DIN 48 SIZE DIGITAL TIMER. UL File No.: E C-UL File No.: E122222
|
|
- Georgina Hunter
- 5 years ago
- Views:
Transcription
1 DIN SIZE DIGIAL L4H/-L imers L4H imers Pin type 4..9 mm inch Screw terminal type RoHS Directive compatibility information UL File No.: E C-UL File No.: E Features. Bright and Easy-to-Read Display A brand new bright -color back light LCD display. he easy-to-read screen in any location makes checking and setting procedures a cinch.. Simple Operation Seesaw buttons make operating the unit even easier than before.. Short Body of only 4. mm.9 inch (screw terminal type) or. mm. inch (pin type) With a short body, it is easy to install in even narrow control panels. 4. Conforms to IP s Weather Resistant Standards he water-proof panel keeps out water and dirt for reliable operation even in poor environments.. Screw terminal (M.) and Pin ypes are Both Standard Options he two terminal types are standard options to support either front panel installation or embedded installation.. Changeable Panel Cover Also offers a black panel cover to meet your design considerations.. Compliant with UL, c-ul and CE. Product types ime range mode Output voltage Power down insurance erminal type Part number s (. s~) s (. s~) s (. s~) 9999 s ( s~) 99 min 9 s ( s~) min (. min~) 99 h 9 min ( min~) h (. h~) Power delay () Power delay () Signal delay Signal delay Pulse One-shot Pulse -delay Signal Flicker otalizing -delay ( modes) Relay ( c) ransistor ( a) * A rubber gasket (AC) and a mounting frame (A-DA4) are included. to 4 V AC 4 V AC to 4 V DC to 4 V AC 4 V AC to 4 V DC Available pins L4H-AC4V pins Screw terminal pins Screw terminal pins Screw terminal pins Screw terminal L4H-AC4V L4H-AC4VS pins L4H-AC4V pins Screw terminal L4H-AC4V L4H-AC4VS pins L4H-DC4V pins L4H-AC4V L4H-AC4V L4H-AC4VS pins L4H-AC4V pins Screw terminal L4H-DC4V L4H-DC4VS L4H-AC4V L4H-AC4VS pins L4H-DC4V L4H-DC4V L4H-DC4VS
2 L4H-L imers 4..9 mm inch UL File No.: E C-UL File No.: E Features. Economically priced in anticipation of market needs. Economically priced to provide excellent cost performance.. Display is a bright reflective-type LCD.. Inherits all of the characteristics of the L4H digital timer. Seesaw switches ensure easy operation. IP environmental protection. Shortened body (. mm. inch underhead). L4H/-L 4. Compliant with UL, c-ul and CE. Product types Product name ime range mode Output voltage Power down insurance erminal type Part number L4H-L digital timer Part names s (. s~) s (. s~) s (. s~) 9999 s ( s~) 99 min 9 s ( s~) min (. min~) 99 h 9 min ( min~) h (. h~) Power delay () Power delay () Signal delay Signal delay Pulse One-shot Pulse -delay Signal Flicker otalizing -delay ( modes) Relay ( c) ransistor ( a) to 4 V AC 4 V AC/DC to 4 V DC to 4 V AC 4 V AC/DC to 4 V DC Available pins L4HL-AC4V L4HL-AC4V L4HL-DC4V L4HL-AC4V L4HL-AC4V L4HL-DC4V ime delay indicator Controlled output indicator indicator indicator switch switch OP. RS L4H h m s (Countdown time display) Elapsed time display Set time display ime units display Up keys Down keys 4 (Same for screw terminal type and -pin type) DIP switches
3 L4H/-L Specifications Item Rating ime accuracy (max.) Contact Life Electrical Mechanical conditions Rated operating voltage ype Rated frequency Rated power consumption Rated control capacity ime range ime counting direction Operation mode // input input Input signal Indication Power failure memory method time fluctuation emperature error Voltage error Setting error Contact arrangement Contact resistance (Initial value) Contact material Mechanical (contact) Electrical (contact) Allowable operating voltage range Breakdown voltage (Initial value) Insulation resistance (Initial value) voltage reset time emperature rise Vibration resistance Shock resistance Connection Protective construction Functional Destructive Functional Destructive Ambient temperature Ambient humidity Air pressure Ripple rate Applicable standard Ralay output type AC type AC/DC type DC type to 4 V AC, 4 V AC, to 4 V DC 4 V AC/DC / Hz common Max. V A Max. W A, V AC (resistive load) s, s, s, 9999 s, 99 min 9 s, min, 99 h 9 min, h (selected by DIP switch) Addition ()/Subtraction () ( directions selectable by DIP switch) A (Power delay ), A (Power delay ), B (Signal delay), C (Signal delay), D (Pulse one-shot), E (Pulse delay), F (Signal Flicker), G (otalizing delay) (selectable by DIP switch) Min. input signal width: ms, ms ( directions by selected by DIP switch) (he -pin type does not have a stop input.) Min. input signal width: ms (he -pin type does not have a lock input.) Open collector input Input impedance: Max. kω; Residual voltage: Max. V Open impedance: kω or less, Max. energized voltage: 4V DC -segment LCD (L4H, L4H-L common), Elapsed value (backlight red LED), Setting value (backlight yellow LED) ± (. % + ms) in case of power on start ± (. % + ms) in case of input signal start imed-out Form C mω (at A V DC) Ag alloy/au flash Min. ope. (Except for switch operation parts) EEP-ROM (Min. overwriting) voltage: to % [ ] emperature: to + C +4 to + F Min. input signal width: ms. ope. (At rated control voltage) Min. ope. (At rated control voltage) to % of rated operating voltage, Vrms for min: Between live and dead metal parts (-pin), Vrms for min: Between input and output, Vrms for min: Between contacts Between live and dead metal parts Min. MΩ: Between input and output (At V DC) Between contacts Max.. s ransistor output type AC type AC/DC type to 4 V AC, 4 V AC, 4 V AC/DC / Hz common Max. V A ma, V DC DC type to 4 V DC Max. W imed-out Form A (Open collector), Vrms for min: Between live and dead metal parts (Pin type), Vrms for min: Between input and output Min. MΩ: Between live and dead metal parts Between input and output Max. C (under the flow of nominal operating current at nominal voltage) to Hz: cycle/min single amplitude of. mm.4 inch ( min on axes) to Hz: cycle/min single amplitude of. mm. inch ( h on axes) Min. 9 m. ft./s (4 times on axes) Min. 94 m 94. ft./s ( times on axes) C to C +4 F to + F Max. % RH (non-condensing) to, h Pa % or less % or less -pin/-pin/screw terminal IP (front panel with rubber gasket) Safety standard EN- Pollution Degree /Overvoltage Category II EMC (EMI)EN--4 Radiation interference electric field strength Noise terminal voltage (EMS)EN-- Static discharge immunity RF electromagnetic field immunity EF/B immunity Surge immunity Conductivity noise immunity Power frequency magnetic field immunity Voltage dip/instantaneous stop/voltage fluctuation immunity EN Group ClassA EN Group ClassA EN-4-4 kv contact kv air EN-4- V/m AM modulation ( MHz to GHz) V/m pulse modulation (9 MHz to 9 MHz) EN-4-4 kv (power line) kv (signal line) EN-4- kv (power line) EN-4- V/m AM modulation (. MHz to MHz) EN-4- A/m ( Hz) EN-4- ms, % (rated voltage) ms, % (rated voltage), ms, % (rated voltage), ms, 9% (rated voltage) (At V DC)
4 Dimensions L4H digital timer Screw terminal type (Flush mount) Pin type (Flush mount/surface mount) L4H/-L (units: mm inch) olerance: ±. ± OP. RS h m s L4H Dimensions for embedded installation (with adapter installed) Screw terminal type Pin type Rubber gasket AC (supplied) Panel Mounting frame for flush mount A-DA4 (supplied) Rubber gasket AC (supplied) Panel Mounting frame for flush mount A-DA4 (supplied) -pin type (p cap AD-RC sold separately) -pin type (p cap A-DP sold separately) OP. RS h m s OP. RS h m s.99.9 L4H L4H Dimensions for front panel installations DIN rail terminal block (-pin type A-DFK sold separately) (-pin type A-DFK sold separately) Device installation rail A-DLA (sold separately) 9. (9.). (.4) ( ) dimension is for -pin type. Installation panel cut-out dimensions he standard panel cut-out dimensions are shown below. Use the mounting frame (A-DA4) and rubber gasket (AC). min min For connected installations Note) : he installation panel thickness should be between and mm.9 and.9 inch. Note) : For connected installations, the waterproofing ability between the unit and installation panel is lost. A A = ( n.) +. erminal layouts and Wiring diagrams -pin type Relay output type ransistor output type 4 N.C. voltage + Screw terminal type Relay output type 9 N.C. N.O. N.O. 4 voltage + ransistor output type 9 -pin type Relay output type 4 9 voltage + N.C. N.O. ransistor output type 4 9 voltage + + voltage 4 + voltage 4 Note) For connecting the output leads of the transistor output type, refer to ) ransistor output on page.
