ELECTRONIC COUNTER (with pre-scaling function) UL File No.: E C-UL File No.: E122222
|
|
- Kathlyn Malone
- 5 years ago
- Views:
Transcription
1 EECTRIC (with pre-scaling function) C-S Counters C-S -digit type -digit type pin type type U File No.: E C-U File No.: E Features. Bright and Easy-to-Read Display A brand new bright -color backlight CD display. The easy-to-read screen in any location makes checking and setting procedures a cinch.. Easy to use, simple operation, simple settings Operation modes (input/output modes) can be set easily, using DIP switches on the side panel. Values can be set easily, using key switches on the front panel.. Pre-scaling function provided A pre-scaling function enables conversion of lengths and volumes to any desired values, and displays the results.. Built-in power supply for highcapacitance sensor An internal power supply drives a VDC, ma high-capacitance sensor. (AC power supply types only) Photoelectric switches, proximity switches and encoders can be directly connected.. Dual-path AC sensor can be connected.. Basic insulation between the power supply and the input terminal (only for the sensor type model with power supply) There is no need for caution when connecting between terminals.. Conforms to IP s Weather Resistant Standards The water-proof panel keeps out water and dirt for reliable operation even in poor environments.. -digit or -digit display Two sizes of displays are offered for you to choose the one that suits your needs.. and Pin Type are Both Standard Options The two s are standard options to support either front panel installation or embedded installation.. Compliant with U, c-u and CE.. ow Price All this at an affordable price to provide you with unmatched cost performance. Product types Digit Count speed Operation mode Output Operation Power for sensor Terminal Part No. z/ Kz switchable Maintain output/hold count Maintain output/over count I Maintain output/over count II One shot/over count One shot/recount I One shot/recount II One shot/hold count ( modes) Relay Transistor Relay Transistor to V AC to V DC / V AC to V DC / V AC to V AC to V DC / V AC to V DC / V AC Notes). Rubber packing (ATC) and an mounting frame (AT-DA) are included.. to VAC Tr outputs (-pin terminal, screw-tightening terminal) types are also supported. V DC ma None None V DC ma None None pins pins pins pins pins pins C-PS-R-AC C-PS-R-ACS C-S-R-V C-S-R-VS C-S-T-V C-S-T-VS C-PS-R-AC C-PS-R-ACS C-S-R-V C-S-R-VS C-S-T-V C-S-T-VS Phone:.. - Fax:.. - Web: info@clrwtr.com
2 C-S Part names -digit display type DIP switches Controlled output indicator indicator OCK Counter display Set value display ock indicator switch Set/lock switch SET/OCK C Up keys Down keys (Same for screw ) -digit display type DIP switches Controlled output indicator indicator OCK Counter display Set value display ock indicator switch SET/OCK Up keys Set/lock switch C (Same for screw ) Specifications Rating Contact ife Electrical Mechanical conditions Item Rated operating Rated frequency Rated power consumption Rated control capacity Input mode Max. counting speed Counting input (input, input ) input ock input Input signal Output mode One shot output time Indication Digit Decimal point Pre-scaling Memory Power for senser Contact arrangement Initial contact resistance Contact material Mechanical (contact) Electrical (contact) range Initial withstand Initial insulation resistance (At V DC) Temperature rise Vibration resistance Shock resistance Connection Protective construction Functional Destructive Functional Destructive Ambient temperature Ambient humidity Air pressure AC type to V Ralay output type DC/AC type to V DC/ V AC / z common Max. V A Max. W A V AC (resistive load) ma, V DC Addition ()/Subtraction ()/Direction (DIR)/Individuality (IND)/Phase (PASE) modes selectable by DIP switches z, kz (selectable by DIP switches). ms at z/. ms at kz time: time = : Min. input signal width: ms, ms (selected by DIP switches) Min. input signal width: ms Contact, Open collector input/dc two-wire system sensor Input impedance: kω or less, Input residual : V or less, Open impedance: kω or less, Max. energized : V DC OD-A, OD-B, OD-C, SOT-A, SOT-B, SOT-C, SOT-D, modes selectable by DIP switches s,.s,.s,.s,.,.s -segment CD, Counter value (backlight red ED), Setting value (backlight yellow ED) -digit display type to ( to for setting) -digit display type to ( to for setting) Can be set to three digits. to. (-digit type),. to. (-digit type) EEP-ROM (Overwriting times: ope. or more) V DC (±%) ma Max. Form