900 SERIES WALL PANELS
|
|
- Ellen Robbins
- 6 years ago
- Views:
Transcription
1 CI-DS CI-PP CI-PJ CI-PJ CI-PJ CI-BS CI-BS CI-BS CI-BS CI-BS CI-OC CI-OC CI-IC CI-FO CI-FO CI-FO CI-FO CI-FO CI-FO CI-SJ CI-SJ CI-PR CI-PR CI-LE CI-RK CI-HE CI-TL CI-TL CI-TL CI-TL C & I DISCLAIMER 900 SERIES PANEL PROFILE 900 EXPANDED PANEL JOINT 900 ENGAGED PANEL JOINT INTERMEDIATE SUPPORT BASE DETAIL - FLUSH BASE DETAIL - NOTCHED CONCRETE BASE DETAIL - OVERHANG W/ SUPPORT BASE DETAIL - OVERHANG W/ ANGLE BASE DETAIL - OVERHANG W/ DRIP OUTSIDE CORNER WITH FLAT TRIM OUTSIDE CORNER WITH MITER CUT INSIDE CORNER WITH FLAT TRIM F.O. HEAD WITH DRIP EDGE F.O. TWO PIECE JAMB F.O. ONE PIECE JAMB F.O. ONE PIECE SILL O.H. DOOR HEAD WITH DRIP EDGE O.H. DOOR TWO PIECE JAMB STACK JOINT WITH FLUSH TRIM STACK JOINT WITH PROFILED TRIM PARAPET WITH FLUSH TRIM PARAPET WITH PROFILED TRIM LOW EAVE W/ GUTTER RAKE HIGH EAVE TRIM END LAP TRIM END LAP WITH HEM TRIM END LAP WITH LAP STRIP TRIM LAP AT F.O. INDEX SHEET
2 DISCLAIMER: THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED ON TYPICAL DESIGN PRACTICES FOR MOST U.S. CLIMACTIC ZONES. (THE PRIMARY VAPOR BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER). PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS. COMMERCIAL/INDUSTRIAL DISCLAIMER
3 CORE DEPTHS: 1.5", 2", 2.5", 3", 4", 5", 6" STEEL GAUGES: EXTERIOR: 22, 24 INTERIOR: 26, 24, 22 MODULE WIDTH: " (39 3 8") PANEL ORIENTATION: VERTICAL APPLICATION ONLY EMBOSSING: EXTERIOR: STUCCO / SMOOTH INTERIOR: STUCCO / SMOOTH LENGTHS: MINIMUM: 8'-0" MAXIMUM: 53'-0" " (1000mm) HIGH RIB PROFILE EXTERIOR INTERIOR 1 1 2" 1 1 2" - 6" V-GROOVE PROFILE 900 SERIES PANEL PROFILE
4 1 4 " - 14 STITCH TEK (HEX HEAD OR LOW 24" O.C. ALONG OVERLAP (MAX. 4" FROM PANEL ENDS) 1 4 " - 14 THROUGH FASTENERS W/ WASHER (AS REQUIRED FOR WIND LOAD) 1 4 " - 14 STITCH TEK SCREW (HEX HEAD OR LOW 24" O.C. ALONG OVERLAP (MAX. 4" FROM PANEL ENDS) FIELD APPLIED BUTYL TAPE ENTIRE LENGTH OF OVERLAP 1 4 " - 14 THROUGH FASTENERS W/ WASHER (AS REQUIRED FOR WIND LOAD) FIELD APPLIED CONTINUOUS BUTYL SEALANT WALL PANEL INSTALLATION DIRECTION 900 EXPANDED PANEL JOINT
5 1 4 " - 14 STITCH TEK (HEX HEAD OR LOW 24" O.C. ALONG OVERLAP (MAX. 4" FROM PANEL ENDS) 1 4 " - 14 THROUGH FASTENERS W/ WASHER (AS REQUIRED FOR WIND LOAD) 1 4 " - 14 THROUGH FASTENERS W/ WASHER (AS REQUIRED FOR WIND LOAD) 1 4 " - 14 STITCH TEK SCREW (HEX HEAD OR LOW 24" O.C. ALONG OVERLAP (MAX. 4" FROM PANEL ENDS) FIELD APPLIED BUTYL TAPE ENTIRE LENGTH OF OVERLAP FIELD APPLIED CONTINUOUS BUTYL SEALANT WALL PANEL INSTALLATION DIRECTION 900 ENGAGED PANEL JOINT
6 SEALANT AT PANEL JOINT 1 4 " - 14 THROUGH FASTENERS W/ WASHER (AS REQUIRED FOR WIND LOAD) HORZONTAL SUPPORT INTERMEDIATE SUPPORT
7 1 4 " - 14 STITCH TEK (HEX HEAD OR LOW 24" O.C. ALONG OVERLAP (MAX. 4" FROM PANEL ENDS) SEALANT AT PANEL JOINT 1 4 " - 14 THROUGH FASTENER W/ WASHER (AS REQUIRED FOR WIND LOAD) SEALANT BASE TRIM BASE FLASHING BASE ANGLE W/ MIN. 3" VERT. LEG FOR PANEL ATTACHMENT SEALANT BELOW BASE FLASHING FASTENER TO CONCRETE SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT NOTE: SEE DETAIL CI-TL AND CI-TL FOR TYPICAL TRIM LAP INSTRUCTIONS BASE DETAIL - FLUSH
