1 FRKPV-DS-01-MTLH FRKPV-PJ-01-MTLH FRKPV-PJ-02-MTLH FRKPV-PJ-03-MTLH FRKPV-FS-01-MTLH FRKPV-FS-02-MTLH FRKPV-BS-01-MTLH FRKPV-BS-02-MTLH FRKPV-BS-03-MTLH FRKPV-BS-04-MTLH FRKPV-OC-01-MTLH FRKPV-IC-01-MTLH FRKPV-FO-01-MTLH FRKPV-FO-02-MTLH FRKPV-FO-03-MTLH FRKPV-SJ-01-MTLH FRKPV-PR-01-MTLH FRKPV-LE-01-MTLH FRKPV-RD-01-MTLH FRKPV-TP-01-MTLH FRKPV-TL-01-MTLH FRKPV-TL-02-MTLH C & I DISCLAIMER EXPANDED PANEL JOINT ENGAGED PANEL JOINT INTERMEDIATE SUPPORT MULTI-STORY FIRE STOPPING DETAIL MULTI-STORY FIRE STOPPING ASSEMBLY BASE DETAIL FLUSH BASE AT NOTCHED CONCRETE BASE AT OVERHANG BASE AT OVERHANG OUTSIDE CORNER INSIDE CORNER FRAMED OPENING HEAD FRAMED OPENING JAMB FRAMED OPENING SILL STACK JOINT PARAPET DETAIL LOW EAVE DETAIL RAKE DETAIL PANEL TERMINATION TRIM END LAP TRIM END LAP WITH HEMS INDEX SHEET
2 DISCLAIMERS: THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED ON TYPICAL DESIGN PRACTICES FOR MOST U.S. AND CANADIAN CLIMACTIC ZONES. (THE PRIMARY VAPOR BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER). PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS. ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION AND ILLUSTRATION PURPOSES ONLY. WALL SYSTEM DEFLECTIONS ARE TO BE DETERMINED BY THE ENGINEER OF RECORD. ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION AND ILLUSTRATION PURPOSES ONLY. CONTACT KINGSPAN TECHNICAL SERVICES FOR MAXIMUM ALLOWABLE PANEL SPANS AND FASTENING PATTERNS. DISCLAIMER
3 CORE DEPTHS: 2", 2.5", 3", 4", 5", 6" STEEL GAUGES: EXTERIOR: (REFER TO PROFILE) INTERIOR: 26, 24, 22 MODULE WIDTH: 24", 30", 36", 42" PANEL ORIENTATION: VERTICAL REVEAL: 3 8" KARRIER CONFIGURATION REQUIRES 3 8" REVEAL EMBOSSING: EXTERIOR: STUCCO / SMOOTH* INTERIOR: STUCCO / SMOOTH LENGTHS: MINIMUM: 8'-0" MAXIMUM: 53'-0" SHADOWLINE INTERIOR FACE FEMALE JOINT KS SHADOWLINE (SL) EXTERIOR FACE SHADOWLINE (22GA, 24GA, 26GA) 42" COVERAGE (36", 30", & 24" OPTIONAL) OPTIONAL TRIMLESS ENDS AND FOLDED CORNERS MALE JOINT 2" - 6" 3 8 " REVEAL () SHADOWLINE INTERIOR FACE FEMALE JOINT KS MICRO RIB (MR) EXTERIOR FACE MICRO-RIB (24GA, 22GA ONLY) 42" COVERAGE (36", 30", & 24" OPTIONAL) OPTIONAL TRIMLESS ENDS AND FOLDED CORNERS MALE JOINT 2" - 6" 3 8 " REVEAL () SHADOWLINE INTERIOR FACE FEMALE JOINT KS MINI-MICRO RIB (MMR) EXTERIOR FACE MINI MICRO-RIB (24GA ONLY) (*SMOOTH ONLY) 42" COVERAGE (36", 30", & 24" OPTIONAL) OPTIONAL TRIMLESS ENDS AND FOLDED CORNERS MALE JOINT 2" - 6" 3 8 " REVEAL () SHADOWLINE INTERIOR FACE FEMALE JOINT KS AZTECO (AZ) EXTERIOR FACE AZTECO (24GA, 22GA ONLY) 42" COVERAGE (36", 30", & 24" OPTIONAL) OPTIONAL TRIMLESS ENDS AND FOLDED CORNERS MALE JOINT 2" - 6" 3 8 " REVEAL () EXPANDED PANEL JOINT
4 CORE DEPTHS: 2", 2.5", 3", 4", 5", 6" STEEL GAUGES: EXTERIOR: (REFER TO PROFILE) INTERIOR: 26, 24, 22 MODULE WIDTH: 24", 30", 36", 42" PANEL ORIENTATION: VERTICAL EMBOSSING: EXTERIOR: STUCCO / SMOOTH* INTERIOR: STUCCO / SMOOTH LENGTHS: MINIMUM: 8'-0" MAXIMUM: 53'-0" FEMALE JOINT INTERIOR FACE KS MINI WAVE (MW) SHADOWLINE MALE JOINT 2" - 6" EXTERIOR FACE MINI-WAVE (24GA, 22GA ONLY) 42" COVERAGE (36", 30", & 24" OPTIONAL) 3 8 " REVEAL () SHADOWLINE INTERIOR FACE FEMALE JOINT KS SL FLAT EXTERIOR FACE FLAT (26GA, 24GA, 22GA) 42" COVERAGE (36", 30", & 24" OPTIONAL) MALE JOINT 2" - 6" 3 8 " REVEAL () EXPANDED PANEL JOINT
5 GYPSUM BOARD (2) 1 4" - 14 HEX HEAD THROUGH FASTENERS W/O WASHER AT EACH SUPPORT (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) FASTENERS W/ WASHER. (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) MALE JOINT SET KARRIER RAIL IN BUTYL SEALANT AT FASTENER HORIZONTAL SUPPORT SEALANT, ENSURE THERE ARE NO GAPS OR VOIDS OF SEALANT IN JOINT CONTINUOUS BUTYL SEALANT (OPTIONAL) FEMALE JOINT CONTINUOUS KARRIER FLAT RAIL FACADE PANEL AND FASTENING NOT SHOWN FOR CLARITY. SEE NEXT DETAIL FOR FACADE FASTENING DETAILS WALL PANEL INSTALLATION DIRECTION EXPANDED PANEL JOINT
