Inteligent Digital Transmitter TMD Series

Size: px
Start display at page:

Download "Inteligent Digital Transmitter TMD Series"

Transcription

1 Technical Information TI 024 N/08/en/10.05 Inteligent Digital Transmitter TMD Series Digital transmitter for float type level gauge Introduction The TMD series is a 2-way 2-wire transmitter with built-in microprocessor, used in combination with field level gauges, e.g. LT series. It enables remote calibration of tanks. Information between the transmitter and receiver are selected from variety of input/output modules to meet various specifications. With the module card technology, module can be easily changed, added and combined according to particular requirement. Features Calibration and adjustment for transmission output can be done by HHT (handheld terminal) with a fiber optic cable after the installation of the transmitter (the HHT is also used for other TMD transmitters) TMD series is a compact design and weighs only 10 kgf. Modules for remote transmission output, temperature A/D conversion, level alarm and output for external instruments operation, etc., are available, enabling application to various specifications It can be connected to existing or newly-mounted tank gauges of ours just by installing the modules The main body with EX-protected construction (JIS d 2 G 4 ) is also available and can be used in hazardous areas Specification Level A/D conversion: Optical non-contact absolute encoder Range: 0 ~ mm Accuracy: ±1 mm Power supply: AC100V, 110V, 200V, 220V, ±10% 50/60 Hz

2 Specification (cont.) Power consumption: Approx. 7VA, max, 22VA (2-way 2-wire level transmission) Ambient temperature: -20 ~ +60 C Lightning arrester: Equipped as standard Protection: Weatherproof (IP 55) Flameproof (d 2 G 4 TIIS) - threaded steel conduit type (EEx deiibt6/ ESi) - packing joint type Weight: Approx. 10 kgf Material: Main body, AC4C Body color: Silver (standard) Installation: Mounting on the rear side of tank gauge e.g. LT series (with some adapter installation on other manufacturer s level gauge is possible) TMD transmitter receives liquid level data and all following data, then transmits them to receiver by digital pulse signals (2-wire transmission boards PDC-1 and TRC-1 are necessary. Temperature signals are also available with 4~20 ma) Operation Principle The amount of wire and tape movement of the mechanical level gauge corresponds to liquid level in tanks. The movement is transmitted to measuring drum, which turns the coupling of the level gauge, and is further transmitted to the transmitter. In the transmitter, the level changes transmitted via the TMD TRANSMITTER coupling, gear unit and timing band to the level encode are converted to digital level values. The level values are computed and diagnosed by microprocessor. It processes output alarms and controls temperature element at the same time accordingly. The temperature data are also output with digital or analogue signals. Lower-digitencoder 0~999mm TANK GAUGE GEARUNIT TIMINGBAND Upper-digitencoder 0~89900mm LEVEL A/DI/F BUSLINE HHT MAIN OUTPUT SUB OUTLET INPUT CPU EXTERNAL OUTPUT EXTERNAL OUTPUT EXTERNAL INPUT Fig.1 Input Specification Temperature Input Input element: ADC-1 Used for spot temperature measuring bulb (RCS) TSL - 1A Used for average temperature measuring bulb (RCV) TSL - 1B Used for average temperature measuring bulb for V1 receiver (single element) Range: Cable: Accuracy: Mechanical Duration: Dry contact (TSL-1A): Mercury contact (TSL-1B): ~ C 3-core for spot thermometer per measuring point 2- core + (element number) x 1- core for average thermometer Temperature ± 0.3 C Resolution ± 0.1 C 100 million times 500 million times PT 100Ω (measuring elements with equal intervals are switched corresponding to liquid level) 2 Sakura Endress

