И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz
|
|
- Veronica Martin
- 5 years ago
- Views:
Transcription
1 8 Pin Plug Type DIN W48 H48mm 8 Pin Plug Features Upgraded counting speed: 1cps / 3cps / kcps / 5kcps Selectable voltage input (PNP) method or no-voltage input () method Decimal point setting (fixed decimal point of display) Wide range of power supply : 1-4VAC 5/6Hz, 4VAC 5/6Hz, 4-48VDC universal Memory protection for 1years (using non-volatile semiconductor) Selectable Up/Down for counting value Built-in Microprocessor Please read Safety considerations in operation manual before using. Ordering Information FS 4 1P 4 Specifications supply И М 4VAC 5/6Hz, 4-48VDC 4 1-4VAC 5/6Hz 1P 1-stage setting 출력회로의수 I Indicator digit (4-digit) (5-digit) Item FS 8-pin plug counter Sockets (PG-8, PS-8) are sold separately. Shaded parts( ) are changed and added functions from previous FS Series. Model 1-stage setting FS4-1P FS4-1P4 - Indicator - - FS5-I4 digit 4-digit 5-digit Character size (W H) mm 4 8mm supply 4VAC~ 5/6Hz, 4-48VDCЗ 1-4VAC~ 5/6Hz Permissible voltage range 9 to 11% of rated voltage consumption Max. 3.5VA (4VAC~ 5/6Hz), Max. 4.6VA Max. 3.8VA Max..3W (4-48VDCЗ) (1-4VAC~ 5/6Hz) (1-4VAC~ 5/6Hz) for Selectable 1cps/3cps/kcps/5kcps (DIP switch) Return time Max. 5ms Min. signal width : approx. ms Selectable voltage input (PNP) method or no-voltage input () method Input method [Voltage input (PNP) method]-input impedance: max. 1.8kΩ, [H]: 5-3VDCЗ, [L]: -VDC [No-voltage input () method]-short-circuit impedance: max. 47Ω, short-circuit residual voltage: max. 1VDC, open-circuit impedance: min. 1kΩ One-shot output time.5 to 5 sec Control Type Instantaneous SPST (1a) Contact output Capacity 5VAC~ 3A resistive load - Relay Mechanical Min. 5,, operations life cycle Electrical Min. 1, operations (5VAC 3A resistive load) Insulation resistance Over 1MΩ (at 5VDC megger) External power supply Max. 1VDCЗ ±1% 5mA Memory retention Approx. 1 years (non-volatile memory) Dielectric strength,vac 5/6Hz for 1 min (between all terminals and case) Noise AC voltage ±kv the square wave noise (pulse width 1μs) by noise simulator immunity AC/DC voltage ±5V the square wave noise (pulse width 1μs) by noise simulator Vibration Mechanical.75mm amplitude at frequency 1 to 55Hz (for 1 min) in each X, Y, Z direction for 1 hour Malfunction.5mm amplitude at frequency 1 to 55Hz (for 1 min) in each X, Y, Z direction for 1 minutes Shock Mechanical 3m/s (approx. 3G) in each X, Y, Z direction for 3 times Malfunction 1m/s (approx. 1G) in each X, Y, Z direction for 3 times Environment Ambient temp. -1 to 55, storage: -5 to 65 Ambient humi. 35 to 85%RH, storage: 35 to 85%RH Protection structure IP (front part, IEC standard) Approval И М Weight 1 Approx. 13g (approx. 9g) Approx. 1g (approx. 8g) 1: The weight includes packaging. The weight in parenthesis is for unit only. Environment resistance is rated at no freezing or condensation. Distribution SSRs / s Mode & s J-59
2 Connections FS4-1P4 PNP 1VDC 5mA FS4-1P PNP 1VDC 5mA FS5-I4 PNP 1VDC 5mA VDC CTACT: 5VAC 3A RESISTIVE LOAD VDC CTACT: 5VAC 3A RESISTIVE LOAD VDC 1-4VAC 5/6Hz 4.6VA 4VAC 5/6Hz 3.5VA 4-48VDC.3W 1-4VAC 5/6Hz 3.8VA Input Connections Voltage input (PNP) Solid-state input (standard sensor: PNP output type sensor) Contact input Counte 1.8kΩ V (PNP output), input part 1.8kΩ V (PNP open collector output) 1.8kΩ V Counting speed : Set as 1 or 3cps No-voltage input () Solid-state input (standard sensor: output type sensor) Contact input V ( output) ( open collector output) Counting speed : Set as 1 or 3cps, input part V V Input & output connections 1VDC PR18-5DN GND Total value of load capacity and current consumption should not be exceed current capacity (max. 1VDC 5mA) SOURCE 6 7 Load Please select proper capacity of load not to exceed contact capacity. Contact capacity: max. 5VAC 3A Contact type: 1a J-6
3 8 Pin Plug Type Dimensions Nameplate design is changed and rear length is shorten than previous. Bracket (unit: mm) cut-out Min. 65 Min Socket (sold separately) PG PS Distribution SSRs / -Ø Ø s 4 DIP Switch Input logic (, input) (no-voltage input) 1 PNP (voltage input) operation mode N. C (not used) Up/Down mode 1 Input logic (/PNP) 6 SW Factory default 1: Indicator model (FS5-I4) does not have no. 1,, 3 DIP switch of SW for output operation mode setting. Mode & s Up/Down mode Down mode Up mode No memory backup 6 1cps 3cps kcps 5kcps J-61