5 L4H/-L Setting the operation mode, time range, and time Setting procedure ) Setting the operation mode and time range Set the operation mode and time range with the DIP switches on the side of the L4H timer. DIP switches *4 Item DIP switch Operation mode Refer to table Minimum input reset, start, and stop signal width ms ms ime delay direction Addition Subtraction ime range Refer to table * he -pin type does not have the stop input, so that the dip switch can be changed over between reset and start inputs. he signal range of the lock input is fixed (minimum ms). 4 DIP switches able : Setting the operation mode DIP switch No. Operation mode A: Power on delay A: Power on delay B: Signal on delay C: Signal off delay D: Pulse One shot E: Pulse On delay F: Signal Flicker G: otalizing On delay able : Setting the time range DIP switch No. ime range. s to s. s to s. s to s s to 9999 s min s to 99 min 9 s. min to min h min to 99 h 9 min. h to h (Same for screw terminal type) Notes: ) Set the DIP switches before installing the timer. ) When the DIP SW setting is changed, turn off the power once. ) he DIP switches are set as before shipping. Setting procedure ) Setting the time Set the set time with the keys ( and keys) on the front of the L4H timer. Front display section Q Elapsed time display W Set time display E ime delay indicator R Controlled output indicator indicator Y indicator U ime units display Changing the set time. It is possible to change the set time with the up and down keys even during time delay with the timer. However, be aware of the following points. ) If the set time is changed to less than the elapsed time with the time delay set to the addition direction, time delay will continue until the elapsed time reaches full scale, returns to zero, and then reaches the new set time. If the set time 4 OP. RS L4H h m s is changed to a time above the elapsed time, the time delay will continue until the elapsed time reaches the new set time. ) If the time delay is set to the subtraction direction, time delay will continue until regardless of the new set time.. If the set time is changed to, the unit will operate differently depending on the operation mode. ) If the operation mode is set to A (power on delay ) or A (power on Power failure memory he EEPROM is used for power failure memory. It has a life of Min. over-writings. he EEPROM is overwriting with the following timing. Output mode Overwrite timing Power delay () A When power is Addition G Change of preset value or start, reset input When power is after being Other modes When power is after changing preset value 9 I keys Changes the corresponding digit of the set time in the addition direction (upwards) O keys Changes the corresponding digit of the set time in the subtraction direction (downwards) P switch s the elapsed time and the output { switch s the operation of all keys on the unit delay ), the output will turn on when the power is turned on. However, the output will be off while reset is being input. ) In the other modes, the output turns on when the start is input. When the operation mode is C (signal off delay), D (Pulse one shot), or F (Signal flicker), only when the start input is on does the output turn on. Also, when the reset is being input, the output is off. * Be aware that the contents of EEPROM for all modes will be overwritten when power is turned during input to external lock terminals R to E and to. Such an action does not exist by doing lock operation from the front.
6 Operation mode Operation type Power on delay () A Explanation Set the operation mode section of the DIP switches (no. s,, and ) on the side of the timer as shown. Clears elapsed time value and starts time delay at power. After timer completion, stops at the display of the set value (addition), or stops at (subtraction). Ignores start input. s delay time operation at stop. Restarts delay time operation at stop. Power Output : Set time t, t, t, ta< ime chart t t t+t= L4H/-L Power on delay () A Set the operation mode section of the DIP switches (no. s,, and ) on the side of the timer as shown. Elapsed time value does not clear at power. (power outage countermeasure function) he output remains even after the power is cut and restarted. After timer completion, stops at the display of the set value (addition), or stops at (subtraction). Ignores start input. s delay time operation at stop. Restarts delay time operation at stop. Power Output t t t+t= Signal on delay B Set the operation mode section of the DIP switches (no. s,, and ) on the side of the timer as shown. Clears elapsed time value at power. ime delay starts at start and elapsed time value or output resets at start. Instantaneous time delay start at reset and power while start is. s delay time operation at stop. Restarts delay time operation at stop. In order to have the time delay start at power or reset at power, short out the start input beforehand. Power Output t t t+t= Signal off delay C Set the operation mode section of the DIP switches (no. s,, and ) on the side of the timer as shown. Clears elapsed time value at power. Output control at start and time delay start at start. Elapsed time value clears when start goes again during time delay. s delay time operation at stop. Restarts delay time operation at stop. Power Output >ta+tb >t ta tb t Notes: ) Each signal input (start, reset, stop, and lock) is applied by shorting their input terminal to the common terminal (terminal Q for the -pin type, terminal E for the -pin type, and terminal for the screw terminal type). ) he -pin type does not have a stop input or lock input.
7 L4H/-L : Set time t, t, t, ta< Operation type Explanation ime chart Pulse One-shot D Set the operation mode section of the DIP switches (no. s,, and ) on the side of the timer as shown. Clears elapsed time value at power. ime delay starts and output control at start. urns output control and clears elapsed time value at time-up. Ignores start input during time delay. s delay time operation at stop. Restarts delay time operation at stop. In order to have the time delay start at power or reset at power, short out the start input beforehand. Power Output >ta =t+t ta t t t Pulse On delay E Set the operation mode section of the DIP switches (no. s,, and ) on the side of the timer as shown. Clears elapsed time value at power. ime delay starts at start. Ignores start input during time delay. s delay time operation at stop. Restarts delay time operation at stop. In order to have the time delay start at power or reset at power, short out the start input beforehand. Power Output =t+t t t Signal Flicker F Set the operation mode section of the DIP switches (no. s,, and ) on the side of the timer as shown. Clears elapsed time value at power. ime delay starts at start. Ignores start input during time delay. Output control reverses, elapsed time value clears, and timer delay starts at timer completion. s delay time operation at stop. Restarts delay time operation at stop. In order to have the time delay start at power or reset at power, short out the start input beforehand. Power Output =t+t t t ta >ta =t+t t t otalizing On delay G Set the operation mode section of the DIP switches (no. s,, and ) on the side of the timer as shown. Elapsed time value does not clear at power. (power outage countermeasure function) he output remains even after the power is off and restarted. s delay time operation at stop. Restarts delay time operation at stop. Power Output =t+t+t >ta t t t ta Notes: ) Each signal input (start, reset, stop, and lock) is applied by shorting their input terminal to the common terminal (terminal Q for the -pin type, terminal E for the -pin type, and terminal for the screw terminal type). ) he -pin type does not have a stop input or lock input.
