1 Remote Sensor Manual User Guide Revision A.0
2 Contents Remote Sensor User Manual... 3 Connecting Power... 3 Basic Sensor Operation... 4 Basic Sensor Operation with Data Logging... 5 Sensor Calibration Button... 6 Sensor Access Website Login... 6 Remote Sensor User Manual 2
3 Remote Sensor User Manual Thank you for purchasing an ABM cellular enabled remote sensor unit. Your sensor will automatically connect to the Sensor Access system updating the system with measurements and downloading any new configuration changes you may have added. This guide will help you understand the operation of your remote sensor unit. Connecting Power Your sensor is designed for low power operations. The sensor requires an input voltage between 6 and 30 volts DC. Connect your power supply directly to the sensor power terminals as illustrated in Figure 1. Do not add any resistors between the sensor and the power supply. Your remote sensor is fully digital and does not provide any loop current signaling. Important Do not use a resistor Load Resistor X250 Ohm 1/4 Watt Input: 6 to 30 VDC Your remote sensor is completely digital. It does not provide a 4mA to 20mA signal. + - Do not add a resistor to power source lines + - ABM Remote Sensor Sensor Housing 6 to 30 VDC connection + - Wiring Terminal Strip Please Note: Power supply wires must be connected to the terminal strip only. Connecting the positive or negative wire to the sensors housing will damage the sensor. Figure 1 Connect your power supply directly to the sensor. Do not use any resistors. Remote Sensor User Manual 3
4 Basic Sensor Operation Your remote sensor is designed to operate from a battery for long period of time. To achieve this goal the sensor spends most of its time in a deep sleep low power mode. Figure 2 shows the basic operation of the sensor from power on to deep sleep mode. To save power the sensor LED will blink green for 1.5 seconds when the sensor is initially powered on. You will notice that the sensor wakes up after a number of minutes, takes a measurement, sends that measurement to the server and then returns to sleep. This cycle is continuously repeated unless you add data logging (see data logging). Power Sensor On Blink LED Green Take Measurement Power Cellular Modem On Connect To 30 Seconds Minimum Send Data Disconnect From Wake Up Exit Low Power Mode Power Down Modem Put Sensor in Deep Sleep Low Power Mode Sleep for a minimum of 2 minutes The sleep time can be changed on the Sensor Access. How long the sensor sleeps between measurements is referred to as Time Between Measurements. Figure 2 Basic sensor operation. Remote Sensor User Manual 4
5 Basic Sensor Operation with Data Logging Your sensor has been designed to operate for long periods off of a battery. The largest power consumption occurs when the cellular modem is powered on and communicating with the Sensor. Using data logging combined with the Time Between Measurements setting (sleep time) you can control how often the cellular modem connects to the Sensor. Your sensor can be configured to log up to 300 measurements before powering on the cellular modem and connecting to the Sensor. This will extend the battery life while still providing frequent measurements. When data logging is enabled the basic sensors operation changes. Each time the sensor wakes up it takes a measurement and logs the data to memory. It must then determine if it should go back to sleep or power up the cellular modem and connect to the server. This is illustrated in Figure 3. Power Sensor On Blink LED Green Take Measurement Save Measurement to Data Log. No User requested more measurements be logged. Connect to server? Yes - User requested measurements Logged. Power Cellular Modem On Connect To 30 Seconds Minimum Send Data Put Sensor in Deep Sleep Low Power Mode Disconnect From Power Down Modem Wake Up Exit Low Power Mode Sleep for a minimum of 2 minutes The sleep time can be changed on the Sensor Access. How long the sensor sleeps between measurements is referred to as Time Between Measurements. Figure 3 Basic sensor operation with data logging enabled. Remote Sensor User Manual 5
