Pipe penetration refer CT15. Viking CertainTeed Shingles General Roof details
|
|
- Angelina Beasley
- 5 years ago
- Views:
Transcription
1 Vented ridge refer CT02 Substrate Viking SuperStrand or F11 Roofing ply Pipe penetration refer CT15 Valley details refer CT07 and CT08 refer CT17 and CT18 for requirements Drip-edge refer CT01 Barge detail refer CT06 Truss or Rafter Nail fixed to Plywood or SuperStrand sarking Refer to Viking CertainTeed specification for fixing details in required wind-zone Step Flashing refer CT09 General Roof details Details A
2 CertainTeed Shingles Viking Underlay Plywood or SuperStrand sarking Substrate to comply with current Viking Roofspec Masterspec specification Substrate Checksheet available from Timber nog required to support bottom edge of substrate not to restrict airflow for ventilation 30mm Air flow for vented intake 10mm Metal drip-edge flashing Airflow gap 10mm above top of Fascia Vented Drip-edge Detail CT01 CT01 A
3 Viking CertainTeed Ridge Vent 25mm depth with ridge Cap installed Airflow Airflow Air gap min. 20mm Plywood or Superstrand sarking Viking CertainTeed Low Profile Ridge Vent 16mm depth Airflow Airflow Air gap 20mm minimum Ridge Vent Detail CT02 CT02 A
4 NOTE: Min. shingle roof pitch is 9 Nail vent to 600mm centres Viking CertainTeed Ridge Vent DDE265 divided in half min. 20mm Refer Table 7 E2/AS1 Nog to support edge of substrate Min. 20mm unrestricted Air flow Truss or Rafter Monopitch Ridge Vent Detail CT03 CT03 A
5 * Alternative ventilation consider venting through the membrane roof area if roof structure allows good unrestricted airflow. Allow additional cavity vent for every 50m2 pitched roof area Viking Waterproof Membrane Discuss with Viking Roofspec best option to secure to metal flashing Optional Dress Shingle if required for asthetics adhered with Viking Pitched Roofing Sealant SES mm centres Metal Flashing with hemmed edge for added strength to hold firm over vent *Viking CertainTeed Ridge Vent DDE265 divided in half Viking Shingle Nails 32 x 3.2mm S/S 10mm round Flathead Air gap 20mm Min. Airflow uninhibited Roof Cavity (min 25mm) Substrate to comply with current Viking Roofspec Masterspec specification Substrate Checksheet available from Mansard Vented edge Detail CT04 CT04 A
6 150mm Nail to 600mm centres Viking Skirt Vent DDE200 Airflow Roof Cavity (min 25mm) 20mm Lower Vented Roof Detail CT05 CT05 A
7 70mm Viking Pitched Roofing Sealant SES013 15mm overhang refer Table 7 E2/AS1 Barge Flashing Barge edge Detail CT06 CT06 A
8 Viking CertainTeed Hip Cap Shingle Viking Shingle Nails 32 x 3.2mm S/S 10mm round Flathead Substrate to comply with current Viking Roofspec Masterspec specification Substrate Checksheet available from NOTE: Valley Detail refer also detail CT08iso Minimum 150mm overlap 450mm 50mm 250mm Viking Underlay applied over first shingle layer. Minimum 50mm overlap over Shingle required. Apply a full width (900mm) of Viking Underlay vertical to Plywood Roofing Substrate Valley Pitched Roofing Sealant no nails within 150mm of Valley center line Hip & Valley Detail CT07 CT07 A
9 Note Lay Shingles on smaller roof area, across valley and onto adjoining roof area at least 300mm Viking Underlay Laps DO NOT nail within 150mm of valley Centreline Embed each shingle in 2 beads of Viking Roofing Sealant SES013 Line Valley by centering (914mm wide) Viking Peel & Stick Underlay CUT (50mm) diagonally off upper corner REMOVE trimmed shingle of trimmed shingle and remove cl Isometric Valley Detail CT08iso CT08iso A
10 150mm Viking Butylclad Waterproofing Membrane Step Flashing 150mm wide 150mm Min. 100mm 150mm Pitched Roofing Sealant SES013 no nails through Step Flashings 150mm Corner lap to be secured with Viking 76mm Lap Tape Step-Flashing under every individual Shingle. with min.100mm overlap between flashings. Flashings to be placed just above shingle sealant line 100mm Apron Flashing No nailing through step flashing use 20mm compressed spots of sealant 10mm Gap for water runoff Upstand with Step Flashing Detail CT09 CT09 A
11 Substrate to comply with current Viking Roofspec Masterspec specification Substrate Checksheet available from 300mm wide Strip Butylclad Step-flashing minimum cover 150mm each on the upstand and shingle Viking Kickout Flashing Spouting Drip Edge Flashing Drip-edge with Diverter Detail CT10 CT10 A
12 Dormer Roof Viking CertainTeed selected Shingle Viking Waterproofing Membrane 150mm Vertical Height Viking Waterproofing membrane detail over barge upstand 150mm Dormer to shingle junction Detail CT11 CT11 A