6 GYPSUM BOARD (2) 1 4" - 14 HEX HEAD THROUGH FASTENERS W/O WASHER AT EACH SUPPORT (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) FASTENERS W/ WASHER. (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) SET KARRIER RAIL IN BUTYL MALE JOINT FEMALE JOINT SEALANT, ENSURE THERE ARE NO GAPS OR VOIDS OF SEALANT IN JOINT CONTINUOUS BUTYL SEALANT (OPTIONAL) 1" NOTING FOR HAT CHANNEL AND RAIL INSTALLATION REMOVED FOR CLARITY.FOR INSTALLATION OF RAIL AND HAT CHANNEL NOTES, SEE PREVIOUS DETAIL CLIP WALL PANEL INSTALLATION DIRECTION ENGAGED PANEL JOINT
7 GYPSUM BOARD FASTENERS W/ WASHER (BEYOND) (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) (2) 1 4" - 14 HEX HEAD THROUGH FASTENERS W/O WASHER AT EACH SUPPORT (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) HORIZONTAL SUPPORT CONTINUOUS KARRIER FLAT RAIL CLIP SET KARRIER RAIL IN BUTYL PANEL THICKNESS 1" CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS INTERMEDIATE SUPPORT
8 GYPSUM BOARD FASTENING AND OTHER MATERIALS NOT SHOWN FOR CLARITY OF DETAIL FLOOR SLAB, FRAMING AND OTHER MATERIALS KARRIER PANEL INSTALLED VERTICALLY FACADE PANEL (INSTALLED VERTICALLY) F.F. 8" MIN COMPLETELY FILL VOID BETWEEN INSULATED METAL PANEL SYSTEM AND FACADE WITH MIN 4PSI CONTINUOUS FIRE BLOCKING AT EACH FLOOR LINE INSULATION WASHER AND 12" O.C. VOID MULTI-STORY FIRE STOPPING DETAIL
9 GYPSUM BOARD KARRIER PANEL AND RAIL INSTALLED VERTICALLY FASTENING AND OTHER MATERIALS NOT SHOWN FOR CLARITY OF DETAIL KARRIER FLAT RAIL FACADE PANEL (INSTALLED VERTICALLY) FLOOR SLAB, FRAMING AND OTHER MATERIALS COMPLETELY FILL VOID BETWEEN INSULATED METAL PANEL SYSTEM AND FACADE WITH MIN. 4 PSI CONTINUOUS FIRE BLOCKING AT EACH FLOOR LINE INSULATION WASHER AND 12" O.C. MULTI-STORY FIRE STOPPING ASSEMBLY
10 GYPSUM BOARD CONTINUOUS KARRIER FLAT RAIL CLIP SET KARRIER FLAT RAIL IN BUTYL FASTENERS W/ WASHER (BEYOND) (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) (2) 1 4" - 14 HEX HEAD THROUGH FASTENERS W/O WASHER AT EACH SUPPORT (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) BASE FLASHING SEALANT BELOW BASE FLASHING SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT FASTENER TO CONCRETE BASE ANGLE W/ MINIMUM 3" VERT. LEG FOR PANEL ATTACHMENT SET IN SEALANT BASE DETAIL FLUSH
11 GYPSUM BOARD SET KARRIER FLAT RAIL IN BUTYL CONTINUOUS KARRIER FLAT RAIL CLIP (2) 1 4" - 14 HEX HEAD THROUGH FASTENERS W/O WASHER AT EACH SUPPORT (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT FASTENERS W/ WASHER (BEYOND) (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) BASE FLASHING SEALANT BELOW BASE FLASHING FASTENER TO CONCRETE BASE ANGLE W/ MINIMUM 3" VERT. LEG FOR PANEL ATTACHMENT SET IN SEALANT SEALANT BASE AT NOTCHED CONCRETE
12 GYPSUM BOARD SET KARRIER FLAT RAIL IN BUTYL CONTINUOUS KARRIER FLAT RAIL CLIP (2) 1 4" - 14 HEX HEAD THROUGH FASTENERS W/O WASHER AT EACH SUPPORT (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT FASTENERS W/ WASHER (BEYOND) (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) BASE FLASHING FASTENER TO CONCRETE BASE ANGLE W/ MINIMUM 3" VERT. LEG FOR PANEL ATTACHMENT SET IN SEALANT SEALANT BASE AT OVERHANG
13 GYPSUM BOARD SET KARRIER FLAT RAIL IN BUTYL CLIP FASTENERS W/ WASHER (BEYOND) (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT (2) 1 4" - 14 HEX HEAD THROUGH FASTENERS W/O WASHER AT EACH SUPPORT (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) BASE FLASHING FASTENER TO CONCRETE BASE ANGLE W/ MINIMUM 3" VERT. LEG FOR PANEL ATTACHMENT SET IN SEALANT SEALANT BELOW BASE FLASHING BASE AT OVERHANG
14 GYPSUM BOARD FASTENER, AS POP RIVETS OUTSIDE CORNER TRIM OUTSIDE CORNER ASSEMBLY F.I.P. INSULATION AS (BY OTHERS) FASTENERS (HAT CHANNEL FASTENING FASTENING) 3 4 " PHIL PAN HEAD FASTENERS (HAT CHANNEL FASTENING FASTENING) CLOSURE AND FASTENER CLIP 1 4 " - 14 HEX HEAD THROUGH FASTENERS W/ 12" O.C. (PANEL FASTENING) SEALANT INSIDE CORNER TRIM 3 4 " PHIL PAN HEAD HORIZONTAL SUPPORT OUTSIDE CORNER
