Product overview. ISOMETER Insulation monitoring devices ISOSCAN Insulation fault location systems EDS

Size: px
Start display at page:

Download "Product overview. ISOMETER Insulation monitoring devices ISOSCAN Insulation fault location systems EDS"

Transcription

1 Product overview ISOMETER Insulation monitoring devices ISOSCAN Insulation fault location systems EDS

2 2

3 Find out today what will not happen tomorrow Reporting critical operating states today, so that unwanted incidents such as operational interruptions, costly material damage or even physical injuries do not happen. Safety of power supply To ensure electrical safety for people and electrical installations in an efficient way on a long-term basis, Bender offers insulation monitoring devices for all the key industries. In particular, these devices are used anywhere where a safe power supply is an essential requirement to prevent system failures, eliminate the risk of serious or fatal injuries and to avoid material damage. Top-level productivity and maximum safety for people and the electrical installation With Bender insulation monitoring devices for unearthed power supplies (IT systems) you are already using the technology of tomorrow with respect to reliability, measurement methods and design. Along with precise measurement technology, the ISOMETERs provide many functions for early detection and quality assurance with user-friendly and intuitive operation, reliable evaluation and simple communication. Fast localisation of insulation faults Bender insulation fault location systems enable fast localisation and elimination of insulation faults even during operation. Disconnection of the electrical installation is not required. Portable Bender solutions facilitate the use in large installations with sub-distributions. For more than 70 years, Bender has been a name for advanced technology using the latest Made in Germany measurement technology and outstanding technical expertise. Because of this, Bender offers an exceptionally long warranty period of five years. Contents Unearthed power supply systems 4 IT systems for information ahead of time 5 I nsulation monitoring devices ISOMETER Control and auxiliary circuits 6 Insulation fault location systems EDS...9 Insulation monitoring devices with locating current injector 20 Locating current injectors 2 Insulation fault locators ISOSCAN...22 Main circuits 8 Insulation fault locators with integrated transformer 23 Special applications 0 Accessories Coupling devices 6 Portable equipment for insulation fault location 24 Communication solutions...26 Gateways 7 IT systems used worldwide 28 Measuring instruments 8 Support during all phases 29 3

4 For a high level of operational and electrical system safety: Unearthed power supply systems (IT systems) Modern power supplies require maximum availability, safety and predictive information Given a wide variety of production processes, continuous competitive pressure, the impact of soaring costs and operational availability around the clock, the maximum possible electrical safety for power supplies is required. Although great care has been taken during the design and implementation phases and is continued throughout the maintenance cycle,electrical installations may nevertheless be impaired by factors such as humidity, ageing, dirt, mechanical damage, to mention but a few. Undetected insulation faults can be disastrous and costly, especially when factors such as production failure, repairs, device replacement or even unplanned service work are counted. Increasing availability - reducing costs The key objective of any system operator must be to recognise faults at an early stage and eliminate the cause in an efficient way. To achieve this objective, a possible solution uses unearthed power supplies (IT systems) with insulation monitoring. In IT systems, none of the active conductors is directly connected to earth. Therefore, on the occurrence of an insulation fault, only a small leakage current, essentially caused by system leakage capacitances, can flow. The upstream fuse does not trip, hence continuous power supply and operation is ensured. Prompt information about possible hazards is given by the ISOMETER which continuously monitors the insulation resistance between the system and earth. ISOMETER : A wide variety of solutions for all types of IT systems For the whole range of electrical power supplies, Bender provides appropriate solutions for most applications. Taking all types of system structures and loads into account, ISOMETER s using Bender's patented measuring principles guarantee reliable evaluation of the insulation resistance for: Nominal system voltages AC, DC or AC/DC up to 2 kv System configurations Ph, 3Ph, disconnected loads System leakage capacitances up to 2000 µf Response values from 0.2 kω to 0 MΩ Information advantage through the ISOMETER Principle of operation ISOMETER 4

5 IT systems - information ahead of time ISOMETER s in IT systems are an effective means of damage prevention, they enable increased productivity and optimised maintenance, which in turn lead to considerable reduction in costs. Bender's wide range of products allows the implementation of individual safety solutions and safeguards your investment. Optimised maintenance Recognise and signal insulation deteriorations early Localising faulty circuits automatically Optimising the planning of time and personnel resources Displaying information about the status of the electrical installation at a central location Remote diagnosis via Internet/Ethernet Increased protection against fire Recognising developing insulation faults at an early stage Minimising arcing faults, a frequent cause of fire S eparating areas prone to explosions and fire from the rest of the system by means of isolating transformers and monitoring them separately Improved economic efficiency Avoiding expensive and unscheduled stoppages Reducing personnel expenses and time and costs for maintenance Detecting weak points in the installation Supporting business decisions on investments High operational availabilty ON No interruption to operation in the event of a phase-to-earth fault No control malfunction in the event of insulation faults Electrical installations are kept at a high level of availability Monitoring electrical installations also during standstill Enhanced accident prevention Low touch currents in small and medium-sized installations o malfunctions in case of earth faults in the control circuits of equipment and N machines Higher permissible earthing resistance Higher earthing resistances, permissible, for example, for mobile power supplies 5

6 Maximum operational safety in control and auxiliary circuits ISOMETER IR420-D4 ISOMETER IR25Y-4 ISOMETER IR425 Circuits Control circuits Voltage system Auxiliary circuits Main circuits 3(N)AC AC V, DC V AC/DC V AC AC/DC DC AC V Frequency range fn AC Hz DC DC, AC Hz System leakage capacitance Ce µf Response value Ran kω Response value Nominal system voltage Un Alarm contacts 2 changeover contacts changeover contact 2 changeover contacts Operating principle N/O or N/C operation N/C operation N/O or N/C operation Response time tan (at RF = 0.5 x Ran and Ce = µf) s 6s 2s Start-up delay t 0 0 s 0 0 s Response delay ton 0 99 s 0 99 s Indication LC display Power On LED Installation Alarm LEDs DIN rail Screw mounting Ordering information Nominal voltage Un Supply voltage ) US AC V, Hz DC /AC V AC/DC V, Hz Device version with screw terminals on request. ) Absolute values Accessories 6 designation Art. No. Mounting clip for screw mounting ( piece per device) B Art. No. AC 6 72 V, Hz/DC V IR420-D4- B AC/DC V/DC Hz IR420-D4-2 B = Un IR25Y-4 B AC 6 72 V, Hz/DC V IR425-D4- B AC/DC V/DC Hz IR425-D4-2 B

7 In localised areas, such as machine control systems or safety lighting where space is limited, control and auxiliary circuits provide additional functions, such as command output, interlocking, messaging and measuring. For these circuits, particular emphasis is placed on operational reliability. Example applications AC control circuit with IR420 AC/DC control circuit with IR425 DC control circuit with IR425 7