6 Sensor Calibration Button Your sensor is equipped with a calibration button that can be used to calibrate the sensor s range. For remote locations the button should be disabled to prevent tampering. To access the calibration button on the sensor remove the sensors lid by unscrewing it. To make calibration changes to the sensor using the button, power must be supplied to the sensor and the button must be pressed for time specified in Table 1. Press the button until the LED turns the desired color and then release the button. Table 1 Calibration Button Button Timing of the Remote Ultrasonic Sensor. Seconds Pressed LED Color Description < 2 Off If the button is pressed for less than 2 seconds it is ignored and no action is taken. > 2 Green Take a measurement and connect to the server now. > 7 Yellow Program the full tank distance equal to the current distance. > 12 Red Program the empty tank distance equal to the current distance. > 17 Off Button pressed for greater than 17 seconds is ignored and no action is taken Where: < means less than and > means greater than. Sensor Access Website Login The measurements from your remote sensor are automatically sent and stored on the Sensor. To view these measurements or change your sensor s settings you need to create and account and login to the Sensor Access Website. The Sensor Access Website login screen is shown in Figure 4. For additional information on how to use the Sensor Access Website download the Sensor Access User Guide (see link at the bottom of the login page) or refer to the online documentation included on each web page. Figure 4 The Sensor Access login page provides access to the Sensor Access system. To access the Sensor Access Website click here. Remote Sensor User Manual 6
Calibration Instruction Manual Emerson 475 Field Communicator. Manual Revision FC.2
Calibration Instruction Manual Emerson 475 Field Communicator Manual Revision FC.2 ABM 2 Wire Radar with HART ABM Sensor Technologies Inc 2013, all rights reserved. Emerson is a registered trademark of
More informationInstruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1
Instruction Manual ABM HART Gateway Software Instruction Manual Revision A.1 Table of Contents Section 1: Getting Started... 3 1.1 Setup Procedure... 3 1.2 Quick Setup Guide for Ultrasonic Sensors... 11
More informationTEK-TROL HART GATEWAY SOFTWARE. Operating Instruction Manual.
TEK-TROL HART GATEWAY SOFTWARE Operating Instruction Manual www.tek-trol.com Table of Contents 1 Getting Started... 2 1.1 Setup Procedure... 2 1.2 Quick Setup Guide for Radar Sensors... 10 2 Level device
More informationInstruction Manual. Ultrasonic and Radar
Instruction Manual ABM Gateway Software for 3 & 4 wire Ultrasonic and Radar Instruction Manual Revision 5.8 NOTE: Windows 7 and 8 users are asked to use default screen size (100%). To change from Larger
More informationDAI. Connecting Analog and Frequency Fuel Level Sensors
DAI. Connecting Analog and Frequency Fuel Level Sensors User Manual www.galileosky.com Contents Necessary Tools, Devices, Materials... 3 General Information... 4 Fuel Level Sensor Connection... 5 Connection
More informationVOLTAGE. User Guide ACCESSORIES. External Sensor DT140. for MicroLog EC600 and EC V ±0.05V ±3% (before calibration)
External Sensor VOLTAGE DT140 Range: Resolution: Accuracy: Input impedance: Calibration: OV protection: 0-10V ±0.05V ±3% (before calibration) 3MΩ 2 calibration points ±30V ACCESSORIES User Guide for MicroLog
More informationBlue Point Engineering
Blue Point Engineering Instruction I www.bpesolutions.com Pointing the Way to Solutions! Puppet - II+ Controller (BPE No. PCA-0001) Servo Position Adjustment EEPROM Digital Button Power 5 Vdc Playback
More informationIntroduction 1. Download socket (the cable plugs in here so that the GENIE microcontroller can talk to the computer)
Introduction 1 Welcome to the magical world of GENIE! The project board is ideal when you want to add intelligence to other design or electronics projects. Simply wire up your inputs and outputs and away
More informationWireless sensor system
Wireless sensor system Internet / Ounet PC in internal network GW Internet connection FIGURE 1 structure of wireless sensor network = Base station = Routing wireless sensor = Wireless sensor General description
More informationSeries and Parallel Circuits Basics 1
1 Name: Symbols for diagrams Directions: 1. Log on to your computer 2. Go to the following website: http://phet.colorado.edu/en/simulation/-construction-kit-dc Click the button that says Play with sims
