The Power in. Electrical Safety. Product presentation isohr685w-d/s-i-b. Updated: BENDER > isohr685 Mumtaz Farooqi
|
|
- Claud Patterson
- 6 years ago
- Views:
Transcription
1 The Power in Electrical Safety Product presentation isohr685w-d/s-i-b 1 Updated:
2 isohr685 content 1. IT systems and IMD 2. isohr Summary 2
3 IT system and Insulation Monitoring Device An IT (unearthed) system is used for high availability and safety systems e.g subsea umbilicals A first earth fault in IT system will not result in system shutdown, a 2 nd fault on different conductor will. An IMD continuously monitors the insulation resistance between the IT system and earth (PE) Optically signals a drop in insulation resistance below a minimum value Must comply with the requirements of the product standard for insulation monitoring devices IEC
4 Challenges in Umbilical Monitoring IMD, IR measurement range - typically 10/20MOhms Leakage capacitance Mixed networks AC+DC Measurement accuracy Compliance with standard IEC
5 isohr685 Insulation monitoring up to 1,000 VAC and 1,300 VDC (±15%) w/o AGH OVC III for <= 1,000 V OVC II for voltages > 1,000 V Measurement range 1 kω to 10 GΩ 2 different alarm values 1 kω to 3 GΩ Response time: dependent on profile Automatic adaption to capacitances up to 1,000 µf High resolution display for visualization of values and settings Measurement of U, f, C (U, f just for 690 VAC and 1,000 VDC) 5
6 Accuracy (U n = AC 690 V, f n = 50 Hz) Range < 10 MΩ 6
7 Accuracy (U n = AC 690 V, f n = 50 Hz) Range > 10 MΩ 7
8 isohr685 Wide range power supply AC/DC V (-20%...+15%) Free programmable digital inputs (3) and outputs (2) Free programmable analogue output (0 20mA, 4 20mA, 0-400µA, 0 10V, 2 10V) (10 kω 1 MΩ) Built-in webserver and data recording isodata Ambient temperature -40 C 55 C 8
9 isohr685 Monitoring Umbilicals up to 10 GΩ and to 150 µf: Insulation monitoring up to 1,500 VDC with OVC II Principle acc. to for AC, DC and AC/DC systems Monitoring of long parallel cables with new technology 9
10 Trending in high-ohmic area with integrated isograph 10
11 Monitoring long parallel cables simultaneously Coupling of both systems through capacitances IMDs are influencing themselves Solution: Synchronization of devices 11
12 Difference with and without synchronizing in 1 µf coupled system Synchronizing activated 12
13 Necessary connections and settings ISOsync has no limitations for the number of participants and works with synchronous time Time can be synchronized by the devices via BCOM OR Time can be synchronized by NTP Server (manual or DHCP) Switch NTP Server (optional) 13
14 Mastertitelformat bearbeiten Coupled systems with isohr685 Mastertextformat bearbeiten Zweite Ebene Dritte Ebene Vierte Ebene 2 devices can be controlled by a digital input. 1 potential free contact of the coupling contact is required. Just 690 VAC and 1,000 VDC Every isohr has an internal resistance of 50 MΩ approximate value
15 Mastertitelformat bearbeiten ISOnet with isohr685 via BCOM Mastertextformat bearbeiten Zweite Ebene Dritte Ebene Vierte Ebene 2 devices can control themselves if they are connected to each other via Ethernet. No Information of the coupling contact is required. Just 690 VAC and 1,000 VDC Every isohr has an internal resistance of 50 MΩ approximate value
16 Mastertitelformat bearbeiten ISOnet with isohr685 via BCOM Mastertextformat bearbeiten Zweite Ebene Dritte Ebene Vierte Ebene 2 up to 20 devices can control themselves via Ethernet. No information of the coupling switches necessary. They measure the systems one by one. Just 690 VAC and 1,000 VDC Every isohr has an internal resistance of 50 MΩ approximate value
17 As display and sensor variant available isohr685w-d-i-b Display Variant isohr685w-s-i-b + FP200W For new installations isohr685w-s-i-b + FP200W For retrofit installations IRDH375 For dimensions please refer to the documentation. 17
18 Summary isohr685 IT system used for high availability applications being tolerant to first earth fault IT system benefits and regulations require use of IMD isohr685 offers significant improvement on IR monitoring up to 10 GΩ Can be used in AC, DC and AC/DC systems Compliant to IEC (tripping also on symmetrical faults) Up to 1,000 VAC and 1,300 VDC Monitoring long parallel cables without cross influence ISOnet available for coupled systems Possibility for early insulation trending 18
19 Bender GmbH & Co. KG Londorfer Str Grünberg Pictures: Bender Archive, Subject to modification - Bender GmbH & Co. KG, Germany The presentation, its content, pictures and drawings are protected by copyright law. Duplication, translation, microfilming and transfer into any electronic systems, especially for commercial purposes is not allowed and subject to approval by the issuer. We do not assume any responsibility and liability for faulty or missing content. All data is based on manufacturers information. All logos and product descriptions are registered trademarks of the respective manufacturer. 19
Electrical Safety. Mastertitelformat bearbeiten. The Power in. Mastertextformat bearbeiten. Zweite Ebene. Dritte Ebene.
