Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.
|
|
- Irene Dorthy Thomas
- 5 years ago
- Views:
Transcription
1 Plank joint 600mm stud crs 600mm 600mm 600mm Horizontal Structural Timber Cavity atten 50x20mm H3.1 atten fixing points 800mm 800mm 300mm 800mm Max. Nog spacing 50mm All intermediate battens to be 50x20mm structural timber. Refer to fixing specification 50mm Plank overhang Structural SG8 Timber Cavity atten (50x20mm for butt joint, 70x20mm for express joint) H3.1, fixed over breather type building underlay & framing with 65x2.8mm RounDrive ring shank galv nails or 60x2.8mm Galv Jolt Head nails at 300mm centres staggered 12mm either side of centre line GC Vermin proof vent strip or similar Polypropylene tape at 300mm crs fixed horizontally and drawn taut GC Stratum atten Fixing setout Note: No horizontal Structural timber Cavity battens required at nogs GC Stratum and Stratum Duo atten Fixing Setout NO. A4 ST-01
2 600mm stud crs 600mm 600mm 600mm 3mm max gap butt joint OR 16mm max gap express joint 800mm 800mm 800mm Max. Nog spacing 75mm 50mm Typical 12mm 12mm All intermediate battens to be 50x20mm structural timber. Refer to fixing specification 50mm Plank overhang 50mm 30 x 1.6mm C Series Stainless Steel rad face fixed fix to each stud 50mm from base of board. 30 x 1.6mm C Series Stainless Steel rad concealed fix to each stud Structural SG8 Timber Cavity atten (50x20mm for butt joint, 70x20mm for express joint) H3.1, fixed over breather type building underlay & framing with 65x2.8mm RounDrive ring shank galv nails or 60x2.8mm Galv Jolt Head nails at 300mm centres staggered 12mm either side of centre line GC Stratum Fixing setout GC Vermin proof vent strip or similar. Ensure tight fit between battens Note: Polypropylene tape omitted for clarity Stratum Fixing options: 30 x 1.6mm C Series Stainless steel brad GC Stratum and Stratum Duo Stratum Fixing Setout NO. A4 ST-02
3 Cavity atten Note: Stratum adhered to batten with cont. 6mm bead of ostik seal 'N' Flex FC 30x1.6mm C Series Stainless Steel rad GC Stratum with all cut edges sealed with GC edge sealer or similar before fixing H3.1 treated SG8 timber cavity batten Durabarrier or approved breather type building underlay stud 65x2.8mm Roundrive ring shank nail at 300mm centres staggered 12mm ether side of centre line GC Stratum and Stratum Duo Intermediate Stud Fixing Cavity Construction NO. ST-03
4 Cavity atten Note: 12mm 12mm 3mm max gap. ostik Seal 'N' Flex FC 30x1.6mm C Series Stainless Steel rad GC Stratum with all cut edges sealed with GC edge sealer or similar before fixing Stratum adhered to batten with cont. 6mm bead of ostik Seal 'N' Flex FC to each plank Durabarrier or approved breather type building underlay stud 50x20mm vertical timber cavity batten. H3.1 treated SG8 timber 65x2.8mm Roundrive ring shank galv nail at 300mm centres. Fixings to be staggered 12mm either side of centre line GC Stratum and Stratum Duo Vertical Joint NO. ST-04
5 Cavity atten Note: 12mm 12mm 16mm max gap. 2-3mm of ostik Safe Seal. 30x1.6mm C Series Stainless Steel rad GC Stratum with all cut edges sealed with GC edge sealer or similar before fixing Stratum adhered to batten with cont. 6mm bead of ostik Seal 'N' Flex FC to each plank Durabarrier or approved breather type building underlay stud 70x20mm vertical timber cavity batten. H3.1 treated SG8 timber 65x2.8mm Roundrive ring shank galv nail at 300mm centres. Fixings to be staggered 12mm either side of centre line GC Stratum and Stratum Duo Alternative Express Vertical Joint Cavity Construction NO. ST-05
6 Cavity atten Note: 30x1.6mm C Series Stainless Steel rad breather type building underlay Timber framing GC Stratum with all cut edges sealed with GC edge sealer or similar before fixing 50 ~ 20 to 45 cut to batten ends to ensure that moisture runs to exterior. ~ Prime the cut ends with dulux Acraprime 501 /1 acrylic sealer or Resene Quick Dry x2.8mm Roundrive ring shank nail at 300mm centres staggered 12mm either side of centre line H3.1 treated SG8 timber cavity batten GC Stratum and Stratum Duo Joining of Structural Cavity atten NO. ST-06
7 breather type building underlay 65x2.8mm Roundrive ring shank nail. GC Stratum with all cut edges sealed with GC edge sealer or similar before fixing 30x1.6mm C Series Stainless Steel rad Timber framing 15mm 50mm Express joints only - vertical 6mm bead of ostik Seal 'N' Flex FC in laps at board ends H3.1 treated SG8 timber cavity batten Cavity atten Note: layout for batten sizes, types, spacing's & fixings. GC Stratum and Stratum Duo Horizontal Joint NO. A4 ST-07
8 Cavity atten Note: layout for batten sizes, types, spacing's & fixings. Mid floor flooring - finish 10mm back from external wall framing. breather type building underlay. Stratum adhered to batten with cont. 6mm bead of ostik Seal 'N' Flex FC (not shown for clarity). Flexible flashing tape or building underlay lapped over flashing upstand. Continuous Vent strip or similar set to give 15mm min drip edge to cladding. Mid floor structure 5 35 min cover Aluminium inter-storey "Z" flashing with 15 slope. 35 min cover 30x1.6mm C Series Stainless Steel rad 65x2.8mm Roundrive ring shank galv nail at 300mm centres H3.1 treated timber SG8 cavity batten GC Stratum with all cut sheet edges sealed before fixing. Note: Drained joints must be used to limit cavities to maximum 2 stories or 7m in height in accordance with NZC acceptable solution E2/AS1 Paragraph GC Stratum and Stratum Duo Interstorey Drainage Detail NO. ST-08
9 Cavity atten Note: H3.1 treated SG8 timber cavity batten breather type building underlay 30x1.6mm C Series Stainless Steel rad Timber ottom plate on D.P.C. GC Stratum with all cut edges sealed before fixing. Apply cont. 6mm bead of ostik Seal 'N' Flex FC adhesive sealant (not shown for clarity). GC Vermin proof vent strip or similar. Concrete Slab or block work 15 50min 100mm min to permanent paving or 175mm min to unprotected ground Finished ground level. GC Stratum and Stratum Duo Foundation Detail NO. ST-09