8 1 4 " - 14 STITCH TEK (HEX HEAD OR LOW 24" O.C. ALONG OVERLAP (MAX. 4" FROM PANEL ENDS) BASE TRIM SEALANT AT PANEL JOINT 1 4 " - 14 THROUGH FASTENERS W/ WASHER (AS REQUIRED FOR WIND LOAD) SEALANT W/ MARRIAGE BEAD TO VERTICAL PANEL JOINT BASE ANGLE W/ MIN. 3" VERT. LEG FOR PANEL ATTACHMENT BASE FLASHING " (TYP.) FASTENER TO CONCRETE SEALANT BELOW BASE FLASHING NOTE: SEE DETAIL CI-TL AND CI-TL FOR TYPICAL TRIM LAP INSTRUCTIONS BASE DETAIL - NOTCHED CONCRETE
9 1 4 " - 14 STITCH TEK (HEX HEAD OR LOW 24" O.C. ALONG OVERLAP (MAX. 4" FROM PANEL ENDS) BASE TRIM SEALANT AT PANEL JOINT 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER (AS REQUIRED FOR WIND LOAD) SEALANT W/ MARRIAGE BEAD TO VERTICAL PANEL JOINT BASE ANGLE W/ MIN. 3" VERT. LEG FOR PANEL ATTACHMENT " (TYP.) SEALANT FASTENER TO CONCRETE NOTE: SEE DETAIL CI-TL AND CI-TL FOR TYPICAL TRIM LAP INSTRUCTIONS BASE DETAIL - OVERHANG W/ SUPPORT
10 1 4 " - 14 STITCH TEK (HEX HEAD OR LOW 24" O.C. ALONG OVERLAP (MAX. 4" FROM PANEL ENDS) BASE TRIM SEALANT AT PANEL JOINT 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER (AS REQUIRED FOR WIND LOAD) SEALANT W/ MARRIAGE BEAD TO VERTICAL PANEL JOINT BASE ANGLE W/ MIN. 3" VERT. LEG FOR PANEL ATTACHMENT " (TYP.) SEALANT FASTENER TO CONCRETE NOTE: SEE DETAIL CI-TL AND CI-TL FOR TYPICAL TRIM LAP INSTRUCTIONS BASE DETAIL - OVERHANG W/ ANGLE
11 1 4 " - 14 STITCH TEK (HEX HEAD OR LOW 24" O.C. ALONG OVERLAP (MAX. 4" FROM PANEL ENDS) BASE TRIM SEALANT AT PANEL JOINT 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER (AS REQUIRED FOR WIND LOAD) SEALANT W/ MARRIAGE BEAD TO VERTICAL PANEL JOINT BASE ANGLE W/ MIN. 3" VERT. LEG FOR PANEL ATTACHMENT " (TYP.) SEALANT BASE TRIM FASTENER TO CONCRETE SEALANT NOTE: SEE DETAIL CI-TL AND CI-TL FOR TYPICAL TRIM LAP INSTRUCTIONS BASE DETAIL - OVERHANG W/ DRIP
12 WILL VARY WITH FIELD CONDITION WILL VARY WITH FIELD CONDITION FIELD CUT OUTSIDE CORNER TRIM F.I.P. INSULATION AS REQUIRED (BY OTHERS) 3 4 " PHIL. PAN HEAD CONTINUOUS BUTYL SEALANT 1 4 " - 14 THROUGH FASTENERS W/ 1 1 8" WASHER (AS REQUIRED FOR WIND LOAD) ATTACHMENT CLIP (BY OTHERS) CONTINUOUS BUTYL SEALANT HORIZONTAL SUPPORT OUTSIDE CORNER WITH PROFILED TRIM
13 WILL VARY WITH FIELD CONDITION WILL VARY WITH FIELD CONDITION FIELD CUT OUTSIDE CORNER TRIM F.I.P. INSULATION AS REQUIRED (BY OTHERS) 1 4 " - 14 "LOW PROFILE" THROUGH FASTENERS W/ 1 1 8" WASHER (AS REQUIRED FOR WIND LOAD) 3 4 " PHIL. PAN HEAD CONTINUOUS BUTYL SEALANT ATTACHMENT CLIP (BY OTHERS) CONTINUOUS BUTYL SEALANT HORIZONTAL SUPPORT OUTSIDE CORNER WITH FLAT TRIM
14 WILL VARY WITH FIELD CONDITION WILL VARY WITH FIELD CONDITION FIELD CUT SEALANT CONTINUOUS SEALANT APPLIED AT FASTENER LOCATIONS OUTSIDE CORNER TRIM F.I.P. INSULATION AS REQUIRED (BY OTHERS) HORIZONTAL SUPPORT SEALANT 3 4 " PHIL. PAN HEAD 8" O.C. INSIDE CORNER TRIM 1 4 " - 14 THROUGH FASTENERS W/ 1 1 8" BONDED WASHER (AS REQUIRED FOR WIND LOAD) INSIDE CORNER WITH PROFILED TRIM
15 SEALANT AT PANEL JOINT 1 4 " - 14 THROUGH FASTENER W/ WASHER SEALANT BOTH SIDES OF TRIM W/ MARRIAGE BEAD TO VERTICAL PANEL JOINT CONTINUOUS BUTYL SEALANT EXTERIOR CAP TRIM FRAMED OPENING DRIP FLASHING EXPOSED SEALANT DOOR/WINDOW FRAME, COMPONENTS AND ACCESSORIES NOTE: SEE DETAIL CI-TL AND CI-TL FOR TYPICAL TRIM LAP INSTRUCTIONS FRAMED OPENING HEAD W/ "DRIP EDGE"
16 FRAMED OPENING DOOR/WINDOW FRAME, COMPONENTS AND ACCESSORIES 1 4 " - 14 THROUGH FASTENER SEALANT BOTH SIDES OF TRIM INTERIOR CAP TRIM EXPOSED SEALANT EXTERIOR CAP TRIM NOTE: SEE DETAIL CI-TL AND CI-TL FOR TYPICAL TRIM LAP INSTRUCTIONS FRAMED OPENING TWO PIECE JAMB
