CONTENTS LOAD CELLS / FORCE TRANSDUCERS TR CM CU AM TC TU TH CC CT SB SH CB OC OD CIR CIR-D

Size: px
Start display at page:

Download "CONTENTS LOAD CELLS / FORCE TRANSDUCERS TR CM CU AM TC TU TH CC CT SB SH CB OC OD CIR CIR-D"

Transcription

1 CONTENTS LOAD CELLS / FORCE TRANSDUCERS TR CM CU AM TC TU TH CC CT SB SH CB OC OD CIR CIR-D

2 3 TR FORCE TRANSDUCER FOR MEASURING THE TENSION ON FIXED OR ROTATING SPINDLES Main features Range of measurement: from 00 N to kn Accuracy class: 0,5% Corrosion resistant Internally generated calibration signal Orientation of the axis of maximum sensitivity for 35 independently from the position of the fixing holes Grade of protection: IP65 (DIN 40050) Integrated protection against overloads TR series force transducers are used to measure the tension that plastic films or tapes exert on the guide rollers of the machinery used to coil them. Mounted at the ends of a fixed or transmission shaft on the machine chassis, they perform the function of force sensors and bearing for the ends of the shaft. They are used on both fixed and rotating shafts. TR transducers are supplied with the adaptor flange for fixing, with 4 M6 screws or with one central M0 or M2 screw. TECHNICAL DATA Accuracy Nominal full scale load (Ln) Nominal output at FSO Output tolerance at Ln Combined errors: Non linearity Histeresis, Repeatibility Creep (after 30 min. at Ln) 0,5% 00N...kN 2mV/V <± % FSO < ± 0,5% FSO < ± 0,06% FSO MECHANICAL DIMENSIONS Model for rollers with revolving hub. Neoprene Sleeve Zero load out of balance signal < ± % FSO Thermal drift in compensated range Sensitivity Zero Calibration < ± 0,005% FSO C < ± 0,0% FSO C - FLA705 Std Flange 4 seats for M6 fixing screws of the cover N 4 M6 case screws to prevent the bearing support from rotating. Nominal bridge resistance Isolation resistance 350 Ohm > 0 GOhm VPT02A0-6PT2 CONNECTOR Direction of the axis of max. sensitivity of the load cell (Indicated by a red dot on the bearing support). Nominal supply voltage Maximum supply voltage Compensated temperature range Maximum temperature range 0V 5 V C C Model for rollers with fixed hub. Neoprene Sleeve Storage temperature range C Permitted static load Maximum applicable load 00% Ln 300% Ln FLA705 Std Flange 4 seats for M6 fixing screws of the cover N 4 M6 case screws to prevent the bearing support from rotating. Rupture load Maximum static lateral load Maximum elastic deformation at Ln > 500% Ln 50% Ln < 0,5 mm VPT02A0-6PT2 CONNECTOR N 4 M6x20 screws for tightenning the half shells of the fixed hub support. Direction of the axis of max. sensitivity of the load cell (Indicated by a red dot on the bearing support). Grade of protection (DIN40050) IP65 Moving Half-shell Fixed Half-shell Electr. connections: Connector Elastic element material Case material VPT02A0-6PT2 Anodised aluminium Anodised aluminium (Flange and bearing in AISI 303) Cuscinetto 35x5 H 40x7 H2 øa 37 42,5 B 4,5 4,25 øc ød Valori delle misure in millimetri (± 0,) Coppia di serraggio consigliata per le viti di fissaggio M6 di 7Nm E,6,85

3 ELECTRICAL CONNECTIONS CABLE OUTPUT CABLE CONNECTION EXCITATION EXCITATION VPT02A0-6PT2 CONNECTOR If the transducer is supplied complete with prewired connection cable, the colour code is that indicated in the table. Cells connected in parallel Yellow- Yellow- SHUNT BOX In systems that use several cells, the parallel connection automatically sums the loads on each individual cell. Using this method of measurement, the maximum load will be the sum of the loads on the individual cells and the sensitivity will be the average value of these cells. It is important that the user ensures that no cell is stessed beyond its maximum rating under any load condition. CONVERSION TABLE Kg N Lb

4 FLANGE Standard adaptor flange (see mechanical dimensions drawing) Central fixing Central fixing FLA705 FLA7 FLA75 FLA7 SEAT FOR M0* FIXING SCREW OF THE COVER FLA75 SEAT FOR M2* FIXING SCREW OF THE LOAD CELL TO CARTER * Recommended torque 75Nm 4 SEATS FOR M6 FIXING SCREW OF THE SUPPORT 4 SEATS FOR M6 FIXING SCREW OF THE SUPPORT OPTIONAL ACCESSORIES Radial bearing with stop ring (UNI ) and spacer 35 mm PKIT mm PKIT 600 Female cable connector Grade of protection IP65 CON pin connector with 8m (25ft) cable C08W 6-pin connector with 5m (50ft) cable C5W 6-pin connector with 25m (75ft) cable C25W 6-pin connector with 30m (00ft) cable C30W Other lengths consult factory Cable colour code Conn. wires A B C D E F Black Blue Orange TR application manual DOC467 ORDER CODE Force transducer TR MEASUREMENT RANGE (N) 0-00 NC N2C N3.5C N5C N7.5C NM If request, it is possible to supply models with non-standard mechanical and/or electrical features. 2 3 FLANGE FLA 705 (standard) FLA7 FLA75 EXTERNAL DIAMETER 35 mm bearing C35 40 mm bearing C40 30 mm shaft spindle P30 Ex.: TR-N3.5C-C40- TR force transducer, measurement range 350N, external bearing diameter of 40mm with normal mounting and standard flange. GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice. GEFRAN spa via Sebina, PROVAGLIO D ISEO (BS) - ITALIA ph fax Internet: cod. TR - 09/04

5 CM LOAD CELL FOR COMPRESSION APPLICATIONS Main features Range of measurement: from 00 to Kg Accuracy class: 0,% All stainless steel construction Corrosion resistant Internally generated calibration signal Grade of protection: IP67 (DIN 40050) TECHNICAL DATA Accuracy Nominal full scale load (Ln) Nominal output at FSO Output tolerance at Ln Combined errors: Non linearity Histeresis, Repeatibility Creep (after 30 min. at Ln) Zero load out of balance signal Calibration signal * Thermal drift in compensated range Nominal input resistance Nominal output resistance Isolation resistance Nominal supply voltage Maximum supply voltage Sensitivity Zero Calibration Compensated temperature range Maximum temperature range Storage temperature range Permitted static load Permitted dinamic load Maximum applicable load Rupture load Maximum elastic deformation at Ln Grade of protection (DIN40050) Electr. connections: Connector Screened cable Elastic element material 0,% Kg 2mV/V <± 0,2% FSO < ± 0,% FSO < ± 0,06% FSO < ± % FSO 80%FSO ± % < ± 0,0% FSO C < ± 0,0% FSO C < ± 0,0% FSO C 700 Ohm 700 Ohm > 0 GOhm 0 V 5 V C C C 30% Ln 00% Ln 50% Ln > 300% Ln < 0,2 mm Cable: IP67 Connector: IP65 VPT02A0-6PT2 6x0,25 / 5 m. Stainless steel * The exact value is indicated on the instrument nameplate CM series load cells are strain gauge transducers used to measure loads in static and dynamic applications, in compression, with high accuracy. They are machined from a single block of metal, so the primary sensing element, the mountings and the case contain no welds allowing smaller dimensions and an enhanced grade of protection. The configuration of the point of measurement, with 8 strain gauges, reduces errors caused by imperfect applications of the load. Typical applications of load cells connected in parallel are: silos, hoppers, large weighing platforms. The stainless steel construction is suitable for use in aggressive environments in the chemical and petrochemical industries. MECHANICAL DIMENSIONS ø A ø B ø C ø D E H K L L L2 ø M ø N R VITI Nm* ,5 0,5 00 6,7 5,7 45,7 30 3, XM6 9 BALL R Ln (Kg) ,5 0,5 6, ,5 2,5 5,5 30 3, XM6 60 BALL R , , XM2 00 LOAD INTRODUCTION DIRECTION , XM6 200 Dimensions mm. (± 0,) * Recommended torque with UNI 593 screws of resistance class 0.9 according to UNI 3740.

6 ELECTRICAL CONNECTIONS CONNECTOR OUTPUT CABLE OUTPUT + - EXCITATION + EXCITATION - CALIBRATION SHUNT Black Blue-Orange 6x0.25 Screened cable VPT02A0-6PT2 MALE CONNECTOR If the transducer is supplied complete with prewired connection cable, the colour code is that indicated in the table. * The screen is isolated from the transducer body. It is recommended that the ground is connected at the instrument end. Cells connected in parallel Yellow- Yellow- Yellow- SHUNT BOX In systems that use several cells, the parallel connection automatically sums the loads on each individual cell. Using this method of measurement, the maximum load will be the sum of the loads on the individual cells and the sensitivity will be the average value of these cells. It is important that the user ensures that no cell is stessed beyond its maximum rating under any load condition. CONVERSION TABLE Kg N Lb

7 OPTIONAL ACCESSORIES Female cable connector Grade of protection IP65 CON pin connector with 8m (25ft) cable C08W 6-pin connector with 5m (50ft) cable C5W 6-pin connector with 25m (75ft) cable C25W 6-pin connector with 30m (00ft) cable C30W Other lengths consult factory Cable colour code Conn. A B C D E F wires Black Blue Orange Self alignement plate (Max. inclination 3 ) NOMINAL LOAD Kg ø A ø B ø C D F E COD ,25 PIA ,5 PIA PIA PIA703 Dimensions mm. (± 0,) ORDER CODE Load cell CM MEASUREMENT RANGE (Kg) KC K2C K3.5C K5C K7C KM K2M K3.5M K5M K7M K0M K20M K30M K50M If request, it is possible to supply models with non-standard mechanical and/or electrical features. S R SENSITIVITY 2mV/V version 3mV/V version (range Kg) only ELECTRICAL CONNECTIONS 6x0,25 5m screened cable F VPT02A0-6PT2 connector C Ex.: CM - K0M - F - S CM load cell, range kg, cable connection and 2mV/V standard sensitivity. GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice. GEFRAN spa via Sebina, PROVAGLIO D ISEO (BS) - ITALIA ph fax Internet: cod. CM - 09/04