3 Output Specification 4 ~ 20 ma Data output DAC-1 Signal: DC 4 ~ 20 ma Data: Level of temperature Cable: 2-core Accuracy: Conversion ± 0.3% Rating: 4 ~ 20 ma Load Impedance: Within 600Ω 2-way 2-wire Digital Serial Transmission PDC-1, TRC-1 (pair) Transmission: 2-way 2-wire digital serial Range: Level 0 ~ mm Temperature ~ C Level alarm: 2 points Status signal: 8 points (standard: 4 points) External signal: 8 points for external instrument operation (standard: 4points) Address number: 0 ~ 255 Cable: accuracy: Response speed: Cable requirement: capacitance 2-core Level ± 0 mm Temperature ± 0.0 C Within 180 ms/unit Maximum line resistance 120Ω/ one way, between wires max. 0.3µ F/loop (CPEV ø:1.2, max 6 km) Note: Sakura Endress receiver is used for this transmissionsion DRM 9700 Output DRM-1 Transmission: 1-way 2-wire digital serial Range: Level:0 ~ mm Temperature: ~ C (with level gauge selfdiagnosis function) Cable: 2-core Accuracy: Level ± 0 mm Temperature: ± 0.0 C Cable requirement : Maximum line resistance 60 Ω/one way, capacitance between wires max. 0.4 µ F/loop (CPEV ø1.2, max 4 km CPEV ø1.9: max. 2 km) Alarm Output OUT-2 Operating function: Transistor (photo coupler) contact Range: Level: 0 ~ mm Temperature: ~ C Alarm point: 8 points (level or temperature) * Set points are easily set by handheld terminal Cable: 16-core (8 points) * Common stand-alone and standard wiring configurations allow only 4 points Accuracy: Level or temperature ±0 Rating: Open collector output by photo coupler Collector currency: 30 ma Collector voltage: 250 V between collector and emitter * See fig. 2 for admissible load impedance BCD Parallel Output (collector common) OUT-3 Sakura Code Parallel Output (collector common) OUT-3 BCD Parallel Output (emitter common) OUT-3 Sakura Code Parallel Output (emitter common) OUT-4 Transmission: Digital parallel Data: Level or temperature Range: Level 0 ~ mm Temperature: ~ C Level gauge alarm: Alarm value previously set can also be displayed (level or temperature) Accuracy: Transmission ± 0 Sakura Endress 3

4 Output Specification (cont.) External Instrument Operation Output CNT-2 Signal: Relay contact Operation function: Operation command is given from Sakura Endress receiver to relay and then the relay starts to operate the external instruments. Contact point: 8 points Cable: Contact capacitance: 16-core (8 points) 220V DC/250V AC max. 2A Patented 2-way 2-wire link transmission system 2-way, 2-wire link transmission has been developed by ourselves in the consideration of avoiding incapability of whole loop data collection caused by loosen or severed line connection. This allows almost no data collection failure like serial connection method by employing serial transmission setup in tank yard under several ambient conditions. MPC Series Overflow Sensor RCV Series Average Temperature Measuring Bulb TMD Transmitter Tank Gauge Monitor (DRM9700) SW Oil-Eye Series Oil-Leak Detector LT Tank Gauge AC 100V BBB Pressure gauge 4~20mA output TMD Transmitter MIC SW RCS Series Spot Temperature Measuring Bulb LT Tank Gauge AC 100V 4 Sakura Endress

5 NRM/NRS MDP/Fuels Manager NRM/NRS MDP/Fuels Manager Outline Drawing B A 5 C D NO. NAME Material Piece 1 Coupling ADC6 1 2 Main body AC4C 1 3 Cover ADC4C 1 4 Terminal box ADC Shrouding bolt ADC6 2 6 HHT connection port Sakura Endress 5