Mastertitelformat bearbeiten Mastertextformat bearbeiten Zweite Ebene The Power in Dritte Ebene Electrical Safety Vierte Ebene Phil Robinson Business Manager phil.robinson@bender-uk.com Mumtaz Farooqi
More informationISOMETER iso685- Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)
Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) iso685-x_d00022_08_d_xxen/04.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product
More informationISOMETER iso685- -B. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet
Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet iso685-x-b_d00177_04_d_xxen/04.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems
More informationISOMETER IRDH575. Approvals
Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation
More information2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 0640 807-0 Fax: 0640 807-259 IT system floor-standing distribution cabinet Series -IPS-F/EDS for supplying power to medical locations
More informationISOMETER iso685-d-p. Device features
ISOMETER iso6- -P Insulation monitoring device with integrated locating current injector for IT AC systems with galvanically connected rectifiers or converters and for IT DC systems iso6-x-p_d D_XXEN/.
More informationDipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-259 Insulation fault locator Insulation fault locator for DC IT systems with high system leakage capacitances
More informationAC/DC sensitive residual current monitoring module RCMB121-
AC/DC sensitive residual current monitoring module RCMB121- for safe charging of electrical vehicles according to IEC 62752 for IC-CPD and IEC 60364-7-722 for Wall Boxes Preliminary datasheet Vorläufiges
More informationISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances
ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances _D00108_00_D_XXEN/05.2015 ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances
More informationMeasuring current transformers of the W, W series
Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000
More informationPortable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an
EDS309 Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an equipment for insulation fault location EDS309x_D00012_02_D_XXEN/11.2018
More informationAC/DC sensitive residual current monitoring module RCMB121-
AC/DC sensitive residual current monitoring module RCMB121- for safe charging of electrical vehicles according to IEC 62752 for IC-CPD and IEC 60364-7-722 for Wall Boxes Vorläufiges Datenblatt RCMB121_D00267_01_D_XXEN/05.2018
More informationISOMETER IR Headline. Version V004. Vorläufiges Datenblatt
Headline ISOMETER IR155-4210 Sub-Headline Insulation monitoring device (IMD) for unearthed charging systems (IT systems), for e.g. electric vehicles Version V004 Vorläufiges Datenblatt TDB106035en / 06.2012
More informationRenewable energy Reliable and efficient use of the power of nature
Renewable energy Reliable and efficient use of the power of nature Solutions for electrical safety Electrical safety for efficient use of renewable energy Making efficient and reliable use of natural energy
More informationA-ISOMETER IR / IR
1 Headline A-ISOMETER IR155-4203 / IR155-4204 Sub-Headline Insulation monitoring device (IMD) for unearthed DC drive systems (IT systems) in electric vehicles Preliminary data sheet Vorläufiges Datenblatt
More informationMeasuring current transformers of the W AB(P) series
Measuring current transformers of the W AB(P) series W-AB(P)_D00074_02_D_XXEN/07.2017 Measuring current transformers of the W AB(P) series Product description Measuring current transformers of the W -AB
More informationThe Power in Electrical Safety
The Power in Electrical Safety Main Catalogue Edition BENDER Group Main Catalogue Edition Subject to change! Bender GmbH & Co. KG, Germany The catalogue and the articles and illustrations which it contains
More informationMeasuring current transformers of the W B series