8 CU COMPACT LOAD CELL FOR COMPRESSION APPLICATIONS Main features Range of measurement: from 50 to.000 kg Accuracy class: 0,2% All stainless steel construction Corrosion resistant Grade of protection: IP67 (DIN 40050) Compact size The CU range of load cells are designed for the measurement of static or dynamic loads in compression. All the transducers are calibrated as load cells in units of mass (Kg). The CU series is supplied for nominal loads from 50Kg to t. This model has an IP67 protection degree so it can be used in aggressive atmospheres often found in the chemical industries. The transducer body is machined from a single piece of stainless steel with no welding. This means that it is highly resistant to mechanical shock and vibration. The compact size means that these cells can be placed in positions that are difficult to acess and where little space is available. TECHNICAL DATA Accuracy Nominal full scale load (Ln) Nominal output at FSO Output tolerance at Ln Combined errors: Non linearity Histeresis, Repeatibility Creep (after 30 min. at Ln) Zero load out of balance signal Thermal drift in compensated range Nominal input resistance Nominal output resistance Isolation resistance Nominal supply voltage Maximum supply voltage Sensitivity Zero Calibration Compensated temperature range Maximum temperature range Storage temperature range Permitted static load Permitted dinamic load Maximum applicable load Rupture load Maximum elastic deformation at Ln Grade of protection (DIN40050) Electr. connections screened cable Elastic element material 0,2% kg 2mV/V <± 0,2% FSO < ± 0,2% FSO < ± 0,06% FSO < ± % FSO < ± 0,0% FSO C < ± 0,0% FSO C Ohm 350 Ohm > 0 GOhm 0 V 5 V C C C 30% Ln 00% Ln 50% Ln > 300% Ln < 0,2 mm IP67 4x0,25 / 5 m. Stainless steel MECHANICAL DIMENSIONS SCREENED CABLE BALL R 60 LOAD INTRODUCTION DIRECTION 4 equidistant holes Dimensions mm. (± 0,) * Recommended torque ** UNI 593 screws of resistance class 0.9 according to UNI 3740

9 ELECTRICAL CONNECTIONS ORDER CODE CABLE EXIT Load cell CU 4x0.25 Screened cable EXCITATION EXCITATION SHIELD Yellow- MEASUREMENT RANGE (kg) K5D KC K2C Shield K5C KM If request, it is possible to supply models with non-standard mechanical and/or electrical features. Yellow * The screen is isolated from the transducer body. It is recommended that the ground is connected at the instrument end. Ex.: CU - K5D CU load cell, measurement range 0-5 0kg. Cells connected in parallel Yellow- Yellow- Yellow- SHUNT BOX In systems that use several cells, the parallel connection automatically sums the loads on each individual cell. Using this method of measurement, the maximum load will be the sum of the loads on the individual cells and the sensitivity will be the average value of these cells. It is important that the user ensures that no cell is stessed beyond its maximum rating under any load condition. CONVERSION TABLE Kg N Lb GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice. GEFRAN spa via Sebina, PROVAGLIO D ISEO (BS) - ITALIA ph fax Internet: cod. CU - 09/04

10 AM MINIATURE FORCE TRANSDUCER FOR COMPRESSION APPLICATIONS Main features Range of measurement: from 5 to 20 kn Accuracy class: % All stainless steel construction Corrosion resistant Grade of protection: IP65 (DIN 40050) Small size The AM force transducers series have been designed to measure static and dynamic compression forces. They are particularly suitable for monitoring pounding operations in compression which require a rugged transducer, insensitive to high resonance frequencies caused by nonhomogeneous leads in dynamic sequences. The accuracy and the stability are not affected by continuous cycling under harsh conditions even with dynamic loads. The small size of the AM force transducers makes them ideal for retrofitting in existing equipment. TECHNICAL DATA MECHANICAL DIMENSIONS Accuracy % Nominal full scale load (Ln) kn Nominal output at FSO Output tolerance at Ln Combined errors: Non linearity Histeresis, Repeatibility Creep (after 30 min. at Ln) 2mV/V <± 5% FSO < ± % FSO < ± 0,2% FSO BALL R 40 LOAD INTRODUCTION DIRECTION SCREENED CABLE Zero load out of balance signal < ± % FSO Thermal drift in compensated range Sensitivity Zero Calibration < ± 0,02% FSO C < ± 0,04% FSO C - Nominal bridge resistance 350 Ohm Isolation resistance > 0 GOhm Nominal supply voltage 0 V Maximum supply voltage 5 V Compensated temperature range C Maximum temperature range C Storage temperature range C Permitted static load 30% Ln Permitted dynamic load 00% Ln Maximum applicable load 50% Ln Rupture load > 300% Ln Maximum static lateral load 40% Ln Maximum elastic deformation at Ln < 0,2 mm Grade of protection (DIN40050) IP65 Electr. connections screened cable Elastic element material 4x0,5 / 2 m. Stainless steel Dimensions mm. (± 0,)

11 ELECTRICAL CONNECTIONS OPTIONAL ACCESSORIES CABLE EXIT EXCITATION EXCITATION SHIELD Yellow- 4x0.25 Screened cable ORDER CODE Shield Force transducer AM * The screen is isolated from the transducer body. It is recommended that the ground is connected at the instrument end. Cells connected in parallel Yellow MEASUREMENT RANGE (kn) KN5U KND 0-20 KN2D If request, it is possible to supply models with non-standard mechanical and/or electrical features. Yellow- Yellow- Ex.: AM - KN5U AM force transducer with range of measurement 0-5 kn. Yellow- SHUNT BOX In systems that use several cells, the parallel connection automatically sums the loads on each individual cell. Using this method of measurement, the maximum load will be the sum of the loads on the individual cells and the sensitivity will be the average value of these cells. It is important that the user ensures that no cell is stessed beyond its maximum rating under any load condition. CONVERSION TABLE Kg N Lb GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice. GEFRAN spa via Sebina, PROVAGLIO D ISEO (BS) - ITALIA ph fax Internet: cod. AM -08/04

12 TC LOAD CELL FOR TENSION/COMPRESSION APPLICATIONS Main features Range of measurement: from00 to Kg Accuracy class: 0,2% All stainless steel construction Corrosion resistant Internally generated calibration signal Grade of protection: IP67 (DIN 40050) TECHNICAL DATA Accuracy Nominal full scale load (Ln) Nominal output at FSO Output tolerance at Ln Combined errors: Non linearity Histeresis, Repeatibility Creep (after 30 min. at Ln) Zero load out of balance signal Calibration signal * Thermal drift in compensated range Nominal input resistance Nominal output resistance Isolation resistance Nominal supply voltage Maximum supply voltage Sensitivity Zero Calibration Compensated temperature range Maximum temperature range Storage temperature range Permitted static load Permitted dinamic load Maximum applicable load Rupture load Maximum elastic deformation at Ln Grade of protection (DIN40050) Electr. connections: Connector Screened cable Elastic element material 0,2% Kg 2mV/V <± 0,2% FSO < ± 0,2% FSO < ± 0,06% FSO < ± % FSO 80%FSO ± % < ± 0,0% FSO C < ± 0,0% FSO C < ± 0,0% FSO C 700 Ohm 700 Ohm > 0 GOhm 0 V 5 V C C C 30% Ln 00% Ln 50% Ln > 300% Ln < 0,2 mm Cable IP67 Connector IP65 VPT02A0-6PT2 6x0,25 / 5 m. Stainless steel * The exact value is indicated on the instrument nameplate. TC series load cells are strain gauge transducers used to measure loads in static and dynamic applications, in tension (positive signal of output) and compression (negaitive signal of output), with high accuracy (industrial weighing, laboratory testing, automation, etc). The TC series is machined from a single block of metal, so the primary sensing element, the mountings and the case contain no welds allowing smaller dimensions and an enhanced grade of protection. The configuration of the point of measurement, with 8 strain gauges, reduces errors caused by imperfect application of the load.typical applications of load cells connected in parallel are: silos, hoppers, large weighing platforms, and with suitable accessories, suspended loads. The stainless steel construction is suitable for use in aggressive environments in the chemical and petrochemical industries. MECHANICAL DIMENSIONS ø A ø B ø C ø D E H K L L L2 M ø N wires ,5 0, ,5 M20x,5 24 6xM6 Dimensions mm. (± 0,) ,5 0,5 6, ,6 37,6 67,6 30 3,5 M24x2 30 6xM0 LOAD INTRODUCTION DIRECTION Ln (Kg) , M39x3 45 8xM M52x3 55 8xM6

13 ELECTRICAL CONNECTIONS CONNECTOR OUTPUT CABLE OUTPUT + - EXCITATION + EXCITATION - CALIBRATION SHUNT Black Blue-Orange NB.: The output signal is positive for traction loads and for calibration, and negative for compression loads. Shield * Black Blue Orange VPT02A0-6PT2 CONNECTOR Yellow or green 6x0.25 Screened cable If the transducer is supplied complete with prewired connection cable, the colour code is that indicated in the table. * The screen is isolated from the transducer body. It is recommended that the screen is connected to ground at the instrument end. Cells connected in parallel Yellow- Yellow- Yellow- SHUNT BOX In systems that use several cells, the parallel connection automatically sums the loads on each individual cell. Using this method of measurement, the maximum load will be the sum of the loads on the individual cells and the sensitivity will be the average value of these cells. It is important that the user ensures that no cell is stessed beyond its maximum rating under any load condition. CONVERSION TABLE Kg N Lb

14 OPTIONAL ACCESSORIES Female cable connector Grade of protection IP65 CON pin connector with 8m (25ft) cable C08W 6-pin connector with 5m (50ft) cable C5W 6-pin connector with 25m (75ft) cable C25W 6-pin connector with 30m (00ft) cable C30W Other lengths consult factory Cable colour code Conn. wires A B C D E F Black Blue Orange Flange and ball joint see table APPLICATION NOTES Flange mounting for suspended loads Locknut Joint NO LOAD ON THIS SURFACE Wall mounting Locknut NO LOAD ON THIS SURFACE Joint Flange Joint Nominal load M* (Nm) M2** (Nm) Flange code FLA700 FLA700 FLA70 FLA702 FLA704 Joint code SND020 SND020 SND024 SND040 SND060 Locknut recommended - - M24x2-h=0 M39x3-h=6 M52x3-h=20 * Recommended tightening torque between ball-joint and locknut or flange **Recommended tightening torque with UNI593 screws with 0.9 resistance class according to UNI3740 ORDER CODE Load cell TC MEASUREMENT RANGE (Kg) KC K2C K3.5C K5C K7C KM K2M K3.5M K5M K7M K0M K20M If request, it is possible to supply models with non-standard mechanical and/or electrical features. S R SENSITIVITY 2mV/V Version 3mV/V Version (range Kg)only ELECTR. CONNECTIONS 6x0,25 5m screened cable F VPT02A0-6PT2 Connect. C Ex.: TC - K0M - F - S TC load cell, measurement range kg, cable connection and 2mV/V standard sensitivity. GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice. GEFRAN spa via Sebina, PROVAGLIO D ISEO (BS) - ITALIA ph fax Internet: cod. TC - 09/04