More informationProLink Radio. 900 MHz SDI-12 Data Radio Scienterra Limited. Version A-0x0C-1-AC 20 October 2009
ProLink Radio 900 MHz SDI-12 Data Radio Scienterra Limited Version A-0x0C-1-AC 20 October 2009 For sales inquiries please contact: ENVCO Environmental Collective 31 Sandringham Rd Kingsland, Auckland 1024
More informationConnecting Mains Electrical Power
Tide Level Monitoring Instrumentation The following documentation details the electrical installation for the tide level monitoring instrumentation and also a summary of the logger configurations required
More informationPatriot Test Station Monitor
LTE Patriot Test Station Monitor Installation Guide Patriot Test Station Monitor Potential Measurement (1) (2) (3) (4) (5) 1 2 3 4 Protected Coupon Reference Cell Pipe NP Coupon The Patriot has a 75V Gas
More informationLT3000 ULTRASONIC LEVEL TRANSMITTER
LT3000 ULTRASONIC LEVEL TRANSMITTER Owner s Manual Specifications Installation Calibration Troubleshooting Warranty Drawings Distributed By: iprocessmart.com 14262 Doolittle Drive San Leandro, CA 94577
More informationCom-Trol ADV-6000 Trouble Shooting Guide Click on red text to go to that page in guide
Com-Trol ADV-6000 Trouble Shooting Guide Click on red text to go to that page in guide Topic Introduction 1 Tool Requirements 1 Trouble Shooting Check List 1 Page(s) Lost communications to controller(s)
More informationQ3.: When switch S is open, the ammeter in the circuit shown in Fig 2 reads 2.0 A. When S is closed, the ammeter reading: (Ans: increases)
Old Exams-Chapter 27 T081 Q1. Fig 1 shows two resistors 3.0 Ω and 1.5 Ω connected in parallel and the combination is connected in series to a 4.0 Ω resistor and a 10 V emf device. The potential difference
More informationMarvelmind Indoor Navigation System Operating Manual V2015_09_21
Marvelmind Indoor Navigation System Operating Manual V2015_09_21 Table of Contents 1) Executive summary...3 2) Basics of the system...4 3) What is in the box...8 4) Technical Specifications...9 Table:
More informationEv3 Robotics Programming 101
Ev3 Robotics Programming 101 1. EV3 main components and use 2. Programming environment overview 3. Connecting your Robot wirelessly via bluetooth 4. Starting and understanding the EV3 programming environment
More informationKey Features. Base-line surveys for planning Construction site monitoring Road traffic noise monitoring
for Sound The connects the Sound to the internet for unattended noise monitoring. It transfers the measurement data to the fully-managed NoiseScout Web Portal in real time or provides a secure access to
More informationpicotalk OPERATING MANUAL V1.2 (May 26, 2010) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: Fax:
picotalk OPERATING MANUAL V1.2 (May 26, 2010) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: 905-803-9274 Fax: 647-439-1470 www.frightideas.com Getting Familiar with your picotalk Mouth Servo Output AUX
More informationUser manual Firmware V1.0-V1.2 HTB230. In-head transmitter
User manual 18.2.2013 Firmware V1.0-V1.2 HTB230 In-head transmitter 1 INTRODUCTION Nokeval HTB230 is a basic level in-head transmitter for RTD sensors. The range and sensor type are programmable using
More informationPhilips Ledalite Phone: Fax: Web: Programming Guide Version 2.0
Philips Ledalite Phone: 604.888.6811 Fax: 800.665.5223 Web: www.ledalite.com Programming Guide Version 2.0 AIRWAVE PROGRAMMING GUIDE 1.0 Linking/Unlinking an Airwave Switch or Photosensor to a Transceiver
More informationExercise 2-2. Four-Wire Transmitter (Optional) EXERCISE OBJECTIVE DISCUSSION OUTLINE. Ultrasonic level transmitter DISCUSSION
Exercise 2-2 Four-Wire Transmitter (Optional) EXERCISE OBJECTIVE Become familiar with HART point-to-point connection of a four-wire transmitter. DISCUSSION OUTLINE The Discussion of this exercise covers
More informationSatellite LED Plus Pro Instructions
Satellite LED Plus Pro Instructions To avoid injury and possible electric shock, it is imperative you: READ AND FOLLOW ALL SAFETY INSTRUCTIONS AND WARNINGS Important Warnings Save these Instructions This
More informationSeries and Parallel DC Circuits
Series and Parallel DC Circuits asic Circuits n electric circuit is closed loop of conductive material (metal wire) that connects several circuit elements together (batteries, resistors, capacitors, etc.)