10 Cavity atten Note: layout for batten sizes, types, spacing's & fixings. H3.1 treated SG8 timber cavity batten breather type building underlay 30x1.6mm C Series Stainless Steel rad Timber ottom plate on D.P.C. (concrete floor only) GC Vermin proof vent strip or similar. Waterproof decking membrane to carry up behind building underlay past wall framing bottom plate. Floor structure 15 Corner fillet GC Stratum with all cut sheet edges sealed before fixing. 50mm min 50mm 100mm min 150 mm membrane upstand Enclosed deck structure GC Stratum and Stratum Duo Enclosed Deck Detail NO. ST-10
11 breather type building underlay continuous around corner GC Stratum with all cut edges sealed before fixing Stratum adhered to flashing with cont. 6mm bead of ostik Seal 'N' Flex FC 30x1.6mm C Series Stainless Steel rad GC Internal Aluminium Corner flashing Stratum adhered to flashing with cont. 6mm bead of ostik Seal 'N' Flex FC H3.1 treated SG8 timber cavity batten 10mm min 65x2.8mm Roundrive ring shank galv nail at 300mm centres staggered 12mm either side of centre line Timber framing as indicated Cavity atten Note: layout for batten sizes, types, spacing's & fixings. GC Stratum and Stratum Duo Internal Corner Aluminium Trim NO. A4 ST-11
12 breather type building underlay continuous around corner GC Stratum with all cut edges sealed before fixing Stratum adhered to flashing with cont. 6mm bead of ostik Seal 'N' Flex FC 30x1.6mm C Series Stainless Steel rad Join mitre cut boards with ostik Seal 'N' Flex FC. Cut off excess once sealant has cured Stratum adhered to flashing with cont. 6mm bead of ostik Seal 'N' Flex FC H3.1 treated SG8 timber cavity batten 10mm min 90x galv or PVC flashing (100mm wide each side) 65x2.8mm Roundrive ring shank galv nail. Timber framing as indicated Note: Join mitre cut boards with ostik Seal n Flex FC. Push hard together and cut off excess once cured Cavity atten Note: layout for batten sizes, types, spacing's & fixings. GC Stratum and Stratum Duo Internal Corner Mitre NO. A4 ST-12
13 GC Stratum with all cut edges sealed before fixing Durabarrier or approved breather type building underlay continuous around corner Timber framing. H3.1 treated SG8 timber cavity batten 65x2.8mm Roundrive ring shank galv nail. Stratum adhered to flashing with cont. 6mm bead of ostik Seal 'N' Flex FC 10mm min GC External Aluminium Corner flashing Stratum adhered to flashing with cont. 6mm bead of ostik Seal 'N' Flex FC 30x1.6mm C Series Stainless Steel rad Cavity atten Note: layout for batten sizes, types, spacing's & fixings. GC Stratum and Stratum Duo External Corner Aluminium Trim NO. A4 ST-13
14 GC Stratum with all cut edges sealed before fixing Durabarrier or approved breather type building underlay continuous around corner Timber framing. H3.1 treated SG8 timber cavity batten 65x2.8mm Roundrive ring shank galv nail. Stratum adhered to flashing with cont. 6mm bead of ostik Seal 'N' Flex FC 30x1.6mm C Series Stainless Steel rad 10mm min 90x Galv or PVC flashing (100mm wide each side) Join mitre cut boards with ostik Seal 'N' Flex FC. Cut off excess once sealant has cured Note: Join mitre cut boards with ostik Seal n Flex FC. Push hard together and cut off excess once cured Stratum adhered to flashing with cont. 6mm bead of ostik Seal 'N' Flex FC 30x1.6mm C Series Stainless Steel rad Cavity atten Note: layout for batten sizes, types, spacing's & fixings. GC Stratum and Stratum Duo External Corner Mitre NO. A4 ST-14
15 Cavity atten Note: H3.1 treated timber cavity batten. GC Stratum with all cut edges sealed with GC edge sealer or similar before fixing. breather type building underlay flexible flashing tape to opening corners. Timber framing. 35mm min flashing cover. Temporary timber packer removed after fixing. Air seal over backing rod. 7.5mm min 35mm min 10mm min 15mm min 5mm gap Apply cont. 6mm bead of ostik Seal 'N' Flex FC adhesive sealant (not shown for clarity). GC Vermin proof vent strip or similar. Additional layer of flexible flashing tape or building underlay lapped over head flashing. PC Aluminium head flashing with 15 fall with stop ends. PC Aluminium window joinery. Note where Durabarrier is used flashing tape must be applied to the entire opening For wind exposures Very High and above, sealant to be installed between underside of head flashing and top edge of window head flange GC Stratum and Stratum Duo Window Head Detail NO. ST-15
16 Cavity atten Note: Durabarrier or building underlay and flexible flashing tape. Flexible flashing tape to be continuous along sill, 100mm min. up each jamb and 50mm onto face of building underlay. Air seal over backing rod. Timber framing. Durabarrier or approved breather type building underlay H3.1 timber packer. 7.5mm Min. H3.1 treated timber cavity batten GC Stratum with all cut sheet edges sealed before fixing. Stratum adhered to batten with cont. 6mm bead of ostik Seal 'N' Flex FC (not shown for clarity). Foam seal tightly finished against J flashing 20mm 10mm min Cover Aluminium window joinery. GC J flashing Line of head flashing over. 10mm Min cover to Stratum by aluminium window joinery. 20mm Min overhang of head flashing. Note. Where Durabarrier is used flashing tape must be applied to the entire opening GC Stratum and Stratum Duo Window Jamb Detail NO. ST-16
17 Cavity atten Note: Aluminium window joinery. 7.5mm Min. H3.1 timber packer. Air seal over backing rod. Durabarrier or building underlay and flexible flashing tape. Flexible flashing tape to be continuous along sill, 100mm min. up each jamb and 50mm onto face of building underlay. 8mm Min cover to Stratum by aluminium window joinery. Compressible foam seal tightly finished against cladding or ostik Seal 'N' Flex sealant. Sill support bar. Stratum adhered to batten with cont. 6mm bead of ostik Seal 'N' Flex FC (not shown for clarity). GC Stratum with all cut sheet edges sealed before fixing. breather type building underlay. H3.1 treated SG8 timber cavity batten Note. Where Durabarrier is used flashing tape must be applied to the entire opening GC Stratum and Stratum Duo Window Sill Detail NO. ST-17