8 DIN SIZE DIGIAL L4H-W imers L4H-W 4..9 mm inch -pin type -pin type Screw terminal type RoHS Directive compatibility information UL File No.: E C-UL File No.: E Features. Wide time range he operation time range covers from. sec. to 9999 hours. he individual setting can be performed on each of and timers s 99min9s 99h9min 999.9s 999.9min 999.9h 9999s 9999h. Bright and Easy-to-Read Display A brand new bright -color back light LCD display. he easy-to-read screen in any location makes checking and setting procedures a cinch.. Simple Operation Seesaw buttons make operating the unit even easier than before. 4. Short Body of only 4. mm.9 inch (screw terminal type) or. mm. inch (pin type) With a short body, it is easy to install in even narrow control panels.. Conforms to IP s Weather Resistant Standards he water-proof panel keeps out water and dirt for reliable operation even in poor environments.. Screw terminal (M.) and Pin ypes are Both Standard Options he two terminal types are standard options to support either front panel installation or embedded installation.. Changeable Panel Cover Also offers a black panel cover to meet your design considerations.. Compliant with UL, c-ul and CE. 9. Low Price All this at an affordable price to provide you with unmatched cost performance. Product types ime range mode Output voltage Power down insurance erminal type Part number pins L4HW-AC4V to 4 V AC pins L4HW-AC4V Screw terminal L4HW-AC4VS pins L4HW-AC4V Relay ( c) 4 V AC pins L4HW-AC4V Screw terminal L4HW-AC4VS Pulse input: 99.99s pins L4HW-DC4V Delayed one shot 999.9s -start flicker to 4 V DC pins L4HW-DC4V 9999s -start flicker 99min9s Screw terminal L4HW-DC4VS Available 999.9min Integrating input: pins L4HW-AC4V 99h9min Delayed one shot 999.9h to 4 V AC pins L4HW-AC4V -start flicker 9999h -start flicker Screw terminal L4HW-AC4VS pins L4HW-AC4V ransistor ( a) 4 V AC pins L4HW-AC4V Screw terminal L4HW-AC4VS pins L4HW-DC4V to 4 V DC pins L4HW-DC4V Screw terminal L4HW-DC4VS * A rubber gasket (AC) and a mounting frame (A-DA4) are included.
9 L4H-W Part names / Operation display Display for change-over between / settings Controlled output indicator indicator switch Set/ switch OP. SE/ L4H-W h m s (Subtraction elapsed time display) Elapsed time display Set time display ime units display Up keys Down keys 4 DIP switches Fourth digit First digit (Same for -pin and screw terminal type) Specifications Item Rating ime accuracy (max.) Contact Life Electrical Mechanical conditions ype Rated operating voltage Rated frequency Rated power consumption Rated control capacity ime range ime counting direction Operation mode // input input Input signal Indication Power failure memory method time fluctuation emperature error Voltage error Setting error Contact arrangement Contact resistance (Initial value) Contact material Mechanical (contact) Electrical (contact) Allowable operating voltage range Breakdown voltage (Initial value) Insulation resistance (Initial value) voltage reset time emperature rise Vibration resistance Shock resistance Connection Protective construction Functional Destructive Functional Destructive Ambient temperature Ambient humidity Air pressure Ripple rate Ralay output type AC type to 4 V AC, 4 V AC / Hz common Max. V A A, V AC 99.99s, 999.9s, 9999s, 99min9s, 999.9min, 99h9min, 999.9h, 9999h (selected by DIP switch) Addition ()/Subtraction () ( directions selectable by DIP switch) Pulse input: Delayed one shot, -start flicker or -start flicker Integrating input: Delayed one shot, -start flicker or -start flicker Min. input signal width: ms, ms ( directions by selected by DIP switch) (he pin type does not have a stop input.) Min. input signal width: ms (he -pin type does not have a lock input.) Open collector input Input impedance: Max. kω; Residual voltage: Max. V Open impedance: kω or less, Max. energized voltage: 4 V DC -segment LCD, Elapsed value (backlight red LED), Setting value (backlight yellow LED) ± (.% + ms) in case of power on start ± (.% + ms) in case of input signal start imed-out Form C mω (at A V DC) Ag alloy/au flash DC type to 4 V DC Max. W Min. ope. (Except for switch operation parts) Min. ope. (At rated control voltage) EEP-ROM (Min. overwriting) to % of rated operating voltage, Vrms for min: Between live and dead metal parts (-pin type only), Vrms for min: Between input and output, Vrms for min: Between contacts Between live and dead metal parts Min. MΩ: Between input and output (At V DC) Between contacts Max.. s ransistor output type AC type DC type to 4V AC, 4V AC to 4 V DC / Hz common Max. V A Max. W ma, V DC voltage: % to % [ emperature: C to + C +4 F to + F Min. input signal width: ms ] imed-out Form A (Open collector) Min. ope. (At rated control voltage), Vrms for min: Between live and dead metal parts (Pin type only), Vrms for min: Between input and output Min. MΩ: Between live and dead metal parts Between input and output Max C (under the flow of nominal operating current at nominal voltage) to Hz: cycle/ min single amplitude of. mm.4 inch ( min on axes) to Hz: cycle/ min single amplitude of. mm. inch ( h on axes) Min. 9 m. ft./s (4 times on axes) Min. 94 m 94. ft./s ( times on axes) C to C +4 F to + F Max. % RH (non-condensing) to, h Pa % or less % or less -pin/-pin/screw terminal IP (front panel with rubber gasket) (At V DC)
10 Applicable standard Safety standard EN- Pollution Degree /Overvoltage Category II EMC Dimensions L4H-W digital timer (EMI)EN--4 Radiation interference electric field strength Noise terminal voltage (EMS)EN-- Static discharge immunity RF electromagnetic field immunity EF/B immunity Surge immunity Conductivity noise immunity Power frequency magnetic field immunity Voltage dip/instantaneous stop/voltage fluctuation immunity Screw terminal type (Flush mount) EN Group ClassA EN Group ClassA EN-4-4 kv contact kv air EN-4- V/m AM modulation ( MHz to GHz) V/m pulse modulation (9 MHz to 9 MHz) EN-4-4 kv (power line) kv (signal line) EN-4- kv (power line) EN-4- V/m AM modulation (. MHz to MHz) EN-4- A/m ( Hz) EN-4- ms, % (rated voltage) ms, % (rated voltage), ms, % (rated voltage), ms, 9% (rated voltage) Pin type (Flush mount/surface mount) L4H-W (units: mm inch) olerance: ±. ± OP. h m s SE/ L4H-W (Same for -pin type) Dimensions for flush mount (with adapter installed) Screw terminal type Pin type Rubber gasket AC (supplied) Panel Mounting frame for flush mount A-DA4 (supplied) Rubber gasket AC (supplied) Panel Mounting frame for flush mount A-DA4 (supplied) -pin type (p cap AD-RC sold separately) -pin type (p cap A-DP sold separately) OP. h m s OP. h m s.99.9 SE/ SE/ L4H-W L4H-W Dimensions for front panel installations 9. (9.). (.4) DIN rail terminal block (-pin type A-DFK sold separately) (-pin type A-DFK sold separately) Device installation rail A-DLA (sold separately) ( ) dimension is for -pin type. Installation panel cut-out dimensions he standard panel cut-out dimensions are shown below. Use the mounting frame (A-DA4) and rubber gasket (AC). min..min min..min. For connected installations When n timers are continuously installed, the dimension (A) is calculated according to the following formula (n: the number of the timers to be installed): A=( n.) +. A=( n.9) +.4 Note) : he installation panel thickness should be between and mm.9 and.9 inch. Note) : For connected installations, the waterproofing ability between the unit and installation panel is lost. A
