Power dissipation. Code No. Size 1C

Size: px
Start display at page:

Download "Power dissipation. Code No. Size 1C"

Transcription

1 General Characteristics Rated Voltage 1000V DC L/R=ms Breaking Capacity 0kA Standards IEC 09- ed 1.0 (010-9), IEC 09- DC 1000V I n [A] Code No. 0 gpv Code No. 1C Code No. 0 PV (gr) Code No. 1C Power dissipation Pre-arcing Joule [I t] (L/R = ms) Operating Joule [I t] (L/R = ms) , , , , , , Weight [g] 80/0 300/1C Packaging [pcs] 3/ A B C D C gpv, PV(gR) 750V, 1000V dimensions 1 Altech Corp. 35 Royal Road Flemington, NJ (fax)

2 gpv, PV(gR) 1000V t-i characteristics Altech Corp. 35 Royal Road Flemington, NJ (fax) 17

3 General Characteristics Rated Voltage 1000V DC L/R=1ms Breaking Capacity 10k A DC Standards IEC 09- ed 1.0 DC 1000V gpv I n [A] gpv Standard indicator Code No. Power dissipation (0,7 x I n ) Power dissipation Pre-arcing Joule [I t] (L/R = 1ms) Operating Joule [I t] (L/R = 1ms) Weight [g] Packaging [pcs] / / / A B C D E F L N ,8 E B F C D L N A 18 Altech Corp. 35 Royal Road Flemington, NJ (fax)

4 NH1 gpv 1000V t-i characteristics NH gpv 1000V t-i characteristics NH3 gpv 1000V t-i characteristics Altech Corp. 35 Royal Road Flemington, NJ (fax) 19

5 General Characteristics Rated Voltage 1100V DC L/R=5ms Breaking Capacity 10kA DC Standards IEC 09- ed 1.0 (010-9), IEC 09- DC 1100V I n [A] Standard indicator (pic.1) gpv PV (gr) Power dissipation Trip indicator - K contact indicator tor - K S 170 screw Standard Trip indica- (0,7xI n ) (pic.) (pic.3) (pic.1) (pic.) P d Power dissipation Pre-arcing Joule [I t] (L/R = 5ms) Operating Joule [I t] (L/R = 5ms) , 15, , XL , 0, , 3, , 35, ,9 3, ,8, XL ,9, * / / / / 7 5, / / / / / / / / 17, / / / / 17, / / / / 5 53, L , 5, , 0, ,8 7, * / / / * / / / * / / / *L/R=ms, 30kA d.c.; special dimensions (see next page) Weight [g] Packaging [pcs] 750 1/ / /10 Dimensions [mm] A B C E G P R M O 1XL ,5 0,5 13, XL ,3 1, 59 1 *XL (350A) / / / 0 / 3L , 17, *3L (50A, 500A, 30A) / / / Picture 1 Picture 7, R Picture 3 B P C G 19 A E 0 Altech Corp. 35 Royal Road Flemington, NJ (fax)

6 Pre-arcing time (s) tv/s A 15A 3A 100A 10A 315A 50A 350A 00A Pre- a rcing tim e (s) tv/s A 500A 30A Prospective current (A) Ip/A gpv, PV(gR) 1100V t-i characteristics Prospective current (A) Ip/A gpv, PV(gR) 1100V t-i characteristics Altech Corp. 35 Royal Road Flemington, NJ (fax) 1

7 E37771 General Characteristics Rated Voltage 1100V DC L/R=ms Breaking Capacity 10kA DC Standards UL 579, UL 8-1 DC 1100V gpv 1XL XL 3L I n [A] Standard indicator (pic.1) gpv S 170 screw contact (pic.) U 170 screw contact (pic.3) Power dissipation (0,7xI n ) P d Power dissipation Pre-arcing Joule [I t] (L/R = ms) Operating Joule [I t] (L/R = ms) , , , , , , , , , Weight [g] Packaging [pcs] 750 1/ / /10 Dimensions [mm] A B C E G P R M O 1XL ,5 0,5 13, XL ,3 1, L , 17, Picture 1 Picture Altech Corp. 35 Royal Road Flemington, NJ (fax)