4 Counting Operation For Indicator (FS5-I4) Up mode Down mode +Max. display value +Max. display value -Max. display value - display is only for F, K, Q, S output operation mode and it cannot be set. Operation Mode One-shot output (.5 to 5 sec) Self-holding output mode (SW) F Up mode Down mode Operation increases or decreases until reset signal input is applied and self-holding output is maintained. N and self-holding output are maintained until reset signal input is applied. C When count-up, counting display value is reset and it counts simultaneously. R is reset after one-shot output time and it counts simultaneously. K increases or decreases until reset signal input is applied. P is maintained while output is. Counting value is internally reset and it counts simultaneously. Q increases or decreases during one-shot output time. S Set one-shot output time by front TIME volume switch. maintains when counting display value is larger or equal than setting value. J-6
5 8 Pin Plug Type Dot For Decimal Point 3 sec RUN mode DP 3 sec mode In run mode, hold the key for over 3 sec, and it enters setting mode [DP]. In setting mode, hold the key for over 3 sec, and it saves the setting and returns to RUN mode. If there is no key input for 6 sec when entering setting mode, it returns to RUN mode Set decimal point by front Proper Usage Reset function Reset After DIP switch setting when cutting off the power, press the front key or supplying the external reset. If reset is not executed, the counter will be working as previous mode. The Reset signal width It is reset perfectly when the reset signal is applied for max. ms regardless of the contact input & solid-state input. 1 Reset input 1: In case of a contact reset, it is reset perfectly if the time of reset signal is applied during min. ms even though chattering occurs. : It can be input the signal of CP1&CP after min. 5ms from closing time of reset signal. power The power 1VDC which is provided to sensor is built in it. Please use it under max. DC5mA. Min. signal width : Please make duty ratio (/) 1:1. 1cps: Min..5sec : Min. signal width 3cps: Min.16.7ms kcps: Min..5ms 5kcps: Min..1ms Detaching Case Push the grooves at both side of the unit with a flat head driver to the outside and push the plug part to the front. The plug is detached. Be sure not to be wounded when using a tool. This is a response speed per 1 sec when the duty ratio (:) of input signal is 1:1. If the duty ratio is not 1:1, the width between and should be over min. signal width and the response speed is getting slower against input signal. If either or signal is shorter than minimum signal width, this product may not respond. Ta Tb 3 Ta Therefore Ta ( width) and Tb ( width) needed to be over min. signal width. is 1/ value of rated spec. when duty ratio is 1:3. It can not respond if it is smaller than min. signal width (Ta). In case of 4VAC, 4-48VDC model, power supply should be insulated and limited voltage/current or Class, SELV power supply device. The inner circuit voltage rises within 1ms after supplying the power to the unit. The input may be unavailable at this period. Be sure that the inner circuit voltage drops within 5ms after turning the power. Error Error Troubleshooting ERR value is. Change the setting value anything but. If error occurs, the output turns. Indicator model does not have error display function. 1ms Unstable time for input signal 5ms Use the unit within the rated power supply. When supplying or cutting the power, use a switch not to occur chattering. Distribution SSRs / s Mode & s Push the plug to the front. Turn the power before detaching the case. J-63
Indicator (4digit) (5digit) 8-pin plug counter
8 Pin Plug type DIN W8 H8mm 8 Pin plug counter Features Upgraded counting speed : 1cps / cps / 2kcps / 5kcps Decimal point setting(fixed decimal point of display) Wide range of power : 1-2VAC 5/6Hz 12-2VAC
More informationNo mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.