More informationAC Current Monitor model ACM-2
1.0 Safety Warnings The ACM-2 AC Current Monitor should be installed only by qualified technical personnel with knowledge of industrial electrical wiring and the requirements of the national and local
More informationSeries DL8 Process Data Logger
Series DL8 Process Data Logger Bulletin E-90-DL8 Specifications - Installation and Operating Instructions Input Jack for Interface Cable Security Eyelet Magnetic Strip 2.95 [75] Temperature Sensor 0.656
More informationCURRENT. User Guide ACCESSORIES. External Sensor DT139. for MicroLog EC600 and EC mA ±0.1mA ±3% (before calibration)
External Sensor CURRENT DT139 Range: Resolution: Accuracy: Input impedance: Calibration: OV protection: 0-20mA ±0.1mA ±3% (before calibration) ~170Ω 2 calibration points ±55mA ACCESSORIES User Guide for
More informationPWM regulator for electrolysis cell Η 2
PWM regulator for electrolysis cell Η 2 Ο Red or Gray Battery positive end (+) via fuse 25Α (30Α max) Blue Positive PWM output towards solution 1 Brown Negative PWM output towards solution Solution state
More informationGetting started with your NutriOpt On-site Adviser. Better feed choices today
Getting started with your NutriOpt On-site Adviser Better feed choices today This manual explains how to get started with the NutriOpt On-site Adviser. To make the most of this innovative solution, please
More informationRodni What will yours be?
Rodni What will yours be? version 4 Welcome to Rodni, a modular animatronic animal of your own creation for learning how easy it is to enter the world of software programming and micro controllers. During
More informationIDA 4 XM V 1.X. Installation and configuration of IDA 4 XM User Manual
IDA 4 XM V 1.X Installation and configuration of IDA 4 XM User Manual IMPORTANT SAFETY INSTRUCTIONS - Switch the device s power off before any maintenance operation (changing the CU card, etc.) - The 24V
More informationCCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault
CCE-32 1.09 Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault Index 1. General description... 5 2. Applications... 5 3. Installation... 5 4. Connections...
More informationInstalling a Blade Server
This chapter contains the following sections: in the Chassis, page 1 Server Configuration, page 3 Powering Off a Blade Server Using the Power Button, page 4 Removing a Blade Server from the Chassis, page
More informationDFM Repeater Service Manual A service guide for DFM Repeaters version RPT-5.3
DFM Repeater Service Manual A service guide for DFM Repeaters version RPT-5.3 Revision 1.1 17/08/2016 DFM Software Solutions cc Content The DFM Repeater 1 Probe Setup 2 Repeater Setup 3 Data Routing 4
More informationRS-422/RS-485 Line Tester Model 485T
Not Recommended for New Installations. Please contact Technical Support for more information. RS-422/RS-485 Line Tester Model 485T Documentation Number 485T1995 This product Designed and Manufactured In
More informationET Water SmartWorks Panel Installation Guide
ET Water SmartWorks Panel Installation Guide You are installing a new piece of equipment that retrofits into an existing irrigation controller in order to create a weather-based irrigation control system.
More informationHow Does it Work? PaperCut is an easy to use web based program. It s installed on just one Server or PC, and works on a per user basis.
1 PaperCut Print Management software helps you save money and reduce printer waste in your business, school, college or professional services organisation. Put simply, PaperCut is a software solution that
More informationSTEM in Practice AISWA SAMPLE. with KodeKLIX. Def ine Plan Model Test Ref lect Improve EXTENSION ACTIVITIES
EXTENSION ACTIVITIES STEM in Practice with KodeKLIX Def ine Plan Model Test Ref lect Improve www.ais.wa.edu.au kodeklix.com Peter Crosbie Jan Clarke EXTENSION ACTIVITIES TABLE OF CONTENTS E E EXTENSION
More informationPhysical Inventory System User Manual. Version 19
Physical Inventory System User Manual Version 19 0 Physical Inventory System User Manual 1 Table of Contents 1. Prepare for Physical Inventory... 2. Chapter 1: Starting Inventory... 2.1. CDK/ADP... 3.