8 Circuits High system availability in main circuits ISOMETER IR470LY ISOMETER IR470LY2-406 ISOMETER IRDH275(B) ISOMETER IRDH375(B) ISOMETER IR575 Control circuits Auxiliary circuits ISOMETER iso685 ISOMETER iso685p-425 Main circuits Voltage system 3(N)AC AC AC/DC DC Nominal system voltage Un AC, 3(N)AC V ) AC, 3(N)AC V ) AC, 3(N)AC V, DC 0 50 V ) AC V, DC V AC, 3(N)AC V DC V ) AC, 3(N)AC V DC V ) AC, 3(N)AC V DC V AC Hz AC Hz DC, AC 460 Hz DC Hz DC, AC Hz DC, AC Hz DC, AC Hz System leakage capacitance Ce µf µf Nominal voltage range Un expandable (via coupling devices) AGH204S-4/AGH520S Response value Ran kω Installation Communication Frequency range fn LC display AGH50W-4/ AGH204S-4/AGH520S AGH204S-4/AGH520S/ AGH676S AGH50W-4/ AGH50W-4/ AGH204S-4/AGH520S/ AGH204S-4/AGH520S/ AGH676S-4 AGH676S Prewarning display RS-485 interface DIN rail Screw mounting Panel mounting/wall fastening Ordering information Nominal voltage Un Supply voltage US Art. No. AC 230 V IR470LY-40 B AC V, DC V IRDH B AC 24 V IR470LY-40 B DC V IRDH ) B AC 42 V IR470LY-402 B DC V IRDH ) B AC V IR470LY-403 B AC 400 V IR470LY-405 B AC 500 V IR470LY-406 B AC 690 V IR470LY-407 AC 440 V ) ) 3) Supply voltage US Art. No. 2) 3) AC V, DC V IRDH275B-435 2) 3) B DC V IRDH275B-4273) B DC V IRDH275B-4253) B B AC V, DC V IRDH ) 3) B IR470LY-408 B DC V IRDH ) B ) DC V IR470LY-402 B DC V) IR470LY-4023 B DC V IRDH375B-4273) B AC 230 V IR470LY2-406 B AC V ) / DC 0 50 V ) IR ) B AC/DC V iso685-d B AC V, AC V/ DC V AC 6 72 V, DC V IR B AC V, DC V AC/DC 8 30 V iso685p B AC V ) 8 Nominal voltage Un AC V ) / DC V ) AC V, DC V IRDH375B-435 2) 3) AC 0 480/ DC B Absolute values 2) Device versions with GOST certificate available. Device version "Option-W" with increased shock and vibration resistance: Indicated by the letter "W" at the end of the order number.

9 Main circuits provide the power supply for electrical installations or buildings. These circuits include equipment for generating, converting, distributing, switching and consuming electrical energy. From the user's point of view, different types of loads should be distinguished between: pure AC loads (e.g. motors), AC/DC loads containing electronic components (e.g. converters) and pure DC loads (e.g. battery systems). Example applications AC main circuits with one motor AC/DC main circuits with a variable-speed drive COM460IP Coupled IT systems 9

10 Recognising faults at an early stage in specific applications AC, DC or AC/DC medium voltage systems Circuits ISOMETER IRDH275BM-7 Medical locations Photovoltaic ISOMETER IR427 ISOMETER 07TD47 ISOMETER isopv ISOMETER isopv425 ISOMETER isopv685 ISOMETER isopv685pfr Control circuits Auxiliary circuits Main circuits Voltage system 3(N)AC AC AC/DC DC Nominal system voltage Un AC, 3(N)AC/DC kv AC V ) AC 230 V AC 27 V via AGH-PV 3(N)AC V DC 0 00 V ) DC 0 00 V, AC V ) DC V DC V Frequency range fn DC, AC Hz AC Hz AC Hz via AGH-PV DC, Hz via AGH420 DC, Hz via AGH420 DC, Hz via AGH420 DC, Hz Response value Ran kω Installation Indication System leakage capacitance Ce µf LC display Power On LED Alarm LEDs DIN rail Screw mounting Ordering information Nominal system voltage Un ) 2) 0 Supply voltage ) US Art. No. AC V IRDH275BM-7 B AC V, Hz AC V, Hz IR427-2 B ) AC 230 V, Hz AC 230 V, Hz 07TD47 B AC 27 V, Hz AC 27 V, Hz 07TD47-33 B AC V, DC 0 00 V DC V isopv AGH-PV consisting of: isopv-327 (B W), AGH-PV (B W) B W AC V, DC 0 00 V AC V, DC V isopv AGH-PV consisting of: isopv-335 (B W), AGH-PV (B W) B W AC V, DC V AC V, Hz/DC V isopv425-d4-2 with AGH420 B ) DC V DC 8 30 V isopv B DC V DC 8 30 V isopv685pfr-425 B Absolute values Device version with screw terminals on request.

11 Our product range includes a variety of products, such as ISOMETER s for low-resistance DC systems, systems containing AC/DC medium-voltage converters up to 2 kv, mobile generators or disconnected loads. Should you have any questions, please do not hesitate to contact our Technical Sales Department. Standard-compliant solutions for Medical locations Photovoltaic Installations with a low level of insulation Disconnected loads Mobile generators Electric mobility Railway, rolling stock Example applications Monitoring of medium-voltage drives with IRDH275 and coupling device AGH675S-7 Rf Rf Rf Ce <2000µF PV generator unearthed (IT system) with nominal voltage DC 00 V and ISOMETER isopv with coupling device AGH-PV

12 Specific applications Circuits Installations with a low level of insulation Disconnected loads Mobile generators ISOMETER isolr275 ISOMETER IR470LY2-60 ISOMETER IR420-D6 ISOMETER IR423 ISOMETER IR23 Control circuits Auxiliary circuits Main circuits Voltage system 3(N)AC AC AC/DC DC via AGH-LR 3(N)AC V DC 0 00 V ) AC, 3(N)AC V ) Offline AC V AC V Frequency range fn via AGH-LR DC, Hz AC Hz via AGH520S, AGH676S-4 AC Hz AC Hz System leakage capacitance Ce µf Response value Ran kω /23 Installation Indication Nominal system voltage Un LC display Power On LED Alarm LEDs DIN rail Screw mounting Ordering information Nominal system voltage Un Supply voltage US) Art. No. DC V isolr AGH-LR-3 consisting of: isolr (B W), AGH-LR-3 (B W) B W AC V, DC V isolr AGH-LR-3 consisting of: isolr (B W), AGH-LR-3 (B W) B W AC 230 V IR470LY2-60 B AC V IR470LY2-603 B AC 400 V IR470LY2-605 B DC V) IR470LY2-602 B AC 6 72 V, Hz/DC V IR420-D6- B IR420-D6-2 B IR420-D64-2 IR423-D4- B B AC V, DC 0 00 V ) AC V AC V, Hz/DC V AC 6 72 V, Hz/DC V AC V AC V, Hz 2 ) Absolute values AC/DC V, Hz IR423-D4-2 B AC 6 72 V, Hz/DC V IR423-D4W- B W AC/DC V, Hz IR423-D4W-2 B W US = Un IR23P-4-2 B

13 Example applications Monitoring of de-energised loads with IR420-D6 (offline) Monitoring of mobile generators with IR423 3

14 Specific applications Circuits Electric mobility Railway, rolling stock ISOMETER IR55 ISOMETER isoev425 ISOMETER isorw425 Control circuits Auxiliary circuits Main circuits Voltage system 3(N)AC AC AC/DC Nominal system voltage Un DC V DC 0 00 V AC 0 793V ) AC/DC V Frequency range fn AC Hz DC, Hz DC Response value Ran kω Installation Indication System leakage capacitance Ce µf LC display Power On LED Alarm LEDs DIN rail Screw mounting Ordering information Nominal system voltage Un AC V, DC V ) 2) 3) 4 Supply voltage ) US DC 0 36 V Art. No. IR B V4 IR B V4 IR B CV43) IR B CV43) AC V, Hz/DC 0 00 V AC V, Hz/DC V isoev425-d4 with AGH420 B ) AC/DC V AC V, Hz/DC V isorw425-d4w-4 B W2) Absolute values Device version with screw terminal on request. Custom setting possible

15 Example applications Charger Vehicle coupler iso-f HV DC Circuit AC Load enable relay Drive enable relay IMD vehicle Monitoring of unearthed DC drive systems in electric vehicles with IR55 TN-C-S system Source Distribution Installation Feeder Input Vehicle Cable assembly Connector Vehicle inlet DC charger Electric vehicle L L2 L3 N PEN RCD required by IEC Mode 4 IT system PE Load Switch F DC + F DC - F RB Earthing at the source L IMD Control Pilot Function = N CP PP Note: Only one IMD may be active in each interconnected IT system M I n DC 6 ma (Option) Control Pilot Function PE Earthing in the distribution RAE CP PE RPE RA CP Inverter F DCIsolating transformer RESS V = PFC RCD type A DC contactor F DC+ Air condition other consumers = AC on-board charger with electrical separation IMD (Option) = 4 V on-board power system (electrical separated) Electrical Chassis / Protective equipotential bonding RTyre Monitoring of unearthed DC circuits for charging electric vehicles with isoev425 5