15 TU COMPACT LOAD CELL FOR TENSION/COMPRESSION APPLICATIONS Main features Range of measurement: from 50 to 000 kg Accuracy class: 0,2% All stainless steel construction Corrosion resistant Grade of protection: IP67 ( norme DIN 40050) Compact size The TU range of load cells are designed for the measurement of static or dynamic loads in compression (output signal: negative) or traction (output signal: positive). All the transducers are calibrated as load cells in units of mass (Kg). The TU series is supplied for nominal loads from 50Kg to t. This model has an IP67 protection degree so it can be used in aggressive atmospheres often found in the chemical industries. The transducer body is machined from a single piece of stainless steel with no welding. This means that it is highly resistant to mechanical shock and vibration. The compact size means that these cells can be placed in positions that are difficult to acess and where little space is available. TECHNICAL DATA Accuracy Nominal full scale load (Ln) Nominal output at FSO Output tolerance at Ln Combined errors: Non linearity Histeresis, Repeatibility Creep (after 30 min. at Ln) Zero load out of balance signal Thermal drift in compensated range Nominal input resistance Nominal output resistance Isolation resistance Nominal supply voltage Maximum supply voltage Sensitivity Zero Calibration Compensated temperature range Maximum temperature range Storage temperature range Permitted static load Permitted dinamic load Maximum applicable load Rupture load Maximum elastic deformation at Ln Grade of protection (DIN40050) Electr. connections screened cable Elastic element material 0,2% kg 2mV/V <± 0,2% FSO < ± 0,2% FSO < ± 0,06% FSO < ± % FSO < ± 0,0% FSO C < ± 0,0% FSO C Ohm 350 Ohm > 0 GOhm 0 V 5 V C C C 30% Ln 00% Ln 50% Ln > 300% Ln < 0,2 mm IP67 4x0,25 / 5 m. Stainless steel MECHANICAL DIMENSIONS SCREENED CABLE BALL R60 M2 NUT (UNI5589) (CH 9 - h 7) LOAD INTRODUCTION DIRECTION 4 Holes M5 equidistants Dimensions mm. (± 0,) * Recommended torque ** UNI 593 screws of resistance class 0.9 according to UNI 3740

16 ELECTRICAL CONNECTIONS OPTIONAL ACCESSORIES CABLE EXIT Flange for applying suspended loads FLA 703 Ball joint SND022 EXCITATION EXCITATION SHIELD Yellow- APPLICATION NOTES 4x0.25 Screened cable Shield Mounting with double joint and flange for suspended loads Joint Cells connected in parallel Yellow * The screen is isolated from the transducer body. It is recommended that the ground is connected at the instrument end. Locknut NO LOAD ON THIS SURFACE Yellow- Joint Yellow- Wall mounting with ball joint. Yellow- NO LOAD ON THIS SURFACE Joint Locknut SHUNT BOX In systems that use several cells, the parallel connection automatically sums the loads on each individual cell. Using this method of measurement, the maximum load will be the sum of the loads on the individual cells and the sensitivity will be the average value of these cells. It is important that the user ensures that no cell is stessed beyond its maximum rating under any load condition. CONVERSION TABLE ORDER CODE Load cell TU MEASUREMENT RANGE (kg) K5D KC K2C K5C KM Kg N Lb If request, it is possible to supply models with non-standard mechanical and/or electrical features Ex.: TU - K5D TU load cell, measurement range 0-50 kg. GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice. GEFRAN spa via Sebina, PROVAGLIO D ISEO (BS) - ITALIA ph fax Internet: cod. TU - 09/04

17 TH FORCE TRANSDUCER FOR TENSION/COMPRESSION APPLICATIONS Main features Range of measurement: from 0 to 00 kn Accuracy class: 0,% All stainless steel construction Corrosion resistant Internally generated calibration signal Grade of protection: IP65 (DIN 40050) The TH series force transducers are ideal for systems that measure tension or compression force in industrial applications, where accuracy and reliability are important, even in harsh environments. The disposition of the (8) strain gauges of the measurement bridges uses the deformation produced by the shear force of the applied load. It is thus possible to make accurate force transducers that are rugged and insensitive to lateral loads. The transducer is machined from a solid block of stainless steel and contains no welds or joints. The electrical circuit is protected by sealed formed stainless steel plates. TECHNICAL DATA Accuracy Nominal full scale load (Ln) Nominal output at FSO Output tolerance at Ln Combined errors: Non linearity Histeresis, Repeatibility Creep (after 30 min. at Ln) Zero load out of balance signal Calibration signal * Thermal drift in compensated range Nominal input resistance Nominal output resistance Nominal supply voltage Maximum supply voltage Sensitivity Zero Calibration Compensated temperature range Maximum temperature range Storage temperature range Permitted static load Maximum applicable load Rupture load Carico statico laterale max. Maximum elastic deformation at Ln Grade of protection (DIN40050) Electr. connections: Connector Elastic element material Case material 0,% kn 2mV/V <± % FSO < ± 0,% FSO < ± 0,06% FSO < ± % FSO 80%FSO ± % < ± 0,02% FSO C < ± 0,02% FSO C < ± 0,02% FSO C 700 Ohm > 0 GOhm 0 V 8 V C C C 30% Ln 50% Ln > 300% Ln 50% Ln < 0, mm IP65 VPT02A0-6PT2 Stainless steel Stainless steel * The exact value is indicated on the instrument nameplate. MECHANICAL DIMENSIONS ø A ø B ø C D ø E I ø J ø K Wires nr. Nm* N 2 HOLES EQUIDISTANTS VPT02A0-6PT2 CONNECTOR Ln (kn) M8x,5 98 6,5 8xM6 20 PREFERENTIAL LOAD INTRODUCTION DIRECTION FOR POSITIVE OUTPUT N 8 HOLES EQUIDISTANTS M30x2 30 2xM0 90 Dimensions mm. (± 0,) * Recommended torque with UNI 593 screws of resistance class 0.9 according to UNI 3740.

18 ELECTRICAL CONNECTIONS OPTIONAL ACCESSORIES CONNECTOR OUTPUT CABLE OUTPUT Female cable connector Grade of protection IP65 CON EXCITATION + EXCITATION - CALIBRATION SHUNT Black Blue-Orange 6-pin connector with 8m (25ft) cable 6-pin connector with 5m (50ft) cable 6-pin connector with 25m (75ft) cable 6-pin connector with 30m (00ft) cable C08W C5W C25W C30W Other lengths consult factory ORDER CODE VPT02A0-6PT2 CONNECTOR Force transducer TH If the transducer is supplied complete with prewired connection cable, the colour code is that indicated in the table. Cells connected in parallel Yellow- MEASUREMENT RANGE (kn) KND KN2D 0-30 KN3D 0-50 KN5D 0-00 KNC If request, it is possible to supply models with non-standard mechanical and/or electrical features. Yellow- Yellow- Es.: TH - KN5D TH force transducer, with measurement range 0-50 kn. SHUNT BOX In systems that use several cells, the parallel connection automatically sums the loads on each individual cell. Using this method of measurement, the maximum load will be the sum of the loads on the individual cells and the sensitivity will be the average value of these cells. It is important that the user ensures that no cell is stessed beyond its maximum rating under any load condition. CONVERSION TABLE Kg N Lb GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice. GEFRAN spa via Sebina, PROVAGLIO D ISEO (BS) - ITALIA ph fax Internet: cod. TH -09/04

19 CC (B - C) CYLINDRICAL FORCE TRANSDUCER FOR INDUSTRIAL APPLICATIONS Main features Range of measurement: from 750 to.500 kn Accuracy class: 0,5% Internally generated calibration signal All stainless steel construction Corrosion resistant Grade of protection: IP65 ( norme DIN 40050) The CC force transducers have been designed for use in the plastics industry where it is required to measure the reaction force to the extrusion pressure that is present on the casing of the gearbox along the axis of the extruder screw. These models, fitted in contact with the thrust bearings, measure a force whose valve, after suitable correction, is equal to extrusion pressure multiplied by the screw area. The CC cylindrical force transducers are all stainless steel construction and configured in such a way that the body, airtight welded, acts also as the case, making a unit that is smaller than the CT series. The connector in the shank is on the same axis as the transducer, which in some cases alows easier installation. TECHNICAL DATA Accuracy Nominal full scale load (Ln) 0,5% kn MECHANICAL DIMENSIONS Nominal output at FSO 2mV/V Output tolerance at Ln <± % FSO Combined errors: Non linearity Histeresis, Repeatibility < ± 0,5% FSO Creep (after 30 min. at Ln) < ± 0,06% FSO Zero load out of balance signal < ± % FSO Calibration signal * 80%FSO ± % Thermal drift in compensated range Sensitivity Zero Calibration < ± 0,02% FSO C < ± 0,02% FSO C < ± 0,02% FSO C Nominal input resistance 700 Ohm Isolation resistance > 0 GOhm Nominal supply voltage 0 V Maximum supply voltage 5 V Compensated temperature range C Maximum temperature range C Storage temperature range C Permitted static load 30% Ln Maximum applicable load 50% Ln Rupture load > 300% Ln Carico statico laterale max. 40% Ln Maximum elastic deformation at Ln < 0, mm Grade of protection (DIN40050) IP65 Electr. connections: Connector Elastic element material Case material VPT02A0-6PT2 Stainless steel Stainless steel * The exact value is indicated on the instrument nameplate. mod. CCB CCC Dimensions mm. (± 0,) Ln (kn) øa øb C D 03 03