8 E37771 Picture 3 Pre-arcing time (s) tv/s A 15A 00A 315A 3A 100A 10A 50A 350A 00A Dimensions [mm] A B C D E F G H K I 1XL XL L Time-current characteristics 10 Pre- a rcing tim e (s) tv/s A Prospective current (A) Ip/A Prospective current (A) Ip/A gpv 1100V t-i characteristics Altech Corp. 35 Royal Road Flemington, NJ (fax) 3

9 General Characteristics Rated Voltage Breaking Capacity Standards Accessories DC 1500V 1500V DC L/R=ms 10kA DC IEC 09- ed. 1.0, UL579, UL8-1 PK XL fuse base 1500V E37771 PENDING 1XL XL 3L I n [A] Standard indicator (pic.1) gpv S 170 screw contact (pic.) U 170 screw contact (pic.3) Power dissipation (0,7xI n ) P d Power dissipation Pre-arcing Joule [I t] (L/R = ms) Operating Joule [I t] (L/R = ms) , , , , ,7 3, , , , , Weight [g] Packaging [pcs] 950 1/ / /9 Dimensions [mm] A B C D E F G H J Picture 1XL XL L Picture 1 Picture 3 Altech Corp. 35 Royal Road Flemington, NJ (fax)

10 E37771 PENDING t-i characteristics 1 1,100 1,000 0,900 ta ( C) A1 0 0,91 5 0,88 0,800 0,700 0, ,8 0,81 0,78 0,7 0,71 0,7 0,3 0, C Altech Corp. 35 Royal Road Flemington, NJ (fax) 5

KO4070 Series. MOUNTING The KO4070 series have integral mounting feet that snap onto standard 35mm DIN rail. They cannot be panel mounted.

KO4070 Series. MOUNTING The KO4070 series have integral mounting feet that snap onto standard 35mm DIN rail. They cannot be panel mounted. KO070 Series TERMINALS Box clamp design terminal blocks are used with the KO070 series enclosures. Wire(s) to be terminated are squeezed between the bottom of the clamp and the busbar for reliable, gastight

More information

FM SERIES. Altech Corp. 35 Royal Road Flemington, NJ P F

FM SERIES. Altech Corp. 35 Royal Road Flemington, NJ P F FM SERIES The FM series foot switches are ideal for light or medium duty applications and especially medical applications. The compact, sturdy but small, ABS housing is designed to meet all the different

More information

L-Series. AC or DC Miniature Molded Case Circuit Breakers. UL489 Listed Circuit Breakers UL 489 UL 508

L-Series. AC or DC Miniature Molded Case Circuit Breakers. UL489 Listed Circuit Breakers UL 489 UL 508 UL 489 ANNEX UL 077 UL 077 L-Series AC or DC Miniature Molded Case UL489 Listed Available in AC and DC models DIN Rail Mounted 7.5mm width Thermal Magnetic 40V, 480Y/77V AC, 50/60Hz 5VDC ( pole); 50VDC

More information

Feed-Through & Multi-Connection Spring Clamp

Feed-Through & Multi-Connection Spring Clamp Feed-Through & Multi-Connection Spring Clamp FEED-THROUGH CSC2.5T CSC4T CSC6T These terminal blocks offer a time saving alternative to the popular screw clamp connection. They can be mounted on 3 DIN rails.

More information

UL508 Listed E Short Circuit Withstand Ratings for UM (V-EA) Manual Motor Controller

UL508 Listed E Short Circuit Withstand Ratings for UM (V-EA) Manual Motor Controller UL 89 ANNEX UL 77 UL 77 UM (V-EA) Series UL508 Listed Manual Motor Controllers Suitable as Motor Disconnect DIN Rail Mounted 7.5mm width per pole Thermal Magnetic 0.3- / 80Y/277V AC, 50/Hz ka Short Circuit

More information

Quality Commitment # #

Quality Commitment # # Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of engineering, manufacturing

More information

PROCESS CONTROLLERS. Table of Contents and Type Numbers

PROCESS CONTROLLERS. Table of Contents and Type Numbers Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of engineering, manufacturing

More information

Semiconductor & Special Protection Protistor Square body NH fuse-links Sizes 000 to 3 ar 500 to 700VAC 16 to 1000A

Semiconductor & Special Protection Protistor Square body NH fuse-links Sizes 000 to 3 ar 500 to 700VAC 16 to 1000A s to ar 5 to VAC 6 to A The /V Protistor fuse-links provide maximum flexibility in equipment design and ultimate protection for today's power conversion equipment. These NH style fuse-links are defined