Measuring current transformers of the W B series W-B_D00075_01_D_XXEN/09.2015 Measuring current transformers of the W B series Product description Measuring current transformers of the W B series are highly
More informationPortable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an
EDS309 Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an equipment for insulation fault location EDS309x_D00012_00_D_XXEN/05.2015
More informationTechnical data Insulation fault location system Device components
Technical data Insulation fault location system Device components Device type DS470-12 PRC470 Insulation coordination acc. to IC 60664-1: Rated insulation voltage AC 250 V AC 250 V AC 500 V Rated impulse
More informationPower Quality and Energy Measurement PEM533
Power Quality and Energy Measurement _D00013_02_D_XXEN/11.2014 Power Quality and Energy Measurement 0.5 S Product description The digital universal measuring device is suited for measuring and displaying
More informationProduct overview Insulation monitoring devices A-ISOMETER Insulation fault location systems EDS
1 Product overview Insulation monitoring devices A-ISOMETER Insulation fault location systems EDS 1 BENDER Group For a high level of operational and electrical system safety: Unearthed power supply systems
More informationPower Quality and Energy Measurement PEM575
Power Quality and Energy Measurement _D00016_03_D_XXEN/12.2015 Power Quality and Energy Measurement Product description The digital universal measuring device is suited for measuring and displaying electrical
More informationISOMETER Headline IR /IR
ISOMETER Headline IR155-323/IR155-324 Insulation Sub-Headline monitoring device (IMD) for unearthed DC drive systems (IT systems) in electric vehicles Version V4 Vorläufiges Datenblatt IR155-32xx-V4_D115_2_D_XXEN/9.216
More informationGround fault protection Photovoltaic systems
T M Ground fault protection Photovoltaic systems Brochure NAE1111045 / 07.2016 2 2016 NEC Energy Solutions, Inc. - Used with Permission ENHANCED SAFETY SOLUTIONS For solar arrays, from the leader in electrical
More informationXR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)
XR1 Rotor Earth Fault Relay (May 2007) Manual XR1 (Revision New) Woodward Manual XR1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided
More informationAC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300
Monitoring Technique VARIMETER IMD Insulation monitor RN 5897/300 0274214 Your Advantages For mobile generator sets according to DIN VDE 0100-551 Preventive fire and system protection Detection of symmetric
More informationPower Quality and Energy Measurement PEM735
Power Quality and Energy Measurement PEM75 PEM75_D00084_01_D_XXEN/01.2015 Power Quality and Energy Measurement PEM75 class A Product description The digital universal measuring device PEM75 is suited for
More informationisolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems
T M 1 isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE1012110 / 12.2011 isolr275 / AGH-LR Ground Fault Monitor
More informationPEM353. Universal measuring device
353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities
More informationQuanti GI GROUND BOND - INSULATION RESISTANCE. Reliable, Rugged, Fast, Accurate, Intrinsically Safe & Easily Programmable Measurements
Quanti GI GROUND BOND - INSULATION RESISTANCE Reliable, Rugged, Fast, Accurate, Intrinsically Safe & Easily Programmable Measurements GROUND BOND - G WHY? Ground bond test (also referred to as PE resistance
More informationXR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)
XR1 Rotor Earth Fault Relay Manual XR1 (Revision C) Woodward Manual XR1 (EN) Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by
More informationPower Quality and Energy Measurement PEM330/PEM333
Power Quality and Energy Measurement PEM330/PEM333 TDB310001en / 02.2013 Power Quality and Energy Measurement PEM330/PEM333 0.5S Product description The universal measuring device PEM330/333 is used to
More informationLED Driver Constant voltage