20 ELECTRICAL CONNECTIONS OPTIONAL ACCESSORIES + - CONNECTOR OUTPUT CABLE OUTPUT Black Connectors Female cable connector Grade of protection IP65 CON 300 EXCITATION + VPT02A0-6PT2 CONNECTOR EXCITATION - CALIBRATION SHUNT Cells connected in parallel Blue-Orange If the transducer is supplied complete with prewired connection cable, the colour code is that indicated in the table. 6-pin connector with 8m (25ft) cable 6-pin connector with 5m (50ft) cable 6-pin connector with 25m (75ft) cable 6-pin connector with 30m (00ft) cable Other lengths APPLICATION NOTES C08W C5W C25W W30W consult factory For a correct use of the transducer, it is necessary to ensure that the load is evenly distributed over the application surfaces shown in the diagram. It is essential to centre the transducer using the circular crow of diameter A and to apply the load installing the transducer between two grinded surfaces perpendicular to the direction of the applied load. Yellow- Yellow- ORDER CODE SHUNT BOX In systems that use several cells, the parallel connection automatically sums the loads on each individual cell. Using this method of measurement, the maximum load will be the sum of the loads on the individual cells and the sensitivity will be the average value of these cells. It is important that the user ensures that no cell is stessed beyond its maximum rating under any load condition. Force transducer MODEL B C CC Mod. MEASUR. RANGE (kn) CCB KN7.5C CCC KN.5M CONVERSION TABLE If request, it is possible to supply models with non-standard mechanical and/or electrical features. Kg N Lb Ex.: CCB - KN7,5C CC force transducer, model B, measurement range kn. GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice. GEFRAN spa via Sebina, PROVAGLIO D ISEO (BS) - ITALIA ph fax Internet: cod. CC - 09/04

21 CT ( A - B - C - D) TOROIDAL FORCE TRANSDUCER FOR INDUSTRIAL APPLICATIONS Main features Range of measurement: from 00 to 3000 kn Accuracy class: 0,5% Elastic element in stainless steel Corrosion resistant Internally generated calibration signal Grade of protection: IP65 (DIN 40050) The CT series force transducers, have been specially designed for use in polymer processing in applications where it is required to measure the reaction force produced by the extrusion pressure on the gearbox along the axis of the screw. They measure a force whose value is indicative of the extrusion pressure over the area of the screw. The CT series force transducers can also be used in all other applications where it is required to measure the forces on shafts or columns and in any application where the geometry demands a toroidal form load cell. TECHNICAL DATA Accuracy 0,5% Nominal full scale load (Ln) Nominal output at FSO kn 2mV/V MECHANICAL DIMENSIONS Output tolerance at Ln Combined errors: Non linearity Histeresis, Repeatibility <± % FSO < ± 0,5% FSO Load introduction direction Creep (after 30 min. at Ln) < ± 0,06% FSO Zero load out of balance signal < ± % FSO Calibration signal * 80%FSO ± % Thermal drift in compensated range Sensitivity Zero Calibration < ± 0,02% FSO C < ± 0,02% FSO C < ± 0,02% FSO C Load introduction surface Nominal input resistance 700 Ohm Isolation resistance > 0 GOhm Nominal supply voltage 0 V Maximum supply voltage 5 V Compensated temperature range C Maximum temperature range C Storage temperature range C Dimensions mm. (± 0,) Permitted static load Maximum applicable load Rupture load Maximum static lateral load Maximum elastic deformation at Ln Grade of protection (DIN40050) Electr. connections: Connector Elastic element material Case material 30% Ln 50% Ln > 300% Ln 40% Ln < 0, mm IP65 VPT02A0-6PT2 Stainless steel Anodize aluminium * The exact value is indicated on the instrument nameplate. mod. CTA CTB CTC CTD Ln (kn) A B 54,2 52,6 50,7 76,2 74,9 72, ,8 00,2 97,9 95,3 24, 20, 5,8,4 C 57,8 59,7 6,4 8,3 82,5 84,9 84,7 2, 4,2 6,5 8,6 46,2 49,6 52,9 56 D E F

22 ELECTRICAL CONNECTIONS OPTIONAL ACCESSORIES Connectors + CONNECTOR OUTPUT CABLE OUTPUT Female cable connector Grade of protection IP65 CON300 - EXCITATION + EXCITATION - CALIBRATION SHUNT Black Blue-Orange 6-pin connector with 8m (25ft) cable 6-pin connector with 5m (50ft) cable 6-pin connector with 25m (75ft) cable 6-pin connector with 30m (00ft) cable C08W C5W C25W C30W Other lengths consult factory APPLICATION NOTE CONNECTOR VPT02A0-6PT2 If the transducer is supplied complete with prewired connection cable, the colour code is that indicated in the table. Cells connected in parallel For a correct use of the transducer, it is necessary to ensure that the load is evenly distributed over the application surfaces shown in the diagram. It is essential to centre the transducer using the circular crown of diameter C and to apply the load installing the transducer between two grinded surfaces perpendicular to the direction of the applied load. ORDER CODE Yellow- Force transducer CT Yellow- Yellow- MODEL A B C D CONVERSION TABLE SHUNT BOX In systems that use several cells, the parallel connection automatically sums the loads on each individual cell. Using this method of measurement, the maximum load will be the sum of the loads on the individual cells and the sensitivity will be the average value of these cells. It is important that the user ensures that no cell is stessed beyond its maximum rating under any load condition. Mod. CTA CTB CTC CTD MEASUR. RANGE (kn) KNC KN2C KN3C KN2C KN3C KN5C KN7.5C KN5C KN7,5C KNM KN.5M KN.5M KN2M KN2.5M KN3M Kg N Lb If request, it is possible to supply models with non-standard mechanical and/or electrical features Ex.: CTC - KNM CT force transducer, model C, measurement range kn. GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice. GEFRAN spa via Sebina, PROVAGLIO D ISEO (BS) - ITALIA ph fax Internet: cod. CT - 09/04

23 SB LOW PROFILE SHEAR LOAD CELL Main features Range of measurement: from 500 to Kg Accuracy class: D (OIML R60) All stainless steel construction Corrosion resistant Insensitive to lateral loads Low profile Class of protection: IP66 (DIN 40050) The principle of measurement of the SB series of load cells is the deformation caused by the shear generated by the applied load. They are compact load cells with an all stainless steel construction that are extremely rigid towards the measured load and lateral or transverse loads. The SB series load cells are the ideal solution for industrial weighing applications such as storage silos, weighing platforms and dosing systems. TECHNICAL DATA MECHANICAL DIMENSIONS Accuracy (OIML IR60) D Hole version Divisions 000 Shrinked cable Nominal full scale load (Ln) Kg Nominal full scale output FSO 3mV/V Output tolerance at Ln Combined errors*: Non linearity Histeresis, Repeatibility <± 0,2% FSO < ± 0,03% FSO Screened cable Q (support quota) Creep (after 30 min. at Ln) < ± 0,03% FSO Zero load out of balance signal < ± 0,5% FSO Thermal drift in compensated range * Sensitivity Zero Calibration < ± 0,005% FSO C < ± 0,0% FSO C - Thread hole version Shrinked cable Nominal input resistance 350 Ohm Nominal output resistance 350 Ohm Isolation resistance > 0 GOhm Q (support quota) Nominal supply voltage 0 V Screened cable Maximum supply voltage 5 V Compensated temperature range C Maximum temperature range Storage temperature range Permitted static load Maximum applicable load Rupture load Maximum elastic deformation at Ln Grade of protection (DIN40050) Electr. connections screened cable Elastic element material C C 30% Ln 50% Ln > 300% Ln < 0,6 mm IP66 4x0,25 / 5 m. Stainless steel ø A ø B M H S L L L2 L3 Z Nm* Q Ln (Kg) 500/000/2000 3,4 3,4 M2 3,75 3, ,75 25,4 76, ,5 20,5 M8x,5 47,6 38 7,5 9, 38, 95,3, * The combined error and sensitivity thermal drift as a whole are within the limits defined by the OIML IR60 Dimensions mm. (± 0,) * Recommended torque with UNI 593 screws of resistance class 0.9 according to UNI 3740

24 ELECTRICAL CONNECTIONS OPTIONAL ACCESSORIES CABLE EXIT EXCITATION EXCITATION Shield SHIELD 4x0.25 Screened cable Yellow- ORDER CODE Load cell SB Cells connected in parallel Yellow- Yellow- Yellow * The screen is isolated from the transducer body. It is recommended that the ground is connected at the instrument end. Yellow- MEASUREMENT RANGE (Kg) K5C KM K2M K5M LOAD APPLICATION HOLE Hole version * Thread hole version FP FF * not available for Kg version If request, it is possible to supply models with non-standard mechanical and/or electrical features. Ex.: SB - KM - FP SB load cell, measurement range kg. Load application hole without thread. Ex2.: SB - KM - FF SB load cell, measurement range kg. Load application hole with thread SHUNT BOX In systems that use several cells, the parallel connection automatically sums the loads on each individual cell. Using this method of measurement, the maximum load will be the sum of the loads on the individual cells and the sensitivity will be the average value of these cells. It is important that the user ensures that no cell is stessed beyond its maximum rating under any load condition. CONVERSION TABLE Kg N Lb GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice. GEFRAN spa via Sebina, PROVAGLIO D ISEO (BS) - ITALIA ph fax Internet: cod. SB - 09/04

25 SH SHEAR TYPE LOAD CELL Main features Range of measurement: from 500 to Kg Accuracy class: D (OIML R60) All stainless steel construction Corrosion resistant Insensitive to lateral loads Grade of protection: IP66 ( DIN 40050) The principle of measurement of the SH series load cells is the deformation caused by the shear generated by the applied load. The result is a transducer that is extremely rigid both for the measured load and of lateral or transverse loads which have little effect on it. The high degree of accuracy, good level of thermal compensation, the grade of protection make the SH series load cells safe for use in the most severe conditions. TECHNICAL DATA Accuracy (OIML IR60) Divisions Nominal full scale load (Ln) Nominal output at FSO Output tolerance at Ln Combined errors: Non linearity Histeresis, Repeatibility Creep (after 30 min. at Ln) Zero load out of balance signal Calibration signal * Thermal drift in compensated range Nominal input resistance Nominal output resistance Isolation resistance Nominal supply voltage Maximum supply voltage Sensitivity Zero Calibration Compensated temperature range Maximum temperature range Storage temperature range Permitted static load Maximum applicable load Rupture load Maximum elastic deformation at Ln Grade of protection (DIN40050) Electr. connections screened cable Elastic element material D Kg 2mV/V <± 0,2% FSO < ± 0,05% FSO < ± 0,05% FSO < ± % FSO 80%FSO ± % < ± 0,005% FSO/ C < ± 0,0% FSO/ C Ohm 350 Ohm > 0 GOhm 0 V 5 V C C C 30% Ln 50% Ln > 300% Ln < 0,7 mm IP66 4x0,25 / 5 m. Stainless steel * The combined errors and thermal drift of sensitivity are within the framework defined by the OIML IR60 MECHANICAL DIMENSIONS ø A ø B ø C H H0 H L L0 L L2 L3 S T Z Nm* 500/000/ ,2 7,5 3,2 47,6 36,5,9 203, ,3 63,5 9, 36,5 23,8 0,25 35 Ln (Kg) 5000/7500 4,3 25,5 22, ,8 5, ,7 66,5 20,6 47, Screened cable Shrinked cable ,6 63,5 20,7 279, ,7 82,6 25,4 60, Dimensions mm. (± 0,) Recommended torque with UNI 593 screws of resistance class 0.9 according to UNI 3740

