Section. Timers. Selection Guide... G-2. Timing Diagrams Overview... G-4. W G RTE Series Analog Timers... G-8 Accessories... G-11 Dimensions...

Size: px
Start display at page:

Download "Section. Timers. Selection Guide... G-2. Timing Diagrams Overview... G-4. W G RTE Series Analog Timers... G-8 Accessories... G-11 Dimensions..."

Transcription

1 Selection uide iming Diagrams Overview N! W RE Series Analog NE ESI Accessories D Dimensions A Series Analog D Series Digital F Series rue OFF Delay S Series Star Delta. -! W INW Series Dual Range - E N ES D Series Accessories Dimensions E1A Series ON Delay. -57 Accessories Dimensions P Series ON Delay. -1 Accessories Dimensions Y Series ON Delay. - Accessories Dimensions Instructions for All r Series Section

2 Selection uide Selection uide Selection uide: RE, A, D, and F Series NEW DESIN! Series Model RE A D F Page Appearance Mode of ON-delay Interval OFF-delay One-shot Cycle (ON first) Cycle (OFF first) Signal OFF delay Signal ON/OFF delay ON-delay Interval OFF-delay One-shot Cycle (off first) Cycle (on first) Signal OFF delay Signal ON/OFF delay ON-delay Interval One-shot One-shot ON delay Cycle Signal OFF delay Signal ON/OFF delay rue OFF-delay Range 0.1 second to 00 hrs 0.05 second to 10 hrs 0.01 second to 99.9 hrs 0.05 to 00 seconds Configuration DPD SPD, DPD SPD, DPD SPD, DPD Repeat Accuracy ±0.5% maximum ±0.% maximum ±0.% maximum ±0.% maximum Load Rating (resistive) Available Operating Voltage Approvals A, 0V AC 0-0V AC 1V DC V AC/DC UL Listed c-ul Listed UV CE SPD: A, 50V AC DPD: 5A, 0V AC 0 to 0V AC 1V DC V AC/DC UL Listed c-ul Listed CE SPD: A, 50V AC DPD: 5A, 0V AC 0 to 0V AC V AC/DC UL recognized UV CSA CE 5A, 50V AC 0 to 0V AC V AC/DC UL Listed c-ul Listed CE 1. For iming Diagrams Overview, see page -.. For all series specific instructions, accessories, and dimensions, see the individual series section. - USA: (00) -IDEC or (0) , Canada () 17-IDEC

3 Selection uide Selection uide Selection uide: S, W, E1A, 5P, and 5Y Series NEW DESIN! Series Model Page S W E1A 5P 5Y Mode of Star-Delta Sequential start ON-delay Recycler & instantaneous Recycler OFF start Recycler ON start Interval Interval ON delay Sequential interval ON-delay ON-delay ON-delay Range Star side: 0.05s to 0s Star-delta Switching : 0.05, 0.1, 0.5, 0.5 seconds 0.1s to 00 hrs 0.1s to hrs 0.1s to minutes 0.1s to 1 hour Configuration SPS-NO DPD SPD, DPD SPD DPD, PD Repeat Accuracy ±0.% maximum ±0.% maximum ±0.% maximum ±0.% maximum ±0.% maximum Load Rating (resistive) 5A, 50V AC/0VDC A, 50V AC 5A, V AC/0V DC 5A, 0V AC 5A, 50V AC 5A, DPD: 50V AC A, PD: 50V AC Available Operating Voltage 0 to 0V AC 0 to 0V AC 1V DC V AC/DC V AC/DC 1 to V AC 0 to 0V AC 0 to V AC 00 to 0V AC 1V DC V DC 0 to V AC 00 to 0V AC 1V DC V DC V AC Approvals UL Listed c-ul Listed CE UL Listed c-ul Listed CE UL Listed c-ul Listed UV CE UL recognized UV CSA CE UL Listed c-ul Listed CE Appearance USA: (00) -IDEC or (0) , Canada () 17-IDEC - 1. For iming Diagrams Overview, see page -.. For all series specific instructions, accessories, and dimensions, see the individual series section.

4 iming Diagrams Overview iming Diagrams Overview uide to Reading iming Function Diagrams Applied Start erminals Shorted Start erminals Opened Removed r Signal NO NC NO Closes NC Opens r Begins Counting 1. If power is disconnected during actual timing, most electronic timers reset to the preset time, ready for the re-application of supply voltage (except for F true OFF Delay ).. NO = Normally open.. NC = Normally closed. iming Function Diagrams Overview ON-Delay 1 (power start) When voltage is applied to the coil, the relay contacts remain in the off state and the set time begins. When the set time has elapsed, the relay contacts transfer to the on state. he contacts remain in the on state until the timer is reset. he timer is reset by removing the coil voltage. Applicable models: RE- P(B)1, A-1, -, -, D-1, -, -, -, and E1A. Output ype No. A-1, -, - D-1, -, -, - RE-*1 Mode A 1-A A See Page ON-Delay (signal start) Voltage is applied to the coil at all times. When a start input is supplied, the relay contacts remain in the off state and the set time begins. When the set time has elapsed, the relay contacts transfer to the on state. he contacts remain in the on state until the timer is reset. he timer is reset by applying a reset input or by removing the coil voltage. Applicable models: A-, D- and RE-P(B). Start Output ype No. A- D- RE-* Mode A -A A See Page ype No. E1A 5P 5Y See Page Interval 1 (power start) When voltage is applied to the coil, the relay contacts transfer immediately to the on state and the set time begins. When the set time has elapsed, the relay contacts transfer to the off state. he contacts remain in the off state until the timer is reset. he timer is reset by removing the coil voltage. Applicable models: RE-P(B)1, A-1, -, -, and D-1, -, -, -. Output ype No. A-1, -, - D-1, -, -, - RE-*1 Mode B 1-B B See Page Interval (signal start) Voltage is applied to the coil at all times. When a start signal is supplied, the relay contacts transfer immediately to the on state and the set time begins. When the set time has elapsed, the relay contacts transfer to the off state. he contacts remain in the off state until the timer is reset. he timer is reset by applying a reset input or by removing the coil voltage. Applicable models: A-5 and D-. Start Output ype No. A-5 D- Mode A -E See Page USA: (00) -IDEC or (0) , Canada () 17-IDEC

5 Cycle 1 (power start, OFF first) When voltage is applied to the coil, the contacts remain in the off state and the set time begins. At the end of the set time, the contacts transfer to the on state and remain in the on state until the set time elapses. he timer cycles between the two states until power is removed from the coil. Removing the coil voltage resets the timer. he set time for both the on state and the off state is the same. Applicable models: A-1, -, -, D-1, -, -, - and RE-P(B)1. iming Diagrams Overview Cycle (signal start, OFF first) Voltage is applied to the coil at all times. When a start signal is supplied, the relay contacts remain in the off state and the set time begins. At the end of the set time, the contacts transfer to the on state and remain in the on state until the set time elapses. he timer cycles between the two states until the timer is reset. he set time for both the on state and the off state are the same. he timer is reset by application of a reset input or by removing coil voltage. Applicable models: A-, D- and RE-P(B). Start Output Output ype No. A-1, -, - D-1, -, -, - RE-*1 Mode C 1-C C See Page Cycle (power start, ON first) When voltage is applied to the coil, the contacts immediately transfer to the on state and the set time begins. At the end of the set time, the contacts transfer to the off state and remain in the off state until the set time elapses. he timer cycles between the two states until power is removed from the coil. Removing the coil voltage resets the timer. he set time for both the off state and the on state is the same. Applicable models: A-1, -, -, D-1, -, -, - and RE-P(B)1. Output ype No. A-1, -, - D-1, -, -, - RE-*1 Mode D 1-D D See Page One Shot 1 (signal start, retriggerable) Voltage is applied to the coil at all times. When a start signal is supplied, the contacts immediately transfer to the on state and the set time begins. If another start signal is supplied (before set time has elapsed) the set time restarts, as the contacts remain in the on state. Successive pulses at a frequency greater than the set time will cause the contacts to remain in the ON state indefinitely. When the set time has elapsed the contacts transfer back to the off state. he contacts remain in the off state until the next start signal is supplied (no reset is necessary). he timer can be reset by application of a reset input or by removing coil voltage. Applicable models: A- and D-. ype No. A- D- RE-* Mode B -B B See Page One Shot Cycle (signal start) Voltage is applied to the coil at all times. When a start signal is supplied, the contacts remain in the off state and the set time begins. At the end of the set time, the contacts transfer to the on state and remain in the on state for the set time. After the set time has elapsed, the contacts return to the off state. he contacts remain in the off state until the timer is reset. he timer is reset by application of a reset input or by removing coil voltage. Applicable models: A-5 and D-. Start Output ype No. A-5 D- Mode B -F See Page One Shot (signal start) Voltage is applied to the coil at all times. When a start signal is supplied, the contacts immediately transfer to the on state and the set time begins. If another start signal is supplied (before set time has elapsed), the set time will not be affected. When the set time has elapsed, the contacts transfer back to the off state. he contacts remain in the off state until the next start signal is supplied (no reset is necessary). he timer can be reset by application of a reset input or by removing coil voltage. Applicable models: A-, D-, and RE-P(B). Start Start Output Output ype No. A- D- Mode A -C See Page ype No. A- D- RE-* Mode C -E F See Page = set time, = shorter than set time, s = one shot output time. For more detailed timing diagrams, see specifications for individual timer models. USA: (00) -IDEC or (0) , Canada () 17-IDEC -5

6 iming Diagrams Overview Signal ON/OFF-Delay 1 Voltage is supplied to the coil at all times. When a maintained start signal is supplied, the contacts immediately transfer to the on state and the set time begins. When the set time has elapsed, the contacts transfer to the off state. he contacts remain in the off state until the start signal is removed. he contacts transfer back to the on state and remain in the on state for the set time. When the set time has elapsed, the contacts transfer to the off state and remain in the off state until the start signal is supplied again (no reset is necessary). he timer is reset by application of a reset input or by removing coil voltage. Applicable models: A-, D- and RE-R(B). Start Signal ON/OFF-Delay Voltage is supplied to the coil at all times. When a maintained start signal is supplied, the contacts remain in the off state and the set time begins. When the set time has elapsed, the contacts transfer to the on state. he contacts remain in the on state until the start signal is removed. Once the start signal is removed, the contacts remain in the on state and the set time begins again. Once the set time has elapsed, the contacts transfer back to the off state. he timer is ready for the next start signal. he timer is reset by the application of a reset signal or removal of power. Applicable models: A-5 and D-. Start Output Output ype No. A- D- RE-* Mode C -C D See Page ype No. A-5 D- Mode C -A See Page Signal ON/OFF-Delay Voltage is supplied to the coil at all times. When a momentary start signal is supplied, the contacts remain in the off state and the set time begins. When the set time has elapsed, the contacts transfer to the on state. he contacts remain in the on state until another momentary input is supplied. he contacts then remain in the on state for the set time. When the set time has elapsed, the contacts transfer to the off state and remain in the off state until the start signal is supplied again (no reset is necessary). he timer is reset by application of a reset input or by removing coil voltage. Applicable models: A- and D-. Start Output ype No. A- D- Mode D -F See Page Signal OFF-Delay 1 Voltage is applied to the coil at all times. When a start signal is supplied, the contacts immediately transfer to the on state. he set time begins when the start signal is removed. When the set time has elapsed, the contacts transfer to the off state. he contacts remain in the off state until the next start signal is supplied (no reset is necessary). he timer can be reset by application of a reset input or by removing coil voltage. Applicable models: RE- P(B), A-, and D-. Start Output ype No. A- D- RE-* Mode D -D E See Page One Shot ON-Delay (signal start) When voltage is applied to the coil, the preset time is initiated and the contacts remain in the off state for the preset time. Following the preset time, the contacts transfer to the on state, and remain in the on state until the start input is supplied. Following the start input, the contacts transfer to the off state for the preset time. After the preset time has elapsed, the contacts transfer back to the on state and remain there until either the next start input is supplied or the timer is reset. he timer can be reset by either a reset input or removal of the coil voltage. Applicable models: A- and D-. Start Output ype No. A- D- Mode B -D See Page Signal OFF-Delay Voltage is applied to the coil at all times. When a maintained start signal is supplied, the contacts remain in the off state. When the start signal is removed, the contacts transfer to the ON state and the set time begins. When the set time has elapsed, the contacts transfer back to the off state. hey remain in the off state until the next start signal is supplied (no reset is necessary. he timer can be reset by application of a reset input or by removing coil voltage. Applicable models: A-5 and D-. Start Output ype No. A-5 D- Mode D -B See Page = set time, = shorter than set time, s = one shot output time. For more detailed timing diagrams, see specifications for individual timer models. - USA: (00) -IDEC or (0) , Canada () 17-IDEC

7 ON-Delay One-Shot Output 1 (signal start) Voltage is applied to the coil at all times. When a momentary start signal is supplied, the contacts remain in the off state and the preset time begins. Following the preset time, the contacts transfer to the on state and remain in the on state for the one-shot preset time. Following the one-shot preset time, the contacts transfer back to the off state and remain there until the timer is reset. he timer can be reset by applying either a reset input or removal of the coil voltage. Applicable model: D-. Start iming Diagrams Overview Cycle One-Shot Output (signal start) Voltage is applied to the coil at all times. When a momentary start signal is supplied, the contacts remain in the off state and the preset time begins. Following the preset time, the contacts transfer to the on state. he contacts remain in the on state for the one-shot preset time. After the one-shot preset time has elapsed, the contacts transfer back to the off state. he contacts remain in the off state for the preset time minus the one-shot preset time. he timer cycles between on and off states until the timer is reset by a reset input or removal of the coil voltage. Applicable model: D-. Start Output s Output s s s ype No. Mode 1 See Page - D- ype No. Mode See Page - D- ON-Delay One-Shot Output (signal start) Voltage is applied to the coil at all times. When a maintained start signal is supplied, the contacts remain in the off state and the preset time begins. Following the preset time (start input is still present), the contacts transfer to the on state and remain in the on state for the one-shot preset time. When the one-shot preset time has elapsed, contacts transfer back to the off state and remain there until timer is reset. he timer can be reset by a reset input, removal of the coil voltage or removal of start input. Applicable model: D-. Start Output ype No. Mode See Page - D- Sequential Start (power start) When voltage is applied to the coil, both contacts remain in the OFF state and the set time, 1, begins. When 1 has elapsed, output 1 comes on and begins. When has elapsed, output comes on. Both outputs remain on until power is removed from the coil. Applicable model: W-A. Output 1 s rue -OFF Delay When voltage is applied, output comes on immediately; when voltage is removed from the coil, the timer begins timing (internal capacitors power the timing circuit). When time has expired, contacts transfer back to the OFF state. If power is reapplied before the elapsed time has expired, the timing function will reset back to the starting point. Applicable models: F-1,. Output ype No. F-1, Mode OFF-Delay See Page - Recycler Outputs (power start) When voltage is applied to the coil, both contacts remain in the off state and time 1 begins. When 1 has elapsed, both contacts transfer to the ON state and begins. When has elapsed, both contacts transfer back to the OFF state and 1 begins again. he cycle continues until power is removed, at which time both contacts transfer back to the OFF state. Applicable model: W-A. Output Output ype No. Mode AA See Page - W-A ype No. Mode BB See Page - W-A 1. = set time, = shorter than set time, s = one shot output time. For more detailed timing diagrams, see specifications for individual timer models. USA: (00) -IDEC or (0) , Canada () 17-IDEC -7