17 FRAMED OPENING DOOR/WINDOW FRAME, ACCESSORIES AND WEATHER TIGHTNESS. FOLLOW COMPONENT MANUFACTURER INSTALLATION INSTRUCTIONS FOR PROPER INSTALLATION. FIELD BEND (AS REQUIRED) 1 4 " - 14 "LOW PROFILE" FASTENER (AS REQUIRED) 1 4 " - 14 THROUGH FASTENER SEALANT SEALANT EXPOSED SEALANT EXTERIOR CAP TRIM NOTE: SEE DETAIL CI-TL AND CI-TL FOR TYPICAL TRIM LAP INSTRUCTIONS FRAMED OPENING ONE PIECE JAMB
18 EXPOSED SEALANT SEALANT DOOR/WINDOW FRAME FIELD BEND (AS REQUIRED) SEALANT W/ MARRIAGE BEAD AT JOINT LOCATIONS EXTERIOR CAP TRIM 1 4 " - 14 "LOW PROFILE" FASTENER (AS REQUIRED) 1 4 " - 14 THROUGH FASTENER FRAMED OPENING SEALANT AT PANEL JOINT NOTE: SEE DETAIL CI-TL AND CI-TL FOR TYPICAL TRIM LAP INSTRUCTIONS FRAMED OPENING ONE PIECE SILL
19 SEALANT AT PANEL JOINT SEALANT BOTH SIDES OF TRIM W/ MARRIAGE BEAD TO VERTICAL PANEL JOINT 1 4 " - 14 THROUGH FASTENER 3 EXTERIOR CAP TRIM FRAMED OPENING 2 DRIP FLASHING EXPOSED SEALANT 1 FASTENER HEADER TRIM (OPTIONAL) TRIM INSTALLATION SEQUENCE: 1 INSTALL HEADER TRIM (OPTIONAL) & ALL APPLICABLE SEALANTS 2 INSTALL DRIP FLASHING & ALL APPLICABLE SEALANTS PRIOR TO INSTALLING THE PANEL AND THROUGH FASTENERS 3 INSTALL EXTERIOR CAP TRIM NOTE: SEE DETAIL CI-TL AND CI-TL FOR TYPICAL TRIM LAP INSTRUCTIONS OVERHEAD DOOR HEAD W/ DRIP EDGE
20 FASTENER FRAMED OPENING 1 4 " - 14 THROUGH FASTENER 1 JAMB TRIM (OPTIONAL) SEALANT 2 INTERIOR CAP TRIM EXPOSED SEALANT 3 EXTERIOR CAP TRIM TRIM INSTALLATION SEQUENCE: 1 INSTALL JAMB TRIM (OPTIONAL) & ALL APPLICABLE SEALANTS 2 INSTALL INTERIOR CAP TRIM & ALL APPLICABLE SEALANTS PRIOR TO INSTALLING THE PANEL AND THROUGH FASTENERS 3 INSTALL EXTERIOR CAP TRIM NOTE: SEE DETAIL CI-TL AND CI-TL FOR TYPICAL TRIM LAP INSTRUCTIONS OVERHEAD DOOR TWO-PIECE JAMB
21 RIB CLOSURE TRIM STACK TRIM FIELD DRILL OPTIONAL 3 8" WEEP HOLES AS REQUIRED STACK FLASHING 1 4 " - 14 THROUGH FASTENER (AS REQUIRED FOR WIND LOAD) SEALANT W/ MARRIAGE BEAD TO VERTICAL PANEL JOINT HORIZONTAL SUPPORT FASTEN AS REQUIRED SEALANT W/ MARRIAGE BEAD AT PANEL JOINT LOCATIONS RIB CLOSURE TRIM CONTINUOUS 3" X 3" ANGLE (GAUGE TO MATCH GIRT) 1 4 " - 14 THROUGH FASTENER (AS REQUIRED FOR WIND LOAD) SEALANT AT PANEL JOINT STACK JOINT W/ FLUSH TRIM
22 RIB CLOSURE TRIM STACK TRIM 1 4 " - 14 THROUGH FASTENER (AS REQUIRED FOR WIND LOAD) SEALANT W/ MARRIAGE BEAD TO VERTICAL PANEL JOINT HORIZONTAL SUPPORT FASTEN AS REQUIRED STACK FLASHING SEALANT W/ MARRIAGE BEAD AT PANEL JOINT LOCATIONS RIB CLOSURE TRIM CONTINUOUS 3" X 3" ANGLE (GAUGE TO MATCH GIRT) 1 4 " - 14 THROUGH FASTENER (AS REQUIRED FOR WIND LOAD) SEALANT AT PANEL JOINT STACK JOINT W/ PROFILED TRIM
23 SEALANT W/ MARRIAGE BEAD AT JOINT LOCATIONS PARAPET BLOCKING PARAPET CAP WRAP MEMBRANE ADHERE TO EXTERIOR PANEL FACE FASTENER TO PARAPET BACKER 1 4 " - 14 THROUGH FASTENER (AS REQUIRED FOR WIND LOAD) 900 SERIES FOAM CLOSURE W/ BUTYL TAPE TOP AND BOTTOM SEALANT AT PANEL JOINT MEMBRANE ROOF & PARAPET BACKER PARAPET WITH FLUSH TRIM
24 SEALANT W/ MARRIAGE BEAD AT JOINT LOCATIONS PARAPET BLOCKING PARAPET CAP WRAP MEMBRANE ADHERE TO EXTERIOR PANEL FACE FASTENER TO PARAPET BACKER 1 4 " - 14 THROUGH FASTENER (AS REQUIRED FOR WIND LOAD) 900 SERIES FOAM CLOSURE W/ BUTYL TAPE TOP AND BOTTOM SEALANT AT PANEL JOINT MEMBRANE ROOF & PARAPET BACKER PARAPET WITH PROFILED TRIM