16 Accessories Coupling devices AGH50W-4 AGH204S-4 Application Device family Nominal system voltage Un IR470LY AGH675S-7 AGH676S-4 AGH675S-7MV5 AC/3(N)AC/DC 0...7,2 kv AC/3(N)AC 0 2 kv AC, 3(N)AC, DC 0 5,5 kv Extension of the nominal voltage range for ISOMETER s AC 0 50 V, DC V AC V / AC V AC/3(N)AC 0...7,2 kv IRDH275/375 IRDH275BM-7 IR420-D64 Nominal system voltage US Art. No. AC 0 50 V/DC V AC V/0 300 V AGH50W-4 B AGH204S-4 B (N)AC V AGH520S B AGH675S B AGH675S B AC/ 3(N)AC 0 2 kv, Hz AGH676S-4 B AC, 3(N)AC, DC 0 5,5 kv, Hz AGH675S-7MV5-500 B AC, 3(N)AC, DC 0 7,2 kv, Hz 6 AGH520S

17 Gateways System requirements Connection Functions Application COMTRAXX COM460IP COMTRAXX COM46MT COMTRAXX COM462RTU FTC470XDP COMTRAXX CP700 BMS-Ethernet-Gateway BMS-Ethernet-Gateway BMS-Modbus/RTU-Gateway BMS-PROFIBUS DP-Gateway Condition Monitor/Gateway Protocol input BMS BMS BMS BMS BMS, Modbus/RTU/TCP Protocol output Ethernet, Modbus/TCP Ethernet, Modbus/TCP Modbus/RTU PROFIBUS DP Ethernet, Modbus/TCP Indication LCD/LED LED LCD/LED LED 7 colour LCD Alarm messages, 2), 2, 3) Measured values, 2), 2, 3) Device parameter setting ) Alarm list ), 3) History memory ) ) Diagrams ), 3) Visualisation ) ) notification ) ) Device tests, 2) Data logger ) BMS 4) 4) ), 2) ) screw-type terminal screw-type terminal screw-type terminal screw-type terminal pluggable screw terminals Output RJ 45 RJ 45 screw-type terminal 9-pin SUB-D RJ 45 Supply voltage US AC/DC V AC 6 72 V, DC 6 94 V AC/DC V AC / DC V AC/DC V DC 24 V Internet Explorer, Opera, Firefox etc. with Silverlight plugin Browser Internet Explorer, Opera, Firefox etc. Internet Explorer, Opera, Firefox etc. with Silverlight plugin Ordering information Supply voltage/frequency range US Supply voltage/frequency range US for UL applications Power consumption Art. No. AC/DC V 5), Hz AC V, ma, Hz/ DC V, 0 35 ma 5 40 VA, 3.8 W COM460IP B AC 6 72 V, Hz/DC 6 94 V AC 6 72 V, ma, Hz/ DC 6 94 V, ma 4 VA COM460IP-24V B AC/DC V 5), Hz AC V, ma, Hz/ DC V, 6 2 ma VA, 2.4 W COM46MT B AC/DC V 5), Hz AC V, ma, Hz/ DC V, 0 35 ma VA, 2.4 W COM462RTU B AC/DC V FTC470XDP B DC 24 V/± 25 % typ. W, max. 26 W CP7006) B Available functions on the web server Accessible by means of a PC using a browser Available via protocol 3) On the device's own LC display 4) Limited device parameter setting 5) Absolute values 6) Device version with GOST certificate available. ) 2) 7

18 Accessories Measuring instruments Input current μa 0 20 ma μa 0 20 ma Dimensions (mm) 72 x x x x 96 Device family IR470LY IR470LY2-6 IRDH275/375 IRDH275B/375B IRDH575 Ordering information Scale Input current Dimensions Midscale (SKMP) 72 x 72 mm 20 kω μa 96 x 96 mm Division 0 20 ma 96 x 96 mm 20 kω μa 96 x 96 mm.2 MΩ 0 20 ma 8 20 kω 72 x 72 mm 20 kω Art. No B S-42 B B S-42 B B S-42 B B B S-42 B

19 Insulation fault location system EDS Fast localisation of insulation faults Fast localisation and elimination of insulation faults is required by DIN VDE (VDE ):. The IRDH575 in combination with the EDS system is a modular system to solve this problem. The application areas for EDS systems are highly diverse. They are operated/used for main and control circuits in, for example: Power stations Hospitals Paper industry Shipbuilding Oil and natural gas industry Traffic engineering Mining, open-cast mining Industrial plants Rolling mills Mechanical engineering Advantages of an insulation fault location system EDS isconnection of the electrical D installation is not required, insulation fault location takes place during operation ombination with portable C insulation fault location systems EDS3090/3090PG and EDS309/309PG Fast localisation of faulty circuits Reduced maintenance and repair costs I nformation about the location of the fault is centrally displayed COM460IP COM460IP Application example 9

20 Insulation monitoring devices ISOMETER with locating current injectors ISOMETER IRDH575 Application Nominal system voltage Un Supply voltage US Main circuit Control circuit Un (B) 3AC/AC V DC V (B version) Un (B) 3AC/AC V/DC V (version IRDH575B-4227, IRDH575B-4235) Un (B2) 3AC/AC V DC V (B2 version) Un (B2) AC V DC V (version IRDH575B-435, IRDH575B2-435, IRDH575B-4235) AC V DC V (version IRDH575B-435, IRDH575B2-435, IRDH575B-4235) DC 9,2 72 V (version IRDH575B-427, IRDH575BW-4227) DC 9,2 72 V (version IRDH575B-427, IRDH575BW-4227) 0/25/50 ma /2,5 ma ma kω Locating current Installation ISOMETER isomed427p Response values kω 0 MΩ kω 0 MΩ LC display 4 x 20 characters 4 x 20 characters Medical locations Un max AC V Us = Un Alarm relay 3 changeover contacts 3 changeover contacts changeover contact Interface/protocol RS-485 (BMS) RS-485 (BMS) RS-485 (BMS) Address range DIN rail Screw mounting Panel mounting/wall fastening Ordering information Nominal system voltage Un AC V AC V AC V DC V DC V DC V AC V, Hz Supply voltage US 4) Art. No. DC 9,2 72 V IRDH575B-4272) B AC V/DC V IRDH575B-435 B DC 9,2 72 V IRDH575B-4227) B AC V/DC V IRDH575B-4235 B DC 9,2 72 V IRDH575B2-427 B AC V/DC V IRDH575B2-435 B = Un isomed427p-2 B Measuring voltage Um 0 V for version for use in control circuits. Device version with GOST certificate available. 3) Absolute values 4) Device Option-W with increased shock and vibration resistance : Indicated by the letter W at the end of the order number. ) 2) 20

21 Locating current injectors for existing installations in combination with an existing insulation monitoring device Application Circuits Control circuits ISOSCAN PGH47 ISOSCAN PGH473 ISOSCAN PGH474 Stationary Stationary Stationary (med. locations) Main circuits Voltage system 3(N)AC AC AC/DC AC, 3(N)AC V DC V AC, 3(N)AC V DC V AC, 3(N)AC V DC V DC Nominal voltage Un max Response value Ran kω Installation System leakage capacitance Ce µf DIN rail Screw mounting Panel mounting/wall fastening Ordering information Circuits Main circuit Main circuit, med. locations Control circuit ) Locating current 25/0 ma ma 2.5/ ma BMS bus address range Supply voltage US AC Art. No. AC 230 V PGH47 B AC V) PGH47-3 B DC V) PGH47-2 B DC V) PGH47-23 B AC 230 V PGH47E B AC 230 V PGH474 B AC 230 V PGH474E B AC 230 V PGH473 B AC V) PGH473-3 B DC V) PGH473-2 B Absolute values 2

