1. Main Technical Parameters 1.1 Applicable Caliber: DN15-DN300, other caliber agreement supply. Applicable medium: gas, steam and liquid.
|
|
- Suzanna Patterson
- 5 years ago
- Views:
Transcription
1 VORTEX FLOWMETER
2 Content 1. Main T echnical Parameters 2. Basic Instroduction 3. Meter Wiring 1.1threewire circuit wring 1.2twowire circuit wiring 4. Operation of User Menu 4.1 working screen 4.2 user parameter settings 5. Production and calibration Amplifying panel debugging synopisis diagram Two-wire circuit wiring diagram Three-wire circuit wring diagram Diagram Diagram 1 three-wire system working screen 1 interface Diagram 2 three-wire system working screen 1 interface Diagram 3 working screen 2 deputy-interface Diagram 4 password input initial state Form Form 1 user parameter setting menu Form 2 production calibration menu table 1. Main Technical Parameters 1.1 Applicable Caliber: DN15-DN300, other caliber agreement supply. Applicable medium: gas, steam and liquid. 1.2 Environmental conditions: Ambient temperature: (-30 ~ +70) / (-20 ~ +60 liquid-crystal display). Relative humidity: 5% ~ 90% Atmospheric Pressure: (86 ~ 106) kpa. Medium temperature: (-50 ~ +250), (-50 ~ +350). 1.3 Power Supply a. Three-wire System (1) When using external power supply: 12 ~ 24VDC/30mA (-20% ~ +15%), no output can be as low as 9V (2) When battery-powered (optional): Lithium battery 3.6V (2-13Ah) / 0.3mA. b) Two-wire system 12~24VDC/4-20mA(-20%~+15%)
3 1.4 Output Signal a) Three-wire system (1) Pulse output: High level 8V (power supply voltage 1V). Low Level <0.5V. (2 ) With 1K5 pull-up resistor open collector output (3) RS485 communication: The meter can be configured to RS485 communication interface. Communication range 1200mm. :b) two-wire system (1) Second-line 4 ~ 20mA linear correction electronic current output (When the voltage is 24V, the circuit load 600ohm). (2) No amendment to the original pulse optical isolator output: high 5V (power supply voltage of-1v). (3) Low <0.5V; with 1K5 pull-up resistor open collector output. Extra 12V electronic power need to be supplied. 2. Basic Introduction Designed in three- wire or two-wire system, E Series Display Circuit is a newly emerged compact circuit of Vortex Flow Meter. Its amplified circuit belongs to the Analog type. Within the conventional flow range, the flow rate of gas, liquid and steam can be measured in high accuracy through using this E Series Display Circuit. In addition, switches can be set up to adapt to a variety of medium-calibers and various kinds of measurements. Remote data processing and remote signal circuit are divided into threewire system and two- wire system. The three-wire system can be connected with RS485 communication equipment; it is also batterypowered. Using 4-20mA current output, the two-wire system can provide isolated original pulse output.
4
5
6 3. Meter Wiring 3.2 Two-wire electronic circuit wiring Main power supply and wiring terminal of the output signals two Projected terminals. Connect 24Vdc/30mAdc source in series with load to the following terminals.