25 REFER TO 900/1000 SERIES ROOF PANEL DETAILS FOR ADDITIONAL INFORMATION EAVE STRUT SEALANT W/ MARRIAGE BEAD AT JOINT LOCATIONS 1 4 " - 14 THROUGH FASTENERS W/ WASHER (AS REQUIRED FOR WIND LOAD) SEALANT AT PANEL JOINT FASTENER 900 FOAM CLOSURE SET IN BUTYL TAPE TOP AND BOTTOM LOW EAVE W/ GUTTER
26 REFER TO 900/1000 SERIES ROOF PANEL DETAILS FOR ADDITIONAL INFORMATION SHEETING OR RAKE ANGLE REQUIRED SEALANT W/ MARRIAGE BEAD TO AT PANEL JOINT LOCATIONS FASTENER 900 FOAM CLOSURE SET IN BUTYL TAPE TOP AND BOTTOM 1 4 " - 14 THROUGH FASTENERS W/ WASHER (AS REQUIRED FOR WIND LOAD) SEALANT AT PANEL JOINT RAKE
27 REFER TO 900/1000 SERIES ROOF PANEL DETAILS FOR ADDITIONAL INFORMATION EAVE STRUT SEALANT W/ MARRIAGE BEAD AT PANEL JOINT LOCATIONS FASTENER 900 FOAM CLOSURE SET IN BUTYL TAPE TOP AND BOTTOM 1 4 " - 14 THROUGH FASTENERS W/ WASHER (AS REQUIRED FOR WIND LOAD) SEALANT AT PANEL JOINT RAKE
28 (2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP MIN. 3" TRIM LAP TRIM END LAP
29 FIELD NOTCH HEM(S) AS REQUIRED MIN. 3" TRIM LAP (2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP TRIM LAP WITH HEM
30 (2) BEADS BUTYL SEALANT 8" LONG LAP STRIP NOM. 1 4 " GAP TRIM END LAP WITH LAP STRIP
31 FIELD NOTCH AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY SEALANT END DAM 2 INTERIOR HEAD TRIM WITH TABS BENT DOWN FIELD MITER AND OVERLAP TRIMS, POP RIVET AS NECESSARY INTERIOR CAP TRIM AT HEAD EXPOSED SEALANT EXTERIOR CAP TRIM AT HEAD 5 EXTERIOR HEAD TRIM W/ FIELD DRILL 3 8" Ø WEEP HOLES INTERIOR JAMB TRIM 1 SILL TRIM WITH TABS BENT UP 6 3 EXTERIOR CAP TRIM AT JAMB FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP 4 EXTERIOR JAMB TRIM FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP EXTERIOR CAP TRIM AT SILL FIELD MITER AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY TRIM INSTALLATION SEQUENCE: 1 INTERIOR JAMB TRIM 2 INTERIOR HEAD TRIM WITH TABS DOWN 3 SILL TRIM WITH TABS UP 4 EXTERIOR JAMB TRIM 5 EXTERIOR HEAD TRIM 6 EXTERIOR SEALANTS AS REQUIRED TRIM LAP AT FRAMED OPENING
400 SERIES VERTICAL INSTALLATION
CI-DS-01-400V CI-PJ-01-400V CI-PJ-02-400V CI-PJ-03-400V CI-BS-01-400V CI-BS-02-400V CI-BS-03-400V CI-BS-04-400V CI-BS-05-400V CI-OC-01-400V CI-OC-02-400V CI-IC-01-400V CI-IC-02-400V CI-FO-01-400V CI-FO-02-400V
More informationL:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET
KPV-DS-01-BRH KPV-PJ-01-BRH KPV-PJ-02-BRH KPV-PJ-03-BRH KPV-BS-01-BRH KPV-BS-02-BRH KPV-BS-03-BRH KPV-OC-01-BRH KPV-IC-01-BRH KPV-FO-01-BRH KPV-FO-02-BRH KPV-FO-03-BRH KPV-SJ-01-BRH KPV-PR-01-BRH KPV-LE-01-BRH
More informationTHESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.
FRKPV-DS-01-MTLH FRKPV-PJ-01-MTLH FRKPV-PJ-02-MTLH FRKPV-PJ-03-MTLH FRKPV-FS-01-MTLH FRKPV-FS-02-MTLH FRKPV-BS-01-MTLH FRKPV-BS-02-MTLH FRKPV-BS-03-MTLH FRKPV-BS-04-MTLH FRKPV-OC-01-MTLH FRKPV-IC-01-MTLH
More informationKS42 MF SERIES - HORIZONTAL INSTALLATION
CI-DS-01-KSMF H CI-PJ-01-KSMF H CI-PJ-02-KSMF H CI-PJ-03-KSMF H CI-PJ-04-KSMF H CI-PJ-05-KSMF H CI-PJ-06-KSMF H CI-PJ-07-KSMF H CI-PJ-08-KSMF H CI-PJ-09-KSMF H CI-PJ-10-KSMF H CI-PJ-11-KSMF H CI-PJ-12-KSMF
More informationDW VERTICAL INSTALLATION
AR-PJ-01-DW5V AR-PJ-02-DW5V AR-PJ-03-DW5V AR-PJ-04-DW5V AR-BS-01-DW5V AR-BS-02-DW5V AR-OC-01-DW5V AR-OC-02-DW5V AR-OC-03-DW5V AR-IC-01-DW5V AR-IC-02-DW5V AR-IC-03-DW5V AR-FO-01-DW5V AR-FO-02-DW5V AR-FO-03-DW5V
More informationTHESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.