6 Specification Code 6 Sakura Endress

7 Product Structure Product Structure TMD-1000 TGM-1000 continued Main output 0 None mA DC 2 Digital, 2 way - 2 wire, (MDP) 3 Digital, BCD parallel 4 Digital, Sakura code parallel 5 Digital, 2 way - 2 wire, (BBB, MIC) 6 Digital, 2 way - 2 wire, (V1) Function A Basic version Protection class 0 Weather proof IP65 1 Flame proof d2g4, TIIS 2 Flame proof d2g4, TIIS with cable gland 3 Flame proof EEx de IIB T6, CENELEC Second output A mA DC with level alarm B mA DC with monitor DRM-9700 C Level alarm with monitor DRM-9700 D mA DC with Level alarm, monitor DRM-9700 E mA DC with Level gauge, operation command 2 points F Monitor DRM-9700 with Level gauge, operation command 2 points 0 None mA DC 2 Level alarm 3 Monitor DRM Level gauge, operation command 2 points 5 Level gauge, operation command 2 points outer equipment operation command 6 points 6 Outer equipment operation command 8 points Y Special version Input A mA DC with 1-point spot temp. Pt100/JPt100 B mA DC with 3-point spot temp. Pt100/JPt100 C mA DC with 10-points average temp. Pt100/JPt100 D mA DC with 10-points spot temp. Pt100/JPt100 E 4-points status contact with 1-point spot temp. Pt100/JPt100 F 4-points status contact with 3-point spot temp. Pt100/JPt100 G 4 points status contact with 10 points average temp. Pt100/JPt100 H 4 points status contact with 10 points spot temp. Pt100/JPt100 J mA DC with 4 points status contact K mA DC with 4 points status contact with 1-point spot temp. Pt100/JPt100 L mA DC with 4 points status contact with 3 points spot temp. Pt100/JPt100 M mA DC with 4 points status contact with 10 points average temp. Pt100/JPt100 N mA DC with 4 points status contact with 10 points spot temp. Pt100/JPt100 0 None mA DC 2 4 points status contact 3 1 point spot temp. Pt100/JPt point spot temp. Pt100/JPt point Average temp. Pt100/JPt pointmulti spot temp. Pt100/JPt100 Y Special version Powe r suppl y 1 Power supply: 100 VAC,50/60Hz 2 Power supply: 110 VAC,50/60Hz 3 Power supply: 200 VAC,50/60Hz 4 Power supply: 220 VAC,50/60Hz 5 Power supply: 60 VAC,50/60Hz 6 Power supply: 115 VAC,50/60Hz 7 Power supply: 127 VAC,50/60Hz 8 Power supply: 230 VAC,50/60Hz A Power supply: 240 VAC,50/60Hz 9 Special version Paint finish 0 Standard (Silver) 9 Special version Cable entry 0 G (PF), A: 1 1/2" B:3/4" C:1" D:1" 1 NPT, A:1 1/2" B: 3/4" C:1" D:1" 8 Ex d cable gland see drawing 9 Special version Communication type A Emitter common B Corrector common 0 None communication 1 One way communication 2 Two way communication (MIC, BBB) 3 Two way communication (MDP) 4 Two way communication (V1) Temperature input 0 None temperature input 1 Pt100, new JIS=IEC, C 2 Pt100, new JIS=IEC, C 3 JPt100, old JIS, C 4 JPt100, old JIS, C 9 Special version Installation 1 Installation with LT gauge 2 Installation with LTC gauge TMD-1000 Sakura Endress 7

8 Handheld Terminal The handheld terminal (HHT) is used as Power supply: 3V x 2 lithium interface machine to the TMD transmitter. Main Function 1) Basic data set for calibration, alarm, temperature. etc. 2) TMD transmitter data display (error status, level, temperature, etc.) Specification Display: Interface: LCD 16 characters x 2 lines 2-way 1-wire optical data link method Weight: batteries (standard continuous operation time: 25 hours) Approx. 430 gram * TMD transmitter receives liquid level data and all following data, then transmits them to a receiver by digital pulse signals. (2 wire transmission boards PCD-1 and TRC-1 are required. Temperature signals are also available with 4 ~ 20 ma) Installation (e.g.) 1 Handheld Terminal 2 Temperature measuring bulb Flexible fitting 191 HAND HELD TERMINAL HHT-2 MODE SFT OFF ON Tumbler switch Free hand fitting Thick steel cable pipe D 4 A 1 0 _ E 5 B 2 F 6 C 3 ESC BS ENT No. Name 1 Instrument main body 2 Transmitter 3 Terminal box (Large) Remarks Endress+Hauser Japan Co.,Ltd. Product Center Yamanashi Mitsukunugi, Sakaigawacho,Fuefukishi, Yamanashi Japan Phone: Fax: Endress+Hauser Systems & Gauging TI 024 N/08/en/10.05 Printed in Japan We reserve the right to change specification without notice.

Sakura Endress RCV-1000/1200. Average Temperature Measuring Element for Tank Gauging System

Sakura Endress RCV-1000/1200. Average Temperature Measuring Element for Tank Gauging System Technical Information TI 002 N/08/en/02.02 Average Temperature Measuring Element for Tank Gauging System RCV-1000/1200 Multi-point average temperature with tank inventory management control Introduction

More information

FW-9000 series MOST COMPACT & MOST LIGHT SUPER INTELLIGENT SERVO GAUGE OUTLINE FEATURES

FW-9000 series MOST COMPACT & MOST LIGHT SUPER INTELLIGENT SERVO GAUGE OUTLINE FEATURES MOST COMPACT & MOST LIGHT FW-9000 series SUPER INTELLIGENT SERVO GAUGE OUTLINE FW-9000 SUPER INTELLIGENT TANK GAUGE has been developed based on the technical and field application know-how obtained through