More information

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35 Altech Corporation Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff

More information

PROTECTION AND CONNECTION. Fusegear DIN-type HRC-fuse links, A gg- and am-types

PROTECTION AND CONNECTION. Fusegear DIN-type HRC-fuse links, A gg- and am-types PROTECTION AND CONNECTION Fusegear DIN-type HRC-fuse links, 2...250 A gg- and am-types F U S E G E A R D I N -T Y P E H R C - F U S E L I N K S Table of content 003 Value propositions 004 DIN-type HRC

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses BS884 Fuses 6x27, 2X6x27, 250 VAC Extremely high breaking capacity fuses: protection of power semiconductors as per IEC standard 60269.1 and 4 250 V voltage COMPLYING WITH IEC gr class (s from 50 to 50

More information

400 Va.c., 500 Va.c., 690 V a.c. Rated current I n. 120 ka

400 Va.c., 500 Va.c., 690 V a.c. Rated current I n. 120 ka Low voltage NV/NH knife-blade fuse-links Electrical characteristics Rated voltage U n 00 Va.c., 500 Va.c., 90 V a.c. Rated current I n - 0 A Breaking capacity at 1,1 U n ka Fusing characteristics gg, am,

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies s for Switching Motors Technical data General data Permissible mounting position The contactors are designed for operation on a vertical mounting surface. C and DC operation S3 3RT14 46 For DC operation

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses Main characteristics Recognized 650 to 300VAC / 63 to 2800A. Exceptionally low I 2 T, Watt losses. Non-magnetic construction, highly reliable low voltage. Indicator system. Conformity to UL, CSA investigated,

More information

MINIATURE DIAZED NEOZED CYLINDER Mini fuses in five sizes to 20 Amps. SQUARE BODY Square body fuses for semiconductor

MINIATURE DIAZED NEOZED CYLINDER Mini fuses in five sizes to 20 Amps. SQUARE BODY Square body fuses for semiconductor TABLE OF CONTENTS MINIATURE DIAZED NEOZED CYLINDER Mini fuses in five sizes to 20 Slow Blow Medium Blow Fast Blow Super Fast Blow "Bottle" fuses in five sizes to 200 gl/gg - Slow Blow - Fast Blow Compact

More information

Make terminal assemblies look professional while increasing wiring efficiency and facilitating troubleshooting. Marking systems can be used to mark terminal block tags, wire markers, shrink tubing, labels

More information

D-Fuses - European Standard

D-Fuses - European Standard -Fuses - European Standard Class: F and gg/gl Voltage ratings: 400V AC - V C ratings: Standards: 0.5A to 00A IEC 6069-3-1 IN VE 063 Part 301 IN 49515 / 49360 /49365 and 495 SIBA -Fuse also known as iazed

More information

OVERVIEW MINI / PANEL MOUNT TERMINALS

OVERVIEW MINI / PANEL MOUNT TERMINALS OVERVIEW INTRODUCTION SCREW CLAMP TECHNOLOGY Screw clamp & Spring Clamp Technology versions Extremely Compact wiring solution 15mm Mini Rail Terminals Modular easy snap together Terminals High Temperature

More information

Fuse Links NV/NH gg with Striker Pin Dimensions

Fuse Links NV/NH gg with Striker Pin Dimensions D E I A 9,8 G J H l l Fuse Links Electrical characteristics Rated voltage U n Rated current I n reaking capacity U n Melting characteristic ertified In accordance with Dimensions according to Two versions

More information

Capacitor Switching Contactors

Capacitor Switching Contactors Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..

More information

QRD Preliminary. High Voltage Diode Module 200 Amperes/3300 Volts

QRD Preliminary. High Voltage Diode Module 200 Amperes/3300 Volts QRD3324 Preliminary Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com High Voltage Diode Module 2 Amperes/33 Volts L NUTS (3TYP) F A D F C J 7 8 B E H 1 2 3 4

More information

Fluke 1660 Series Multifunction Installation Testers

Fluke 1660 Series Multifunction Installation Testers TECHNICAL DATA Fluke 1660 Series Multifunction Installation Testers Reduce test time up to 40 % with Auto Test Auto Test does 5 required installation tests in one sequence, including selectable Type A,

More information

Altech Corporation What is a Safety Relay?