C mω (at A V DC) Ag alloy/au flush ope. (Except for switch operation parts) ope. (At rated control ) to V AC. to. V DC,. to. V AC Between live and dead metal parts:, Vrms for min (pin type) Between input and output:, Vrms for min Between live and dead metal parts: Min. MΩ (pin type) Between input and output: Min. MΩ Max. C (under the flow of nominal operating current at nominal ) to z ( cycle/min), single amplitude:. mm ( min on axes) to z ( cycle/min), single amplitude:. mm ( h on axes) Min. m/s ( times on axes) Min. m/s ( times on axes) C to C F to F Max. % R (non-condensing) to, h Pa -pin/screw terminal IP (front panel with a rubber gasket) Transistor output type DC/AC type to V DC/ V AC Form A (Open collector) ope. (At rated control ) Phone:.. - Fax:.. - Web: info@clrwtr.com
3 Applicable standard C-S Safety standard EN- Pollution Degree /Over Category II EMC Dimensions (EMI)EN-- Radiation interference electric field strength Noise terminal (EMS)EN-- Static discharge immunity RF electromagnetic field immunity EFT/B immunity Surge immunity Conductivity noise immunity Power frequency magnetic field immunity Voltage dip/instantaneous stop/voltage fluctuation immunity EN Group ClassA EN Group ClassA EN-- kv contact kv air EN-- V/m AM modulation ( Mz to Gz) V/m pulse modulation ( Mz to Mz) EN-- kv (power supply line) kv (signal line) EN-- kv (power line) EN-- V/m AM modulation (. Mz to Mz) EN-- A/m ( z) EN-- ms, % (rated ) ms, % (rated ), ms, % (rated ), ms, % (rated ) mm inch General tolerance: ±. ±. ( (... Pin type (Flush mount/surface mount) type: M. (Flush mount).... ( (. s ((.) ((.) ((.) ((.) SET/OCK C.. (* -digit display type has the same dimensions.) *.*.*.*.*.* * With power supply for sensor * With power supply for sensor Dimensions for flush mounting (with adapter installed) type Rubber gasket ATC (supplied) Panel Mounting frame for flush mount AT-DA (supplied) Pin type Rubber gasket ATC (supplied) Panel Mounting frame for flush mount AT-DA (supplied) pin type pins cap: ATA (sold separately). OCK.. (. (.. OCK.. SET/OCK SET/OCK C C * With power supply for sensor * With power supply for sensor Dimensions for front panel installations DIN rail terminal block -pin type: AT-DFK (sold separately) Installation panel cut-out dimensions The standard panel cut-out dimensions are shown below. Use the mounting frame (AT-DA) and rubber gasket (ATC). Min For connected installations Device installation rail ATA (sold separately). (.). (.) * With power supply for sensor Min When n units are attached in a continuous series, the dimension of (A) is: A = ( n.). A Note : The installation panel thickness should be between and mm. and. inch. Note : For connected installations, the waterproofing ability between the unit and installation panel is lost. Phone:.. - Fax:.. - Web: info@clrwtr.com
4 C-S Terminal layouts and Wiring diagrams Pin type * With power supply for sensor Relay output type Transistor output type Relay output type Transistor output type Input NC Input Input NC Input Input NO Input Input NO Input ock ock ock ock V DC V ma Max. type * With power supply for sensor Relay output type Transistor output type Relay output type Transistor output type Input Input ock NC NO Input Input ock V DC V ma Max. Input Input Input Input ock NO ock NC V DC V ma Max. V DC V ma Max. Note) For connecting the output leads of the transistor output type, refer to ) Transistor output on page. Phone:.. - Fax:.. - Web: info@clrwtr.com
5 Setting the operation mode and counter Setting procedure ) Setting the operation mode (input mode and output mode) Set the input and output modes with the DIP switches on the side of the counter. DIP switches Item DIP switch Output mode Refer to table Minimum reset input signal width ms ms Maximum counter setting z kz Input mode Refer to table Table : Setting the output mode DIP switch No. Output mode SOT-A SOT-B SOT-C SOT-D OD-A OD-B OD-C (See note ) C-S DIP switches (See note ) (Same for -digit, screw-down ) Table : Setting the input mode DIP switch No. Input mode Addition input Subtraction input Directive input Independent input Phase input (See note ) (See note ) (See note ) Notes:) The counter and set value displays will display DIP Err. Notes:) Set the DIP switches before installing the counter on the panel. Notes:) When the DIP SW setting is changed, turn off the power once. Notes:) The DIP switches are set as before shipping. Setting procedure ) Setting the set value Set the set value with the and keys on the front of the counter. Front display section -digit