Renovations, Dallas ISD

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

SECTION PANELBOARDS

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO

Company. Signed: Date:

Transcription:

Addendum No. 1 page 1 Project: Proj. No: 1634.02 Scottsburg High School HVAC Renovation 2017 Scott County School District 2 Scottsburg, Indiana Date: November 22, 2016 This addendum is a part of the bid documents. Acknowledge receipt on the Proposal Form. General 1. A Pre-Bid Conference is scheduled for Wednesday, November 30 at 10:00 AM. Please sign in at the main office with your driver s license and you will be directed where to go. 2. As a reminder, the State of Indiana has repealed the Wage Scale. The requirements for wage rates are not required and a Wage Scale is not included. General Questions and Answers 1. Q: Condensate piping is shown but it does not show where it goes to. A: Take condensate from UVs as shown in Detail #9, M501. Condensate main shall terminate into vents as shown on piping plan drawings M200 & M201. 2. Q: Note in middle of M200 refers to coil connection as shown on AD-2/3. Where is AD-2/3? A: AD-2/3 is a typo and should read AC-2/3. See coil connection diagrams on M500, Existing AC-2 & AC-3 Coil Connection. 3. Q: Is an insulated panel specified for the blank off? A: Instead of an insulated panel, the entire duct stub is to be insulated IAW Detail 11, M501. Contractor may shorten length of duct stub as short as practical to minimize sealing/insulation requirements. Specifications 1. Section 15620 1 1.02.A, revise to read: This Section includes air cooled, rotary or scroll compressor water chillers with remote condenser. 2. Section 15620 2 2.02.A, revise to read: Description: Hermetic or serviceable hermetic scroll or screw compressor, lubrication system, crankcase heater, suction and discharge line service valves, mounted on vibration isolators. 3. Section 15620 5 2.08.A, revise to read: The chiller shall have spring isolation; condensers shall be mounted as described on plans. Chiller shall have direct isolation (no base) and the following vibration isolators: 1. Vibration Isolators: Restrained-spring type, galvanized or epoxy coated for exterior installation with minimum deflection of 0.75 inch (19 mm). 4. Section 15765-2 2.01.A, add 9 and revise to read: JCI/Envirotech. 5. Section 15780 3 2.02.D.2, revise to read: Thickness, 1 minimum. Registered Architect: Indiana #19900007 Kentucky #5066 NCARB #51592 American Institute of Architects #30121121 Construction Specifications Institute #1194282 Registered Interior Designer: Indiana #00411 Direct: 812. 913.4605 Email: jamie.lake@koverthawkins.com

Addendum No. 1 page 2 Drawings 1. M100, Condenser Locations (also applies to M401): In lieu of routing the refrigerant lines underground according to Detail 12, M501, the lines may be routed above ground using MAPA or eqv. If pipes are to be routed above ground, the areaway shall be enclosed with fence. Drop refrigerant lines directly into grating from above, cut grating as req d. If fence comes into contact with existing gas meter fencing, ensure door swing and access is not covered up. Fence shall extend to all edges to prevent unauthorized access. Leave 4 clearance for existing condensing unit associated with walk in cooler/freezer. Mulch areas may be demolished as req d. Plant grass or gravel as described in plans & plan details. 2. M400, Enlarged Office Area Mechanical Plan, Alternate No. 2 Work: As part of Alternate No. 2: Electric wall heaters shall be added to Boys and Girls RR as shown on attached sketch M4. Ensure mounting is clear of water closet door opening. Heaters are to be provided by M.C. E.C. to provide: Wire & conduit: 2-#12 CU, 1-#12 GND ¾ C. Breaker: 1 pole, 30A breaker. Panel designation: HC-35, HC-36. 3. M501, Detail 9: Change condensate pump model to: Little Giant VCMA-20ULS. 15 head @ 20 GPH. Pump shall be provided by UV MFGR. UV MFGR shall wire pump from internal contacts in UV. MFGR shall also wire pump to shut fan off in case of failure. 4. M600: The following sequences included as attachments in text format. It is intended that the text format is a duplication of the graphical format sequences shown on M600. Contractor shall notify engineer via email if any discrepancies are found between text sequences and graphical sequences. Direct all inquiries to asteiner@sims-durkin.com. Any conceptual changes between the graphical sequences and the text sequences are bubbled. Note that these sequences do not overwrite those issued on the plans, except as bubbled: SINGLE ZONE VAV AHUS, Sketch M1. MULTI ZONE VAV AHUS, Sketch M2. UV SEQUENCES, Sketch M3. 5. M700: AHUS-H1, 2, 3, & 9 are not part of the base bid. See plans for alternate numbers for these AHUs. Prepared by, James C. Lake, AIA Principal enclosed: file: (3) M2, M3, M4 1634.02/E-1 End of Addendum No. 1 Registered Architect: Indiana #19900007 Kentucky #5066 NCARB #51592 American Institute of Architects #30121121 Construction Specifications Institute #1194282 Registered Interior Designer: Indiana #00411 Direct: 812. 913.4605 Email: jamie.lake@koverthawkins.com