11 L4H-W erminal layouts and Wiring diagrams -Pin type Relay output type ransistor output type -Pin type Relay output type ransistor output type N.C. 4 ( ) voltage (+) N.O. 4 ( ) voltage (+) 4 9 voltage + N.C. N.O. 4 9 voltage + Screw terminal type Relay output type ransistor output type 9 N.C. N.O Note) For connecting the output leads of the transistor output type, refer to ) ransistor output on page. + voltage + voltage
12 Setting the operation mode and time range Setting procedure ) Setting the time range (imer /imer ) Set the time range with the DIP switches on the side of the L4H-W timer. *4 Item ime range (imer ) DIP switch Refer to table Minimum input reset, start, and stop signal width ms ms ime delay direction Addition Subtraction ime range (imer ) Refer to table * he -pin type does not have the stop input, so that the dip switch can be changed over between reset and start inputs. he signal range of the lock input is fixed (minimum ms). 4 DIP switches Setting procedure ) Setting the operation mode Set the operation mode with the keys on the front of the L4H-W timer. Front display section Q Elapsed time display W Set time display E / operation indicator R / setting value selectable indicator Controlled output indicator Y indicator U ime units display (same for screw terminal type and -pin type.) 4 SE/ OP. L4H-W h Fourth digit m s First digit 9 able : Setting the time range (imer ) DIP switch No. ime range. s to s. s to s s to 9999 s min s to 99 min 9 s. min to min h min to 99 h 9 min. h to h h to 9999 h able : Setting the time range (imer ) DIP switch No. ime range. s to s. s to s s to 9999 s min s to 99 min 9 s. min to min h min to 99 h 9 min. h to h L4H-W h to 9999 h Notes: ) Set the DIP switches before installing the timer. ) When the DIP SW setting is changed, turn off the power once. ) he DIP switches are set as before shipping. I keys Changes the corresponding digit of the set time in the addition direction (upwards) O keys Changes the corresponding digit of the set time in the subtraction direction (downwards) P switch s the elapsed time and the output { SE/ switch Changes over the display between / settings, sets the operation mode, checks the operation mode and locks the operation of each key (such as up, down or reset key). ) Setting or changing the operation mode Ex: Setting operation mode display () When the or key at the first digit is pressed with the SE/ (PULSE-A example) switch pressed, the mode is changed over to the setting mode. () Now release the SE/ switch. () he operation mode in the setting mode is changed over sequentially in the left or right direction by pressing the or key at the first digit, respectively. Pulse input -start One operation Pulse input -start Repeating operation Pulse input -start Repeating operation Integrating input -start One operation Integrating input -start Repeating operation Integrating input -start Repeating operation (4) he operational mode displayed at present is set by pressing the switch, and the display returns to the normal condition. ) Setting (changing) the time () Pressing the SE/ key switches the set value display between and. Display the timer ( or ) which is to be set (or changed). () After displaying the timer ( or ) which is to be set, press the or key to change the time. Checking the operation mode When the or key at the second digit is pressed with the SE/ switch pressed, the operational mode can be checked. he display returns to the normal condition after indicating the operational mode for about two seconds. (While the display indicates the operational mode for about two seconds, the other indicators continue to operate normally.) Setting the lock When the or key at the fourth digit is pressed with the SE/ switch pressed, all keys on the unit are locked. he timer does not accept any of, and keys. o release the lock setting, press the or key at the fourth digit again with the set/lock switch pressed. * Operational mode, adding and subtracting and minimum input signal range cannot be set at and, respectively. Changing over the / setting display he / setting display is changed over by pressing the SE/ switch. (his operation gives no effect on the other operations. he set time and elapsed time (residual time) at are linked with those at.) Changing the set time ) It is possible to change the set time with the and keys even during time delay with the timer. However, be aware of the following points. () If the set time is changed to less than the elapsed time with the time delay set to the addition direction, time delay will continue until the elapsed time reaches full scale, returns to zero, and then reaches the new set time. If the set time is changed to a time above the elapsed time, the time delay will continue until the elapsed time reaches the new set time. () If the time delay is set to the subtraction direction, time delay will continue until regardless of the new set time. ) When the set times at and are set to, the output becomes only while the start input is carried out. However, while the reset input is carried out, the output becomes.
13 L4H-W OPERAI MODE PULSE : Pulse input INEGRAI : Integrating input PULSE A -start/ operation t <, t < INEGRAI A -start/ operation t <, t < Power ta+tb= tc+td= Power ta+tb= tc+td= te+tf= tg+th= A Delayed one shot Output ta tb tc td t t Output ta tb tc td te tf tg th t t Elapsed value cleared when power is turned on. ime limit start initiated when start input goes on; start input ignored if time limit interval is in progress. Elapsed value cleared when one operation has been completed. Elapsed value not cleared when power is turned on (power failure backup function). When power is turned back on, same status is maintained for output as that previous to power going off. Elapsed value cleared when one operation has been completed. PULSE B -start/repeating operation t <, t < INEGRAI B -start/repeating operation t <, t < Power ta+tb= tc+td= Power ta+tb= tc+td= te+tf= tg+th= B -start flicker Output ta tb tc td t t Output ta tb tc td te tf tg th t t Elapsed value cleared when power is turned on. ime limit start initiated when start input goes on; start input ignored if time limit interval is in progress. Elapsed value not cleared when power is turned on (power failure backup function). When power is turned back on, same status is maintained for output as that previous to power going off. PULSE C -start/repeating operation t <, t < INEGRAI C -start/repeating operation t <, t < Power ta+tb= tc+td= Power ta+tb= tc+td= te+tf= tg+th= C -start flicker Output ta tb tc td t t Output ta tb tc td te tf tg th t t Elapsed value cleared when power is turned on. ime limit start initiated when start input goes on; start input ignored if time limit interval is in progress. Elapsed value not cleared when power is turned on (power failure backup function). When power is turned back on, same status is maintained for output as that previous to power going off. Remarks and notes he pulse input mode starts the operation by starting the start input. When using the unit by starting it with the power on, shortcircuit the start terminal (-pin: Q to R, -pin: E to Y and screw terminal: to 9 ). he integrating input mode is operated by the integrated time of the start input. In other word, the timer operates only when the start input is performed. When the elapsed value is cleared by the reset input, the output is reset. When using the unit by starting it with the power on, shortcircuit the start terminal (-pin: Q to R, -pin: E to Y and screw terminal: to 9 ). Each signal input such as start, reset, stop and lock inputs is applied by short-circuiting its input terminal and common terminal (-pin type: terminal Q, -pin type: terminal E and screw terminal: terminal ) respectively. he -pin type does not have a stop input or lock input.