18 Cavity atten Note: Fold ends of head flashing to form stop ends Flashing tape over wall underlay fitted around corner as shown breather type building underlay flexible flashing tape to corners. H3.1 treated SG8 timber cavity batten. GC Stratum with all cut edges sealed with GC edge sealer or similar before fixing. Flashing tape over flashing (alternatively use extra layer of wall underlay) Timber framing. H3.1 treated SG8 timber cavity batten. GC Vermin proof vent strip or similar. Head flashing with 15 min slope 5mm min gap below Stratum Cut head flashing to continue past window opening Timber lintel Note where Durabarrier is used flashing tape must be applied to the entire opening GC Stratum and Stratum Duo Window Head/Jamb Junction Detail NO. ST-18
19 Cavity atten Note: 50mm min lap 100mm min lap 50mm min lap Flashing tape over wall underlay full width of opening Window support bar H3.1 treated SG8 timber cavity batten. GC Stratum with all cut edges sealed with GC edge sealer or similar before fixing. breather type building underlay H3.1 treated SG8 timber cavity batten. Note where Durabarrier is used flashing tape must be applied to the entire opening GC Stratum and Stratum Duo Window Sill/Jamb Junction Detail NO. ST-19
20 Cavity atten Note: Timber framing. H3.1 treated timber packer -continuous. Nog - offset to block airflow into roof space. 12 mm Durasheet soffit lining on H1.2 framing. 30x1.6mm C Series Stainless Steel rad H3.2 timber scotia breather type building underlay. GC Stratum with all cut sheet edges sealed before fixing. H3.1 treated SG8 timber cavity batten Scotia option Timber framing. H3.1 treated timber packer -continuous. Polythene bond breaker tape. Nog - offset to block airflow into roof space. 12 mm Durasheet soffit lining on H1.2 framing. 30x1.6mm C Series Stainless Steel rad breather type building underlay. 8mm ostik Safe Seal or similar RANZ appraised sealant over bond breaker GC Stratum with all cut sheet edges sealed before fixing. H3.1 treated SG8 timber cavity batten Sealant option GC Stratum and Stratum Duo Soffit Detail NO. ST-20
21 Cavity atten Note: Roofing underlay draining into spouting Min overhang of roofing beyond fascia 50mm Eaves flashing by roofer as required in accordance with NZC Acceptable Solution E2/AS1 Fig 45 Ensure that Stratum projects above top of fascia Solid blocking Ensure that Stratum projects above top of fascia Spouting Internal linings 15mm H3.2 timber fascia of width to suit spouting brackets and falls by others GC Stratum with all cut edges sealed before fixing breather type wall underlay GC Stratum and Stratum Duo Eaves With No Soffit Detail NO. ST-21
22 Cavity atten Note: 35mm Min upstand to head flashing 35 Air seal over PEF rod H3.1 timber packer 7.5mm Min. Jamb sealant to extend to top of continuous meter box angle GC Stratum with all cut edges sealed before fixing 20mm vertical timber cavity batten. H3.1 treated SG8 timber Wall underlay dressed into opening with flexible flashing tape to corners Timber framing Flashing tape lapped over head flashing GC Continuous vent strip 15mm Min overhang 5mm Min gap 10mm Min flashing cover Meter box by others Colorsteel head flashing with 15 fall & 20mm stop ends Metal angle. Angle to be continuous around meter box. Screw fix and seal. Note. Where Durabarrier is used flashing tape must be applied to the entire opening GC Stratum and Stratum Duo Meter ox Head Detail NO. ST-22
23 Cavity atten Note: Air seal over PEF rod Timber framing Wall underlay dressed into opening with flexible flashing tape to corners 20mm vertical timber cavity batten. H3.1 treated SG8 timber GC Stratum with all cut edges sealed before fixing Optional 40 x 18mm H3.2 precut timber scriber 20 mm 7.5mm Min. 10 min cover H3.1 timber packer Metal angle. Angle to be continuous around meter box. Screw fix and seal. Line of head flashing over Continuous sealant over bond breaker to extend up to top of angle Meter box by others Head flashing to extend 20mm past meter box angle Note. Where Durabarrier is used flashing tape must be applied to the entire opening GC Stratum and Stratum Duo Meter ox Jamb Detail NO. ST-23
24 Cavity atten Note: Air seal over PEF rod H3.1 Timber packer Meter box by others 7.5mm Min. 10 Min. Aluminium angle. Angle to be continuous around meter box. Screw fix and seal. 10mm Min cover of weatherboards to metal angle fixing Continuous silicone sealant over bond breaker 15mm Continue wall underlay around framing Wall underlay and flexible flashing tape GC Stratum with all cut edges sealed before fixing 20mm vertical timber cavity batten. H3.1 treated SG8 timber Note. Where Durabarrier is used flashing tape must be applied to the entire opening breather type building underlay. GC Stratum and Stratum Duo Meter ox Sill Detail NO. ST-24
25 breather type building underlay. Timber framing Flexible flashing tape dressed up and securely adhered to building underlay at rear of cavity 5 min slope Cavity battens positioned to form clear channel between sloped timber capping and batten Sloped packer to extend across cavity at wall junction Flexible flashing tape dressed min. 50mm down face of battens Flashing tape continuous around corner over building underlay (100mm wide each side) FLEXILE FLASHING INSTALLATION H3.1 treated timber cavity batten set 40mm back for corner 50mm min 50mm min 5 min slope Cavity atten Note: 100mm min SADDLE FLASHING Two lines of sealant to capping and flashing Timber framing Durabarrier or approved breather type building underlay. GC Stratum with all cut edges sealed with GC edge sealer or similar before fixing. Lower edge of cladding H3.1 treated SG8 timber cavity batten Rivet through sealant Saddle flashing behind cladding Corner flashing behind saddle flashing and cladding Two lines of sealant to capping and flashing attens behind saddle flashing and corner flashing Capping flashing Flashing tape to separate metal capping and treated timber packer Timber framing GC Stratum with all cut edges sealed with GC edge sealer or similar before fixing. Durabarrier or approved breather type building underlay. GC Stratum and Stratum Duo Enclosed alustrade-wall Junction 3D Detail NO. ST-25