15 GYPSUM BOARD FASTENERS W/ WASHER (BEYOND) (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) 3 4 " PHIL PAN HEAD SEALANT INSIDE CORNER TRIM F.I.P. INSULATION AS (BY OTHERS) CLOSURE AND FASTENER SEALANT FASTENERS W/ 12" O.C. ( PANEL FASTENERS) 3 4 " PHIL PAN HEAD FASTENERS (HAT CHANNEL FASTENERS) HORIZONTAL SUPPORT CORNER ASSEMBLY FASTENER, AS POP RIVETS OUTSIDE CORNER TRIM W/ POP 12" O.C. INSIDE CORNER
16 GYPSUM BOARD CONTINUOUS KARRIER FLAT RAIL CLIP SET KARRIER FLAT RAIL IN BUTYL (2) 1 4" - 14 HEX HEAD THROUGH FASTENERS W/O WASHER AT EACH SUPPORT (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) FRAMED OPENING DRIP FLASHING ASSEMBLY SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT EXPOSED SEALANT DOOR/WINDOW FRAME FRAMED OPENING HEAD
17 GYPSUM BOARD FRAMED OPENING DOOR/WINDOW FRAME 1 4 " - 14 THROUGH FASTENER SEALANT 1 4 " - 14 HEX HEAD THROUGH FASTENERS W/ 12" O.C. (PANEL FASTENER) 1 4 " - 14 HEX HEAD THROUGH FASTENER (HAT CHANNEL FASTENER) EXPOSED SEALANT SEALANT CLOSURE ASSEMBLY JAMB FLASHING ASSEMBLY WITH POP RIVETS FRAMED OPENING JAMB
18 GYPSUM BOARD EXPOSED SEALANT SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT DOOR/WINDOW FRAME MITER CUT JOINTS WHERE SILL TRIM ASSEMBLY CLOSURE ASSEMBLY CLIP CONTINUOUS KARRIER FLAT RAIL 1 4 " - 14 THROUGH FASTENER SEALANT (2) 1 4" - 14 HEX HEAD THROUGH FASTENERS W/O WASHER AT EACH SUPPORT FASTENERS W/ WASHER. (BEYOND) FRAMED OPENING SILL
19 FIELD NOTCH KARRIER RAIL AS AT STACK FLASHING/ STACK JOINT FOR OVERLAP FASTENERS W/ WASHER. (BEYOND) CONTINUOUS KARRIER FLAT RAIL (NOTCHED AS ) (2) 1 4" - 14 HEX HEAD THROUGH FASTENERS W/O WASHER AT EACH SUPPORT FASTENER AS HORIZONTAL SUPPORTS CLIP SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT (2) 1 4" - 14 HEX HEAD THROUGH FASTENERS W/O WASHER AT EACH SUPPORT (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) * FIELD NOTCH KARRIER RAIL AS * GYPSUM BOARD STACK JOINT
20 GYPSUM BOARD PARAPET BLOCKING FIP INSULATION AS PARAPET ASSEMBLY SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT (2) 1 4" - 14 HEX HEAD THROUGH FASTENERS W/O WASHER AT EACH SUPPORT (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) WRAP MEMBRANE OVER PANEL FACE CLOSURE ASSEMBLY FASTENERS W/ WASHER. (BEYOND) CLIP FASTENER TO PARAPET BACKER SET KARRIER FLAT RAIL IN BUTYL CONTINUOUS KARRIER FLAT RAIL MEMBRANE ROOF & PARAPET BACKER PARAPET DETAIL
21 GYPSUM BOARD REFER TO 900/1000 SERIES ROOF PANEL DETAILS FOR ADDITIONAL INFORMATION FIP INSULATION AS FASTENERS W/ WASHER. (BEYOND) CLIP CLOSURE ASSEMBLY CONTINUOUS KARRIER FLAT RAIL SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT (2) 1 4" - 14 HEX HEAD THROUGH FASTENERS W/O WASHER AT EACH SUPPORT (FASTENER TYPE AND LENGTH VARY DUE TO PANEL THICKNESS AND SUB STRUCTURE TYPE) SET KARRIER FLAT RAIL IN BUTYL EAVE STRUT LOW EAVE DETAIL
22 GYPSUM BOARD REFER TO 900/1000 SERIES ROOF PANEL DETAILS FOR ADDITIONAL INFORMATION RAKE ANGLE FIP INSULATION AS CLIP CLOSURE ASSEMBLY CONTINUOUS KARRIER FLAT RAIL SEALANT BOTH SIDES OF TRIM WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT (2) 1 4" - 14 HEX HEAD THROUGH FASTENERS W/O WASHER AT EACH SUPPORT FASTENERS W/ WASHER. (BEYOND) SET KARRIER FLAT RAIL IN BUTYL RAKE ANGLE RAKE DETAIL
23 GYPSUM BOARD 1 4 " - 14 HEX HEAD THROUGH FASTENERS W/ 12" O.C. (PANEL FASTENING) STRUCTURAL SUPPORTS SEALANT 1 4 " - 14 HEX HEAD THROUGH FASTENERS (HAT CHANNEL FASTENING) CAP TRIM BACKER ROD & SEALANT CLOSURE ASSEMBLY JAMB FLASHING ASSEMBLY WITH POP RIVETS PANEL TERMINATION
24 (2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP MIN. 3" TRIM LAP TRIM END LAP
25 FIELD NOTCH HEM(S) AS MIN. 3" TRIM LAP (2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP TRIM END LAP WITH HEMS
MULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET
KPH-DS-01-MTLV KPH-PP-01-MTLV KPH-PP-02-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-FS-01-MTLV KPH-FS-02-MTLV KPH-FS-03-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV
More informationTHESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.