8 RE Series RE Series Analog NEW DESIN! Key features of the RE series include: 0 time ranges and timing functions delays up to 00 hours Space-saving package High repeat accuracy of ± 0.% ON and timing OU LED indicators Standard - or 11-pin and 11-blade termination form C delayed output contacts A Rating Cert. No. E (EMC, RE) cert. No. BL90155 (LVD, RE) UL Listed File No. E0 eneral Specifications System Solid state CMOS Circuit ype Multi-Mode Range 0.1sec to 00hours Pollution Degree (IE0-1) Over voltage category III (IE0-1) AF0 0-0V AC(50/0Hz) Rated al AD V AC(50/0Hz)/V DC Voltage D1 1V DC AF0 5-V AC(50/0Hz) Voltage olerance AD 0.-.V AC(50/0Hz)/1.-.V DC D1.-1.V DC off Voltage Rated Voltage x% minimum Ambient Operating emperature -0 to +5ºC (without freezing) Ambient Storage and ransport emperature -0 to +75ºC (without freezing) Relative Humidity 5 to 5%RH (without condensation) Atmospheric Pressure 0kPa to 1kPa (Operating), 70kPa to 1kPa (ransport) Reset 0msec maximum Repeat Error ±0.%, ±0msec* Voltage Error ±0.%, ±0msec* emperature Error ±0.5%, ±0msec* Setting Error ±% maximum Insulation Resistance 0MΩ minimum (500V DC) Between power and output terminals: 000V AC, 1 minute Dielectric Strength Between contacts of different poles: 000V AC, 1 minute Between contacts of the same pole:00v AC, 1 minute Vibration Resistance to 55Hz amplitude 0.5mm hours in each of axes Operating extremes: 9m/sec () Shock Resistance Damage limits: 90m/sec (50) times in each of axes Degree of Protection IP0 (enclosure) (IEC059) YPE RE-P1, -B1 RE-P, -B Consumption (Approx.) AF0 V AC/0Hz.5VA.VA 0V AC/0Hz 11.VA 11.VA V AC 0Hz/DC.VA/1.7W.5VA/1.7W D1 1.W 1.W Free RE-P1, P 0Hx W x 77.9D mm RE-B1, B 0Hx W x 7.9D mm RE-P1 RE-P RE-B1, -B 7g 9g 5g Mounting Position Dimensions Weight (Approx.) *For the value of the error against a preset time, whichever the largest. Ratings Form C, DPD Configuration (Delay output) Allowable Voltage / 0V AC, 0V DC / A Allowable Current Maximum Permissible 100 cycles per hour Operating Frequency Rated Load Life Resistive Inductive Horse Rating Electrical Mechanical A 0V AC, 0V DC 7A 0V AC, 0V DC 1/ HP V AC, 1/ HP 0V AC 500,000 op. minimum (Resistive) 50,000,000 op. minimum RE able of Contents Specifications - Part Number uide -9 Part Number List -9 RE iming Diagrams - RE Accessories -11 Instructions: Setting r -1 RE Dimensions -1 eneral iming Diagrams USA: (00) -IDEC or (0) , Canada () 17-IDEC

9 RE Series Part Numbering uide RE series part numbers are composed of part number codes. When ordering a RE series part, select one code from each category. Example: RE-P1AF0 RE P 1 AF0 ➀ Series ➁ erminal Style ➂ Function roup ➃ Voltage Part Numbers: RE Series Description Part Number Code Remarks ➀ Series RE series RE For internal circuits, see next page. ➁ erminal Style ➂ Function roup ➃ Voltage Pin Blade ON-delay, interval, cycle OFF, cycle ON 1 ON-delay, cycle OFF, cycle ON, signal ON/OFF delay, OFF-delay, one-shot 0 to 0V AC(50/0Hz) AF0 V AC(50/0Hz)/V DC AD 1V DC D1 P B Select one only. Each function group has different timing functions. See page -. Part Number List Part Numbers New Part Number Voltage erminals Obsolete Part Number RE-B1AD V AC/DC Blade RE-B1AF0 0-0V AC Blade RE-B1D1 1V DC Blade RE-BAD V AC/DC Blade RE-BAF0 0-0V AC Blade RE-BD1 1V DC Blade RE-P1AD V AC/DC Pin RE-P1AF0 0-0V AC Pin RE-P1D1 1V DC Pin RE-PAD V AC/DC 11 Pin RE-PAF0 0-0V AC 11 Pin RE-PD1 1V DC 11 Pin RE-B11-V RE-B1-V RE-B11-ACV RE-B1-ACV RE-B11-1V RE-B1-1V RE-B1-V RE-B-V RE-B1-ACV RE-B-ACV RE-B1-1V RE-B-1V RE-P11-V RE-P1-V RE-P11-ACV RE-P1-ACV RE-P11-1V RE-P1-1V RE-P1-V RE-P-V RE-P1-ACV RE-P-ACV RE-P1-1V RE-P-1V 1. For schematics, see page -.. For timing diagrams, see page -.. All timers have multiple time ranges. For a list of ranges, see page -1.. For socket and accessory information, see page USA: (00) -IDEC or (0) , Canada () 17-IDEC -9

10 RE Series iming Diagrams (~/+) RE-P (~/-) external control (~/+) RE-P start (~/-) (~/+) RE-B1 1 7 A 5 9 B (~/-) external control (~/+) RE-B 1 A start 5 7 RE-P1, -B1 A: ON-Delay 1 (power start) B: Interval (power start) Set timer for desired delay, apply power to coil. s transfer after preset Set timer for desired delay, apply power to coil. s transfer immediately, and time has elapsed, and remain in transferred position until timer is reset. Reset return to original position after preset time has elapsed. Reset occurs with removal occurs with removal of power. of power. Item erminal No. (1)-7 ()A-B PWR OU (1)1-,5- ()1-7,-9 (1)1-,- ()-7,-9 9 B (~/-) Item erminal No. (1)-7 ()A-B PWR OU (1)1-,5- ()1-7,-9 (1)1-,- ()-7,-9 1. RE-P: Do not apply voltage to terminals #5, # & #7.. RE-B1, -B: Do not apply voltage to terminals #, #5 & #.. IDEC sockets are as follows: RE-P1: SRP-0* pin type socket, RE-P: SRP-05* pin type socket, RE-B1, -B: SRB-05* blade type socket, (*-may be followed by suffix letter A,B,C or U). C: Cycle 1 (power start, OFF first) Set timer for desired delay, apply power to coil. First transfer of contacts occurs after preset delay has elapsed, after the next elapse of preset delay contacts return to original position. he timer now cycles between on and off as long as power is applied (duty ratio 1:1). Item erminal No. (1)-7 ()A-B PWR OU (1)1-,5- ()1-7,-9 (1)1-,- ()-7,-9 A: ON-Delay (signal start) When a preset time has elapsed after the start input turned on while power is on, the NO output contact goes on. Item erminal No. (A)- (B)A-B (A)5- Start (B)-5 PWR OU (A)1-,-11 (B)1-7,-9 (A)1-,9-11 (B)-7,-9 D: Cycle (power start, ON first) Functions in same manner as Mode C, with the exception that first transfer of contacts occurs as soon as power is applied. he ratio is 1:1. On = Off Item erminal No. (1)-7 ()A-B PWR OU (1)1-,5- ()1-7,-9 (1)1-,- ()-7,-9 RE-P, -B B: Cycle (signal start, OFF first) When the start input turns on while power is on, the output oscillates at a preset cycle (duty ratio 1:1), starting while the NO contact off. Item erminal No. (A)- (B)A-B (A)5- Start (B)-5 PWR OU (A)1-,-11 (B)1-7,-9 (A)1-,9-11 (B)-7,-9 a C: Cycle (signal start, ON first) When the start input turns on while power is on, the NO contact goes on. he output oscillates at a preset cycle (duty ratio 1:1). Item erminal No. (A)- (B)A-B (A)5- Start (B)-5 PWR OU (A)1-,-11 (B)1-7,-9 (A)1-,9-11 (B)-7,-9 E: Signal OFF-Delay When power is turned on while the start input is on, the NO output contact goes on. When a preset time has elapsed after the start input turned off, the NO output contact goes off. Item erminal No. (A)- (B)A-B (A)5- Start (B)-5 PWR OU (A)1-,-11 (B)1-7,-9 (A)1-,9-11 (B)-7,-9 a a a F: One-Shot (signal start) When the start input turns on while power is on, the NO output contact goes on. When a preset time has elapsed, the NO output contact goes off. Item erminal No. (A)- (B)A-B (A)5- Start (B)-5 PWR OU (A)1-,-11 (B)1-7,-9 (A)1-,9-11 (B)-7,-9 D: Signal ON/OFF-Delay When the start input turns on while power is on, the NO output contact goes on. When a preset time has elapsed while the start input remains on, the output contact goes off. When the start input turns off, the NO contact goes on again. When a preset time has elapsed after the start input turned off, the NO contact goes off. Item erminal No. (A)- (B)A-B (A)5- Start (B)-5 PWR OU (A)1-,-11 (B)1-7,-9 (A)1-,9-11 (B)-7,-9 a a a a Note : =, a=shorter than set time, (1): RE-P1, (): RE-B1, (A): RE-P, (B): RE-B - USA: (00) -IDEC or (0) , Canada () 17-IDEC

11 RE Series DIN Rail Mounting Accessories Part Numbers: DIN Rail/Surface Mount Sockets and Hold-Down Springs DIN Rail Mount Socket Applicable Hold-Down Springs Style Appearance Use with Part No. Appearance Part No. 11-Pin Screw erminal (dual tier) RE-P SRP-05 SFA-0 11-Pin FingerSafe Socket RE-P SRP-05C -Pin Screw erminal RE-P1 SRP-0 SFA-0 11-Blade Screw erminal RE-B1 RE-B SRB-05 DIN Mounting Rail Length 00mm BNDN00 Installation of Hold-Down Springs DIN Rail Mount Socket Insert the springs into the outer slots with the projections facing inside. Insert the springs into the slots. Socket SRP-0 Hold Down Spring SFA-0 Socket SRP-05 Hold Down Spring SFA-0 Once installed into the sockets, the hold-down springs cannot be removed. USA: (00) -IDEC or (0) , Canada () 17-IDEC -11

12 RE Series Panel Mounting Accessories Part Numbers: Flush Panel Mount Adapter and Sockets that use an Adapter Accessory Description Appearance Use with Part No. Panel Mount Adapter Adaptor for flush panel mounting RE timers All RE timers RB-01 -pin screw terminal RE-P1 SRP-M0 Sockets for use with Panel Mount Adapter 11-pin screw terminal (Shown: SRP-M0 for Wiring Socket RE-P SRP-M11 Adapter) -pin solder terminal RE-P1 SRP-S0 11-pin solder terminal RE-P SRP-S11 No hold down clips are available for flush panel mounting applications USA: (00) -IDEC or (0) , Canada () 17-IDEC

13 RE Series emperature Derating Curves Mounting A Allowable Current A 7A Mounting B Allowable Current Mounting A Mounting B Derating Curve Derating Curve 50ºC 5ºC 50ºC 5ºC Ambient emperature Ambient emperature 7A 5A Instructions ypes RE-P1AF0 Connection type P: Pin B: Blade Mode 1: No Control Signal A: ON-Delay 1 B: Interval C: Cycle 1 D: Cycle Voltage AF0: 0 to 0V AC(50/0Hz) AD: V AC(50/0Hz)/V DC D1: 1V DC : Control Signal A: ON-Delay B: Cycle C: Cycle D: Signal ON/OFF-Delay E: Signal OFF-Delay F: One-Shot Special expertise is required to use Electronic. All Electronic are manufactured under IDEC's rigorous quality control system, but users must add a backup or fail safe provision to the control system when using the Electronic r in applications where heavy damage or personal injury may occur should the Electronic r fail. Install the Electronic r according to instructions described in this catalog. Make sure that the operating conditions are as described in the specifications. If you are uncertain about the specifications, contact IDEC in advance. In these directions, safety precautions are categorized in order of importance under Warning and Caution. Warnings Warning notices are used to emphasize that improper operation may cause severe personal injury or death. urn power off to the Electronic timer before starting installation, removal, wiring, maintenance, and inspection on the Electronic r. Failure to turn power off may cause electrical shocks or fire hazard. Do not use the Electronic r for an emergency stop circuit or interlocking circuit. If the Electronic r should fail, a machine malfunction, breakdown, or accident may occur. Safety Precautions Switch Settings 1 1 Mode Selector Scale Selector Range Selector 1. urn the selectors securely using a flat screwdriver mm wide (maximum). Note that incorrect setting may cause malfunction. Do not turn the selectors beyond their limits.. Since changing the setting during timer operation may cause malfunction, turn power off before changing. Caution Caution notices are used where inattention might cause personal injury or damage to equipment. he Electronic r is designed for installation in equipment. Do not install the Electronic r outside equipment. Install the Electronic r in environments described in the specifications. If the Electronic r is used in places where it will be subjected to high-temperature, high-humidity, condensation, corrosive gases, excessive vibrations, or excessive shocks, then electrical shocks, fire hazard, or malfunction could result. Use an IEC017-approved fuse and circuit breaker on the power and output line outside the Electronic r. Do not disassemble, repair, or modify the Electronic r. When disposing of the Electronic r, do so as industrial waste. USA: (00) -IDEC or (0) , Canada () 17-IDEC -1

14 RE Series Dimensions.0 RE-P1, -P RE-B1, -B (UNI: mm) SRP-0 Socket SRP-0 Socket 1.50" (0mm) 0.1" (mm) 0.995" (5.5mm) DIN Rail.01" (59mm) 0.1" (mm) 0.995" (5.5mm)." (0mm) Ø0.1" (Ø.) Mounting Hole 0.975" (5).0" (0mm) Ø0.1" (.mm) Mounting Hole Ø1.05" (Ø7) 0.09" M.5 (1mm) 1.7" erminal Screw (mm) SRB-05 Socket 1.0" (mm) 0.1" (mm) 0.70" (1mm) 0.5" (mm) 1.111" (.5mm) 1.7" (mm) BNDN00 DIN Rail 1.5" ±0.01 (5mm ±0.) M.5 erminal Screw 0.1" +0.00, -0 (.5mm +0.5, -0) 0.70" (1mm) 0.5" (mm).9" (7mm) 0.07" (mm) 1." (7mm) 1.77" (mm) Ø 0.1" (Ø.).1" (5mm) M.5 erminal Screw 0.5" (1.5mm) 0.975" (5mm) " (9mm) 1.99" (51mm) 1.99" (51mm) 9.7" (00mm) Ø 0.1" x 0." Slot, Places (Ø.mm x 1.5mm) -1 USA: (00) -IDEC or (0) , Canada () 17-IDEC

15 A Series A Series Analog Key features of the A series include: selectable operation modes on each model External start, reset, and pause inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEDs UL, c-ul Listed File No. E5599 Specifications A-1 A- A- A-,-5,- Multi-mode Multi-mode with inputs (11 pins) Range Rated Voltage Ratings Minimum Applicable Load Voltage olerance Error Setting Error Reset Insulation Resistance Dielectric Strength Consumption (approximate) 15V AC/50V AC, A; 0V DC, 1A (resistive load) SPD.VA (00V AC, 0Hz) 0.05s to 10 hours 0 to 0V AC, 50/0Hz 1V DC V AC, 50/0Hz / V DC 5V, ma (reference value) AF0 (0V AC): 5 to V AC AD: 0. to.v AC/1. to.v DC D1:. to 1.V DC 15V AC/50V AC, 5A; 0V DC, 5A (resistive load) ±0.%, ± msec (repeat, voltage, temperature) ±% maximum 0msec maximum 0MΩ minimum Between power and output terminals:,000v AC, 1 minute Between contacts of different poles:,000v AC, 1 minute Between contacts of the same pole: 750V AC, 1 minute SPD + instantaneous SPD 1.5VA (00V AC, 0Hz) DPD 1.VA (00V AC, 0Hz) DPD.7VA (0V AC, 0Hz), 1.VA (00V AC, 0Hz) 1VDC/1W 1VDC/1.1W 1VDC/0.W VDC/0.7W VAC/1.VA VDC/0.W VAC/1.VA VDC/0.W VAC/1.VA Mechanical Life,000,000 operations minimum 5,000,000 operations minimum Electrical LIfe 50,000 operations minimum (rated load) 0,000 operations minimum (rated load) Weight (approximate) g 7g 79g 0g Vibration Resistance 0m/sec (approximate ) Shock Resistance Operating emperature Operating Humidity Storage emperature Housing Color Operating extremes: 0m/sec (approximate ) Damage limits: 500m/sec (approximate 50) to +50 C 5 to 5% RH 0 to +0 C ray A able of Contents Specifications -15 Part Number List -1 iming Diagrams/Schematics -17 Instructions: Setting r - Accessories -50 Instructions: Wiring s -5 Dimensions -5 iming Diagrams Overview - USA: (00) -IDEC or (0) , Canada () 17-IDEC -15