22 Insulation fault locators ISOSCAN EDS460-D/DG) EDS46-D Main circuit EDS490-D EDS49-D EDS460-L EDS46-L EDS490-L EDS49-L Control circuit US: DC 6 94 V, AC 6 72 V, Hz EDS460-D- EDS460-DG- ) EDS46-L- EDS490-D- EDS490-L- EDS460-L- EDS46-L- EDS490-L- EDS49-L- US: AC/DC V AC Hz EDS460-D-2 EDS460-DG-2 ) EDS46-L-2 EDS490-D-2 EDS490-L-2 EDS460-L-2 EDS46-L-2 EDS490-L-2 EDS49-L-2 Response value 2 0 ma 0.2 ma 2 0 ma 0.2 ma 2 0 ma 0.2 ma 2 0 ma 0.2 ma Residual current indication 00 ma 0 A ) 0 ma A 00 ma 0 A 0 ma A 00 ma 0 A 0 ma A 00 ma 0 A 0 ma A Scanning time < 0 s for up to 080 measuring channels Parameter setting function Indication LC graphical display 7-segment display/led indication Error code indication Number of measuring channels 2 Address range 90 Internal clock (RTC) History memory Alarm relay "Common alarm 2 x changeover contact Alarm relay per channel ) 2 x N/O contact 2 x N/O contact E DS460-DG- particularly for localising insulation faults in DC IT systems with a number of branch circuits with high system leakage capacitances. Residual current indication: 20 ma 2 A Ordering information Circuits Measuring range EDS function RCM function Alarm relay per channel Supply voltage2) US AC 6 72 V, Hz/ DC 6 94 V Control circuit AC/DC V, AC Hz ma 0 ma A AC 6 72 V, Hz/DC 6 94 V 2 x N/O contact 4) 22 EDS46-L- B LC graphical display EDS46-D-2 B segment display/led indication EDS46-L-2 B LC graphical display EDS49-D- B segment display/led indication EDS49-L- B B EDS460-D- B segment display/led indication EDS460-L- B LC graphical display EDS460-D-2 B segment display/led indication EDS460-L-2 B LC graphical display EDS490-D- B segment display/led indication EDS490-L- B LC graphical display EDS490-D-2 B segment display/led indication EDS490-L-2 B AC 6 72 V, Hz/DC 6 94 V LC graphical display EDS460-DG-3) 4) B AC/DC V, AC Hz LC graphical display EDS460-DG-23) 4) B AC 6 72 V, Hz/DC 6 94 V 2 x N/O contact Absolute values Device version with GOST certificate available. Device version "Option-W": with increased shock and vibration resistance. Measuring current transformers on request 7-segment display/led indication LC graphical display 00 ma 0 A 3) B B AC/DC V, AC Hz 2) EDS46-D- EDS49-L-2 AC/DC V, AC Hz LC graphical display EDS49-D-2 00 ma 2 A Art. No. LC graphical display AC 6 72 V, Hz/DC 6 94 V 2 50 ma 7-segment display/led indication AC/DC V, AC Hz Main circuit Indication

23 Insulation fault locators ISOSCAN with integrated measuring current transformers ISOSCAN EDS50 ISOSCAN EDS5 Application Stationary Stationary, Medical locations Voltage system Main circuit Control circuit 3(N)AC AC AC/DC DC acc. to characteristic curve acc. to characteristic curve Response value Ran kω acc. to characteristic curve acc. to characteristic curve Installation Nominal voltage Un max System leakage capacitance Ce µf DIN rail Screw mounting Panel mounting/wall fastening Ordering information ) Response value Circuits Measuring range Control circuit ma 0.5 ma A Main circuit 5 25 ma 5 ma 0 A EDS function RCM function Supply voltage ) US Art. No. AC 7 24 V, Hz/ DC 4 28 V EDS5 B EDS50 B Absolute values 23

24 Portable equipment for insulation fault location Locating current injector PGH Application Nominal system voltage Un Main circuit Control circuit energised offline energised 3AC, AC V DC V 3AC, AC V DC V AC V, DC V US AC 230 V PGH85 PGH86 PGH83 US AC V PGH85-3 PGH86-3 PGH83-3 Locating current IL max. 0/25 ma 0/25 ma /2.5 ma Insulation fault locator EDS95P LC display 3 x 6 characters Evaluating current IΔL ma Response value 0.2 /2 0 ma selectable Measuring clamps PSA mm mm 5 mm PSA3052 PSA365 (optional) PSA3320 PSA3352

25 Complete systems EDS3090 EDS309 Application range Main circuits Control circuits EDS309 components Operating manual Insulation fault locator Terminal connector 4 mm Adapter BNC/4 mm plug for transformers Adapter BNC-PS2 for WF transformers, optional Plug-in power supply unit for EDS95P Locating current injector Power supply cable for PGH8... Safety measuring lead, black Safety measuring lead, green/ yellow Safety claw grip, black Safety claw grip, green/yellow Coupling device, optional (EDS3096PV only: included with delivery) Measuring clamps 20 mm Measuring clamps 52 mm Measuring clamps 5 mm, optional EDS set, optional Measuring clamps Aluminium case with carrying strap PGH8 with accessories for Device type EDS95P with accessories EDS3090 EDS95P PSA3020 PSA3052 PSA365 EDS3090PG EDS95P PGH AGE85 PSA3020 PSA3052 PSA365 EDS3090PG-3 EDS95P PGH AGE85 PSA3020 PSA3052 PSA365 EDS309 EDS95P PSA3320 PSA3352 EDS309PG EDS95P PGH PSA3320 PSA3352 EDS309PG-3 EDS95P PGH PSA3320 PSA3352 EDS3092PG EDS95P PGH83 PGH PSA3320 PSA3020 PSA3352 PSA3052 EDS3096PG EDS95P PGH AGE85 PSA3020 PSA3052 PSA365 EDS3096PG-3 EDS95P PGH AGE85 PSA3020 PSA3052 PSA365 EDS3096PV EDS95P PGH AGE85 2 x PSA3052 Ordering information Main circuits Control circuits with EDS without EDS with EDS without EDS EDS460/490 Nominal voltage Un AC V, Hz/DC V AC V, Hz/DC V AC V, Hz/DC V EDS46/49 AC V, Hz/DC V Supply voltage US EDS3090 B EDS3090PG B AC V, Hz EDS3090PG-3 B AC 230 V, Hz EDS3096PG B AC V, Hz EDS3096PG-3 B EDS309 B AC 230 V, Hz EDS309PG B AC V, Hz EDS309PG-3 B EDS3092PG B EDS3096PV B AC V, Hz/DC V AC V, Hz/DC V AC 230 V, Hz AC V, Hz/DC V AC 230 V, Hz AC V, Hz/DC V Art. No. AC 230 V, Hz 25