13 Chased Apron Flashing by builder Diverter Corner lap to be secured with Viking 76mm Lap Tape Step Flashing under Shingles Minimum:100mm cover between flashings 150mm upstand and 150mm on roof deck No nailing through step flashing use 20mm compressed spots of CertainTeed sealant SES013 to secure Chimney and Chase Flashing Detail CT12 CT12 A
14 Chased Apron Flashing by builder Diverter Corner lap to be secured with Viking 76mm Lap Tape Step Flashing under Shingles Minimum:100mm cover between flashings 150mm upstand and 150mm on roof deck No nailing through step flashing use 20mm compressed spots of CertainTeed sealant SES013 to secure Alternative Chimney Diverter CT12b CT12b A
15 Generic skylight with proprietary cover flashings min. 110mm upstand Butylclad or metal Flashing refer CT09 for side flashing Aesthetic Tile adhered with 20mm spots of SES013 CertainTeed Sealant Skylight Detail CT13 CT13 A
16 Solar Panel or similar Solar Panel fixing Bracket with sealed fasteners under Shingles to cover brackets and fasteners Structural support for fixing brackets Solar Panel Fixings CT14 CT14 A
17 Viking Pipe Boot placed over pipe and set in Viking Roof sealant SES013 Step 1 Step 2 Upper and Side Shingles overlap flange and are set in Viking Roof sealant SES013 Plumber to overflash pipe boot Lower Part of Flange overlaps lower Shingles Spot seal with 20mm of pitched roofing sealant at 100mm centres Pipe Penetration Detail CT15 CT15 A
18 Viking CertainTeed Starter Shingle Viking GM torch-on 2 Layer waterproofing System 50mm 200mm upstand vertical height Substrate as per Viking membrane specification Truss or Rafter Membrane roof to Pitched roof CT16 CT16 A
19 * Roof pitch 9-12 use only Viking Peel & Stick underlay. Roof Pitch use either Viking Peel & Stick or double layer of Viking Synthetic Underlay Roof Pitch 18 + single layer of Viking Synthetic Underlay is suitable Viking Peel & Stick waterproofing membrane 400mm minimum Viking Peel & Stick Not to be placed over Shingle sealant line Min. 200mm Truss or Rafter *Min. 9 pitch for shingle roofs Min. 200mm Substrate to comply with current Viking Roofspec Masterspec specification Substrate Checksheet available from Shingle Change in Pitch Detail CT17 CT17 A
20 * Roof pitch 9-12 use only Viking Peel & Stick underlay. Roof Pitch use either Viking Peel & Stick or double layer of Viking Synthetic Underlay Roof Pitch 18 + single layer of Viking Synthetic Underlay is suitable Viking CertainTeed underlay *Min. 9 Pitch Aesthetic Tile adhered with 20mm spots of SES013 CertainTeed Sealant 0.55mm Colour Steel Flashing with Birdsbeak or 1mm Butyl rubber flashing refer Table 7 E2/AS1 for coverage Non-Vented Mansard / Change in Pitch CT18 CT18 A
21 250mm Structural framing Valley Nogging Metal Valley Flashing Substrate to comply with current Viking Roofspec Masterspec specification Substrate Checksheet available from Alternative Open Valley Detail CT19 CT19 A
22 Viking Membrane to provide 150mm of vertical height Min. 150mm upstand Viking Waterproofing Membrane Note: No fixings through membrane below 150mm Min fall in gutter 1:100 to external spouting or specified Viking Proprietary outlet MIN. 100mm Cover over membrane Substrate to comply with current Viking Roofspec Masterspec specification Substrate Checksheet available from Internal Gutter CT20 CT20 A
23 NOTE: This detail is to show a methodology for Saddle-flashings and kick-out diverters at junctions. These Saddle-flashings are not supplied by Viking Roofspec as they are fabricated for specific junctions by others to fit various junctions and cladding needs. Min. 50mm 150mm Cavity Battens and cladding over flashings. Note: NO nails through the flashings Example Saddle-flashing NOTE: 2 Refer Viking Typical details for vented apron details etc. Stage 1 Flexible Flashing tape adhered to wall underlay at rear of cavity minimum 50mm to all surfaces Barge Flashing Step 3 Fabricated Saddle-flashing fitted over flexible flashing tape behind the cavity. Size & depth of diverter to suit specified cladding preventing water ingress entering behind cladding and cavity Barge Board refer table 7 of E2/AS1 for coverage Saddle-flashing Methodology CT21 CT21 A
TYPICAL BARGE DETAIL - CROSS SECTION
SELECTED OWENS CORNING ASPHALT SHINGLES APPLY A BEAD OF BITUMASTIC ADHESIVE/SEALANT METAL BARGE DRIP EDGE FLASHING No15 RAG FELT ROOF UNDERLAY PLYWOOD ROOF FRAME BARGE BOARD SOFFIT LINING (IF APPLICABLE)
More informationROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION
ROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION ROOF FRAMING INFORMATION It is the responsibility or roofers, building
More informationAsphalt Shingle Roofing NZ PO Box , Royal Oak Auckland
Asphalt Shingle Roofing NZ PO Box 24-676, Royal Oak Auckland 1345 09 636 7051 0800261116 www.asphaltshingle.co.nz TECHNICAL & INSTALLATION MANUAL This information is provided by Asphalt Shingle Roofing
More informationC.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit
Horizontal battens between verticals at soffit 2 C.04 600 600 600 600 Cavity batten at 600 mm centres 1 C.03 Batten fixing points 1 C.04 1 C.07 1 C.12 1 C.13 1 C.14 Meter Box Window 1 C.08 1 C.09 800 800
More informationShingle Installation Guide
Installation Guide Roof Framing Information Installation Installation Accessory Installation Estimating Data General Information Roof Framing Information It is the responsibility or roofers, building contractors
More informationFibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.
Plank joint 600mm stud crs 600mm 600mm 600mm Horizontal Structural Timber Cavity atten 50x20mm H3.1 atten fixing points 800mm 800mm 300mm 800mm Max. Nog spacing 50mm All intermediate battens to be 50x20mm
More information1 Roof Substrate (Deck) OWENS CORNING BERKSHIRE SHINGLES INSTALLATION INSTRUCTIONS
General This Installation Instruction document for Owens Corning Berkshire roofing shingles is to be read in conjunction with the Installation information printed on each packet of shingles along with
More informationREDLAND DRY VALLEY. Installation Instructions for Redland Dry Valley. Version: 6. Date: May Redland Technical Solutions
REDLAND DRY VALLEY Installation Instructions for Redland Dry Valley Version: 6 Date: May 2013 Author: Department: Redland Technical Solutions Redland Technical Solutions 1 Introduction 1.1 TECHNICAL DATA
More informationOWENS CORNING LAMINATE SHINGLES INSTALLATION INSTRUCTIONS
General This Installation Instruction document for Owens Corning asphalt roofing shingles is to be read in conjunction with the Installation information printed on each packet of shingles along with the
More informationVIKING CERTAINTEED ASPHALT ROOFING SHINGLES. Product. Scope. Building Regulations. Appraisal No. 276 [2012]
VIKING CERTAINTEED ASPHALT ROOFING SHINGLES Amended 11 December 2017 BRANZ Appraisals Technical Assessments of products for building and construction. Viking Roofspec A division of Viking Group Ltd P O
More informationFinesse Profiles. Nailstrip
Installation Details Profile and Lap Detail 265/465 38mm NAILSTRIP *other widths available CD GRADE PLYWOOD 19mm STRUCTURE SILICONE * MIN 20mm VENTILATION GAP * WHEN ROOF PITCH IS UNDER 7.5 OR TOTAL COMBINED
More informationF-WAVE REVIA SYNTHETIC ROOFING SHINGLES
F-WAVE REVIA SYNTHETIC ROOFING SHINGLES Installation Manual for Steep-Slope Residential Installations For support with all other Steep-Slope Installations, please call F-Wave Technical Support at 888-GO-FWAVE.
More informationInstallation guide for 20/20
Introduction The following installation instructions are recommended minimum requirements for the 20/20. The designer and fixer should ensure that tiles are installed in accordance with BS 5534; The British
More informationSmartVent Eave Edge Installation Instructions
SmartVent Eave Edge Installation Instructions STEP 1: Cut a slit 1 wide (or a series of 1 ¾ holes at 3 on center) into the roof decking 6 to 7 up from the drip edge. SmartVent is rated 9NFA. Ensure drip
More informationEkoroof LiteTile Dimensions
Ekoroof LiteTile Dimensions 7 3 3.5 Height 40 Width 20 Length Weight per Panel: 3 kg / 6.61 lbs 2 2 Area per panel 800 in / 5.55 ft 2 Panels per Square: 20 (including overlap, for a 100 ft covered area)
More informationDIRECTIONS FOR APPLICATION
Instructions 1 General NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE DIRECTIONS
More informationTHIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE
BRANZ Appraised Appraisal No. 547 [2007] NURALITE Nuralite Waterproofing Ltd. 53A Victoria Street, Onehunga, Auckland 1061, Zealand TEL: (64) (9) 579-2046 FAX: (64) (9) 579-5136 email: info@nuralite.co.nz
More informationDIRECTIONS FOR APPLICATION
Instructions 1 General NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE DIRECTIONS
More informationDIRECTIONS FOR APPLICATION
Instructions 1 General NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE DIRECTIONS
More informationGLOSSARY. A useful collection of definitions for commonly used terms in tile roofing.