26 ELECTRICAL CONNECTIONS OPTIONAL ACCESSORIES CABLE EXIT EXCITATION EXCITATION Shield SHIELD 4x0.25 Screened cable Yellow- ORDER CODE Load cell SH Cells connected in parallel * The screen is isolated from the transducer body. It is recommended that the ground is connected at the instrument end. Yellow MEASUREMENT RANGE (Kg) K5C KM K2M K5M K7.5M K0M If request, it is possible to supply models with non-standard mechanical and/or electrical features. Yellow- Ex.: SH - K0M SH load cell, measurement range kg. Yellow- Yellow- SHUNT BOX In systems that use several cells, the parallel connection automatically sums the loads on each individual cell. Using this method of measurement, the maximum load will be the sum of the loads on the individual cells and the sensitivity will be the average value of these cells. It is important that the user ensures that no cell is stessed beyond its maximum rating under any load condition. CONVERSION TABLE Kg N Lb GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice. GEFRAN spa via Sebina, PROVAGLIO D ISEO (BS) - ITALIA ph fax Internet: cod. SH - 09/04

27 CB DEFLECTION LOAD CELL Main features Range of measurement: from 20 to 200 Kg Accuracy class: C (OIML R60) All stainless steel construction Corrosion resistant Grade of protection: IP67 ( DIN 40050) CB series load cells are designed for trouble free application in industrial environments. The cell body and the protective bellows of the strain gauge are in corrosion resistant stainless steel and the bellows are welded using microplasma torch. CB load cells are supplied in three grades of accuracy and characteristics. The 000 division is the most economical and suitable for most applications. The 2000 division version has a good price/performance ratio. The 3000 division is available if higher accuracy is required. CB load cells are used in particularly hostile enviroments in the food, petrochemical and pharmaceutical industries and in all applications that demand components in stainless steel and IP67 grade of protection. TECHNICAL DATA Accuracy (OIML IR60) Divisions Nominal full scale load (Ln) Nominal output at FSO Output tolerance at Ln (%FSO) Combined errors: Non linearity Histeresis, Repeatibility Creep (after 30 min. at Ln)%FSO Zero load out of balance signal Thermal drift in compensated range * %FSO C Nominal input resistance Nominal output resistance Isolation resistance Nominal supply voltage Maximum supply voltage Sensitivity Zero Calibration Compensated temperature range Maximum temperature range Storage temperature range Permitted static load Maximum applicable load Rupture load Maximum elastic deformation at Ln Grade of protection (DIN40050) Electr. connections screened cable Elastic element material C C2 C kg 2 mv/v < ± 0,5 < ± 0,5 < ± 0,2 C C2/C3 < ± 0,05 % FSO < ± 0,03 % FSO < ± 0,05 < ± 0,025 < ± 0,07 < ± % FSO < ± 0,003 < ± 0,005 < ± 0,005 < ± 0,009 < ± 0,006 < ± 0, Ohm 350 Ohm > 0 GOhm 0 V 5 V C C C 30% Ln 50% Ln >300% Ln < 0,5 mm IP67 4x0,25 5m. Stainless steel * The combined errors and thermal drift of sensitivity are within the framework defined by the OIML IR60 MECHANICAL DIMENSIONS SCREENED CABLE ø27 R3 ø8.2 ø8.2 ø8.2 Dimensions mm. (± 0,) Recommended torque with UNI 593 screws of resistance class 0.9 according to UNI Nm LOAD INTRODUCTION DIRECTION R ø30 ø42

28 ELECTRICAL CONNECTIONS OPTIONAL ACCESSORIES CABLE EXIT EXCITATION EXCITATION SHIELD Yellow Blue Yellow/ 4x0.25 Screened cable Shield ORDER CODE Load cell CB Cells connected in parallel Yellow * The screen is isolated from the transducer body. It is recommended that the ground is connected at the instrument end. MEASUREMENT RANGE (Kg) K2D K5D 0-00 KC K2C ACCURACY CLASS OIML C 000 divisions C divisions C divisions C C2 C3 Yellow- If request, it is possible to supply models with non-standard mechanical and/or electrical features. Yellow- Yellow- Ex.: CB - KC - C2 CB load cell, measurement range 0-00 kg., accuracy class C2/2000 divisions. SHUNT BOX In systems that use several cells, the parallel connection automatically sums the loads on each individual cell. Using this method of measurement, the maximum load will be the sum of the loads on the individual cells and the sensitivity will be the average value of these cells. It is important that the user ensures that no cell is stessed beyond its maximum rating under any load condition. CONVERSION TABLE Kg N Lb GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice. GEFRAN spa via Sebina, PROVAGLIO D ISEO (BS) - ITALIA ph fax Internet: cod. CB - 09/04

29 OC LOW PROFILE LOAD CELL FOR PLATFORMS Main features Range of measurement: from 5 to 00 kg Accuracy class: C (OIML R60) May be mounted directly on the weighing platform Humidity resistant: conform to OIML R60 Low cost Applicable Platform: 400 x 400 mm Certified by NMI Institute according to: OIML R60 Certificate nr. TC2330 The OC series load cells have been designed for all applications requiring accurate weighing of loads on a platform, as well as for general applications in conformity with the OIML standards. In all these cases, the OC load cell is the heart of the mechanical design. Infact they provide automatic compensation for eccentric loads on platforms up to 400x400mm without the need of mechanical calibrations. The OC series low profile load cells are used in weighing machines for piece counting, bottling, dosing, weighing parcels, fiscal weighing, pharmaceutical weighing, etc. TECHNICAL DATA Accuracy (OIML IR60) Divisions Nominal full scale load (Ln) Nominal full scale output FSO Output tolerance at Ln Combined error * (Linearity,Histeresis, Repetibility) Creep (after 30 min. at Ln) %FSO Zero load out of balance signal Thermal drift in compensated * range %FSO C Sensitivity Zero Calibration Error for eccentric load (with /3 Ln) on 400 x 400 platform (%FSO) Nominal input resistance Nominal output resistance Isolation resistance Nominal supply voltage Maximum supply voltage Compensated temperature range Maximum temperature range Storage temperature range Permitted static load Maximum applicable load Maximum elastic deformation at Ln Protection / Case Electr. connections: screened cable Elastic element material C C2 C C C2/C kg 2 mv/v < ± 0% FSO < ± 0,05 % FSO < ± 0,03 % FSO < ± 0,05 < ± 0,025 < ± 0,07 < ± 0% FSO < ± 0,003 < ± 0,005 < ± 0,005 < ± 0,009 < ± 0,006 < ± 0,004 - < ± 0,05 < ± 0,03 < ± 0, Ohm 350 Ohm > 0 GOhm 0 V 5 V C C C 00% Ln 50% Ln < 0,5 mm Silicon / Nylon 66 G20 W0 4x0,25 m. Aluminium * The combined errors and thermal drift of sensitivity are within the framework defined by the OIML IR60 MECHANICAL DIMENSIONS Screened cable * 7 M6 HOLES WITH THREAD DEPTH OF 0 mm ** SEAT FOR SHEAR PIN Dimensions mm. (± 0,) Recommended torque for M6 fixing screws: 7Nm

30 ELECTRICAL CONNECTIONS OPTIONAL ACCESSORIES EXCITATION EXCITATION SHIELD CABLE EXIT Yellow- APPLICATION NOTES PLATFORM CENTRE 4x0.25 Screened cable Shield Example of a load cell for a platform with overload end stops fitted under the corners and on the load cell itself. Yellow * The screen is isolated from the transducer body. It is recommended that the ground is connected at the instrument end. ORDER CODE Load cell OC CONVERSION TABLE Kg N Lb MEASUREMENT RANGE (kg) 0-5 K5U K7.5U 0-0 KD 0-20 K2D 0-35 K3.5D 0-50 K5D 0-75 K7.5D 0-00 KC CLASS OF ACCURACY OIML C 000 divisions C C divisions C2 C divisions C3 If request, it is possible to supply models with non-standard mechanical and/or electrical features. Ex.: OC - KD - C2 OC load cell, measurement range 0-0 kg, accuracy class C2/2000 divisions. GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice. GEFRAN spa via Sebina, PROVAGLIO D ISEO (BS) - ITALIA ph fax Internet: cod. OC - 09/04

31 OD LOAD CELL FOR PACKAGING AND DOSING APPLICATIONS Main features Range of measurement: kg Accuracy class: C (OIML R60) May be mounted directly on the weighing platform Applicable Platform : 400x400 mm. Grade of protection: conform to humidity test OIML R60 Certified by NMI Institute according to: OIML R60 Certificate nr. TC2772 The OD series load cells have been designed for all applications requiring accurate weighing of loads on a platform, as well as for general applications in conformity with the OIML standards. In all these cases, the OD load cell is the heart of the mechanical design. Infact they provide automatic compensation for eccentric loads on platforms up to 400x400mm without the need of mechanical calibrations and have mechanical stops which allow the installation without particular adjustments. The OD series low profile load cells are used in weighing machines for piece counting, bottling, dosing, weighing parcels, fiscal weighing, pharmaceutical weighing, etc. TECHNICAL DATA Accuracy (OIML IR60) Divisions Nominal full scale load (Ln) Nominal full scale output FSO Output tolerance at Ln Combined errors * (Linearity, Histeresis, Repeatibility) Creep (after 30 min. at Ln)%FSO Zero load out of balance signal Thermal drift in compensated * range %FSO C Sensitivity Zero Calibration Error for eccentric load (with /3 Ln) on 400 x 400 platform (%FSO) Nominal input resistance Nominal output resistance Isolation resistance Nominal supply voltage Maximum supply voltage Compensated temperature range Maximum temperature range Storage temperature range Permitted static load Maximum applicable load Rupture load Maximum elastic deformation at Ln Protection Electr. connections: screened cable Elastic element material C C2 C C C2/C kg 2 mv/v < ± 0% FSO < ± 0,05 % FSO < ± 0,03 % FSO < ± 0,05 < ± 0,025 < ± 0,07 < ± 0% FSO < ± 0,003 < ± 0,005 < ± 0,005 < ± 0,009 < ± 0,006 < ± 0,004 - < ± 0,05 < ± 0,03 < ± 0, Ohm 350 Ohm > 0 GOhm 0 V 5 V C C C 00% Ln 50% Ln >300% Ln < 0,3 mm Silicon, case nylon 66G20W0 4x0,25 / m. Aluminium * The combined errors and thermal drift of sensitivity are within the framework defined by the OIML IR60 MECHANICAL DIMENSIONS VIEW A LOAD side Dimensions mm. (± 0,) Recommended torque for fixing screws 7 Nm VIEW B FIXING side