26 Bender monitoring systems seamless communication Modern communication Due to the fact that increasing demands are placed on communication capability, data transparency and flexibility, the use of modern fieldbus and network technologies has become a must. Hence, operating, warning and fault messages via the Web or the network, for example, substantially contribute to increasing the transparency of power supply systems, and also allow a fast reaction to critical operating states. In addition, important messages can be transferred via SMS or s to the mobile phones or laptops of service personnel. Early information about the location and cause of a fault allow time and cost-efficient deployment of service personnel and can avoid equipment failure or damage to expensive devices. Web server Visualisation Electrical Safety Management The term "Electrical Safety management" means that Bender provides coherent solutions for the electrical safety of power supplies in all areas. Carefully matched products and systems with innovative measuring techniques, communication solutions for the visualisation of data from Bender monitoring systems as well as easy connection to fieldbus systems and to SCADA systems (Supervisory Control and Data Acquisition) provide the maximum possible safety, economic efficiency and transparency. The range of products is completed by comprehensive services, which extend right through the whole service life of the products. System overview Integrated functions Solution for BACnet Report Parameter Modbus/TCP... Solution for OPC Ethernet CP700 COM460IP COM460IP ext. BMS bus Modbus RTU MK2430 MK800 MK800 MK800 PEM TM MK800 COMTRAXX COMTRAXX PEM ATICS-4-XXXA-DIO ATICS U2 U M I3 KNX/LON U3 BMS bus BMS bus BMS bus BMS bus BMS bus ATICS-2-XXA-ISO ATICS U2 U M I3 Digital In/Out 26 ProfiBus-DP Digital In/Out Modbus RTU U3 T IL RISO

27 COM460IP BMS-Ethernet-Gateway that is used to convert data from the Bender-BMS bus into TCP/IP protocols. COM462RTU The BMS-Modbus/RTU gateway COM462RTU contains a Modbus/RTU slave that converts BMS data for a Modbus master. MK800 Universal alarm indicator and test combination for optical and acoustic signalling of alarm messages from BMS capable Bender monitoring systems. MK2430 Universal alarm indicator and test combination for optical and acoustic signalling of alarm messages from BMS capable Bender monitoring systems. CP700 Condition Monitor for Bender BMS devices and universal measuring devices. 27

28 IT systems used worldwide For all IT systems (unearthed systems) the standard IEC : Protection for Safety - Protection against electric shock applies. According to chapter an Insulation Monitoring Device (IMD) shall be provided to indicate a first insulation fault by an audible and/or visual signal in all cases where an IT system is used for reasons of continuity of supply. Additionally it is recommended that the first fault should be eliminated with the shortest practicable delay. In practice this can be realized e.g by an Insulation Fault Location Systems (IFLS) according to IEC :2009. Area of application Application field General Electrical Installations Typical device Standards and regulations Main Circuits iso685,irdh275, IRDH375, IRDH575, EDS460, EDS3090 IEC :2005, modified -Low-voltage electrical installations Part 4-4: Protection for safety Protection against electric shock, EN 5078:997 Electronic equipment for use in power installations, IEC 6203:2003 Electronic equipment for use in power installations, IEC 6800 series Adjustable speed electrical power drive systems Auxiliary and (Control circuits) IEC :20/A:202 (Clause 557), IR420, IR425, iso685, EDS46, HD :203 Low-voltage electrical installations EDS309 Part 5-557: Selection and erection of electrical equipment - Auxiliary circuits Verification iso685, IRDH275,IRDH375, IRDH575 IEC : ,Low voltage electrical installations verification, IEC :2005, modified Low-voltage electrical installations Part 4-4: Protection for safety Protection against electric shock Energy and Utilities Auxiliary circuits IR420, IR423, IR425, iso685 HD :203 Low-voltage electrical installations Part 5-557: Selection and erection of electrical equipment - Auxiliary circuits Wind turbines IR425, iso685, IRDH575, EDS460 IEC 6400-: A: 200 Wind turbines Part : Design requirements, IEC :2006 Wind turbines Part 2: Design requirements for small wind turbines Photovoltaic isopv, isopv425, isopv685, EDS460, EDS3096PV IEC : Part 7-72: Requirements for special installations or locations - Solar photovoltaic (PV) power supply Renewable Energies Resistance welding IEC 6235-:2008); Resistance welding equipment Part : Safety requirements for design, manufacture and installation (Production) Machinery, Cranes iso685, IRDH275, IRDH375, IRDH575, EDS460, EDS3090, isolr275, iso685pfr IEC : Safety of machinery Electrical equipment of machines Part : General requirements, IEC : Safety of machinery Electrical equipment of machines Part 32: Requirements for hoisting machines, IEC :2009, modified Safety of machinery Electrical equipment of machines Part 33: Requirements for semiconductor fabrication equipment Medical applications Group 2 locations isomed427p, 07TD47, IR426- IEC :2002- Electrical installations of buildings D47, EDS46 Part 7-70: Requirements for special installations or locations Medical locations Data Center Power Supplies isorw425 ETSI EN V.. (203-0) Environmental Engineering (EE); Earthing and bonding of 400 VDC data and telecom (ICT) equipment Electric vehicle IR , IR , IR , IR , iso65c ISO6469 Charging isoev425, IR55-320, IR IEC :204 Electric vehicle conductive charging system Part 23: DC electric vehicle charging station Manufacturing E-Mobility Ships Oil, Gas, Mining, Ships Offshore 28 IEC series Electrical installations in ships. IEC series Mobile and fixed offshore units electrical installations Fixed installations IR25, IR470, IRDH265, IRDH365, IRDH275, IRDH575, EDS460 EN 5022-:20 + A:20 Railway applications Fixed installations Electrical safety, earthing and the return circuit Part : Protective provisions against electric shock, EN :200 Railway applications Fixed installations Electrical safety, earthing and the return circuit Part 2: Provisions against the effects of stray currents caused by d.c. traction systems, CLC/TS 50562:20 Railway applications Fixed installations Process, measures and demonstration of safety for electric traction systems Rolling stock isorw685, isorw425 EN 5055:2007 Railway applications Electronic equipment used on rolling stock, EN 5053:204 Railway applications Rolling stock Protective provisions relating to electrical hazards Railway IMD, IFLS iso685, IRDH275, IRDH375, IRDH575, EDS460, EDS3090 Iso685, IRDH275, IRDH375, IRDH575, EDS460, EDS46, EDS3090 Electrical safety in low voltage distribution systems up IMD s, IRDH575, EDS460, to 000 V a.c. and 500 V EDS46, EDS50, EDS5, d.c. Equipment for testing, EDS3090, EDS309 measuring or monitoring of protective measures IEC : Corrigendum Part 8: Insulation monitoring devices for IT systems, IEC :2009 Part 9: Equipment for insulation fault location in IT systems IEC, :204 Part 5: Functional safety requirements for insulation monitoring devices in IT systems

29 Support at all stages All-round service for your installation: Remote, by phone, on-site S o on c ti vices f de g & Project scheduling Ma int ena nce tion Installa ars for min Regular se to proaches p a d e t n user-orie solutions plementation dards al im practic e of the latest stan dg or a knowle ruenberg G e tr n e c ing In the train you. ar e location n m m o &C From planning to modernisation Our know-how and our expertise is at your disposal in all project phases. Furthermore, our first-class service ensures you the maximum safety for your electrical installations. The service we offer range from telephone support through repairs to on-site service with state-of-the-art measuring devices and professional employees. Convincing benefits: n High availability of your installation by responding faster to fault messages n Automatic control, analysis, correction, readjustments/updates are possible n Competent assistance on changing settings and with updates n Regular checking of your installations/power quality/monitoring devices n Significant cost reduction by reduced downtimes and shorter service times o i t a s i n r e Operation Many service activities, fault clearance, but also analysis and inspections, can be carried out by remote maintenance no technician needs to be on-site, saving you time and money. M od & iss io io at er nin Op n Competent service for maximum safety and high availability of your installation Expa nsio n& n ele Expansion & M ode rni sa tio ning & Concept Plan &M na te ain nc 29

30 Bender your contact for electrical safety Product overview Product overview Residual current monitoring Power Quality AC, pulsed DC and AC/DC sensitive residual current monitors RCM, RCMA, RCMB Electronic measuring and monitoring relays Multi-channel, AC, pulsed DC and AC/DC sensitive residual current monitoring systems RCMS Product overview ISOMETER Insulation monitoring devices ISOSCAN Insulation fault location systems EDS 30

