MODEL: JB2. Plug-in Signal Conditioners M-UNIT

Similar documents
MODEL: KS. Plug-in Signal Conditioners K-UNIT

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: W2TS. Mini-MW Series

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2DYS SEN TRONIC AG

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: M1EXT. with Display M1E Series

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.

MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MODEL: R30US4. Remote I/O R30 Series

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection

JPQ2 PULSE ACCUMULATOR

[3] MOUNTING DIRECTION

MODEL: DAST-20. Telemetering System

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: 48NDVD. Bargraph Indicators 48N Series

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: 48NDV. Bargraph Indicators 48N Series

JTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION

MODEL: DLS. Telemetering System

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2]

MODEL: WL40MW1F. Wireless I/O WL40F Series

WJM POTENTIOMETER TRANSMITTER BEFORE USE... COMPONENT IDENTIFICATION POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (field-programmable)

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: MRP6. Final Control Elements

MODEL: M2CEC MODEL: M2CEC-[1][2][3]-[4][5]

General Specifications

MODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: M5CTC. [4] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) DC Power R: 24 V DC MODEL: M5CTC [1][2][3] [4][5]

Conductivity Analyzer

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

PLUG-IN TRANSDUCER SOFT SPEC. TYPE C SERIES

General Specifications

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements

Fuzzy Temperature Controllers E5AF

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

MODEL: TC10EM. Temperature Controller TC10 Series

PPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation)

General Specifications

n FRONT PANEL CONFIGURATIONS

Solid-State Digital Counter H7AN


High Performance Process & Temperature Controllers

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

Excellent low-cost Process & Temperature Controllers

Adjustable Digital Process Instrument MDK480

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

PA-850 PRESSURE TRANSDUCERS WITH AMP. PA R - N R2 FEATURES MODEL NUMBER DESIGNATION

General Specifications

Economical Digital Indicators For Process and Electrical Measurement

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

PROGRAMMABLE CONTROLLER

8900 Multi-Parameter Controller

TORKEL 900-series Battery Load Unit

General Specifications

DIS-5010A, DIA-512A. Data Acquisition System for Crash Test AUTOMOTIVE TEST EQUIPMENT

TORKEL 900-series Battery Load Unit

General Specifications

PROCESS & TEMPERATURE CONTROLLERS

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail

CT325 Miniature DC Temperature Controller

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature

Model Sono-Trak Transit Time

P5201 Universal Programmable Transmitters with Galvanic Isolation

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

+GF+ SIGNET Temperature Transmitter Instructions

DIGEM f 96 x 48 EK. Applications. Description

HA400 HA900 HA401 HA901

User s Manual. Model MXS Universal Computing Unit (1-input, Isolated 2-output Type) MODEL AND SUFFIX CODES

Energy Management Modular Smart Power Transducer Type SPT-90

General Specifications

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

Low Profile. 3 Year Warranty

Converter. Specifications/Instructions. General. Features. Specifications. Dimensions AB-6484

General Specifications

MODEL AT-10 ANALOG TRANSMITTER

Transcription:

Plug-in Signal Conditioners M-UNIT ANALOG BACK STATION Functions & Features Enables manual loading providing hold/increase/ decrease signals to a device controlled by PID controller When the PID controller fails, the JB2 output goes back the preset time period and holds the cascade control signal of that moment (Retroactive function) Cascade control loop does not open even when the JB2 itself fails Manual control output transits smoothly to the cascade control mode in the preset response time (Sliding-back function) Isolated re-transmitted output Parameters set via hand-held programmer PU-2x Can be driven on battery power supply (35 V DC max.) Typical Applications Backup hold/manual loading for the DCS or computer control output failure Manual control mode 1 Man/cas transition response 0.00 Up/down response mode 0 Up/down response time 10.00 High/low alarm mode at cas control 0 Low alarm setpoint -25.00 High alarm setpoint 125.00 Retroactive time period 0.0 Initial manual control value 0.00 Output after power recovery in manual control mode Output value after power recovery 0 CAS INPUT A: 4 20 ma DC A: 4 20 ma DC -25.00 72 (2.83) 80 (3.15) RE-TRANSMITTED OUTPUT A: 4 20 ma DC (Load resistance 350 Ω max.) 136 (5.35) mm (inch) POWER INPUT DC Power R1: 15 35 V DC (Operational voltage range 15 35 V, ripple 10 %p-p max.) MODEL: JB2AAAR1/A[1] ORDERING INFORMATION Code number: JB2-AAA-R1/A[1] Specify a code from below for [1]. (e.g. JB2-AAA-R1/A/Q) Use Ordering Information Sheet (No. ESU-2642) to specify details of the backup operation mode. Factory setting (table below) will be used if not otherwise specified. Specify the specification for option code /Q (e.g. /C01/S01) OUTPUT SELECTABLE AFTER POWER RECOVERY /A: With [1] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating TERMINAL SCREW MATERIAL /S01: Stainless steel http://www.m-system.co.jp/ JB2 SPECIFICATIONS ES-2642 Rev.4 Page 1/5

RELATED PRODUCTS Programming Unit (model: PU-2x) PC configurator software (model: JXCON) Downloadable at M-System s web site. A dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual for the PC configurator for applicable cable types. GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3.5 screw terminals Screw terminal: Chromated steel (standard) or stainless steel Housing material: Flame-resistant resin (black) Isolation: CAS input or MV output to contact input or power to re-transmitted output to contact output Zero adjustment: -5 to 5 % (front) Span adjustment: 98 to 102 % (front) Indicator LED: RUN output (green), status output (red), command (red), command (red), command (red) Programming: Programming Unit (model: PU-2x); Slidingback response time, - response time, alarm, etc. (Refer to the users manual of JXCON for the adjustments configurable with JXCON.) Alarm output: RUN contact turns off when the high/low alarm for the CAS input trips. INPUT SPECIFICATIONS CAS Input: 4 20 ma DC Input resistance: 25 Ω in manual control mode Contact Input: control command and / command Sensing: 5 V DC @ 3 ma Detection levels ON resistance: 200 Ω, 0.80 V OFF resistance: 100 kω, 4.95 V OUTPUT SPECIFICATIONS Output: 4 20 ma DC Load resistance CAS control mode: Allowable load for CAS signal minus 50 Ω control mode: 0 750 Ω Relay Output: status and RUN output; 120 V AC @ 1 A or 24 V DC @ 1 A Maximum switching voltage: 250 V AC or 30 V DC Maximum switching power: 120 VA or 24 W Minimum load: 5 V DC @100 ma Mechanical life: 2 10 7 cycles INSTALLATION Power consumption CAS mode: Approx. 120 ma at 24 V mode: Approx. 180 ma at 24 V Operating temperature: -5 to 55 C (23 to 131 F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 450 g (0.99 lb) PERFORCE in percentage of span Alarm setting accuracy: ±0.5 % Re-transmitted output accuracy: ±0.4 % CAS to or to CAS switching accuracy: ±0.5 % MV output terminal is open during the time switching the internal relay ( 10 msec.) when turning CAS to or to CAS mode. Temp. coefficient: ±0.015 %/ C (±0.008 %/ F) Re-transmitted output response time: 20 msec. Output memory at power OFF: E 2 PROM (non-volatile memory) Insulation resistance: 100 MΩ with 500 V DC Dielectric strength: 1000 V AC @ 1 minute (CAS input or MV output to contact input or power to retransmitted output to contact output) 1500 V AC @ 1 minute (CAS input or MV output or contact input or power or re-transmitted output or contact output to ground) OPERATING MODES CASCADE CONTROL MODE The JB2 allows the CAS input (cascade control signal) from the PID controller to pass through at the MV output terminals. UAL CONTROL MODE When the external command contact is closed, the JB2 turns on to manual control mode. Actual output signal is determined by following three operation modes: MODE 1: Holds the CAS control signal at the moment of the command. MODE 2: Goes back the preset time period and hold the CAS control signal at that moment. MODE 3: Holds a specific value preset by the Programming Unit (PU-2x). In this mode, the output can be manipulated with external or commands. When the command contact is opened, the CAS control signal is recovered with smooth transition. TRANSITION FROM TO CAS CONTROL MODE The JB2 increases/decreases the MV output until it reaches http://www.m-system.co.jp/ JB2 SPECIFICATIONS ES-2642 Rev.4 Page 2/5

