SINEAX B 811 Power Pack with additional Functions

Size: px
Start display at page:

Download "SINEAX B 811 Power Pack with additional Functions"

Transcription

1 SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers the measured variable unchanged to the electrically insulated output. Conversion to a different signal range such as 0 to 5 ma or to 5 V (signal converter) is also possible. Some versions of the SINEA B 8 are designed for communication. They are used in conjunction with intelligent s which are capable of dialogue and operation according to the principle and the HART or user-specific protocol. The series also includes intrinsically safe versions [EEx ia] IIC with an intrinsically safe measurement/supply circuit. These operate in conjunction with intrinsically safe s located in explosion hazard areas. Provision is made for monitoring the measurement/supply circuit to detect short and open-circuits. Either of these faults is signalled by the fault signalling relay and the red LED. The output signals A and A2 can be set on the DIP switches to have a linear increasing or decreasing response. The instrument fulfils all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (IEC 00 resp. EN 6 00). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO 900. Production QA is also certified according to guideline 94/9/EG. Fig.. SINEA B 8 in housing S7. Output can be switched between 0 to 20 ma and 4 to 20 ma / Universal matching to suit downstream device Green power on LED Compact and narrow Technical data Features / Benefits Designed for communication, hand-held terminal connected to separate terminals. This facilitates operation in conjunction with an intelligent designed for and with a HART or user-specific protocol Electrically insulated between input circuit, output and power supply / Fulfils IEC 00 resp. EN 6 00 part 2 AC/DC power supply / Universal Intrinsically safe version [EEx ia] IIC available (see Table 5 Explosion protection data ) Measurement/supply circuit monitored for open and short-circuits / Faults signalled by red LED, signalling relay and/or device failure signal (MSK) Signal range I E Supply voltage (at I E = 20 ma) 4 to 20 ma DC 24 V ± 7% with standard (non-ex) version, not designed for communications protocol 24 V ± 7% with standard (non-ex) version, designed for communication > 6.9 V with Ex versions not designed for communications protocol > 6.4 V with Ex versions designed for communication = Frequency Shift Keying Camille Bauer Data sheet B8- Le 07.07

2 SINEA B8 Current limiter Max. line resistance Electronic At I E > 30 ma, is switched to 0 V for approx. s. is then automatically readjusted to its set-point The maximum line resistance R Line permissible between the and the supply unit depends on the voltage difference U M R Line max. = U M 20 ma = Supply voltage for U M = Min. operating voltage of the If the load of the burden across output A already exceeds 250 Ω, the resistor can be disconnected by changing the position of a jumper. The full burden voltage of 5 V is then available at output A instead of 0 V. External resistance I A R ext max. [kω] = Burden voltage I A2 5 V (0 V) I AN [ma] I AN = Output circuit full-scale value < 0.3 V (field indicator) External resistance I A2 R ext max. [kω] = Residual ripple Response time (IEC 770) Output characteristic 0.3 V I AN [ma] < % p.p., DC to 0 khz Approx. 200 ms Linear Measuring output Output signals A and A2 (see section Electrical connections ) The output signals A and A2 can be load-independent DC voltages U A or currents I A. A and A2 are not electrically insulated; the same value is available at both outputs. DC voltage signals U A Standard ranges for U A Non-standard ranges Short-circuit current Load-capacity U A /U A2 Load impedance U A /U A2 Residual ripple DC current signals I A Standard ranges for I A Non-standard ranges Open-circuit voltage Burden voltage I A 0 to 5, to 5, 0 to 0 or 2 to 0 V 0 to > 5 to 0 to 5 V resp. live-zero > ( to 5) to 3 to 5 V 40 ma 20 ma R ext A // R ext A2 [kω] < % p.p., DC to 0 khz 0 to 20 ma or 4 to 20 ma selected by jumpers 0 to to 0 to < 20 ma resp. live-zero 0.2 to to < (4 to 20) ma Approx. 7 to 22 V U A [V] 20 ma 5 V without communication 0 V (5 V) with communication* *When a hand-held terminal is connected to the field output A2, the voltage across the burden at output A reduces to 0 V. Digital communication requires a minimum burden at output A of 250 Ω. A 250 Ω resistor is therefore connected across the output circuit. Power supply H AC/DC power pack (DC and 45 to 400 Hz) Table Nominal voltages and tolerances Nominal voltage Tolerance U N 24 to 60 V DC / AC DC 5 to 33% 85 to 230 V AC ± 5% DC / AC 24 to 60 V DC / AC 85 to 230 V AC 85 to 0 V DC DC 5 to 33% AC ± 5% ± 0% 5 to 0% Standard (non-ex) Instrument version Type of protection Intrinsically safe [EEx ia] IIC For power supplies > 25 V, the auxiliary circuit should include an external fuse with a rating 20 A DC. Power input Communication Approx. 2.5 W resp. 4.5 VA Bi-directional communication of digital signals with an intelligent designed for and a HART or companyspecific protocol. Frequency range monitor Pick-up level 500 Hz to 35 khz Open-circuit Input current < 3.6 ma, adjustable in the works between and 4 ma Short-circuit Input current > 2 ma adjustable in the works between 20 and 23 ma 2 Data sheet B8- Le Camille Bauer