KPV-DS-01-MTLH C & I DISCLAIMER KPV-PJ-01-MTLH EXPANDED PANEL JOINT KPV-PJ-02-MTLH ENGAGED PANEL JOINT KPV-PJ-03-MTLH INTERMEDIATE SUPPORT KPV-FS-01-MTLH MULTI-STORY FIRE STOPPING DETAIL KPV-FS-02-MTLH
More informationDW HORIZONTAL INSTALLATION
AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S
More informationMULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET
KPH-DS-01-MTLV KPH-PP-01-MTLV KPH-PP-02-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-FS-01-MTLV KPH-FS-02-MTLV KPH-FS-03-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV
More informationKS SERIES - VERTICAL INSTALLATION
CS-DS-01-KSV CS DISCLAIMER CS-PJ-01-KSV KS42SL EXPANDED PANEL JOINT CS-PJ-02-KSV KS42SL ENGAGED PANEL JOINT CS-PJ-03-KSV KS45SL EXPANDED PANEL JOINT CS-PJ-04-KSV KS45 FLAT ENGAGED PANEL JOINT CS-PJ-05-KSV
More information900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR
900 SERIES PANEL CI-DS-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-EL-01-900 CI-EL-02-900 CI-EL-03-900 CI-EL-04-900 CI-EL-05-900 CI-EL-06-900 CI-EL-07-900 CI-EL-08-900 CI-RD-01-900 CI-RD-02-900 CI-RD-03-900 CI-EV-01-900
More information~ ~ -
~----------------~ - METL DISCLAIMER: These details are based on industry accepted practices and provide a guideline for proper insulated metal panel and component installation. The location of vapor barriers
More informationTABLE OF CONTENTS A. PBR
TABLE OF CONTENTS A. PBR Panel 1. PBR Panel Architect/Engineer Information....................................... 2 2. PBR Panel UL 90 Requirements............................................... 3 3. PBR
More information40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)
http://www.sundancesupply.com 40mm Thermoclick Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) U-Profile 12' Lengths $39 Out System offers a complete set of extrusions and accessories
More informationSEAL PLATE SP4413 VERTICAL SP4414 1"[25] VERT. PANEL JTS. 1/2"[13] INTERM. SPLICES DESIGN LOADS AND SLAB EDGE DISTANCES. 1 2 NOM.
3 COL 5 16GA. ANGLE SP4413 VERTICAL SEE SUPPORT DRAINGS 1 7/16 SEAL PLATE @ VERT. JNT 1/2 [13] Ă DETAILER NOTE OPTIONAL INSULATION HEN REQUIRED. OF SEAL PLATE PANEL MODULE 2.500 FROM SHELF OF TR. TO TOP
More informationRECOMMENDED INSTALLATION PROCEDURE LEVEL 3
Step 1. Install Sill Flashing Product: 9" or 12" RainBuster #440 SubZero Flashing Tape 1.A Flashing Length = (Rough Opening Width) + 12" 1.B Install sill flashing flush with the sill of the rough opening.
More informationTABLE OF CONTENTS A-1
TABLE OF CONTENTS PAGE NUMBER: DETAIL DESCRIPTION A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1...GENERAL INFORMATION C-1...EAVE DRIP DETAIL C-2...EAVE DRIP with GUTTER DETAIL C-3 & C-4...FIXED RIDGE
More informationREGAL. Installation Manual
REGAL Installation Manual General Information The details shown on the following pages are suggestions or guidelines for installing the Regal system. The installation details shown here are proven methods
More informationMAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24" O.C. ALL FASTENERS TO PENETRATE WOOD 3/4" MIN. AND METAL FRAMING 1/2" MIN.
PLYWOOD SHEATHING DMI SOFFIT PANEL #10-13 GP PANCAKE HEAD (JC) - J CLOSURE (LC) - L CLOSURE #9-15 X 1 1/2" WOODZAC GP APPROVED MOISTURE BARRIER SOFFIT TO WALL PANEL WPRP-H-01-00 APPROVED MOISTURE BARRIER
More informationGLOSSARY OF TERMS SECTION 8
GLOSSARY OF TERMS SECTION 8 Anchor Bolt Angle Base Plate Bay Blocking CCB Centerline Chord Cladding Clip Closure Strip An A-307 steel bolt embedded in the concrete footing to anchor the base plate of the
More informationWESTERN WAVE Panel. Horizontal Installation and Technical Information
WESTERN WAVE Panel Horizontal Installation and Technical Information Western States Western Wave Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page
More informationWESTERN WAVE Panel. Vertical Installation and Technical Information
WESTERN WAVE Panel Vertical Installation and Technical Information Western States Western Wave Wall and Soffit Panels (Vertical) Installation, Flashings & Shop Drawing Detail Guide Section Notes to Designer
More informationConstruction details: Master-C type profiles and joints:
Construction details: Master-C type profiles and joints: Master-C 3g 32 mm. (1 1/4 ) 1000 mm. (39 3/8 ) outer face inner face 10.5 fixing details: sealing washers shall be installed through a 2-3/8 x 1-9/16
More informationSpeedDeck. Fixing and Handling Guide
SpeedDeck Section 1 Delivery/Storing On Site/Handling l SpeedDeck is factory or on-site manufactured. l Straight SpeedDeck bundles are a maximum 1 tonne, sheets nestled and banded with polypropylene or
More informationULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS
ULTRA WINDOW & DOOR S AND RECEIVERS INSTALLATION INSTRUCTIONS! CAUTION: *REMEMBER SAFETY FIRST* Proper Eye and! Hearing Protection must always be worn during installation of all window and door products.