Series Digital LCD Timer DIN W48 H48mm Features Power supply : 4-4VAC 5/6Hz, 4-4VDC universal Easy to switch Up/Down mode programmable output modes and timing ranges () Selectable function by front digital
More informationModel Display digit Size Output Power supply 24VAC 50/60Hz, 24-48VDC 9999 (4-digit) 1-stage setting
FXY Series DIN W7 6mm Of er/timer With Idicatio Oly Features ig speed: cps/cps/kcps/kcps Selectable voltage iput (PNP) method or o-voltage iput (NPN) method Iput mode: Up, Dow, Dow Dot for Decimal Poit
More informationNew 1. Temperature unit P J K R. N Indicator. X 12-24VDC VAC 50/60Hz. Indicator Alarm/Sub output. I Indicator
T3 / T4 Series Features Various size as DIN specifications (W H24, W72 H36, W96 H, W H, W H96, W72 H72, W96 H96mm) Please read Safety Considerations in operation manual before using. Ordering Information
More informationTA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C
T Series nalog nd Non-Indicating Type, PID Control, Set y Dial Features Improved control performance with built-in microcomputer dopting new uto-tuning PID control algorithm : Selectable ON/OFF, PID control
More informationMulti Function Timer with Free power, Compact size W38 H42mm
Multi Function with Free power, ompact size W8 H4mm Features Wide power supply range : 100-40VA 50/0Hz, 4-40VD (universal), 4VA 50/0Hz / 4VD (universal), 1VD Various output operations( operation modes)
More informationTA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C
nalog nd Non-Indicating Type, PID Control, Set Temperature y Dial Features Improved control performance with built-in microcomputer dopting new uto-tuning PID control algorithm : Selectable ON/OFF, PID
More informationNo mark VAC 50/60Hz, VDC 1 12VDC 2 24VAC 50/60Hz, 24VDC. selectable by output operation mode
TN Series DN W48 H48mm, Universal Voltage Multi-unction Timer eatures Realization of wide range of power supply :100-40V 50/0Hz, 4-40VD universal, 4V 50/0Hz, 4VD universal, 1VD Various output operation
More informationSolid-State Digital Counter H7AN
Solid-State Digital Counter Preset and Totalizing Counters with Up to 8-Digit LED Displays Draw-out construction allows setting, servicing without disconnecting wiring Choose from selectable UP/DOWN or
More informationCount/Time Totalizers
/Time Totalizers Compact or Time Totalizers with Easy-to-Read and NEMA 4 Protection High-visibility, 8.5 mm negative transmissive LCD. NEMA 4 when used in conjunction with Y92S-32 rubber gasket supplied
More informationCylindrical type proximity sensor
Cylindrical type Cylindrical type proximity Features Improved the noise resistance with dedicated IC Built-in reverse polarity protection circuit (DC 3-wire type) Built-in surge protection circuit Built-in
More informationNo mark Time-limit contact 1c Time-limit contact 2c,Time-limit contact A 1c+Instantaneous contact 1c(selectable) DIN W48 H48mm (4digit)
DIN W48 H48mm Digital backlight LCD timer Features Upgraded Features Mounting space saving with compact design : downsized by approx. % in depth compared to existing ls (length of panel on the back side
More informationNo-mark 12-24VDC X 1. Multi-input mode. DIN W72 H36mm DIN W96 H48mm (5digit) D Display Unit
5Y/5W Series Panel Mounting Type, 5 igit isplay Unit Upgraded isplay Unit from Y, W Features Various input specifications : Stic Parallel input, ynamic Parallel input, /5 bit serial input, 6//5 bit serial
More informationDIN W48 H24mm, W72 H36mm Loop powered digital scaling meter [M4NS/M4YS Series]
DIN W48 H24mm, W72 H36mm Loop powered digital scaling [M4NS/M4YS Series] M 4 N S N A supply Measuring function Measuring input range A N S DC4-20mA Loop powered type Scaling N DIN W48 H24mm Y DIN W72 H36mm
More informationSelf-Powered Counters H7ET