7 4. The User Menu Operation 4.1 The Working screen After accessing the electronic source, the meter will first have a self-test, and then enter the main display status of screen 1. The first line: total volume; two decimal display, automatic carry-bit of the decimal point. Units are as same as the non-time part of the instantaneous flow units. The second line: instantaneous flow; retained after the decimal 2, details of flow unit can be seen in the menu settings The third line: frequency value of the flow signals; show F = XXXX.XX Hz. retained after the decimal 2 display The fourth line: the output current value; show I = XX.XX ma, retained after the decimal
8 2 display(only 2W type) VTE3W the lower right corner of the three-wire system is for the battery indicator, batterypowered meter will display the battery power volume. Click "<" button or" + button, there is a switch between working screen 1 and working screen 2 The first line: the temperature setting value; for temperature compensation-related calculations. Show T To retain a decimal display. The second line: pressure set value; for pressure compensation-related calculations. Show P kPa, to retain two decimal places. 3rd line: Enter the state of password being set Press "E" key to enter the initial state of the password input. Press "S" key to cancel input state, returning to the screen 2 vice interface display. Press "+" button in the input state, cyclic changes in cursor values. Click "<" button, move the current input cursor position; In the input state, pressing the "E" key to examine the password. If it is right, enter the menu; IF it is not correct, and then return to the input initial state
9 4.2 User Parameter Setting Press "S" key to exit input state. Press "E" button to confirm the save type. Press "+" key, cyclic changes of the cursor values or symbols. Click "<" key, move the current input cursor to the right one. Enter at most up to 8-bit data (including signs, decimal point). 2, Menu Operation: See the menu browsing Press "+" button to turn in the down direction; click "<" button to turn in the up direction; Press" E "key to enter the submenu. Press "S" key to return to the interface of working screen 2 In the sub-menu, press "S" key to exit; press "E" key to enter the state of modification. If you want to change choice items in the modification state, please press the "+" button down to choose; click "<" button up to choose, press the E button to confirm. If you want to change choice in the input-state, then make the changes according to the input operation. Note: In the parameter setting, the display content can be saved after pressing the "E" button to confirm, or else the set is invalid
10
11 5. Production and Calibration The calibration of instrument production should be done by professionals who have deeper understanding of meters with corresponding calibration equipments. In the second -tier system, the calibration should be done by ammeters which are set with at least a measure range of > 20mA and an accuracy of better than 0.1%. Production calibration and some high-level settings are all carried out in production state. Without relevant equipment and adequate expertise, improper adjustment will result in the working mistakes of the meters. After confirming the password, you can set the state into production, setting the appropriate instrument parameters according to different instrument models. Open the front cover the meter and set the parameters menu according to the definition in Table 2 followed by the need to choose to, and then enter the production calibration menu.
12 Diagram 2 Production calibration menu table Password for the production menu is 11 Amplifying Board Debug Summary Amplification gain and trigger sensitivity employ adjustment with four switches, switch 1/2/3/4 each representing a 1/2/4/8; the sum of the ON number is GB = 1-15 transfer amplifier gain (commonly 4-8) the ratio of the corresponding resistance is 300K / (100K - 4K7), 1_15 magnification is in increases. SB = 1-15 tune the trigger threshold (commonly 4-8) the ratio of corresponding resistance is 300K / (100K - 4K7), 1_15 sensitivity is increased.
13 Test point TP0 is the ground; TP1 (K1, and GB) is adjustable amplified sinusoidal signal, TP2 (K2 and K3) is the top-cut sine wave with band -pass filter of limiting range. TP3 of (SB) is the square-wave which is limited by Schmidt Special trigger backlash. Choosing different calibers and media switches, please see the attached table. Adjust the band K2 and K3 based on actual signal first, and then, if necessary, adjust the amplifier K1 with gain of charge Vortex flow meter amplifier parameter reference table
14 The switch position of the corresponding figures is ON; the switch of the bit number that does not appear is OFF. The above table values are only for reference, and the values should be slightly modulated due to liquid viscosity and gas density in the actual use: it can be transferred to the largecaliber direction for 1-3 gear when the flow frequency is low; it can be transferred to the small-caliber direction for 1-3 gear when the flow frequency is high. Address: CRYOGENIC PROCESS CONTROLS No:1,Tagore street,krishnapuram,ambattur,chennai-53. Ph.No: , Mail.id: Web:
RUNYI GROUP AJ FLOW TOTALIZER. Features
AJ FLOW TOTALIZER Features Suitable for flow (Heat) displaying, calculating and controlling of all kinds of liquids, single or mixed gases and vapor. Input multiple flow sensor signals (Such as VSF, Turbine,
More informationICARUS ELECTRONIC GAS VOLUME CONVERTER
ICARUS ELECTRONIC GAS VOLUME CONVERTER 1. INTRODUCTION 2. TECHNICAL DETAILS ICARUS is an electronic volume converter which, combined with a gas meter, provides the gas measurement in Sm3, calculated at
More informationAmbient Conditions. Operating Conditions. Pressure
Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version
More informationTOSHIBA MACHINE CO., LTD.