More informationTel: (949) Fax: (949) IAA100 Product Manual
IAA100 Product Manual Table of Contents Default Settings... 3 Connections... 3 Standard Span & Zero Adjustment... 4 Shunt Readings... 5 Digitally Controlled Remote Shunt... 5 Switch Configurations... 6
More informationInstalling a Blade Server
This chapter contains the following sections: in the Chassis, page 1 Server Configuration, page 3 Powering Off a Blade Server, page 4 Removing a Blade Server from the Chassis, page 4 Server Troubleshooting,
More informationExercise 2: Source and Sink Current
Digital Logic Fundamentals Tri-State Output Exercise 2: Source and Sink Current EXERCISE OBJECTIVE When you have completed this exercise, you will be able to demonstrate how a tri-state buffer output can
More informationStuduino Icon Programming Environment Guide
Studuino Icon Programming Environment Guide Ver 0.9.6 4/17/2014 This manual introduces the Studuino Software environment. As the Studuino programming environment develops, these instructions may be edited
More informationTRBOnet Mobile. User Guide. for ios. Version 1.8. Internet. US Office Neocom Software Jog Road, Suite 202 Delray Beach, FL 33446, USA
TRBOnet Mobile for ios User Guide Version 1.8 World HQ Neocom Software 8th Line 29, Vasilyevsky Island St. Petersburg, 199004, Russia US Office Neocom Software 15200 Jog Road, Suite 202 Delray Beach, FL
More informationDR-TRC105-EV Evaluation Kit. User s Guide
DR-TRC105-EV Evaluation Kit User s Guide DR-TRC105-304-EV DR-TRC105-315-EV DR-TRC105-345-EV DR-TRC105-372-EV DR-TRC105-390-EV DR-TRC105-403-EV DR-TRC105-434-EV DR-TRC105-450-EV 2010-2015 by Murata Electronics
More informationTop Design Considerations for Low-Power Metering Applications
Top Design Considerations for Low-Power Metering Applications Smart metering brings intelligence and connectivity to energy and resource management Silicon Laboratories Inc., Austin, TX As green energy
More informationEK307 Introduction to the Lab
EK307 Introduction to the Lab Learning to Use the Test Equipment Laboratory Goal: Become familiar with the test equipment in the electronics laboratory (PHO105). Learning Objectives: Voltage source and
More informationUnderstanding the Arduino to LabVIEW Interface
E-122 Design II Understanding the Arduino to LabVIEW Interface Overview The Arduino microcontroller introduced in Design I will be used as a LabVIEW data acquisition (DAQ) device/controller for Experiments
More informationHow to Start Your Own Fundraising Page
How to Start Your Own Fundraising Page T h e G r e e n 5 K. c o m Thank you for supporting the Green 5K! Whether you re participating, volunteering, or want to raise funds for the cause, these instructions
More informationServoDMX OPERATING MANUAL. Check your firmware version. This manual will always refer to the most recent version.
ServoDMX OPERATING MANUAL Check your firmware version. This manual will always refer to the most recent version. WORK IN PROGRESS DO NOT PRINT We ll be adding to this over the next few days www.frightideas.com
More informationLinear Motion Servo Plants: IP01 or IP02. Linear Experiment #0: Integration with WinCon. IP01 and IP02. Student Handout
Linear Motion Servo Plants: IP01 or IP02 Linear Experiment #0: Integration with WinCon IP01 and IP02 Student Handout Table of Contents 1. Objectives...1 2. Prerequisites...1 3. References...1 4. Experimental
More informationAccuSolar SOLAR POWERED SYSTEM
AccuSolar SOLAR POWERED SYSTEM FLO-CORP s AccuSolar Solar Powered Level Monitoring System monitors process conditions through wireless WiFi that communicate up to 1,500 feet to a base station PC. The Solar
More informationUni-Mux XQL Multi-Channel Data Acquisition Module
Uni-Mux XQL Multi-Channel Data Acquisition Module Uni-Mux XQL Multi-Channel Data Acquisition Module * 8 channel differential inputs. * 16 channel single ended inputs. * User programmable via P.C. software.
More informationBlue Point Engineering
Blue Point Engineering Instruction I www.bpesolutions.com Pointing the Way to Solutions! Animatronic Wizard - 3 Board (BPE No. WAC-0030) Version 3.0 2009 Controller Page 1 The Wizard 3 Board will record
More informationAuthor Tutorial for OPTE Editorial Manager System
CONTENTS Registration/Login/Password... 2 Edit Account Information... 5 Track Manuscript Status... 15 Submit Revised Manuscript... 16 View Manuscript Decision... 21 Registration/Login/Password In order
More informationSupply 12Vdc nominal (9 Vdc minimum, 14,5Vdc maximum ) Max Current Drain. from a , V Carrier Frequency
MIX400 48 CHANNELS WIRELESS RECEIVER ON 8 OUTPUTS TECHNICIAN MANUAL ENGLISH DESCRIPTION Mix 400 is a 48 channel universal wireless receiver, memorizable and free assignable on 8 open-collector outputs.