More information

MODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors

MODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors Position Sensors 2-WIRE POSITION TRANSMITTER (flameproof, rotary motion type) Functions & Features Differential transformer incorporated Light weight and compact design High resolution Zero & Span adjustable

More information

SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION

SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION ISO-400 ISO-900 SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER Model: ODM-36A FEATURES Microprocessor based 4-wire transmitter suitable for field installation. The unit features isolated inputs

More information

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ). ISO-14001 ISO-9001 SPECIFICATION SHEET CP SERIES 2-WIRE TYPE DO TRANSMITTER Models: DCP-20T FEATURES Rigid aluminium enclosure with free angle mounting. Simple operation offers free range setting, auto-calibration,

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Installation guide 971 SmartRadar LTi

Installation guide 971 SmartRadar LTi Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl

More information

PAD - Heavy Duty Differential Pressure Trasmitter

PAD - Heavy Duty Differential Pressure Trasmitter Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:

More information

FW9000NN Series SERVO BALANCE-TYPE LEVEL GAUGE OUTLINE APPLICATIONS FEATURES

FW9000NN Series SERVO BALANCE-TYPE LEVEL GAUGE OUTLINE APPLICATIONS FEATURES FW9000NN Series SERVO BALANCE-TYPE LEVEL GAUGE OUTLINE FW9000NN Series is the successor to the well received and widely used FW-9000 series for its reliability and variety of long term application. Using

More information

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL. PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL www.unitorq.com UT-1000 Electro-Pneumatic Positioners Linear & Rotary Unmatched Stability in Tough Environments. UniTorq s advanced-control electro-pneumatic

More information

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration

More information

Dissolved Oxygen Transmitter

Dissolved Oxygen Transmitter Dissolved Oxygen Transmitter OBM-67H The OBM-67H is a -wire type (4VDC power supply) dissolved oxygen transmitter housed in a robust, die-cast aluminum enclosure suitable for installation out in the field.

More information

Rotary Measuring Technology

Rotary Measuring Technology Our ATEX encoders now also carry approval for Dust Flameproof-enclosure type of construction with approval for Zone 1 and 21 ExII2GEExdIICT6 and ExII2DIP6xT85 C Shaft ø 12 mm One type for every situation:

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Installation guide 854 XTG Level Gauge

Installation guide 854 XTG Level Gauge Installation guide 854 XTG Level Gauge July 2008 Part no. 4416.276 Rev. 5 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com

More information

Rod probe With coaxial tube reference probe

Rod probe With coaxial tube reference probe Capacitive level transmitters GENERAL DESCRIPTION NIVOCAP 2-wire capacitive level transmitters provide an ideal solution for level measurement of conductive or non-conductive liquids. The probe of the

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments Smart Valve Positioner SS2 Linear / Rotary Smart performance with innovative and ever-strong coil drive even under harsh working environments Easy and quick auto-calibration Detecting RA (reverse acting)

More information

DRS390 High stability, flange mounting

DRS390 High stability, flange mounting DRS 390 1 Monocrystalline silicon smart differential pressure transmitter DRS390 High stability, flange mounting Detailed Information Application the flow of gas, vapor and liquid measurement with device

More information

Hydrostatic Level Measurement silometer FMB 672 Z, FMB 677 Z

Hydrostatic Level Measurement silometer FMB 672 Z, FMB 677 Z Technical Information TI 065F/00/en Hydrostatic Level Measurement silometer FMB 672 Z, FMB 677 Z Commutec transmitters for level measurement of liquids, pastes and sludge Certified for use in explosion

More information

Remote Switching Unit nivotester FTL 320

Remote Switching Unit nivotester FTL 320 Technical Information TI 203F/24/ae Remote Switching Unit nivotester For connection to intrinsically safe Liquiphant level limit switches Applications Limit detection of fluids and bulk solids in tanks

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 DOC. NO. : C3200-E04A FM APPROVED Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 APT3200 Smart Pressure Transmitter Standard SST Housing Description of Product The

More information

Proservo NMS 53x series

Proservo NMS 53x series Technical Information Proservo NMS 53x series Intelligent tank gauge with high accuracy performance Liquid level, I/F, Density & Density Profile Application The Proservo NMS 53... series of intelligent