Driver LCU 35W 12/24V IP20 EXC EXCITE indoor IP20 series Product description LED Driver Universal input voltage range Constant output voltage Push terminals for simple wiring Nominal life-time up to 50,000
More informationCoupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC
Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation
More informationC B. Models. Models 2MOPP
AC/DC Medical Power Supplies High power density 3" x 5" open frame medical power supply 450 Watt with forced air cooling 320 Watt convection cooled without derating up to 50 C Medical certification to
More informationLED Driver Constant voltage
Driver LCU 100/96W 12/24V IP20 EXC EXCITE indoor IP20 series Product description LED Driver Universal input voltage range Constant output voltage Push terminals for simple wiring Nominal life-time up to
More informationLINETRAXX RCMB42. AC/DC sensitive residual current monitor for electric vehicle charging systems
IETRAXX RCMB42 AC/DC sensitive residual current monitor for electric vehicle charging systems RCMB42x_D00167_04_D_XXE/08.2018 IETRAXX RCMB42 AC/DC sensitive residual current monitor for electric vehicle
More informationLED Driver Constant voltage
Driver LCU 60W 12/24V IP20 EXC excite series Product description LED Driver Universal input voltage range Constant output voltage Push terminals for simple wiring Nominal life-time up to 50,000 h (at ta
More informationWhy the IT system is often the best choice for power supply systems of all types
Why the IT system is often the best choice for power supply systems of all types Let us start initially with a clear commitment: the IT system ("unearthed system") is a type of system infrequently used
More informationPower Quality and Energy Measurement PEM575
Power Quality and Energy Measurement _D00016_00_D_XXEN/06.2013 Power Quality and Energy Measurement Product description The digital universal measuring device is suited for measuring and displaying electrical
More informationOperating instructions Fail-safe delay timer AZS About this document. Content
8 Appendix 8.1 Wiring example...4 8.2 Integral System Diagnostics (ISD)....5 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101126753-
More informationTHE ELECTROM itig II MOTOR TESTER AND WINDING ANALYZER
THE ELECTROM itig II MOTOR TESTER AND WINDING ANALYZER AUTOMATED, SAFE, AND EASY TO USE TESTER. HIGH AND LOW VOLTAGE TESTS IN A LIGHTWEIGHT PACKAGE. The state of the art Electrom itig II provides a wide
More informationTECHNICAL DATA SHEET. Safety and function tester GLP1-g. Standard model GLP1-g ELECTRICAL SPECIFICATION
TECHNICAL DATA SHEET Safety and function tester GLP1-g Revision 2.7 / valid from July 2017 Standard model GLP1-g ELECTRICAL SPECIFICATION Supply voltage Mains frequency No load current consumption 110
More informationMeasuring current transformer for universal measuring devices
Measuring transformer for universal measuring devices Measuring--transformer-PQ_D0023_0_D_XXN/06.208 Measuring transformer for universal measuring devices Product description All measuring devices of the
More informationMETRATESTER 5+ Tester for DIN VDE /6.15
3-348-817-03 15/6.15 Applications Electrical safety testing of electrical equipment: per DIN VDE 0701-0702: 2008 by means of measurement of: Protective conductor resistance Insulation resistance Protective
More informationAC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/020
Monitoring Technique VARIMETER IMD Insulation monitor RN 5897/020 0277078 RN 5897/020 RP 5898 Product Description The insulation monitor RN 5897/020 of the VARIMETER IMD family provides best and up to
More informationDEIF A/S. Insulation monitor. Type SIM-Q
Insulation monitor 4921232C Monitoring of insulation resistance on ungrounded AC networks (IT network) Working voltage up to 69V AC, withstands up to V DC Measuring range 1...Mohm or 1...Mohm Alarm on
More informationQUINT-PS/ 3AC/24DC/10
Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 Description PHOENIX CONTACT - 09/2009 Features QUINT POWER power supply units Maximum system