26 Cavity atten Note: Metal flashing with 5 slope on flashing tape or roof underlay to separate metal capping and treated timber packer. Fix through sides only. Z Z Sloping H3.1 treated timber packer to form min 5 slope. 40 x 2.8mm Nail Metal flashing to have birds beak fold if used as inside face for enclosed desks GC Stratum with all cut edges sealed before fixing. breather type building underlay. H3.1 timber framing. 15mm Flashing tape continuous around top of framing over building underlay GC Stratum with all cut edges sealed before fixing. H3.1 treated SG8 timber cavity batten Note: Z = Refer to NZC E2 / AS1 Table 7 for flashing cover requirements GC Stratum and Stratum Duo Enclosed alustrade/parapet Detail NO. ST-26
27 Cavity atten Note: Line of sloping H3.1 treated packer above shown dashed breather type building underlay GC Stratum with all cut edges sealed before fixing 90x90 0.7mm galv flashing Stratum adhered to flashing with cont. 6mm bead of ostik Seal 'N' Flex FC 30x1.6mm C Series Stainless Steel rad H3.1 treated SG8 timber cavity batten position 40mm from corner 150mm min to face of window or door jamb stud 40mm min 40 mm min 40 mm min Flashing tape continuous around corner over building underlay (100mm wide each side) 65x2.8mm Roundrive ring shank galv nail. Timber framing as indicated GC Stratum and Stratum Duo Enclosed alustrade-wall Junction Detail NO. ST-27
28 Cavity atten Note: breather type building underlay. H3.1 treated SG8 timber cavity batten. GC Stratum with all cut edges sealed with GC edge sealer or similar before fixing. Flexible flashing tape lapped over apron flashing upstand Parallel apron flashing to extend over two crests fall Parallel apron flashing formed with stop end to deflect water into gutter Transition tray flashing to underside of roofing in accordance with NZC E2/AS1 External gutter to be kept 10mm clear of cladding Fascia with transition tray flashing GC Stratum and Stratum Duo Gutter to Wall Junction NO. ST-28
29 Cavity atten Note: breather type building underlay or flexible flashing tape lapped over apron flashing GC Stratum with all cut edges sealed before fixing GC Continuous vent strip Support nog 110mm 75mm 35mm min x 15mm 110mm upstand flashing with 10mm hem & cover of two crests Timber framing Underlay carried up face of framing behind upstand flashing 5mm gap max for notched downturn Note: x = Refer to NZC E2 / AS1 Table for flashing cover requirements GC Stratum and Stratum Duo Parallel Apron Flashing Detail NO. ST-29
30 Cavity atten Note: breather type building underlay or flexible flashing tape lapped over apron flashing GC Stratum with all cut edges sealed before fixing Continuous vent strip min 15 Apron flashing 125mm upstand flashing with hem. Support nog x Selected roofing material with upturn Timber Framing. Underlay carried up face of framing behind upstand flashing. Roof framing. Note: x = Refer to NZC E2 / AS1 Table for flashing cover requirements GC Stratum and Stratum Duo Transverse Apron Flashing Detail NO. ST-30
31 Cavity atten Note: Wall underlay 20mm vertical timber cavity batten. H3.1 treated SG8 timber Air seal all round Where possible, provide outwards fall to pipework for water run-off Air seal all round Flange to protect sealant from exposure to sunlight Flexible flashing tape adhering around pipe and onto building underlay (100mm lap to underlay and 25mm to pipe) Sealant with backing rod Pipe with 5 slope Solid backing around pipe penetration 20mm vertical timber cavity batten. H3.1 treated timber GC Stratum with all cut edges sealed before fixing Wall underlay GC Stratum and Stratum Duo Pipe Penetration Detail NO. ST-31
C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit
Horizontal battens between verticals at soffit 2 C.04 600 600 600 600 Cavity batten at 600 mm centres 1 C.03 Batten fixing points 1 C.04 1 C.07 1 C.12 1 C.13 1 C.14 Meter Box Window 1 C.08 1 C.09 800 800
More informationBBS Rusticated & Splaycut Cavity System
BBS Rusticated & Splaycut Cavity System 2018 www.bbstimbers.co.nz www.cedarcorp.co.nz BBS Rusticated & Splaycut Weatherboard Cavity Wrap System Installation Specifications 1.0 General Information Introduction
More informationSystem for 2+ Level Buildings
Issued Sept 205 Contact Info@symonite.co.nz System for 2+ Level Buildings Typical Details Issued: September 205 TYPICAL DETAILS CONTENTS.0 TYPICAL VERTICAL JOINTS 2.0 EXT. CORNER / TYPICAL HORIZONTAL JOINT
More informationUlltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4.
Ulltraclad Aluminium Cladding Contents 1.0 General Information 2 2.0 Design Information 4 3.0 Installation Information 7 4.0 Maintenance 10 5.0 Health & Safety 10 1 1.0 General Information 1.1 Introduction
More informationTARANAKIPINE WEATHERBOARD SYSTEM Installation information and technical drawings TIMBER WEATHERBOARDS NATURALLY BETTER FOR MORE THAN A CENTURY www.taranakipine.co.nz 1 CONTENTS May 2015 For the latest
More informationTYPICAL BARGE DETAIL - CROSS SECTION
SELECTED OWENS CORNING ASPHALT SHINGLES APPLY A BEAD OF BITUMASTIC ADHESIVE/SEALANT METAL BARGE DRIP EDGE FLASHING No15 RAG FELT ROOF UNDERLAY PLYWOOD ROOF FRAME BARGE BOARD SOFFIT LINING (IF APPLICABLE)
More informationThe WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 1 October 2012 Ver. 1.2 Window Association of New Zealand Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening
More informationSTEEL FRAMING WEATHERBOARD SYSTEM
T A R A NAK IPINE STEEL FRAMING WEATHERBOARD SYSTEM Installation information and technical drawings TIMBER WEATHERBOARDS NATURALLY BETTER FOR MORE THAN A CENTURY www.taranakipine.co.nz T A R ANAKIPINE
More informationPipe penetration refer CT15. Viking CertainTeed Shingles General Roof details
Vented ridge refer CT02 Substrate Viking SuperStrand or F11 Roofing ply Pipe penetration refer CT15 Valley details refer CT07 and CT08 refer CT17 and CT18 for requirements Drip-edge refer CT01 Barge detail
More information4256HM JAMES HARDIE MONOLITHIC CLADDING
4256HM JAMES HARDIE MONOLITHIC CLADDING 1. GENERAL This section relates to the supply and fixing of fibre cement flush finish cladding: - James Hardie Monotek Sheet for textured coating systems - James
More informationSTOPOREN FACADE SYSTEM TIMBER WINDOW JOINERY - HEAD DETAIL
INTERNAL LINING TIMBER LINTEL AS PER NZS 3604 FLEXIBLE FLASHING TAPE INSTALLED OVER AT AIRSEAL ON CORNERS PEF ROD GAP 7.5-8mm APPROX 35 RENDER 20mm DRAINED & VENTED CAVITY - BATTENS AT 300-600mm MAX.CTRS.