32 ELECTRICAL CONNECTIONS OPTIONAL ACCESSORIES CABLE EXIT EXCITATION EXCITATION SHIELD Yellow- 4x0.25 Screened cable Shield APPLICATION NOTES Yellow * The screen is isolated from the transducer body. It is recommended that the ground is connected at the instrument end. CELL CONVERSION TABLE Kg N Lb CELL ORDER CODE Load cell OD MEASUREMENT RANGE (Kg) K6U KD 0-5 K,5D CLASS OF ACCURACY OIML C 000 divisions C divisions C divisions C C2 C3 If request, it is possible to supply models with non-standard mechanical and/or electrical features. Ex.: OD - KD - C2 OD load cell, measurement range 0-0 kg. Clas of accuracy C2/2000 divisions. GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice. GEFRAN spa via Sebina, PROVAGLIO D ISEO (BS) - ITALIA ph fax Internet: cod. OD - 09/04

33 CIR STRAIN GAUGE TRANSDUCER AMPLIFIER Main features Linearity error <0,02%FSO Voltage or current output Low thermal drift <0,0%FSO/ C Compact size The CIR voltage or current amplifiers have been designed to enable the user to adapt non-amplified strain gauge transducers (load cells, pressure transducers) to acquisition systems, PLC, instrumentation with high level inputs. The availability of the output in voltage or current enables the signal to be carried over long distances or used in intelligent automation systems. TECHNICAL DATA Model Linearity error (FSO) Primary sensor resistance (± 0%) Primary sensor sensitivity Output load resistance Supply voltage Current drain with sensor connected Supply voltage to transducer Output signal at zero Zero signal accuracy (FSO) Zero adjustment (FSO) Full scale output F.S. output accuracy Span adjustment Inverse polarity protection Accidental shortcircuit protection Response time (0...90%FSO) Output noise (RMS Hz) Temp. range: (%FSO) Compensated Working Storage Typical thermal drift of zero (%FSO/ C) Typical thermal drift of span (%FSO/ C) Length of output cable Case material Grade of protection Voltage B/C/M/N < or or 3 > < 33 The electrical characteristics are those measured with Vsupply.=24VRL = MΩ (Voltage) RL = 500 Ω (Current) Amb.temp = 25 C 0 B/C = 0,Vdc M/N = 0Vdc < ± 0, > ± 0 B = 5,Vdc C = 0,Vdc M = 5Vdc N = 0Vdc < ± 0, > ± 0 YES YES ± 0,0 ± 0,0 Current E < or or 3 see diag ,9 E = 4mA < ± 0, > ± 0 E = 20mA < ± 0, > ± 0 YES YES ± 0,0 ± 0,0 Stainless steel / Anodisez alum. IP65 IP65 EN meas. unit % Ω mv/v KΩ Vdc ma Vdc % % % % ms db C C C mt MECHANICAL DIMENSIONS INPUT (to Cell) SCREENED CABLE Length = metre Shield OUTPUT Yellow- Blue (*) Orange (*) * Only for version Z

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS MELT PRESSURE TRANSMITTERS I3 SERIES mv/v Output D The IMPACT series of Gefran, are pressure transmitters, without transmission fluid, for using in High temperature environment (350 C). Medium pressure

More information

K3D60a ±100N. Description. The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes.

K3D60a ±100N. Description. The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes. K3D60a ±100N Description The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes. The new 3-axis sensor K3D60a is a further development of the series K3D60 and

More information

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN TECHNICAL DATA TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN Main features Ranges: from 0...10 to 0...1000 bar Output signal 4...0mA -wires / 0.1...5.1Vdc / 0.1...10.1Vdc / 0...5Vdc

More information

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10 Compression force transducer with Thin-film sensor Accuracy: 1 % Output signal: 4...20 ma; 2-wire, 0...10 VDC; 3-wire Optional Optional ATEX/IECEX II 2G Ex ib IIC T4/T3 for SIL3-Applications with 2-channel

More information

Force and weight measuring instruments

Force and weight measuring instruments JJ Force sensors and load cells JJ Measurement amplifiers JJ Mechanical and electronic accessories JJ Combination units JJ Force calibration systems Force and weight measuring instruments DS_Force_and_weight_measuring_instruments

More information

SRS SEALED ROTARY SENSORS

SRS SEALED ROTARY SENSORS SRS SEALED ROTARY SENSORS Innovation In Motion INNOVATION IN MOTION Penny+Giles SRS280 sealed rotary sensors and SRS880 submersible rotary sensors have been specially developed to provide maximum performance

More information

Type PB Load Cell. Approvals OIML approval to C3 (Y = 7 500; Y = for 375 kg capacity)

Type PB Load Cell. Approvals OIML approval to C3 (Y = 7 500; Y = for 375 kg capacity) Type PB Load Cell IP65 Product Description The type PB is a very low profile planar beam load cell. Its unique Flintec design allows for an extremely low scale construction. Using 3 or 4 type PB load cells

More information

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch]

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch] U10M Force Transducer Special features - Precise and robust tensile/compressive force transducer for static and dynamic measurement tasks - High lateral force and bending moment stability, the effect of

More information

Shear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1

Shear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1 Force Shear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1 Rated force From 0...2 kn Applications Industrial weighing technology Machine building and plant construction, manufacturing

More information

Load Cells Shear beam load cells SIWAREX WL230 SB-S SA

Load Cells Shear beam load cells SIWAREX WL230 SB-S SA oad cell Overview Combined error comb Repeatability v ±0.0% C n ±0.0% C n The shear beam load cell is particularly suitable for implementation in container, overhead rail conveyor and platform scales.

More information

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications. Force Tension/compression force transducer With thin film technology up to 100 kn Models F2301, F23C1, F23S1 tecsis data sheet FO 51.17 Applications Crane systems and hoists Industrial weighing technology

More information

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications. Force Tension/compression force transducer With thin film technology up to 100 kn Models F2301, F23C1, F23S1 WIKA data sheet FO 51.17 Applications Crane systems and hoists Industrial weighing technology

More information

Model 3A Series 3-Axis Load Cell

Model 3A Series 3-Axis Load Cell Model 3A Series 3-Axis Load Cell 3-Axis Fx Fy Fz; Independent Bridges 20N to 500kN Force Range Compact Size Low Crosstalk Temperature Compensated Accessories Model 3A60A BSC4A 4-Channel Analog Amplifier

More information

Model 3A Series 3-Axis Load Cell

Model 3A Series 3-Axis Load Cell Model 3A Series 3-Axis Load Cell 3-Axis Fx Fy Fz; Independent Bridges 20N to 500kN Force Range Compact Size Low Crosstalk Temperature Compensated Accessories BSC4A 4-Channel Analog Amplifier BSC4D 4-Channel

More information

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS2000S Hermetically sealed bending beam load cell

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS2000S Hermetically sealed bending beam load cell BB ME SURE ME NT & N L YT ICS D T SHE ET 9QGPS2000S Hermetically sealed bending beam load cell 2 Measurement made easy High-end load cell combining high accuracy with high resistance in harsh environment.

More information

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES Precision Low Profile Load Cell DESCRIPTION Model 41E is a low profile pancake type load cells. These bonded foil, strain gage load cells are engineered to measure loads from 20 N to 200 kn. The tension/

More information

Catalog of CLA force and torque sensors

Catalog of CLA force and torque sensors Catalog of CLA force and torque sensors SC-002 LC-01 LC-10 TSF-000 TSF-05 TSF-1 TSF-100 Micro-force sensor Force sensor Micro-torque sensor Torque sensor Phone +41 32 421 44 90, Fax +41 32 421 44 91, ventes@cla.ch,

More information

SPIETH Locknuts. Series MSW. Works Standard SN 04.03

SPIETH Locknuts. Series MSW. Works Standard SN 04.03 SPIETH Locknuts Series MSW Works Standard SN 0.03 SPIETH Locknuts Series MSW SPIETH locknuts offer a range of technical benefits, qualified by their special system and production. Under high levels of

More information

K3R110 ±50N; ±100N, ±200N; ±500N, ±1000N, ±2000N; ±5000N

K3R110 ±50N; ±100N, ±200N; ±500N, ±1000N, ±2000N; ±5000N K3R110 ±50N; ±100N, ±200N; Description The force sensor K3R110 is suitable for inspection tasks in quality assurance as well as in materials testing because of its compact design. This precision force

More information

C10. Data sheet. Force transducer. Special features. B de

C10. Data sheet. Force transducer. Special features. B de C10 Force transducer Data sheet Special features Force transducer for static and dynamic applications Made of non-rusting materials Precise (accuracy class from 0.03) Numerous options (double bridge, TEDS,

More information

LB-LE-LU SERIES USER GUIDE LOAD MEASURING PINS.