Self-Powered Counters Subminiature Time Totalizers Require No External Power Supply Subminiature 8 x 2 mm (1.89 x.9 in) Improved noise immunity Screw terminal and wire-wrap types available Printed circuit
More informationHigh Speed Response Type With Built-in Output Protection Circuit
High Speed Response Type With Builtin Output Protection Circuit Features Reverse power polarity and overcurrent High speed response: Max. ms ight /Dark mode selectable by control wire Builtin the sensitivity
More informationAnalog Timer TTL Series
Analog r TTL Series Part Number Description TTL - ❶ ❷ ❸ ❶ Pin Type 8 : 8Pin Socket and Panel mounted ❷ Timing Mode A : A, A1, F1, I B : A, A1, B, F ❸ Supply Voltage 110/220VAC 24VDC 110VDC General Specification
More informationHigh Speed Response Type With Built-in Output Protection Circuit
Amplifier Builtin Type By Side High Speed Response Type With Builtin Output Protection Circuit Features Reverse power polarity and overcurrent High speed response: Max. ms ight /Dark mode selectable by
More informationContents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers
Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2 for Low Voltage, and EMC Directives. Approved by UL and CSA. Lloyds/NK approvals.
More informationSolid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A
Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2. Conforms to EMC standards (EN50081-2 and EN50082-2). Approved by UL and CSA. Lloyds/NK
More informationFuzzy Temperature Controllers E5AF
Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate
More informationSolid-state Timer H3DS
Solid-state Timer H3DS DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to 230 VAC/VDC
More informationTimers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range
GT3A Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEDs UL,
More informationAPPENDIX APPENDIX A 1
A 1 SPECIFICATIONS Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 7VA 4VA/2.5W Sensor input Thermocouple
More informationCompoBus/D-type Digital Controller
CompoBus/D-type Digital Controller Digital Controller for the CompoBus/D and Conforming the DeviceNet Conforms the DeviceNet and connects a Programmable Controller without any programming. High performance
More informationDigital Counter. DIN 72 x 72 mm Counters with Easy-to-use Functions
Digital Counter DIN 7 x 7 mm Counters with Easy-to-use Functions Designed with an emphasis on ease of operation. All models equipped with prescale function which displays in units of actual physical parameters
More informationSelf-powered Counter
Self-powered Counter Subminiature Totalizing Counter Requires No External Power Supply DIN-sized 48 24 mm Wire-wrap terminal and screw terminal types available. AC/DC voltage, DC voltage, and No-voltage
More informationHPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier
Ultraminiature Photoelectric Sensors with Self-contained Amplifier HPJSeries HPJ Fingertip-size, Provided with a various slit attachments. (six types) Fingertip-size 22 x 11 x 8mm (thru scan model) 30
More informationArea sensor with plastic case
Area Area with plastic case Features mm slim body with fresnel lens Adoption of plastic(pc/abs) injection case Various functions; stop transmission, interference prevention, ening/flashing JOB indicator,
More informationTA Series. Analog Setting Non-Indicating type, PID Control. Analog and non-indicating type, PID control, set temperature by dial.
nalog and non-indicating type, PID control, set temperature by dial Features Improved control performance with built-in microcomputer dopting new uto-tuning PID control algorithm : Selectable ON/OFF, PID
More information12 V DC ±10 % 150 ma max. 130 ma max. 120 ma max.