16 A Series Part Number List Part Numbers: A-1, -, - Mode Of Rated Voltage Code Range Output Complete Part No. -Pin 11-Pin A: ON-delay 1 B: Interval 1 C: Cycle 1 D: Cycle AF0: 0 to 0V AC (50/0Hz) AF0: 0 to 0V AC (50/0Hz) D1: 1V DC AD: V AC (50/0Hz)/V DC 0.05s. to 10 hours 50V AC, A, 0V DC, 1A (resistive load) 0V AC, 5A, V DC, 5A (resistive load) SPD A-1AF0 A-1EAF0 SPD + Instantaneous SPD DPD A-AF0 A-D1 A-AD A-AF0 A-D1 A-AD A-EAF0 A-ED1 A-EAD A-EAF0 A-ED1 A-EAD 1. For wiring schematics and timing diagrams for A-1, -, -, see pages -17, -1, or -19 respectively.. For more details about time ranges, see instructions on page -.. For socket and accessory part numbers, see page -50. Part Numbers: A-, -5, - Mode of Rated Voltage Code Range Output Complete Part No. A (11-pin) B (11-pin) A: ON-Delay B: Cycle C: Signal ON/OFF-Delay 1 D: Signal OFF-Delay 1 AF0: 0 to 0V AC (50/0Hz) D1: 1V DC AD: V AC (50/0Hz)/V DC A: Interval B: One-Shot Cycle C: Signal ON/OFF-Delay D: Signal OFF-Delay AF0: 0 to 0V AC (50/0Hz) A: One-Shot AD: V AC (50/0Hz)/V DC B: One-Shot ON-Delay C: One-Shot D: Signal ON/OFF-Delay 0.05 seconds to 10 hours 50V AC, 5A, V DC, 5A (resistive load) DPD Start Reset ate A-AF0 A-D1 A-AD A-5AF0 A-5AD A-AF0 A-AD A-EAF0 A-ED1 A-EAD A-5EAF0 A-5EAD A-EAF0 A-EAD. For wiring schematics and timing diagrams A-,-5,-, see pages -0, -1, and - respectively. 5. For more details about time ranges, see instructions on page -.. A (11-pin) and B (11-pin) differ in the way inputs are wired. 7. For socket and accessory part numbers, see page For the timing diagrams overview, see page USA: (00) -IDEC or (0) , Canada () 17-IDEC

17 A Series iming Diagrams/Schematics A- 1 iming Diagrams SPD Mode Selection -Pin (-) (+) 11-Pin (-) (+) ON-Delay 1 MODE A Item erminal No. -7 (p) () - (11p) 5- (p) -11 (11p) - (p) 9-11 (11p) OU Interval 1 MODE B Item erminal No. -7 (p) () - (11p) 5- (p) -11 (11p) - (p) 9-11 (11p) OU Cycle 1 (OFF first) MODE C Item erminal No. -7 (p) () - (11p) 5- (p) -11 (11p) - (p) 9-11 (11p) OU Cycle (ON first) MODE D Item erminal No. -7 (p) () - (11p) 5- (p) -11 (11p) - (p) 9-11 (11p) OU USA: (00) -IDEC or (0) , Canada () 17-IDEC -17

18 A Series A- iming Diagrams SPD + Instantaneous SPD -Pin 5 11-Pin 7 (-) Mode Selection 1 (+) (-) (+) ON-Delay 1 MODE A Item erminal No. -7 (p) () - (11p) 5- (p) -11 (11p) - (p) 9-11 (11p) Instantaneous 1-1- OU Interval 1 MODE B Item erminal No. -7 (p) () - (11p) 5- (p) -11 (11p) - (p) 9-11 (11p) Instantaneous 1-1- OU Cycle 1 (OFF first) MODE C Item erminal No. -7 (p) () - (11p) 5- (p) -11 (11p) - (p) 9-11 (11p) Instantaneous 1-1- OU Cycle (ON first) MODE D Item erminal No. -7 (p) () - (11p) 5- (p) -11 (11p) - (p) 9-11 (11p) Instantaneous 1-1- OU -1 USA: (00) -IDEC or (0) , Canada () 17-IDEC

19 A Series A- iming Diagrams DPD -Pin 5 11-Pin 7 (-) Mode Selection 1 (+) (-) (+) ON-Delay 1 MODE A Item erminal No. -7 (p) () - (11p) 1-, 5- (p) 1-, -11(11p) 1-, - (p) 1-, 9-11(11p) OU Interval 1 MODE B Item erminal No. -7 (p) () - (11p) 1-, 5- (p) 1-, -11(11p) 1-, - (p) 1-, 9-11(11p) OU Cycle 1 (OFF first) MODE C Item erminal No. -7 (p) () - (11p) 1-, 5- (p) 1-, -11(11p) 1-, - (p) 1-, 9-11(11p) OU Cycle (ON first) MODE D Item erminal No. -7 (p) () - (11p) 1-, 5- (p) 1-, -11(11p) 1-, - (p) 1-, 9-11(11p) OU USA: (00) -IDEC or (0) , Canada () 17-IDEC -19

20 A Series A- iming Diagrams Mode Selection ON-Delay Cycle MODE A MODE B Signal ON/OFF-Delay 1 MODE C Signal OFF-Delay 1 MODE D DPD (A ype) ( ) (ransistor ) (B ype) 5 7 ResetStartate 9 (-) 1 11 (+) Reset Startate (-) 1 11 (+) Start Reset (-) Note: = Set time a = Shorter than set time = ' + " (+) Item erminal No. Start Reset ate - () - (A) 5-7 (B) ON or L -7 (A) -7 (B) ON or L -5 (A) ON or L OU a ' " Note: While the gate input is on during time-delay operation, the indicator flash rate slows down. Item erminal No. - () Start - (A) 5-7 (B) ON or L Reset -7 (A) -7 (B) ON or L ate -5 (A) ON or L OU a Item erminal No. - () Start - (A) 5-7 (B) ON or L Reset -7 (A) -7 (B) ON or L ate -5 (A) ON or L OU a a a Item erminal No. - () Start - (A) 5-7 (B) ON or L Reset -7 (A) -7 (B) ON or L ate -5 (A) ON or L OU a a a -0 USA: (00) -IDEC or (0) , Canada () 17-IDEC

21 A Series A- 5 iming Diagrams. Mode Selection DPD (A ype) ( ) (ransistor ) (B ype) 5 7 Reset Startate ResetStartate 9 (-) 1 11 (+) (-) 1 11 (+) Start Reset (-) Note: = Set time 5 a = Shorter 7 than set time = (+) Interval MODE A One-Shot Cycle MODE B Signal ON/OFF-Delay MODE C Signal OFF-Delay MODE D Item erminal No. Start Reset ate - () - (A) 5-7 (B) ON or L -7 (A) -7 (B) ON or L -5 (A) ON or L OU a ' " Item erminal No. Start Reset ate - () - (A) 5-7 (B) ON or L -7 (A) -7 (B) ON or L -5 (A) ON or L OU a ' " Item erminal No. Start Reset ate - () - (A) 5-7 (B) ON or L -7 (A) -7 (B) ON or L -5 (A) ON or L OU a a a ' " a Item erminal No. Start Reset ate - () - (A) 5-7 (B) ON or L -7 (A) -7 (B) ON or L -5 (A) ON or L OU a a ' " USA: (00) -IDEC or (0) , Canada () 17-IDEC -1

22 A Series A- iming Diagrams Mode Selection One-Shot 1 MODE A One-Shot ON-Delay MODE B One Shot MODE C Signal ON/OFF-Delay MODE D DPD (A ype) ( ) (ransistor ) (B ype) 5 7 Reset Startate ResetStartate 9 (-) 1 11 (+) Start Reset (-) 1 11 (+) (-) Item erminal No. Start Reset ate - () - (A) 5-7 (B) ON or L -7 (A) -7 (B) ON or L -5 (A) ON or L OU a a a ' " Item erminal No. Start Reset ate - () - (A) 5-7 (B) ON or L -7 (A) -7 (B) ON or L -5 (A) ON or L OU a ' " Item erminal No. Start Reset ate - () - (A) 5-7 (B) ON or L -7 (A) -7 (B) ON or L -5 (A) ON or L OU a ' " Note: = Set time 5 a = Shorter 7 than set time = ' + " (+) Item erminal No. Start Reset ate - () - (A) 5-7 (B) ON or L -7 (A) -7 (B) ON or L -5 (A) ON or L OU a ' " a a - USA: (00) -IDEC or (0) , Canada () 17-IDEC

23 A Series Instructions: Setting A Series d OU (flashes during time-delay period) ➃ Setting Knob ➀ Mode Selector A, B, C, D ➂ Range Selector 1S, S, M, H A ➁ Dial Selector 0-1, 0-, 0-, 0-1 Step 1. Desired Mode of Selection Remarks For Mode of ➀ Mode Selector Select the desired mode of operation. A-1 A- A- A- A-5 ON-delay 1 Interval 1 Cycle 1 Cycle ON-delay Cycle Signal ON/OFF-delay 1 Signal OFF-delay 1 Interval One-shot cycle Signal ON/OFF-delay Signal OFF-delay A B C D A B C D A B C D he desired operation mode can be selected from the A, B, C, and D modes using the Mode Selector. Change the operation mode from A to B, C, and D in turn by turning the operation mode selector clockwise using a flat screwdriver which is a maximum of 0.15 (mm) wide. he selected mode is displayed in the window. One-shot 1 A One-shot ON-delay B A- One-shot C Signal ON/OFF-delay D Step. Desired Range Selection Remarks Ranges ➁ Dial Selector ➂ Range Selector Select the time range that contains the desired time period. Step seconds to 1 second seconds to seconds seconds to seconds seconds to 1 seconds seconds to seconds seconds to 0 seconds 0-0. seconds to 0 seconds 0-1. seconds to 10 seconds 0-1 seconds to minutes seconds to 0 minutes 0- seconds to 0 minutes 0- seconds to 10 minutes 0-1 minutes to hours minutes to 0 hours 0- minutes to 0 hours 0- minutes to 10 hours 0-1 Selection 1S S M H he desired time range is selected by setting both ➁ Dial Selector and ➂ Range Selector. Set the precise period of time desired by using the ➃ Setting Knob. USA: (00) -IDEC or (0) , Canada () 17-IDEC -

24 D Series D Series Digital Key features of the D series include: Precise time setting using digital thumbwheel switches Elapsed or time remaining LED display time ranges, 1 timing functions delays up to 99.9 hours UL Recognized File No.E5599 CSA Certified File No.LR51 LR97 LR1 Cert. No. BL (LVD) E (EMC) D-1 D- D- D- D- System Solid state CMOS circuitry Multi-mode Multi-mode. one-shot output Range Rated Voltage 0.01s to 99.9 hours 0 to 0V AC (50/0Hz), V AC (50/0Hz)/V DC Ratings 15V AC/50V AC, A; 0V DC/1A (resistive load) 15V AC/50V AC, 5A; 0V DC/5A (resistive load) Form Minimum Applicable Load SPD SPD + instantaneous SPD DPD 5V, ma (reference value) DPD DPD Specifications Voltage olerance Error Setting Error Reset Insulation Resistance Dielectric Strength Consumption (approximate) AF0 (0 0V AC): 5 to V AC AD (AC): 0. to.v AC AD (DC): 1. to.v DC ±0.% ±50ms (voltage, repeat, and temperature) ±0.5% ±50ms 0ms maximum 0MΩ minimum Between power and output terminals:,000v AC, 1 minute Between contacts of different poles:,000v AC, 1 minute Between contacts of the same pole: 750V AC, 1 minute AF0.VA 11.VA 11.VA.7VA (0V AC, 0Hz) 11.VA (00V AC, 0Hz) AD AC/DC 0.9VA/0.W 1VA/0.W.1VA/0.9W.1VA /0.9W Mechanical Life,000,000 operations minimum 5,000,000 operations minimum Electrical Life (at rated load) 50,000 operations minimum 0,000 operations minimum Outputs Relay 50V AC, A, 0V DC, 1A (resistive load) Vibration Resistance 0N (approximate ) 0V AC/, V DC, 5A (resistive load) Shock Resistance Operating extremes: 0N (approximate ) Damage limits: 500N (approximate 50) Operating emperature to +50 C Storage emperature 0 to +0 C Operating Humidity 5 to 5% RH Weight (approximate) 0g 70g 75g 7g Housing Color ray D able of Contents Specifications - Part Number List -5 iming Diagrams/ Schematics - Instructions: Setting r -5 Accessories -50 Instructions: Wiring s -5 Dimensions -5 iming Diagrams Overview USA: (00) -IDEC or (0) , Canada () 17-IDEC

25 D Series Part Number List Part Numbers: D-1/D-/D- Mode of 1-A: ON-delay 1 1-B: Interval 1 first 1-C: Cycle 1 (OFF first) 1-D: Cycle (ON first) Range 0.01s to 99.9 hours Output Rated Voltage Code 50V AC, A, 0V DC, 1A (resistive load) 0V AC/, V DC, 5A (resistive load) SPD SPD + instantaneous SPD DPD Complete Part No. -Pin 11-Pin 0 to 0V AC (50/0Hz) D-1AF0 D-1EAF0 V AC/DC D-1AD 0 to 0V AC (50/0Hz) D-AF0 D-EAF0 V AC/DC D-AD 0 to 0V AC (50/0Hz) D-AF0 D-EAF0 V AC/DC D-AD Part Numbers: D- Mode of 1-A: ON-delay 1 1-B: Interval 1 first 1-C: Cycle 1 (OFF first) 1-D: Cycle (ON first) -A: ON-delay -B: Cycle -C: Signal ON/OFF-delay 1 -D: Signal OFF-delay 1 -E: Interval -F: One-shot cycle -A: Signal ON/OFF-delay -B: Signal OFF-delay -C: One-shot 1 -D: One-shot ON-delay -E: One-shot -F: Signal ON/OFF-delay Part Numbers: D- Mode of 1: ON-delay one-shot 1 : Cycle one-shot : ON-delay one-shot Range 0.01s to 99.9 hours Range 0.01s to 99.9 hours Output Rated Voltage Code 0V AC/V DC, 5A (resistive load) DPD 0 to 0V AC (50/0Hz) Complete Part No. A (11-pin) B (11-pin) D-AF0 D-EAF0 V AC/DC D-AD Output Rated Voltage Code Complete Part No. (11-pin) 0V AC/V DC, 5A (resistive load) DPD 0 to 0V AC (50/0Hz) D-AF0 V AC/DC D-AD 1. For wiring schematics and timing diagrams D, see pages - to -.. For more details about time ranges, see instructions on page -5.. A (11-pin) and B (11-pin) differ in the way inputs are wired.. For socket and accessory part numbers, see page For timing diagrams overview, see page -. USA: (00) -IDEC or (0) , Canada () 17-IDEC -5

26 D Series iming Diagrams/Schematics D-1 iming Diagrams SPD -Pin (-) (+) 11-Pin (-) (+) ON-Delay 1 Remaining 1 A Elapsed 1 A Interval 1 Remaining 1 B Elapsed 1 B Item erminal No. -7 (p) () - (11p) 5- (p) -11 (11p) - (p) 9-11 (11p) OU Digital DOWN Display UP Item erminal No. -7 (p) () - (11p) 5- (p) -11 (11p) 1- - (p) 9-11 (11p) 1- OU Digital DOWN Display UP Cycle 1 (OFF first) Remaining 1 C Elapsed 1 C Item erminal No. -7 (p) () - (11p) 5- (p) -11 (11p) 1- - (p) 9-11 (11p) 1- OU Digital DOWN Display UP Cycle (ON first) Remaining 1 D Elapsed 1 D Item erminal No. -7 (p) () - (11p) 5- (p) -11 (11p) - (p) 9-11 (11p) OU Digital DOWN Display UP - USA: (00) -IDEC or (0) , Canada () 17-IDEC

27 D Series D- iming Diagrams ON-Delay 1 Remaining 1 A Elapsed 1 A SPD + Instantaneous SPD -Pin 5 11-Pin (-) 7 (+) (-) Item erminal No. () -7 (p) - (11p) 1-, 5- (p) 1-, -11 (11p) 1-, - (p) 1-, 9-11 (11p) Instantaneous Digital Display 1-1- OU DOWN UP (+) Interval 1 Remaining 1 B Elapsed 1 B Item erminal No. () -7 (p) - (11p) 1-, 5- (p) 1-, -11 (11p) 1-, - (p) 1-, 9-11 (11p) Instantaneous 1-1- OU Digital Display DOWN UP Cycle 1 (OFF first) Remaining 1 C Elapsed 1 C Cycle (ON first) Remaining 1 D Elapsed 1 D Item erminal No. () -7 (p) - (11p) 1-, 5- (p) 1-, -11 (11p) 1-, - (p) 1-, 9-11 (11p) Instantaneous Digital Display 1-1- OU DOWN UP Item erminal No. () -7 (p) - (11p) 1-, 5- (p) 1-, -11 (11p) 1-, - (p) 1-, 9-11 (11p) Instantaneous 1-1- Digital Display OU DOWN UP USA: (00) -IDEC or (0) , Canada () 17-IDEC -7