KPV-DS-01-MTLH C & I DISCLAIMER KPV-PJ-01-MTLH EXPANDED PANEL JOINT KPV-PJ-02-MTLH ENGAGED PANEL JOINT KPV-PJ-03-MTLH INTERMEDIATE SUPPORT KPV-FS-01-MTLH MULTI-STORY FIRE STOPPING DETAIL KPV-FS-02-MTLH
More informationL:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET
KPV-DS-01-BRH KPV-PJ-01-BRH KPV-PJ-02-BRH KPV-PJ-03-BRH KPV-BS-01-BRH KPV-BS-02-BRH KPV-BS-03-BRH KPV-OC-01-BRH KPV-IC-01-BRH KPV-FO-01-BRH KPV-FO-02-BRH KPV-FO-03-BRH KPV-SJ-01-BRH KPV-PR-01-BRH KPV-LE-01-BRH
More information900 SERIES WALL PANELS
CI-DS-01-900 CI-PP-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-PJ-03-900 CI-BS-01-900 CI-BS-02-900 CI-BS-03-900 CI-BS-04-900 CI-BS-05-900 CI-OC-01-900 CI-OC-02-900 CI-IC-01-900 CI-FO-01-900 CI-FO-02-900 CI-FO-03-900
More information400 SERIES VERTICAL INSTALLATION
CI-DS-01-400V CI-PJ-01-400V CI-PJ-02-400V CI-PJ-03-400V CI-BS-01-400V CI-BS-02-400V CI-BS-03-400V CI-BS-04-400V CI-BS-05-400V CI-OC-01-400V CI-OC-02-400V CI-IC-01-400V CI-IC-02-400V CI-FO-01-400V CI-FO-02-400V
More informationKS42 MF SERIES - HORIZONTAL INSTALLATION
CI-DS-01-KSMF H CI-PJ-01-KSMF H CI-PJ-02-KSMF H CI-PJ-03-KSMF H CI-PJ-04-KSMF H CI-PJ-05-KSMF H CI-PJ-06-KSMF H CI-PJ-07-KSMF H CI-PJ-08-KSMF H CI-PJ-09-KSMF H CI-PJ-10-KSMF H CI-PJ-11-KSMF H CI-PJ-12-KSMF
More informationDW VERTICAL INSTALLATION
AR-PJ-01-DW5V AR-PJ-02-DW5V AR-PJ-03-DW5V AR-PJ-04-DW5V AR-BS-01-DW5V AR-BS-02-DW5V AR-OC-01-DW5V AR-OC-02-DW5V AR-OC-03-DW5V AR-IC-01-DW5V AR-IC-02-DW5V AR-IC-03-DW5V AR-FO-01-DW5V AR-FO-02-DW5V AR-FO-03-DW5V
More informationDW HORIZONTAL INSTALLATION
AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S
More informationKS SERIES - VERTICAL INSTALLATION
CS-DS-01-KSV CS DISCLAIMER CS-PJ-01-KSV KS42SL EXPANDED PANEL JOINT CS-PJ-02-KSV KS42SL ENGAGED PANEL JOINT CS-PJ-03-KSV KS45SL EXPANDED PANEL JOINT CS-PJ-04-KSV KS45 FLAT ENGAGED PANEL JOINT CS-PJ-05-KSV
More information900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR
900 SERIES PANEL CI-DS-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-EL-01-900 CI-EL-02-900 CI-EL-03-900 CI-EL-04-900 CI-EL-05-900 CI-EL-06-900 CI-EL-07-900 CI-EL-08-900 CI-RD-01-900 CI-RD-02-900 CI-RD-03-900 CI-EV-01-900
More informationInsulated Panels North America. Installation Guide KarrierPanel Wall System
Insulated Panels North America Installation Guide KarrierPanel Wall System Installation Guide KarrierPanel Wall System Disclaimer This installation guide is only to be used in conjunction with panel installation
More informationTABLE OF CONTENTS A. PBR
TABLE OF CONTENTS A. PBR Panel 1. PBR Panel Architect/Engineer Information....................................... 2 2. PBR Panel UL 90 Requirements............................................... 3 3. PBR
More information~ ~ -
~----------------~ - METL DISCLAIMER: These details are based on industry accepted practices and provide a guideline for proper insulated metal panel and component installation. The location of vapor barriers
More informationSEAL PLATE SP4413 VERTICAL SP4414 1"[25] VERT. PANEL JTS. 1/2"[13] INTERM. SPLICES DESIGN LOADS AND SLAB EDGE DISTANCES. 1 2 NOM.
3 COL 5 16GA. ANGLE SP4413 VERTICAL SEE SUPPORT DRAINGS 1 7/16 SEAL PLATE @ VERT. JNT 1/2 [13] Ă DETAILER NOTE OPTIONAL INSULATION HEN REQUIRED. OF SEAL PLATE PANEL MODULE 2.500 FROM SHELF OF TR. TO TOP
More informationRECOMMENDED INSTALLATION PROCEDURE LEVEL 3
Step 1. Install Sill Flashing Product: 9" or 12" RainBuster #440 SubZero Flashing Tape 1.A Flashing Length = (Rough Opening Width) + 12" 1.B Install sill flashing flush with the sill of the rough opening.