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG GENERAL SPECIFICATION GS.No.GBB323E-5 GENERAL FLOWPET-EG is an OVAL flowmeter primarily intended for use in boiler feed water and fuel oil metering

More information

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable) Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically

More information

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Sarasota CM200 Sarasota HME900 Density Converter Electronics Sarasota CM00 Sarasota HME00 Density Converter Electronics Users of Sarasota density meters or specific gravity analyzers are offered the choice of a HART compatible, field mounted density converter, or

More information

Installation guide 877 FDI Field Display & Interface

Installation guide 877 FDI Field Display & Interface Installation guide 877 FDI Field Display & Interface November 2008 Part no. 4416.264 Rev. 5 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com

More information

1) What meter do I need in this application?

1) What meter do I need in this application? ELECTRONIC ELECTRONIC Choices 1) What meter do I need in this application? Meter choice is determined by: Level of accuracy required, flowrate, line size, viscosity, fitting type, pressure rating, temperature,

More information

ThermoPLUS Smart Temperature Transmitter

ThermoPLUS Smart Temperature Transmitter No. SS2-TT110-0100 ThermoPLUS Smart Temperature Transmitter Model TT61/71 (Integral Sensor type) OVERVIEW The models TT61/71 Smart Transmitter are temperature transmitters for the model TT90 integral temperature

More information

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Installation guide 873 SmartRadar Control Unit & Antenna Unit Installation guide 873 SmartRadar Control Unit & Antenna Unit Rev. 7 January 2006 Part no. 4416.569 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : info@enraf.nl

More information

Brunata Optuna H. Properties. Counter

Brunata Optuna H. Properties. Counter Brunata Optuna H Brunata Optuna H measures energy consumption in large and small heating and cooling systems as well as combined heating and cooling systems. The meter is compact and belongs to the first

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080 Overview The transmitter is available in an IP67/NEMA 4X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1-path or -path) FUS80 (-path) FUE80 (-path) The transmitter FUS080 is always

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display, DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration

More information

Positioner with HART Communication Type 3780

Positioner with HART Communication Type 3780 Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels

More information

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit High performance microflow Coriolis Flowmeter GENERAL SPECIFICATION GS.No. GENERAL Based on the Coriolis technologies accumulated over many years, the OVAL has broadened its current general purpose coriolis

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO. : C3200-E05A Smart Pressure Transmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 Duon System Co.,Ltd. www.autrol.com AUTROL, AUTROL are trade mark of smart transmitter brand series

More information

FLOWPET-EG. Description 1 Accumulated total flow (8-digit) 2 Instantaneous flowrate, L/h (mode:b1) and L/min (mode:b2) Selectable with

FLOWPET-EG. Description 1 Accumulated total flow (8-digit) 2 Instantaneous flowrate, L/h (mode:b1) and L/min (mode:b2) Selectable with GENERAL SPECIFICATION FLOWPET-EG MODEL LS 7 6 7-4 GS.No.GBB323-1-E GENERAL FLOWPET-EG is an OVAL flowmeter primarily intended for use in boiler feed water and fuel oil metering applications. Field proven

More information

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A Doc. No. : C3100-E05A Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement MODEL APT3100 Duon System Co.,Ltd. www.autrol.com Smart Pressure Transmitter APT3100 Standard Description

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGCW Converter for Electromagnetic Flowmeter GENERAL MAGMAX EGCW is the high-performance separate type converter for electromagnetic flowmeters with the compact housing. Improved self-diagnostic functions

More information

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement Technical Information / Operating Instructions TI 281C/07/en/08.02 No. 51506567 SmarTec M Conductivity Measurement Compact conductivity transmitter with inductive sensor and integrated temperature compensation

More information

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL WITH DIAPHRAGM SEAL APT3200L Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate Fuel Autrol America

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Process Automation. Sensors and Systems:  Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Process Automation Accurate Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Flexible Sensors and Systems: www.fafnir.com Reliable FAFNIR Sensors and Systems Reliable,

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

Level Limit Switch nivotester FTL 370, FTL 372

Level Limit Switch nivotester FTL 370, FTL 372 Technical Information TI 98F/00/en Limit Switch nivotester FTL 370, FTL 37 With intrinsically-safe signal circuits for connection to sensors Liquiphant, Nivopuls, Soliphant. Features at a Glance High operational