3 SINEA B8 Signalling modes Output signals A and A2 Frontplate signals Output contact Table 2 Type of output contact Symbol Material Gold flashed silver alloy Relay approved by UL, CSA, TÜV, SEV Direction of action Accuracy data (acc. to DIN/IEC 770) Output signal linear response For an open-circuit output 0 ma (with 4 to 20 ma) 5 ma (with 0 to 20 ma) For a short-circuit output approx. 26 ma Increasing output signal Output approx. 5% of fullscale value, e.g. 23 ma for output 0/4 to 20 ma or.5 V for output 0/2 to 0 V Decreasing output signal (only possible for live zero) Output approx. 0% of full-scale value, e.g. 2 ma for output 4 to 20 ma or V for output 2 to 0 V Failure signalled by red LED relay, potentially-free changeover contact (see Table 2) Contact rating AC 2 A / 250 V (500 VA) DC A / V (30 W) Adjustable by switch Relay energized or de-energized in the case of a failure Basic accuracy Limit erreur ± 0.2% Including linearity and reproducibility errors Burden influence Long-time drift Switch-on drift < ± 0.2% Common and transverse mode influence < ± 0.2% Output or connected to ground < ± 0.2% Regulations Electromagnetic compatibility < ± 0.% with current output < 0.2% with voltage output, if R ext > 2 R ext min. < ± 0.3% / 2 months The standards DIN EN and DIN EN are observed Intrinsically safe Acc. to DIN EN Electrical standards Acc. to IEC 00 resp. EN 6 00 Protection (acc. to IEC 529 resp. EN ) Housing IP 40 Terminals IP 20 Operating voltages Contamination level 2 Overvoltage category acc. to IEC 664 Double insulation Test voltage <300 V between all insulated circuits III for power supply II for measuring input, measuring output and output contact Power supply versus all other circuits, Measuring input versus measuring output and output contact Measuring output versus output contact Power supply versus measuring input, measuring output and output contact 3.7 kv, 50 Hz, min. Measuring input versus measuring output 2.3 kv, 50 Hz, min. Measuring output versus output contact 2.3 kv, 50 Hz, min. Reference conditions Ambient temperature Power supply Output burden Influencing factors Temperature 23 C, ± 2 K 24 V DC ± 0% and 230 V AC ± 0% Current 0.5 R ext max. Voltage 2 R ext min. < ± 0.% per 0 K Environmental conditions Commissioning temperature 0 to 55 C Operating temperature 25 to 55 C, Ex 20 to 55 C Storage temperature 40 to 70 C Annual mean relative humidity Vibration (IEC 68 T2/6) 75% standard climatic rating 95% enhanced climatic rating 2 g / 5 to 50 to 5 Hz; octave/min., 2 h Camille Bauer Data sheet B8- Le

4 SINEA B8 Shock (IEC 68 T2/27) Altitude Indoor use statement! Installation data Housing Material of housing 30 g / ms 2000 m max. Housing S7 See section Dimensional drawings for dimensions Lexan 940 (polycarbonate) flammability class V-0 acc. to UL 94, self-extinguishing, nondripping, free of halogen Mounting Position of use For snapping onto top-hat rail (35 x 5 mm or 35 x 7,5 mm) acc. to EN or directly onto a wall or panel using the pull-out screw hole brackets Any Terminals DIN/VDE 0609 Screw terminals with wire guards, for light PVC wiring and max. 2 x 0.75 mm 2 or x 2.5 mm 2 Weight Approx. 0.2 kg Standard version When ordering, it is only necessary to quote the Order No. Table 3 Instrument in version [EEx ia] IIC, (input circuit intrinsically safe) Version Order Code Order No. Supply voltage 6.9 V DC at 20 ma Power supply 85 to 0 V DC / 230 V AC Outputs A and A2* 4 to 20 ma, R ext 750 Ω (field communications protocol) Not designed for communications protocol fault detection Open-circuit < 3.6 ma, short-circuit > 2 ma Response to an input circuit Output signal linear response Response of the output contact for a measurement/supply circuit fault Without relay, without output contact Climatic rating Standard climatic rating 8-4B The complete order code according to Table 4 Specification and ordering information should be stated for other versions. * 2nd output signal A2 for field indicator only Table 4 Specification and ordering information (see also Table 3 Standard versions ) Description *Blocking code No-go with blocking code Article No./ Feature SINEA B8- Order Code 8-xxxx xxxx 8 Features, Selection. Mechanical design Housing S7 2. Version / Power supply H (nominal voltage U N ) Standard / 24 to 60 V DC/AC Standard / 85 to 230 V DC/AC 2 [EEx ia] IIC MSK intrinsically safe / 24 to 60 V DC/AC 3 [EEx ia] IIC MSK intrinsically safe / 85 to 0 V DC, 85 to 230 V AC 4 Lines 3 and 4 Instrument [EEx ia] IIC, input circuit (MSK) EEx ia IIC 4 Data sheet B8- Le Camille Bauer