More informationTeleMET II User s Guide. Cellular Interface & Optional Remote Solar Power Pack
TeleMET II User s Guide Cellular Interface & Optional Remote Solar Power Pack Copyright 2016 by RainWise, Inc. All rights reserved. No part of this work may be reproduced in any form except by written
More information9/2/2013 Excellent ID. Operational Manual eskan SADL handheld scanner
9/2/2013 Excellent ID Operational Manual eskan SADL handheld scanner Thank You! We are grateful you chose Excellent ID for your SADL scanner needs. We believe this easy-to-use scanner will provide dependable
More informationTECHNICAL. Time and Temperature Announcer DVA-TNT. Time and Temp Announcer
TECHNICAL Practice TELECOM SOLUTIONS FOR THE 21ST CENTURY DVA-TNT Time and Temp Announcer August 31, 2001 Features Phone...715.386.8861 Time and Temperature Announcer The DVA-TNT Time and Temperature Announcer
More informationUltrasonic Sensor (HART)
Characteristics 500 - LEVEL - DISTANCE - MODULAR - ECONOMIC - Input: - Ranges - Output: - Voltage supply: - Accuracy: - Process connection: - Electrical connection: - Temperature range: - Limit value contacts:
More informationLPU-2127 User Manual
LPU-2127 User Manual Doc #9004169 Rev A1, 04/15 Table of Contents Introduction... iii Warranty and Warranty Restrictions... iv Chapter 1: Specifications and Options... 1 Dimensions...1 Specifications...
More informationJ. La Favre Using Arduino with Raspberry Pi February 7, 2018
As you have already discovered, the Raspberry Pi is a very capable digital device. Nevertheless, it does have some weaknesses. For example, it does not produce a clean pulse width modulation output (unless
More informationProduct Specification for model TT Transducer Tester Rev. B
TT Rev B April 20, 2010 Product Specification for model TT Transducer Tester Rev. B The Rapid Controls model TT Rev B transducer tester connects to multiple types of transducers and displays position and
More informationUnit 4: Principles of Electrical and Electronic Engineering. LO1: Understand fundamental electrical principles Maximum power transfer
Unit 4: Principles of Electrical and Electronic Engineering LO1: Understand fundamental electrical principles Maximum power transfer Instructions and answers for teachers These instructions should accompany
More informationLVTX-10 Series Ultrasonic Sensor Installation and Operation Guide
LVTX-10 Series Ultrasonic Sensor Installation and Operation Guide M-5578/0516 M-5578/0516 Section TABLE OF CONTENTS 1 Introduction... 1 2 Quick Guide on Getting Started... 2 Mounting the LVTX-10 Series
More informationAN Wireless analog data acquisition system with 4-20 ma (current loop) inputs and built-in data logger
Wireless analog data acquisition system with 4-20 ma (current loop) inputs and built-in data logger www.beanair.com Product Video VIDE O OVERVIEW Wireless data logger with 4-20mA current loop inputs (4
More informationExperiment P-10 Ohm's Law
1 Experiment P-10 Ohm's Law Objectives To study the relationship between the voltage applied to a given resistor and the intensity of the current running through it. Modules and Sensors PC + NeuLog application
More informationExercise 3: Ohm s Law Circuit Voltage
Ohm s Law DC Fundamentals Exercise 3: Ohm s Law Circuit Voltage EXERCISE OBJECTIVE When you have completed this exercise, you will be able to determine voltage by using Ohm s law. You will verify your
More informationANI-F-KW1. Multi-Format ANI Encoder For Kenwood Radios. Manual Revision: Covers Software Revisions: ANI-F: 1.
ANI-F-KW1 Multi-Format ANI Encoder For Kenwood Radios Manual Revision: 2009-02-04 Covers Software Revisions: ANI-F: 1.2 and higher This manual & product supports the following radios: Portable: TK-2180/3180
More information500C Advanced Training Outline
500C Advanced Training Outline 1. Opacity Basics 2. Math used with the 500C 3. Trasmissometer Evolution Single Pass 1. Simple 2. Ambient light interference 3. Difficult to verify calibration Double Pass
More informationTRC EV DR TRC EV DR TRC EV
DR-TRC103-EV Evaluation Kit User s Guide DR TRC103 868 EV DR TRC103 915 EV DR TRC103 950 EV DR-TRC103-EV User s Guide (2015/04/17) Page 1 of 11 www.murata.com Introduction The DR TRC103 series evaluation
More informationAIRCRAFTSCALES.COM WIRELESS WEIGHING INSTRUCTIONS.