28 D Series D- iming Diagrams Mode Selection DPD -Pin 5 11-Pin (-) 7 1 (+) (-) (+) ON-Delay 1 Remaining 1 A Elapsed 1 A Item erminal No. -7 (p) () - (11p) 1-, 5- (p) 1-, -11 (11p) 1-, - (p) 1-, 9-11 (11p) OU Digital DOWN Display UP Interval 1 Remaining 1 B Elapsed 1 B Item erminal No. -7 (p) () - (11p) 1-, 5- (p) 1-, -11 (11p) 1-, - (p) 1-, 9-11 (11p) OU Digital DOWN Display UP Cycle 1 (OFF first) Remaining 1 C Elapsed 1 C Item erminal No. -7 (p) () - (11p) 1-, 5- (p) 1-, -11 (11p) 1-, - (p) 1-, 9-11 (11p) OU Digital DOWN Display UP Cycle (ON first) Remaining 1 D Elapsed 1 D Item erminal No. -7 (p) () - (11p) 1-, 5- (p) 1-, -11 (11p) 1-, - (p) 1-, 9-11 (11p) OU Digital DOWN Display UP - USA: (00) -IDEC or (0) , Canada () 17-IDEC

29 D Series D- iming Diagrams hese timers require a start input. A gate and reset input are optional. s are controlled by external pushbuttons. Reset occurs when the power is removed or when the reset input is supplied. he gate signal can be used to interrupt (freeze) timer functions. r functions resume when the gate input is removed. B style timers are not equipped for gate input. D- DPD (A ype) ( ) (ransistor ) 5 7 Reset Startate ResetStartate 9 (-) 1 11 (+) (B ype) ( ) Start Reset (-) (+) (ransistor ) Start Reset (-) (-) 1 11 (+) (+) ON-Delay 1 Remaining 1 A Elapsed 1 A Item erminal No. D- - () OU Digital DOWN Display UP Interval 1 Remaining 1 B Elapsed 1 B Item erminal No. D- - () OU Digital DOWN Display UP USA: (00) -IDEC or (0) , Canada () 17-IDEC -9

30 D Series D- iming Diagrams, continued Cycle 1 (OFF first) Remaining 1 C Elapsed 1 C Item erminal No. D- - () OU Digital DOWN Display UP Cycle (ON first) Remaining 1 D Elapsed 1 D Item erminal No. D- - () OU Digital DOWN Display UP ON-Delay Item erminal No. D- - () Start ON or L - (A) 5-7 (B) - Reset ON or L -7 (A) -7 (B) -7 Remaining A Elapsed A ate ON or L -5 (A) OU Digital Display DOWN UP a -0 USA: (00) -IDEC or (0) , Canada () 17-IDEC

31 D Series D- iming Diagrams, continued Cycle Remaining B Elapsed B Signal ON/OFF-Delay 1 Remaining C Elapsed C Signal OFF-Delay 1 Remaining D Elapsed D Interval Remaining E Elapsed E Item erminal No. D- - () Start ON or L - (A) 5-7 (B) - Reset ON or L -7 (A) -7 (B) -7 ate ON or L -5 (A) -5 OU Digital DOWN Display UP Item erminal No. D- - () Start ON or L - (A) 5-7 (B) - Reset ON or L -7 (A) -7 (B) -7 ate ON or L -5 (A) -5 OU Digital DOWN Display UP Item erminal No. D- - () Start ON or L - (A) 5-7 (B) - Reset ON or L -7 (A) -7 (B) -7 ate ON or L -5 (A) -5 OU Digital DOWN Display UP Item erminal No. D- - () Start ON or L - (A) 5-7 (B) - Reset ON or L -7 (A) -7 (B) -7 ate ON or L -5 (A) -5 OU Digital DOWN Display UP a a a a a a a a USA: (00) -IDEC or (0) , Canada () 17-IDEC -1

32 D Series D- iming Diagrams, continued One-Shot Cycle Remaining F Elapsed F Signal ON/OFF-Delay Remaining A Elapsed A Signal OFF-Delay Remaining B Elapsed B One-Shot 1 Remaining C Elapsed C Item erminal No. D- - () Start ON or L - (A) 5-7 (B) - Reset ON or L -7 (A) -7 (B) -7 ate ON or L -5 (A) -5 OU Digital DOWN Display UP Item erminal No. D- - () Start ON or L - (A) 5-7 (B) - Reset ON or L -7 (A) -7 (B) -7 ate ON or L -5 (A) -5 OU Digital DOWN Display UP Item erminal No. D- - () Start ON or L - (A) 5-7 (B) - Reset ON or L -7 (A) -7 (B) -7 ate ON or L -5 (A) -5 OU Digital DOWN Display UP Item erminal No. D- - () Start ON or L - (A) 5-7 (B) - Reset ON or L -7 (A) -7 (B) -7 ate ON or L -5 (A) -5 OU Digital DOWN Display UP a a a a a a a - USA: (00) -IDEC or (0) , Canada () 17-IDEC a a

33 D Series D- iming Diagrams, continued One-Shot ON-Delay Remaining D Elapsed D Item erminal No. D- - () Start ON or L - (A) 5-7 (B) - Reset ON or L -7 (A) -7 (B) -7 ate ON or L -5 (A) -5 OU Digital Display DOWN UP a One Shot Remaining E Elapsed E Signal ON/OFF-Delay Item erminal No. D- - () Start ON or L - (A) 5-7 (B) - Reset ON or L -7 (A) -7 (B) -7 ate ON or L -5 (A) -5 OU Digital DOWN Display UP Item erminal No. D- - () Start ON or L - (A) 5-7 (B) - Reset ON or L -7 (A) -7 (B) -7 a Remaining F Elapsed F ate ON or L -5 (A) -5 OU Digital Display DOWN UP a a a a USA: (00) -IDEC or (0) , Canada () 17-IDEC -

34 D Series D- iming Diagrams DPD ( ) (ransistor ) 5 7 ResetStartate 9 (-) 1 11 (+) Reset Startate (-) 1 11 (+) Note: = Set time a = Shorter than set time b = Shorter than single-shot output time = + 0 = Single-shot output time (selected from A, B, C, D, E or F) Item erminal No. - () Start ON or L - ON-Delay One-Shot 1 Remaining 1 Elapsed 1 Reset ON or L -7 ate ON or L OU Digital DOWN Display UP Item erminal No. o a b o b - () Start ON or L - Cycle One-Shot Remaining Elapsed Reset ON or L -7 ate ON or L OU Digital Display DOWN UP a b a o o o o o Item erminal No. ON-Delay One-Shot Remaining Elapsed - () Start ON or L - Reset ON or L -7 ate ON or L OU Digital DOWN Display UP o a b a b b - USA: (00) -IDEC or (0) , Canada () 17-IDEC

35 D Series Instructions: Setting D-1, D-, D- d OU Digital Display (LCD backlit with red LED) ➃ Setting Digital Switch Select the desired time display and operation modes. Step 1 Desired Mode/Selection Remarks Select a time range that contains the desired period of time. Display Mode elapsed remaining elapsed remaining elapsed remaining elapsed remaining ➀ Indication Mode Selector 1 1 ➀ Mode Selector Base Ranges Mode ON-delay 1 Interval Cycle 1 Cycle ➁ Mode Selector A B C D 1. Use the flat screwdriver to set the selectors. Since selectors do not turn all the way around, both clockwise and counterclockwise rotation may be necessary.. he ➀ Mode Selector determines whether the Digital Display shows the time elapsed or time remaining. he ➁ Mode Selector determines the desired operation mode. Decide which display and mode is desired, then use these two selectors➀➁ to set the operation mode.. he ➁ Mode Selector has two blank modes which are not intended for use. Always have this selector set to A, B, C, or D. Step Desired Selection Remarks ➂ Range Selector 0.01 seconds to 9.99 seconds seconds to 99.9 seconds second to 999 seconds minutes to 99.9 minutes minute to 999 minutes hours to 99.9 hours 99.9 Decimal Point Increment 1. he ➂ Range Selector controls both the decimal point indicator (9.99, 99.9, 999) and the time increment indicators S (seconds), M (minutes), and H (hours).. Chose which base time range contains the targeted timer setting. hen use the ➂ Range Selector to set the decimal point indicator and time increment indicator to its corresponding pair of settings.. Since these configurations offer a complete range of settings from 0.01 seconds to 99.9 hours, the setting of 9.99 for minutes and the 9.99 and 999 settings for hours are not listed and should not be used. Step Desired Selection Remarks Set the precise period of time desired by using the ➃ Setting Digital Switch ➁ Mode Selector A, B, C, D S M H A B C D ➂ Range Selector 9.99S 99.9H Use the ➃ Setting Digital Switch to set the desired period of time. It is important to remember that the setting of the ➂ Range Selector determines the units of time measurement as well as the implied decimal point location. It is important to remember that the ➂ Range Selector not only selects the time range but also influences the interpretation of the Digital Display. Changing the ➂ Range Selector setting changes the units of time measurement (seconds, minutes, hours) as well as the decimal point location. USA: (00) -IDEC or (0) , Canada () 17-IDEC -5

36 D Series Instructions: Setting D- d OU Digital Display (LCD backlit with Red LED) ➀ Mode Selector/Indication Mode Selector ➃ Setting Digital Switch ➂ Range Selector 9.99S 99.9H ➁ Mode Selector A, B, C, D, E, F Step 1 Desired Mode/Selection Remarks Select the desired time display and operation modes. Select a time range that contains the desired period of time. Display Mode elapsed remaining elapsed remaining elapsed remaining ➀ Mode Selector Base Ranges ON-delay 1 Interval 1 Cycle 1 D: Cycle Mode ON-delay Cycle Signal ON/OFF-delay Signal OFF-delay 1 Interval One-shot cycle Signal ON/OFF-delay Signal OFF-delay One-shot 1 One-shot ON-delay One-shot Signal ON/OFF-delay A B C D A B C D E F A B C D E F ➁ Mode Selector 1. Use a flat screwdriver to set the selectors. Since selectors do not turn all the way around, both clockwise and counterclockwise rotation is necessary.. he ➀ Mode Selector determines whether the Digital Display shows the time elapsed or time remaining. he ➁ Mode Selector determines the desired operation mode. Decide which display and mode is desired; then use these two selectors➀➁ to set the operation mode.. When using the indicator mode setting 1, the ➁ Mode Selector has two blank modes which are not intended for use. When using mode setting 1, always have the operation mode selector set to A, B, C, or D. Step Desired Selection Remarks ➂ Range Selector 0.01 seconds to 9.99 seconds seconds to 99.9 seconds seconds to 999 seconds minutes to 99.9 minutes minute to 999 minutes hours to 99.9 hours 99.9 Decimal Point Increment 1. he ➂ Range Selector controls both the decimal point indicator (9.99, 99.9, 999) and the time increment indicator: S (seconds), M (minutes), and H (hours).. Choose the base time range which contains the targeted timer setting. hen use the ➂ Range Selector to set the decimal point indicator and time increment indicator to its corresponding pair of settings.. Since these configurations offer a complete range of settings from 0.01 seconds to 99.9 hours, the setting of 9.99 for minutes and the 9.99 and 999 settings for hours are not listed and should not be used. Step Desired Selection Remarks Select the desired period of time by using the ➃ Setting Digital Switch. 1 1 S M H Use the ➃ Setting Digital Switch to set the desired period of time. It is important to remember that the setting of the ➂ Range Selector determines the units of time measurement as well as the implied decimal point location. It is important to remember that the ➂ Range Selector not only selects the time range, but also influences the interpretation of the Digital Display. Changing the ➂ Range Selector setting changes the units of time measurement (seconds, minutes, hours) as well as the implied decimal point location. - USA: (00) -IDEC or (0) , Canada () 17-IDEC

37 D Series Instructions: Setting D- d OU Digital Display (LCD backlit with Red LED) ➃ Setting Digital Switch 1 1 ➁ Single-Shot Output Selector A, B, C, D, E, F Step 1 Desired Mode of Selection Remarks Mode Display Mode ➀ Mode Selector Select the time display and operation modes. ON-Delay One-Shot Cycle one-shot ON-delay one-shot elapsed remaining elapsed remaining elapsed remaining 1. Use a flat screwdriver to set the selectors. Since selectors do not turn all the way around, both clockwise and counterclockwise rotation is necessary.. he D- ➀ Mode Selector selects both whether the Digital Display displays the time elapsed or time remaining and also the mode of operation. Decide which display and mode is desired. hen use this selector to set the operation mode. Step Desired Mode of Selection Remarks Desired Single-Shot Output ➁ Single-Shot Output Selector Select the single shot output time. 0.1 seconds A 0.5 seconds B 1 second C 5 seconds D seconds E On the D- timers, the desired single-shot output time can be selected from the A, B, C, D, E, and F modes using the ➁ One-Shot Output Selector. 50 seconds F Step Desired Mode of Selection Remarks ➂ Range Selector Select the time range that contains the desired period of time. ➀ Indication Mode Selector Base Ranges 0.01 seconds to 9.99 seconds seconds to 99.9 seconds second to 999 seconds minutes to 99.9 minutes minute to 999 minutes hours to 99.9 hours 99.9 Decimal Point Increment 1. he ➂ Range Selector controls both the decimal point indicator (9.99, 99.9, 999) and the time increment indicator: S (seconds), M (minutes), and H (hours).. Chose which base time range contains the targeted timer setting. hen use the ➂ Range Selector to set the decimal point indicator and time increment indicator to its corresponding pair of settings.. Since these configurations offer a complete range of settings from 0.01s to 99.9 hours, the setting of 9.99 for minutes and the 9.99 and 999 settings for hours are not listed and should not be used. Step Desired Mode of Selection Remarks Select the desired period of time by using the ➃ Setting Digital Switch. ➂ Range Selector 9.99S 99.9H It is important to remember that the ➂ Range Selector not only selects the time range, but also influences the interpretation of the Digital Display. Changing the ➂ Range Selector setting changes the units of time measurement (seconds, minutes, hours) as well as the decimal point location. 1 1 Use the ➃ Setting Digital Switch to set the desired period of time. It is important to remember that the setting of the ➂ Range Selector selects the units of time measurement as well as the implied decimal point location. USA: (00) -IDEC or (0) , Canada () 17-IDEC -7 S M H

38 F Series F Series rue OFF Delay Key features of the F series include: Mountable in sockets or flush panel rue power OFF-delay up to minutes No external control switch necessary Available with reset inputs UL, c-ul Listed File No. E5599 Specifications F-1 rue power OFF-delay Range 0.05 seconds to 00 seconds Rated Voltage Rating 0 to 0V AC, 50/0Hz V AC/DC 50V AC/0V DC, 5A (resistive load) Form SPD DPD Minimum Application 1 second Voltage olerance Repeat Error Voltage Error emperature Error Setting Error Insulation Resistance Dielectric Strength Consumption Mechanical Life Electrical Life F- 50V AC/0V DC, A (resistive load) AF0: 0 to 0V AC AD: 1. to.vdc, 0. to.vac ±0.%, ± msec ±0.%, ± msec ±0.%, ± msec ±% maximum 0MΩ minimum Between power and output terminals:,000v AC, 1 minute (SPD) 1,500V AC, 1 minute (DPD) Between contacts on different poles: 1,000V AC, 1 minute (DPD) Between contacts of the same pole: 750V AC, 1 minute AF0:.7VA (00V AC, 0Hz) AD: 0.W (DC), 1.VA (AC) 0,000,000 operations minimum 0,000 operations minimum Vibration Resistance 0m/sec (approximate ) Operating extremes: Shock Resistance 0 m/sec (approximate ) Damage limits: 500 m/sec (approximate 50) Operating emperature to +50 C Storage emperature 0 to +0 C Operating Humidity 5 to 5% RH Weight (approximate) 77g 79g 1.An inrush current flows during the minimum power application time. AF0: approximate 0.A, AD: approximate 0.A.F does not read the preset values of each selector after power is turned off. Note that minimizing the preset time does not shorten the delay time after power is removed. F able of Contents Specifications - Part Number List -9 iming Diagrams/Schematics -9 Instructions: Setting r -1 Instructions: Wiring s - Accessories -50 Instructions -5 Dimensions -5 iming Diagrams Overview USA: (00) -IDEC or (0) , Canada () 17-IDEC

39 F Series Part Numbering List Part Numbers: F Mode of Rated Voltage Code Range Output Optional Complete Part Number -Pin 11-Pin OFF-delay AF0: 0 to 0VAC (50/0Hz) AD: V AC/DC 0.05 seconds to 00 seconds 50V AC, 5A, 0V DC, 5A (resistive load) 50V AC, 5A, 0V DC, A (resistive load) SPD DPD Reset None (p) Reset (11p) F-1AF0 F-1AD F-AF0 F-AD F-1EAF0 F-1EAD F-EAF0 F-EAD 1. Optional reset input resets the contact to the OFF state before time out. iming Diagrams/Schematics F-1 iming Diagrams ( ) 5 Reset (-) 1 F-1 (-pin) 7 (+) (ransistor ) 5 Reset (-) 1 SPD Output, with Reset 7 (+) Reset ( ) F-1E (11-pin) 5 7 Reset 9 (-) 1 11 (+) (ransistor ) (-) 1 11 (+) Item erminal No. () Reset In put (ON or L) -7 (p) - (11p) 1- (p) -7 (11p) 5- (p) 1- (11p) - (p) 1- (11p) r a s = a = Shorter than s = 1 Second r = Minimum Application F-1: 1 Second. For time ranges, see page -1.. For sockets and accessory part numbers, see page When power is applied, the NO output contact closes. When power is removed, the timing period begins. When time has elapsed, the NO contact opens. 5. For the timing diagram overview, see page -. USA: (00) -IDEC or (0) , Canada () 17-IDEC -9