5 SINEA B8 Description *Blocking code No-go with blocking code Article No./ Feature SINEA B8- Order Code 8-xxxx xxxx 8 Features, Selection 3. Output signals / measuring outputs A and A2** 0 to 5 V, R ext 250 Ω CD to 5 V, R ext 250 Ω C 2 0 to 0 V, R ext 500 Ω CD 3 2 to 0 V, R ext 500 Ω C 4 Non-standard [V] 0 to > 5 to 0 to 5 [V] CD 8 Live zero [V] > ( to 5) bis 3 to 5 [V] C 9 0 to 20 ma, R ext 750 Ω (500 Ω)*** DE A 4 to 20 ma, R ext 750 Ω (500 Ω)*** B Non-standard [ma] 0 to to 0 to < 20 [ma] CD Y Live zero [ma] 0.2 to to < (4 to 20) [ma] C Z 4. (field communications protocol) Not designed for communications protocol 0 Designed for communication, at field output A2 C ( 0 to 20 / 4 to 20 ma) Designed for communication, at measuring output A CE 2 ( 4 to 20 ma only) 5. fault detection Open / short-circuit detection Open-circuit < 3.6 ma; short-circuit > 2 ma 0 Open-circuit; short-circuit [ma] Open-circuit Values from to 4 ma Short-circuit Values from 20 to 23 ma e.g. [ma] 2;22 6. Response to an input circuit Output signal linear response 0 Increasing output signal >>> (Output approx. 5% of full-scale) Decreasing output signal <<< D 2 (Output approx. 0% of full-scale, with live zero signal only) 7. Response of the output contact for a measurement/supply circuit fault Without output contact 0 Output contact relay energized Output contact relay de-energized 2 8. Climatic rating Standard climatic rating 0 Improved climatic rating * Lines with letter(s) under No-go with blocking code cannot be combined with preceding lines having the same letter under Blocking code. ** A2 according to instrument version for connection with a field indicator or hand-held terminal only *** External resistance dependent on the position of jumper J 204 / J 205, see section technical data Measuring output Camille Bauer Data sheet B8- Le

6 SINEA B8 Table 5 Explosion protection data II () G Order code Type of protection [EEx ia] IIC Measuring circuit input U o = 2 V I o = 75 ma P o = 660 mw Trapezium characteristic IIC IIB L o 6.7 mh 25 mh C o 78 nf.26 µf Output, Power supply relays contacts U m = 253 V AC resp. 25 V DC Certificates PTB 97 ATE 2083 Mounting location Outside the hazardous area Electrical connections MSK Front GOSSEN METRAWATT SINEA B8 Space e.g. for MSK designation ON ON Green power on LED Red LED open and short-circuit monitor of input circuit MSK 4 9 A 3 8 A Without transparent cover HHT With transparent cover Relay b a c N/O contact N/C contact a c b c 5 0 H MSK A A2 HHT H = (terminal allocation according to type, see Table 6 ) = Measuring output = 2nd measuring output (field indicator) voltage drop across field indicator or milliammeter 300 mv, resp. connection for handheld terminal = Output contact for monitoring the input circuit (fault signalling output) Refer to the figure relay for details = Hand-held terminal = Power supply 6 Data sheet B8- Le Camille Bauer