More informationInsulated Panels North America. Installation Guide KarrierPanel Wall System
Insulated Panels North America Installation Guide KarrierPanel Wall System Installation Guide KarrierPanel Wall System Disclaimer This installation guide is only to be used in conjunction with panel installation
More informationTremLock T-138 INSTALLATION MANUAL T-138 www.tremcoroofing.com 3735 Green Road Beachwood, Ohio 44122 1.800.852.6013 50 Beth Nealson Drive Toronto, Ontario M4H 1M6 1.800.668.9879 7241 6/8/18 TABLE OF CONTENTS
More informationThermoSpan EPS. Metalcraft COMMERCIAL ROOFING CREPS. Insulated Panel Systems DETAIL LIST
ThermoSpan EPS DETAIL LIST 00 / 15 COVER SHEET 01 / 15 RIDGE DETAIL 02 / 15 HEAD FLASHING DETAIL 03 / 15 EAVES GUTTER DETAIL 04 / 15 INSULATED GUTTER 05 / 15 INSULATED BOX GUTTER 06 / 15 BARGE CAPPING
More informationPROVEN DEPENDABLE SUSTAINABLE
B/SOFFIT FP CLIP 24" O.C. MAX SECTION "A-A" PLYWOOD SHEATHING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. A B/SOFFIT A (JC) - J CLOSURE DMI WALL PANEL PLYWOOD SHEATHING SOFFIT TO WALL PANEL FR10-V-01-00 B/SOFFIT
More informationGIRTS ON BACK OF BUILDING
GIRTS ON BACK OF BUILDING ALL GIRTS ARE 1 1/2 SQUARE TUBE. GIRT LENGTHS FOR 12, 20, 24, AND 30 WIDE BUILDINGS: ON 12 WIDE BUILDINGS GIRTS ARE 67 3/4 LONG ON 20 WIDE BUILDINGS GIRTS ARE 56 3/4 LONG ON 24
More informationDMI FR1511 PANEL (JC) - J CLOSURE DMI WALL PANEL SOFFIT TO WALL PANEL PROVEN DEPENDABLE SUSTAINABLE METAL ENVELOPE SYSTEMS SINCE 1988
FP CLIP 24" O.C. MAX B/SOFFIT 5 1/2" SECTION "A-A" PLYWOOD SHEATHING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. A B/SOFFIT A (JC) - J CLOSURE DMI WALL PANEL PLYWOOD SHEATHING SOFFIT TO WALL PANEL FR15-V-01-00
More informationAll Window Installation Instruction
1 All Window Installation Instruction Hurd Window Installation Instructions for Nail Fin & Wood Brick Mould Units Nail Fin Windows See Pages 2-11 Wood Brick Mould Windows See Pages 2-6, 8 & 12BM - 14BM
More informationSteel Roofing & Siding INSTALLATION GUIDE
Steel Roofing & Siding INSTALLATION GUIDE Your Authorized Dealer is: WASHINGTON Auburn (800) 700-7228 WASHINGTON Spokane (866) 321-5954 www.nuraymetals.com CALIFORNIA Redlands (800) 806-8729 CONTENTS BEFORE
More informationThe Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA
TRS 9 35MM 78MM 150MM 78MM THICKNESS END SPAN INTERNAL SPAN MINIMUM PITCH 0.55MM 2.30M 3.20M 3 DESCRIPTION TRS 9 profile is designed for commercial and industrial roofing. The profile is suitable for low
More informationTuff-Rib Install Guide
Install Guide bestbuymetalroof.com Page 2 of 27 Page 3 of 27 1. Page 4 2. a. Installation Guide b. Panel Squaring Pages 5, 6 Pages 7, 8 3. Pages 9, 10 4. a. Fascia (optional) b. Eave / 1.5x3.5 Angle c.
More informationBest Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.
Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications. EXTERIOR INSULATION & FINISH SYSTEM CONSTRUCTION Data Published Courtesy
More informationVENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4
ROOF PANEL GABLE FLASHING FASTENER @ 24" C/C MAX. ROOF PURLIN BUTYL SEALANT TAPE FLASH AB-1, AB-2, AB-3, OR AB-4 FASTENER @ EVERY MAJOR RIB OR 12" C/C MAX. F-J TRIM FABRAL ALUMINUM SOFFIT FASTENER 24"
More informationTable of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection...
Table of Contents Section Page Notes to Designer/User... 2-3 Map of Typical Roof Conditions... 4 Fastener Placement... 5 Fastener Selection... 6 Ridge/Hip Flashing... 7 Valley Flashing... 8 Eave Flashings...
More informationForceField Air & Water Barrier System. installation instructions
ForceField Air & Water Barrier System installation instructions Protection and Performance inside and out The ForceField air and water barrier system consists of engineered wood sheathing panels laminated
More informationKocked Down with Ends Assembled
Installation Instructions for Quarter Round (QR) Kocked Down with Ends Assembled Note: Prior to starting Installation, check unit/parts for damage. Please read entire Installation Instructions & review
More informationCFDTT-01. Control Joint Study (General)
Trim Method Classic Method Notes: Control joints are required and should be located by the designer at the following locations on the construction documents: 144 sf (13.4 sm) is the maximum overall area
More informationAluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement
Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement 1 Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement The following instructions are a supplement
More informationeco-shake INSTALLATION INSTRUCTION
1 eco-shake INSTALLATION INSTRUCTION NOTE: Shuffling the eco-shakes during installation may be necessary to obtain a uniform color throughout the roof. Due to the natural wood content in the ecoshakes,
More informationTABLE OF CONTENTS A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION
TABLE OF CONTENTS PAGE NUMBER: DETAIL DESCRIPTION A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION MATRIX DETAILS C-1...FASCIA/SOFFIT DETAIL with ANGLE C-2...BUILDING/SOFFIT
More informationINSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS
2008 Pella Corporation Part Number: 803V0101 INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS Installation Instructions for Typical Wood Frame Construction. These instructions were developed
More informationFlushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide
Flushglaze 4500 For Framed Openings and Horizontal Panels Window System Installation Guide January 2017 BENCHMRK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels
More informationSTEVE ENNIS ARCHITECT 1108 EAST JACKSON STREET MEDFORD, OREGON 97504
ATTACH TO STRUC- TURE ABOVE 1/8"Ø BOLT W/ LOCKING NUT #12 WIRE TIE IN PLANE EACH TEE ANGLED 45 FROM HORIZ ATTACH 2" FROM INTERSECTION COMPRESSION POST LOCATE WITHIN 2" OF TEE INTERSECTION SIZE STRUTS FOR
More informationA P P L I C A T I O N I N S T R U C T I O N S
1 2 3 General Instructions NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE
More informationC.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit
Horizontal battens between verticals at soffit 2 C.04 600 600 600 600 Cavity batten at 600 mm centres 1 C.03 Batten fixing points 1 C.04 1 C.07 1 C.12 1 C.13 1 C.14 Meter Box Window 1 C.08 1 C.09 800 800