40 F Series F- iming Diagrams F- (-pin) DPD Output ( ) F-E (11-pin) (ransistor ) (-) (+) Reset (-) (+) Reset (-) (+) -Pin ype Item erminal No. () = r = Minimum Application : 1 Second 11-Pin ype Item erminal No. r () Reset In put (ON or L) - -7 (11p) = a = Shorter than s = 1 Second r = Minimum Application : 1 Second r a s When power is applied, the NO contact closes. When power is removed, the timing period begins. When time has elapsed, the NO contact opens. Optional reset input will return contacts to original state before time elapses USA: (00) -IDEC or (0) , Canada () 17-IDEC

41 F Series Instructions: Setting F ➂ Setting Knob Steps 1. Select a time range that contains the desired period of time. Desired Base Ranges ➀ Dial Selector 0-1, 0-, 0-, 0-1, 0-0 ➀ Dial Selector 0.05s to 1s 0 to s to s 0 to 0.05s to s 0 to 0.1s to s 0 to 1 0.s to 0 0 to 0.s to 0 0 to 1.s to 10s 0 to 1 s to 00s 0 to 0. he set time is selected by turning the ➂ Setting Knob. Selection ➁ Range Selector 1S S Remarks range can be selected from 1S and S using a flat screwdriver and five different dials of 0 to 1, 0 to, 0 to, 0 to 1, and 0 to 0 are displayed in the six windows by turning the Dial Selector, allowing for selecting the best suited scale. Note that the switch does not turn infinitely. Setting Examples: ➁ Range Selector 1S, S 1) When the Setting Knob ➂ is set at.5, with Dial Selector ➀ 0 to and Range Selector ➁ 1S selected, then the set time is.5 seconds. ) When the Setting Knob ➂ is set at 5.0, with Dial Selector ➀ 0 to 0 and Range Selector ➁ S selected, then the set time is 500 seconds. USA: (00) -IDEC or (0) , Canada () 17-IDEC -1

42 F Series Instructions: Wiring s s of F o avoid electric shock, do not touch the input signal terminal during power voltage application. Never apply the input signals to two or more F timers using the same contact or transistor. Incorrect or ransistor Series r } erminal ~ Correct } erminal ~ Incorrect or ransistor D-7 } erminal ~ Correct or ransistor } erminal ~ } erminal } erminal } erminal } erminal In a transistor circuit for controlling input signals, with its primary and secondary power circuits isolated, do not ground the secondary circuit. Series r } erminal ~ Circuit Rectifier Circuit Insulating ransformer On the F timers, connect the input signals to terminal No.1 and only on the -pin type; connect the input signals to terminal No. and 7 only on the 11-pin type. Never apply voltage to other terminals; otherwise, the internal circuit may be damaged. signal lines must be made as short as possible and installed away from power cables and power lines. Use shielded wires or a separate conduit for input wiring. he F, consisting of a high-impedance circuit, may not be reset due to the influence of an inductive voltage or residual voltage caused by a leakage current. If not reset, connect an RC filter or bleeder resistor between power terminals so that the voltage between power terminals can be reduced to less than 15% of the rated voltage. - USA: (00) -IDEC or (0) , Canada () 17-IDEC

43 S Series (Star-Delta) Star-Delta Star Output Delta Output Star Setting Knob ➀ Star Dial Selector 0-5, 0-, 0-50, 0-0 ➁ Star-Delta Switching Selector 0.05 sec, 0.1 sec, 0.5 sec, 0.5 sec Mode Rated Voltage Range Output Part No. -pin ype Star-Delta AF0: 0 to 0V AC (50/0Hz) Star: 0.05 to 0 sec Star-Delta switching time: 0.05 sec 0.1 sec 0.5 sec 0.5 sec 50V AC/0V DC, 5A (resistive load) Star: SPS-NO Delta: SPS-NO Star: SPS-NO Delta: SPS-NO Instantaneous: SPS-NO S-1AF0 S-AF0 Ranges: ➀ Star Dial Selector Dial Range sec - 5 sec 0.05 sec sec - sec 0.1 sec sec - 50 sec 0.5 sec sec - 0 sec 0.5 sec ➁ Star-Delta Switching Selector UL c-ul Listed File No. E5599 Ratings: Ratings Mechanical Life Electrical 50V AC/0V DC, 5A (resistive load) 0,000,000 operations minimum 0,000 operations minimum (rated load) S able of Contents Specifications - Charts -5 Accessories -50 Instructions -5 Dimensions -5 iming Diagrams Overview - USA: (00) -IDEC or (0) , Canada () 17-IDEC -

44 S Series eneral Specifications System Solid state CMOS circuitry ype Star-delta Star side: 0.05 to 0 sec Range Star-delta switching time: 0.05, 0.1, 0.5, 0.5 sec Rated al Voltage 0 to 0V AC (50/0Hz) Operating emperature - to +50 C Storage emperature -0 to +0 C Operating Humidity 5 to 5% RH Voltage olerance 5 to V AC Repeat Error ±0.%, ± msec Voltage Error ±0.%, ± msec emperature Error ±0.%, ± msec Setting Error ±% maximum Reset 500 msec maximum Insulation Resistance 0MΩ minimum Between power and output terminals:,000v AC, 1 minute Dielectric Strength Between contacts of different poles:,000v AC, 1 minute Between contacts of the same pole: 750V AC, 1 minute Vibration Resistance 0 m/sec (Approx. ) Shock Resistance Operating extremes: 0m/sec (Approx. ) Damage limits: 500m/sec (Approx. 50) ype.0va (0V AC, 0Hz), S-1.VA (00V AC, 0Hz) Consumption (Approx.) ype S-.0VA (0V AC, 0Hz), 1.0VA (00V AC, 0Hz) - USA: (00) -IDEC or (0) , Canada () 17-IDEC

45 S Series Charts Product Series Internal Connection & erminal Arrangement Chart S-1 Star: SPS-NO Delta: SPS-NO (-pin ype) : Star contact -: Delta contact (11pin ype) Item erminal No. Star Delta -7 (p) - (11p) () 5- (p) 1- (11p) - (p) 9-11 (11p) Star Delta he star delayed contact goes on when power is turned on and goes off after a set time for the star contact ( 1 ). he delta delayed contact goes on after star-delta switching time ( ) and goes off when power is turned off. 1 = Star ON time (), = Star-delta switching time, = Delta ON time 1-: Star contact 9-11: Delta contact S- Star: SPS-NO Delta: SPS-NO Instantaneous SPS-NO (-pin ype) : Star contact -: Delta contact (11pin ype) Item erminal No. Star Delta Instantaneous -7 (p) - (11p) () 5- (p) 1- (11p) - (p) 9-11 (11p) 1- (p) -7 (11p) Star Delta : Star contact 9-11: Delta contact -7: Instantaneous contact he star delayed contact goes on when power is turned on and goes off after a set time for the star contact ( 1 ). he delta delayed contact goes on after star-delta switching time ( ) and goes off when power is turned off. he intantaneous contact goes on when power is turned on and goes off when power is turned off. 1 = Star ON time (), = Star-delta switching time, = Delta ON time USA: (00) -IDEC or (0) , Canada () 17-IDEC -5

46 W Series W Series Dual Range Key features of the W series include: Sequential start, sequential interval, on-delay, recycler, and interval ON timing functions time settings in one timer selectable operation modes on each model Mountable in sockets or flush panel and output status indicating LEDs ranges up to 00 hours NEW DESIN! c-ul Listed UL Listed File No.E5599 eneral Specifications System Solid state CMOS Circuit ype Multi-Mode Range 1: 0.1sec to hours, : 0.1sec to 00hours Pollution Degree (IE0-1) Over voltage category III (IE0-1) Rated al AF0 0-0V AC(50/0Hz) Voltage AD V AC(50/0Hz)/V DC AF0 5-V AC(50/0Hz) Voltage olerance AD 0.-.V AC(50/0Hz)/1.-.V DC D1.-1.V DC Disengaging value of Voltage Rated Voltage x% minimum Range of Ambient Operating emperature - to +50ºC (without freezing) Range of Ambient Storage and ransport emperature -0 to +75ºC (without freezing) Range of Relative Humidity 5 to 5%RH (without condensation) Atmospheric Pressure 0kPa to 1kPa (Operating), 70kPa to 1kPa (ransport) Reset 0msec maximum Repeat Error ±0.%, ±msec* Voltage Error ±0.%, ±msec* emperature Error ±0.%, ±msec* Setting Error ±% maximum Insulation Resistance 0MΩ minimum (500V DC) Between power and output terminals: 000V AC, 1 minute Dielectric Strength Between contacts of different poles: 000V AC, 1 minute Between contacts of the same pole:750v AC, 1 minute Vibration Resistance to 55Hz amplitude 0.75mm hours in each of axes Operating extremes: 9m/sec (approx.) Shock Resistance Damage limits: 90m/sec (approx. 50) times in each of axes Degree of Protection IP0 (enclosure), IP0 (socket) (IEC059) Consumption (Approx.) AF0 0V AC/0Hz 00V AC/0Hz.VA.VA AD (AC/DC) 1.VA/0.9W Mounting Position Free Dimensions 0Hx W x 70 mm Weight (Approx.) 7g ** For the value of the error against a preset time, whichever the largest. Ratings Allowable 90VA/W Allowable Voltage 50V AC/150V DC Allowable Current 5A Maximum permissible operating frequency 100 cycles per hour 1/HP, 0V AC A, 0V AC (Resistive) Rated Load 5A, V AC/0V DC (Resistive) Conditional Short Circuit Fuse 5A, 50V Life Electrical 0,000 op. minimum (Resistive) Mechanical 0,000,000 op. minimum W able of Contents Specifications - Part Number List -7 iming Diagrams / Schematics - Instructions: Setting r -9 Accessories -50 Instructions -5 Dimensions -5 iming Diagrams Overview USA: (00) -IDEC or (0) , Canada () 17-IDEC

47 W Series Part Number List Part Numbers Mode of Output Range* Rated Voltage Pin Configuration New Part Numbers pin W-A11AF0N 0 to 0V AC (50/0Hz) 11 pin W-A11EAF0N A: Sequential Start B: On-delay with course & fine C: Recycler & instaneous D: Recycler outputs (OFF Start) E: Recycler outputs (ON Start) F: Interval ON : Interval ON Delay H: Sequential Interval A, 0V AC 5A, V AC/0V DC (Resistive Load) SPD + SPD 1: 0.1sec - hours *(See Range Settings for details.) : 0.1sec - 00 hours V AC/DC 1V DC 0 to 0V AC (50/0Hz) V AC/DC pin W-A11ADN 11 pin W-A11EADN pin W-A11D1N 11 pin W-A11ED1N W-AAF0N pin W-AADN 1. For schematics, see page -.. For socket and accessory part number information, see page and 11-pin models differ only in the number of pins (extra pins are not used).. For the timing diagram overview, see page *For details on setting time ranges, see the instructions on page USA: (00) -IDEC or (0) , Canada () 17-IDEC -7

48 W Series iming Diagrams/Schematics -Pin 5 11-Pin (-) 7 1 (+) (-) (+) MODE chart MODE chart A : Sequential Start Item erminal No. -7(p) -(11p) Ry1 Ry 1-(p) 1-(11p) 1-(p) 1-(11p) 5-(p) -11(11p) -(p) 9-11(11p) OU1 OU E : Recycler outputs (ON Start) Item erminal No. -7(p) -(11p) Ry1 Ry 1-(p) 1-(11p) 1-(p) 1-(11p) 5-(p) -11(11p) -(p) 9-11(11p) OU1 OU B : On-delay with course and fine Item erminal No. -7(p) -(11p) Ry1 Ry 1-(p) 1-(11p) 1-(p) 1-(11p) 5-(p) -11(11p) -(p) 9-11(11p) OU1 OU 1 F : Interval ON Item erminal No. -7(p) -(11p) Ry1 Ry 1-(p) 1-(11p) 1-(p) 1-(11p) 5-(p) -11(11p) -(p) 9-11(11p) OU1 OU 1 C : Recycler and instaneous Item erminal No. -7(p) -(11p) Ry1 Ry 1-(p) 1-(11p) 1-(p) 1-(11p) 5-(p) -11(11p) -(p) 9-11(11p) OU1 OU : Interval ON Delay Item erminal No. -7(p) -(11p) Ry1 Ry 1-(p) 1-(11p) 1-(p) 1-(11p) 5-(p) -11(11p) -(p) 9-11(11p) OU1 OU D : Recycler outputs (OFF Start) Item erminal No. -7(p) -(11p) Ry1 Ry 1-(p) 1-(11p) 1-(p) 1-(11p) 5-(p) -11(11p) -(p) 9-11(11p) OU1 OU H : Sequential Interval Item erminal No. -7(p) -(11p) Ry1 Ry 1-(p) 1-(11p) 1-(p) 1-(11p) 5-(p) -11(11p) -(p) 9-11(11p) OU1 OU USA: (00) -IDEC or (0) , Canada () 17-IDEC

49 W Series Instructions: Setting W r Range Selector Mode Selector 1 Range Selector Setting Knob 1 Setting Knob 1. he switches should be securely turned using a flat screwdriver mm wide (maximum). Note that incorrect setting may cause malfunction. he switches, which do not turn infinitely, should not be turned beyond their limits.. Since changing the setting during timer operation my cause malfunction, turn power off before changing. Safety Precautions Special expertise is required to use Electronic. All Electronic r modules are manufactured under IDEC's rigorous quality control system, but users must add a backup or fail safe provision to the control system when using the Electronic r in applications where heavy damage or personal injury may occur should the Electronic r fail. Install the Electronic r according to instructions described in this catalog. Make sure that the operating conditions are as described in the specifications. If you are uncertain about the specifications, contact IDEC in advance. In these directions, safety precautions are categorized in order of importance to Warning and Caution. Warning Warning notices are used to emphasize that improper operation may cause sever personal injury or death. urn power off to the Electronic timer before starting installation, removal, Wiring, maintenance, and inspection on the Electronic r. Failure to turn power off may cause electrical shocks or fire hazard. Emergency stop and interlocking circuits must be configured outside the Electronic timer. If such a circuit is configured inside the Electronic r, failure of the Electronic timer may cause malfunction of the control system, or an accident. Caution Caution notices are used where inattention might cause personal injury or damage to equipment. he Electronic r is designed for installation in equipment. Do not install the Electronic r outside equipment. Install the Electronic r in environments described in the specifications. If the Electronic r is used in places where it will be subjected to high-temperature, high-humidity, condensation, corrosive gases, excessive vibrations, or excessive shocks, then electrical shocks, fire hazard, or malfunction could result. Use an IEC017-approved fuse and circuit breaker on the power and output line outside the Electronic r. Do not disassemble, repair, or modify the Electronic r. When disposing of the Electronic r, do so as industrial waste. USA: (00) -IDEC or (0) , Canada () 17-IDEC -9

50 Series Accessories Accessories: Series DIN Rail Mounting Accessories Part Numbers: DIN Rail/Surface Mount Sockets and Hold-Down Springs DIN Rail Mount Socket Applicable Hold-Down Springs Style Appearance Use with Part No. Appearance Part No. -Pin Screw erminal (dual tier) A-1,, (-pin) D-1,, (-pin) F-1, (-pin) W (-pin) S SRP Pin Screw erminal (dual tier) -Pin Fingersafe Socket A-1,, (11-pin) A-, 5, D-1,, (11-pin) D-, F-1, (11-pin) W (11-pin) A-1,, (-pin) D-1,, (-pin) F-1, (-pin) W (-pin) S SRP-05 SRP-05C SFA-0 11-Pin Fingersafe Socket -Pin Screw erminal A-1,, (11-pin) A-, 5, D-1,, (11-pin) D-, F-1, (11-pin) W (11-pin) A-1,, (-pin) D-1,, (-pin) F-1, (-pin) W (-pin) S SRP-05C SRP-0 11-Pin Screw erminal A-1,, (11-pin) A-, 5, D-1,, (11-pin) D-, F-1, (11-pin) W (11-pin) SRP-0 SFA-0 DIN Mounting Rail Length 00mm BNDN00 Installation of Hold-Down Springs DIN Rail Mount Socket Insert the springs into the outer slots with the projections facing inside. Insert the springs into the slots. Socket SRP-0 Hold Down Spring SFA-0 Socket SRP-05 Hold Down Spring SFA-0 Once installed into the sockets, the hold-down springs cannot be removed USA: (00) -IDEC or (0) , Canada () 17-IDEC