AIRCRAFTSCALES.COM WIRELESS WEIGHING INSTRUCTIONS. HH2400-3-xxCS Wireless scale system www.aircraftscales.com 561-281-6179 1 INTRODUCTION Thank you for your purchase of our wireless scale system please
More informationVENUE Full Isolation D.I.
VENUE Full Isolation D.I. USER S GUIDE www.lrbaggs.com INTRODUCTION Thank you for purchasing our Venue D.I. This is the first all-discrete acoustic guitar preamp to combine a transformer-coupled D.I. output
More informationRELAY CONTROLLER Spec. Sht.
New Product RELAY CONTROLLER Spec. Sht. ax: (70) 740 263 E-mail: info@abmsensor.com EATURES The ABM Relay Controller provides a simple and low cost means of monitoring radar and ultrasonic level measurement
More informationInterfacing Clockaudio microphones with the Logic Box
Interfacing Clockaudio microphones with the INTRODUCTION One popular application for the is to interface with conferencing microphones that feature mute switches and LED indicators, and Clockaudio is a
More informationCIRCUITS THAT ARE AVAILABLE ON LODAR RECEIVERS Features listed below are available on 92 Series and 93 Series
CIRCUITS THAT ARE AVAILABLE ON LODAR RECEIVERS Features listed below are available on 9 Series and 9 Series STOP CIRCUIT uses are: - OVER TEMPERATURE and OVER PRESSURE, etc. ALLOWS AN EXTERNAL SENSOR TO
More informationTake Control. Introduction. Control Principles
Introduction The XR3000 Configurable Logic Controller (XR3000 Agent) exemplifies a new, more accessible form of automation controller. Its enabling technology allows users to implement and manage their
More informationWireless Pressure Transmitter User Manual Americas
User Manual Americas 900 MHz ISM Band XYR 5000 Line 34-XY-25-01 Rev. 7 User Manual Honeywell Industrial Wireless Pressure Transmitter Models WG51x and WA51x Versions 1.70 or later! Important Information
More informationThank you for purchasing one of our Autotracking devices, this manual will show you how
Last Updated 12/5/2010 Ver 1.3 Thank you for purchasing one of our Autotracking devices, this manual will show you how to use and obtain the most benefit from your device. This manual covers all the installation
More informationMulti-Input Field Unit User Manual
Rev 1.56 June 2004 Multi- Field Unit User Manual A Division of Adaptive Instruments Corp. 577 Main Street Hudson, MA 01749 U.S.A. TEL: 800-879-6576 978-568-0500 FAX: 978-568-9085 Email: support@accutechinstruments.com
More informationA servo is an electric motor that takes in a pulse width modulated signal that controls direction and speed. A servo has three leads:
Project 4: Arduino Servos Part 1 Description: A servo is an electric motor that takes in a pulse width modulated signal that controls direction and speed. A servo has three leads: a. Red: Current b. Black:
More informationAPX Mobile and Portable Automated Test and Alignment
APX Mobile and Portable Automated Test and Alignment Software Updates First things first! Be sure to check that you are running the latest software versions for the 8800SX and its applications. Visit the
More informationWireless Programmer for Wireless Sensor System
R INSTALLATION AND OPERATION INSTRUCTIONS Wireless Programmer for Wireless Sensor System FOR PLATINUM CONTROLS WITH COMMUNICATION Connect to other Wireless units LED Green = in operation Red = charging
More informationGetting started with Search the online area wide prospectus student guide
Getting started with Search the online area wide prospectus student guide Applications for post 16 courses will be made online through the website www.ucasprogress.com know locally as Search and Apply
More informationXLR PRO Radio Frequency (RF) Modem. Getting Started Guide
XLR PRO Radio Frequency (RF) Modem Getting Started Guide XLR PRO Radio Frequency (RF) Modem Getting Started Guide 90002203 Revision Date Description A September 2014 Initial release. B March 2014 Updated
More informationDESCRIPTION NOTE. Power Supply MODEL 2200A PM
Instantly integrate any standard power meter with a pulse output into the LonWorks digital network. The firmware executes on a NeuroLogic Research Model 2200A and provides a low-cost interface to two power
More informationUser manual V1.0 RTB231 RTB232. RTD transmitter
User manual 26.9.2007 V1.0 RTB231 RTB232 RTD transmitter 1 INTRODUCTION RTB231 and RTB232 are basic level DIN rail mounted transmitter for RTD sensors. The range and sensor type are programmable using
More informationMOTOBRIDGE Dispatch Application Overview
MOTOBRIDGE Dispatch Application Overview MOTOBRIDGE IP Interoperable Solution Dispatcher Training July 2009 Starting the Local Dispatch Application Enter the user name and password. Click the OK button.