User s Manual Product SHAN5 Version 1.12 (V Series Servo Amplifier PC Tool) Model SFV02 July2005 TOSHIBA MACHINE CO., LTD. Introduction This document describes the operation and installation methods of
More informationSLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter
SLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter Overview SLW series Turbine Flow has its simple structure, light weight, high-accuracy, perfect repeatability, sensitivity, easy maintenance and
More informationFLOMID-MX Control unit for electromagnetic flowmeters USERS MANUAL. instrumentación para fluidos. Realitzat: Revisat R+D Electrònic: Aprovat: Data:
instrumentación para fluidos FLOMID-MX Control unit for electromagnetic flowmeters USERS MANUAL Realitzat: Data: Revisat R+D Electrònic: Data: Revisat Of. Comercial: Data: Aprovat: Data: R-MI-Flomid-MX
More informationRHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits
RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English
More information1) What meter do I need in this application?
ELECTRONIC ELECTRONIC Choices 1) What meter do I need in this application? Meter choice is determined by: Level of accuracy required, flowrate, line size, viscosity, fitting type, pressure rating, temperature,
More informationWarranty conditions are available on this website: only in English version
THE MOST ACCURATE BATTERY POWERED SYSTEM FLOWIZ ( M L 2 5 2 ) C O N V E R T E R W I T H B A T T E R Y S U P P L Y Warranty conditions are available on this website: www.isomag.eu only in English version
More informationUser s Manual. F2 Calculator. A metering component for thermal energy applications
User s Manual F2 Calculator A metering component for thermal energy applications Rev 08.24.2007 1 Installation 1.1 At delivery F2 calculators are delivered in the Transport Mode. Only the clock is active
More information7 Function description 7.1 Digital filter Alarm output
User manual KH300 1 Preface 1.1 Preface ---------------------------------------1 1.2 Parts list---------------------------------------2 1.3 Notice------------------------------------------2 2 General 2.1
More information500C Advanced Training Outline
500C Advanced Training Outline 1. Opacity Basics 2. Math used with the 500C 3. Trasmissometer Evolution Single Pass 1. Simple 2. Ambient light interference 3. Difficult to verify calibration Double Pass
More informationOPTISONIC Ultrasonic flowmeter for liquids in all industrial applications
OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature
More informationRUNYI GROUP. Overview. Features SLW. kind ±0.25%R. Output pulse zero drift and. Compact and. Manufacture Standard. Turbine flow meter
SILVER AUTOMATION INSTRUMENTS HTTP://WWW.SILVERINSTRUMENTS.COM RUNYI GROUP SLW Liquid Turbine Flow Meter 1 Overview SLW series Turbine Flow has its simple structure, light weight, high-accuracy, perfect
More informationExperiment P50: Transistor Lab 3 Common-Emitter Amplifier (Power Amplifier, Voltage Sensor)
PASCO scientific Vol. 2 Physics Lab Manual: P50-1 Experiment P50: Transistor Lab 3 Common-Emitter Amplifier (Power Amplifier, Voltage Sensor) Concept Time SW Interface Macintosh file Windows file semiconductors
More informationSonoMeter 31 Energy Meters
SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption
More informationPROCESS & TEMPERATURE CONTROLLERS
PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs
More informationMC133C/133Ci. Electric Power/Energy Calibrator. Operation manual
MC133C/133Ci Electric Power/Energy Calibrator Operation manual MC133C Electric Power/Energy Calibrator Powertek Content 1 Basic information... 5 2 Preparation for operation... 6 2.1 Inspecting package
More informationTECHNICAL NOTES MT-4 Radio Systems TN182 Battery Level Reporting and Remote P25 Test Tone
Battery Level Reporting is a method of activating a repeater remotely to have it transmit a signal that reports the battery voltage level over RF. The Remote P25 Test Tone is a remotely activated Standard
More informationMAGNETIC FIELD METER Operator s Manual
Edition 3.1 2009-09-03 MAGNETIC FIELD METER 2000 Operator s Manual The MFM 2000 is a professional magnetic field instrument To make the best use of the instrument we recommend that you read this manual
More informationSimplified Operations for TM-3100 Series Digital Tachometer
Simplified Operations for TM-3100 Series Digital Tachometer The TM-3100 series Digital Tachometers has the most fundamental function in rotational measurement of four standard models (rotation speed display,
More informationINTRODUCTION CHAPTER 1
TABLE OF CONTENTS Introduction... 3 Package Contents... 5 Design... 7 Key Functions... 9 Grain Species and Measuring Ranges....11 First Steps...13 Measurement...15 Modification...19 Setup...21 Replacing
More informationLmag_W803D Battery Powered Electromagnetic Converter. User Manual
Lmag_W803D Battery Powered Electromagnetic Converter User Manual March, 2016 CONTENT 1 BRIEF...1 2 CONVERTOR PICTURE... 1 3 DISPLAY AND OPERATION...2 3.1 METER MODE... 3 3.2 METER WAKE-UP...4 3.3 SLEEP
More informationFOH201 User manual 1
FOH201 User manual 1 WARNINGS WARNING: HIGH PRESSURE! High pressure gases and liquids are potentially hazardous. Energy stored in these gases or liquids can be released suddenly and with extreme force.