A useful collection of definitions for commonly used terms in tile roofing. Abutment Where the roof tiles meet a structure rising above the roof. Accessory A concrete or terracotta product used to finish
More informationSuperFOIL Insulation. Solutions Guide. Pitched Roof - Under Rafter
SuperFOIL Insulation Solutions Guide Pitched Roof - Under Rafter SF19+ Pitched Roof Under Rafter Solutions CONSTRUCTION THICKNESS R -VALUE EXTERNAL SURFACE - 0.040 TILES / SLATES 10mm - BATTEN CAVITY 25mm
More informationA P P L I C A T I O N I N S T R U C T I O N S
1 2 3 General Instructions NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE
More informationSLATE & SHINGLE INSTALLATION
EAVE EDGE Apply a small strip of roofing paper to the bottom of eave. Eave flashing is attached to substrate with roofing nails every 9". Install underlayment over entire roof. (See Fig. 1) PAGE 1 Bend
More informationInspire Aledora Slate Application Guidelines
July 2014 Inspire Aledora Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry bar,
More informationBARDOLINE INSTALLATION INSTRUCTIONS
BARDOLINE INSTALLATION INSTRUCTIONS www.onduline.com CONTENTS General conditions Material requirements Terms Estimating shingle requirements Roof preparation Shingle application 9 GENERAL CONDITIONS ONDULINE
More informationSG-30 A P P L I C A T I O N I N S T R U C T I O N S. Directions For Application
1 2 3 General Instructions NOTICE: THESE SHINGLES MUST BE APPLIED TO CONFORM WITH ALL APPLICABLE BUILDING CODES. THESE DIRECTIONS REPRESENT COMMON AND ACCEPTED ROOFING PRACTICES. DEVIATIONS FROM THESE
More information1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and Highlights
1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and s These 1 Exam Prep Tabs are based on the National Roofing Contractors Association (NRCA) manual listed below: Steep-Slope Roof Systems
More informationHatteras Shingles. CertainTeed Shingle Applicator s Manual. YOUR OBJECTIVE: To learn the correct procedures for installing Hatteras shingles
CertainTeed Applicator s Manual Hatteras s 14 YOUR OBJECTIVE: To learn the correct procedures for installing Hatteras shingles HATTERAS SHINGLES Hatteras shingles are a premium oversize (18" x 36") roofing
More informationTuff-Rib Install Guide
Install Guide bestbuymetalroof.com Page 2 of 27 Page 3 of 27 1. Page 4 2. a. Installation Guide b. Panel Squaring Pages 5, 6 Pages 7, 8 3. Pages 9, 10 4. a. Fascia (optional) b. Eave / 1.5x3.5 Angle c.
More informationAcceptable Standards of Domestic Construction
Truss or Rafter Roof Batten Triple grip fastener (for roof trusses) Foil lined Insulation blanket Top plate Sprocket Brick tie Top plate strapping at 1200mm max. cts. Note: Holding down straps should be
More informationAQUAGARD EPDM FLAT ROOFING SYSTEMS INSTALLATION GUIDE THE MECHANICALLY FIXED SYSTEM
AQUAGARD EPDM FLAT ROOFING SYSTEMS INSTALLATION GUIDE THE MECHANICALLY FIXED SYSTEM The following guide covers the technique for the Mechanically Fixed System. This system is best employed when an overlay
More informationAPRON FLASHING NOTES: SHEET METAL APRON FLASHING WITH HEMMED EDGE RAGGLE SEALANT UNDERLAYMENT TURNED UP WALL
SHEET METAL APRON FLASHING WITH HEMMED EDGE SEALANT SHEET METAL COUNTERFLASHING (SEE NOTE No.1) RAGGLE UNDERLAYMENT TURNED UP WALL SHEET METAL STEP FLASHING SOLDER OR SEAL CORNERS ASPHALT SHINGLES NOTES:
More informationBUILDERS RESPONSIBILITY
BUILDERS RESPONSIBILITY August 2015 Key Builder Responsibilities Before roof tiles can be loaded onto the roof frame, the following must be completed unless otherwise specified in the roof contract: 1.