51 Series Accessories Panel Mounting Accessories Part Numbers: Panel Mount Sockets and Hold-Down Springs Panel Mount Socket Applicable HD Springs Style Appearance Use with Part No. Appearance Part No. -Pin Solder erminal A- (-pin) D- (-pin) W- (-pin) F- (-pin) S SRP-51 SFA-0 11-Pin Solder erminal A- (11-pin) D- (11-pin) W- (11-pin) F- (11-pin) SRP For information on installing the hold-down springs, see page -51. Part Numbers: Flush Panel Mount Adapter and Sockets that use an Adapter Accessory Description Appearance Use with Part No. Panel Mount Adapter Adaptor for flush panel mounting timers All timers RB-01 -pin screw terminal All -pin timers SRP-M0 Sockets for use with Panel Mount Adapter 11-pin screw terminal (Shown: SRP-M0 for Wiring Socket All 11-pin timers SRP-M11 Adapter) -pin solder terminal All -pin timers SRP-S0 11-pin solder terminal All 11-pin timers SRP-S11. No hold down springs are available for flush panel mounting. USA: (00) -IDEC or (0) , Canada () 17-IDEC -51

52 Series Instructions Instructions: Wiring s for Series s o avoid electric shock, do not touch the input signal terminal during power voltage application. When connecting the input signal terminals of two or more A timers to the same contact or transistor, the input terminals of the same number should be connected. (Connect erminals No. in common.) Incorrect or ransistor Series r Correct } erminal ~ } erminal ~ } erminal } erminal In a transistor circuit for controlling input signals, with its primary and secondary power circuits isolated, do not ground the secondary circuit. Series r } erminal ~ Circuit Rectifier Circuit Insulating ransformer Connect the input signal terminals of the A timers to erminal No. only. Never apply voltage to other terminals; otherwise, the internal circuit may be damaged. 5, and 7 erminals Ry ~ signal lines must be made as short as possible and installed away from power cables and power lines. Use shielded wires or a separate conduit for input wiring USA: (00) -IDEC or (0) , Canada () 17-IDEC

53 Series Instructions s Instructions: continued For contact input, use highly reliable gold-plated contacts to make sure that the residual voltage is less than 1V when the contacts are closed. A ype B ype 5 7 ResetStartate 9 (-) 1 11 (+mm) Start Reset (-) 5 7 For transistor input, use transistors with the following specifications; V CE = 0V, V CES = 1V or less, I C = 50 ma or more, and I CBO = 50µA or less. he resistance should be less than 1kΩ when the transistor is on. When the output transistor switches on, a signal is input to the timer. A ype Reset Startate (-) 1 11 (+) B ype Start Reset (-) (+) (+) s: A-1, -, - ransistor output equipment such as proximity switches and photoelectric switches can input signals if they are voltage/current output type, with power voltage ranges from 1 to 0V and have1v. When the signal voltage switches from H to L, a signal is input to the timer. ransistor Output Circuit ransistor 5, and 7 } erminals s: A-, -5, - he start input initiates a time-delay Start operation and controls output status. Reset ate When the reset input is activated, the time is reset, and contacts return to original state. he time-delay operation is suspended while the gate input is on (pause). No-voltage contact inputs and NPN open collector transistor inputs are applicable. V DC, 1mA maximum response time: 50msec maximum USA: (00) -IDEC or (0) , Canada () 17-IDEC -5

54 Series Dimensions Dimensions: Series N0.0 NOE: W series are UL Listed when used in combination with following IDEC's sockets: W-A11, A: SRP-0* pin type socket. W-A11E, A: SRP-05* pin type socket. (*-May be followed by A,B,C or U) he socket to be used with these timers are rated: -Conductor emperature Rating 0ºC min. -Use 1AW max.(mm max.) Copper conductors only -erminal orque 1.0 to 1. N-m Unit: mm Analog r, -Pin with SRP-0 Analog r, 11-Pin with SRP-0 1.5" (0mm) 1.5" (0mm) 1.0" (mm) 1.0" (mm) 0.1" (mm) 0.09" (1mm) When Mounting on DIN Rail BNDN:." (99mm) Maximum.71" (95mm) Maximum HD Spring SFA-0.5" (.mm) Digital r, -Pin with SRP-0.5" (.mm) 0.507" (1mm) 0.70" (1mm) 0.5" (mm) When Mounting on DIN Rail BNDN:.59" (9mm) Maximum." (mm) Maximum HD Spring SFA " (1mm) 0.70" (1mm) 0.5" (mm) DIN Rail 1." (1.7mm) 0.0" (1.7mm) 0.09" (1mm)." (0mm) DIN Rail 1." (1.7mm) 0.0" (1.7mm)." (0mm) 0.09" (1mm) 1.5" (0mm) 1.5" (0mm) 1.0" (mm) 1.0" (mm) 0.1" (mm) 0.09" (1mm) When Mounting on DIN Rail BNDN:." (99mm) Maximum.71" (95mm) Maximum HD Spring SFA-0.5" (.mm) Digital r, 11-Pin with SRP-0.5" (.mm) 0.507" (1mm) DIN Rail 0.0" (1.7mm) 1." (1.7mm) 0.70" (1mm) 0.09" (1mm) 0.5" (mm) When Mounting on DIN Rail BNDN:.59" (9mm) Maximum." (mm) Maximum HD Spring SFA " (1mm) 0.70" (1mm) 0.5" (mm)." (0mm) DIN Rail 1." (1.7mm) 0.0" (1.7mm)." (0 mm) 0.09" (1mm) Analog r, 11-Pin with SRP-05 Digital r, 11-Pin with SRP " (0mm) 1.0" (mm) 0.1" (mm) When Mounting on DIN Rail BNDN:.11" (5.5mm) Maximum.9" (1.5mm) Maximum 1.05" 1.9" (mm) (7mm)." (.mm).0" (5mm) 0.507" (1mm) 0." 0.117" (mm) (1.5mm) 0.7" (0mm) 1.11" (.5mm) HD Spring SFA-0 DIN Rail BNDN: 1.5" (0mm) 1.0" (mm) 0.09" (1mm) When Mounting on DIN Rail BNDN:." (9.5mm) Maximum." (9.5mm) Maximum 1.05" 1.9" (mm) (7mm)." (.mm) DIN Rail BNDN.0" (5mm) 0.507" (1mm) 0." (1.5mm) 0.117" (mm) 0.7" 1.11" (.5mm) (0mm) HD Spring SFA USA: (00) -IDEC or (0) , Canada () 17-IDEC

55 Series Dimensions DIN Rail Mount Sockets 11-Pin SRP-05 -Pin SRP-0.0" (5mm) 1." (mm) M.5" erminal Screw 0.1" (mm) Ø0.1 (Ø.mm) Mounting Hole erminal Arrangement 7 5.0" (0mm) 1.50" (0mm) 0.1" (mm) M.5 erminal Screw Ø 0.1" (Ø.mm) Mounting Hole erminal Arrangement " (mm) 1." (mm) op View 0.09" (1mm) 1.7" (mm) 7 1 op View 11-Pin SRP-0 -Pin SRP-05." (0mm).01" (59mm) 1.7" (mm) 0.1" M.5 erminal Screw erminal Arrangement (mm) 7 5 Ø 0.1" (Ø.mm) Mounting Hole op View.0" (5mm) 0.117" (mm) 1.0" () 1.11" (9mm) 0.0" (mm) M.5 erminal Screw f 0.01" (.mm) Mounting Hole erminal Arrangement op View Panel Mount Sockets -Pin with Solder erminal SRP-51 Dimensions in inches (mm) 1.95" (50mm) 1." (mm) 0.1" (.mm) 0." (mm) 1.1" (9mm) HD Spring SFA-0 Panel Surface erminal Arrangement Ø0.17" (.5mm) Drilled Holes (or M tapped holes) Ø 1.17" (0mm) 1." (mm) 1." (mm) 0.1" 0.9" (.5mm) 0.9" (11mm) (mm) Bottom View 11-Pin with Solder erminal SRP " (50mm) 1." (mm) 1." (mm) 0.1" (.mm) 0." (mm) HD Spring SFA-0 Panel Surface 1.1" (9mm) Ø 1.17" (0mm) 1." 1 11 (mm) 0.1" 0.9" (.5mm) 0.9" (11mm) (mm) erminal Arrangement Bottom View - Ø0.17" (.5mm) Drilled Holes (or M tapped holes) USA: (00) -IDEC or (0) , Canada () 17-IDEC -55

56 Series Dimensions Panel Mount Adapter Analog r, -Pin and 11-Pin with SRP-S0 or SRP-S11." (9mm) Maximum 1.7" mm) Panel Mount Adapter Panel hickness: 0.0" to 0." (0. to 5mm) 0.0" (1.7mm) 1.7" (.5mm) Digital r, -Pin and 11-Pin with SRP-S0 or SRP-S11." (9mm) Maximum 1.7" (mm) Panel Mount Adapter Panel hickness: 0.0" to 0." (0. to 5mm) 0.0" 1." (1.7mm) (.5mm 1.7" (mm) 0.9" (11mm).9" (1.mm) Wiring Socket Adapter 1.7" (mm) 0.1" (mm).9" (1.mm) Wiring Socket Adapter Mounting Hole Layout 1.7" 5mm) Single Mounting 1.7" (5mm) 1.7" (5mm) Horizontal Close Mounting 1.7"N 0.1" (N mm) olerance: + 0.0" (0.5mm) to 0. N: No. of Mounted Analog and Digital r, -Pin with SRP-M0 Panel hickness: 0.0" to 0." (0. to 5mm).1" (0.5mm) -M.5 erminal Screws 1.7" (.mm) 1.7" (.mm) " (7mm) 0." (9.mm) x " (0.mm) Ø 0.1" (.mm) Minimum 0." (mm) Maximum 0.17" (.5mm) Maximum 0.1" (5.mm) Minimum Analog and Digital r, 11-Pin with SRP-M11 11-M.5 erminal Screws 1.7" (5mm).51" (90mm) 1.7" (5mm) 1.19" (0.5mm) 1.7" (5mm) 0.7" (7mm) " (.5mm) x 1." (mm) Ø 0.1" (.mm) Minimum 0.9" (.9mm) Maximum 0.17" (.5mm) Maximum 0." (5.mm) Minimum -5 USA: (00) -IDEC or (0) , Canada () 17-IDEC

57 E1A Series E1A Series Single Function ON Delay Key features of the E1A series include: DPD or SPD + instantaneous SPD -pin, octal base time ranges Repeat error ±0.% maximum Large, clear knob for easy setting Instant monitoring of operational status by LED indicators E071 Specifications Rated Operating Voltage Voltage olerance Rating Form Repeat Error Voltage Error emperature Error Setting Error Reset Insulation Resistance Dielectric Strength Vibration Resistance V AC/DC 0 to V AC 0 to 0V AC AC: 5 to 1% DC: 90 to 1% 0V AC/5A V DC/5A DPD or SPD+ instantaneous SPD ±0.% ±msec maximum ±0.5% ±msec maximum ±% maximum ±% maximum 0.1 sec maximum 0MΩ minimum (500V DC megger) Between power and output terminals: 1,500V AC, 1 minute Between contact circuits: 750V AC, 1 minute Damage limits: Amplitude 0.75mm, to 55 Hz Operating extremes: Amplitude 0.5mm, to 55 Hz Shock Resistance Damage limits: 500m/s (Approx. 50) Consumption Electrical Life Mechanical Life Operating emperature Operating Humidity E1A-B E1A-C V AC type: 1. VA V DC type: 1.0W 1V AC type:. VA 0V AC type: 7.7 VA V AC type:.0 VA V DC type: 0.W 1V AC type:.5 VA 0V AC type:.0 VA 0,000 operations minimum (at full rated load),000,000 operations minimum to +55 C (without freezing) 5 to 5% RH (without freezing) E1A able of Contents Part Number List -5 iming Diagrams -5 E1A Accessories -59 E1A Dimensions -0 USA: (00) -IDEC or (0) , Canada () 17-IDEC -57

58 E1A Series Part Numbering List Mode of Output Rated Voltage Range Complete Part No. V AC/DC E1A-BMAD 1-V AC 0.1s to m E1A-BMA1 SPD + Instantaneous SPD 0-0V AC E1A-BMA0 V AC/DC E1A-BHAD ON-Delay V DC/ V AC, 5A 0V AC, 5A 1-V AC 0.1m to h E1A-BHA1 0-0V AC E1A-BHA0 V AC/DC E1A-CMAD 1-V AC 0.1s to m E1A-CMA1 DPD 0-0V AC E1A-CMA0 V AC/DC E1A-CHAD 1-V AC 0.1m to h E1A-CHA1 0-0V AC E1A-CHA0 iming Diagrams/Schematics Mode Selection E1A-B SPD + Instantaneous SPD 5 E1A-C DPD 5 (-) 1 7 (+) (-) 1 7 (+) ON-Delay 1 MODE A Item () -7 (p) Instantaneous erminal No. 5- (p) - (p) 1-1- OU Item erminal No. -7 (p) () 1-, 5- (p) 1-, - (p) OU -5 USA: (00) -IDEC or (0) , Canada () 17-IDEC

59 E1A Series Accessories Mounting Accessories Style Appearance Part No. -Pin Screw erminal (dual tier) SRP-05 DIN Rail/ Surface Mounting Accessories -Pin Fingersafe Socket -Pin Screw erminal SRP-05C SRP-0 DIN Mounting Rail Length 00mm BNDN00 -Pin Solder erminal SRP-51 Panel Mounting Accessories Screw erminal Socket SRP-M0 Panel Mount Adapter E9Z-AD Other Accessories Style Appearance Part No. Dust Cover E9Z-C USA: (00) -IDEC or (0) , Canada () 17-IDEC -59

60 E1A Series Dimensions: E1A Series E1A r Pin SRP-05 M S X1 X E1A.0 Ø5.0 OU..0.0" (5mm) 1.0" () 0.0" (mm) M.5 erminal Screw f 0.01" (.mm) Mounting Hole erminal Arrangement " (mm) 1.11" (9mm) 1 op View 9. -Pin SRP-0 Dimensions in inches (mm) " (0mm) 1.50" (0mm) 0.1" (mm) M.5 erminal Screw Ø 0.1" (Ø.mm) Mounting Hole erminal Arrangement " (1mm) 1.7" (mm) 7 1 op View E1A r Panel Cutout 5.0 (+0., 0) 5.0 (+0., 0) -0 USA: (00) -IDEC or (0) , Canada () 17-IDEC

61 5P Series 5P Series ON Delay Key features of the 5P series include: SPD, 5A contacts -pin, octal base 9 time ranges Repeat error ±0.% maximum Control settings by hand or screwdriver ON and timing out LED indicators Uses the same sockets and hold down clips as IDEC s RRP -pin relays UL Recognized File No. E5599 CSA Certified File No. LR09 Specifications Rated Operating Voltage Voltage olerance Rating Resistive load Inductive load Allowable (resistive load) Form Voltage Repeat Error Voltage Error emperature Error Setting Error Reset Insulation Resistance Dielectric Strength 0 to V AC (50/0Hz) 00 to 0V AC (50/0Hz) V AC/DC 1V DC AC type: ±15% DC type: ±% (ripple % maximum) V AC/V DC, 5A 0V AC, A 0V AC, 0.A V AC, 1.A V DC, 1.7A 90VA AC W DC SPD 50V AC, 150V DC ±0.% ±msec ±0.5% ±msec ±% maximum (over to 50 C, reference temperature 0 C) ±% maximum When turning power off after time up: 0.1 sec maximum When turning power off before time up: 1 sec maximum 0MΩ minimum 000V AC, 1 minute (except between contacts of the same pole) Vibration Resistance 0N (approximate ) Shock Resistance Consumption Electrical Life Mechanical Life Operating emperature Operating Humidity 1.Inductive load (reference), cosθ =. to. or L/R=15msec..Minimum applicable load: 5VDC/mA (reference). Operating extremes: 0N (approximate ) Damage limits: 500N (approximate 50) 0V AC type: 1.5VA (at 50Hz) 00V AC type: 1.VA (at 50Hz) V DC type: 0.9W 0,000 operations minimum (at rated load) 0,000,000 operations minimum to +50 C 5 to 5% RH 5P able of Contents Specifications -1 Part Numbering List - iming Diagrams / Schematics - 5P Accessories - 5P Dimensions -5 iming Diagrams Overview - USA: (00) -IDEC or (0) , Canada () 17-IDEC -1