More informationConstruction details: Master-C type profiles and joints:
Construction details: Master-C type profiles and joints: Master-C 3g 32 mm. (1 1/4 ) 1000 mm. (39 3/8 ) outer face inner face 10.5 fixing details: sealing washers shall be installed through a 2-3/8 x 1-9/16
More informationREGAL. Installation Manual
REGAL Installation Manual General Information The details shown on the following pages are suggestions or guidelines for installing the Regal system. The installation details shown here are proven methods
More informationMAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24" O.C. ALL FASTENERS TO PENETRATE WOOD 3/4" MIN. AND METAL FRAMING 1/2" MIN.
PLYWOOD SHEATHING DMI SOFFIT PANEL #10-13 GP PANCAKE HEAD (JC) - J CLOSURE (LC) - L CLOSURE #9-15 X 1 1/2" WOODZAC GP APPROVED MOISTURE BARRIER SOFFIT TO WALL PANEL WPRP-H-01-00 APPROVED MOISTURE BARRIER
More informationTABLE OF CONTENTS A-1
TABLE OF CONTENTS PAGE NUMBER: DETAIL DESCRIPTION A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1...GENERAL INFORMATION C-1...EAVE DRIP DETAIL C-2...EAVE DRIP with GUTTER DETAIL C-3 & C-4...FIXED RIDGE
More informationTremLock T-138 INSTALLATION MANUAL T-138 www.tremcoroofing.com 3735 Green Road Beachwood, Ohio 44122 1.800.852.6013 50 Beth Nealson Drive Toronto, Ontario M4H 1M6 1.800.668.9879 7241 6/8/18 TABLE OF CONTENTS
More informationeco-shake INSTALLATION INSTRUCTION
1 eco-shake INSTALLATION INSTRUCTION NOTE: Shuffling the eco-shakes during installation may be necessary to obtain a uniform color throughout the roof. Due to the natural wood content in the ecoshakes,
More informationC.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit
Horizontal battens between verticals at soffit 2 C.04 600 600 600 600 Cavity batten at 600 mm centres 1 C.03 Batten fixing points 1 C.04 1 C.07 1 C.12 1 C.13 1 C.14 Meter Box Window 1 C.08 1 C.09 800 800
More informationSTEVE ENNIS ARCHITECT 1108 EAST JACKSON STREET MEDFORD, OREGON 97504
ATTACH TO STRUC- TURE ABOVE 1/8"Ø BOLT W/ LOCKING NUT #12 WIRE TIE IN PLANE EACH TEE ANGLED 45 FROM HORIZ ATTACH 2" FROM INTERSECTION COMPRESSION POST LOCATE WITHIN 2" OF TEE INTERSECTION SIZE STRUTS FOR
More informationGLOSSARY OF TERMS SECTION 8
GLOSSARY OF TERMS SECTION 8 Anchor Bolt Angle Base Plate Bay Blocking CCB Centerline Chord Cladding Clip Closure Strip An A-307 steel bolt embedded in the concrete footing to anchor the base plate of the
More informationRECOMMENDED INSTALLATION PROCEDURE LEVEL 3
45 45 6 6 Step 1. Modify Weather Resistive Barrier 1.A Cut the weather resistive barrier flush to the recessed opening (per diagram). Remove the cut away weather resistive barrier, exposing recessed opening
More informationFlexLoc. Technical/Installation Information
Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE FLEXLOC PANELS. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES BEFORE
More informationBest Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.
Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications. EXTERIOR INSULATION & FINISH SYSTEM CONSTRUCTION Data Published Courtesy
More informationInstallation Instruction 3-D Model 3D 03/01/17. 0 Flush Siding Horizontal System N/C WPS, Inc.
I B D L K C E G M F A H J Installation Instruction 3-D Model 3D 03/01/17 Detail: System Type: Scale: Drawn By: 0 Flush Siding Horizontal System N/C WPS, Inc. Wall Panel System, Inc. 15/16" 1 1/4" Bottom
More informationWESTERN WAVE Panel. Horizontal Installation and Technical Information
WESTERN WAVE Panel Horizontal Installation and Technical Information Western States Western Wave Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page
More informationWESTERN WAVE Panel. Vertical Installation and Technical Information
WESTERN WAVE Panel Vertical Installation and Technical Information Western States Western Wave Wall and Soffit Panels (Vertical) Installation, Flashings & Shop Drawing Detail Guide Section Notes to Designer
More informationForceField Air & Water Barrier System. installation instructions
ForceField Air & Water Barrier System installation instructions Protection and Performance inside and out The ForceField air and water barrier system consists of engineered wood sheathing panels laminated
More informationINSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN
MINNEAPOLIS, MN 2-0- 2-- General Notes Abbreviations Deviations from Architectural Specifications Deviations from Architectural Drawings ALUM. = ALUMINUM B.O. = BY OTHERS CONT. = CONTINUOUS. = CLEARANCE
More informationPROVEN DEPENDABLE SUSTAINABLE
B/SOFFIT FP CLIP 24" O.C. MAX SECTION "A-A" PLYWOOD SHEATHING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. A B/SOFFIT A (JC) - J CLOSURE DMI WALL PANEL PLYWOOD SHEATHING SOFFIT TO WALL PANEL FR10-V-01-00 B/SOFFIT
More informationWALL TO FABRICATED FLOOR
WALL TO FABRICATED FLOOR PERIMETER WALL IS HELD IN PLACE BY WOODEN STRIP SCREED OPTIONAL NSF COVED FLOOR IS SHOWN PARTITION WALL IS HELD IN PLACE BY WOODEN STRIP SCREED OPTIONAL NSF COVED FLOOR IS SHOWN
More informationINSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS
2008 Pella Corporation Part Number: 803V0101 INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS Installation Instructions for Typical Wood Frame Construction. These instructions were developed
More informationDMI FR1511 PANEL (JC) - J CLOSURE DMI WALL PANEL SOFFIT TO WALL PANEL PROVEN DEPENDABLE SUSTAINABLE METAL ENVELOPE SYSTEMS SINCE 1988
FP CLIP 24" O.C. MAX B/SOFFIT 5 1/2" SECTION "A-A" PLYWOOD SHEATHING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. A B/SOFFIT A (JC) - J CLOSURE DMI WALL PANEL PLYWOOD SHEATHING SOFFIT TO WALL PANEL FR15-V-01-00
More informationTuff-Rib Install Guide
Install Guide bestbuymetalroof.com Page 2 of 27 Page 3 of 27 1. Page 4 2. a. Installation Guide b. Panel Squaring Pages 5, 6 Pages 7, 8 3. Pages 9, 10 4. a. Fascia (optional) b. Eave / 1.5x3.5 Angle c.