More informationMETRO PANELS (EXPOSED
METRO PANELS 001EX-METRO-PANELS.VSD STARTER EAVE Detail Metro V-Bat RISER METAL (1) PANELS (2) FASTENERS (5) BOTTOM ROW fastening 0.75in. (4) METRO RISER Metal, With Integral Batten Riser & Locator-Lip.
More informationTable of Contents Light Gauge Metal Roof & Wall Panels
Table of Contents Light Gauge Metal Roof & Wall Panels Installation Guide for Delta Rib, Nor-Clad, Strata Rib & 2-1/2 Corrugated Introduction Important Notice Notes: April 2008 Minimum Recommended Tools
More informationTECHNICAL BULLETIN 28
November 2015 TECHNICAL BULLETIN 28 INCLINED PREFORMED GRP VALLEY TROUGHS 1. BACKGROUND 1.1 Preformed GRP (Glass Reinforced Polyester) Valley Troughs have been used successfully in the roofing industry
More informationPolytegola N. Bitumen Roof shingles. Application guide
Polytegola N Bitumen Roof shingles Application guide Application manual POLYTEGOLA N CONTENT 1. Foreword - General conditions 3 2. POLYTEGOLA N designs 4 3. Roof pitches 5 4. Storage 5 5. Roof decking
More informationINSTALLATION WARNING! These install details are provided to demonstrate a recommended installation method for Metro Roof panels and accessories.
Issued December 29, 2005 evised July 5, 2013 INSTALLATION WANING! These install details are provided to demonstrate a recommended installation method for Metro oof panels and accessories. practices used
More informationROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION
ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION 1. Scope 4. Underlayment 2. 1.1 This roofing application standard has been developed to provide a responsive
More informationROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION
ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION 1. Scope 4. Underlayment 2. 1.1 This roofing application standard has been developed to provide a responsive
More informationENGINEERED SLATE 2018 INSTALLATION GUIDE
ENGINEERED SLATE 2018 INSTALLATION GUIDE Table of Contents Contact Information Page 2 General Product Details Page 3 Code Compliance Page 3 Adhesives and Sealants Page 3 General Design Details Page 3
More informationMetroCOTTAGE Shingle
Batten-less Installation Sept. 14, 2017 INSTALLATION WARNING! These install details are provided to demonstrate a recommended installation method for Metro Roof panels and accessories. used in the United
More informationCertainTeed. Shake / Slate Installation Guide
CertainTeed Shake / Slate Installation Guide Table of Contents System Components... 2 General Conditions, Safety and Roof Preparations... 3... 4 Eave/Drip Edge... 5 Inner Gable... 6 Outer Gable... 7 Open
More informationInstallation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation
Step 7. Transition s and Accessories Step 3. Valley Step 6. Hip and Ridge Installation Step 2. Rake Trim Step 5. Installing the Shingles Step 1. Eave Starter Installation Step 4. Endwall s Installation
More information3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25
3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25 1 Directions For Applying Malarkey 3-Tab Shingles GENERAL INSTRUCTIONS Install Malarkey 3-tab shingles according to building code and local amendments.
More informationPROFESSIONAL PITCHED ROOFING ANCILLARIES
PROFESSIONAL PITCHED ROOFING ANCILLARIES MADE IN BRITAIN Before installing the Easy Roof System, please be aware of the following guidelines: The roof should be installed in the traditional way, with the
More informationInspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square
December 2017 Classic Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry bar,
More informationInstallation Instructions
Installation Instructions ROLL VENT STANDARD / METRIC Page Installation Considerations 3 Roll Vent Standard General Installation 4 Roll Vent Metric General Installation 5 Steep Pitch Guidelines 6 Asphalt
More informationROOFING APPLICATION STANDARD (RAS) No. 130
ROOFING APPLICATION STANDARD (RAS) No. 130 1. Scope 1.1 This application Standard provides the minimum installation criteria for wood shingles and shakes. 2. Definitions 2.1 For definitions of terms used
More informationTurada Hardwood Shingles and Shakes Installation instructions
1. General 1.1 Maximum Exposure: Maximum exposure for wood shingles and shakes shall comply with Table 1 herein, unless specifically specified in the roof assemblies Product Approval. 1.2 Solid and Spaced
More informationONDUVILLA. The Attractive Alternative to Shingles I N S T A L L A T I O N I N S T R U C T I O N S
ONDUVILLA The Attractive Alternative to Shingles I N S T A L L A T I O N I N S T R U C T I O N S 1 INSTALLATION INSTRUCTIONS Even though ONDUVILLA is easy to install, it is important to read through these
More informationHERITAGE LAMINATED ASPHALT SHINGLES Frederick, MD
Application Instructions for FORMERLY 30 THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR
More informationCambridge English Application Instructions
Cambridge English Application Instructions ROOF SLOPE: Never apply asphalt shingles to roof slopes less than 2:12. For slopes 2:12 to 4:12 (LOW SLOPE), see special underlayment requirements outlined below.