display type Q Counter display W Set value display E Controlled output indicator R indicator T ock indicator Y keys Changes the corresponding digit of the set value in the addition direction (upwards) OCK SET/OCK C U keys Changes the corresponding digit of the set value in the subtraction direction (downwards) I switch s the counting value and the output O SET/OCK switch This is used to handle pre-scaling values, one-shot times, decimal point position settings, and key lock operations (to disable Up key, Down key, and key operations). -digit display type Q Counter display W Set value display E Controlled output indicator R indicator T ock indicator OCK SET/OCK C Y keys Changes the corresponding digit of the set value in the addition direction (upwards) U switch s the counting value and the output I SET/OCK switch This is used to handle pre-scaling values, one-shot times, decimal point position settings, and key lock operations (to disable Up key, Down key, and key operations). Setting procedure ) Setting the input mode The input mode is set using the key switch in the [Display] section on the front of the counter. Decimal point position setting mode Q olding down the [SET/OCK] key, press the key for the second digit to access the decimal point position setting mode. Example) -digit type Decimal point position setting mode display (Example shows default value displayed) W When the setting mode has been accessed, release the [SET/OCK] key. Phone:.. - Fax:.. - Web: info@clrwtr.com
6 C-S E The decimal point is set using the [] and [] keys to specify the nd, rd, and th digits (this applies only to -digit models).(the st digit is set using the [] key or [] key in settings where there is no decimal point (this applies only to -digit models).) Example) -digit type Example shows nd digit displayed using [] key R Press the [] key to set the displayed decimal point position and return to normal operation. Setting the pre-scaling value Q olding down the [SET/OCK] key, press the key for the first digit to access the pre-scaling value setting mode. Example) -digit type Example) -digit type Pre-scaling value setting mode displayed (Example shows default values displayed) W When the setting mode has been accessed, release the [SET/OCK] key. E Use the [] or [] key to set the pre-scaling value (this applies only to -digit models). Select either:. to. (-digit) or. to. (-digit) R Press the [] key to set the displayed pre-scaling value and return to normal operation. Setting the one-shot output time Q olding down the [SET/OCK] key, press the key for the third digit to access the one-shot output time setting mode. Example) -digit type One-shot output time setting mode displayed (Example shows default value displayed) W When the setting mode has been accessed, release the [SET/OCK] key. E Each time the st-digit [] key is pressed, the one-shot output time changes in the following sequence, moving to the right: s. s. s. s. s. s (With a -digit type, the [] key can also be used to move to the left.) R Press the [] key to set the displayed one-shot output time and return to normal operation. Changing the set value. It is possible to change the set value with the up and down keys (- digit type only) even during counting. owever, be aware of the following points. ) If the set value is changed to less than the count value with counting set to the addition direction, counting will continue until it reaches full scale ( with the -digit type and with the -digit type), returns to zero, and then reaches the new set value. If the set value is changed to a value above the count value, counting will continue until the count value reaches the new set value. ) Suppose that thew counter is preset to count down. Whether a preset countdown value is smaller or larger than the count value, the counter counts down to (zero).. If the set value is changed to, the unit will not complete count-up. It starts counting up when the counting value comes to (zero) again. ) Up-count (addition) input When counting is set to the addition direction, counting will continue until full scale is reached ( with the -digit type and with the -digit type), return to zero, and then complete countup. ) Down-count (subtraction) input When counting is set to the subtraction direction, counting will continue until full scale is reached (- with the -digit type and - with the -digit type), and then the display will change to with the -digit type and with the -digit type. The counting value does not become (zero) and so the counter does not count up. ) Directive, independent, and phase inputs The counting value is counted up or down to any number other than once. When it comes to (zero) again, the counter starts counting up. CAUTIS FOR USE For more information regarding the cautions for use of C series counter, refer to page PRECAUTIS IN USING TE C SERIES. Phone:.. - Fax:.. - Web: info@clrwtr.com