More informationLab 1: Introduction to Laboratory Equipment ReadMeFirst
Lab 1: Introduction to Laboratory Equipment ReadMeFirst Lab Summary This is the introduction to laboratory equipment and cables. The equipment covered includes the oscilloscope, function generator, power
More informationIMMS-CI-HW. Communications Controller Interface. Installation Instructions IMMS. Controller. Interface. AC From Transformer 24 VAC REM 24 VAC SEN
CI 4 Comm. IMMS-CI-HW Communications Interface POWER From Transformer Ground To REM Installation Instructions To SmartPort Sensor 1 Sensor 2 Sensor 3 From Sensors Sensor Common IMMS Interface From SI or
More informationHANDS-ON LAB INSTRUCTION SHEET MODULE 3 CAPACITORS, TIME CONSTANTS AND TRANSISTOR GAIN
HANDS-ON LAB INSTRUCTION SHEET MODULE 3 CAPACITORS, TIME CONSTANTS AND TRANSISTOR GAIN NOTES: 1) To conserve the life of the Multimeter s 9 volt battery, be sure to turn the meter off if not in use for
More informationAuthor Instructions FPIN Editorial Manager
Author Instructions FPIN Editorial Manager Login Information: www.editorialmanager.com/fpin Your username and password will have been sent to you by the FPIN Project Manager. If you do not have it, please
More informationGS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:
GS series of wireless industrial sensors Strain gauge reader/ transmitter Features: Input: strain gauge Wheatstone bridge: 300ohms to 10kohms. Typical: 1000 ohms. Standard input range: up to 2mV/V full
More informationMK372/Ultrasonic Sensor System. Installation & Setting up Instructions. Comprising. MK372 Indicator/Controller Ultrasonic Transmitter
MK372/Ultrasonic Sensor System Installation & Setting up Instructions Comprising MK372 Indicator/Controller Ultrasonic Transmitter 1 Contents page Page 1.0 Overview 3 2.0 General Specification MK372 4
More informationKirchhoff s laws. Objectives. Assessment. Assessment. Assessment. Assessment 5/27/14. Apply Kirchhoff s first and second laws.
Kirchhoff s laws Objectives Apply Kirchhoff s first and second laws. Calculate the current and voltage for resistor circuits connected in parallel. Calculate the current and voltage for resistor circuits
More information3M Dynatel Far-End Device (FED II) Applications
Testing with the 965DSP and Far-End-Device () The is like having a helper at the far end of the pair while you are performing AUTO tests with the 965DSP. It can qualify new lines or identify service problems
More informationInterface Manual Tank Level Float Stick System
1 Interface Manual Tank Level Float Stick System SignalFire Model: Sentinel-FS-3BIS The SignalFire Sentinel Float Stick Node is an Intrinsically Safe device with the following features: - Standard SignalFire
More informationModel 532 ma/v Loop Calibrator with Loop Diagnostic Operating Instructions
Practical Instrument Electronics Model 532 ma/v Loop Calibrator with Loop Diagnostic Operating Instructions A. Basic Keypad Operations j EZ-Check Switch/EZ-Step Pushbutton Slide the switch to select the
More informationGPS&GPRS TRACKING SYSTEM GT3100
GPS&GPRS TRACKING SYSTEM GT3100 OPERATION/INSTALLER MANUAL REV: 2.0 (GT3100-special, V1.51, GT500-SIM340.C1) I. INTRODUCTION PORTMAN GPS GPRS tracking system GT3100 utilize the GPS tracking function and
More information