62 5P Series Part Numbering List Mode of Output Rated Voltage Range Complete Part No. 1S S 5P-NSA0 S 0 to V AC S 0S 0S 5P-NSA0 5P-N0SA0 5P-N0SA0 M 5P-NMA0 M 5P-NMA0 M 5P-NMA0 1S 5P-N1SA00 S S 5P-NSA00 00 to 0V AC S 0S 0S 5P-NSA00 5P-N0SA00 5P-N0SA00 ON-Delay SPD V DC/ V AC, 5A 0V AC, A M M M 5P-NMA00 5P-NMA00 5P-NMA00 1S 5P-N1SAD S S 5P-NSAD S 5P-NSAD V AC/DC 0S 0S 5P-N0SAD M M 5P-NMAD M 5P-NMAD 1S S S S 5P-NSD1 1V DC 0S 5P-N0SD1 0S 5P-N0SD1 M M M 5P-NMD1 For sockets and accessories, see page USA: (00) -IDEC or (0) , Canada () 17-IDEC

63 5P Series iming Diagram/Schematic/Electrical Life Curves SPD 5 Mode (-) 1 7 (+) Do not apply voltage to terminals 1,, and. Item erminal No. () -7 ON-Delay 5- - OU Electrical Life Curves Life (x,000 operations) V DC Resistance Load V AC Resistance Load 0V AC Resistance Load V DC Induction Load V AC Induction Load 0V AC Induction Load Load Current (A) USA: (00) -IDEC or (0) , Canada () 17-IDEC -

64 5P Series Accessories Mounting Accessories Part Numbers: Mounting Accessories and Sockets Applicable Hold-Down Springs Style Appearance Use with Part No. Appearance Part No. -Pin Screw erminal (dual tier) 5P SRP-05 SFA-0 -Pin Fingersafe Socket 5P SRP-05C DIN Rail/ Surface Mounting Accessories -Pin Screw erminal 5P SRP-0 SFA-0 DIN Mounting Rail Length 00mm BNDN00 Panel Mounting Accessories Part Numbers: Mounting Accessories and Sockets Applicable Hold-Down Springs -Pin Solder erminal SRP-51 SFA-0 Installation of Hold-Down Springs DIN Rail Mount Socket Insert the springs into the outer slots with the projections facing inside. Socket SRP-0 Hold-Down Spring SFA USA: (00) -IDEC or (0) , Canada () 17-IDEC

65 5P Series Accessories Dimensions: 5P Series -Pin SRP " () 0.0" (mm) M.5 erminal Screw erminal Arrangement 5.0" (5mm) f 0.01" (.mm) Mounting Hole " (mm) 1.11" (9mm) op View 1 Dimensions in inches (mm) -Pin SRP " (0mm) 0.1" (mm) erminal Arrangement 5.0" (0mm) M.5 erminal Screw Ø 0.1" (Ø.mm) Mounting Hole " 0.09" (1mm) 1.7" (mm) 5P r, -Pin with SRP op View When Mounting on DIN Rail BNDN:.9" () Maximum 1." () 1.1" (9) 0.7" (7)." (9) Max. 1.9" ()." ().9" (75) 0.507" (1) HD Spring SFA " (5) 0." (1.5) 0.7" (0) 1.11" (.5) DIN Rail BNDN:.0" (5) 0.117" () 5P r, -Pin with SRP-0 1." () 1.1" (9) 0.7" (7) When Mounting on DIN Rail BNDN:.7" (95.5) Maximum.55" (91) Maximum HD Spring." ().9" (75) 0.507" (1) DIN Rail 0.0" (1.7) 1." (1.7) 0.70" (1) 0.09" (1) 0.5" ()." (0) USA: (00) -IDEC or (0) , Canada () 17-IDEC -5

66 5Y Series 5Y Series ON Delay Key features of the 5Y series include: PD, A or DPD, 5A contacts time ranges Repeat error ±0.% maximum Control settings by hand or screwdriver ON and timing out LED indicators Uses the same sockets and hold-down clips as IDEC s RYS and RU series relays UL, c-ul Listed File No. E5599 Specifications Rated Operating Voltage 5Y- 0 to V AC (50/0Hz) 00 to 0V AC (50/0Hz) V DC V AC 1V DC 5Y- Form DPD PD Rated Load Allowable Resistive Load Inductive Load Resistive Load Inductive Load Cos Ø = 0. L/r = 7msec 0V AC, 5A 0V DC, 5A 0V AC, A 0V DC,.5A 10VA AC 150W DC 0VA AC 75W DC 0V AC, A 0V DC, A 0V AC, 0.A 0V DC, 1.5A 0VA AC 90W DC 17VA AC 5W DC Allowable Voltage 50V AC, 15V DC Allowable Current 5A A emperature Error ±% maximum (over to 50 C, reference temperature 0 C) Setting Error ±% maximum Reset Insulation Resistance Dielectric Strength When turning power off after time up: 0.1 second maximum When turning power off before time up: 1 second maximum 0MΩ minimum Vibration Resistance 0N (approximate ) Shock Resistance Consumption Electrical Life,000V AC, 1 minute (except between contacts of the same pole) Operating extremes: 0N (approximate ) Damage limits: 500N (approximate 50) 0V AC type: 1.5VA (at 50Hz) 00V AC type: 1.VA (at 50Hz) V DC type: 0.9W 500,000 operations minimum (0V AC, 5A) 00,000 operations minimum (1V AC, A) Mechanical Life 50,000,000 operations minimum 50,000,000 operations minimum Operating emperature to +50 C Operating Humidity 5 to 5% RH 1. Minimum applicable load: 5Y-: 5V DC, 0mA (reference value); 5Y-: 5V DC, ma (reference value).. Inductive load: cosθ =., L/R=7msec. 5Y able of Contents Part Number List -7 iming Diagrams - 5Y Accessories -9 5Y Dimensions USA: (00) -IDEC or (0) , Canada () 17-IDEC

67 5Y Series Part Numbering List Mode of Output Rated Voltage ON-Delay DPD PD 0V AC/ 0V DC, 5A 0V AC/ 0V DC, A 0 to V AC 00 to 0V AC 1V DC V DC V AC 0 to V AC 00 to 0V AC 1V DC V DC V AC 1. For sockets and accessories, see page -9. Range 1S/S/1M/M S/0S/M/0M S/0S/M/0M 1S/S/1M/M S/0S/M/0M S/0S/M/0M 1S/S/1M/M S/0S/M/0M S/0S/M/0M 1S/S/1M/M S/0S/M/0M S/0S/M/0M 1S/S/1M/M S/0S/M/0M S/0S/M/0M 1S/S/1M/M S/0S/M/0M S/0S/M/0M 1S/S/1M/M S/0S/M/0M S/0S/M/0M Complete Part No. 5Y-SN1A0 5Y-SNA0 5Y-SNA0 5Y-SN1A00 5Y-SNA00 5Y-SNA00 5Y-SN1D1 5Y-SND1 5Y-SND1 5Y-SN1D 5Y-SND 5Y-SND 5Y-SN1A 5Y-SNA 5Y-SNA 5Y-SN1A0 5Y-SNA0 5Y-SNA0 5Y-SN1A00 5Y-SNA00 5Y-SNA00 1S/S/1M/M S/0S/M/0M 5Y-SND1 S/0S/M/0M 1S/S/1M/M S/0S/M/0M S/0S/M/0M 1S/S/1M/M S/0S/M/0M S/0S/M/0M 5Y-SN1D 5Y-SND 5Y-SND 5Y-SN1A 5Y-SNA 5Y-SNA iming Ranges Range Code Scale Indication Range 1S x 0.1 S 0.1 second to 1 second S x 1 S 0. second to seconds 0 to 1M x 0.1 M 1. seconds to 1 minute M x 1 M 1 seconds to minutes S x 1 S 0.1 second to seconds 0S x S 0.5 second to 0 seconds 0 to M x 1 M seconds to minutes 0M x M 0 seconds to 0 minutes S x 1 S 0.1 second to seconds 0S x S 1 second to 0 seconds 0 to M x 1 M seconds to minutes 0M x M 1 minute to 0 minutes USA: (00) -IDEC or (0) , Canada () 17-IDEC -7

68 5Y Series iming Diagram/Schematics/Electrical Life Curves 5Y- DPD 5Y- PD Internal Connections (bottom view) (-) (+) (-) (+) 1 Mode: ON-Delay Item erminal No. () , -, -11, , -, 7-11, -1 OU For an explanation of timing modes, see page E-. Electrical Life Curves 5000 Life (x,000 operations) V AC Resistance Load 0V AC Resistance Load 1V AC Induction Load AC Load 5Y- 5Y- 0V AC Induction Load 1 5 Load Current (A) 5000 Life (x,000 operations) DC Load 0V DC Resistance Load 5Y- 5Y- 0V DC Induction Load 0V DC Resistance Load 0V DC Induction Load 1 5 Load Current (A) - USA: (00) -IDEC or (0) , Canada () 17-IDEC

69 5Y Series Accessories DIN Rail Mounting Accessories Part Numbers: DIN Rail/Surface Mount Sockets and Hold-Down Springs DIN Rail Mount Socket Applicable Hold-Down Springs Style Appearance Part No. Appearance Part No. 1-Blade Screw erminal SYS-05 SFA-0 1-Blade Screw erminal (fingersafe) SYS-05C DIN Mounting Rail Length 00mm BNDN00 Panel Mounting Accessories Part Numbers: Panel Mount Socket and Hold-Down Springs Panel Mount Socket Applicable Hold-Down Springs Style Appearance Part No. Appearance Part No. 1-Blade Solder erminal SYS-51 SFA-0 PCB Mounting Accessories Part Numbers: PCB Mount Sockets with Applicable Hold-Down Springs PCB Mount Socket Applicable Hold-Down Springs Style Appearance Part No. Appearance Part No. 1 Blade, PCB erminal SYS-1 SFA-0 1 Blade, PCB erminal SYS- SYS-0F1 USA: (00) -IDEC or (0) , Canada () 17-IDEC -9

GT3D Series Digital Timers

GT3D Series Digital Timers rs D Series D Series rs Key features of the D series include: Precise time setting using digital thumbwheel switches Elapsed or time remaining LED display time ranges, timing functions delays up to. hours

More information

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range GT3A Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEDs UL,

More information

Switching & Controls Timers

Switching & Controls Timers Switching & Controls imers Selection Guide...792 RE Series Analog imers... 798 Accessories...803 Dimensions...804 G3A Series Analog imers... 805 G3D Digital imers...813 G3F Series rue OFF Delay imers 826...

More information

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13. GT3A GT3A Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEDs

More information

Timers RTE. RTE Series Analog Timers

Timers RTE. RTE Series Analog Timers RTE RTE Key features: 20 time ranges and 10 timing functions Time delays up to 600 hours Space-saving package High repeat accuracy of ± 0.2% ON and timing OUT LE indicators Standard 8- or 11-pin and 11-blade

More information

GT3W Series Dual Time Range Timers. CSA Certified File No.LR58183 LR96764 LR83814

GT3W Series Dual Time Range Timers. CSA Certified File No.LR58183 LR96764 LR83814 TW Series Courtesy of Steven Engineering, Inc. 0 Ryan Way, South San Francisco, CA, 00-70 Main Office: (50) 5-00 Outside Local Area: (00) 5-00 www.steveneng.com Specifications Time Range Rated Voltage

More information

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web:  - Key features: True power OFF-delay up to minutes No external control switch necessary Available with reset inputs Mountable in sockets or flush panel Specifications Operation UL, c-ul Listed File No. E55996

More information

GT5Y Series ON Delay Timers. UL, c-ul Listed File No. E V AC, 3A 30V DC, 3A 220V AC, 0.8A 30V DC, 1.5A 660VA AC 90W DC 176VA AC 45W DC

GT5Y Series ON Delay Timers. UL, c-ul Listed File No. E V AC, 3A 30V DC, 3A 220V AC, 0.8A 30V DC, 1.5A 660VA AC 90W DC 176VA AC 45W DC TY Series TY Series ON Delay Key features of the TY series include: PDT, 3A or DPDT, A contacts time ranges Repeat error ±0.2% maximum Control settings by hand or screwdriver Power ON and timing out LED

More information

GT3D Digital Timers. 100 to 240V AC (50/60Hz), 24V AC (50/60Hz)/24V DC

GT3D Digital Timers. 100 to 240V AC (50/60Hz), 24V AC (50/60Hz)/24V DC rs G3D Series G3D rs Key features of the G3D series incude: Precise time setting using digita thumbwhee switches Eapsed or time remaining LCD dispay 6 time ranges, 16 timing functions deays up to 99.9

More information

Timers GE1A. GE1A Series ON Delay Timers Single Function

Timers GE1A. GE1A Series ON Delay Timers Single Function Key features: DPDT or SPDT + instantaneous SPDT 8-pin, octal base 8 time ranges Repeat error ±0.2% maximum Large, clear knob for easy setting Instant monitoring of operational status by LED indicators

More information

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features: RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator

More information

Timing Mode Supply Voltage Trigger Options Reset Options Outputs Cat. No V AC Power On Power Off. Repeat Cycle OFF-Start

Timing Mode Supply Voltage Trigger Options Reset Options Outputs Cat. No V AC Power On Power Off. Repeat Cycle OFF-Start Bulletin -HR Plug-in iming Relays Product election/catalog Number Explanation Bulletin ON-Delay iming Relays ocket or Panel Mounted iming Range From. s h -pin base for socket cat. nos. -HN, -HN, -HN rigger:

More information

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13. G3 G3 Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEs Specifications

More information

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection RY/RM Series Miniature Relays Key features: RY (A), RY (A), RM (A) General purpose miniature relays A or A contact capacity Wide variety of terminal styles and coil voltages meet a wide range of applications

More information

DIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS

DIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS DIN SIZE ANALOG MULI-ANGE CYCLIC WIN IMES UL File No.: E122222 CSA File No.: L39291 FEAUES A single twin timer unit that repeats (variable) ON/OFF. Multiple ranges with a.1 s to 5 h time specification

More information

MULTI-RANGE ANALOG TIMER

MULTI-RANGE ANALOG TIMER MULI-RANGE ANALOG IMER PM4S imers PM4S RoHS Directive compatibility information http://www.nais-e.com/ Features 1. Economic pricing that promptly reflects market demands Remarkable economic pricing is

More information

RJ Series Slim Power Relays

RJ Series Slim Power Relays RJ Series RJ Series Slim Relays Circuit Breakers Terminal Blocks Timers Display Lights Switches & Pilot Lights Compact and rugged power relays. Large switching capacity. Compact housing only.7-mm wide.

More information

For more information, please visit or call toll free at

For more information, please visit   or call toll free at GT3 GT3 Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEs UL,

More information

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No. RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in

More information

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Solid-state Timer CSM DS_E_

More information

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection. Blade Terminal

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection. Blade Terminal RH Key features SPDT through PDT, 0A contacts Compact power type relays Miniature power relays with a large capacity 0A contact capacity Compact size saves space Contact SPDT PDT PDT RH Series Compact

More information

DIN48 SIZE MULTI-RANGE ANALOG TIMER. Protective construction. Time range IP65 IP50 IP selectable ranges 1s to 500h IP50 IP65 IP50

DIN48 SIZE MULTI-RANGE ANALOG TIMER. Protective construction. Time range IP65 IP50 IP selectable ranges 1s to 500h IP50 IP65 IP50 12 Socket mount PRODUC YPE ype 62.5 2.461 Operation mode DIN SIZE MULI-RANGE ANALOG IMER mm inch Flush mount 8 operation modes Pulse -delay Pulse Flicker Pulse -flicker Differential /-delay (1) (2) Signal

More information

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2 for Low Voltage, and EMC Directives. Approved by UL and CSA. Lloyds/NK approvals.