31 3

32 Distributed in Australia exclusively by: Captech Pty Ltd 3/40 Edina Road Ferntree Gully, VIC 356 Ph: E:

Product overview Insulation monitoring devices A-ISOMETER Insulation fault location systems EDS

Product overview Insulation monitoring devices A-ISOMETER Insulation fault location systems EDS 1 Product overview Insulation monitoring devices A-ISOMETER Insulation fault location systems EDS 1 BENDER Group For a high level of operational and electrical system safety: Unearthed power supply systems

More information

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an EDS309 Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an equipment for insulation fault location EDS309x_D00012_02_D_XXEN/11.2018

More information

The Power in Electrical Safety

The Power in Electrical Safety The Power in Electrical Safety Main Catalogue Edition BENDER Group Main Catalogue Edition Subject to change! Bender GmbH & Co. KG, Germany The catalogue and the articles and illustrations which it contains

More information

ISOMETER IRDH575. Approvals

ISOMETER IRDH575. Approvals Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation

More information

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an EDS309 Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an equipment for insulation fault location EDS309x_D00012_00_D_XXEN/05.2015

More information

Renewable energy Reliable and efficient use of the power of nature

Renewable energy Reliable and efficient use of the power of nature Renewable energy Reliable and efficient use of the power of nature Solutions for electrical safety Electrical safety for efficient use of renewable energy Making efficient and reliable use of natural energy

More information

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances _D00108_00_D_XXEN/05.2015 ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances

More information

VARIMETER. Residual current monitor (RCM) Insulation monitoring device (IMD) Insulation fault detection system (EDS) Our experience. Your safety.

VARIMETER. Residual current monitor (RCM) Insulation monitoring device (IMD) Insulation fault detection system (EDS) Our experience. Your safety. VARIMETER Residual current monitor (RCM) Insulation monitoring device (IMD) Insulation fault detection system (EDS) Our experience. Your safety. Residual current and insulation monitoring Maximum availability,

More information

Ground fault protection Photovoltaic systems

Ground fault protection Photovoltaic systems T M Ground fault protection Photovoltaic systems Brochure NAE1111045 / 07.2016 2 2016 NEC Energy Solutions, Inc. - Used with Permission ENHANCED SAFETY SOLUTIONS For solar arrays, from the leader in electrical

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-259 Insulation fault locator Insulation fault locator for DC IT systems with high system leakage capacitances

More information

Product overview. Residual current monitoring. AC, pulsed DC and AC/DC sensitive residual current monitors RCM, RCMA, RCMB

Product overview. Residual current monitoring. AC, pulsed DC and AC/DC sensitive residual current monitors RCM, RCMA, RCMB Product overview Residual current monitoring AC, pulsed DC and AC/DC sensitive residual current monitors RCM, RCMA, RCMB Multi-channel, AC, pulsed DC and AC/DC sensitive residual current monitoring systems

More information

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems T M 1 isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE1012110 / 12.2011 isolr275 / AGH-LR Ground Fault Monitor

More information

Product overview Residual current monitoring

Product overview Residual current monitoring 4 Product overview Residual current monitoring AC, pulsed DC and AC/DC sensitive residual current monitors RCM, RCMA Multi-channel, AC, pulsed DC and AC/DC sensitive residual current monitoring systems

More information

ISOMETER iso685- Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER iso685- Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) iso685-x_d00022_08_d_xxen/04.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product

More information

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 0640 807-0 Fax: 0640 807-259 IT system floor-standing distribution cabinet Series -IPS-F/EDS for supplying power to medical locations

More information

ISOMETER iso685-d-p. Device features

ISOMETER iso685-d-p. Device features ISOMETER iso6- -P Insulation monitoring device with integrated locating current injector for IT AC systems with galvanically connected rectifiers or converters and for IT DC systems iso6-x-p_d D_XXEN/.

More information

ISOMETER iso685- -B. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet

ISOMETER iso685- -B. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet iso685-x-b_d00177_04_d_xxen/04.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems

More information

ISOMETER IR Headline. Version V004. Vorläufiges Datenblatt

ISOMETER IR Headline. Version V004. Vorläufiges Datenblatt Headline ISOMETER IR155-4210 Sub-Headline Insulation monitoring device (IMD) for unearthed charging systems (IT systems), for e.g. electric vehicles Version V004 Vorläufiges Datenblatt TDB106035en / 06.2012

More information

ISOMETER Headline IR /IR

ISOMETER Headline IR /IR ISOMETER Headline IR155-323/IR155-324 Insulation Sub-Headline monitoring device (IMD) for unearthed DC drive systems (IT systems) in electric vehicles Version V4 Vorläufiges Datenblatt IR155-32xx-V4_D115_2_D_XXEN/9.216

More information

A-ISOMETER IR / IR

A-ISOMETER IR / IR 1 Headline A-ISOMETER IR155-4203 / IR155-4204 Sub-Headline Insulation monitoring device (IMD) for unearthed DC drive systems (IT systems) in electric vehicles Preliminary data sheet Vorläufiges Datenblatt

More information

RCMS460 and RCMS490 Series

RCMS460 and RCMS490 Series 4 T M RCMS460 and RCMS490 Series Digital Multi-Channel Ground Fault Monitor / Ground Fault Relay Grounded and High-Resistance Grounded AC/DC Systems Technical Bulletin NAE1042060 / 04.2013 BENDER Inc.

More information

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300 Monitoring Technique VARIMETER IMD Insulation monitor RN 5897/300 0274214 Your Advantages For mobile generator sets according to DIN VDE 0100-551 Preventive fire and system protection Detection of symmetric

More information

EDS3090. Portable equipment for insulation fault location for energised and deenergised AC and DC systems Software version: D399 V2.

EDS3090. Portable equipment for insulation fault location for energised and deenergised AC and DC systems Software version: D399 V2. ESC OK EN Manual EDS3090 91, 92, 96 ISOSCAN EDS195P I n I s ALARM I n I s HOLD INFO RESET MENU Portable equipment for insulation fault location for energised and deenergised AC and DC systems Software

More information

Technical data Insulation fault location system Device components

Technical data Insulation fault location system Device components Technical data Insulation fault location system Device components Device type DS470-12 PRC470 Insulation coordination acc. to IC 60664-1: Rated insulation voltage AC 250 V AC 250 V AC 500 V Rated impulse

More information

Insulating fault locator to locate insulation faults in ungrounded DC, AC and three-phase power supplies (IT systems)

Insulating fault locator to locate insulation faults in ungrounded DC, AC and three-phase power supplies (IT systems) EN Manual EDS44 /44 Insulating fault locator to locate insulation faults in ungrounded DC, AC and three-phase power supplies (IT systems) EDS44 _D M_XXEN/4. PLEASE READ THIS MANUAL AND ANY ACCOMPANYING

More information

Installation / Monitoring Technique

Installation / Monitoring Technique Installation / Monitoring Technique VARIMETER RCM Residual Current Monitor, Type B for AC and DC Systems IP 5883 0249633 IP 5883 ND 5018/035 ND 5018/030 According to IEC/EN 62 020, VDE 0663 For AC and

More information

Insulation Guard IW 1000 Monitoring of ungrounded AC- and DC voltage systems up to 690V

Insulation Guard IW 1000 Monitoring of ungrounded AC- and DC voltage systems up to 690V Insulation Guard IW 0 Monitoring of ungrounded AC- and DC voltage systems up to 690V Features M Time optimized pulse measuring method M Safe monitoring at extreme conditions (frequency converter, phase

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

Measuring current transformers of the W, W series

Measuring current transformers of the W, W series Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000

More information

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/020

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/020 Monitoring Technique VARIMETER IMD Insulation monitor RN 5897/020 0277078 RN 5897/020 RP 5898 Product Description The insulation monitor RN 5897/020 of the VARIMETER IMD family provides best and up to

More information

Smart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC)