14 PRECAUIS IN USING HE L4H SERIES. erminal wiring ) When wiring the terminals, refer to the terminal layout and wiring diagrams and be sure to perform the wiring properly without errors. ) When using the instrument with an flush mounting, the screw-down terminal type is recommended. For the pin type, use either the rear terminal block (A4) or the P cap (AD-RC) for the -pin type, and the rear terminal block (A) or the P cap (A- DP) for the -pin type. Avoid soldering directly to the round pins on the unit. When using the instrument with a front panel installation, use the DIN rail terminal block (A-DFK) for the -pin type and the DIN rail terminal block (A- DFK) for the -pin type. ) After turning the unit off, make sure that any resulting induced voltage or residual voltage is not applied to power terminals W through U (-pin type) W through P (-pin type) or and (screw terminal type). (If the power wire is wired parallel to the high voltage wire or power wire, an induced voltage may be generated between the power terminals.) 4) Have the power voltage pass through a switch or relay so that it is applied at one time. If the power is applied gradually, the counting may malfunction regardless of the settings, the power reset may not function, or other such unpredictable occurrence may result.. Input connections he power circuit has no transformer (power and input terminals are not insulated). When an input signal is fed to two or more timers at once, do not arrange the power circuit in an independent way. If the timer is powered on and off independently as shown in Fig. A, the timer's internal circuitry may get damaged.be careful never to allow such circuitry. (Figs. A, B and C show the circuitry for the -pin type.) (Fig. A) Input contact point or transistor Input terminal Input terminal Power If independent power circuitry must be used, keep the input contacts or transistors separate from each other, as shown in Fig. B. (Fig. B) Input contact point or transistor Input contact point or transistor When power circuitry is not independent, one input signal can be fed to two or more counters at once, as shown in Fig. C. (Fig. C) Input contact point or transistor. Input and output ) Signal input type () Contact point input Use highly reliable metal plated contacts. Since the contact point s bounce time leads directly to error in the timer operations, use contacts with as short a bounce time as possible. Also, select a minimum input signal width of ms. -pin type input input Screw terminal type Input terminal Input terminal input input 4 -pin type 4 Input terminal Input terminal 9 Power Power () Non-contact point input Connect with an open collector. Use transistors whose characteristics satisfy the criteria given below. VCEO = V min. IC = ma min. ICBO = µa max. Also, use transistors with a residual voltage of less than V when the transistor is on. -pin type -pin type input to 4V DC Q input Screw terminal type Screw terminal type input input 4 -pin type 4 9 * he short-circuit impedance should be less than kω. [When the impedance is Ω, the current coming from the start input and stop input terminals is approximately ma, and from the reset input and lock input terminals is approximately. ma.] Also, the open-circuit impedance should be more than kω. * As shown in the diagram below, from a non-contact point circuit (proximity switches, photoelectric switches, etc.) with a power voltage of between and 4 V, the signal can be input without using an open collector transistor. In the case of the diagram below, when the non-contact point transistor Q switches from off to on (when the signal voltage goes from high to low), the signal is input. input 4 -pin type 4 9 (he above example is for reset input) ) he input mode and output mode change depending on the DIP switch settings. herefore, before making any connections, be sure to confirm the operation mode and operation conditions currently set. ) he L4H series use power without a transformer (power and input terminals are not insulated). In connecting various kinds of input signals, therefore, use a power transformer in which the primary side is separated from the ungrounded secondary side as shown in Fig. A, for the power for a sensor and other input devices so that short-circuiting can be prevented. 4
15 PRECAUIS IN USING HE L4H SERIES Once the wiring to be used is completely installed and prior to installing this timer, confirm that there is complete insulation between the wires connected to the power terminals ( each) and the wires connected to each input terminal. If the power and input lines are not insulated, a short-circuit may occur inside the timer and result in internal damage. In addition, when moving your equipment to a new installation location, confirm that there is no difference in environmental conditions as compared to the previous location. 4) he input signal is applied by the shorting of each input terminal with the common terminal (terminal Q for -pin types, terminal E for -pin types and terminal for screw terminal types). Never connect other terminals or voltages higher than 4V DC, because it may destroy the internal circuitry. ) ransistor output () Since the transistor output is insulated from the internal circuitry by a photocoupler, it can be used as an NPN output or PNP (equal value) output. (he above example is -pin type) As NPN output As PNP output (Fig. A) Good example AC power AC power Insulation transformer L4H timer { O I Load Load s power Load imer (Fig. B) Bad example AC power imer imer L4H timer { O I Load s power Note: With the -pin type, there is no diode between points I and O. (+) ( ) Insulation transformer (+) ( ) Single coil transformer (+) ( ) ( ) ( ) ( ) Input device (e.g., sensor) Input device (e.g., sensor) Input device (e.g., sensor) Alternative current flow () Use the diode connected to the output transistor s collector for absorbing the reverse voltage from induced loads. Diode rating: IF (forward current): A VR (reverse voltage): V L4H timer Load s power Inductive load ) When wiring, use shielded wires or metallic wire tubes, and keep the wire lengths as short as possible. ) For the load of the controlled output, make sure that it is lower than the rated control capacity. 4. Operation of L4H digital timer ) urning on and off the power while operating in A* (Power on delay ) or G (otalizing On delay) will result in a timer error to be generated due to the characteristics of the internal circuitry. herefore, use the start input or stop input. * Not related to the start input. ) When controlling the timer by turning on the power, use only A (Power on delay ) or A (Power on delay ). Use of other modes in this situation will result in timer errors. When using the other modes, control the timer with the start input or stop input.. Operation mode and time range setting he operation mode and time range can be set with the DIP switches on the side of the timer. Make the DIP switch settings before installing the timer on the panel. he operation mode of L4H-W series can be set with the keys and switches on the front of the timer.. Conditions of usage ) Avoid locations subject to flammable or corrosive gases, excessive dust, oil, vibrations, or excessive shocks. ) Since the cover of the timer is made of polycarbonate resin, avoid contact with or use in environments containing methyl alcohol, benzene, thinners, and other organic solvents; and ammonia, caustic sodas, and other alkaline substances. ) If power surges exceed the values given below, the internal circuits may become damaged. Be sure to use surge absorbing element to prevent this from happening. voltage Surge voltage (peak value) AC type,v DC type 4V AC type,v Surge wave form [± (. ) µs uni-polar full wave voltage] Surge voltage (%) 9. Peak ime (µs) 4) Regarding external noise, the values below are considered the noise-resistant voltages. If voltages rise above these values, malfunctions or damage to the internal circuitry may result, so take the necessary precautions. Noise voltage Noise wave form (noise simulator) Rise time: ns Pulse width: µs, ns Polarity: ± Cycle: cycles/second ) When connecting the operating power, make sure that no leakage current enters the timer. For example, when performing contact protection, if set up like that of fig. A, leaking current will pass through C and R, enter the unit, and cause incorrect operation. he fig. B shows the correct setup. power power Leakage current R (Fig. A) (Fig. B) C Power terminals AC type DC type 4V AC type R C Input terminals,v,v V