More informationW803C Battery Powered Electromagnetic Converter. User Manual
W803C Battery Powered Electromagnetic Converter User Manual May,2015 INDEX 1 Brief... - 1-2.Converter Picture... - 1-3 Display and Operation...- 2-3.1 Meter Mode... - 3-3.2 Meter Wake-up... - 4-3.3 Sleep
More informationDesign and applications
Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated
More informationThe Transistor Tester user manual
The Transistor Tester user manual Power: The Transistor Tester can be powered from 6.8V-12V DC. This can be achieved by a 9V layerbuilt battery or two 3.7V Lithium-ion battery in series, or with a 9V DC
More informationModel 310H Fast 800V Pulse Generator
KEY FEATURES Temperature Stability +/-5ppm 100 V to 800 V into 50 Ω
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationTeacher s Guide - Activity P51: LR Circuit (Power Output, Voltage Sensor)
Teacher s Guide - Activity P51: LR Circuit (Power Output, Voltage Sensor) Concept DataStudio ScienceWorkshop (Mac) ScienceWorkshop (Win) Circuits P51 LR Circuit.DS (See end of activity) (See end of activity)
More informationOperational Amplifiers
Operational Amplifiers Table of contents 1. Design 1.1. The Differential Amplifier 1.2. Level Shifter 1.3. Power Amplifier 2. Characteristics 3. The Opamp without NFB 4. Linear Amplifiers 4.1. The Non-Inverting
More informationInfocal 9 Energy calculator
Infocal 9 Energy calculator Description/Application MID examination certificate no.: LT-1621-MI004-028 The INFOCAL 9 is an energy calculator, e.g. for combination with or SonoSensor 30. It is especially
More informationElectromagnetic Flowmeter Comet F
Electromagnetic Flowmeter Comet F - Exact measurements - Comfortable calibration with PC - No setup elements - No pressure loss - Periodic cleaning of electrodes - Data backup during power failure - Communication
More informationPLA 33. Power line analyzer. User and service manual. version 2.4
PLA 33 Power line analyzer User and service manual version 2.4 Content. Front control panel and terminal plate...3 7.2.2. System frequency setting...0 2. Device description...4 7.2.3. Password protection...0
More informationCoin vending controller
Coin vending controller Bluetooth For water Vending machine For Model No. ECA4058 Introduction ECA 4058 is a coin vending controller. It is used in water vending machines. We can use JY926 or ICT UCA2
More informationMHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data
Technical documentation Table of content Page 2: Page 3: Page 4: Page 5: Page 6: Page 7: Page 8: Characteristics - applications - technical data Technical data - input quantity - output quantity Electrical
More informationLZYN Triangle Series Mass Flow Meter
LZYN Triangle Series Mass Flow Meter 1. General LZYN Triangle Series Mass Flowmeter is designed according to the Coriolis Principle.It can be widely used for the process detecting and custody transfor/fiscal
More informationINSTALLATION & OPERATION MANUAL
INSTALLATION & OPERATION MANUAL AN25 Totalizer/ Rate Indicator DOC#: MN-AN25.doc Sponsler Co., Inc. AN25 Totalizer/Rate Indicator pg. 2 DOC#: MN-AN25 SPECIFICATIONS Temperature: Operating 0 to 70 C Storage
More informationEfcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK
Efcon Water Installation & User Manual Electro Magnetic Flowmeter (EMF) Page 1 Table of content Page 1.1 General 3 1.2 Application area 4 1.3 Transportation 4 1.4 Principle of Operation 4 1.5 Product Description
More informationVehicle Data Display and Logger Installation and Operation Manual Rev Focus Applied Technologies
Vehicle Data Display and Logger Installation and Operation Manual Rev 1. 1-215 Focus Applied Technologies INTRODUCTION This Vehicle Data Display and Logger is designed as a robust display and logger for
More informationENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake
ENA33LCD Power line analyzer User and service manual version 2.9 (FW version 6.8 and newer) ETI, d.o.o. Obrezija 5 SI-1411 Izlake www.etigroup.eu/products-services 1. Front control panel and terminal plate
More informationInstallation, Operation and Maintenance Manual
M518 Rev. B Model 1030F Indicator-Totalizer Model 1030F Indicator-Totalizer Installation, Operation and Maintenance Manual Table of Contents General... 1 Installation... 1 Operation... 7 Programming...
More informationExperiment P48: Transistor Lab 1 The NPN Transistor as a Digital Switch (Power Amplifier, Voltage Sensor)
PASCO scientific Vol. 2 Physics Lab Manual: P48-1 Experiment P48: Transistor Lab 1 The NPN Transistor as a Digital Switch (Power Amplifier, Voltage Sensor) Concept Time SW Interface Macintosh file Windows
More information8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE
8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE TRANSMILLE LTD. Version 1.1 : Apr 2015 TABLE OF CONTENTS PREPARING FOR CALIBRATION... 4 INTRODUCTION... 4 CALIBRATION INTERVAL SELECTION...
More informationCX105 Conductivity/Resistivity Transmitter
CX105 Conductivity/Resistivity Transmitter User Manual REV A.15 Sensorex Corporation, USA 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. www.sensorex.com IMPORTANT SAFETY INFORMATION Please read and
More informationExperiment P45: LRC Circuit (Power Amplifier, Voltage Sensor)
PASCO scientific Vol. 2 Physics Lab Manual: P45-1 Experiment P45: (Power Amplifier, Voltage Sensor) Concept Time SW Interface Macintosh file Windows file circuits 30 m 700 P45 P45_LRCC.SWS EQUIPMENT NEEDED
More informationGroup: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope.
3.5 Laboratory Procedure / Summary Sheet Group: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope. Set the function generator to produce a 5 V pp 1kHz sinusoidal output.
More informationPage 1/10 Digilent Analog Discovery (DAD) Tutorial 6-Aug-15. Figure 2: DAD pin configuration
Page 1/10 Digilent Analog Discovery (DAD) Tutorial 6-Aug-15 INTRODUCTION The Diligent Analog Discovery (DAD) allows you to design and test both analog and digital circuits. It can produce, measure and
More informationMagnitude and Phase Measurements. Analog Discovery
Magnitude and Phase Measurements Analog Discovery Set up the oscilloscope to measure the signal of the reference voltage (the input voltage from the arbitrary function generator, in this case) and the
More informationRemote Sensor Manual. User Guide. Revision A.0
Remote Sensor Manual User Guide Revision A.0 Contents Remote Sensor User Manual... 3 Connecting Power... 3 Basic Sensor Operation... 4 Basic Sensor Operation with Data Logging... 5 Sensor Calibration Button...