to the same value as the CAS control signal, and turns on to CAS control mode. The response time constant can be set/changed with the PU-2x. If the external command contact is closed during the transition, the JB2 output holds the signal of this moment and turns on to control mode. JB2 ACTIONS AT POWER RECOVERY The actions at power recovery can be switched by actions and settings at the moment of power failure. a) command status is OFF at recovery. CAS mode b) command status is ON at recovery. Output value after power on is FIXED VALUE. Manual control starts with fixed output value. Output value after power on is HOLD VALUE. Manual control starts with output value at the moment of power failure. (Approx. 0.3 second is required to switch from CAS to when the power supply is recovered. Refer to the instruction manual.) DIFFERENCE BETWEEN JB AND JB2/A Means to back up the output value is different. JB: STATIC RAM (A large capacitance capacitor holds the value until the capacitor is discharged.) JB2: E 2 PROM (Output value is stored at E 2 PROM and held until the next rewrite.) Therefore, the output value at power recovery during control mode is as shown below. JB: When recovering within the memory time, JB outputs the value at the moment of power failure. When recovering without the memory time, JB outputs the fixed value. JB2/A: The output value at power recovery is selectable, whether the value at the moment of power failure or the fixed value. COMPATIBILITY BETWEEN JB2 AND JB2/A For JB2/A, the operation at power recovery is selectable. When JB2 (without /A ) is replaced with JB2/A compatibly, set JB2/A according to the instruction manual. http://www.m-system.co.jp/ JB2 SPECIFICATIONS ES-2642 Rev.4 Page 3/5

EXTERNAL VIEW Zero Adj. Span Adj. RUN Output LED. Status LED Command LED Command LED. Command LED Modular Jack Front Cover (open) EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) CLAMP (top & bottom) 7.8 (.31) 20 (.79) DIN RAIL 35mm wide 7 14 6 5 12 4 3 80 (3.15) 24.5 (.18) dia. MTG HOLE 25 (.98) deep 8 80 (3.15) 50 (1.97) 107 (4.21) 14M3.5 SCREW 9 15 10 1 60 (2.36) 11 2 72 (2.83) 136 (5.35) [3.3 (.13)] 72 (2.83) When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM CAS CAS INPUT 4 20mADC 9 15 Cas Input CAS Output MV Input 2 11 4 20mADC Isolation Isolation Z S COMD 8 5 6 Contact Input Tracking Ry Ry Output Driver 1 10 4 12 3 RE-TRANSMITTED OUTPUT 4 20mADC STATUS CONTACT RUN CONTACT PU-2x MODULAR JACK SERIAL TRANSMISSION LINE DC / DC Converter 7 14 POWER Base Socket http://www.m-system.co.jp/ JB2 SPECIFICATIONS ES-2642 Rev.4 Page 4/5

APPLICATION EXAMPLES Output backup for a PID controller in the DCS system RE-TRANSMITTED OUTPUT PID CONTROLLER JB2 COMD Control loop utilizing pulse duration output from a computer RE-TRANSMITTED OUTPUT COMPUTER JB2 Specifications are subject to change without notice. http://www.m-system.co.jp/ JB2 SPECIFICATIONS ES-2642 Rev.4 Page 5/5