Altech Corporation What is a Safety Relay? Altech orporation Since 1984, Altech orporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff

More information

Use RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING

Use RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING Aluminium 1000A 1250A 1600A 2000A 2250A 2500A 3200A 4000A 4500A R 95503111 95503131 95503131 95503141 95513111 95513131 95513131 95513141 95513151 L 95503211 95503231 95503231 95503241 95513211 95513231

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

Universal Marking System Possibilities

Universal Marking System Possibilities Universal Marking System Possibilities Component Marking Terminal Block Marking Wire Marking Cable Marking Signs Name Plates Legend Plates Logo Plates 2 Altech Corp. 35 Royal Road Flemington, NJ 08822-6000

More information

3 - Protection components Circuit-breakers

3 - Protection components Circuit-breakers Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Series P. Applications

Series P. Applications Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any

More information

DFM600FXM18-A000. Fast Recovery Diode Module DFM600FXM18-A000 FEATURES KEY PARAMETERS V RRM. 1800V V F (typ) 2.0V I F (max) 600A I FM (max) 1200A

DFM600FXM18-A000. Fast Recovery Diode Module DFM600FXM18-A000 FEATURES KEY PARAMETERS V RRM. 1800V V F (typ) 2.0V I F (max) 600A I FM (max) 1200A Fast Recovery Diode Module Replaces DS5438-1.4 DS5438-2 April 2010 (LN26762) FEATURES Low Reverse Recovery Charge High Switching Speed Low Forward Volt Drop Isolated AlSiC Base with AlN Substrates Dual

More information

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00

More information

NS..S contactor relays - with spring terminals AC operated

NS..S contactor relays - with spring terminals AC operated NS..S contactor relays - with spring terminals AC operated NSES 1SBC101015F00 Description NS..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed

More information

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13 Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC

More information

Miniature Fuses BEAB. Features and Benefits FUSES SIBA LLC. SIBA Miniature Fuses Sizes:

Miniature Fuses BEAB. Features and Benefits FUSES SIBA LLC. SIBA Miniature Fuses Sizes: Order from: MARYLAND METRC P.O.Box 6 Owings Mills, MD 7 UA phones: (40) 358-330 (800) 638-830 faxes: (40) 358-34 (800) 87-939 How to order: Please preface each BA art. no./part no. with 'R367-' Example

More information

MULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole

MULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole MULTIBLOC 4a.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS Touch protection IP 20 Safe on load connection/disconnection in accordance with IEC 609473 The production

More information

Protection components

Protection components Multifunction protection relays LT-P Environment Conforming to standards IEC 947-4-1, IEC 34-11, IEC 755, VDE 010, VDE 00. &Ãmarking Meets the essential requirements of the Low Voltage equipment (LV) &

More information

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors

More information

7P Series - Surge Protection Device (SPD) Features 7P P P

7P Series - Surge Protection Device (SPD) Features 7P P P Features 7P.09.1.255.0100 7P.01.8.260.1025 7P.02.8.260.1025 SPD Type 1+2 Surge arrester range - single phase system / three phase system Surge arresters suitable in low-voltage applications in order to

More information

Page 13-2 Page Page 13-7

Page 13-2 Page Page 13-7 Page -2 Page -6 MINIATURE CIRCUIT BREAKERS UP TO 63A 1P, 1P+N, 2P, 3P and 4P versions IEC rated current In: 1-63A IEC short-circuit capacity Icn: 10kA (6kA for 1P+N) Trip characteristic curve: Type B,

More information

Miniature Fuses. SIBA Miniature Fuses Sizes: Voltage ratings. Operation class: Features and Benefits

Miniature Fuses. SIBA Miniature Fuses Sizes: Voltage ratings. Operation class: Features and Benefits Miniature Fuses BA Miniature Fuses izes: Cylindrical fuses: 5x0 6.3x3 5x5 5x30 8x40 8x50 8x85 0x85 8x0 8x50 Axial leads: 5 x 0 6.3 x 3 pin fuses K, Ø 8.4 mm MD fuses: 040 0603 0805 06.6x6. 4.5x8 4.5x6

More information

Eurotest 61557, Instaltest 61557

Eurotest 61557, Instaltest 61557 , Instaltest 61557, Instaltest 61557 Ultimate Instruments for Complete Testing of Electrical Installations Testing Measuring Analysing Recording No. 118740 VDE 0100 BS 7671 CEI 64.8 HD 384 EN 61557 VDE