96 PHOTO PHOTO ON/OFF Input SERI Related Information General terms and conditions... F-3 General precautions... P.9 MEASURE panasonic.net/id/pidsx/global Multi-functional D rail mounting slim sensor controller
More informationOpaque materials of Min. Ø60mm. Hysteresis - Max. 10% at rated setting distance
Small and light, common type Features Easy to mount at a narrow space with small size and light weight. Convenient to adjust the sensitivity by external sensitivity adjustment control.(diffuse reflective
More informationModel Number Structure
Total Counter/Time Counter (DIN 72 x 36) CSM DS_E_4_1 DIN 72 x 36-mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 Large, easy-to-read displays:
More informationY Type. W Type. AC voltage AC current
Multi Meter DIN W72 36mm, W96 48mm, Digital Multi Meter Features Super version of panel meter Various output options (Default: Indicator) RS485 Communication output, Low speed serial output, Current (4-20mA),
More informationBulletin 700-HX Multifunction Digital Timing Relay
Bulletin 700-HX Multifunction Digital Timing Relay Model Operating Mode Timing Range Socket Type Contact Output No. of Pins Input Voltage Cat. No. Cat. No. 700 HX A mode: Signal ON-Delay 1 A-1 mode: Signal
More informationTimers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.
GT3A GT3A Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEDs
More informationModel Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models
Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model
More informationT3S/ T3H/ T4M/ T4L. Digital switch setting type. Features. Ordering information T 3 S B 4 R P 4 C
/ T3/ / T4 Digital switch setting type Features Various size by DIN specification (W48 48, W48 96, W7 7, W96 96mm) ccuracy: F.S. ±.5%(Except ) Free : Series Ordering information T 3 S 4 R 4 Unit range
More informationPCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load
PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks -A Load Compact: 20 x 15 x 10 mm (L x W x H). Low power consumption: 200 mw. Flux protection or plastic-sealed construction available.
More informationOrdering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications
Latching Relay MMK CSM_MMK_DS_E_1_1 Mechanically Latching Relays Based on the MM Power Relay Low power consumption due to mechanical latch for economic operation. Relays with mixed coil specifications
More informationTimers GE1A. GE1A Series ON Delay Timers Single Function
Key features: DPDT or SPDT + instantaneous SPDT 8-pin, octal base 8 time ranges Repeat error ±0.2% maximum Large, clear knob for easy setting Instant monitoring of operational status by LED indicators
More informationTemperature Controllers E5 J
Temperature Controllers Advanced PID Controller with Fuzzy Logic-Based Adaptive Tuning Provides Optimum Performance Available in 3 standard DIN sizes: Choose 1/4, 1/8 and 1/16 DIN Fuzzy adaptive tuning
More informationM4Y/M4W/M5W/M4M Series
MY/MW/MW/MM Series DN W Hmm, W9 Hmm, W Hmm Digital panel for measuring ampere Features Max. display: 9999(MW), 999(Others) Auto zero function or hold function(except for MW) RMS/AVG value selection function(ac
More informationModel Number Structure
Total Counter/Time Counter (DIN 72 x 36) CSM DS_E_5_3 DIN 72 x 36-mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 Large, easy-to-read displays:
More informationSupply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000
Incremental 60-mm-dia. Rotary Encoder E6F-C The Strongest Shaft for Tough Jobs The strongest shaft of any OMRON Incremental Encoder (120 N in the radial direction and 50 N in the thrust direction). Water-
More informationField Network SRT Series
Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Field Network SRT Series
More informationELECTRONIC COUNTER (with pre-scaling function) UL File No.: E C-UL File No.: E122222
EECTRIC (with pre-scaling function) C-S Counters C-S -digit type -digit type pin type type U File No.: E C-U File No.: E Features. Bright and Easy-to-Read Display A brand new bright -color backlight CD