7 SINEA B8 Configuration. Switching output signals A and A2 between the signal ranges 0 to 20 ma or 4 to 20 ma The range of the outputs can be switched from 0 to 20 ma to 4 to 20 ma or vice versa depending on the positions of jumpers J 202 and J 203 (Fig. 2). Output signals A / A2 Position of jumpers J 202 J to 20 ma 0 to 20 ma Communication connector Connect the communication connector to output A or A2 (Figures 5 to 8). Signals are then transferred in both directions between the hand-held terminal and the via the SINEA B 8. When using the field output A2, the 250 Ω burden connected across output A2 in the power supply unit can be switched in and out of circuit with the aid of jumpers J 204 and J 205 (Fig. 2). Communication connected to Field output A2* Integrated 250 Ω resistor in circuit The burden at measuring output A is reduced 250 Ω Choice of A output signal range 0/4 to 20 ma Voltage across A burden 0 V Field output A2* Integrated 250 Ω resistor not in circuit The burden at measuring output A is not reduced. A output signal range 4 to 20 ma only Voltage across A burden 5 V Measuring output A Output signal range 4 to 20 ma Voltage across A burden 5 V Position of jumpers J 204 J *See Measuring output in the Technical data section Fault Break Shortcircuit Output linear behaviour 0 ma ( 4 to 20 ma) 5 ma ( 0 to 20 ma) Approx. 26 ma 0/4 to 20 ma Output driving upscale Approx. 5% of full scale end value e.g. 23 ma 0/4 to 20 ma or.5 V 0/2 to 0 V Output driving downscale (with live-zero only) Approx. 0% of full scale end value e.g. 2 ma 4 to 20 ma or V 2 to 0 V 4. Response of the output contact for a fault in the measurement/supply circuit The response of the fault signalling relay can be set with the aid of switches 3 and 4 on the DIP switch S 20 (Fig. 2). Operating sense of the DIP switch S 20 fault signalling relay in the event of a fault Switch 3 Switch 4 Relay energised ON OFF Relay de-energised OFF ON ON OFF S J202 3 J203 3 J205 J Response of the output signals A and A2 for a fault in the measurement/supply circuit The response of the output signals A and A2 can be set with the aid of switches and 2 on the DIP switch S 20 (Fig. 2). Response of output signals A and A2 for a short or open-circuit of the measurement/supply circuit Dip switch S 20 Switch Switch 2 Linear output signal ON OFF Increasing output signal OFF OFF Decreasing output signal (only with live zero signal) OFF ON Fig. 2. Positions of the DIP switches S 20 and jumpers J 202 to J 205. Camille Bauer Data sheet B8- Le

8 SINEA B8 Table 6 Terminal allocation Hazardous area Connection of an HHT (terminals 2 and 7 connected directly to terminals and 6) Connection of an HHT (terminals 2 and 7 connected directly to terminals and 6) A A2 HHT A A2 *HHT Ex H ~ () ~ () H ~ () ~ () * Note data given in the conformity certificate. Fig. 3. SINEA Type , Non-Ex input and output circuits, supply voltage 24 V DC, not designed for. Fig. 4. SINEA Type , Intrinsically safe input circuit, supply voltage 6.9 V DC, not designed for. Hazardous area H ~ () ~ () A 0/ A2 HHT H ~ () ~ () A 0/ A2 HHT Fig. 5. SINEA Type , Non-Ex input and output circuits, supply voltage 24 V DC, designed for. Hand held terminal connected to field output A2. Fig. 6. SINEA Type , Intrinsically safe input circuit, supply voltage 6.4 V DC, designed for. Hand held terminal connected to field output A2. HHT = Hand-Held-Terminal Continuation of Table 6 Terminal allocation see on next page! 8 Data sheet B8- Le Camille Bauer

9 SINEA B8 Continuation Table 6 Terminal allocation Hazardous area A PLS/ SPS A PLS/ SPS A2 A2 H ~ () ~ () H ~ () ~ () Fig. 7. SINEA Type , Non-Ex input and output circuits, supply voltage 24 V DC, designed for. Processor connected to output A. Fig. 8. SINEA Type , Intrinsically safe input circuit, supply voltage 6.4 V DC, designed for. Processor connected to output A. Dimensional drawings 20 Standard accessories Operating Instructions in three languages German, French, English 2 Withdrawing handle (for opening the housing) 2 Labels (under transparent cover) Type examination certificate (only for Intrinsically safe explosion-proof devices) Fig. 9. SINEA B 8 in housing S7 clipped onto a top-hat rail (35 5 mm or mm, acc. to EN ) Ø4.5 Rely on us , Fig. 0. SINEA B 8 in housing S7 screw hole mounting brackets pulled out. Camille Bauer AG Aargauerstrasse 7 CH-560 Wohlen / Switzerland Phone Fax info@camillebauer.com Subject to change without notice Edition Data sheet B8- Le