More informationHow-To-build guide Garden shed
How-To-build guide Garden shed What you can build using this guide This guide will show you how to build a re-locatable garden shed. Before you begin building Contact your local territorial authority to
More informationA-lign Technical Manual
A-lign Technical Manual Bevelback Weatherboard Nail-free Boardface System Solution High Moisture Protection From Renewable Wood Fast Install & Less Waste NZBC Compliant Primed & Undercoated BRANZ Appraised
More informationDurasheetTM Fibre Cement
DurasheetTM Fibre Cement fibre cement sheets Durasheet TM - tough and durable History & Mission BGC Fibre Cement is a proud Australian owned manufacturer of fibre cement products. BGC has state-of-the-art
More informationSPECIFICATION FOR. BRANZ Appraisal Certificate # 621 (2008)
SPECIFICATION FOR TEKTON WEATHERIZATION SYSTEM BRANZ Appraisal Certificate # 621 (2008) MW TWS 10/07/2012 Page 1 SYSTEM DESCRIPTION The Tekton Weatherization System consists of TEKTON Wall Underlay, Tekton
More informationALPINE TRAY. To get the best from this product please follow these recommendations.
F I X I N G D E TA I L S ALPINE TRAY The standing seam roofing profile is designed to withstand some of New Zealand s harshest weather in our toughest environments. To get the best from this product please
More informationTimber Cavity Batten Technical Specifiction
Timber Cavity Batten Technical Specifiction OCTOBER 2016 I NEW ZEALAND Contents 1 APPLICATION AND SCOPE 3 1.1 Application 3 1.2 Scope 3 1.3 Details 3 1.4 Specific Design 3 2 DESIGN 3 2.1 Compliance 3 2.2
More informationNULINE PLUS WEATHERBOARD CAVITY SYSTEM. Product. Scope. Appraisal No. 641 [2015]
NULINE PLUS WEATHERBOARD This Appraisal replaces BRANZ Appraisal No. 641 (2009). BRANZ Appraisals Technical Assessments of products for building and construction. Appraisal Holder: BGC Fibre Cement Australia
More informationInstallation instructions: Elements Vulcan+ Newport Hector Cladding
Technical Data Wood Species Thermally Modified Softwood (Pinus Radiata) Images Profile Newport Hector - Light Band Sawn face - Secret fix 5.4 6.0 8.5 3.0 25.0 3.0 111.0 3.0 12.0 R 3.0 7.0 7.0 123.0 15.0
More informationSTOLITE CONSTRUCTION SYSTEM EXT.CORNER - MANUF.STONE/STOLITE
RENDER TIMBER FRAMING WALL UNDERLAY CONTINUOUS AROUND CORNERS, POLYPROPYLENE TAPE APPLIED TO PROTECT WALL UNDERLAY 75mm MIN.WIDE CLIP ON MS SEALANT ON PEF ROD SEALANT TO JUNCTION PROPRIETARY MANUF.STONE
More informationTEKTON WEATHERIZATION SYSTEM SPECIFICATION
MWNZ Tekton Weatherization System AUG 2017 TEKTON WEATHERIZATION SYSTEM SPECIFICATION SYSTEM DESCRIPTION The Tekton Weatherization System consists of TEKTON Wall Underlay, Tekton SEAM TAPE, TRADE-SEAL
More informationShingle Installation Guide
Installation Guide Roof Framing Information Installation Installation Accessory Installation Estimating Data General Information Roof Framing Information It is the responsibility or roofers, building contractors
More informationROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION
ROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION ROOF FRAMING INFORMATION It is the responsibility or roofers, building
More informationWO OD LOCK W E AT H ERBOARDS & FASCIA Installa tion info r m at ion and t echnic al draw ings
TARANAKIPINE WO OD LOCK W E AT H ERBOARDS & FASCIA Installa tion info r m at ion and t echnic al draw ings TIMBER WEATHERBOARDS NATURALLY BETTER FOR MORE THAN A CENTURY www.taranakipine.co.nz TA R A N
More informationADGV_001_FASTPOS. Date Jan 2013 Detail. Profile. Fastener Positioning Scale 1:20 Detail No. ADGV_ mm from top edge. 600mm MAX CTRS TIMBER STUDS
ADGV_001_FASTPOS Panel Timber Frame 12mm from top edge 600mm MAX CTRS TIMBER STUDS 200 mm MAX CTRS 50mm from corner Fastener Positioning Scale 1:20 No. ADGV_001 ADGV_003_SHTEDGEPOS Centre line of Timber
More informationRECOMMENDED INSTALLATION PROCEDURE LEVEL 3
Step 1. Install Sill Flashing Product: 9" or 12" RainBuster #440 SubZero Flashing Tape 1.A Flashing Length = (Rough Opening Width) + 12" 1.B Install sill flashing flush with the sill of the rough opening.
More informationSuperFOIL Insulation. Solutions Guide. Pitched Roof - Under Rafter
SuperFOIL Insulation Solutions Guide Pitched Roof - Under Rafter SF19+ Pitched Roof Under Rafter Solutions CONSTRUCTION THICKNESS R -VALUE EXTERNAL SURFACE - 0.040 TILES / SLATES 10mm - BATTEN CAVITY 25mm
More informationINSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS
www.capecodsiding.com INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS IMPORTANT READ THE FOLLOWING INSTRUCTIONS CAREFULLY BEFORE INSTALLING YOUR WOOD SIDING. FAILURE TO STRICTLY FOLLOW THESE INSTALLATION,
More informationREDLAND DRY VALLEY. Installation Instructions for Redland Dry Valley. Version: 6. Date: May Redland Technical Solutions
REDLAND DRY VALLEY Installation Instructions for Redland Dry Valley Version: 6 Date: May 2013 Author: Department: Redland Technical Solutions Redland Technical Solutions 1 Introduction 1.1 TECHNICAL DATA
More informationtechnical bulletin Roofline Installation Details No.7 Fascia Installation Details Typical Eaves Details K16 Fascia & 9mm Vented Soffit
Roofline Installation Details This is intended to provide you with a brief overview of the popular products in Kestrel s Roofline range, where they can be used and the main criteria for installation. Typical
More informationThe WANZ Guide to Window Installation. as described in E2/AS1 Amendment 7
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 7 1 November 2017 Version 1.4 0800 397 263 technical@altus.co.nz The WANZ Guide to Window Installation as described in E2/AS1 Amendment
More informationA REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS
WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME
More informationNULINE PLUS WEATHERBOARD DIRECT FIXED CLADDING SYSTEM. Product. Scope. Appraisal No. 640 [2015]
NULINE PLUS WEATHERBOARD DIRECT FIXED CLADDING This Appraisal replaces BRANZ Appraisal No. 640 (2009). BRANZ Appraisals Technical Assessments of products for building and construction. Appraisal Holder:
More information900 SERIES WALL PANELS
CI-DS-01-900 CI-PP-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-PJ-03-900 CI-BS-01-900 CI-BS-02-900 CI-BS-03-900 CI-BS-04-900 CI-BS-05-900 CI-OC-01-900 CI-OC-02-900 CI-IC-01-900 CI-FO-01-900 CI-FO-02-900 CI-FO-03-900
More informationBest Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.
Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications. EXTERIOR INSULATION & FINISH SYSTEM CONSTRUCTION Data Published Courtesy
More informationtechnical bulletin Roofline Installation Details No.7 Fascia Installation Details Typical Eaves Details K16 Fascia & 9mm Vented Soffit
Roofline Installation Details This is intended to provide you with a brief overview of the popular products in Kestrel s Roofline range, where they can be used and the main criteria for installation. Typical
More informationCFDTT-01. Control Joint Study (General)
Trim Method Classic Method Notes: Control joints are required and should be located by the designer at the following locations on the construction documents: 144 sf (13.4 sm) is the maximum overall area
More informationShapes Siding. Perfection Shingles. Chalk Line
Snap a Chalk Line Shapes Siding Perfection Shingles Chalk Line To establish a straight reference line to guide the positioning of the starter strip and the first course of siding, snap a chalk line. starter
More informationThermoSpan EPS. Metalcraft COMMERCIAL ROOFING CREPS. Insulated Panel Systems DETAIL LIST
ThermoSpan EPS DETAIL LIST 00 / 15 COVER SHEET 01 / 15 RIDGE DETAIL 02 / 15 HEAD FLASHING DETAIL 03 / 15 EAVES GUTTER DETAIL 04 / 15 INSULATED GUTTER 05 / 15 INSULATED BOX GUTTER 06 / 15 BARGE CAPPING
More informationAQUAGARD EPDM FLAT ROOFING SYSTEMS INSTALLATION GUIDE THE MECHANICALLY FIXED SYSTEM
AQUAGARD EPDM FLAT ROOFING SYSTEMS INSTALLATION GUIDE THE MECHANICALLY FIXED SYSTEM The following guide covers the technique for the Mechanically Fixed System. This system is best employed when an overlay
More informationA-lign Technical Manual
A-lign Technical Manual Vertical Shiplap Weatherboard High Moisture Protection Fast Install & Less Waste Primed & Undercoated From Renewable Wood System Solution From Renewable Wood BRANZ Appraised NZBC
More informationE2 REDWAY FLASHINGS. Product. Scope. Appraisal No. 977 [2017] Appraisal No. 977 (2017) BRANZ Appraisals
E2 REDWAY FLASHINGS BRANZ Appraisals Technical Assessments of products for building and construction. Redway Developments Limited 162 Kendal Ave Burnside Christchurch Tel: 03 358 5775 Email: info@e2flashings.co.nz
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised July 27, 2012 the North Dakota with pocket doors 12' x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This
More informationBevel back. Technical & installation manual. Component details & drawings installation guide maintenance & care warranty
Technical & installation manual Bevel back June 2017 edition www.niagara.nz Component details & drawings installation guide maintenance & care warranty Envira bevel back weatherboards and components are
More informationDW HORIZONTAL INSTALLATION
AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S
More informationInstallation guide for 20/20
Introduction The following installation instructions are recommended minimum requirements for the 20/20. The designer and fixer should ensure that tiles are installed in accordance with BS 5534; The British
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised September 13, 2017 the North Dakota with pocket doors 12' x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 This manual
More informationThe Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA
TRS 9 35MM 78MM 150MM 78MM THICKNESS END SPAN INTERNAL SPAN MINIMUM PITCH 0.55MM 2.30M 3.20M 3 DESCRIPTION TRS 9 profile is designed for commercial and industrial roofing. The profile is suitable for low
More informationSpeedDeck. Fixing and Handling Guide
SpeedDeck Section 1 Delivery/Storing On Site/Handling l SpeedDeck is factory or on-site manufactured. l Straight SpeedDeck bundles are a maximum 1 tonne, sheets nestled and banded with polypropylene or
More informationNEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING
NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS Reference Guide 0.1 GENERAL 0.1 Reference Guide 0.2 Index 0.3 Disclaimer & Limitations 0.4 General Notes
More informationTHIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE
BRANZ Appraised Appraisal No. 547 [2007] NURALITE Nuralite Waterproofing Ltd. 53A Victoria Street, Onehunga, Auckland 1061, Zealand TEL: (64) (9) 579-2046 FAX: (64) (9) 579-5136 email: info@nuralite.co.nz
More informationSHADOWCLAD SPECIFICATION & INSTALLATION GUIDE
SHADOWCLAD SPECIFICATION & INSTALLATION GUIDE FOR CAVITY CONSTRUCTION MAY 2018 Information contained within is specific to Shadowclad structural plywood products and must not be used with any other plywood
More informationDUTCH GABLE FREESTANDING CARPORT
DUTCH GABLE FREESTANDING CARPORT STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. Your complete guide to building a FREESTANDING Outback DUTCH GABLE CARPORT BEFORE YOU START Carefully read these instructions. If
More informationGeneral Installation Guidelines
g e n e r a l i n s t a l l a t i o n g u i d e l i n e s General Installation Guidelines Although Nutec Building Planks do not contain asbestos fibres, it is nevertheless recommended that when working
More information3M Air and Vapour Barrier 3015 Technical guide
3M Air and Vapour Barrier 3015 Technical guide Product overview Typical physical properties For installation ease and flexibility, 3M Air and Vapour Barrier 3015 High performance 3M acrylic adhesive grabs
More informationXL JOINERY LTD LA PORTE VISTA MODULAR 3 ASSEMBLY INSTRUCTIONS
XL JOINERY LTD LA PORTE VISTA MODULAR 3 2090mm High x 4687mm Wide ASSEMBLY INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS FULLY PRIOR TO STARTING INSTALLATION. IT IS STRONGLY RECOMMENDED THAT A COMPETENT
More informationGuardian warm roof conversion system. Installation Guide
Guardian warm roof conversion system Installation Guide 2 www.guardianroof.co.uk Conservatory walls consist largely of glazed elements including windows and doors that may include structural mullions or