More informationInsulating fault locator to locate insulation faults in ungrounded DC, AC and three-phase power supplies (IT systems)
EN Manual EDS44 /44 Insulating fault locator to locate insulation faults in ungrounded DC, AC and three-phase power supplies (IT systems) EDS44 _D M_XXEN/4. PLEASE READ THIS MANUAL AND ANY ACCOMPANYING
More informationLEAK CURRENT HiTESTER ST5540/ST Washington Street Melrose, MA Phone Toll Free
LEAK CURRENT HiTESTER ST5540/ST5541 Safety measuring instruments 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Leak Current Measurement
More information# Digital Multimeter
#61-797 Digital Multimeter - 1 - TABLE OF CONTENTS 1.Introduction Precautions and Safety Information Symbols Safety 2.Specifications General Specifications Electrical Specifications Required Equipment
More informationThe future of installation testing is here. The Fluke 1650 Series Multifunction Testers
The future of installation testing is here The Fluke 50 Series Multifunction Testers Fluke 50 Series Safer, easier installation testing. The 50 Series testers verify the safety of electrical installations
More informationGround Bond & Optional HV & HC Scanner. Ground Bond & Functional Run Test. Ground Bond, Functional Run Test & Line Leakage Test. Features and Benefits
Fully-Automated, Multi-Function Electrical Safety Compliance Analyzer Multi-function safety compliance analyzers with an enhanced graphic LCD provide complete test setup and results with an easy-to-use
More informationElectrical Test & Measurement Equipment
Appliance Tester MI 3309 Delta GT Earth Bond Test 200 ma Insulation resistance (250 VDC, 500 VDC) Insulation resistance of isolated accessible conductive parts Substitute leakage current (up to 19.99mA
More informationCoupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC
Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation
More informationQUINT-PS/ 3AC/24DC/40
Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum
More informationHV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point
2010 MAP Range HV / MV / LV electrical network quality analyzers Class A > Network quality Analyzers PRODUCT ADVANTAGES COMPLIANT with the EN 61000-4-30 standard, Class A DETECTION of the fault LOCATION
More informationInstallation/operation instructions. Insulation monitor type SIM-Q/SIM-Q LF D (UK) Measuring range 1...0Mohm or 10...
Installation/operation instructions Insulation monitor type SIM-Q/SIM-Q LF Monitoring of insulation resistance on an AC network Working voltage up to 690V AC, withstands up to 1000V DC Measuring range
More informationWelcome. Networking Event. 7 th September 2016
Welcome Networking Event 7 th September 2016 Subsea Industry Sectors Oil & Gas Defence Wave and Tidal Ocean Science Mining Offshore Wind Subsea UK Profile Founded in 2004; industry partnership with government
More informationQuanti Presentation. Finero 2010 For Finero s Distributors Internal Use Only.
Quanti Presentation Finero 2010 For Finero s Distributors Internal Use Only 1 QUANTI 1. WHO IS USING? 2. WHY TO TEST? 3. HOW THEY ARE USED? 4. STANDARDS AND DIRECTIVES 5. QUANTI TESTERS - FEATURES GENERAL
More informationIMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet
IMA 600 Watts Power Supply Series for medical and industrial applications Product datasheet 600 Watts Power Supply Series for medical and industrial applications Features Safety rated for Medical, Industrial
More informationInsulation Monitoring Relays CM range
Insulation Monitoring Relays CM range ABB s insulation monitoring relays CM range generator side converter line side converter DC 10... 24 kv, f = 50 Hz or 60 Hz line coupling transformer converter control
More informationPage 1 of 28. Ingo Röhr. Frank Hesmer
Page 1 of 28 TEST REPORT Engineering recommendation G83/1 Recommendation for the connection of small-scale embedded generators (up to 16 A per phase) in parallel with public low-voltage distribution networks.