More information

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter

More information

Electrical Temperature Measurement

Electrical Temperature Measurement Electrical Temperature Measurement Resistance Thermometers Model TR10-B, for Additional Thermowell Applications Machinery, plant and tank construction Energy and power plant technology Chemical industry

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in

More information

Level and Pressure. Product Information. Vibrating level switches

Level and Pressure. Product Information. Vibrating level switches Level and Pressure Product Information Vibrating level switches Contents Contents 1 Product description 1.1 VEGAVIB... 3 1.2 VEGASWING... 3 2 Function and application 2.1 Functional principle... 5 2.2

More information

Technical Information Nivector FTC968, FTC968Z

Technical Information Nivector FTC968, FTC968Z TI0007F/00/EN/7.6 7494 Products Solutions Services Technical Information Nivector FTC968, FTC968Z Capacitance Point level switch for powder and fine-grained bulk solids Application The Nivector is a small-sized

More information

RMA42. Technical Information

RMA42. Technical Information Technical Information RMA42 Process transmitter with control unit Digital process transmitter for mounting on a top-hat rail for monitoring and visualizing analog measured values Application Plant and

More information

Multifunction Pulse-to-Pneumatic Converter

Multifunction Pulse-to-Pneumatic Converter No. SS2-APN100-0100 Multifunction Pulse-to-Pneumatic Converter Model J-APN11 OVERVIEW The Multifunction Pulse-to-Pneumatic Converter receives an up/down pulse signal to drive a 4-phase pulse motor and

More information

DIGITAL PROGRAM CONTROLLER

DIGITAL PROGRAM CONTROLLER KP1000 SERIES DIGITAL PROGRAM CONTROLLER The KP1000 series is a 96x96mm digital program controller with the indicating accuracy of ±0.1%, the control cycle of approximately 0.1 seconds and maximum 19 program

More information

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

MaxxFlow HTC Flow Measurement for Dry Bulk Solids EN MaxxFlow HTC Flow Measurement for Dry Bulk Solids Manufactured by Product Information www.onthelevel.com MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Product Information Use The MaxxFlow HTC was developed

More information

Condumax CLS21 and CLS21D

Condumax CLS21 and CLS21D Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:

More information

Paddle wheel flow controller for On/Off control

Paddle wheel flow controller for On/Off control addle wheel flow controller for On/Off control Type 8032 compact Type 8032 can be combined with... Type 8032 remote Indication, monitoring, transmitting and On/Off control in one device. rogrammable outputs

More information

Level Measurement silometer FMX 570

Level Measurement silometer FMX 570 Technical Information TI 01F/00/en Level Measurement silometer FMX 570 Measurement of liquids and bulk solids Suitable for explosion hazardous areas For use with capacitance and hydrostatic probes The

More information

Installation guide 970 SmartRadar ATi

Installation guide 970 SmartRadar ATi Installation guide 970 SmartRadar ATi July 2008 Part no. 4416.717 Rev. 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com Website

More information

+GF+ SIGNET Temperature Transmitter Instructions

+GF+ SIGNET Temperature Transmitter Instructions GF SIGNET 80- Temperature Transmitter Instructions ENGLISH -80.090- B-/00 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal

More information

Resistance Thermometers Model Series TR7X0, Sheathed Design

Resistance Thermometers Model Series TR7X0, Sheathed Design Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features

More information

MaxxFlow HTC Flow measurement for dry bulk solids

MaxxFlow HTC Flow measurement for dry bulk solids Product Information EN MaxxFlow HTC Flow measurement for dry bulk solids SWR engineering Messtechnik GmbH envea TM a trademark of Environnement S.A Group MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Use The

More information

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS DRS 300 1 Monocrystalline silicon smart differential pressure transmitter DRS300 High stability Detailed Information application the flow of gas, vapor and liquid measurement with device (volume or mass

More information

Manufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information.

Manufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information. EN Manufactured by M-Sens 2 Online-Moisture Meter for Solids Product Information Moisture 13.47 % www.onthelevel.com Using M-Sens 2 is specifically designed for continuous moisture measurement of solids.

More information

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability. Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell Enraf s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It

More information

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0... Electronic Flow Monitor for liquids measuring monitoring analysing KAL-K Range: approx. 4-200 cm/s p max : 100 bar Temperature of medium: -20... +80 C Option: 0... +120 C Process connection: G ¼, G ½,

More information

Cyclops User s Manual

Cyclops User s Manual Cyclops User s Manual Revision 5.x.x March 14, 2017 Contents Background... 1 Interface... 1 Normal Operation... 1 Controller Input Type... 1 Communication... 2 Sensitivity... 3 Operating Modes... 3 Normal...