More informationEkoroof LiteTile Dimensions
Ekoroof LiteTile Dimensions 7 3 3.5 Height 40 Width 20 Length Weight per Panel: 3 kg / 6.61 lbs 2 2 Area per panel 800 in / 5.55 ft 2 Panels per Square: 20 (including overlap, for a 100 ft covered area)
More information40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)
http://www.sundancesupply.com 40mm Thermoclick Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) U-Profile 12' Lengths $39 Out System offers a complete set of extrusions and accessories
More informationSpeedDeck. Fixing and Handling Guide
SpeedDeck Section 1 Delivery/Storing On Site/Handling l SpeedDeck is factory or on-site manufactured. l Straight SpeedDeck bundles are a maximum 1 tonne, sheets nestled and banded with polypropylene or
More informationA REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS
WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME
More informationTABLE OF CONTENTS A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION
TABLE OF CONTENTS PAGE NUMBER: DETAIL DESCRIPTION A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION MATRIX DETAILS C-1...FASCIA/SOFFIT DETAIL with ANGLE C-2...BUILDING/SOFFIT
More informationInspire Aledora Slate Application Guidelines
July 2014 Inspire Aledora Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry bar,
More informationFinesse Profiles. Nailstrip
Installation Details Profile and Lap Detail 265/465 38mm NAILSTRIP *other widths available CD GRADE PLYWOOD 19mm STRUCTURE SILICONE * MIN 20mm VENTILATION GAP * WHEN ROOF PITCH IS UNDER 7.5 OR TOTAL COMBINED
More informationEffective February, 2015
Effective February, 2015 Table of Contents Ensuring System Performance 1 Components 2 Frequently Asked Questions 3 List of Tools 3 Before you Begin Preparation 3 Quality Tips 4 Cold Weather Tips 4 Cleaning
More informationTools required by installer: Materials required by installer:
Installation Guidelines For Quaker Window Products Vinyl product line (Single Hung, Double Hung, Sliding Window, Fixed Window, Casement, Awning, and Hopper) Installer: Read these instructions completely
More information3M Air and Vapour Barrier 3015 Technical guide
3M Air and Vapour Barrier 3015 Technical guide Product overview Typical physical properties For installation ease and flexibility, 3M Air and Vapour Barrier 3015 High performance 3M acrylic adhesive grabs
More informationTable of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection...
Table of Contents Section Page Notes to Designer/User... 2-3 Map of Typical Roof Conditions... 4 Fastener Placement... 5 Fastener Selection... 6 Ridge/Hip Flashing... 7 Valley Flashing... 8 Eave Flashings...
More informationCARRIER OVERHANG 1'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise)
DETAIL 5 32 5 " 27 32 " 6" OPTIONAL FLAT RECESSED CLOSURE 1 1 4 " 17 32 " 1 25 32 " OPTIONAL BUTTERFLY CLOSURE CARRIER OVERHANG 1'-0" MAX CARRIER SPAN 4'-0" 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER
More informationDear Contractor, I am glad that you are interested in our window rebate program.
Dear Contractor, I am glad that you are interested in our window rebate program. I have included three documents with this letter. One is our form to indicate your intention to participate in the program.
More informationBARRELL VAULT BATTENLESS
i BARRELL VAULT BATTENLESS INSTALLATION GUIDE INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Barrel Vault battenless
More informationSG-30 A P P L I C A T I O N I N S T R U C T I O N S. Directions For Application
1 2 3 General Instructions NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE
More informationSystem for 2+ Level Buildings
Issued Sept 205 Contact Info@symonite.co.nz System for 2+ Level Buildings Typical Details Issued: September 205 TYPICAL DETAILS CONTENTS.0 TYPICAL VERTICAL JOINTS 2.0 EXT. CORNER / TYPICAL HORIZONTAL JOINT
More information14000 I/O Series Flush Glaze. Fabrication and Installation Instructions
14000 I/O Series Flush Glaze Fabrication and Installation Instructions Last saved on 12/18/2009 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...4 ACCESSORIES...5 OVERVIEW...6
More informationSteel Roofing & Siding INSTALLATION GUIDE
Steel Roofing & Siding INSTALLATION GUIDE Your Authorized Dealer is: WASHINGTON Auburn (800) 700-7228 WASHINGTON Spokane (866) 321-5954 www.nuraymetals.com CALIFORNIA Redlands (800) 806-8729 CONTENTS BEFORE
More informationCambridge English Application Instructions
Cambridge English Application Instructions ROOF SLOPE: Never apply asphalt shingles to roof slopes less than 2:12. For slopes 2:12 to 4:12 (LOW SLOPE), see special underlayment requirements outlined below.