More informationCompact Preset Counter
signo 721 Compact Preset Counter 1 or 2 presets Prescaler with output for connection of a totalizing counter Large, 5-digit LD display Connection by plug-in screw terminals Variety of programming possibilities
More informationMK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure
General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E 1 New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator
More information05/09/2012
17.5 mm EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer ON LED) Option
More informationRatchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj
Ratchet Relay Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation Each contact in the double-pole contact mechanism performs alternate make-brake operation at each pulse input
More informationTwo-way Action Test Button (Models with Lockable Test Button) For Momentary Operation
General Purpose Relays MKS Exceptionally Reliable General Purpose Relay now available with Lockable Test Button IEC Rating of A 0 V AC 0/0 Hz, General use 100,000 cycles. Mechanical indicator standard
More informationSolid-state Twin Timer
Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time
More informationMICRO-CONTROLLER X (48mm 48mm)
PX series Digital temperature Ctroller DATA SHEET Socket Type With frt dimensis of 48 48mm, this socket type temperature ctroller enables On-Off ctrol, PID ctrol or 8-step ramp/soak functi, using thermocouple,
More informationSelect G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges
NO: RL-159 PRODUCT: G3PA SSRs, G32A Cartridges DATE: January 2017 TYPE: Partial Discontinuation Notice Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X
More informationDigital Controller Intelligent, User-friendly Digital Controller and Programmer Controlled with ease with a support software which is input via the communication jack on the front panel. Minute adjustment
More informationDIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure
New Product News Measuring & Monitoring Relays K8AK/K8DS Series DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays Compact 22.5 mm and 17.5 mm housings Resistant to high-frequency
More informationSolid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval
Solid-State Timer Analog Set Multifunction Timers in Slim Design for Track Mounting All settings are made though front panel Six operating modes in a single timer provides flexibility for many applications
More informationOrdering Information. Stepping Relay Unit G9B. Model Number Legend
Stepping Relay Unit CSM DS_E_4_1 Ideal for Controlling Pumps and Production Lines with Six or Twelve Stepping Circuits Built-in relays switch 2 A at 250 VAC or 30 VDC. Initialization of stepping with reset
More informationHigh Reliability Of Fiber Optic Amplifier For Convenient Mounting
Amplifier Reliability Of Amplifier For Convenient Mounting Features speed response: Max. 0.5ms Auto (Button setting)/remote synchronization input, mutual interference protection, selfdiagnosis Reverse
More informationCommunication Ethernet communication (TCP/IP) 8 8mm 16 16mm 25 25mm W. White R. Red G. Green. Blue M G V. Effective focal length
VG Series Features Light integrated vision sensor Minimized image distortion with global shutter method Proprietary technology to block optical interference to improve optical performance (patent) Stronger
More informationPulse Scaler for DIN Rail Attachment
Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary
More informationFeatures. Panel Meters with Advanced Signal Processing Capabilities K3HB
Panel Meters with Advanced Signal Processing Capabilities K3HB K3HB-X/Process Indicator K3HB-V/Weighing Indicator K3HB-H/Temperature Indicator K3HB-S/Linear Sensor Indicator Features Red-Green Display
More informationMINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R
MINIATURE POWER RELAY IN DS RELAY SERIES DSP- RELAYS DSPa DSP SPECIFICATIONS.. DSPa Coil (polarized) (at C F) Minimum mw power coil latching mw mw power coil latching mw.... Contact Arrangement a ab a