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex for electrically insulating, amplifying and converting DC signals, also designed for FSK 1 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1) is to electrically insulate

More information

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output

More information

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar SINEAX TV 808, channels For electrically insulating, amplifying and converting DC signals Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. ) is to electrically insulate input and

More information

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically

More information

SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate

More information

SINEAX TV809, 1 channel Programmable Isolating Amplifier

SINEAX TV809, 1 channel Programmable Isolating Amplifier For electrically insulating, ampliflying and converting DC signals 0102 II (1) Ga II (1) Da Application The purpose of the isolating amplifi er SINEAX TV809 (Fig. 1) is to electrically insulate input and

More information

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar Fig. 1. Isolating amplifier RISH Ducer TV 808 in housing S 17 clipped onto a top - hat rail or screw hole mounting brackets pulled out. Features and Benefits Electric Isolation between input, and power

More information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.

More information

SINEAX U 553 Transducer for AC Voltage

SINEAX U 553 Transducer for AC Voltage With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U 55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load

More information

Plug-in module SIRAX TI 807 Passive DC signal isolator

Plug-in module SIRAX TI 807 Passive DC signal isolator without power supply, x- and non-x version 0102 II (1) resp. II (2) pplication The signal isolator SIRX TI 807 (Fig. 1) serves to electrically insulate the analogue DC signal in the range 0 20 m which

More information

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out. Technical Data Sheet Theta 60R 60 R 60 R Fig. Theta R, channel version, in housing S7 clipped on to a top - hat rail. Fig. Theta R, channel version, in housing S7 hole mounting brackets pulled out. Theta

More information

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage Application The transducers SINEAX I 503/U 504 (Figs. 1 and 2) are designed to convert a sinusoidal AC current or voltage into a load independent DC signal proportional to the measured value. This output

More information

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar for electrically insulating, amplifying and converting DC signals 0102 II (1) G pplication The purpose of the isolating amplifi er SIRX T 808 (Fig. 1) is to electrically insulate input and output signals,

More information

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs Plug-in module, or channels Application The programmable transmitter (Fig. ) is designed for measuring temperature in combination with thermocouples or resistance thermometers. Thermocouple non-linearities

More information

SINEAX I 552 Transducer for AC current

SINEAX I 552 Transducer for AC current SNEAX 55 With power supply RMS value measurement, with measuring ranges Carrying rail housing P/0 Application he transducer SNEAX 55 (Fig. ) converts a sinusoidal or a distorted AC current into a load

More information

SINEAX G 536 Phase Angle or Power Factor Transducer

SINEAX G 536 Phase Angle or Power Factor Transducer SIEAX G Carrying rail housing P/0 Application The transducer SIEAX G (Fig. ) measures the phase angle or power factor between current and voltage of a single or -phase balanced network having a sine wave

More information

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits SINEAX VC 603, Programmable for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The SINEAX VC 603 (Figs. 1 and 2) converts the input variable a

More information

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex for electrically insulating, amplifying and converting DC signals, also designed for FSK 002 II () G pplication The purpose of the isolating amplifi er SIRX TV 808 (Fig. ) is to electrically insulate input

More information

SINEAX G 537 Transducer for Phase Angle Difference

SINEAX G 537 Transducer for Phase Angle Difference Carrying rail housing P/0 pplication The transducer SINX G 5 (Fig. ) converts the phase angle difference of two synchronised supplies into a load independent DC current or a load independent DC voltage

More information

SINEAX V 604 Programmable universal transmitter

SINEAX V 604 Programmable universal transmitter for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The universal transmitter SINEAX V 604 (Figures 1 and 2) converts the input variable a DC current

More information

SINEAX / EURAX 2I1 Passive DC signal isolator

SINEAX / EURAX 2I1 Passive DC signal isolator SINEAX / EURAX I without power supply 0 II () G resp. II () G Application The DC signal isolator SINEAX/EURAX I (Figs. and ) serve to isolate load-independent DC current signals. It suppressed noise voltages

More information

KINAX 2W2 Programmable Transmitter for Angular Position

KINAX 2W2 Programmable Transmitter for Angular Position Application The KINAX 2W2 (Figs. 2 and 3) converts the angular position of a shaft into a load independent direct current signal, proportional to the angular position. The unit is contact free and has

More information

KINAX WT 717 Programmable Transmitter for Angular Position

KINAX WT 717 Programmable Transmitter for Angular Position Ruggedized version Application The KINAX WT 717 (Fig. 1) converts the angular position of a shaft into a load-independent direct current signal, proportional to the angular position. The unit is contact