More information

Temperature measurement TMD 832 head transmitter

Temperature measurement TMD 832 head transmitter Technical information TI 062R/09/en Mat.-Nr. 510 00782 Temperature measurement TMD 832 head transmitter SMART head transmitter with HART protocol for RTD, Thermocouple and mv input signals Applications

More information

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) DATA SHEET FKH...5 The FCX AIII absolute pressure transmitter (Direct mount type) accurately measures absolute pressure and transmits proportional 4 to

More information

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless

More information

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter Field Intelligent Device Series Electromagnetic Flowmeter Converter LF620,LF622 Introduction Combined with a multi-functional converter LF620 (combined type) or LF622 (separate type) equipped with its

More information

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

C4000. inline control. Photometric Converter.  Real-time photometric converter. Factory zero for scattered light sensors C4000 Photometric Converter inline control Real-time photometric converter Factory zero for scattered light sensors Simultaneous operation of up to four inline sensors Process control functions via Remote

More information

SPECIFICATIONS Digital Indicator 1. General

SPECIFICATIONS Digital Indicator 1. General SPECIFICATIS Digital Indicator 1. General The instrument is a digital indicator for the purpose of instrumentation, and suitable for the application in hopper, tank scale, and so on. 2. Specifications

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 Applications Machine building, plant and vessel construction Propulsion

More information

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter

More information

INFOCAL 8 Energy calculator

INFOCAL 8 Energy calculator Data sheet INFOCAL 8 Energy calculator Description/Application MID examination certificate no.: DE-10-MI004-PTB008 The INFOCAL 8 is an energy calculator e.g. for combination with SONO 1500 CT especially

More information

RAY COMPACT ENERGY METER MECHANICAL

RAY COMPACT ENERGY METER MECHANICAL APPLICATION Fully electronic compact heat meter or compact cooling and heat meter with impeller scanning for recording energy and volume data. Highly accurate recording of all billing data in a heating

More information

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z KOBO-pH Transmitter for ph-value Model APM-Z measuring monitoring analysing COMPACT-LINE Measuring range ph -1 to 14 Switchable from ph to ORP Display of ph value, mv/orp (Oxidation Reduction Potential)

More information

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology

More information

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter

More information

Indumax CLS50/CLS50D. Technical Information

Indumax CLS50/CLS50D. Technical Information Technical Information Indumax CLS50/CLS50D Inductive conductivity sensor for standard, hazardous and high-temperature applications, analog or digital with Memosens protocol Application Indumax CLS50/CLS50D

More information

Conductivity measurement SmarTec S CLD 132

Conductivity measurement SmarTec S CLD 132 Technical Information TI 207C/24/ae Conductivity measurement SmarTec S CLD 132 Transmitter for measurement of conductivity and concentration with inductive sensor Areas of application Alkali/acid concentration

More information

General Specifications

General Specifications General Specifications Model CA51/ CA71 HANDY CAL calibrator GS 77W02A01-01-E GENERAL The CA51/CA71 HANDY CAL calibrators are comprehensive generating/measuring instruments for all

More information

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z KOBO-RP Transmitter for ORP Model ARM-Z measuring monitoring analysing COMPACT-LINE Measuring range -1999 to +1999 mv Switchable from ORP to ph ph or mv/orp (Oxidation Reduction Potential) and temperature

More information

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485) Module type High-speed Digital ler SRX SRX General Description The SRX is a module type digital controller with a super high speed sampling of control updating cycle time of ms (0.0 sec). Dual loop control

More information

Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive

Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive Technical Information TI 202C/07/en No. 51500563 Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive Two-wire transmitter for conductive measurement of conductivity and specific resistance

More information

Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK.

Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK. Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK. A Sarasota 2000 Ultrasonic flowmeter, installed at Watchgate water treatment works in Cumbria on the 2.4m

More information

Young Tech Co., Ltd.

Young Tech Co., Ltd. Smart Positioner Electro-Pneumatic Positioner Pneumatic-Pneumatic Positioner Volume Booster Air Filter Regulator Lock Up Valve Snap Acting Relay Solenoid Valve Electro Position Transmitter Young Tech Co.,

More information