LB-LE-LU SERIES USER GUIDE LOAD MEASURING PINS. LB-LE-LU SERIES LOAD MEASURING PINS USER GUIDE 01 LB-LE-LU series While every precaution has been exercised in the compilation of this document to ensure the accuracy of its contents, Magtrol assumes no

More information

General Specification

General Specification 2001 Catalog General Specification WISE SENSOR INC. WISE SENSOR INC. C O N T E N T S Product guide for pressure measurement Product guide for level measurement Product guide for temperature measurement

More information

LOAD MEASURING PINS LE-LU SERIES FEATURES DESCRIPTION APPLICATIONS

LOAD MEASURING PINS LE-LU SERIES FEATURES DESCRIPTION APPLICATIONS LE-LU SERIES LOAD MEASURING PINS Magtrol offers a wide range of Load-Force-Weight Transducers with optional integrated electronics or Load Monitoring Units (LMU) with B.I.T.E. functions creating an ideal

More information

Model LBS Miniature Compression Load Button

Model LBS Miniature Compression Load Button Model LBS Miniature Compression Load Button Why the Interface model LBS Miniature Compression Load Button is the best in class: Temperature compensated Integral load button Small diameter From." height

More information

Bestech Australia U14/44 Garden Blvd, Tel: Dinely VIC 3172 Fax:

Bestech Australia U14/44 Garden Blvd, Tel: Dinely VIC 3172 Fax: Load cell 50... 500 kg High capacity single point load cell made of aluminum. EEC approvals in 3000 d according to OIML R60 and up to 5000 d NTEP. Designed to fit with single point platforms of maximum

More information

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants U15 Force transducer Special features - Tensile/compressive force transducer - Nominal (rated) forces 2.5 kn to 2.5 MN - lass 0.5 to ISO 376 in force measurement range between 10% and 100% of the nominal

More information

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax: Load Cell F60X Bending beam load cell made of stainless steel, hermetically sealed. Approved up to 6000d R60 OIML. Level of protection IP 68. ATEX 94/9/CE version for hazardous area (option). Designed

More information

Torque Sensor Series 3000 and Series 4000

Torque Sensor Series 3000 and Series 4000 Properties Sensorshaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement range

More information

U2B. Data sheet. Force Transducer. Special features. B en

U2B. Data sheet. Force Transducer. Special features. B en U2B Force Transducer Special features Data sheet Tensile/compressive force transducer Non-rusting, degree of protection IP67 Can be configured with different cable lengths, plug fitting and TEDS on request

More information

Rotary Measurement Technology Incremental Encoders

Rotary Measurement Technology Incremental Encoders -20 to 60 C Temperature Shock/vibration resistant Short-circuit protection Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection

More information

Load Cell Accessories and Services

Load Cell Accessories and Services Load Cell Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Mounting accessories Calibration services PCB Piezotronics, Inc. Toll-Free in USA 888-684-0004 716-684-0001

More information

Load Cells LOAD CELLS

Load Cells LOAD CELLS Load Cells Honeywell manufactures a wide range of tension, compression, and universal measurement load cells. Our load cells are industrially rugged and feature enhanced reliability due to stainless steel

More information

SUMMARY. V-Lock SYSTEM BASIC ELEMENTS ACTUATORS. P V-Lock GENERAL INTRODUCTION 2. P V-Lock FIXING ELEMENTS 10 SUMMARY. P V-Lock ADAPTORS 17

SUMMARY. V-Lock SYSTEM BASIC ELEMENTS ACTUATORS. P V-Lock GENERAL INTRODUCTION 2. P V-Lock FIXING ELEMENTS 10 SUMMARY. P V-Lock ADAPTORS 17 SUMMARY A3 V-Lock SYSTEM P V-Lock GENERAL INTRODUCTION 2 BASIC ELEMENTS P V-Lock FIXING ELEMENTS 10 P V-Lock ADAPTORS 17 SUMMARY P PROFILES 28 P V-Lock ACCESSORIES AND SPARE PARTS 32 1 A3 GENERAL INTRODUCTION

More information

U2B. Force Transducer. Special features. Data sheet

U2B. Force Transducer. Special features. Data sheet U2B Force Transducer Special features - Tensile/compressive force transducer - Non rusting, degree of protection IP67 - Can be configured with different cable lengths, plug fitting and TEDS on request

More information

1. Enumerate the most commonly used engineering materials and state some important properties and their engineering applications.

1. Enumerate the most commonly used engineering materials and state some important properties and their engineering applications. Code No: R05310305 Set No. 1 III B.Tech I Semester Regular Examinations, November 2008 DESIGN OF MACHINE MEMBERS-I ( Common to Mechanical Engineering and Production Engineering) Time: 3 hours Max Marks:

More information

Electronic Temperature Transmitters

Electronic Temperature Transmitters Electronic Temperature Transmitters ELECTRONIC TEMPERATURE TRANSMITTERS As with the pressure transmitters, HYDAC ELECTRONIC also has temperature transmitters appropriate for every application. The transmitters

More information

ENCODER. Analog Multiturn Encoder. Serie 8.M3661/M3681. Key-Features:

ENCODER. Analog Multiturn Encoder. Serie 8.M3661/M3681. Key-Features: ENCODER Multiturn Encoder Serie 8.M366/M368 Key-Features: Content: Order Code...2 Technical Data...3 Outputs & Connections...5 Dimensions...6 - Shaft with max. 0 mm diameter - 0...5/0V, 4...20 ma analog

More information

n Measurable displacements between n Linearity: max. ± 0.05 % n Housing diameter 12.9 mm n Service life: 10 8 movements

n Measurable displacements between n Linearity: max. ± 0.05 % n Housing diameter 12.9 mm n Service life: 10 8 movements Potentiometric Displacement Sensor Miniature design Model 8709 Code: Delivery: Warranty: 8709 EN ex stock 24 months Application Potentiometric displacement sensors are used for direct, precise measurement

More information

Automotive Fasteners for Automotive Industry

Automotive Fasteners for Automotive Industry Automotive Fasteners for Automotive Industry PEINER Umformtechnik GmbH Woltorfer Straße 20-24 D-31224 Peine Phone + 49 (0) 5171 545-0 Fax + 49 (0) 5171 545-180 e- mail sales@peiner-ut.com Internet www.peiner-ut.com

More information

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Weighing System Evaluation Mounting DMS strain gauges (load cells), DMS amplifier

More information

Technical Data Sheet. T E C H N I C A L D A T A S H E E T Superprop. Mass 25 Mass 50 M AT 125 Superprop. MU Bridging

Technical Data Sheet. T E C H N I C A L D A T A S H E E T Superprop. Mass 25 Mass 50 M AT 125 Superprop. MU Bridging Technical Data Sheet Mass 25 Mass 50 M AT 125 Hydraulics Quickbridge MU Falsework MU Bridging Compact Bridging BarrierGuard 800 Instrumentation Mabey Hire Ltd. Structural Support & Bridging Bridge House,

More information

Rotary Position Technology Incremental Encoders

Rotary Position Technology Incremental Encoders -40 to 80 C Temperature Shock/vibration resistant Short-circuit protected Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection

More information

Installation and Operational Instructions for ROBA -DS couplings Type 95. _ (disk pack HF) Sizes

Installation and Operational Instructions for ROBA -DS couplings Type 95. _ (disk pack HF) Sizes 95. _ (disk pack HF) Sizes 6 22 Please read these Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to coupling failure, resulting

More information

Torque Measuring Flange

Torque Measuring Flange Force Torque Measuring Flange Digital Telemetry Based, Short-Design, Robust, High Accuracy Type 025DF... Type 025DF... torque measuring flanges operate on the strain gage principle. The integral, digital

More information

T40FH. Torque flange. Special features. Data sheet

T40FH. Torque flange. Special features. Data sheet T40FH Torque flange Special features - Nominal (rated) torques: 100kNm, 125kNm, 150kNm, 200kNm, 250kNm, 300kNm - Nominal (rated) rotational speed of 2000 rpm up to 3000 rpm - Compact design - Version for

More information

Design Guide. Original version of the design guide

Design Guide. Original version of the design guide Page 1 of 12 Original version of the design guide For Series Components Spieth locknuts (precision locknuts) MSR 58x1.5 MSR 60x1.5 MSR 60x2 MSR 62x1.5 MSR 65x1.5 MSR 65x2 MSR 68x1.5 MSR 70x1.5 MSR 70x2

More information

Operating Manual Series Load Pins

Operating Manual Series Load Pins Operating Manual 5301 Series Load Pins Safety note Use for intended purpose The force transducers in model series F5301 are intended for the measurement of static and dynamic tensile or compressive force.

More information

Models Tension/Compression Pancake Load Cell Model 3174 with tension base DESCRIPTION FEATURES

Models Tension/Compression Pancake Load Cell Model 3174 with tension base DESCRIPTION FEATURES Models 3174-3176 Model 3174 Model 3174 with tension base DESCRIPTION Models 3174, 3175, and 3176 are fatigue-resistant, low-profile tension and compression load cells that are well suited to materials

More information

PW6C. Single point load cells. Special features. Data sheet

PW6C. Single point load cells. Special features. Data sheet PW6C Single point load cells Special features - Max. capacities: kg... 40 kg - Aluminum - Accuracy class CMR & C6 - Off center load compensated - Shielded connection cable - Different cable lengths and

More information

CSG110 Strain Gauge Universal Amplifier

CSG110 Strain Gauge Universal Amplifier Quick Start Guide CSG110 Strain Gauge Universal Amplifier Sensor Solutions Source Load Torque Pressure Multi-Axis Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For more

More information

Model RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES

Model RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES Rod End In-line Compression/Tension Load Cell DESCRIPTION The Model RGH In-Line load cells are high quality, stainless steel, rugged load cells capable of withstanding significant off-axis loads, making

More information

Single point load cell

Single point load cell PW15AH Single point load cell Special features - Nominal load 10 kg... 100 kg - Stainless steel - High ratio of minimum verification interval Y - Industrial Footprint (SP4M) - Degree of Protection IP68;

More information

Sensors for Small Forces

Sensors for Small Forces Force Sensors for Small Forces 0,5... 0,5 N to 500... 500 N Type 9203, 9205, 9207, 9215A, 9217A These slim sensors are designed for dynamic and quasistatic tensile and compression forces. Depending on

More information

Technical data. Your advantages

Technical data. Your advantages Technical data Nominal torque: 50 Nm to 2.000 Nm, bidirectional Rotational speed: 10.000 rpm Accuracy: ±0,2 % Temperature range: -40 C to +85 C Protection class: IP50, IP65 Output signals: 0-10 V/4-20

More information

XXXX e. X d.. X X X a

XXXX e. X d.. X X X a The Heavy uty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS

More information

Heavy duty profiles. Heavy loads with maximum stability. Profile general overview... p Heavy duty profiles... S Load data... p.