More informationTerrabella Shake & Shingle Znap Ver. 2.0
Terrabella Shake Znap Actual length = 52.6 Actual Width = 16.33 Coverage length = 49.7 Coverage width = 14 Terrabella Shingle Znap Actual Length = 52.375 Actual Width = 15.25 Coverage Length = 49.375 Coverage
More informationBitumen Roofshingles ARMOURVENT MULTI APPLICATION GUIDE VENTILATION
Bitumen Roofshingles ARMOURVENT MULTI APPLICATION GUIDE VENTILATION WHY VENTILATE A SHINGLE ROOF? Unventilated shingle roofs will cause high temperatures inside. This will age the shingles much quicker
More informationNEW equinox INSTALLATION GUIDE Issue
NEW equinox INSTALLATION GUIDE Issue 1 CONTENTS If in doubt at any stage 1. Preparing the ring beam 2 2. Installing the framework 3 3. Insulation and waterproofing 7 4. Tile application: Steel tiles 9
More informationThe Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA
TRS 9 35MM 78MM 150MM 78MM THICKNESS END SPAN INTERNAL SPAN MINIMUM PITCH 0.55MM 2.30M 3.20M 3 DESCRIPTION TRS 9 profile is designed for commercial and industrial roofing. The profile is suitable for low
More information3-Tab Shingle Installation Instructions
3-Tab Shingle Installation Instructions WWW.MALARKEYROOFING.COM Directions for Applying Malarkey 3-Tab Shingles GENERAL INSTRUCTIONS Install Malarkey 3-tab shingles according to adopted building code and
More informationSteel Roofing & Siding INSTALLATION GUIDE
Steel Roofing & Siding INSTALLATION GUIDE Your Authorized Dealer is: WASHINGTON Auburn (800) 700-7228 WASHINGTON Spokane (866) 321-5954 www.nuraymetals.com CALIFORNIA Redlands (800) 806-8729 CONTENTS BEFORE
More informationPREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS
Application Instructions for FORMERLY 50 THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR
More informationTable of Contents. Roof to Head Wall w/ Side Flashing DECRA Shake XD Roof Overview Roof Penetration - Pipes & Vents...
Table of Contents DECRA Shake XD Roof Overview.... 2 DECRA Shingle XD Roof Overview.... 3 Introduction... 4 Safety... 4 Tools.... 4 Estimating Sheet... 4 Codes & Requirements... 4 Roof Slope... 4 Underlayment...
More informationHILAND TRAY FORM AND FUNCTION MATERIAL SPECIFICATIONS DESIGN GUIDE ROOFING I WALLING
HILAND TRAY ROOFING I WALLING DESIGN GUIDE FORM AND FUNCTION Hiland Tray is a modern 455mm wide tray roofing and walling system, roll formed onsite with a mobile roll forming facility in long single lengths
More informationDETAIL MANUAL for Standing Seam / Image II
DETAIL MANUAL for Standing Seam / Image II Best Buy Metals Toll Free 1-800-728-4010 / Phone 423-479-6382 / Fax 423-728-3066 www.bestbuymetals.com Best Buy Metals Standing Seam Roofing Panels Fig. 2 Standing
More informationIRONWOOD SHAKE & FLASHING SPECIFICATIONS
3 1-51 3-3/4 1 IRONWOOD SHAKE & FLASHING SPECIFICATIONS 6 1-13- 1-1-1/4 2-1.5 Drip Edge 2.5 Drip Edge 2-7/8 1-1-1/4 3/4 1 2-1 IRONWOOD SHAKE Overall Length 51 Length of Coverage 48 Width of Coverage 1
More informationLaminate Shingle Installation Instructions
Laminate Shingle Installation Instructions WWW.MALARKEYROOFING.COM Directions for Applying Malarkey Laminate Shingles GENERAL INSTRUCTIONS Install Malarkey laminate shingles according to adopted building
More informationIRONSTONE SLATE & FLASHING SPECIFICATIONS IRONSTONE SLATE
8 5/8" A) 1 5/8" 5/8" 1 10" 10 1 5 50" 9 7/8" IRONSTONE SLATE & FLASHING SPECIFICATIONS IRONSTONE SLATE 1/8" 1 B) 3/8" 2 7/8" 1 3/8" 3/8" 3/8" 3/8" 1" 1 5/8" 1 5/8" 1 2 1 8.3" 3/4" Overall Length 52 Length
More informationNEW equinox INSTALLATION GUIDE Issue
NEW equinox INSTALLATION GUIDE Issue 2 CONTENTS 1. Preparing the ring beam 2 2. Installing the framework 3 3. How to install structural support posts 7 4. Insulation and waterproofing 8 5. Tile application:
More informationShingle Installation Guidelines
Shingle Installation Guidelines General Guidelines Materials to be used Key definitions Cost of roofing Preparation of the roofing deck Materials used for roofing should conform to approved norms and regulations
More information15 YEAR GUARANTEE. Tough and long lasting Guaranteed waterproof for 15 years Economical and easy to fix AVAILABLE IN A RANGE OF COLOURS