More information

KINAX SR 719 Programmable Transmitter for Position Feedback

KINAX SR 719 Programmable Transmitter for Position Feedback Position transmitter with NAMUR valve fitting Application The position feedback transmitter KINAX SR 719 (Figs. 1 and 2) is used to measure and transmit linear displacement (stroke) on various types of

More information

EMBSIN 281 G Power factor transducer

EMBSIN 281 G Power factor transducer EMBSI 8 G Carrying rail housing MBS/SP Application The transducer EMBSI 8 G (Fig. ) measures the power factor between current and voltage of a single or 3-phase balanced network having a sine wave form.

More information

SINEAX V 604s Programmable multifunctional transmitter

SINEAX V 604s Programmable multifunctional transmitter SINEAX V 60s f direct currents, direct voltages, temperature senss, teletransmitters potentiometers 00 SINEAX V60s is a multifunctional transmitter f top-hat rail assembly with the following main characteristics:

More information

KINAX WT 707 Transmitter for angular position

KINAX WT 707 Transmitter for angular position Ruggedized version pplication The KINX WT 707 (Figs. 1 to 6) converts the angular position of a shaft into a load-independent direct current signal, proportional to the angular position. The unit is contact

More information

RISH Ducer E13 3 channel transducer for AC current and voltage

RISH Ducer E13 3 channel transducer for AC current and voltage RISH Ducer E13 3 channel transducer for C current and voltage The RISH Ducer E13 ( Fig. 1) converts 3 sine wave C current or C voltage into 3 output signals that can serve several receiving instruments

More information

Rudder or propeller angular position transmitter KINAX WT720

Rudder or propeller angular position transmitter KINAX WT720 Description The is a robust, absolute angular position transmitter, which is particularly suitable for use in marine applications such as the detection of rudder or propeller positions. In contrast to

More information

SINEAX VC 603, Programmable combined transmitter/alarm unit

SINEAX VC 603, Programmable combined transmitter/alarm unit for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The SINEAX VC 603 (Fig. 1) converts the input variable a DC current or voltage, or a signal

More information

EURAX UI 505, Combined Transducer for AC current and AC voltage

EURAX UI 505, Combined Transducer for AC current and AC voltage Plug-in module in Euro-format Application The transducers EURAX UI 505 (Fig. 1) are intended to simultaneous converts of up to 3 sinusoidal AC currents or voltages. Output signals available are load-independent

More information

Operating Instructions

Operating Instructions Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description

More information

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched

More information

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Vibration Transducer Supply Unit Series > For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic

More information

KINAX 3W2 Transmitter for angular position

KINAX 3W2 Transmitter for angular position KINX 3W2 For installation KINX 3W2 is a compact transmitter for angular position for installation in devices and apparatus. Due to its unique capacitive measuring principle, it acquires the angular position

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN Indicator and alarm signalling unit 10/30-2.10 EN Dimensions 36 mm x 144 mm Can either stand vertically or lie horizontally Comprehensively explosion-protected Robust moving-coil system Contactless alarm

More information

Isolators A3/1.

Isolators A3/1. > Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]

More information

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/ 3 Ex i Isolators Switching Repeater with Power Relay Intrinsically safe input [Ex ia] IIC Galvanic isolation between input, output and power supply Open-circuit / short-circuit monitoring and messaging

More information

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time

More information

for DC currents or voltages, temperature sensors, remote sensors or potentiometers Application Principle of operation (Fig. 3) Features / Benefits

for DC currents or voltages, temperature sensors, remote sensors or potentiometers Application Principle of operation (Fig. 3) Features / Benefits for s or voltages, temperature sensors, remote sensors or potentiometers pplication The universal transmitter RISH Ducer V 604 (Figures 1 and 2) convert the input variable a or voltage, or a signal from

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input

More information

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

Isolating Repeater Input Series 9163

Isolating Repeater Input Series 9163 > For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de

More information

Theta 20A / 20V. Technical Data Sheet. Special Features

Theta 20A / 20V. Technical Data Sheet. Special Features Technical Data Sheet Theta 20A / 20V Theta 20A / 20V is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal. Special Features Available in

More information

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New) XR1 Rotor Earth Fault Relay (May 2007) Manual XR1 (Revision New) Woodward Manual XR1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided

More information

RMA42. Technical Information

RMA42. Technical Information Technical Information RMA42 Process transmitter with control unit Digital process transmitter for mounting on a top-hat rail for monitoring and visualizing analog measured values Application Plant and