Heavy duty profiles. Heavy loads with maximum stability. Profile general overview... p Heavy duty profiles... S Load data... p. Heavy loads with maximum stability Profile general overview... p. 366 Heavy duty profiles... S. 368 Load data... p. 372 Connection techniques... p. 374 Accessories... p. 384 Heavy duty profiles 365 Heavy

More information

Sensor Datasheet Collection

Sensor Datasheet Collection ISO 9001 REGISTERED Specials are Our Standard Sensor Datasheet Collection CONTENTS HR-DRO: HIGH RESOLUTION DIGITAL READOUT 3 THE RELS FAMILY: ROD-END LOAD SENSORS 4-15 S-RELS SERIES: STANDARD ROD-END LOAD

More information

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1 Force Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1 WIKA data sheet FO 51.18 Applications Crane systems and hoists Industrial weighing technology Machine building and plant

More information

RoHS. High shaft load capacity. Shock / vibration resistant

RoHS. High shaft load capacity. Shock / vibration resistant Due to their sturdy bearing construction in Safety Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up

More information

Weighing Instruments

Weighing Instruments GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Weighing Instruments System Evaluation

More information

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up to

More information

Magnetic Encoder MEM 22

Magnetic Encoder MEM 22 Description The MEM 22 is a magnetic incremental encoder. He is a reliable low cost hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder MEM22 is designed

More information

T40B. Torque Flange. Special features. Data sheet. Overall concept

T40B. Torque Flange. Special features. Data sheet. Overall concept T40B Torque Flange Special features - Nominal (rated) torques 50 N m, 0 N m, 200 N m, 500 N m, 1 kn m, 2 kn m, 3 kn m, 5 kn m and kn m - Nominal rated rotational speed up to 24000 rpm (depending on nominal

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up to

More information

eddyncdt 3010 Non-Contact Displacement Measuring Systems

eddyncdt 3010 Non-Contact Displacement Measuring Systems Eddy current sensors for displacement, distance and position Eddy current and inductive measurement system and sensors with micrometer resolution for linear measurement and displacement, distance and position

More information

ABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL

ABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL Main Features - Compact and heavy-duty industrial model - Interface: Bit-parallel, push pull ΠShort circuit proof - Housing: 58 mm - Shaft: 6 or 10 mm - Resolution: Max. 25 Bit =,554,42 steps over 4,096

More information

n Measuring range ,02 N m to N m n Clockwise and counter-clockwise torque n Low linearity deviation of ± 0.05 % F.S.

n Measuring range ,02 N m to N m n Clockwise and counter-clockwise torque n Low linearity deviation of ± 0.05 % F.S. Precision Torque Sensor Non-contact transmission for rotating applications Optional measurement of angle and speed Model 8661 Code: Delivery: Warranty: 2-3 weeks 24 months Application The 8661 precision

More information

XXXX e. X d.. X X X a

XXXX e. X d.. X X X a The Heavy Duty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS

More information

Model Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Model Tension/Compression Pancake Load Cell DESCRIPTION FEATURES Model 3173 Tension/Compression Pancake Load Cell DESCRIPTION The Model 3173 covers the lower capacity ranges of 200 pounds force to 3000 pounds force, while exhibiting the high performance characteristics

More information

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en T40FM Torque flange Special features Data Sheet - Nominal (rated) torque: 15 kn m, 20 kn m, 25 kn m, 30 kn m, 40 kn m, 50 kn m, 60 kn m, 70 kn m and 80 kn m - Nominal (rated) rotational speed up to 8000

More information

Optical encoder MEC22 HR

Optical encoder MEC22 HR Optical encoder MEC22 HR Description The MEC22 HR is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square

More information

Force and strain sensors.

Force and strain sensors. Force and strain sensors. Measure. Test. Control. Edition 2016 Force and strain sensors by Baumer combine tried and tested technology and sophisticated innovations. 1 Contents. Introduction 1 Product key

More information

CAN-IO Custom IO remote module

CAN-IO Custom IO remote module CAN-IO Custom IO remote module Main characteristics High customization Integrate different types of inputs/ outputs Up to 40 total channels DIN rail mount or plate Main applications Climatic chambers Autoclaves

More information

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications: GS series of wireless industrial sensors Strain gauge reader/ transmitter Features: Input: strain gauge Wheatstone bridge: 300ohms to 10kohms. Typical: 1000 ohms. Standard input range: up to 2mV/V full

More information

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering Change from one to two columns Data Sheet 10/10-3.61-EN Rev. D SensyTemp TSB (B R) Resistance thermometer for building automation, machine construction and environmental engineering Measurement made easy

More information

SETUP SUNSTAR 传感与控制 Model 3173 PERFORMANCE SPECIFICATIONS Load range 1 Accuracy 0.07 % Non-linearity Hysteresis Repeatabilit

SETUP SUNSTAR 传感与控制   Model 3173 PERFORMANCE SPECIFICATIONS Load range 1 Accuracy 0.07 % Non-linearity Hysteresis Repeatabilit Model 3173 DESCRIPTION The Model 3173 covers the lower capacity ranges of 200 pounds force to 3000 pounds force, while exhibiting the high performance characteristics of stiffness and accuracy. These load

More information

5-axis clamping system compact

5-axis clamping system compact 5-axis clamping system compact 395 5-axis clamping system compact Function We are setting standards with the new KIPP 5-axis clamping system compact in this field. The system was specifically designed

More information

TQ 402 & TQ 412 / EA 402 / Proximity System. 三協インタナショナル株式会社東京 :Tel: 大阪 :Tel: 名古屋 :Tel: FEATURES

TQ 402 & TQ 412 / EA 402 / Proximity System. 三協インタナショナル株式会社東京 :Tel: 大阪 :Tel: 名古屋 :Tel: FEATURES TQ 402 & TQ 412 / EA 402 / IQS 450 FEATURES Non-contacting measurement system based on eddy current principle TQ 402 Certified for use in potentially explosive atmospheres TQ 402 conforms to API 60 recommendations

More information

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1 Force Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1 tecsis data sheet FO 51.18 Applications Crane systems and hoists Industrial weighing technology Machine building and plant

More information

AC AC AC

AC AC AC AC104.01-10 AC104.01-100 AC104.01-500 Description The hermetic sealed industrial piezoelectric accelerometer model 104 is design to monitor the vibration in harsh industrial environment. It uses the industry

More information

EMSPA LINEAR MAGNETOSTRICTIVE TRANSDUCER WITH ANALOG OUTPUT. Magnetostrictive transducer. Main characteristics. Ordering code EMSPA 1000 S 10S 10 P A

EMSPA LINEAR MAGNETOSTRICTIVE TRANSDUCER WITH ANALOG OUTPUT. Magnetostrictive transducer. Main characteristics. Ordering code EMSPA 1000 S 10S 10 P A EMSP LINER MGNETOSTRICTIVE TRNSDUCER WITH NLOG OUTPUT Main characteristics EMSP is an absolute linear magnetostrictive transducer with analog interface.thanks to the absence of electric contact on the

More information

Torque Sensor. Torque. with Dual-Range-Option. Type 4503A...

Torque Sensor. Torque. with Dual-Range-Option. Type 4503A... Torque Torque Sensor with Dual-Range-Option Type 4503A... Type 4503A... torque sensors with built-in speed sensor operate on the strain gage principle. An integral, digital measurement conditioning system

More information

TQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES

TQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner TQ 402 & TQ 412 / EA 402 / IQS 452 FEATURES Non-contacting measurement system based on eddy current principle Certified

More information

Zero Point Clamping System. ZERO lock BALL lock

Zero Point Clamping System. ZERO lock BALL lock Zero Point Clamping System ZERO lock BALL lock kap3 kap 263 Technical information regarding ZERO lock Zero Point Clamping System Application The modularly designed, flexible ZERO lock Zero-Point Clamping

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0) DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

TQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES

TQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES Non-contacting measurement system based on eddy current principle Certified for use in potentially

More information

ELPF Load Cell DESCRIPTION

ELPF Load Cell DESCRIPTION Compact Tension/Compression Design 10 500 lbf High Level and mv Output High Stability Industry Standard Packing Resists Off Axis Load Components Full NIST Traceable 11 Point Calibration Shielded Teflon

More information

Resistance Thermometers Model Series TR7X0, Sheathed Design

Resistance Thermometers Model Series TR7X0, Sheathed Design Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features

More information

Torque Sensor. Torque. Dual-Range Sensor with Brushless Transmission. Type 4503A...

Torque Sensor. Torque. Dual-Range Sensor with Brushless Transmission. Type 4503A... Torque Torque Sensor Dual-Range Sensor with Brushless Transmission Type 4503A... Type 4503A... torque sensors with built-in speed sensor operate on the strain gage principle. An integral, digital measurement

More information

up to 200 C, 4007B... Technical Data 4007B, General Measuring range bar Overload bar Power supply ma* 1 Output signal (FS

up to 200 C, 4007B...   Technical Data 4007B, General Measuring range bar Overload bar Power supply ma* 1 Output signal (FS Pressure SUNSTAR 传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 E-MAIL: High Temperature Pressure Sensor 5 and 20 bar Version for Temperatures up to 200 C 4007B... Rugged pressure sensor for the measurement

More information

Technical data. Your advantages

Technical data. Your advantages Technical data Nominal torque: 0 Nm to 3.000 Nm, bidirectional Rotational speed: 10.000 rpm Accuracy: ±0,1 % Temperature range: +10 C to +100 C Protection class: IP54 Output signals: 0-10 V Output frequency:

More information

A shear beam load cell, with strain gauges, tested as a part of a weighing instrument. Manufacturer : Precia Molen Type : CSI.

A shear beam load cell, with strain gauges, tested as a part of a weighing instrument. Manufacturer : Precia Molen Type : CSI. Test certificate Page 1 of 4 Issued by Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands Notified Body Number 0122 In accordance with Applicant In respect of Paragraph 8.1 of the European Standard

More information

Accessories for sensors

Accessories for sensors Accessories for sensors Mounting and installation Adapters for pressure sensors: Hex AF width 27 ZBM 01 Adapter female thread G1/4 male thread G1/2 B, DIN EN 837-1 Part no.: 257276 Flat seal ring Cu 6.2x17.5x2.0

More information

Single point load cell

Single point load cell PW15AH Single point load cell Special features - Nominal load 10 kg... 100 kg - Stainless steel - High ratio of minimum verification interval Y - Industrial Footprint (SP4M) - Degree of Protection IP68;

More information

Inductive conductivity transmitter JUMO CTI-Junior

Inductive conductivity transmitter JUMO CTI-Junior M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 (0) 661 60 03-7 25 Fax: +49 (0) 661 60 03-6 81 E-Mail: mail@jumo.net

More information

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website:

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website: LCT100 Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website: www.anyload.com Email: info@anyload.com A. Basic Steps in Load Cell Testing using the LCT100: 1. Connect the load cell cable

More information

Product Information. ERN 1085 Incremental Rotary Encoder with Z1 Track

Product Information. ERN 1085 Incremental Rotary Encoder with Z1 Track Product Information ERN 1085 Incremental Rotary Encoder with Z1 Track 02/2018 ERN 1085 Rotary encoder with mounted stator coupling Compact dimensions Blind hollow shaft 6 mm Z1 track for sine commutation

More information

adaptivemechanical adaptive

adaptivemechanical adaptive Mechanical clamping elements mechanical 6 Content Product group 6 Sliding clamp, mechanical 6.2210 Clamping block, mechanical 6.2212 High-pressure spindle, mechanical with integral wedge system 6.2270

More information