More information

DATA SHEET Selectable AC transducer TAS-311DG

DATA SHEET Selectable AC transducer TAS-311DG DATA SHEET Selectable AC transducer Measuring on AC networks Class 0.5 (IEC688) measurement Supply/measur. voltage up to 690 V Easy configuration via PC interface possible DEIF A/S Frisenborgvej 33 DK-7800

More information

OVERVIEW INTRODUCTION

OVERVIEW INTRODUCTION OVERVIEW INTRODUCTION SCREW CLAMP CONNECTION TECHNOLOGY Maximum wiring efficiency and reliability Supplied with open clamps ready to accept wires No wire preparation necessary (with/ without ferrule) Vibration

More information

Datasheet. Electronic Circuit Protection ESX10-T

Datasheet. Electronic Circuit Protection ESX10-T Datasheet Electronic Circuit Protection ESX0-T selected in fixed values from 0.5 A...2 A. Failure and status indication are provided by a multicolour LED and an integral short-circuit-proof status output

More information

ENERALE. Electronic Products

ENERALE. Electronic Products CG ATALOGO ENERAL CGATALOGUE ENERALE Electronic Products 106 USE OF POWER SUPPLY UNITS SERIES CS, CL, AR GENERAL NOTES LENGTH OF CONDUCTOR PEELING: 9 mm, model with fixed terminals; 6 mm, model with pluggable

More information

Details on the New G2RS

Details on the New G2RS New G2RS Series The G2RS Space-saving Power Plug-in Relay has a mechanical indicator and nameplate as standard features. A relay with a lockable test button is also available. Details on the New G2RS Overview

More information

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching

More information

568-0x0x-xxx. 3mm LED CBI Circuit Board Indicator Quad-Level x 0 x - x x x

568-0x0x-xxx. 3mm LED CBI Circuit Board Indicator Quad-Level x 0 x - x x x 3mm LED CBI Circuit Board Indicator Quad-Level 568-0x0x-xxx 4.32 [.170] LED 2 LED 3 LED 4 0.51 [.020] LED 1 5.08 [.200] 5.08 [.200] 2,54 5.08 [.200] CATHODE ID 3,81 [.150] 10.54 [.415] 2,79 [.110] 1.91

More information

6mm Interface Relays RV8 Series

6mm Interface Relays RV8 Series 6mm Interface Relays RV8 Series PRODUCT DESCRIPTION Electromechanical C1D2 (screw terminal) Solid State (spring clamp) IDEC 6mm interface relays provide a compact solution for general purpose relay requirements.

More information

Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B

Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B AC switching Solid State Relay Switching through back to back thyristors Long

More information

REX12 Electronic Circuit Protector

REX12 Electronic Circuit Protector Description The compact and flexible all-in-one solution REX consists of several perfectly matched components. It comprises the EM12-T supply module for the plus and minus potential via a single or double

More information

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI General-purpose Relay CSM_GR-_-S_DS_E Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped

More information

CS-10S User Manual. Coin Counter

CS-10S User Manual. Coin Counter Coin Counter CS-10S User Manual Contents 1. General Information...1 2. Diagram... 1 3. Technical specification...2 4. Panel...3 5. Operation...4 5.1 General counting mode...4 5.2 Accumulative counting

More information

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions Installation and start up instructions TAS-311DG Selectable AC transducer Voltage, current, frequency or phase angle transducer Supply voltage up to 690V DEIF A/S Configuration via PC-interface possible

More information

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors. Compact Contactors The CWC compact contactors are offered as a complete solution for switching and controlling motors. Main Features Contactors with screw s for C-3 operation up to Contactors with spring

More information

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6 Index Index Page Capacitor Switching - 2 Contactors Typical Circuit Diagram 2 Auxiliary Contact Blocks 2 Contactors 3 Dimensions 3 Technical Data 4,5,6 Contactor operation 7 Function 8 Construction 9 Oscillogram

More information

DFM1200FXM12-A000. Fast Recovery Diode Module. 1200V V F (typ) 1.9V I F (max) 1200A I FM (max) 2400A V RRM FEATURES APPLICATIONS ORDERING INFORMATION