More informationModel Number Structure
Digital Controller CSM DS_E_3_1 Advanced Digital Controllers Ideal for Worldwide Use Modular structure High-accuracy: 100 ms sampling (for analog input) Auto-tuning and fuzzy self-tuning Conforms to international
More informationUltraminiature Photoelectric Switches with Self-contained Amplifier
Ultraminiature Photoelectric Switches with Self-contained Amplifier HPJ Series Fingertip-size, Provided with a various slit attachments. (six types) Fingertip-size 22 x 11 x 8 mm (thru scan model) 30 x
More informationSolid-state Timer H3DE
Solid-state Timer H3DE DIN-rail Mounted, Standard 22.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/DC) reduces the number of timer models kept in stock. (except for H3DE-H) 12-VDC
More information02/11/2015
17.5 mm - 1 Relay 5A EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer
More informationPosition Indicator with/without Limit Values
.1 Position Indicator with/without Limit Values Large, 6-digit, 14 mm high LED display Prescaler 2 variable limit values Eeasy direct selection by 2 function keys Rrelay output with two change-over contacts
More informationSPST-NO SPDT DPST-NO DPDT
PCB Relay A Power Relay with Various Models High-sensitivity ( mw) and High-capacity ( A) Models available. Low profile:.7 mm max. in height Conforms to VDE (EN0-), UL and CSA.. Meets EN0- requirements
More information6mm Interface Relays RV8 Series
6mm Interface Relays RV8 Series PRODUCT DESCRIPTION Electromechanical C1D2 (screw terminal) Solid State (spring clamp) IDEC 6mm interface relays provide a compact solution for general purpose relay requirements.
More informationDigital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)
Digital Panel Meter Subminiature Digital Panel Meter that Accepts DC Input Ultra-compact DIN-size (48 x 24 (W x H)) body. Mounting thickness of only 2 mm required. Highly visible display with 10.2-mm-high
More informationDigital Temperature Controller
www.hynux.com Digital Temperature Controller Economical price Convenient functions High speed sampling High accuracy temperature controlling AX2 AX3 AX4 AX7 AX9 Actualized the highly accurate temperature
More informationSolid-state Timer. Operation/resetting system Time-limit contact Time ranges Model
Solid-state Timer PCB-mounting Time Unit for High-frequency Applications Ideal for high-frequency applications with 1-ms reset time (including during operation) either for power resets or external resets.
More informationPower supply voltage Output configuration Output code Resolution (pulses/rotation) Connection method Model
60-mm-dia. Encoder Rugged Encoder for High-precision Detection of Automatic Machine Timing Rugged construction with the highest shaft loading. Radial: 120 N, Thrust: 50 N IP65f water- and oil-proof construction.
More informationTimers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -
Key features: True power OFF-delay up to minutes No external control switch necessary Available with reset inputs Mountable in sockets or flush panel Specifications Operation UL, c-ul Listed File No. E55996
More informationTwo outputs: contact and non-contact
SRIS Sensor Controller Multi-functional slim sensor controller DI rail mounting Two outputs: contact and non-contact Connects two sensors -C7W Mountable on 3 mm.378 in DI rail by one-push. It reduces mounting
More informationD7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information
with Linear Output or Manual Setting Detects Changes in Machine ON/OFF output can be set and checked quickly and easily from the vibration level meter. waveforms can be checked using the AC monitor output.
More informationHG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS
20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,
More informationType Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1
Slim Relays with Forcibly Guided Contacts Conforming to EN Standards EN50205 Class A, approved by VDE. Ideal for use in safety circuits in production machinery. Four-pole and six-pole Relays are available.