16 PRECAUIS IN USING HE L4H SERIES ) Long periods of continuous operation in the time-up completed condition (one month or more) will result in the weakening of the internal electrical components from the generated heat and, therefore, should be avoided. If you do plan to use the unit for such continuous operation, use in conjunction with a relay as shown in the circuit in the diagram below. R R Relay R imer R Receive output from contact at relay R. Acquisition of CE marking Please abide by the conditions below when using in applications that comply with EN-. ) Overvoltage category III, pollution level ) his timer employs a power without a transformer, so the power and input signal terminals are not insulated. () When a sensor is connected to the input circuit, install double insulation on the sensor side. () In the case of contact input, use dualinsulated relays, etc. ) he load connected to the output contact should have basic insulation. his timer is protected with basic insulation and can be double-insulated to meet EN/IEC requirements by using basic insulation on the load. 4) Please use a power that is protected by an overcurrent protection device which complies with the EN/IEC standard (example: V A fuse, etc.). ) You must use a terminal socket or socket for the installation. Do not touch the terminals or other parts of the timer when it is powered. When installing or un-installing, make sure that no voltage is being applied to any of the terminals. ) Do not use this timer as a safety circuit. For example when using a timer in a heater circuit, etc., provide a protection circuit on the machine side.. Self-diagnosis function If a malfunction occurs, one of the following displays will appear. Display Contents Malfunctioning CPU. Malfunctioning memory. See note. Note: Includes the possibility that the EEPROM s life has expired. Output condition Restoration procedure Preset values after restoration Enter reset input, key, or restart unit. he values at start-up before the CPU malfunction occurred. 49
17 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Panasonic: L4HW-DC4VS L4H-AC4V L4HW-AC4V L4H-DC4V L4H-DC4VS L4H-AC4VS L4HL-DC4V
DIN 48 SIZE DIGITAL TIMER. UL File No.: E C-UL File No.: E122222
DIN SIZE DIGITAL TIME 4..9 mm inch 8-pin type -pin type Screw type Product types UL File No.: E C-UL File No.: E Features Wide time range The operation time range covers from 0.0 sec. to 9999 hours. The
More informationELECTRONIC COUNTER (with pre-scaling function) UL File No.: E C-UL File No.: E122222
EECTRIC (with pre-scaling function) C-S Counters C-S -digit type -digit type pin type type U File No.: E C-U File No.: E Features. Bright and Easy-to-Read Display A brand new bright -color backlight CD
More informationDIN 48 SIZE LCD ELECTRONIC COUNTER. FEATURES 1. Two-stage presetting (upper and lower limits) SET2 SET1
C4-W DIN SIZE CD EECTRIC COUNTER C4-W U File No.: E CS File No.: R99.89 -pin type.89 64.5.59 mm inch type FETURES. Two-stage presetting (upper and lower limits) Count Output Output SET SET. Bright and
More informationCOMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291
COMP SIZE HIGH PRECISI IMERS VARIOUS OUPU & OPERAI MODE YPES SDX (one) SDX imers Features UL File No.: E22222 CSA File No.: LR3929 3 operation modes added for fuller lineup Now, operation modes include
More informationMULTI-RANGE ANALOG TIMER
MULI-RANGE ANALOG IMER PM4S imers PM4S RoHS Directive compatibility information http://www.nais-e.com/ Features 1. Economic pricing that promptly reflects market demands Remarkable economic pricing is
More informationDIN48 SIZE MULTI-RANGE ANALOG TIMER. Protective construction. Time range IP65 IP50 IP selectable ranges 1s to 500h IP50 IP65 IP50
12 Socket mount PRODUC YPE ype 62.5 2.461 Operation mode DIN SIZE MULI-RANGE ANALOG IMER mm inch Flush mount 8 operation modes Pulse -delay Pulse Flicker Pulse -flicker Differential /-delay (1) (2) Signal
More informationDIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS
DIN SIZE ANALOG MULI-ANGE CYCLIC WIN IMES UL File No.: E122222 CSA File No.: L39291 FEAUES A single twin timer unit that repeats (variable) ON/OFF. Multiple ranges with a.1 s to 5 h time specification
More informationTimers/Time Switches/Counters/Hour Meters
0 0 imers/ime Switches/Counters/Hour Meters MUI-RANGE ANAOG IMER PMS imers PMS Features. Economic pricing that promptly reflects market demands Remarkable economic pricing is implemented in pursuit of
More informationMulti Function Timer with Free power, Compact size W38 H42mm
Multi Function with Free power, ompact size W8 H4mm Features Wide power supply range : 100-40VA 50/0Hz, 4-40VD (universal), 4VA 50/0Hz / 4VD (universal), 1VD Various output operations( operation modes)
More informationModel Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models
Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model
More informationON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H
Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Solid-state Timer CSM DS_E_
More informationSolid-state Twin Timer
Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time
More informationModel Number Structure
Total Counter/Time Counter (DIN 72 x 36) CSM DS_E_4_1 DIN 72 x 36-mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 Large, easy-to-read displays:
More informationCount/Time Totalizers
/Time Totalizers Compact or Time Totalizers with Easy-to-Read and NEMA 4 Protection High-visibility, 8.5 mm negative transmissive LCD. NEMA 4 when used in conjunction with Y92S-32 rubber gasket supplied
More informationContents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers
Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2 for Low Voltage, and EMC Directives. Approved by UL and CSA. Lloyds/NK approvals.
More informationSolid-state Timer H3DS
Solid-state Timer H3DS DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to 230 VAC/VDC
More informationSolid-state Timer H3DE
Solid-state Timer H3DE DIN-rail Mounted, Standard 22.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/DC) reduces the number of timer models kept in stock. (except for H3DE-H) 12-VDC
More informationNo mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.
Series Digital LCD Timer DIN W48 H48mm Features Power supply : 4-4VAC 5/6Hz, 4-4VDC universal Easy to switch Up/Down mode programmable output modes and timing ranges () Selectable function by front digital
More informationSolid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A
Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2. Conforms to EMC standards (EN50081-2 and EN50082-2). Approved by UL and CSA. Lloyds/NK
More information02/11/2015
35 mm - 2 Relays 8A PL2R1 Part number 88867455 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external
More informationTimers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range
GT3A Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEDs UL,
More informationModel Number Structure
Total Counter/Time Counter (DIN 72 x 36) CSM DS_E_5_3 DIN 72 x 36-mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 Large, easy-to-read displays:
More informationLONG RANGE TRIGONOMETRIC AREA REFLECTIVE PHOTOELECTRIC SENSORS (AC OR DC POWER)
LG RANGE RIGOMERIC AREA REFLECIVE PHOOELECRIC SENSORS (AC OR DC POWER) MR3/MR3- Series FEAURES Long range sensors. he first long distance optical triangulation photoelectric sensors for 1 m ft. and 2 m
More informationOMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer
OMRON Analog Set Multifunction Timers Series To view data sheets, click on any link below: - Standard Timer -G - Star-Delta Timer -F - Twin Timer -H - Power OFF- Delay Timer Multifunction Timer Analog
More informationTimers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.