7 Operation mode. Input mode For the input mode, you can choose one of the following five modes Addition Subtraction Directive Independent Phase DIR IND PASE C-S Input mode Addition Operation IN or IN works as an input block (gate) for the other input. *Minimum input signal width z:. ms; kz:. ms Example where IN is the counting input and IN is the input block (gate). IN A A A A Blocked IN n- n- n- n n n- n- n- Count-up completed Example where IN is the counting input and IN is the input block (gate). IN Blocked Blocked A A A A Subtraction IN n- n n n- n- n- n- Count-up completed * A must be more than the minimum input signal width. Directive DIR IN is the counting input and IN is the addition or subtraction directive input. IN adds at level and subtracts at level. IN IN Counting A A A A Addition Subtraction Addition * A must be more than the minimum input signal width. IN is addition input and IN is subtraction input. IN Independent IN IND Counting * IN and IN are completely independent, so there is no restriction on signal timing. Addition when the IN phase advances beyond IN, and subtraction when the IN phase advances beyond IN. IN Phase PASE IN Counting Phase advance B B Phase retard * B must be more than the minimum input signal width. Phone:.. - Fax:.. - Web: info@clrwtr.com
8 C-S. Output mode For the output mode, you can choose one of the following seven modes Maintain output/hold count Maintain output/over count I Maintain output/over count II One shot/over count One shot/recount I One shot/recount II One shot/hold count Output mode Maintain output old count OD-A Maintain output Over count I OD-B Maintain output Over count II OD-C One shot Over count SOT-A One shot Recount I SOT-B One shot Recount II SOT-C One shot old count SOT-D OD-A OD-B OD-C SOT-A SOT-B SOT-C SOT-D Operation count-up completion and until resetting. During that time, the count display does not change from that at count-up completion. count-up completion and until resetting. owever, counting is possible despite completion of count-up. count-up completion and until the next signal enters. owever, counting is possible despite completion of countup. count-up completion for one shot output time. Counting is possible despite completion of count-up. count-up completion for one shot output time. Counting is possible despite completion of count-up. owever, reset occurs simultaneous with completion of count-up. While output is being maintained, restarting of the count is not possible count-up completion for one shot output time. Counting is possible despite completion of count-up. owever, reset occurs simultaneous with output. count-up completion for one shot output time. During that time, the count display does not change from that at count-up completion. occurs simultaneous with output. Output control Output control (Example when input mode is either addition or subtraction) n- n- n- n Unable n- n- n n n - - n- n- n n n - - Output control n- n- n n n - - Output control Approx. s n- n- n n- n- (automatic) Output control Output control Output control Approx. s n- n n - n n- Approx. s (automatic) n- n n n- Unable Approx. s (automatic) Phone:.. - Fax:.. - Web: info@clrwtr.com
9 Input connections Signal input type C-S ) Open collector ) For output (PC, sensor etc.) V DC (Photoelectric sensor, proximity sensor, etc.) V DC Output Output -pin type ock Input input Input input V DC output -pin type ock Input input Input V DC input output ) Contact input ) For a rotary encoder Relay, switches etc. B phase A phase V DC -pin type ock Input input Input input -pin type Input Input V DC output Input, input, and reset input specifications Impedance during short-circuit: kω max. (At Ω, the outflow current is approximately ma.) Residual during short-circuit: V max. Impedance when released: kω min. Max. applied : VDC max. ock input specifications Impedance during short-circuit: kω max. (At Ω, the outflow current is approximately. ma.) Residual during short-circuit: V max. Impedance when released: kω min. Max. applied : DVC max. The contact relay should be one which can open/close V,. ma. * There is no V DC with - V DC/ V AC types. ) For a dual-line sensor -pin type Input Input input What is the prescale function? The prescale function converts the count into an actual value (amount) and displays it. Example For a device that outputs pulses when m has been fed:. Set decimal position to the last rd place.. Set the prescale value to. (/). m.ft Dual-line sensor specifications eakage current:. ma max. Breaker capacitance: ma min. Residual :. V max. Usable : Runs on VDC Encoder pulse SET/OCK C Can be set to easy-to-understand unit. Prescale value:. * If a dual-line sensor is connected to a - VDC/ VAC type, VDC (. to. VDC) and VAC (. to. VAC) should be applied to the power supply of the counter. pulses SET/OCK C Phone:.. - Fax:.. - Web: info@clrwtr.com