More information9.0 PS Pacbld Sidings
The application: 9.0 PS Pacbld Sidings Revision: June 2017 9.0 PS Pacbld Sidings Full Manual Revision: Jun 2017 Contents 1. Product Information 2. Quality Assurance Check Sheet 3. Maintenance 4. Details
More informationKS42 MF SERIES - HORIZONTAL INSTALLATION
CI-DS-01-KSMF H CI-PJ-01-KSMF H CI-PJ-02-KSMF H CI-PJ-03-KSMF H CI-PJ-04-KSMF H CI-PJ-05-KSMF H CI-PJ-06-KSMF H CI-PJ-07-KSMF H CI-PJ-08-KSMF H CI-PJ-09-KSMF H CI-PJ-10-KSMF H CI-PJ-11-KSMF H CI-PJ-12-KSMF
More informationKS SERIES - VERTICAL INSTALLATION
CS-DS-01-KSV CS DISCLAIMER CS-PJ-01-KSV KS42SL EXPANDED PANEL JOINT CS-PJ-02-KSV KS42SL ENGAGED PANEL JOINT CS-PJ-03-KSV KS45SL EXPANDED PANEL JOINT CS-PJ-04-KSV KS45 FLAT ENGAGED PANEL JOINT CS-PJ-05-KSV
More informationJAMES HARDIE RIGID AIR BARRIERS
Product 1.1 James Hardie Rigid Air Barriers are a range of rigid wall underlay materials including RAB Board and HomeRAB Pre-Cladding. They are sealed fibre cement sheets designed for use as rigid wall
More informationTRADE SILL FLASHING TAPE. Product. Scope. Appraisal No. 712 [2012] Appraisal No. 712 (2012) Amended 19 July BRANZ Appraisals
TRADE SILL FLASHING TAPE Amended 19 July 2017 BRANZ Appraisals Technical Assessments of products for building and construction. Marshall Innovations Limited PO Box 9411 Greerton Tauranga Tel: 07 543 0948
More informationeco-shake INSTALLATION INSTRUCTION
1 eco-shake INSTALLATION INSTRUCTION NOTE: Shuffling the eco-shakes during installation may be necessary to obtain a uniform color throughout the roof. Due to the natural wood content in the ecoshakes,
More informationSTOPOREN FACADE SYSTEM DRAWING REGISTER
Drawing Description STO DRAWING REGISTER Drawing No. Drawing Register PP 001-006 Introduction Series 000 StoPoren Facade System StoArmat Render System PP 007 StoPoren Facade System StoPoren Render System
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised September 13, 2017 the North Dakota with pocket doors Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 Building Size 12'x12'
More informationContents. Stage 1. Preparation of the aperture 9. Interior finishing 25
Installation Manual Pitchglaze Roof Window Contents Contents and introduction 2 Delivery 3 Pre Installation 4 Installation 8 Stage 1. Preparation of the aperture 9 Stage 2. Fitting the Pitchglaze 11 Stage
More informationEnsure there is reasonable access for materials and working space, ensure the shed site is level and consider the disposal of run-off water.
INSTALLATION GUIDE TM Flat Roof Homesheds THE POTTER BEFORE YOU START It is important to check your Local Government Authority requirements before the installation of your new Stratco Potter Flat Roof
More informationMULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET
KPH-DS-01-MTLV KPH-PP-01-MTLV KPH-PP-02-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-FS-01-MTLV KPH-FS-02-MTLV KPH-FS-03-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV
More informationInstallation Guide - Evolution Series Wood Siding
Installation Guide - Evolution Series Wood Siding The following instructions pertain to the installation of Fraser Wood Siding Evolution Series on a typical wood frame construction allowing for nail penetration
More informationPROTECTO SILL WINDOW SEALING SYSTEM. Product. Scope. Appraisal No. 444 [2017]
PROTECTO SILL WINDOW SEALING SYSTEM This Appraisal replaces BRANZ Appraisal No. 444 (2011) BRANZ Appraisals Technical Assessments of products for building and construction. Marshall Innovations Limited
More informationBUILDING THE BASIC SHED. Step A: Build the Foundation & Floor Frame
BUILDING THE BASIC SHED Step A: Build the Foundation & Floor Frame 1. Excavate the building site and add a 4" layer of compactible gravel. If desired, add an extension to the base for the optional wood
More informationCERACLAD.
CERACLAD 4. Horizontal Application (Wood Structure) Instructions and Details Siding Panel Installation Accessories Installation Overview Starter Bar Installation Install s Installation
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised November 19, 2015 the Arlington-R Building Size 12' x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This
More informationDW VERTICAL INSTALLATION
AR-PJ-01-DW5V AR-PJ-02-DW5V AR-PJ-03-DW5V AR-PJ-04-DW5V AR-BS-01-DW5V AR-BS-02-DW5V AR-OC-01-DW5V AR-OC-02-DW5V AR-OC-03-DW5V AR-IC-01-DW5V AR-IC-02-DW5V AR-IC-03-DW5V AR-FO-01-DW5V AR-FO-02-DW5V AR-FO-03-DW5V
More informationAcceptable Standards of Domestic Construction
Truss or Rafter Roof Batten Triple grip fastener (for roof trusses) Foil lined Insulation blanket Top plate Sprocket Brick tie Top plate strapping at 1200mm max. cts. Note: Holding down straps should be
More informationtechnical datasheet Eaves Protector Stainless Steel Polytop Fixings 2 x 600mm Centres Eaves Protector
Fascia Installation Details technical datasheet Typical Eaves Details ABL Fascia & 9mm Vented Soffit Eaves Protector This section of the guide is intended to provide you with a brief overview of the popular
More informationWith Illustrations, Blueprints & Step By Step Details Brought To You By ShedPlansz.Com Click Here To Get More Shed Plans
12 X 8 Shed Plans With Illustrations, Blueprints & Step By Step Details Brought To You By ShedPlansz.Com Click Here To Get More Shed Plans Blueprints And Diagrams Instructions For Building The Shed
More information400 SERIES VERTICAL INSTALLATION
CI-DS-01-400V CI-PJ-01-400V CI-PJ-02-400V CI-PJ-03-400V CI-BS-01-400V CI-BS-02-400V CI-BS-03-400V CI-BS-04-400V CI-BS-05-400V CI-OC-01-400V CI-OC-02-400V CI-IC-01-400V CI-IC-02-400V CI-FO-01-400V CI-FO-02-400V
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised September 12, 2017 the Arlington Building Size 12' x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 This manual is copyrighted.