More information

Binary Output Series 9175

Binary Output Series 9175 Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use

More information

Contrans T TEU 471, TEU 471-Ex. Intelligent four-wire temperature transmitters EN

Contrans T TEU 471, TEU 471-Ex. Intelligent four-wire temperature transmitters EN Contrans T TEU 471, TEU 471-Ex Intelligent four-wire temperature transmitters Input/sensor connection: Resistance thermometers (2-, 3-, 4-wire circuit) Thermocouples (without, with internal/external reference

More information

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) Tranducers for alternating current/voltage n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) and input current range (for CIP-I) n Available in single or dual output type

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Binary Output without Power Supply Series 9176

Binary Output without Power Supply Series 9176 Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due

More information

Safety Instructions Nivotester FTC625, FTC325

Safety Instructions Nivotester FTC625, FTC325 XA01351F-A/00/EN/01.14 71273077 Products Solutions Services Safety Instructions FTC625, FTC325 [Ex ia Ga] IIC/IIB TÜV 13.0903 X Segurança TÜV INMETRO OCP 0004 Document: XA01351F-A Safety instructions for

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

MINI MCR-SL-UI-f(-SP)

MINI MCR-SL-UI-f(-SP) Configurable Analog Frequency Transducer INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The configurable analog frequency transducer MINI MCR-SL-UI-f(-SP) is used to convert analog standard

More information

ISOMETER IRDH575. Approvals

ISOMETER IRDH575. Approvals Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation

More information

SINEAX V604s Programmable multifunctional transmitter

SINEAX V604s Programmable multifunctional transmitter SINAX V60s for direct currents, direct voltages, temperature sensors, teletransmitters or potentiometers SINAX V60s is a multifunctional transmitter for tophat rail assembly with the following main characteristics:

More information

02/11/2015

02/11/2015 Emergency stop and safety guard monitoring 2 channels KNE3-YS Part number 85102436 "Emergency stop" & "Safety gates monitoring" functions Single and 2-channel operation Security with redundancy and feedback

More information

02/11/2015

02/11/2015 35 mm - 1 Relay 8A OUR3 Part number 88867103 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

Theta Hz. Technical Data Sheet. Special Features

Theta Hz. Technical Data Sheet. Special Features Technical Data Sheet Theta Hz Theta Hz the transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent

More information

PRetrans Table of contents

PRetrans Table of contents HART TRANSPARENT REPEATER PRetrans 5106 Table of contents Warnings 16 Safety instructions 17 EC Declaration of Conformity 19 How to demount SYSTEM 5000 20 Application 21 Technical characteristics 21 Mounting

More information

Technical Information RMA42

Technical Information RMA42 TI00150R/09/EN/05.16 71315973 Products Solutions Services Technical Information RMA42 Process transmitter with control unit Digital process transmitter for monitoring and visualizing analog measured values

More information

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex Data Sheet 10/-8.54 EN Level 0: Information FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Resistance thermometer (2,

More information

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting Electrical Temperature Measurement Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting WIKA Data Sheet TE 24.01 Applications T Machinery, plant construction T Process industry

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL acc. to IEC

More information

RISH Ducer E15 TRANSDUCER FOR AC CURRENT OR AC VOLTAGE WITH DIFFERENT CHARACTERISTICS

RISH Ducer E15 TRANSDUCER FOR AC CURRENT OR AC VOLTAGE WITH DIFFERENT CHARACTERISTICS RISH Ducer 5 TRNSDUCR FOR C CURRNT OR C VOLTG WITH DIFFRNT CHRCTRISTICS The RISH Ducer 5 transducer (Fig and ) is used where a sine-wave C current or voltage is to be converted into a DC signal proportional

More information

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays KSR-Level sensor KSR-Schwimmer-Magnetschalter 1001-5 KSR Contact Protection s 1 KSR Contact Protection Type KR230-Ex and KR24-Ex General Description The contact protection relays KR230-Ex and KR24-Ex transmit

More information

OPTITEMP TT 10 C/R Technical Datasheet

OPTITEMP TT 10 C/R Technical Datasheet OPTITEMP TT 10 C/R Technical Datasheet Analogue 2-wire temperature transmitter Temperature linear 4...20 ma output Rangeable with solder pads and potentiometers Easy wiring through large center hole The

More information

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting Data Sheet 10/86-2.36-EN All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting Compact robust power relay Type RH(M) 1003: 3 changeover contacts Type RH(M) 1004: 4