More informationTable of Contents Light Gauge Metal Roof & Wall Panels
Table of Contents Light Gauge Metal Roof & Wall Panels Installation Guide for Delta Rib, Nor-Clad, Strata Rib & 2-1/2 Corrugated Introduction Important Notice Notes: April 2008 Minimum Recommended Tools
More informationINSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.
for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) Thank you for selecting JELD -WEN products. Attached are JELD-WEN s recommended installation instructions for metal clad wood windows
More information26- H i n g e d P a t i o D o o r s - I n s w i n g
Contents Hinged Patio Doors - Inswing Basic Unit Details... 2 Options / Accessories Accessibility Option... 5 Andersen Grilles... 6 Extension s... 7 Anchoring Methods... 8 Joining Details... 9 Suggested
More informationThe Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA
TRS 9 35MM 78MM 150MM 78MM THICKNESS END SPAN INTERNAL SPAN MINIMUM PITCH 0.55MM 2.30M 3.20M 3 DESCRIPTION TRS 9 profile is designed for commercial and industrial roofing. The profile is suitable for low
More information2 ½ Corrugated Panel Installation Specifications
2 ½ Corrugated Panel Installation Specifications ROOF APPLICATION: Roof slope must be a minimum of a 2/12 pitch to use this product. When using this product butyl lap sealant is recommended for all slopes.
More informationA P P L I C A T I O N I N S T R U C T I O N S
1 2 3 General Instructions NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE
More informationFold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE
Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE This instruction guide provides the minimum recommended procedures to correctly prepare the rough opening, install a fold-a-way patio door unit and apply
More informationAll Window Installation Instruction
1 All Window Installation Instruction Hurd Window Installation Instructions for Nail Fin & Wood Brick Mould Units Nail Fin Windows See Pages 2-11 Wood Brick Mould Windows See Pages 2-6, 8 & 12BM - 14BM
More informationThermoSpan EPS. Metalcraft COMMERCIAL ROOFING CREPS. Insulated Panel Systems DETAIL LIST
ThermoSpan EPS DETAIL LIST 00 / 15 COVER SHEET 01 / 15 RIDGE DETAIL 02 / 15 HEAD FLASHING DETAIL 03 / 15 EAVES GUTTER DETAIL 04 / 15 INSULATED GUTTER 05 / 15 INSULATED BOX GUTTER 06 / 15 BARGE CAPPING
More informationInstallation Instructions for Standard Lap and Self-Aligning Lap Siding
Installation Instructions for Standard Lap and Self-Aligning Lap Siding 7/16 in. Standard Laps Include: All Old Mill Widths, Cedar Shake Lap and Smooth Lap 1/2 in. Self-Aligning Include: 8 in. and 12 in.
More informationULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS
ULTRA WINDOW & DOOR S AND RECEIVERS INSTALLATION INSTRUCTIONS! CAUTION: *REMEMBER SAFETY FIRST* Proper Eye and! Hearing Protection must always be worn during installation of all window and door products.
More informationHOLLOW METAL DOOR/WINDOW SYSTEM FOR THERMALSAFE CF WALLS WINDOW ASEMBLY GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY
HOLLOW METAL DOOR/WINDOW SYSTEM FOR THERMALSAFE CF WALLS WINDOW ASEMBLY GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY TABLE OF CONTENTS DETAIL TITLE PAGE
More informationNorwood Windows Permaglass Fiberglass Products Installation Instruction
Norwood Windows Permaglass Fiberglass Products Installation Instruction Care and storage of fiberglass windows: Fiberglass products purchased from Norwood Windows must be stored in a dry sheltered area
More informationSLATE & SHINGLE INSTALLATION
EAVE EDGE Apply a small strip of roofing paper to the bottom of eave. Eave flashing is attached to substrate with roofing nails every 9". Install underlayment over entire roof. (See Fig. 1) PAGE 1 Bend
More informationInspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square
December 2017 Classic Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry bar,
More informationWEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS
CORE WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS Proper Window & Door Flashing Although all possible measures have been taken to insure the accuracy of the material presented,
More informationUC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER
CAMPUS STANDARDS APPENDIX I UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 WINDOW INSTALLATION SEQUENCING GUIDE Issued By: Pyatok Architects and Allana Buick &
More informationGIRTS ON BACK OF BUILDING
GIRTS ON BACK OF BUILDING ALL GIRTS ARE 1 1/2 SQUARE TUBE. GIRT LENGTHS FOR 12, 20, 24, AND 30 WIDE BUILDINGS: ON 12 WIDE BUILDINGS GIRTS ARE 67 3/4 LONG ON 20 WIDE BUILDINGS GIRTS ARE 56 3/4 LONG ON 24
More informationTuff Rib Panel Installation Specifications
Tuff Rib Panel Installation Specifications ROOF APPLICATION: Roof slope must be a minimum of a 2/12 pitch to use this product. For slopes lower than a 3/12 pitch, lap sealant is suggested on the side laps
More informationCOMPOSITE SIDING INSTALLATION GUIDE
CENTURY HOME LIVING COMPOSITE SIDING INSTALLATION GUIDE Read all instructions prior to installing any siding product. Failure to install and finish this product in accordance with all local building codes,
More informationProSnap 100 STANDARD DETAILS
ProSnap 100 OVER WOOD DECK STANDARD DETAILS Austin - Headquarters/Sales Office 830 Sagebrush Drive Austin, TX 78758 (512) 452-1515 (800) 428-7412 Fax (512) 833-7499 www.ctmrs.com email: info@ctmrs.com
More informationROOF CURB INSTALLATION INSTRUCTIONS: VERTICAL STANDING SEAM PANEL
: p: (800) 284-1412 f: (903) 759-3598 www.lmcurbs.com 827 fisher rd longview, tx 75604 Installation Check List: Attach Sub-Frames Layout Curb on Back-up Channels Apply Sealants & Set Curb in Place Fasten
More informationAluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement
Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement 1 Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement The following instructions are a supplement
More informationSTACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS
STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS 1290363 Revision 1 12/16 Page 1 Weather Shield Mfg., Inc. NOTICE CAUTION! Failure to install and maintain our product according to these instructions
More informationInstallation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.
Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installer: Read these instructions completely before starting any installation.
More informationDoublelok I UltraDek Perimeter Trim Reference Northern Large Trim
( - Doublelok I UltraDek Perimeter Trim Reference Northern Large Trim DLOOOOS Doec '14r"l;s 0 JD "'\ GUTTER GUTTER LAP GUTTER CAP EXPANSION COVER GUTTER SUPPORT F2108 2" LAP F2109 F2110/F629 F319 or
More informationEagle clad double-hung window installation instructions
Eagle clad double-hung window installation instructions These instructions are for typical installation in new typical wood frame wall construction. These instructions and methods are not intended for
More informationCurtain Wall Installation Guide
Curtain Wall Installation Guide Curtain Wall Installation Guide 1 IMPORTANT NOTICES! Important Notices & Information Manufacturer s Notes: The building envelope must be correctly prepared with weather
More informationDura-Lock Roof System
DLR-14 Dura-Lock Roof System Assembly and Installation Instructions Read the instructions before starting the job. They explain the steps required to produce a finished product that will meet factory specifications.
More informationALPINE TRAY. To get the best from this product please follow these recommendations.
F I X I N G D E TA I L S ALPINE TRAY The standing seam roofing profile is designed to withstand some of New Zealand s harshest weather in our toughest environments. To get the best from this product please
More informationPebbletex Adhered Mat Design. Typical Details
Pebbletex Adhered Mat Design Typical Details (THIS PAGE INTENTIONALLY LEFT BLANK) Pebbletex Adhered Mat Design TABLE OF CONTENTS 1. Pebbletex Adhered Mat Design Application (Plan VIew) 2. Pebbletex Adhered
More informationGlasRoc Sheathing Type X
Wall / Fire-Rated Systems 3-5/8" (92 mm) Steel Studs ProRoc Steel Stud System 3-5/8" (92 mm) Steel Track 3-1/2" (89 mm) Glass Fiber or Mineral Wool Insulation GlasRoc Sheathing Type X UL Design U465 Cavity
More informationRECOMMENDED INSTALLATION PROCEDURE LEVEL 3
Products: 12" RainBuster #415 Self-Adhered Flashing Membrane-40mil 12" RainBuster #415 Self-Adhered Flashing Membrane-25mil 12" RainBuster #420 Nail On Flashing Membrane-25mil RainBuster #430-4.0 Recess
More informationBuildingEnvelope Oldcastle ( ) -
BuildingEnvelope 1-866-Oldcastle (653-2278) - www.obe.com RELIANCE -LT CURTAIN WALL 2" X 7-1/2" / POLYAMIDE PRESSURE PLATE / 1" GLAZING Elev-Reliance-LT-750-PolyPP H0042-Steel-Anchor H5021-ShrBlk-Anchors
More informationWindows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016
Windows Installed into Walls with Polyiso and Wood Framing Installation Instructions Standard Method Revised 10/24/2016 Background There are many acceptable ways to mount and detail windows for support
More informationFlashing Materials. Rough Opening Preparation
Installation Instructions for CertainTeed New Construction Windows Handling vinyl windows CAUTION: Always store vinyl windows and doors in an upright position on a slight angle. Never lay them flat or
More informationCFDTT-01. Control Joint Study (General)
Trim Method Classic Method Notes: Control joints are required and should be located by the designer at the following locations on the construction documents: 144 sf (13.4 sm) is the maximum overall area
More informationWINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS
WINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS These instructions were tested developed for replacing windows in wood-frame wall construction systems
More informationINSTALLATION GUIDELINES: X25 SERIES using perimeter installation fin
INSTALLATION GUIDELINES: X25 SERIES using perimeter installation fin Wall systems designed to manage water or that have been upgraded to manage water are important for a trouble free installation. Site
More informationInstallation Instructions for Old Mill Shingle and Designer Shake Lap Siding
Installation Instructions for Old Mill Shingle and Designer Shake Lap Siding Includes: Cove, Craftsmen Staggered, Diamond, Fish Scale, Octagon, Round and Old Mill Shingle Lap Important: Read and understand
More informationPBR Panel Installation Specifications
4906 St. Stephens Rd. 5780 Hwy 90 W Eight Mile, Al 36613 Theodore, AL 36590 251 456 2254 251 653 1550 251 457 2254(F) 251 653 1514(F) PBR Panel Installation Specifications ROOF APPLICATION: Roof slope
More informationPOCKETING MULTI-SLIDE DOOR SYSTEM
PMSD POCKETING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS READ THESE INSTRUCTIONS COMPLETELY BEFORE STARTING ANY INSTALLATION! CAUTION Lead-based paint may be present in older homes, and the removal
More informationFibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.
Plank joint 600mm stud crs 600mm 600mm 600mm Horizontal Structural Timber Cavity atten 50x20mm H3.1 atten fixing points 800mm 800mm 300mm 800mm Max. Nog spacing 50mm All intermediate battens to be 50x20mm
More informationButyl Flash. Installation Instructions. Prep & General Conditions
Prep & General Conditions All surfaces must be clean, dust free, smooth and dry. Do not apply over sealants or uncured caulks containing plasticizers or solvents. This includes most silicones and polyurethane
More information