DFM1200FXM12-A000. Fast Recovery Diode Module. 1200V V F (typ) 1.9V I F (max) 1200A I FM (max) 2400A V RRM FEATURES APPLICATIONS ORDERING INFORMATION Fast Recovery Diode Module DS5480-1.3 November 2007 (LN25323) FEATURES Low Reverse Recovery Charge High Switching Speed Low Forward Voltage Drop Isolated Copper Base plate AlSiC Baseplate With AIN Substrates

More information

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole MULTIBLOC 00.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 00.ST8 comprises NH fuse switch disconnectors for 160A. They are designed for bottom

More information

8.3. Terminal Blocks, Fuse Blocks and Fuse Holders. Contents Description. CHDB Series Power Distribution Blocks. Power Distribution

8.3. Terminal Blocks, Fuse Blocks and Fuse Holders.  Contents Description. CHDB Series Power Distribution Blocks. Power Distribution Terminal Blocks, Fuse Blocks and Fuse Holders.3 CHDB Series Blocks, Enclosed and Open CHDB Series Blocks Product Description Features and Benefits Eaton s CHDB Series of Blocks was designed for high short

More information

3mm LED CBI Circuit Board Indicator.200 High LED Centerline 551-xx07

3mm LED CBI Circuit Board Indicator.200 High LED Centerline 551-xx07 3mm LED CBI Circuit Board Indicator.200 High LED Centerline 551-xx07 7.11 [.280] 5.08 [.200] 1.09 [.043] 4.32 [.170].508 2.89 [.114] 3.68 [.145] CATHODE Red/Yel Cathode for Bi-color 6.35 [.250] 4.4 [.175]

More information

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings Table of Contents Page Selection Table.... 2 Power Distribution Blocks PDBFS Series....................................3-8

More information

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Add-on modules DX 3 63A for MCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4.

More information

Solid State Relay, 1-phase

Solid State Relay, 1-phase PMA Prozeß- und Maschinen-Automation GmbH Solid State Relay, 1-phase Short-Circuit Proof, heat sink integrated Main Characteristics: Standards / Approvals: CE C-Ti I Zero-point switching Short-circuit

More information

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)

More information

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts) IDEC RJ22 Series Slim Relays (Bifurcated Contacts) Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) High contact

More information

REX12 Electronic Circuit Protector

REX12 Electronic Circuit Protector Description The compact and flexible all-in-one solution REX consists of several perfectly matched components. It comprises the EM12-T supply module for the plus and minus potential via a single or double

More information

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications Circuit Breakers FAZ / FAZ6 Installation Products for Industrial Applications Optimum and powerful protection for every application FAZ up to 15 ka IEC/EN 60947-2 up to 10 ka IEC/EN 60898 up to 10 ka UL

More information

Family 400 meters Rel /04/2007

Family 400 meters Rel /04/2007 COMBI49 COMBI420 ISO40 SPEED48 Pag - 6. MAIN FEATURES OF FAMILY 400 METERS Help on line (available on each function) to support the user while connecting the instrument to the installation under measurement

More information

Insulation Test System

Insulation Test System Component Tests Insulation Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 3 Generator Specifications.................

More information

Model NV-ER1808i TBus Eight Port Receiver Hub

Model NV-ER1808i TBus Eight Port Receiver Hub FRONT BACK Features: Transmit 10/100 BaseT Full Duplex Ethernet up to 8,000ft over RG-59/U, 2,000ft over 2-wire/UTP or 1,300ft over Shielded Twisted Pair* The TBus architecture allows multipoint operation

More information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.

More information

Industrial, 2-Pole ZS Type RA2A

Industrial, 2-Pole ZS Type RA2A Solid State Relays Industrial, 2-Pole ZS Type 2-Pole AC Solid State Relay Zero switching For resistive and inductive AC loads Direct copper bonding (DCB) technology LED indication Rated operational current:

More information

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

Type: DILEM 10(220V50HZ,240V60HZ) Article No.: Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230

More information

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-

More information

Insulation Test System

Insulation Test System Component Tests Insulation Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 3 Generator Specifications.................