Smart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC) Smart Energy & Power Quality Solutions UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC) UMG 96RM UMG 96RM Universal measurement instrument Unrivalled in its class The UMG 96RM is a

More information

A6500-UM Universal Measurement Card

A6500-UM Universal Measurement Card Specifications Sheet A6500-UM Universal Measurement Card The A6500-UM Universal Measurement Card is a component of the CSI 6500 ATG machinery protection system. The card is equipped with 2 sensor input

More information

Power Quality and Energy Measurement PEM735

Power Quality and Energy Measurement PEM735 Power Quality and Energy Measurement PEM75 PEM75_D00084_01_D_XXEN/01.2015 Power Quality and Energy Measurement PEM75 class A Product description The digital universal measuring device PEM75 is suited for

More information

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I Memory 256 MB Alarm management Residual current measurement Homepage Ethernet-Modbus gateway BACnet (optional) UMG 96 RM-E Power analyser with Ethernet and RCM Communication Modbus (RTU, TCP, Gateway)

More information

UMG 509-PRO. Multifunction power analyser with RCM

UMG 509-PRO. Multifunction power analyser with RCM UMG 509-PRO Multifunction power analyser with RCM Power quality RCM Residual current monitoring Ethernet connection Ethernet-Modbus gateway Graphic programming Alarm management Communication Profibus (DP/V0)

More information

Sunways Solar Inverters NT 2500, NT 3000, NT 3700, NT 4200 and NT 5000 AC output: 2.5 to 5.0 kw

Sunways Solar Inverters NT 2500, NT 3000, NT 3700, NT 4200 and NT 5000 AC output: 2.5 to 5.0 kw Sunways Solar Inverters NT 2500, NT 3000, NT 3700, NT 4200 and NT 5000 AC output: 2.5 to 5.0 kw The tried and tested NT series has been completely reengineered and impresses with further improved performance

More information

Installation- / Monitoring Technique

Installation- / Monitoring Technique Installation- / Monitoring Technique VARIMETER Insulation fault locator RR 5887 0269248 Product Description 4-channel design The locating current generator RR 5886 in connection with the insulation fault

More information

Remote I/O. 74 Remote I/O. Remote I/O System

Remote I/O. 74 Remote I/O. Remote I/O System System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU

More information

Power Quality and Energy Measurement PEM533

Power Quality and Energy Measurement PEM533 Power Quality and Energy Measurement _D00013_02_D_XXEN/11.2014 Power Quality and Energy Measurement 0.5 S Product description The digital universal measuring device is suited for measuring and displaying

More information

ISOLGUARD R. overview catalogue. insulation monitoring device. Insulation Monitoring Device

ISOLGUARD R. overview catalogue. insulation monitoring device. Insulation Monitoring Device overview catalogue Insulation Monitoring Device Hakel is a dynamic company which since foundation in 1994 has quickly developed in terms of turnover and the product assortment. This dynamism can also be

More information

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality

More information

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM Power quality Colour graphical display Ethernet connection Ethernet-Modbus gateway Graphic programming Alarm management UMG 508 Multifunction power analyser Communication Profibus (DP/V0) Modbus (RTU,

More information

QUINT-PS/ 3AC/24DC/10

QUINT-PS/ 3AC/24DC/10 Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 Description PHOENIX CONTACT - 09/2009 Features QUINT POWER power supply units Maximum system

More information

Safety through Competence. Short Form Catalogue. Measuring Testing Controlling World Class Hardware and Software

Safety through Competence. Short Form Catalogue. Measuring Testing Controlling World Class Hardware and Software Safety through Competence Short Form Catalogue Measuring Testing Controlling World Class Hardware and Software MAVOLOG 20P Test Instrument for Monitoring Voltage Quality Electrical Engineering, Maintenance,

More information

PHOENIX CONTACT - 09/2009

PHOENIX CONTACT - 09/2009 Electronic miniature circuit-breaker CLIPLINE Data sheet 03906_en_0 PHOENIX CONTACT - 09/2009 Description The EC-E... electronic miniature circuit-breaker selectively protects all 24 V DC load circuits

More information

Why the IT system is often the best choice for power supply systems of all types

Why the IT system is often the best choice for power supply systems of all types Why the IT system is often the best choice for power supply systems of all types Let us start initially with a clear commitment: the IT system ("unearthed system") is a type of system infrequently used

More information

Power Quality and Energy Measurement PEM575

Power Quality and Energy Measurement PEM575 Power Quality and Energy Measurement _D00016_00_D_XXEN/06.2013 Power Quality and Energy Measurement Product description The digital universal measuring device is suited for measuring and displaying electrical

More information

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New) XR1 Rotor Earth Fault Relay (May 2007) Manual XR1 (Revision New) Woodward Manual XR1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided

More information

Power Quality and Energy Measurement PEM575

Power Quality and Energy Measurement PEM575 Power Quality and Energy Measurement _D00016_03_D_XXEN/12.2015 Power Quality and Energy Measurement Product description The digital universal measuring device is suited for measuring and displaying electrical

More information

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung Dimension diagrams All dimensions in mm 73 mm 10 mm 35 mm 44 mm 90 mm 90 mm 107,5 mm 50 mm 76 mm 82 mm Front view Side view Typical connection An. In R32 RS485 Dig. I/O Versorgungsspannung Auxiliary Supply

More information

Power Quality Solutions PQSine P-Series of Active Harmonic Filters and Power Optimizers

Power Quality Solutions PQSine P-Series of Active Harmonic Filters and Power Optimizers EPCOS Product Brief 2017 Power Quality Solutions of Active Harmonic Filters and Power Optimizers EPCOS has been offering a comprehensive range of key components for power factor correction (PFC) and power

More information

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test A new standard for Hipot & Insulation resistance testing Applied to World-Wide input voltage TOS5301 TOS5300 TOS5302 TOS5300(ACW) TOS5301(ACW/DCW) TOS5302(ACW/IR) New low-cost standard model that provides

More information

The Power in. Electrical Safety. Product presentation isohr685w-d/s-i-b. Updated: BENDER > isohr685 Mumtaz Farooqi

The Power in. Electrical Safety. Product presentation isohr685w-d/s-i-b. Updated: BENDER > isohr685 Mumtaz Farooqi The Power in Electrical Safety Product presentation isohr685w-d/s-i-b 1 Updated: 04.03.2015 isohr685 content 1. IT systems and IMD 2. isohr685 3. Summary 2 IT system and Insulation Monitoring Device An

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

Comm Series DC Power Supplies Radio Base Station Covers Battery Chargers DC UPS Backup Systems

Comm Series DC Power Supplies Radio Base Station Covers Battery Chargers DC UPS Backup Systems Product Catalog 2014 Condensed Version INNOVATIVE CIRCUIT TECHNOLOGY LTD. ICT has been providing DC power conversion products since 1986 for two-way wireless communications, fixed wireless broadband and

More information

This data sheet is only valid in association with the IL SYS INST UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual. Inline counter terminal, version for extreme conditions, 1 counter input, 1 control input, 1 output, 24 V DC, 500 ma Data sheet 106148_en_03 PHOENIX CONTACT 2015-11-04 1 Description The terminal is designed

More information

Operating Instruction

Operating Instruction Level and Pressure Operating Instruction VEGASEL 643 6 5 + + 3 5 + + max. min. on VEGASEL 643 5 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 1 Product description 1.1 Function

More information

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C) XR1 Rotor Earth Fault Relay Manual XR1 (Revision C) Woodward Manual XR1 (EN) Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

QUINT-PS AC/24DC/40

QUINT-PS AC/24DC/40 Power supply unit INTERFACE Data sheet 102315_en_02 1 Description PHOENIX CONTACT 2010-04-23 Features QUINT POWER power supply units for plant and special engineering reliably start heavy loads with high

More information

Operating instructions Fail-safe delay timer AZS About this document. Content

Operating instructions Fail-safe delay timer AZS About this document. Content 8 Appendix 8.1 Wiring example...4 8.2 Integral System Diagnostics (ISD)....5 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101126753-

More information

CM-IWM.11 Insulation monitoring relay

CM-IWM.11 Insulation monitoring relay Data sheet CM-IWM.11 Insulation monitoring relay The insulation monitor CM-IWM.11 provides best and up to date insulation monitoring of modern IT systems in an optimum and state of the art way fulfilling

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

LEAK CURRENT HiTESTER ST5540/ST Washington Street Melrose, MA Phone Toll Free

LEAK CURRENT HiTESTER ST5540/ST Washington Street Melrose, MA Phone Toll Free LEAK CURRENT HiTESTER ST5540/ST5541 Safety measuring instruments 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Leak Current Measurement

More information

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I Harmonics Temperature input Measurement accuracy 0.5 Memory 4 MByte UMG 104 Energy measurement device for DIN rails Communication Profibus (DP / V0 optional) Modbus RTU Power quality Harmonics up to 40th

More information

The wireless alternative to expensive cabling...