More informationEkoroof LiteTile Dimensions
Ekoroof LiteTile Dimensions 7 3 3.5 Height 40 Width 20 Length Weight per Panel: 3 kg / 6.61 lbs 2 2 Area per panel 800 in / 5.55 ft 2 Panels per Square: 20 (including overlap, for a 100 ft covered area)
More informationSG-30 A P P L I C A T I O N I N S T R U C T I O N S. Directions For Application
1 2 3 General Instructions NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE
More informationWEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS
CORE WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS Proper Window & Door Flashing Although all possible measures have been taken to insure the accuracy of the material presented,
More informationAPRON FLASHING NOTES: SHEET METAL APRON FLASHING WITH HEMMED EDGE RAGGLE SEALANT UNDERLAYMENT TURNED UP WALL
SHEET METAL APRON FLASHING WITH HEMMED EDGE SEALANT SHEET METAL COUNTERFLASHING (SEE NOTE No.1) RAGGLE UNDERLAYMENT TURNED UP WALL SHEET METAL STEP FLASHING SOLDER OR SEAL CORNERS ASPHALT SHINGLES NOTES:
More informationRECOMMENDED INSTALLATION PROCEDURE LEVEL 3
45 45 6 6 Step 1. Modify Weather Resistive Barrier 1.A Cut the weather resistive barrier flush to the recessed opening (per diagram). Remove the cut away weather resistive barrier, exposing recessed opening
More informationFinesse Profiles. Nailstrip
Installation Details Profile and Lap Detail 265/465 38mm NAILSTRIP *other widths available CD GRADE PLYWOOD 19mm STRUCTURE SILICONE * MIN 20mm VENTILATION GAP * WHEN ROOF PITCH IS UNDER 7.5 OR TOTAL COMBINED
More informationBARRELL VAULT BATTENLESS
i BARRELL VAULT BATTENLESS INSTALLATION GUIDE INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Barrel Vault battenless
More informationTYPICAL FRAMING AND STITCH FASTENER PATTERNS FOR MAX-RIB PANELS
TYPICAL AND PATTERNS FOR MAX-RIB S MAX-RIB (PATTERN #1) @ 1'-8" O.C. (MAX.) ROLL TAPE SEALANT @ SEAMS MAX-RIB @ 1'-8" O.C. (MAX.) ROLL TAPE SEALANT @ SEAMS MAX-RIB TRIM (PATTERN #3) NOTE: TAPE SEALANT
More informationwestern window systems westernwindowsystems.com installation instructions non-pocket 2-1/4 panels
series 2600 multi-slide non-pocket 2-1/4 panels windowsystems.com windowsystems.com movement, which can cause warping and other problems. Frame kit components: Each door will have a head assembly, a threshold
More informationTable of Contents Light Gauge Metal Roof & Wall Panels
Table of Contents Light Gauge Metal Roof & Wall Panels Installation Guide for Delta Rib, Nor-Clad, Strata Rib & 2-1/2 Corrugated Introduction Important Notice Notes: April 2008 Minimum Recommended Tools
More informationRead guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.
Installation Guide for E-Series/Eagle High-Performance Mullion Windows with LVL Reinforcement and Installed Using Type B Clips Thank you for choosing Andersen. Instructions are for typical, new wood-framed
More informationTuff Rib Panel Installation Specifications
Tuff Rib Panel Installation Specifications ROOF APPLICATION: Roof slope must be a minimum of a 2/12 pitch to use this product. For slopes lower than a 3/12 pitch, lap sealant is suggested on the side laps
More informationDear Contractor, I am glad that you are interested in our window rebate program.
Dear Contractor, I am glad that you are interested in our window rebate program. I have included three documents with this letter. One is our form to indicate your intention to participate in the program.
More informationFlashing Materials. Rough Opening Preparation
Installation Instructions for CertainTeed New Construction Windows Handling vinyl windows CAUTION: Always store vinyl windows and doors in an upright position on a slight angle. Never lay them flat or
More informationFold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE
Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE This instruction guide provides the minimum recommended procedures to correctly prepare the rough opening, install a fold-a-way patio door unit and apply
More informationWINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS
WINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS These instructions were tested developed for replacing windows in wood-frame wall construction systems
More informationInspire Aledora Slate Application Guidelines
July 2014 Inspire Aledora Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry bar,
More informationDIRECTIONS FOR APPLICATION
Instructions 1 General NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE DIRECTIONS
More informationHow To Install Windows: Nail-Fin Application
How To Install Windows: Nail-Fin Application Required Tools & Materials: Materials: 1 3/4" galvanized roofing nails. Nails must penetrate at least 1" into framing For mulled and/or DP50 or above units:
More informationINSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GLOSSARY ROUGH OPENINGS
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions
More informationPocket Door Installation Instructions
Installation Instructions Before getting started: Read instructions thoroughly. Be sure that you have the necessary tools and materials before starting the installation. Consult your local building code
More informationALPINE TRAY. To get the best from this product please follow these recommendations.
F I X I N G D E TA I L S ALPINE TRAY The standing seam roofing profile is designed to withstand some of New Zealand s harshest weather in our toughest environments. To get the best from this product please
More informationINSTALLATION INSTRUCTIONS LS X 12-2 X 7 1/2 FRAME LOAFING SHED
INSTALLATION INSTRUCTIONS LS-12 12 X 12-2 X 7 1/2 FRAME ACTUAL FRAME BASE SIZE: 12 X 12-2 LOAFING SHED Our unique assembly process quickly transforms the individual pieces into a finished structure that
More informationNEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING
NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS Reference Guide 0.1 GENERAL 0.1 Reference Guide 0.2 Index 0.3 Disclaimer & Limitations 0.4 General Notes
More information2 ½ Corrugated Panel Installation Specifications
2 ½ Corrugated Panel Installation Specifications ROOF APPLICATION: Roof slope must be a minimum of a 2/12 pitch to use this product. When using this product butyl lap sealant is recommended for all slopes.