DIN 48 SIZE LCD ELECTRONIC COUNTER. FEATURES 1. Two-stage presetting (upper and lower limits) SET2 SET1
C4-W DIN SIZE CD EECTRIC COUNTER C4-W U File No.: E CS File No.: R99.89 -pin type.89 64.5.59 mm inch type FETURES. Two-stage presetting (upper and lower limits) Count Output Output SET SET. Bright and
More informationDIN 48 SIZE DIGITAL TIMER. UL File No.: E C-UL File No.: E122222
DIN SIZE DIGIAL L4H/-L imers L4H imers Pin type 4..9 mm inch Screw terminal type RoHS Directive compatibility information http://www.nais-e.com/ UL File No.: E C-UL File No.: E Features. Bright and Easy-to-Read
More informationDIN 48 SIZE DIGITAL TIMER. UL File No.: E C-UL File No.: E122222
DIN SIZE DIGITAL TIME 4..9 mm inch 8-pin type -pin type Screw type Product types UL File No.: E C-UL File No.: E Features Wide time range The operation time range covers from 0.0 sec. to 9999 hours. The
More informationCOMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291
COMP SIZE HIGH PRECISI IMERS VARIOUS OUPU & OPERAI MODE YPES SDX (one) SDX imers Features UL File No.: E22222 CSA File No.: LR3929 3 operation modes added for fuller lineup Now, operation modes include
More informationMULTI-RANGE ANALOG TIMER
MULI-RANGE ANALOG IMER PM4S imers PM4S RoHS Directive compatibility information http://www.nais-e.com/ Features 1. Economic pricing that promptly reflects market demands Remarkable economic pricing is
More informationDigital Counter. DIN 72 x 72 mm Counters with Easy-to-use Functions
Digital Counter DIN 7 x 7 mm Counters with Easy-to-use Functions Designed with an emphasis on ease of operation. All models equipped with prescale function which displays in units of actual physical parameters
More information02/11/2015
17.5 mm - 1 Relay 5A EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer
More informationCount/Time Totalizers
/Time Totalizers Compact or Time Totalizers with Easy-to-Read and NEMA 4 Protection High-visibility, 8.5 mm negative transmissive LCD. NEMA 4 when used in conjunction with Y92S-32 rubber gasket supplied
More informationSolid-state Timer H3DS
Solid-state Timer H3DS DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to 230 VAC/VDC
More informationON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H
Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Solid-state Timer CSM DS_E_
More information05/09/2012
17.5 mm EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer ON LED) Option
More informationNo mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.
Series Digital LCD Timer DIN W48 H48mm Features Power supply : 4-4VAC 5/6Hz, 4-4VDC universal Easy to switch Up/Down mode programmable output modes and timing ranges () Selectable function by front digital
More informationTimers/Time Switches/Counters/Hour Meters
0 0 imers/ime Switches/Counters/Hour Meters MUI-RANGE ANAOG IMER PMS imers PMS Features. Economic pricing that promptly reflects market demands Remarkable economic pricing is implemented in pursuit of
More informationA new approach to static electricity countermeasures
Advanced intelligent Sensors NEW ELECTROSTATIC SENSOR EF-SSERIES A new approach to static electricity countermeasures Measurement of surface potentials while a production line is running Phone: 8.894.42
More informationTimers/Time Switches/Counters/Hour Meters
06 07 Timers/Time Switches/Counters/Hour Meters HOUR METER TH13 TH23 Hour Meters 52 2.047 52 2.047 54 2.126 TH23 series (with reset function) UL File No.: E42876 CSA File No.: LR39291 Features 1. High-performance
More information08/07/2015
17.5 mm - 1 Solid State Relay 0.7A MUS2 Part number 88827004 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external
More informationContents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers
Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2 for Low Voltage, and EMC Directives. Approved by UL and CSA. Lloyds/NK approvals.