GT3A GT3A Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEDs
More informationCompact Relay Family with Forcibly Guided Contacts
Compact Relay Family with Forcibly Guided Contacts SF-Y RELAYS -pole ( Form A Form B, Form A Form B) -pole ( Form A Form B, 5 Form A Form B) RoHS compliant FEATURES. Forcibly guided contact structure Relay
More informationBulletin 700-HX Multifunction Digital Timing Relay
Bulletin 700-HX Multifunction Digital Timing Relay Model Operating Mode Timing Range Socket Type Contact Output No. of Pins Input Voltage Cat. No. Cat. No. 700 HX A mode: Signal ON-Delay 1 A-1 mode: Signal
More informationSelf-powered Counter
Self-powered Counter Subminiature Totalizing Counter Requires No External Power Supply DIN-sized 48 24 mm Wire-wrap terminal and screw terminal types available. AC/DC voltage, DC voltage, and No-voltage
More informationSolid-State Digital Counter H7AN
Solid-State Digital Counter Preset and Totalizing Counters with Up to 8-Digit LED Displays Draw-out construction allows setting, servicing without disconnecting wiring Choose from selectable UP/DOWN or
More information02/11/2015
35 mm - 1 Relay 8A OUR3 Part number 88867103 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external
More informationTechnical Information General Purpose Relays
Glossary CONTACTS Contact Form The contact mechanism of the Relay. Number of Contact Poles The number of contact circuits. Rated Load The rated load of the contact of the Relay, which determines the characteristic
More informationPART NUMBERING SYSTEM
Plug-In Timer 11 pins Multifunction or monofunction Compact body for space saving Wide time range (from 0.5 seconds to 10 days delay) Universal power supply (12-240 Vz) 1 or 2 relay outputs (SPDT / Changeover)
More information22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection
Relays 22 Technical Data...1 Specifications...2 Model Number Structure - Relays...3 Model Number Selection... 4-5 Electrical Characteristics...6 Accessories...7 Dimensions...8 Instructions...10 Safety
More informationPanel Mount PLC. NEW standard: Timer + Counter + Temperature Controller + PLC. The FP-e PLC comes in the following three types
Panel Mount PC NEW standard: Timer Counter Temperature Controller PC From the makers of the first SIM FP0 PC, Panasonic Electric Works is proud to introduce the industry's first panel mount PC, the FP-e.
More informationRelays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.
RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in
More informationTimers GE1A. GE1A Series ON Delay Timers Single Function
Key features: DPDT or SPDT + instantaneous SPDT 8-pin, octal base 8 time ranges Repeat error ±0.2% maximum Large, clear knob for easy setting Instant monitoring of operational status by LED indicators
More information11/03/2013
17.5 mm DIN rail mounting MUR1 Part number 88826105 TO BE SOON REPLACED BY THE NEW CHRONOS 2 RANGE (ref. 88827...) Relay or solid state output Multi-function or mono-function Multi-range Multi-voltage
More informationИ М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz
8 Pin Plug Type DIN W48 H48mm 8 Pin Plug Features Upgraded counting speed: 1cps / 3cps / kcps / 5kcps Selectable voltage input (PNP) method or no-voltage input () method Decimal point setting (fixed decimal
More information4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO
New Product News G9EJ--E Compact Capable of Switching 4 V A DC loads Actualize a high capacity interruption through the function of extinction of magnetic arc by adopting high-efficiency magnetic circuit.
More informationRT-3 UNIT RELAY 4-POINT TERMINAL
Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA Relay type, PhotoMOS Power (Voltage sensitive type)] RT-3 Unit relay -point Terminal [PA relay, PhotoMOS Power (Voltage sensitive
More informationTiming Mode Supply Voltage Trigger Options Reset Options Outputs Cat. No V AC Power On Power Off. Repeat Cycle OFF-Start
Bulletin -HR Plug-in iming Relays Product election/catalog Number Explanation Bulletin ON-Delay iming Relays ocket or Panel Mounted iming Range From. s h -pin base for socket cat. nos. -HN, -HN, -HN rigger:
More informationPalm-sized, 16-channel Relay Terminals
Palm-sized, -channel Relay Terminals RELAY TERMINAL FEATURES. Possible to select relay for use in the relay terminal in accordance with load. [Mountable relay: PA relay and Power PhotoMOS (voltage sensitive
More informationIDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)
IDEC RJ22 Series Slim Relays (Bifurcated Contacts) Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) High contact
More informationPhase-sequence Phase-loss Relay
Phase-sequence Phase-loss Relay K8AB-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Prevents reverse motor rotation due to incorrect wiring. Distinguishes between positive
More informationPARM-SIZED, 16-CHANNEL RELAY TERMINALS
Pressure connector connect type Wire-direct connect type PARM-SIZED, -CHANNEL RELAY TERMINALS FEATURES Compact, space-saving design: The Relay Terminal with I/O channels measures only (W) (D) (H) mm (W).
More informationMICRO LASER SENSORS. DISPLACEMENT LASER SENSOR The LM10 s cost-performance ratio far outstrips the competition.
MICRO SENSORS LM10 Series DISPLACEMENT SENSOR The LM10 s cost-performance ratio far outstrips the competition. Measurement Detection Shape recognition Position displacement measurement Thickness measurement
More informationPower supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits)
Controller CSM DS_E_3_1 Offers High-speed Input Response of 0.1 ms and Equipped with Built-in imer High-speed response of 0.1 ms. Ideal as a two-input Controller. Lineup includes the -BK with flip-flop
More informationModel Number Structure
Single-phase Voltage Relay CSM DS_E_3_1 Ideal for voltage monitoring for industrial facilities and equipment. Monitor for overvoltages or undervoltages. Manual resetting and automatically resetting supported
More informationULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage
TESTING ULTRA LOW PROFILE POLARIZED RELAY RELAYS 9...7 mm inch FEATURES Low profile mm.7 inch height High contact capacity: Surge withstand between contact and coil:, V (Telcordia) RoHS Directive compatibility
More informationDigital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE
Digital Panel Meter K3TE Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display with
More information02/11/2015
17.5 mm - 1 Relay 5A EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer
More informationRT-3 UNIT RELAY 4-POINT TERMINAL
Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA-N Relay type, PhotoMOS Power (Voltage sensitive type)] -point Terminal [PA-N relay, PhotoMOS Power (Voltage sensitive type)] Mountable
More informationSection. Timers. Selection Guide... G-2. Timing Diagrams Overview... G-4. W G RTE Series Analog Timers... G-8 Accessories... G-11 Dimensions...
Selection uide............. - iming Diagrams Overview....... - N! W RE Series Analog...... - NE ESI Accessories................. -11 D Dimensions.................. -1 A Series Analog.... -15 D Series Digital....