INSTALLATION GUIDE AVAILABLE IN A RANGE OF COLOURS 15 YEAR GUARANTEE Tough and long lasting Guaranteed waterproof for 15 years Economical and easy to fix Coroline corrugated bitumen sheet is a tough lightweight
More informationROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION
ROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION 1. 2. 3. Scope 1.1 This application standard provides the minimum installation criteria for wood
More informationArmourvent Multi application guide
application guide CONTENTS Why ventilate a shingle roof 2 A balanced system: the key to proper roof ventilation 3 Calculating the net free area of vent openings 4 Installation of IKO 6 Ridge vent installation
More informationInstallation Guide GRP Dormer
Installation Guide GRP Dormer To ensure optimum performance please follow the correct fitting procedures outlined in this installation guide. Site safety and good building practice should be adhered to
More informationINSTALLATION GUIDE LEARN MORE AT DECRA.COM
Villa Tile INSTALLATION GUIDE LEARN MORE AT DECRA.COM Table of Contents DECRA Villa Tile Roof Overview... 2 Introduction... 3 Safety... 3 Tools.... 3 Estimating Sheet... 3 Codes & Requirements... 3 Roof
More informationinstallation guide Villa
installation guide Villa Table of Contents Introduction............................. 2 Safety................................... 2 Tools.................................... 2 Codes & Requirements....................
More informationAIA Specification. Section Slate Shingles PART 1 GENERAL
AIA Specification Section 07315 Slate Shingles PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationApplication Guidelines - Slate General Information
No Special Tools Required Application Guidelines - Slate General Information hand fastened or fastened with a pneumatic nail gun utility knife or a standard circular saw tape measure, pry bar, tin snips
More informationINSTALLATION DETAILS
INSTALLATION DETAILS Front Issued January 23rd, 2005 These install details are provided to demonstrate the recommended installation method for Metro Roof products and accessories. The details and information
More informationThe stylish light weight bitumen shingle tile strip roofing system Design and installation manual
CI SfB (4-) Nn2 BARDOLINE Shingles By Onduline The stylish light weight bitumen shingle tile strip roofing system Design and installation manual Complementary leaflet to the Bardoline instructional film
More informationTechnical Information
Product: Owens Corning Asphalt Roofing Shingles are a glass-fibre reinforced asphalt shingles surfaced with a ceramic coated mineral chip to provide protection from UV rays. The shingles, flashings and
More informationBest Buy Metals Toll Free / Phone / Fax
DETAIL MANUAL for Vertical Seam Best Buy Metals Toll Free 1-800-728-4010 / Phone 423-479-6382 / Fax 423-728-3066 www.bestbuymetals.com Vertical Seam Roofing Panels Fig. 2 Vertical Seam Has 1-3/4" high
More informationRoll-Fix Kit The complete dry hip kit RFIG
H I P Roll-Fix Kit The complete dry hip kit RFIG.045-0906-1 Roll-Fix is a quick and simple dry-fix roofing kit for hips. l Quick and easy to install no special tools required l Universal application fits
More informationInstallation Manual. Future Roof Shingle / Slate Products
Installation Manual Future Roof Shingle / Slate Products REVISED 14/09/2010 Future Roof Shingle Installation Manual is a component of Future Roof, Inc. and as such is intended to be used with Future Roof
More informationInstallation Instructions
Installation Instructions RAPID RIDGE STANDARD / 7 / METRIC Page Installation Considerations 3 Rapid Ridge Standard General Installation 4 Rapid Ridge Metric General Installation 5 Rapid Ridge 7 General
More informationeco-shake INSTALLATION INSTRUCTION
1 eco-shake INSTALLATION INSTRUCTION NOTE: Shuffling the eco-shakes during installation may be necessary to obtain a uniform color throughout the roof. Due to the natural wood content in the ecoshakes,
More informationFLASHING: VALLEYS, WALLS, CHIMNEYS, ETC.