More information50948-RHN Putney. 06 January This document includes: Aluminium strip/ sheet coverings/ flashings 1. Code Section Revision Dated
50948-RHN Putney 06 January 2018 This document includes: Code Section Revision Dated H72 Aluminium strip/ sheet coverings/ flashings 1 Table of Contents Title H72 Aluminium strip/ sheet coverings/ flashings
More informationIntegrate the Window and WRB (1/2)
Window and WRB Installation - Window/WRB. Cut the house wrap flush along all sides of the rough opening.. Slope the sill and flash with flashing tape. Push the tape tight into the corners, being careful
More informationTechnical Specification MARCH 2017 I NEW ZEALAND
Technical Specification MARCH 2017 I NEW ZEALAND Contents 1 APPLICATION AND SCOPE 3 1.1 Application 3 1.2 Scope 3 1.3 Details 3 1.4 Specific Design 3 2 DESIGN 3 2.1 Compliance 3 2.2 Responsibility 3 2.3
More informationMaterials. Description Quantity/Size Material Foundation Drainage material. 1.4 cu. yd. Compactible gravel
This 8 12-ft. shed features a simple gable roof, double doors, and side and rear windows for natural lighting. With full-height walls and doors, there's ample room for storing large items or creating a
More informationHow To Install Windows: Nail-Fin Application
How To Install Windows: Nail-Fin Application Required Tools & Materials: Materials: 1 3/4" galvanized roofing nails. Nails must penetrate at least 1" into framing For mulled and/or DP50 or above units:
More informationVENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4
GABLE FLASHING FASTENER @ 24" C/C MAX. ROOF PURLIN BUTYL SEALANT TAPE FLASH AB-1, AB-2, AB-3, OR AB-4 FASTENER @ EVERY MAJOR RIB OR 12" C/C MAX. F-J TRIM FABRAL ALUMINUM SOFFIT FASTENER 24" C/C MAX. BUTYL
More informationCURVED ROOF ASSEMBLY INSTRUCTIONS ATTACHED VERANDAH. Your supplementary guide to building an ATTACHED CURVED ROOF VERANDAH or PATIO BEFORE YOU START
ROOF ATTACHED VERANDAH ASSEMBLY INSTRUCTIONS Your supplementary guide to building an ATTACHED ROOF VERANDAH or PATIO This set of instructions should be used in conjunction with the Stratco instruction
More informationInstallation Guide. ExoTec TM Facade Panel And Fixing System COMMERCIAL
Installation Guide ExoTec TM Facade Panel And Fixing System COMMERCIAL Certificate CM40221 Australia April 2018 Make sure your information is up to date. When specifying or installing James Hardie products,
More informationSAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the North Dakota with pocket doors. Building Size 12'x12' or 12'x16' Revised August 30, 2011
Best Barns USA Assembly Book Revised August 30, 2011 SAMPLE INSTRUCTIONS the North Dakota with pocket doors Building Size 12'x12' or 12'x16' Manufactured by Reynolds Building Systems, Inc. 205 Arlington
More informationInstaller s Handbook. Pocket Guide to Roofline & Cladding Installation BBA BRITISH BUILDING PRODUCTS
Uniclass L5:P7113 CI/SfB (4-) Hn7 Installer s Handbook Pocket Guide to Roofline & Cladding Installation BBA BRITISH BOARD OF AGRÉMENT CERTIFICATE NO.91/2620 CERTIFICATE NO.91/2622 BS 7619 Licence No. KM33730
More informationA Shell construction
A Shell construction A 4/2012 Content 1 BASE AND WALL ANCHORING 1.1 Base with mortar bed 1.2 Base with sill plate 1.3 Base with raised sill plate 1.4 Concrete base (mortar bed) 1.5 Concrete base (sill
More informationmanthorpe Roll-Out Dry Fix Ridge System building products Fixing Instructions MBP 8265e
manthorpe building products Roll-Out Dry Fix Ridge System Fixing Instructions MBP 8265e Ridge Details Fig A. Assembly View of Dry Ridge Detail s/s screw clamping plate rubber washer foam spacer ridge tile
More informationInstallation Instructions
Installation Instructions Alcove Enclosure Before Installation please check that your shower enclosure system is undamaged Please read these instructions carefully March 2015 TOOLS REQUIRED Electric or
More informationRoll-Fix Kit The complete dry hip kit RFIG
H I P Roll-Fix Kit The complete dry hip kit RFIG.045-0906-1 Roll-Fix is a quick and simple dry-fix roofing kit for hips. l Quick and easy to install no special tools required l Universal application fits
More informationSANERI 3 º. Self-adhesive SBS-elastomer bitumen cap sheet
SANERI 3 º Self-adhesive SBS-elastomer bitumen cap sheet 0809 www.katepal.fi 06 EN 13707 Producer: KATEPAL OY P. O. Box 33 FI-37501 LEMPÄÄLÄ FINLAND Tel. +358 (0)3 375 9111 Fax +358 (0)3 375 0974 E-mail:
More informationCOMPOSITE SIDING INSTALLATION GUIDE
CENTURY HOME LIVING COMPOSITE SIDING INSTALLATION GUIDE Read all instructions prior to installing any siding product. Failure to install and finish this product in accordance with all local building codes,
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised March 6, 2017 the Arlington Building Size 12' x 24' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive - Greenville, PA 16125 This manual is copyrighted.
More informationFinesse Profiles. Nailstrip
Installation Details Profile and Lap Detail 265/465 38mm NAILSTRIP *other widths available CD GRADE PLYWOOD 19mm STRUCTURE SILICONE * MIN 20mm VENTILATION GAP * WHEN ROOF PITCH IS UNDER 7.5 OR TOTAL COMBINED
More informationHOW TO BUILD A 12X8 SHED
HOW TO BUILD A 12X8 SHED With Illustrations, Drawings & Step By Step Details Note: This is a sample plan from RyanShedPlans. All other plans in our collection goes indepth with more details, more instructions,
More informationShow them you're an InstallationMaster, and watch your business grow. InstallationMasters Training Manual Addendum Level RLC-1
Show them you're an InstallationMaster, and watch your business grow. InstallationMasters Training Manual Addendum Level RLC-1 August 2007 This addendum was developed by the InstallationMasters Institute
More informationWith Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e H O W B U I L D S H E D.
With Illustrations, Drawings & Step By Step Details Click Here To Download 12,000 Shed Plans 1 P a g e H O W B U I L D S H E D. C O M Table of Contents OVERVIEW... 3 MATERIALS & CUTTING LISTS... 4 DRAWINGS,
More information