More informationHI-Physix Laboratory, L-83, Sector-1, DSIDC Industrial Area, Bawana, Delhi. Discipline Electronics Testing Issue Date
Last Amended on - Page 1 of 14 I. AUDIO EQUIPMENT 1. Audio-Video and Similar Electronics Apparatus Safety Requirement Marking & Instructions Laser Radiation (Products Marked Class I only) Heating under
More informationLED Driver Constant voltage
Driver LCU 100/96W 12/24V IP20 EXC excite indoor IP20 series Product description LED Driver Universal input voltage range Constant output voltage Push terminals for simple wiring Nominal life-time up to
More informationZITARES CCD FX-20 25W SELV (isolated), adjustable functions and current, 1-channel, dimmable
Sample image ECG versions Model Order no. Output current 1) Output power CCD175-25FX-20/220-240/LI 10132980 100... 750 ma 2... 25 W 1) Adjustable by means of zitares360 software or resistor. Performance
More informationZITARES ICD SELV constant current control gear, 2-channel, dimm- and programmable
ECG versions Model Order no. Output currents 1) Output power ICD290-60LS-01/220-240/LI 10105905 2 x 250-900 ma 5-60 W ICD290-100LS-01/220-240/LI 10105906 2 x 250-900 ma 12.5-95 W 1) Adjustable for each
More information10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units
BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells
More informationLED Driver Linear / area fixed output
Driver LC 53W 5-35mA flexc lp ANCED series Product description Built-in constant current LED Driver New version DC operating with EL marking Adjustable output current between 5 and 35 ma Max. output power
More informationMultifunction AC/DC Voltage Tester
User Manual Multifunction AC/DC Voltage Tester Model 20250-59 THE STANDARD IN PRECISION MEASUREMENT 1065DGMAN_20250-59 DS multifunctional voltage tester.indd 1 8/8/2017 1:37:47 PM Introduction The Digi-Sense
More informationOrbital GFI Inverter Series
Orbital GFI Inverter Series Datasheet Key Features One, split or three phases and up to 25 kva Superior efficiency of 95% CAN Bus control and DAQ Power quality and EMC compliance in accordance with European
More informationKeep the power running safely at sea. Vigilohm Insulation Monitoring For reliable electrical network availability in Marine
Keep the power running safely at sea Vigilohm Insulation Monitoring For reliable electrical network availability in Marine 2 3 What is at stake on a ship? Ships are a very unique type of building. When
More informationINSULATION TESTER SERIES
INSULATION TESTER SERIES Field measuring instruments A Full Line-up of Insulation Testers to Suit Any Need From Basic Testing to High Performance Analysis 2 INSULATION TESTER SERIES Selection guide IR4056-20
More informationLINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems -A_D00001_01_D_XXE/09.2015 LIETRAXX -A etwork and system protection (S protection) for
More informationLED Driver Compact dimming
Driver LCAI 35W 3mA 900mA ECO C flat ECO series Product description Dimmable built-in LED Driver for LED Constant current LED Driver Output current adjustable between 3 900 ma Max. output power 35 W Nominal
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationIMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet
IMA 1000 Watts Power Supply Series for medical and industrial applications Product data sheet Features 1000 Watts Power Supply Series for medical and industrial applications Safety rated for Medical, Industrial
More informationsatech SynchroStar GPS 200 Series
satech SynchroStar GPS 200 Series KEY BENEFITS Designed with high quality oscillator OCXO the device is characterized by superior frequency stability and improved holdover performance that allows maintaining
More informationIndeks: WMXXCMM60 Advanced Industrial Multimeter
CMM-60 Indeks: WMXXCMM60 Advanced Industrial Multimeter Description The CMM-60 multimeter allows you to record data thanks to the Trend Capture function of the built-in memory as well as the possibility
More informationInsulation Guard IW 1000 Monitoring of ungrounded AC- and DC voltage systems up to 690V
Insulation Guard IW 0 Monitoring of ungrounded AC- and DC voltage systems up to 690V Features M Time optimized pulse measuring method M Safe monitoring at extreme conditions (frequency converter, phase
More informationPHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 350mA 550mA ECO lp ECO series
Product description Dimmable built-in LED Driver for LED Constant current LED Driver Output current adjustable between 350 550 ma Max. output power 20 W Nominal life-time up to 100,000 h 5-year guarantee
More informationEmergency lighting units EM powerled
CPS FX 80 W ED Driver for AC and DC power supplies Product description Fixed-output ED Driver for mains operation with integrated Simple CORRIDOR FUCTIO (CF) Emergency lighting function for use in central
More informationLED Driver Linear / area dimming. Udriver LCAI 20W 350mA 550mA ECO lp ECO series
Udriver LCAI 20W 350mA 550mA ECO lp ECO series Product description Dimmable built-in LED Driver for LED Constant current LED Driver Output current adjustable between 350 550 ma Max. output power 20 W Nominal
More informationPHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 150mA 400mA ECO lp ECO series
EL Product description Dimmable built-in LED Driver for LED Constant current LED Driver Output current adjustable between 150 400 ma Max. output power 20 W Nominal life-time up to 100,000 h 5-year guarantee
More informationDIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)
PERFORMANCES 12 ranges of AC current from 16 ma to 128 A peak AC permanent current up to 26 ARMS Nine ranges of DC permanent current from 16 ma to 12 A DC current ± 6mA or ± 10 ma stackable to AC current
More informationELECTRICAL TESTING AND SAFETY
ELECTRICAL TESTING AND SAFETY Electrical installation testing The risks linked to incorrect use of electricity may include: -life-threatening danger for people, -threat of damage to electrical installations
More informationInsulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC
Data sheet Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC The CM-IWN serves to monitor insulation resistance in accordance with
More informationEMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.