More information

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description Type: EASY719 DA RC Article.: 274117 Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Related Products SDP Series SFL Series SCP Series SCL Series SDU UPS

Related Products SDP Series SFL Series SCP Series SCL Series SDU UPS 4 Power Supplies SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility

More information

CP-T range Benefits and advantages

CP-T range Benefits and advantages Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers

More information

Type: DILEM 10 G(24VDC) Article No.:

Type: DILEM 10 G(24VDC) Article No.: Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220

More information

Model NV-ER1808i TBus Eight Port Receiver Hub FRONT

Model NV-ER1808i TBus Eight Port Receiver Hub FRONT FRONT BACK Features: Transmit 10/100 BaseT Full Duplex Ethernet up to 8,000ft over RG-59/U, 2,000ft over 2-wire/UTP or 1,300ft over Shielded Twisted Pair* The TBus architecture allows multipoint operation

More information

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads Fluke 345 Power Quality Clamp Meter Technical Data The ideal meter for commissioning and troubleshooting modern electrical loads With a bright color display to analyze the harmonic spectrum, a low-pass

More information

(1,5 modules per pole)

(1,5 modules per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 25kA 80A to 125A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable

More information

Electronic Circuit Protector ESX10-T

Electronic Circuit Protector ESX10-T Electronic Circuit Protector ESX0-T Description Electronic circuit protector type ESX0-T is designed to ensure selective disconnection of systems. power supplies, which are widely used in industry today,

More information

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012 Ref: ART-B22-D70, ART-B22-D125, ART-B22-D175 Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and the secondary

More information

P5201 Universal Programmable Transmitters with Galvanic Isolation

P5201 Universal Programmable Transmitters with Galvanic Isolation Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to

More information

Amp Clamp W/True RMS

Amp Clamp W/True RMS 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 61746 600 Amp Clamp W/True RMS Ideal Catalog Number 61746 Manufacturer Ideal Ideal, Clamp Meter, Clamp-Pro, 600 Amp With

More information

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs

More information

Solid State Relays 1-Phase with Integrated Heatsink Soft Start Switching Types RGC1P..K..

Solid State Relays 1-Phase with Integrated Heatsink Soft Start Switching Types RGC1P..K.. Solid State Relays 1Phase with Integrated Heatsink Soft Start Switching Types RGC1P..K.. 1pole AC solid state contactors Soft start switching for short wave infrared heaters Rated operational voltage:

More information

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar Fig. 1. Isolating amplifier RISH Ducer TV 808 in housing S 17 clipped onto a top - hat rail or screw hole mounting brackets pulled out. Features and Benefits Electric Isolation between input, and power

More information

FJB/IFB enclosures Photovoltaic string protection and monitoring enclosures for solar parks from 8 to 32 strings

FJB/IFB enclosures Photovoltaic string protection and monitoring enclosures for solar parks from 8 to 32 strings Enclosed products and solutions FJB/IFB enclosures enclosures for solar parks from 8 to 32 strings new The solution for > High-power photovoltaic installations (large buildings, fields, solar parks ranging

More information

Measuring current transformers of the W, W series

Measuring current transformers of the W, W series Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000

More information

UTTB 2,5. Extract from the online catalog. Order No.:

UTTB 2,5. Extract from the online catalog. Order No.: Extract from the online catalog UTTB 2,5 Order No.: 3044636 Feed-through modular terminal block, Cross section: - 4 mm², AWG: 26-12, Connection type: Screw connection, Width: 5.2 mm, Color: gray, Mounting

More information

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Modular equipment. Presentation, standards. Standard contactors TeSys GC Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on

More information

Power Distribution Blocks with Short-Circuit Current Ratings

Power Distribution Blocks with Short-Circuit Current Ratings Power Distribution Blocks with Short-Circuit Current Ratings General Information: The requirements of the 005 National Electric Code (NEC) and UL508A now require many electrical panels to carry a Short

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Three-phase monitoring relays

Three-phase monitoring relays 2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted

More information

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Industrial Controls. Catalog IC SIRIUS. Answers for industry. Industrial Controls Catalog IC 10 2012 SIRIUS Answers for industry. Contactor Relays Siemens AG 2012 Overview Standards IEC 60947-1, EN 60947-1, IEC 60947--1, EN 60947--1 The 3TH42 and 3TH43 contactor

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

AC 110V SINGLE PHASE COMPRESSOR WIRING DIAGRAM

AC 110V SINGLE PHASE COMPRESSOR WIRING DIAGRAM page 1 / 6 page 2 / 6 ac 110v single phase pdf Unless this is a very valuable motor, sell it for scrap and buy a single phase motor. I'm guessing you're in the US; you have single phase (2 phase if you

More information