More informationSVM F2 Calculator. A small competent calculator for compact or wall montage. Users manual
SVM F2 Calculator A small competent calculator for compact or wall montage Users manual Users manual F2 1 INSTALLATION... 5 1.1 AT DELIVERY... 5 1.2 CONNECTIONS... 6 2 MOUNTING... 7 2.1 MOUNTING ON A
More information8A. ANALYSIS OF COMPLEX SOUNDS. Amplitude, loudness, and decibels
8A. ANALYSIS OF COMPLEX SOUNDS Amplitude, loudness, and decibels Last week we found that we could synthesize complex sounds with a particular frequency, f, by adding together sine waves from the harmonic
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 - The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement,
More informationM302RM OPERATING MANUAL
M302RM OPERATING MANUAL The Model 302RM is a Linear, high voltage, differential amplifier designed to drive a capacitive load such as Conoptics 350, 360, 370 series E.O. modulators. The amplifier is DC
More informationLaboratory Exercise 6 THE OSCILLOSCOPE
Introduction Laboratory Exercise 6 THE OSCILLOSCOPE The aim of this exercise is to introduce you to the oscilloscope (often just called a scope), the most versatile and ubiquitous laboratory measuring
More informationUsing Circuits, Signals and Instruments
Using Circuits, Signals and Instruments To be ignorant of one s ignorance is the malady of the ignorant. A. B. Alcott (1799-1888) Some knowledge of electrical and electronic technology is essential for
More informationFlow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,
DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration
More informationInstruction Manual. Ultrasonic and Radar
Instruction Manual ABM Gateway Software for 3 & 4 wire Ultrasonic and Radar Instruction Manual Revision 5.8 NOTE: Windows 7 and 8 users are asked to use default screen size (100%). To change from Larger
More informationBATCHMATE 1500 Batch Control Computer Technical Bulletin
TS-5(C) BATCHMATE 5 Batch Control Computer Technical Bulletin DESCRIPTION The BATCHMATE features an 8 digit.55-in. alphanumeric LED display. The pulse input model will accept up to 2, pulses per second
More informationVC835 DIGTAL MULTIMETER Operation Manual
VC835 DIGTAL MULTIMETER Operation Manual CONTENTS GENERAL DESCRIPTION Safety Instructions FEATURES OPERATION MAINTENANCE TROUBLE SHOOTING 1. General Description This is a 3 1/2 digital multimeter with
More informationNX Series Inverters. HVAC Pocket Programming Guide
NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product
More informationUMF. Transmitter for magnetic-inductive flowmeters. Operating Instructions
Transmitter for magnetic-inductive flowmeters UMF Operating Instructions Read these Operating Instructions thoroughly and keep them available for reference Subject to modifications of the dimensions, weights,
More informationSMART TWEEZERS Model ST-1 User s Manual Version 1.0
SMART TWEEZERS Model ST-1 User s Manual Version 1.0 Patent Pending TABLE OF CONTENTS Notice The contents of this document is believed to be accurate, but is not guaranteed by Excelta Corporation. The information
More informationAMT-07. Amplifier for MID-IR PDs, with built-in cooler
AMT-07 OPERATION MANUAL Amplifier for MID-IR PDs, with built-in cooler 1. Application The driver AMT-07 is designed for signal extraction and detection from Mid-IR photodiodes with built-in cooler. 2.
More informationActivity P52: LRC Circuit (Voltage Sensor)
Activity P52: LRC Circuit (Voltage Sensor) Concept DataStudio ScienceWorkshop (Mac) ScienceWorkshop (Win) AC circuits P52 LRC Circuit.DS (See end of activity) (See end of activity) Equipment Needed Qty
More informationRCM DIRECT READING FLOWMETER
RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:
More informationDLVP A OPERATOR S MANUAL
DLVP-50-300-3000A OPERATOR S MANUAL DYNALOAD DIVISION 36 NEWBURGH RD. HACKETTSTOWN, NJ 07840 PHONE (908) 850-5088 FAX (908) 908-0679 TABLE OF CONTENTS INTRODUCTION...3 SPECIFICATIONS...5 MODE SELECTOR
More informationConductivity +/ 2% 1 or 2 point remotely through PLC or directly on board. Any two lead Conductivity probe (K 0.01, K 0.1, K 1.
V 2.0 Revised 1/16/17 Conductivity IXIAN Transmitter Reads Range Accuracy Calibration Supported probes Temp probe Conductivity 0.07µS 100,000µS +/ 2% 1 or 2 point remotely through PLC or directly on board
More informationOPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE
OPERATION & SERVICE MANUAL FOR FC 100 SERIES AC POWER SOURCE FC 110 AC POWER SOURCE VERSION 1.3, April 2001. copyright reserved. DWG No. FC00001 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 1 1.1 GENERAL...