The wireless alternative to expensive cabling... The wireless alternative to expensive cabling... ELPRO 105U ISO 9001 Certified New Products... New Solutions The ELPRO 105 range of telemetry modules provide remote monitoring and control by radio or twisted-pair

More information

The wireless alternative to expensive cabling...

The wireless alternative to expensive cabling... The wireless alternative to expensive cabling... ELPRO 105U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 105U range of wireless I/O provides a low cost alternative

More information

Smart Power Relay E I...

Smart Power Relay E I... Smart Power Relay E-48-8I... Description The Smart Power Relay E-48-8I.- is a remotely controllable electronic load disconnecting relay with three functions in a single unit: l electronic relay l electronic

More information

Electronic circuit breaker ESS30-Sxxx-DC24V

Electronic circuit breaker ESS30-Sxxx-DC24V Electronic circuit breaker ESS30-Sxxx-DC2V Description The electronic circuit protector ESS30-S with physical isolation is the globally unique electronic over protection for DC 2 V applications as a low

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

PEM353. Universal measuring device

PEM353. Universal measuring device 353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities

More information

SINEAX B 811 Power Pack with additional Functions

SINEAX B 811 Power Pack with additional Functions SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers

More information

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS INSTRUCTION MANUAL BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS 1/23 More information than that reported

More information

Side view View from below Rear view

Side view View from below Rear view Dimension diagrams All dimensions in mm Side view View from below Rear view Cut out: 138 +0,8 x 138 +0,8 mm Typical connection SPS SPS 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 DSUB-9 5 4 3 2 1 8 7 6 5 4

More information

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INSTRUCTIONS MANUAL IM831-U v0.92 HRI-R40W sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INDEX: GENERAL TYPES ACESSORIES AND OPTIONS

More information

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready / Battery Charging Systems / Welding Technology / Solar Electronics FRONIUS SYMO / Maximum flexibility for the applications of tomorrow. / PC board replacement process / Mounting system / WLAN interface

More information

M.3. Electrical measurement and control. Electrical energy meters for partial consumption

M.3. Electrical measurement and control. Electrical energy meters for partial consumption M.3 Electrical measurement and control Electrical energy meters for partial consumption M.3 Electrical energy meters for partial consumption M.3 - Electrical energy meters for partial consumption Introduction

More information

Partial Discharge, Survey or Monitor?

Partial Discharge, Survey or Monitor? July 2014 Partial Discharge, Survey or Monitor? 24-7 Partial Discharge monitoring is the ultimate tool for finding insulation weaknesses before they fail. Introduction It s well established that Partial

More information

Insulation Monitoring Relays CM range

Insulation Monitoring Relays CM range Insulation Monitoring Relays CM range ABB s insulation monitoring relays CM range generator side converter line side converter DC 10... 24 kv, f = 50 Hz or 60 Hz line coupling transformer converter control

More information

QUINT-PS/ 3AC/24DC/40

QUINT-PS/ 3AC/24DC/40 Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum

More information

QUINT-PS/ 1AC/24DC/20

QUINT-PS/ 1AC/24DC/20 Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data sheet 103129_en_04 1 Description PHOENIX CONTACT - 02/2010 Features QUINT POWER power supply units Maximum system

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

V P N. Voltage transducer DVM 4200 = 4200 V

V P N. Voltage transducer DVM 4200 = 4200 V Voltage transducer DVM 42 N = 42 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated measurement

More information

Power Quality Solutions

Power Quality Solutions Power Quality Solutions What is Power Quality? For electrical systems to function in their intended manner without significant loss of performance or life, they require a supply of electricity that is

More information

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Original operating instructions Fail-safe inductive sensor GM504S / / 2010 Original operating instructions Fail-safe inductive sensor GM504S 704070 / 01 06 / 2010 Contents 1 Preliminary note 3 1.1 Explanation of symbols 3 2 Safety instructions 4 2.1 Safety-related requirements

More information

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No Portable Appliance Testers OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver. 1.2. Code No. 20 750 684 Distributor: Producer: METREL d.d. Ljubljanska 77 SI-1354 Horjul E-mail: metrel@metrel.si http://www.metrel.si

More information

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions Operating Instructions SIMEAS-T s Operating Instructions Transducer without auxiliary power for alternating current for alternating voltage for alternating voltage with expanded end range 7KG6111 and 7KG6101

More information

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents I. Overview...2 II. Open-case Inspection...3 III. Safety Precautions...4 IV. Work Principle...7 V. Appearance Description...9 VI. Technical Characteristics 10 VII. Resistance Measurement Method..12 VIII.Battery

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions ELECTRONIC SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING

More information

MINI-PS AC/2X15DC/1

MINI-PS AC/2X15DC/1 MII-PS-100-240AC/2X15DC/1 Power supply unit ITERFACE Data sheet 100299_en_04 1 Description PHOEIX COTACT - 2010-10-20 Features MII POWER is the extremely slim power supply unit with constructional widths

More information

Protection Relays. U-MLEs-PLs-Ts. Ultra-Ts. DC SUBSTATION PROTECTIVE RELAY (single voltage Line Test) 32, 45, 49, 64, 76, 79, 80

Protection Relays. U-MLEs-PLs-Ts. Ultra-Ts. DC SUBSTATION PROTECTIVE RELAY (single voltage Line Test) 32, 45, 49, 64, 76, 79, 80 Ultra-Ts DC SUBSTATION PROTECTIVE RELAY (single voltage Line Test) 32, 45, 49, 64, 76, 79, 80 D.C. Feeder protection relay with setting parameters programmable locally or via serial communication. Suitable

More information

GOSSEN METRAWATT. Testers

GOSSEN METRAWATT. Testers Testers 45 Testers Protective measures in electrical systems are intended to prevent bodily injury due to accidents involving electrical current. Of course they also prevent property damage caused by electrical

More information

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality

More information

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation Excitation Systems Compound-Excitation System for Synchronous Generators Power Generation Operating Characteristics Load dependent Short circuit supporting Low voltage gradient dv/dt Black start capability

More information

Switching Devices Contactors and Contactor Assemblies for Switching Motors

Switching Devices Contactors and Contactor Assemblies for Switching Motors Switching Devices Contactors and Contactor Assemblies for Switching Motors groups 41B, 41H / Introduction Power contactors for switching motors /5 General data /11 SIRIUS RT10 contactors, -pole,... 50

More information

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide 12/03/2012 V11.0 P.O.Box 164 Seven Hills 1730 NSW AUSTRALIA Tel: +61 2 96248376 Fax: +61 2 9620 8709 Email: proconel@proconel.com Web: www.proconel.com

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

V P N. Voltage transducer DVM 2000-B = 2000 V

V P N. Voltage transducer DVM 2000-B = 2000 V Voltage transducer DVM 2-B V P N = 2 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information