More informationON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H
Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Solid-state Timer CSM DS_E_
More informationPA-850 PRESSURE TRANSDUCERS WITH AMP. PA R - N R2 FEATURES MODEL NUMBER DESIGNATION
INTERNAL STRUCTURE (R 1/4) 4 1 2 3 Part name Material 1 2 FEATURES 3 4 Stainless steel diaphragm ABS (Acrylonitrile butadiene styrene) + PC (Polycarbonate) High corrosion resistance and drip-proof construction
More informationPCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US
PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique
More informationJRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)
Plug-in Signal Conditioners M-UNIT ENCODER POSITI TRANSMITTER (field-programmable; built-in excitation) MODEL JRQ MODEL & SUFFIX CODE SELECTI JRQ MODEL SELECTI Open collector Voltage pulse RS- line driver
More informationMultifunctional counter tico 772/773/774
Universally applicable as a tachometer, timer, shift counter, batch counter Easy to operate Four different backlight colours Intensity of backlighting can now be adjusted Large, clearly readable 48 x 48
More informationMODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series
Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation
More information3. Contact Form A: SPST-NO
0 A Compact and high power latching relay High power switching: 0 A, 6 VAC Compact size: mm mm mm Low temperature-rise High overcurrent capability, conforming to IEC6055- UC RoHS Compliant Model Number
More informationPower PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).
Power PCB Relay Subminiature 20 L x 9.90 W x 9.90 H mm (0.79 L x 0.39 W x 0.39 H in) Low power consumption (200 mw) Sealed construction permits automatic soldering and cleaning of the PC board High-capacity
More informationMOS FET Relay. Ordering Information. SSR for Switching Analog Signals, with an Insulation Value of 2.5 kvac between Input and Output Terminals
MOS FET Relay GVM SSR for Switching Analog Signals, with an Insulation Value of. kvac between Input and Output Terminals Switching minute analog signals. Linear voltage and characteristics. Switching AC
More information8 A MINIATURE POWER RELAY IN DS RELAY SERIES
DSP A MINIATURE POWER RELAY IN DS RELAY SERIES DSP RELAYS DSPa.. DSPa.. DSP.. RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Power types added to DS relay series High switching
More informationDigital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE
Digital Panel Meter K3TE Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display with
More informationMonitoring voltages of 3-phase 4 wires with a single unit
VOLTAGE RELAY PTS TYPE High-performance under-voltage relay that activates output when all 3-phase voltages fall below a reference voltage by monitoring voltage on each phase of 4 wires FEATURES Monitoring
More informationNPN PNP NPN PNP NPN PNP
Cam Positioner Low-Cost, High-Performance Electronic Cam Switch for Use with OMRON E6F Rotary Encoder Control outputs can be programmed to turn ON/OFF in 1 units of rotary encoder shaft rotation Handles
More information8 A MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES
A MINIATURE POWER RELAY IN DS RELAY SERIES DSP RELAYS FEATURES DSPa.. DSPa DSP.... Power types added to DS relay series High switching capacity: a: A V AC / ab, a: A V AC High sensitivity: mw pick-up power
More informationIDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)
IDEC RJ22 Series Slim Relays (Bifurcated Contacts) Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) High contact
More information1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01
Monitoring Relays -Phase True RMS AC/DC Over and Under Current Types DIC0, PIC0 DIC0 PIC0 TRMS AC/DC over + under, over+over, under+under current and voltage monitoring relays DC process signal plus/minus
More information08/07/2015
17.5 mm - 1 Relay 8A MUR1 Part number 88827105 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external load connection
More informationTheta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.
Technical Data Sheet Theta 60R 60 R 60 R Fig. Theta R, channel version, in housing S7 clipped on to a top - hat rail. Fig. Theta R, channel version, in housing S7 hole mounting brackets pulled out. Theta
More informationSeries 10-ZSE30A(F)/10-ISE30A
Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High-Precision Digital Pressure Switch Clean series For positive For vacuum/ compound Rated range ISEA 0.1 to 1 MPa How to Order 10 ISEA 01 N M 01 N01 C4H
More informationDigital Indicators K3HB Series
Digital Indicators K3HB Series Distinct by Design, Distinguished in Performance K3HB-H K3HB-S K3HB-X K3HB-V P Zero P Zero H Features Red-Green Display Allows Easy Recognition of Judgment Results The measurement