More informationMINIATURE RELAY FOR WIDER APPLICATIONS
TÜV Rheinland HJ MINIATURE RELAY FOR WIDER APPLICATIONS HJ RELAYS FEATURES contact arrangements Form C (for A 0 V AC), Form C (for 0 A 0 V AC)* Excellent contact reliability by Au plating Environmentally
More informationHIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES
HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE (60A type only) RELAYS A PC board type 80A Connector type 60A Screw terminal type A TM type 300A Connector type RoHS Directive compatibility
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
More informationA new approach to static electricity countermeasures
Advanced intelligent Sensors NEW ELECTROSTATIC SENSOR EF-SSERIES A new approach to static electricity countermeasures Measurement of surface potentials while a production line is running Phone: 8.894.42
More informationSolid-state Timer H3DE
Solid-state Timer H3DE CSM_H3DE_DS_E_3_2 DIN Track Mounted, Standard 22.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/DC) reduces the number of timer models kept in stock. (except
More information22/10/2012
22.5 mm DIN rail mounting TUR1 Part number 88865105 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator Option of connecting an external power supply
More informationCompliant with European standards 1a/1c 6A Slim power relays
PF (APF) VDE Compliant with European standards 1a/1c 6A Slim power relays PF RELAYS (APF) RoHS compliant FEATURES 1. High density mounting with mm.197 inch width Space saved with mm.197 inch slim type
More informationSUPER MINIATURE PC BOARD TYPE AUTOMOTIVE RELAY
SUPER MINIATURE PC BOARD TYPE AUTOMOTIVE RELAY CJ RELAYS (ACJ) RoHS compliant FEATURES Smallest in its class, it is extremely compact at approx. 2/3 the size of previous products. Compared to our previous
More informationCount - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2
Selection guide Count - counters Function Totalising counters Display type Mechanical LCD Font panel dimensions (h x w) in mm 0 x 0 x. 0 x 60 x Number of display digits 6 digits or 6 digits (depending
More information20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V
20 AMP POWER RELAY HG RELAYS a 3 1.4 5 RoHS Directive compatibility information http://www.nais-e.com/ a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A 250 V AC resistive and 1.5 kw 3 phase 220 V AC motor
More informationDIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure
New Product News Measuring & Monitoring Relays K8AK/K8DS Series DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays Compact 22.5 mm and 17.5 mm housings Resistant to high-frequency
More information05/09/2012
17.5 mm EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer ON LED) Option
More informationSelf-powered Tachometer
Self-powered Tachometer H7ER Revolutions displayed up to five digits. Dual revolution display accding to encoder resolution used; 1000 s 1 /1000 min 1 1000.0 s 1 /1000.0 min 1 Switchable dual revolution
More informationMasterINTERFACE 39 Series - Relay interface modules
Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic clip Dual screw head (blade+cross)
More information38 Series - Relay interface modules A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationTimers/Time Switches/Counters/Hour Meters
06 07 Timers/Time Switches/Counters/Hour Meters HOUR METER TH13 TH23 Hour Meters 52 2.047 52 2.047 54 2.126 TH23 series (with reset function) UL File No.: E42876 CSA File No.: LR39291 Features 1. High-performance
More informationTransistor drive 2c/4c 5A slim power relays
Transistor drive 2c/4c 5A slim power relays RELAYS 4 Flat type () 4 () 2 Flat type () 2 () FEATURES. Compact, slim design Use of high-performance flat electromagnetic design achieves 0.9 mm.429 inch profile,
More informationSlim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type
Slim type safety relays SF RELAYS Slim type RoHS compliant Protective construction: Flux-resistant type ORDERING INFORMATION S: Slim type Contact arrangement 2: 2 Form A 2 Form B 3: 3 Form A Form B 4:
More informationFor more information, please visit or call toll free at
GT3 GT3 Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEs UL,
More informationPART NUMBERING SYSTEM
Plug-In Timer pins Multifunction or monofunction Compact body for space saving Wide time range (from 0. seconds to 0 days delay) niversal power supply (-0 Vz) or relay outputs (SPDT / Changeover) Protective
More informationHigh switching capacity 1a/1c 30A power relays
Automation Controls Catalog High switching capacity 1a/1c 3A power relays JT-N RELAYS PCB type FEATURES High switching capacity: 3 A for 1 Form A 2 contact arrangements: 1 Form A or TMP types available
More informationFlat Proximity Switch
Type TL-PP702 Flat Proximity Switch Features Two-wire DC proximity switch with built-in connector. 4 mm in thickness. Prevention of connector disconnection and improvement of insertion easiness achieved
More informationSwitching & Controls Timers
Switching & Controls imers Selection Guide...792 RE Series Analog imers... 798 Accessories...803 Dimensions...804 G3A Series Analog imers... 805 G3D Digital imers...813 G3F Series rue OFF Delay imers 826...
More informationSolid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval
Solid-State Timer Analog Set Multifunction Timers in Slim Design for Track Mounting All settings are made though front panel Six operating modes in a single timer provides flexibility for many applications
More informationRE17LLBM asymmetrical flashing relay s V AC - solid state output
Characteristics asymmetrical flashing relay - 0.1..1 s - 24..240 V AC - solid state output Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 75.00 USD Main Range
More informationG70R-SOC08 CSM_G70R-SOC08_DS_E_2_1
Relay Terminal CSM DS_E 1 Space-saving and Labor-saving 8-point Output Block Relay terminal is just 136 80 55 mm (W H D, when mounted upright). Independent contacts and short bar allow easy common connections.
More informationEmitting and receiving element pitch: 10 mm in
Small / Slim Object Detection Area Sensor Cross-beam scanning system to detect slim objects Letter or visiting card detectable! Slim objects can be detected by using the cross-beam scanning system. Emitting
More informationTYPICAL COUNTER APPLICATIONS
TYPIAL OUNTE APPLIATIONS The highly accurate, reliable counters can be controlled from the front panel and are suitable for a wide range of applications. TYPIAL OUNTE APPLIATIONS DOWN and HOLD-A modes
More informationMK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure
General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E 1 New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator
More informationRE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC
Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Product availability : Stock - Normally stocked in distribution facility Price* : 75.00 USD Main Range of product Product
More informationCOMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS
COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS HK RELAYS (AHK) RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Compact and high-capacity Form C: A, Form C: high capacity
More informationLOW-PROFILE SURFACE-MOUNT RELAY
TESTING LOW-PROFILE SURFACE-MOUNT RELAY TQ SMD RELAYS.6. RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Low-profile: 6 mm.36 inch (Tape height: max. 6. mm.6 inch) Tape and reel
More informationRE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal
More information1a 8A, 1a1b/2a 5A small polarized power relays
Automation Controls Catalog a A, ab/a A small polarized power DSP RELAYS RoHS compliant Protective construction: Sealed type FEATURES. Compact with high contact rating Even with small mm. inch (H) mm.
More information08/07/2015
17.5 mm - 1 Relay 8A MUR1 Part number 88827105 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external load connection
More information38 Series - Relay interface modules A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationPD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description
Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer
More information02/11/2015
DIN Rail Mount 17.5 mm MXR1 Part number 88826185 Just one digit differentiates the new range part number from the old range's Previous part number : 88 826 XXX / new part number : 88 827 XXX Part numbers
More informationProximity Sensor Terminology
The following descriptions refer to the European standard EN 60947-5-2. of 2007. The specifications given here are intended to be minimum performance values described by the standard. Alignment must not
More informationC2UW. Wireless Hand Switches. Model. System Configuration. Push Button Switch. Model Number Structure
Push Button Switch Wireless Hand Switches Operability that s highly flexible and has a high degree of freedom has been realized. There is no need to worry about staining, disconnection, and entangling
More informationRE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O
Product data sheet Characteristics RE22R2MMU Multifunction Timer Relay - 24VDC/24..240 V AC - 2 C/O Main Range of product Product or component type Discrete output type Device short name Nominal output
More information08/07/2015
17.5 mm - 1 Solid State Relay 0.7A MUS2 Part number 88827004 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external
More informationRE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC
Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay
More informationRE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC
Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay
More informationAQ-R SOLID STATE RELAY FEATURES
(A 5A A type) SOLID STATE RELAY FEATURES. Two types of terminal shape: Plug-in terminal and Screw terminal ( A A is screw terminal types only). Flat type of SSR possible by aluminium printed circuit board.
More informationMINIATURE SIGNAL RELAYS
Information MINIATURE SIGNAL RELAYS UA SERIES (DIP Type) UB SERIES (SMD Type) TECHNICAL DATA EM Devices Corporation 17 EMDST5VOL1E17H The information in this document is based on documents issued in March,
More informationHIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE
HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE RELAYS (60A type only) 0A PC board type 0A TM type 60A Screw terminal type 80A Connector type 300A Connector type FEATURES. High-, high-current
More information