More informationSelf-powered Counter
Self-powered Counter Subminiature Totalizing Counter Requires No External Power Supply DIN-sized 48 24 mm Wire-wrap terminal and screw terminal types available. AC/DC voltage, DC voltage, and No-voltage
More informationSolid-State Digital Counter H7AN
Solid-State Digital Counter Preset and Totalizing Counters with Up to 8-Digit LED Displays Draw-out construction allows setting, servicing without disconnecting wiring Choose from selectable UP/DOWN or
More informationModel Number Structure
Total Counter/Time Counter (DIN 72 x 36) CSM DS_E_4_1 DIN 72 x 36-mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 Large, easy-to-read displays:
More informationDIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS
DIN SIZE ANALOG MULI-ANGE CYCLIC WIN IMES UL File No.: E122222 CSA File No.: L39291 FEAUES A single twin timer unit that repeats (variable) ON/OFF. Multiple ranges with a.1 s to 5 h time specification
More informationBulletin 700-HX Multifunction Digital Timing Relay
Bulletin 700-HX Multifunction Digital Timing Relay Model Operating Mode Timing Range Socket Type Contact Output No. of Pins Input Voltage Cat. No. Cat. No. 700 HX A mode: Signal ON-Delay 1 A-1 mode: Signal
More informationModel Number Structure
Total Counter/Time Counter (DIN 72 x 36) CSM DS_E_5_3 DIN 72 x 36-mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 Large, easy-to-read displays:
More informationModel Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models
Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model
More information08/07/2015
17.5 mm - 1 Relay 8A MUR1 Part number 88827105 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external load connection
More informationSolid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A
Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2. Conforms to EMC standards (EN50081-2 and EN50082-2). Approved by UL and CSA. Lloyds/NK
More informationPower source. Input. Contact / Open collector Voltage input (SELECTABLE) AC V DC12-24V AC V. Output indicator
SERIES Electronic Preset Counter Instruction Manual Please note that misuse of this device may lead to injury to the user or damage to the device. Please observe all safety precautions and warnings in
More informationИ М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz
8 Pin Plug Type DIN W48 H48mm 8 Pin Plug Features Upgraded counting speed: 1cps / 3cps / kcps / 5kcps Selectable voltage input (PNP) method or no-voltage input () method Decimal point setting (fixed decimal
More informationCP-T range Benefits and advantages
Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers
More informationCP-E range Benefits and advantages
Benefits and advantages Characteristics Output voltages 5 V, 12 V, 2 V, 8 V DC Adjustable output voltages Benefits Signalling output/contact Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / A / 5 A
More informationSelect G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges
NO: RL-159 PRODUCT: G3PA SSRs, G32A Cartridges DATE: January 2017 TYPE: Partial Discontinuation Notice Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X
More informationSolid-state Twin Timer
Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time
More informationMCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description
Voltage transducer for AC voltages TERFACE Data sheet 006_en_0 PHOENIX CONTACT 00-0- Description The MCR voltage transducer measures AC voltages in several signal ranges from 0... ±4 V AC to 0... ±30 V
More informationSolid-state Timer H3DE
Solid-state Timer H3DE DIN-rail Mounted, Standard 22.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/DC) reduces the number of timer models kept in stock. (except for H3DE-H) 12-VDC
More informationSelf-powered Tachometer
Self-powered Tachometer H7ER Revolutions displayed up to five digits. Dual revolution display accding to encoder resolution used; 1000 s 1 /1000 min 1 1000.0 s 1 /1000.0 min 1 Switchable dual revolution
More informationSPST-NO SPDT DPST-NO DPDT
PCB Relay A Power Relay with Various Models High-sensitivity ( mw) and High-capacity ( A) Models available. Low profile:.7 mm max. in height Conforms to VDE (EN0-), UL and CSA.. Meets EN0- requirements
More informationNPN PNP NPN PNP NPN PNP
Cam Positioner Low-Cost, High-Performance Electronic Cam Switch for Use with OMRON E6F Rotary Encoder Control outputs can be programmed to turn ON/OFF in 1 units of rotary encoder shaft rotation Handles
More informationMultifunctional counter tico 772/773/774
Universally applicable as a tachometer, timer, shift counter, batch counter Easy to operate Four different backlight colours Intensity of backlighting can now be adjusted Large, clearly readable 48 x 48
More information02/11/2015
Emergency stop and safety guard monitoring 1 channel KNAC3-YS Part number 85103035 "Emergency stop" & "Gate monitoring" functions Single channel operation Security with redundancy and feedback circuit
More informationRE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O
Product data sheet Characteristics RE22R2MMU Multifunction Timer Relay - 24VDC/24..240 V AC - 2 C/O Main Range of product Product or component type Discrete output type Device short name Nominal output
More information12 V DC ±10 % 150 ma max. 130 ma max. 120 ma max.
96 PHOTO PHOTO ON/OFF Input SERI Related Information General terms and conditions... F-3 General precautions... P.9 MEASURE panasonic.net/id/pidsx/global Multi-functional D rail mounting slim sensor controller
More informationElectronic timer CT-TGD.22
2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection
More informationRE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal
More informationRE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC
Characteristics off-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal
More informationRelays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.
RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in
More informationDIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure
New Product News Measuring & Monitoring Relays K8AK/K8DS Series DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays Compact 22.5 mm and 17.5 mm housings Resistant to high-frequency
More informationDIN48 SIZE MULTI-RANGE ANALOG TIMER. Protective construction. Time range IP65 IP50 IP selectable ranges 1s to 500h IP50 IP65 IP50
12 Socket mount PRODUC YPE ype 62.5 2.461 Operation mode DIN SIZE MULI-RANGE ANALOG IMER mm inch Flush mount 8 operation modes Pulse -delay Pulse Flicker Pulse -flicker Differential /-delay (1) (2) Signal
More informationIndicator (4digit) (5digit) 8-pin plug counter
8 Pin Plug type DIN W8 H8mm 8 Pin plug counter Features Upgraded counting speed : 1cps / cps / 2kcps / 5kcps Decimal point setting(fixed decimal point of display) Wide range of power : 1-2VAC 5/6Hz 12-2VAC
More informationLED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.
99 PHOTO PHOTO LED Beam Sensor - SERIES Related Information General terms and conditions... P.1 Sensor selection guide...p.11~ / P.~ CA... P.79 ~ General precautions... P.7 Conforming to EMC Directive
More informationNA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation
497 Compact Size Sensor NA-PK SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.59~ Sensor selection guide... P.475~ General precautions...p.5 PHOTO PHOTO Conforming
More informationE2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)
Cylindrical Proximity Sensor in Plastic Housing High quality full body plastic housing for high water proof requirements Polyarylate housing for light chemical resistance Applications Detection of bottle
More information02/11/2015
35 mm - 1 Relay 8A OUR3 Part number 88867103 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external
More informationPreset counters, electronic
The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their
More informationSelf-Powered Counters H7ET
Self-Powered Counters Subminiature Time Totalizers Require No External Power Supply Subminiature 8 x 2 mm (1.89 x.9 in) Improved noise immunity Screw terminal and wire-wrap types available Printed circuit
More informationOvercurrent Protection / 7SJ45
Overcurrent Protection / SJ SIPROTEC easy SJ numerical overcurrent protection relay powered by CTs Fig. / Description SIPROTEC easy SJ numerical overcurrent protection relay powered by current transformers
More informationRE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Control type [Us] rated supply voltage Voltage range Main Range of product Product or component
More informationCount - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2
Selection guide Count - counters Function Totalising counters Display type Mechanical LCD Font panel dimensions (h x w) in mm 0 x 0 x. 0 x 60 x Number of display digits 6 digits or 6 digits (depending
More informationRE17LLBM asymmetrical flashing relay s V AC - solid state output
Characteristics asymmetrical flashing relay - 0.1..1 s - 24..240 V AC - solid state output Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 75.00 USD Main Range
More informationIDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)
IDEC RJ22 Series Slim Relays (Bifurcated Contacts) Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) High contact
More informationMulti Function Timer with Free power, Compact size W38 H42mm
Multi Function with Free power, ompact size W8 H4mm Features Wide power supply range : 100-40VA 50/0Hz, 4-40VD (universal), 4VA 50/0Hz / 4VD (universal), 1VD Various output operations( operation modes)
More informationKNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES
FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs Inputs 10 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate with up to 32 devices DESCRIPTION
More informationElectronic timer CT-SDD.22
CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W
More information02/11/2015
Standstill monitoring KSW3-JS Part number 85102331 Function "Stillstand detection without sensors" Independent of rotation direction Security with redundancy and feedback circuit 3 forcibly guided "NO"
More informationField Network SRT Series
Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Field Network SRT Series
More informationCP-T range Product group picture
Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details
More informationPD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description
Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer
More informationRE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Product availability : Stock - Normally stocked in distribution facility Price* : 42.90 USD Main Range of product Product or component
More informationProcess displays For standard signals, temperature, resistance measurement
Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions
More informationPLC-K506 Series FEATURES DESCRIPTION FEATURES
FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs Inputs 10 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate With Up to 32 Devices DESCRIPTION
More informationTRD-J Series Incremental Encoders
Series Incremental Encoders Features mm thick shaft and ø5 mm body Vibration and shock resistant metal slit plate durable at 1, P/R Operating voltage ranging from 4.75 to 3 VDC Totem-pole output facilitating
More information02/11/2015
"Compact" range with display CD12 Part number 88970041 Green LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Industrial temperature range (-20 C +55 C) Analogue