More information

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection Relays 22 Technical Data...1 Specifications...2 Model Number Structure - Relays...3 Model Number Selection... 4-5 Electrical Characteristics...6 Accessories...7 Dimensions...8 Instructions...10 Safety

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2. Conforms to EMC standards (EN50081-2 and EN50082-2). Approved by UL and CSA. Lloyds/NK

More information

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291 COMP SIZE HIGH PRECISI IMERS VARIOUS OUPU & OPERAI MODE YPES SDX (one) SDX imers Features UL File No.: E22222 CSA File No.: LR3929 3 operation modes added for fuller lineup Now, operation modes include

More information

T ime Delay Relays General information

T ime Delay Relays General information General information Time delay relays FUJI time delay relays feature top performance and dependability. These compact industrial time delay relays are specifically designed for process control, machine

More information

onlinecomponents.com

onlinecomponents.com General information Time delay relays FUJI time delay relays feature top performance and dependability. These compact industrial time delay relays are specifically designed for process control, machine

More information

onlinecomponents.com

onlinecomponents.com Key features: Relay Barrier: Intrinsically Safe Explosion-Proof: EB3C Relay [Exia] II C IEC0079 compliant Dry-contact switches can be connected to the EB3C 8- and 1-circuit types are available in common

More information

Multi Function Timer with Free power, Compact size W38 H42mm

Multi Function Timer with Free power, Compact size W38 H42mm Multi Function with Free power, ompact size W8 H4mm Features Wide power supply range : 100-40VA 50/0Hz, 4-40VD (universal), 4VA 50/0Hz / 4VD (universal), 1VD Various output operations( operation modes)

More information

Solid-state Timer H3DE

Solid-state Timer H3DE Solid-state Timer H3DE DIN-rail Mounted, Standard 22.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/DC) reduces the number of timer models kept in stock. (except for H3DE-H) 12-VDC

More information

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts) IDEC RJ22 Series Slim Relays (Bifurcated Contacts) Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) High contact

More information

Solid-State Digital Counter H7AN

Solid-State Digital Counter H7AN Solid-State Digital Counter Preset and Totalizing Counters with Up to 8-Digit LED Displays Draw-out construction allows setting, servicing without disconnecting wiring Choose from selectable UP/DOWN or

More information

Bulletin 700-HX Multifunction Digital Timing Relay

Bulletin 700-HX Multifunction Digital Timing Relay Bulletin 700-HX Multifunction Digital Timing Relay Model Operating Mode Timing Range Socket Type Contact Output No. of Pins Input Voltage Cat. No. Cat. No. 700 HX A mode: Signal ON-Delay 1 A-1 mode: Signal

More information

Timers/Time Switches/Counters/Hour Meters

Timers/Time Switches/Counters/Hour Meters 0 0 imers/ime Switches/Counters/Hour Meters MUI-RANGE ANAOG IMER PMS imers PMS Features. Economic pricing that promptly reflects market demands Remarkable economic pricing is implemented in pursuit of

More information

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive RFV RFV -Pole Force Guided Relays/SJ Series Relay Sockets Key features: -pole force guided relay to reduce cost and installation space. Force guided contact mechanism (EN00 Type A TÜV approved). Reinforced

More information

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2SES SEN TRONIC AG [3] OUTPUT Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL

More information

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS 20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,

More information

Solid-state Twin Timer

Solid-state Twin Timer Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time

More information

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01 Monitoring Relays rue RMS 3-Phase, 3-Phase+, Multifunction ypes DPC01, PPC01 DPC01 Product Description 3-phase or 3-phase+neutral line voltage monitoring relay for phase sequence, phase loss, asymmetry,

More information

Analog Timer TTL Series

Analog Timer TTL Series Analog r TTL Series Part Number Description TTL - ❶ ❷ ❸ ❶ Pin Type 8 : 8Pin Socket and Panel mounted ❷ Timing Mode A : A, A1, F1, I B : A, A1, B, F ❸ Supply Voltage 110/220VAC 24VDC 110VDC General Specification

More information

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays. Miniature Power Relays CSM DS_E_1_1 Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays Relays with AC and DC coils have different colors of operating indicators

More information

6mm Interface Relays RV8 Series

6mm Interface Relays RV8 Series 6mm Interface Relays RV8 Series PRODUCT DESCRIPTION Electromechanical C1D2 (screw terminal) Solid State (spring clamp) IDEC 6mm interface relays provide a compact solution for general purpose relay requirements.

More information

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6). Power PCB Relay Subminiature 20 L x 9.90 W x 9.90 H mm (0.79 L x 0.39 W x 0.39 H in) Low power consumption (200 mw) Sealed construction permits automatic soldering and cleaning of the PC board High-capacity

More information

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm. Series Digital LCD Timer DIN W48 H48mm Features Power supply : 4-4VAC 5/6Hz, 4-4VDC universal Easy to switch Up/Down mode programmable output modes and timing ranges () Selectable function by front digital

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to 230 VAC/VDC

More information

Slim compact safety relay

Slim compact safety relay Slim compact safety relay SF RELAYS Slim type Max..9 Max..9 Max.. Max..99 Max.. Max.. mm inch FEATURES Forcibly guide contact structure (EN Class A TÜV recognized) Slim profile (mm inch) Compact size with

More information

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V 20 AMP POWER RELAY HG RELAYS a 3 1.4 5 RoHS Directive compatibility information http://www.nais-e.com/ a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A 250 V AC resistive and 1.5 kw 3 phase 220 V AC motor

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj Ratchet Relay Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation Each contact in the double-pole contact mechanism performs alternate make-brake operation at each pulse input

More information

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal 83 Modular timers 12-16 A 83 Multi-function timer range 83.01 - Multi-function & multi-voltage, 1 Pole 83.02 - Multi-function & multi-voltage, 2 Pole (timed + instantaneous options), external time setting

More information

WHEN A PLC IS TOO MUCH, AND SPACE FOR

WHEN A PLC IS TOO MUCH, AND SPACE FOR WHEN A PLC IS TOO MUCH, AND SPACE FOR A RELAY SEQUENCE CIRCUIT IS TOO LITTLE Pattern Selector 59 2.33 66 2.6 70 2.75 No programming required Select from among 15 preset patterns Wiring far simpler than

More information

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type Slim type safety relays SF RELAYS Slim type RoHS compliant Protective construction: Flux-resistant type ORDERING INFORMATION S: Slim type Contact arrangement 2: 2 Form A 2 Form B 3: 3 Form A Form B 4:

More information

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI General-purpose Relay CSM_GR-_-S_DS_E Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped

More information

SLIM COMPACT SAFETY RELAY

SLIM COMPACT SAFETY RELAY SLIM COMPACT SAFETY RELAY SF-RELAYS Slim type Max. 24.945 Max. 24.945 Max. 4.575 Max. 5.969 Max. 3.52 Max. 3.52 mm inch FEATURES Forcibly guide contact structure (EN525 ClassA TÜV recognized) Slim profile

More information

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550 UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY K-RELAYS.0 a UL File No.: E3 CSA File No.: LR2550.0.8 00 times more reliable than similar designs Extra long life Mechanical: more than 0 8 operations Electrical

More information

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

PARM-SIZED, 16-CHANNEL RELAY TERMINALS Pressure connector connect type Wire-direct connect type PARM-SIZED, -CHANNEL RELAY TERMINALS FEATURES Compact, space-saving design: The Relay Terminal with I/O channels measures only (W) (D) (H) mm (W).

More information

Control Relays and Timers

Control Relays and Timers Control Relays and Timers Universal TR Series TR Series.8 Product Selection Guide......................................... 2 Product Overview.............................................. 3 Universal TR

More information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks -A Load Compact: 20 x 15 x 10 mm (L x W x H). Low power consumption: 200 mw. Flux protection or plastic-sealed construction available.

More information

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval Solid-State Timer Analog Set Multifunction Timers in Slim Design for Track Mounting All settings are made though front panel Six operating modes in a single timer provides flexibility for many applications

More information

Power supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits)

Power supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits) Controller CSM DS_E_3_1 Offers High-speed Input Response of 0.1 ms and Equipped with Built-in imer High-speed response of 0.1 ms. Ideal as a two-input Controller. Lineup includes the -BK with flip-flop

More information

Relays & Sockets. Switching & Controls.

Relays & Sockets. Switching & Controls. Switching & Controls For more information on this product family, visit our website. Additional resources include: New and updated product information Downloadable software demos & upgrades Part confi

More information

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation General Purpose Relays MKS Exceptionally Reliable General Purpose Relay now available with Lockable Test Button IEC Rating of A 0 V AC 0/0 Hz, General use 100,000 cycles. Mechanical indicator standard

More information

This document provided by Barr-Thorp Electric Co., Inc

This document provided by Barr-Thorp Electric Co., Inc Switching & Controls For more information on this product family, visit our website. Additional resources include: New and updated product information Downloadable software demos & upgrades Part confi

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS Timers DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to

More information

27/04/2015

27/04/2015 Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement

More information

DIN 48 SIZE DIGITAL TIMER. UL File No.: E C-UL File No.: E122222

DIN 48 SIZE DIGITAL TIMER. UL File No.: E C-UL File No.: E122222 DIN SIZE DIGITAL TIME 4..9 mm inch 8-pin type -pin type Screw type Product types UL File No.: E C-UL File No.: E Features Wide time range The operation time range covers from 0.0 sec. to 9999 hours. The

More information

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer OMRON Analog Set Multifunction Timers Series To view data sheets, click on any link below: - Standard Timer -G - Star-Delta Timer -F - Twin Timer -H - Power OFF- Delay Timer Multifunction Timer Analog

More information

Programmable Digital Timer

Programmable Digital Timer Programmable Digital imer Digital 7-egment display upply Voltage range of 110-240 VAC Input ignal ensing range of 85-265 VAC/100-265 VDC & 20-60 VAC/DC Inbuilt library of 33 functions covering majority

More information

MODEL: M2DYS SEN TRONIC AG

MODEL: M2DYS SEN TRONIC AG Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical

More information

Panasonic products. SIngle function-multirange Multifunction single-range Multifunction-multirange. Precise High quality.

Panasonic products. SIngle function-multirange Multifunction single-range Multifunction-multirange. Precise High quality. Panasonic products SIngle function-multirange Multifunction single-range Multifunction-multirange Precise High quality Reliable Robust Table of Contents General Information Timers Timers Chart Overview

More information

Relays & Sockets. General-purpose electromechanical relays and sockets

Relays & Sockets. General-purpose electromechanical relays and sockets Relays & Sockets General-purpose electromechanical relays and sockets Relays (Selection Guide) Category Slim Power Relay Model RJ RJ PC Board Terminal General SPDT, DPDT: A or A contact RoHS directive

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS CSM_H3DS_DS_E_2_1 DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock.

More information

Electronic timers CT-S range Selection and ordering details

Electronic timers CT-S range Selection and ordering details CT-S range Selection and ordering details Characteristics CT-S range CT-MFS 1SVR 430 010 F 0200 3 multifunction and 21 multi-range Continuous supply voltage range (24-240VAC/DC) or multisupply voltage

More information

DIN 48 SIZE DIGITAL TIMER. UL File No.: E C-UL File No.: E122222

DIN 48 SIZE DIGITAL TIMER. UL File No.: E C-UL File No.: E122222 DIN SIZE DIGIAL L4H/-L imers L4H imers Pin type 4..9 mm inch Screw terminal type RoHS Directive compatibility information http://www.nais-e.com/ UL File No.: E C-UL File No.: E Features. Bright and Easy-to-Read

More information

TV-15, 30 AMP (1 Form A) Power Relay

TV-15, 30 AMP (1 Form A) Power Relay VDE TV-, 3 AMP ( Form A) Power Relay RELAYS Form A Plug-in type Form A type also available with 48A contact capacity FEATURES. Excellent resistance to contact welding Owing to the pre-tension and kick-off

More information

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO New Product News G9EJ--E Compact Capable of Switching 4 V A DC loads Actualize a high capacity interruption through the function of extinction of magnetic arc by adopting high-efficiency magnetic circuit.

More information

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples. Miniature High Capacity Relays with SPST-NO 0A and SPST-NO + SPST-NC A SPST-NO 0A and SPST-NO + SPST-NC A for power switching and output that satisfy the needs for space-saving. Small High-capacity Relays

More information

Relays. Switching & Controls. Selection Guide

Relays. Switching & Controls.   Selection Guide Switching & Controls Selection Guide... 7 General Purpose Relays... 7 RVH Series mm Interface Relays... 7 RJ Series Slim Power Relays... 7 RQ Series PCB Relays... 7 RH Series Compact Power Relays... 77

More information

Electronic Circuit Protector ESX10-T

Electronic Circuit Protector ESX10-T Electronic Circuit Protector ESX0-T Description Electronic circuit protector type ESX0-T is designed to ensure selective disconnection of systems. power supplies, which are widely used in industry today,

More information

SX9Z-B SX5L SERIES. LONWORKS Communication Terminals. User s Manual

SX9Z-B SX5L SERIES. LONWORKS Communication Terminals. User s Manual SX9Z-B801-01 SX5L SERIES LONWORKS Communication Terminals User s Manual SAFETY PRECAUTIONS Read this user s manual to make sure of correct operation before starting installation, wiring, operation, maintenance,

More information

Operation Manual. SWF Series Switch Mode Power Supply. SANKEN ELECTRIC CO., LTD No.PAN E-01.

Operation Manual. SWF Series Switch Mode Power Supply. SANKEN ELECTRIC CO., LTD   No.PAN E-01. Operation Manual SWF Series Switch Mode Power Supply 1 Table of Contents Safety Precautions 3 Appearance and Meaning of Safety Warnings 4 Hazard and Caution Safety Warnings 4 Introduction to SWF Series

More information

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01 Monitoring Relays -Phase rue RMS AC/DC Over and nder Current ypes DC0, PC0 DC0 PC0 RMS AC/DC over + under, over+over, under+under current and voltage monitoring relays DC process signal plus/minus monitoring

More information

RT-3 UNIT RELAY 4-POINT TERMINAL

RT-3 UNIT RELAY 4-POINT TERMINAL Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA-N Relay type, PhotoMOS Power (Voltage sensitive type)] -point Terminal [PA-N relay, PhotoMOS Power (Voltage sensitive type)] Mountable

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,

More information

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz 8 Pin Plug Type DIN W48 H48mm 8 Pin Plug Features Upgraded counting speed: 1cps / 3cps / kcps / 5kcps Selectable voltage input (PNP) method or no-voltage input () method Decimal point setting (fixed decimal

More information

Relays & Sockets. Switching & Controls.

Relays & Sockets. Switching & Controls. Switching & Controls For more information on this product family, visit our website. Additional resources include: New and updated product information Downloadable software demos & upgrades Part confi

More information

UNIQUELY DESIGNED RELAY FEATURES

UNIQUELY DESIGNED RELAY FEATURES UL CSA VDE Pending Pending Pending UNIQUELY DESIGNED RELAY K-RELAYS a.8 FEATURES 00 times more reliable than similar designs Extra long life Mechanical: more than 0 8 operations Electrical ( A V): more

More information

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E 1 New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator

More information

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01 Monitoring Relays -Phase rue RMS AC/DC Over and nder Current ypes, PC0 PC0 RMS AC/DC over + under, over+over, under+under current and voltage monitoring relays DC process signal plus/minus monitoring relay

More information

Details on the New G2RS

Details on the New G2RS New G2RS Series The G2RS Space-saving Power Plug-in Relay has a mechanical indicator and nameplate as standard features. A relay with a lockable test button is also available. Details on the New G2RS Overview

More information

20 Series Power Relays

20 Series Power Relays Power Relays 0 Technical Data... Specification... Model Number Structure - Power Relays...3 Model Number Selection... - 7 Accessories... Mounting Clips... Electrical Characteristics... Dimensions... Instructions...3

More information

General Specifications

General Specifications General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter

More information

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions CONTENTS [1] SAFETY PRECAUTIONS: Before use, read the following safety precautions 2 [2] APPLICATION AND FEATURES 5 [3] NAME OF COMPONENT UNITS 6 [4] DESCRIPTION OF FUNCTIONS 8 [5] MEASUREMENT PROCEDURE

More information

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications Latching Relay MMK CSM_MMK_DS_E_1_1 Mechanically Latching Relays Based on the MM Power Relay Low power consumption due to mechanical latch for economic operation. Relays with mixed coil specifications

More information

Sockets. SU Series: DIN Rail Snap-Mount Sockets. F-6 USA: (800) 262-IDEC or (408) , Canada: (888) 317-IDEC ➀➁➄➅ ➁➂➃➄

Sockets. SU Series: DIN Rail Snap-Mount Sockets. F-6  USA: (800) 262-IDEC or (408) , Canada: (888) 317-IDEC ➀➁➄➅ ➁➂➃➄ SU Series: DIN Rail Snap-Mount SU Series: DIN Rail Snap-Mount SUS-L SUS-L -blade DIN-mount/surface mount -blade DIN-mount/surface mount Spring clamp terminals Spring clamp terminals - AWG - AWG 0A A (using

More information

Multi-function 11 pin Plug-in for use with 90 series sockets

Multi-function 11 pin Plug-in for use with 90 series sockets 88 eries - lug-in timers 5-8 A Features 88.02 88.12 Multi-voltage and multi-function timer range Front panel or socket mount 8-11 pin plug-in version available ime scales from 0.05s to 100h 1 delayed contact

More information