More information

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3. TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex Transmitter for temperature and direct current variables in four-wire circuit Transmitters TEU 315 and TEU 325 are designed for direct and alternating voltage measurement

More information

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications

More information

02/11/2015

02/11/2015 Emergency stop and safety guard monitoring 1 channel KNAC3-YS Part number 85103035 "Emergency stop" & "Gate monitoring" functions Single channel operation Security with redundancy and feedback circuit

More information

Rail mounted Temperature Transmitter TH102/TH102-Ex

Rail mounted Temperature Transmitter TH102/TH102-Ex Data Sheet 10/-8.54 EN Rail mounted Temperature Transmitter TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Input Resistance thermometer (2, 3, 4 wire circuit) Thermocouples

More information

05/09/2012

05/09/2012 17.5 mm EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer ON LED) Option

More information

Assembly. Front view. Power Rail

Assembly. Front view. Power Rail Thermometer Resistance Repeater Features Assembly 1-channel isolated barrier 24 V DC supply (Power Rail) RTD/resistance input Resistance output Accuracy 0.1 % Front view Removable terminals blue Function

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Universal Module HART for Zone 2 Series 9468/33 > 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on

More information

27/04/2015

27/04/2015 Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement

More information

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C) XR1 Rotor Earth Fault Relay Manual XR1 (Revision C) Woodward Manual XR1 (EN) Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by

More information

Temperature Transmitter itemp RTD DIN rail TMT 127

Temperature Transmitter itemp RTD DIN rail TMT 127 Technical Information TI 095R/09/en No. 51004790 Temperature Transmitter itemp RTD DIN rail TMT 127 Temperature Transmitter for Pt100 Resistance Thermometer Application Temperature transmitter with fixed

More information

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique Operator Manual Transmitters Series KAT-... Analog transmitters in 2-wire technique Important Safety Notes! In the case of non-observance of the installation and safety notes or improper use of the transmitter

More information

Technical Information Barrier RB223

Technical Information Barrier RB223 TI00132R/09/EN/13.14 71275790 Products Solutions Services Technical Information Barrier RB223 One or two-channel barrier Loop-powered barrier for the safe separation of 4 to 20 ma standard signal circuits

More information

Measuring current transformers of the W, W series

Measuring current transformers of the W, W series Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000

More information

08/07/2015

08/07/2015 17.5 mm - 1 Solid State Relay 0.7A MUS2 Part number 88827004 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external

More information

RISH Ducer V604 Programmable universal transmitter

RISH Ducer V604 Programmable universal transmitter RISH Ducer V64 Programmable universal transmitter Data Sheet Programmable Universal Transmitter RISH Ducer V64 RISH Ducer V64 Fig. Transmitter RISH Ducer V64 in housing S7 clipped on a p-hat rail Fig.

More information

LINAX 4000L Continuous-line recorder

LINAX 4000L Continuous-line recorder -48-852-0 4/2.99 1 to 4 line channels Format 144 mm x 144 mm, mounting depth 250 mm Combined recording table for roll chart (2 m) or fanfold chart (16 m) Measuring channels electrically isolated Rugged

More information

Type Nominal voltage (V) Code HSV V

Type Nominal voltage (V) Code HSV V Speed control Speed control relay - mm Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - -wire PNP or NPN, Namur, voltage 0-0V or volt-free contact type Works

More information

Phase control Single function phase control relay - 7.5 mm Control of -phase networks: phase sequence, total phase failure Multi-voltage from x 08 to x 480 V Controls its own supply voltage True RMS measurement

More information

Temperature transmitter itemp RTD DIN rail TMT 127

Temperature transmitter itemp RTD DIN rail TMT 127 Technical information TI 095R/24/ae Nr. 510 06165 Temperature transmitter itemp RTD DIN rail TMT 127 Pt100 transmitter for an economical, high accuracy temperature monitoring. Fixed range measurement,

More information

02/11/2015

02/11/2015 35 mm - 2 Relays 8A PL2R1 Part number 88867455 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+) Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature transmitter itemp PCP DIN rail TMT 121 Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

Single-Channel Safety Barriers Series 9001

Single-Channel Safety Barriers Series 9001 Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving

More information

MINI MCR-SL-UI-I-LP-NC

MINI MCR-SL-UI-I-LP-NC 2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.

More information

Temperature Measurement

Temperature Measurement Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal

More information

Remote Switching Unit nivotester FTL 320

Remote Switching Unit nivotester FTL 320 Technical Information TI 203F/24/ae Remote Switching Unit nivotester For connection to intrinsically safe Liquiphant level limit switches Applications Limit detection of fluids and bulk solids in tanks

More information