More informationTwo outputs: contact and non-contact
SRIS Sensor Controller Multi-functional slim sensor controller DI rail mounting Two outputs: contact and non-contact Connects two sensors -C7W Mountable on 3 mm.378 in DI rail by one-push. It reduces mounting
More informationEnergy Management Three-phase energy meter with output modules Type EM4-DIN
Energy Management Three-phase energy meter with output modules Type EM4-DIN Class 1 (active energy) Class 2 (reactive energy) Three-phase multi-function energy meter Back-lighted LCD display 3 1 / 2 DGT
More informationRE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC
Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Product availability : Stock - Normally stocked in distribution facility Price* : 75.00 USD Main Range of product Product
More informationOMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer
OMRON Analog Set Multifunction Timers Series To view data sheets, click on any link below: - Standard Timer -G - Star-Delta Timer -F - Twin Timer -H - Power OFF- Delay Timer Multifunction Timer Analog
More informationOrdering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications
Latching Relay MMK CSM_MMK_DS_E_1_1 Mechanically Latching Relays Based on the MM Power Relay Low power consumption due to mechanical latch for economic operation. Relays with mixed coil specifications
More informationG5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend
PC Power Relay A Miniature Relay with -pole A/5A Switching Capability and 0 kv Impulse Withstand Voltage Highly efficient magnetic circuit for high sensitivity (200 mw). Small, yet provides 0-kV impulse
More informationGEMINI PRESETTABLE DUAL RATE INDICATOR WITH RATIO (A/B)
Bulletin No. GEM5-C Drawing No. LP0321 Released 1/05 GEMINI 5200 - PRESETTABLE DUAL RATE INDICATOR WITH RATIO (A/B)! DIFFERENCE (A-B), OR DRAW [(A-B)/B] INDICATION! 6-DIGIT, 0.56" (14.2 mm) HIGH LED DISPLAY
More information02/11/2015
Emergency stop and safety guard monitoring 2 channels KNE3-YS Part number 85102436 "Emergency stop" & "Safety gates monitoring" functions Single and 2-channel operation Security with redundancy and feedback
More informationElectronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile
More informationTotalizing Counters mini-i
mini-i Type 634/635 Type 634: Counter with high immunity against magnetic interfere Type 635: Counter with high shock stability Miniature size Low power consumption Electrical connections in standard grid
More informationIEC/EN/UL60950 & CE certified, EN55032 Class B
Features Regulated Converter Universal input VAC 3W PCB mount package
More informationParameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption
Features Regulated Converter Universal input VAC 3W PCB mount package
More informationRE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC
Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay
More informationDSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.
15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty
More informationRE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC
Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay
More informationVEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage
More informationPCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US
PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique
More information"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting
Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input
More informationThough the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0.
SERIES Ultra-compact Digital Panel Controller CA Convenient s packed in a small body! Ultra-compact Large display Flexible scaling Conforming to EMC Directive Ultra-compact size of W 48 H 24 D 65.5 mm
More informationParameter Condition Min. Typ. Max. Internal Input Filter. refer to line derating graph on PA-4 115VAC 230VAC 115VAC 230VAC. No load Power Consumption
Features Regulated Converter Universal input 85-35VAC 3W PCB mount package
More informationType: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description
Type: EASY719 DA RC Article.: 274117 Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationCustom "Compact" range with display CD20 Custom Part number
Custom "Compact" range with display CD20 Custom Part number 88974051 "Modular" versions designed for Custom application-specific functions (Custom functions) LCD with 4 lines of 18 characters and configurable
More informationEnergy Management Energy Meter Type EM110
Energy Management Energy Meter Type EM110 Single phase energy meter Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Electro-mechanical display Energy readout on display: 6+1 digit
More informationSIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay
Overcurrent Protection / 7SJ46 SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay Function overview Fig. /11 Description The SIPROTEC easy 7SJ46 is a numerical overcurrent protection relay which
More informationLOW-PROFILE SURFACE-MOUNT RELAY. Characteristics. Initial breakdown voltage. Initial surge voltage. Temperature rise* 2 (at 20 C) Max.
TESTING LOW-PROFILE SURFACE-MOUNT RELAY RELAYS 5.6. mm inch FEATURES Low-profile: 6 mm.36 inch in height comforming to EIA standards (Tape height: max. 6.5 mm.56 inch ) Tape and reel package is available
More informationPower supply CP-T 48/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationVoltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationEfficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.
Features Regulated Converter Universal Input VAC 3W PCB Mount Package