More informationExperiment: P34 Resonance Modes 1 Resonance Modes of a Stretched String (Power Amplifier, Voltage Sensor)
PASCO scientific Vol. 2 Physics Lab Manual: P34-1 Experiment: P34 Resonance Modes 1 Resonance Modes of a Stretched String (Power Amplifier, Voltage Sensor) Concept Time SW Interface Macintosh file Windows
More informationFlow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes
GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - Rotor Characteristics Applications
More informationDB Motorized Impeller
DB928-2430 Motorized Impeller The air mover described in this specification is the DB928-4830. The unit is available a metal impeller blade. The following information includes performance characteristics,
More informationUltrasonic level transmitter Datasheet
Ultrasonic level transmitter Datasheet SUP-DP Supmea ultrasonic level transmitter SUP-DP/SUP-DFG ultrasonic level transmitter Product description The Ultrasonic Level Meter with Chinese and English menu
More informationLABORATORY EXPERIMENT. Infrared Transmitter/Receiver
LABORATORY EXPERIMENT Infrared Transmitter/Receiver (Note to Teaching Assistant: The week before this experiment is performed, place students into groups of two and assign each group a specific frequency
More informationFAST SAMPLING CONVERTER
FAST SAMPLING CONVERTER ML4-F1 HIGH SAMPLING RATE CONVERTER (UP TO 400 SAMPLES/SECOND) Warranty conditions are available on this website: www.isomag.eu only in English version INDEX TECHNICAL DATA... 3
More informationPHASE CUT SIGNAL DRIVERS
FEATURES Input to output isolation 27, 40 or 80 watts output power Fused 24VAC power supply Input and power LED indication DESCRIPTION & OPERATION The Digital Controller Interface Module Phase Cut Driver
More informationGalil Motion Control. DMC 3x01x. Datasheet
Galil Motion Control DMC 3x01x Datasheet 1-916-626-0101 Galil Motion Control 270 Technology Way, Rocklin, CA [Type here] [Type here] (US ONLY) 1-800-377-6329 [Type here] Product Description The DMC-3x01x
More informationTechnical Data Sensor Input Input voltage measuring range (FSO) V 0 ±10 Max. input voltage V <±15 Resolution mv 5 with oversampling 14 Bit mv
Electronics SUNSTAR & 传感与控制 Software http://www.sensor-ic.com/ TEL:0755-83376549 E-MAIL: Remote Control Monitor Type 5825A1 Portable Display Unit for Controlling Transmitters Charge Amplifier The remote
More informationProgrammable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual
T3110 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual Instruction manual for use of T3110 transmitter Transmitter
More informationDB Motorized Impeller
DB628-4818 Motorized Impeller The air mover described in this specification is the DB628-4818. The unit is available with either a metal or plastic impeller blade. In either case the wheel backplate is
More informationDB Motorized Impeller
DB824-4836 Motorized Impeller The air mover described in this specification is the DB824-4836. The unit is available a plastic impeller blade. The following information includes performance characteristics,
More informationINTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]
Feature Suit for LV/ HV voltage system Compact design with all real-time measurement Consist of basic unit and optional modules 10 years back-up of integrated energy data Large LCD, high brightness High
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationSITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview
Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless
More informationDEC-001 Installation Instructions
DEC-001 Installation Instructions Skill Level: The installation of this assembly requires a medium level of expertise in working with modern electronic equipment. The use of appropriate tools, correct
More informationSapphire Instruments Co., Ltd. Calibration Procedure of SI-9101
Sapphire Instruments Co., Ltd. Calibration Procedure of SI-9101 1. How to open the case, please follow the steps. 1.1 Remove the battery lid. 1.2 You will see the two screws and loosen them. Fig. 1 1.3
More informationSVM F22. Calculator for heating or cooling applications. Data sheet
SVM F22 Calculator for heating or cooling applications Data sheet Application area F22 is a flexible calculator designed for measuring and monitoring of small to medium-sized heating or cooling installations.