C E R T A I N T E E D S H I N G L E A P P L I C A T O R S M A N U A L 6 FLASHING: VALLEYS, WALLS, CHIMNEYS, ETC. YOUR OBJECTIVE: To learn CertainTeed-recommended flashing installation methods and ways
More informationC e r t a i n T e e d S h i n g l e A p p l i c a t o r s M a n u a l. and Carriage House STEEP. Slope Application. (over 21/12)
C e r t a i n T e e d S h i n g l e A p p l i c a t o r s M a n u a l Grand Manor 16 and Carriage House YOUR OBJECTIVE: To learn the correct method of installing each of these roofing products. These shingles
More informationTuff-Rib. Installation Manual. Nationwide supplier of quality metal roofing. Toll-Free (800) S. Lee Hwy. Cleveland, TN 37311
Installation Manual Nationwide supplier of quality metal roofing. 65 S. Lee Hwy. Cleveland, TN 7.. www.bestbuymetals.com Toll-Free (800) 78-00 IMPORTANT NOTICE This manual contains suggestions and guidelines
More informationInstallation Manual. For Gerard Shingle Products
Installation Manual For Gerard Shingle Products Gerard Shingle Installation Manual is a component of Gerard roofing products and as such is intended to be used with Gerard products only. All information
More informationHow-To-build guide Garden shed
How-To-build guide Garden shed What you can build using this guide This guide will show you how to build a re-locatable garden shed. Before you begin building Contact your local territorial authority to
More informationThermoSpan EPS. Metalcraft COMMERCIAL ROOFING CREPS. Insulated Panel Systems DETAIL LIST
ThermoSpan EPS DETAIL LIST 00 / 15 COVER SHEET 01 / 15 RIDGE DETAIL 02 / 15 HEAD FLASHING DETAIL 03 / 15 EAVES GUTTER DETAIL 04 / 15 INSULATED GUTTER 05 / 15 INSULATED BOX GUTTER 06 / 15 BARGE CAPPING
More informationRecommended Slating Tools
Recommended Slating Tools Product Size L Sketch of Article No. Description 60-070 Scriber 60-00 Slater s Hammer 60-00 Slater Ripper 60-080 Parallel Shears 60-0 Slate Cutter Kwiksnip Slate Guuillotine Slate
More informationSystem for 2+ Level Buildings
Issued Sept 205 Contact Info@symonite.co.nz System for 2+ Level Buildings Typical Details Issued: September 205 TYPICAL DETAILS CONTENTS.0 TYPICAL VERTICAL JOINTS 2.0 EXT. CORNER / TYPICAL HORIZONTAL JOINT
More informationBBA BRITISH BOARD OF AGREMENT CERTIFICATE NO. 87 / 1823 / C
Fixing Guide BBA BRITISH BOARD OF AGREMENT CERTIFICATE NO. 87 / 1823 / C Onduline Fixing Guide Introduction Onduline is the world s largest manufacturer of bituminous corrugated sheets. Onduline roofing
More informationA REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS
WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME
More informationequinox INSTALLATION GUIDE Issue CONTENTS If in doubt at any stage BE SAFE WHEN WORKING AT HEIGHT
equinox INSTALLATION GUIDE Issue 3 CONTENTS 1. Preparing the ring beam 2 2. Installing the eaves beam 3 3. How to install structural support posts 7 4. Insulating and waterproofing 8 5. Tile application:
More informationGerard Installation Manual Shingle Profiles
Gerard Installation Manual Shingle Profiles Granite Ridge Shingle Guardian Shingle March 2017 This Installation Manual is designed as an instructional tool to clearly depict to the contractor, installer,
More informationStone coated steel roof tile INSTALLATION GUIDE
Stone coated steel roof tile INSTALLATION GUIDE Ⅰ. Introduction These installation details are provided to demonstrate recommended installation methods for KD One roof products and accessories. Consult
More informationTable of Contents. Installation Guide for Profile with Hidden Fasteners 3. Installation Steps 4, 5. Prestige Series Moldings 6, 7. Other Accessories 8
1 Table of Contents Page(s) Installation Guide for Profile with Hidden Fasteners 3 Installation Steps 4, 5 Prestige Series Moldings 6, 7 Other Accessories 8 Trims & Accessories 9 Eave Starters 10 Gableboards
More informationViva Synthetic Thatch Installation Instructions
Viva Synthetic Thatch Installation Instructions Overview Structure This instruction manual is for the installation of VIVA on an open battened roof frame. Structure should be framed with weatherable wood
More informationStormMaster Slate General Instructions 1.) GENERAL INSTRUCTIONS 2.) ROOF DECK VENTILATION 3.) ROOF DECK
StormMaster Slate General Instructions IMPORTANT: THE STATEMENTS EXPRESSED ON THIS PAGE ARE THE RECOMMENDATIONS FOR THE APPLICATION OF THE ROOFING PRODUCTS AS OUTLINED AND ILLUSTRATED. ANY DEVIATION FROM
More information