More informationInstallation of Fiberglass Windows
Installation of Fiberglass Windows Before you begin please read and understand these installation instructions. The following installation instructions are recommended by Norwood and failure to follow
More informationINSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions
More informationFlexLoc. Technical/Installation Information
Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE FLEXLOC PANELS. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES BEFORE
More information(773) INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GL OSSARY ROUGH OPENINGS
Thank you for selecting C l i m a t e G u a r d products. Attached are our recommended installation instructions for Vinyl windows with an integral (2400-02) will not affect application of the ClimateGuard
More informationCROSSBAR RAFTER ISOMETRIC
Super Sky Products' typical glazing system consists of glass panels or "lites" which are attached to the main framing members using extruded aluminum "retainers" or "pressure plates". These retainers are
More informationA REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS
WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME
More informationINSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN
MINNEAPOLIS, MN 2-0- 2-- General Notes Abbreviations Deviations from Architectural Specifications Deviations from Architectural Drawings ALUM. = ALUMINUM B.O. = BY OTHERS CONT. = CONTINUOUS. = CLEARANCE
More informationSpeedZip. Fixing and Handling Guide
Section 1 Delivery/Storing On Site/Handling l SpeedZip is factory or on-site manufactured. l Straight SpeedZip bundles are a maximum 1 tonne, 2 No. sheets nestled and then and placed face to face, banded
More informationPBR Panel Installation Specifications
4906 St. Stephens Rd. 5780 Hwy 90 W Eight Mile, Al 36613 Theodore, AL 36590 251 456 2254 251 653 1550 251 457 2254(F) 251 653 1514(F) PBR Panel Installation Specifications ROOF APPLICATION: Roof slope
More informationCONTENTS. Transitions Board and Batten Vertical Installation... 10,11
INSTALLATION MANUAL CONTENTS Important Notes... 2-4 Weather Protective Barriers... 2 Storage and Transportation... 2 Tools and Equipment... 2 Fastener Choices... 3 Wall Preparation... 3,4 Flashing... 4
More informationInspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square
December 2017 Classic Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry bar,
More informationINSTALLATION INSTRUCTIONS LS X 12-2 X 7 1/2 FRAME LOAFING SHED
INSTALLATION INSTRUCTIONS LS-30 30 X 12-2 X 7 1/2 FRAME ACTUAL FRAME BASE SIZE: 30 X 12-2 LOAFING SHED Our unique assembly process quickly transforms the individual pieces into a finished structure that
More informationMULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION
MULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION TOOLS AND SUPPLIES 1 TOOLS CHECK LIST 1. laser level 2. hammer 3. pry bars 4. ladders 5. utility knife 6. screw gun 7. applicator foam gun 8. "j"
More informationBest Buy Metals Toll Free / Phone / Fax
DETAIL MANUAL for Vertical Seam Best Buy Metals Toll Free 1-800-728-4010 / Phone 423-479-6382 / Fax 423-728-3066 www.bestbuymetals.com Vertical Seam Roofing Panels Fig. 2 Vertical Seam Has 1-3/4" high
More informationWindows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Picture Frame Method Revised 10/24/2016
Windows Installed into Walls with Polyiso and Wood Framing Installation Instructions Picture Frame Method Revised 10/24/2016 Background There are many acceptable ways to mount and detail windows for support
More information14000 I/O Series Flush Glaze. Fabrication and Installation Instructions
14000 I/O Series Flush Glaze Fabrication and Installation Instructions Last saved on 12/18/2009 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...4 ACCESSORIES...5 OVERVIEW...6
More informationCOMPOSITE SIDING INSTALLATION GUIDE
CENTURY HOME LIVING COMPOSITE SIDING INSTALLATION GUIDE Read all instructions prior to installing any siding product. Failure to install and finish this product in accordance with all local building codes,
More informationMetroCOTTAGE Shingle
Batten-less Installation Sept. 14, 2017 INSTALLATION WARNING! These install details are provided to demonstrate a recommended installation method for Metro Roof panels and accessories. used in the United
More informationInstallation Instruction 3-D Model 3D 03/01/17. 0 Flush Siding Horizontal System N/C WPS, Inc.
I B D L K C E G M F A H J Installation Instruction 3-D Model 3D 03/01/17 Detail: System Type: Scale: Drawn By: 0 Flush Siding Horizontal System N/C WPS, Inc. Wall Panel System, Inc. 15/16" 1 1/4" Bottom
More informationINSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG
2008 Pella Corporation Part Number: 80ED0101 INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG Instrucciones en español
More informationSERIES 300 SINGLE HUNG WINDOW INSTALLATION
IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS
More information4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside.
Effective Date: 10/1/2017 Tools Needed Kit Contents Hardware Kit Safety Glasses Cordless drill Phillips screw bit Two-step drill bit (3/8-1/8 ) utility knife Interior Mullion Exterior Mullion Cover clamps
More informationUC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER
CAMPUS STANDARDS APPENDIX I UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 WINDOW INSTALLATION SEQUENCING GUIDE Issued By: Pyatok Architects and Allana Buick &
More informationGENERAL INSTALLATION GUIDELINES
1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 9/29/2017 Installation Guideline Disclaimer This document contains general installation
More informationINSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.
for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) Thank you for selecting JELD -WEN products. Attached are JELD-WEN s recommended installation instructions for metal clad wood windows
More informationGENERAL INSTALLATION GUIDELINES
1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 08/31/2018 Installation Guideline Disclaimer This document contains general installation
More informationWindows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016
Windows Installed into Walls with Polyiso and Wood Framing Installation Instructions Standard Method Revised 10/24/2016 Background There are many acceptable ways to mount and detail windows for support
More information