More informationLAB 8: Activity P52: LRC Circuit
LAB 8: Activity P52: LRC Circuit Equipment: Voltage Sensor 1 Multimeter 1 Patch Cords 2 AC/DC Electronics Lab (100 μf capacitor; 10 Ω resistor; Inductor Coil; Iron core; 5 inch wire lead) The purpose of
More informationBrunata Optuna H. Properties. Counter
Brunata Optuna H Brunata Optuna H measures energy consumption in large and small heating and cooling systems as well as combined heating and cooling systems. The meter is compact and belongs to the first
More informationTechnical description of the fuel tank sensor "Escort TD-500"
Technical description of the fuel tank sensor "Escort TD-500" Kazan, 2016 1 Table of contents 1. General info..3 2. Technical characteristic.. 3 3. Operating mode. 3 3.1. Mode RS-485 3 3.2. Frequency mode
More informationPortable Multi-Channel Recorder Model DAS240-BAT
Data Sheet Portable Multi-Channel Recorder The DAS240-BAT measures parameters commonly found in process applications including voltage, temperature, current, resistance, frequency and pulse. It includes
More informationOPERATION MANUAL OF MODEL TH2681/A HIGH RESISTANCE TESTER
OPERATION MANUAL OF MODEL TH2681/A HIGH RESISTANCE TESTER Changzhou Tonghui Electronic Co., Ltd Addr: No.3 Tianshan Rd., New District, Changzhou Zip: 213022 Tel: 86-519-5132222 Fax: 86-519-59972 Http://
More informationUWYO VR SETUP INSTRUCTIONS
UWYO VR SETUP INSTRUCTIONS Step 1: Power on the computer by pressing the power button on the top right corner of the machine. Step 2: Connect the headset to the top of the link box (located on the front
More informationGTS High Frequency Pulser. Technical Bulletin
GTS High Frequency Pulser Technical Bulletin 02 Elster American Meter High Frequency Pulser System control and data acquisition in gas distribution networks begins with process sensors: sensors to detect
More informationWireless Pulse Transmitter and Receiver System. Ideal for slumpstand wireless metering application
WPTR FEATURES 1-channel wireless pulse transmission. Wireless Pulse Transmitter and Receiver System Ideal for slumpstand wireless metering application Ideal for slumpstands where wiring back to batch room
More informationFLOWPET-EG. Description 1 Accumulated total flow (8-digit) 2 Instantaneous flowrate, L/h (mode:b1) and L/min (mode:b2) Selectable with
GENERAL SPECIFICATION FLOWPET-EG MODEL LS 7 6 7-4 GS.No.GBB323-1-E GENERAL FLOWPET-EG is an OVAL flowmeter primarily intended for use in boiler feed water and fuel oil metering applications. Field proven
More informationLVTX-10 Series Ultrasonic Sensor Installation and Operation Guide
LVTX-10 Series Ultrasonic Sensor Installation and Operation Guide M-5578/0516 M-5578/0516 Section TABLE OF CONTENTS 1 Introduction... 1 2 Quick Guide on Getting Started... 2 Mounting the LVTX-10 Series
More informationModel R2002. Instruction Manual. Infrared Thermometer. reedinstruments www.
Model R2002 Infrared Thermometer Instruction Manual reedinstruments www com Table of Contents Safety... 3 Features... 3 Specifications... 4 Instrument Description... 5 Operating Instructions...6-7 Battery
More informationMastr III P25 Base Station Transmitter Tune-up Procedure
Mastr III P25 Base Station Transmitter Tune-up Procedure 1. Overview The Mastr III Base Station transmitter alignment is performed in several steps. First, the Transmit Synthesizer module is aligned to
More informationCS2010 AND CS2011 ALIGNMENT REFERENCE MANUAL FM HANDHELD TRANCEIVER. Connect Systems Incorporated 1802 Eastman Ave., Suite 116 Ventura CA 93003
CS2010 AND CS2011 ALIGNMENT REFERENCE MANUAL FM HANDHELD TRANCEIVER Connect Systems Incorporated 1802 Eastman Ave., Suite 116 Ventura CA 93003 Version 1.01 Copyright 2009 by Connect Systems Incorporated
More information