Electronic monitoring relay for voltage monitoring in three-phase networks INTERFACE Data sheet 102110_en_03 1 Description PHOENIX CONTACT - 09/2009 Features Increasingly higher demands are being placed
More informationProduct overview. ISOMETER Insulation monitoring devices ISOSCAN Insulation fault location systems EDS
Product overview ISOMETER Insulation monitoring devices ISOSCAN Insulation fault location systems EDS 2 Find out today what will not happen tomorrow Reporting critical operating states today, so that unwanted
More informationHO118 Binning Interface User Manual * * Version 02. User Manual. Test & Measurement
HO118 Binning Interface User Manual *5800490502* 5800490502 Test & Measurement User Manual Version 02 Important hints Important hints Warranty and Repair Security This instrument has been designed and
More informationEfficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.
Features Regulated Converter Universal Input VAC 3W PCB Mount Package
More informationDescription. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461
October 13, 2017 Annexe to: IECEx CML 15.0063X Issue 1 Applicant: Apparatus: Braun GmbH Isolating Amplifier D461 Description The Isolating Amplifier D461 is an intrinsic safety associated apparatus
More informationMIT480/2 Insulation testers
MIT480/2 Insulation testers MIT480/2 Insulation testers Insulation testing up to 500 V and 100 GΩ range in a hand held instrument 3 wire connection for A, B and E (Tip, Ring and Earth) connection (New)
More informationSWT 3000 Teleprotection technical data siemens.com
Power network telecommunication SWT 3000 Teleprotection technical data siemens.com Sustainable success for high-voltage power networks The SWT 3000 Teleprotection system has been the first choice for reliable
More informationTop-Innovator MotorAnalyzer 2. Multi-purpose testers for electric motors and windings. Made in Germany Expect more.
Top-Innovator 2014 MotorAnalyzer 2 Multi-purpose testers for electric motors and windings Made in Germany Expect more. EN Winding testers 1 The MotorAnalyzer 2 unbeatably versatile The all-purpose MotorAnalyzer
More informationIMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet
IMA 400 Watts Power Supply Series for medical and industrial applications Product data sheet 400 Watts Power Supply Series for medical and industrial applications Features Safety rated for Medical, Industrial
More informationInsulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC
Data sheet Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC The CM-IWN.x serves to monitor insulation resistance in accordance with IEC
More informationZITARES NCD FX-30 Non-SELV (isolated), constant current control gear, 1-channel, dimmable
ECG versions Model Order no. Output current 1) Output power NCD140-70FX-30/220-240/LI 10142659 100... 400 ma 10... 70 W NCD175-100FX-30/220-240/LI 10142661 350... 750 ma 35... 100 W 1) Adjustable by means
More informationQUINT-PS/ 1AC/24DC/20
Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data sheet 103129_en_04 1 Description PHOENIX CONTACT - 02/2010 Features QUINT POWER power supply units Maximum system
More information