8.3. Terminal Blocks, Fuse Blocks and Fuse Holders. Contents Description. CHDB Series Power Distribution Blocks. Power Distribution

Size: px
Start display at page:

Download "8.3. Terminal Blocks, Fuse Blocks and Fuse Holders. Contents Description. CHDB Series Power Distribution Blocks. Power Distribution"

Transcription

1 Terminal Blocks, Fuse Blocks and Fuse Holders.3 CHDB Series Blocks, Enclosed and Open CHDB Series Blocks Product Description Features and Benefits Eaton s CHDB Series of Blocks was designed for high short circuit current rating (SCCR) applications up to 200,000 amperes. They are assembled with the minimum spacing to meet UL 1953 requirements for feeder circuits in UL 50A industrial control panels, and provide significant wiring flexibility. Available in three-pole open style and single-pole enclosed style with a variety of terminal arrangements and current-carrying capability up to 570 amperes. Enclosed Style IP20 finger-safe enclosure 600 Vac or Vdc (UL 1953), 690 Vac or Vdc DIN rail or panel mount Captive termination screws prevent lost screws Single-pole, gang mountable for multi-pole applications Tin plated Al connections suitable for conductors Flammability, UL 94V-0 Contents Description CHDB Series Blocks Product Selection Technical Data and Specifications Dimensions CH160 Series Power Terminal Blocks Power Terminal Block Accessories Open Style 600 Vac or Vdc (UL 1953) Panel mount Three-pole open design for easy wiring Tin-plated Al connections suitable for conductors Flammability, UL 94V-0 Available covers for additional protection (does not meet IP20) Page V7-T-11 V7-T-11 V7-T-121 V7-T-123 V7-T-126 Standards and Certifications UL Listed 1953, Guide QPQS, File E CSA Certified, Class , File (enclosed style) CE Component IEC (enclosed style) IEC 60529, IP20 (fingersafe) under specific wiring conditions (enclosed style) Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA010000E March V7-T-117

2 .3 Terminal Blocks, Fuse Blocks and Fuse Holders Product Selection (Open) (Enclosed) Technical Data and Specifications Note 1 Finger-safe. CHDB Series Blocks Connection Connection Configuration Amperes Style Poles 2/0 # AWG (4) #4 AWG 175 Open 3 2/0 # AWG (6) #4 AWG 175 Open kcmil #4 AWG (6) #4 AWG 310 Open kcmil #4 AWG (12) #4 AWG 310 Open kcmil #4 AWG (6) #2 AWG 310 Open 3 (3) 1/0 AWG 310 Open 3 2/0 # AWG 2/0 # AWG 175 Enclosed kcmil AWG (6) #2 AWG 30 Enclosed kcmil #4 AWG (12) #4 AWG 570 Enclosed 1 1 Power Terminal Block Short-Circuit rrent Ratings (SCCR) with Fuses Maximum Fuse Class and Amperes Terminal Copper J T RK-1 RK-5 LPJ JJS/JJN LPS-RK/LPN-RK FRS-R/FRN-R SCCR (ka) 2/0 # AWG #4 AWG #4 AWG /0 # AWG #4 AWG #4 AWG kcmil #4 AWG #4 # AWG #4 AWG kcmil #4 AWG #4 # AWG #4 AWG kcmil #4 AWG 1/0 AWG #4 AWG /0 # AWG 2/0 # AWG kcmil AWG #2 AWG #2 AWG kcmil #4 # AWG kcmil #4 AWG #4 AWG #4 AWG V7-T-11 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA010000E March

3 Terminal Blocks, Fuse Blocks and Fuse Holders.3 Power Terminal Block Short-Circuit Ratings (SCCR) for UL 50A Applications with Circuit Breakers Description Enclosure Size in Inches (mm) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) rrent Rating Opening per Pole Note 1 This breaker frame is marked current limiting and suitable for use as current limiting per UL 50A SB /0 # # /0 # # /0 # # /0 # # /0 # # /0 # # /0 # # /0 # # /0 # # /0 # #4 40V ( ) 1 ka 1 ka 1 ka 1 ka 1 ka 1 ka 1 ka 1 ka 1 ka Eaton Breaker Available Breaker rrent Ratings EGB125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 0, 90, EGE125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 0, 90, EGS125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 0, 90, EGH125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 0, 90, EGC , 20, 25, 30, 35, 40, 45, 50, 60, 70, 0, 90, EGB125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 0, 90, EGE125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 0, 90, EGS125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 0, 90, EGH125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 0, 90, EGC , 20, 25, 30, 35, 40, 45, 50, 60, 70, 0, 90, 175 2/0 # 2/0 # 1 ka EGB125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 0, 90, 175 2/0 # 2/0 # EGE125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 0, 90, 175 2/0 # 2/0 # EGS125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 0, 90, 175 2/0 # 2/0 # EGH125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 0, 90, 175 2/0 # 2/0 # EGC , 20, 25, 30, 35, 40, 45, 50, 60, 70, 0, 90, # # # # JGE250 70, 90,, 150, JGS250 70, 90,, 150, JGH250 70, 90,, 150, JGC , 90,, 150, Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA010000E March V7-T-119

4 .3 Terminal Blocks, Fuse Blocks and Fuse Holders Power Terminal Block Short-Circuit Ratings (SCCR) for UL 50A Applications with Circuit Breakers, continued Description Enclosure Size in Inches (mm) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) (609.6 x 50.0 x 171.5) rrent Rating Opening per Pole Note 1 This breaker frame is marked current limiting and suitable for use as current limiting per UL 50A SB # # # # # # # # SCCR at 40V ( ) Eaton Breaker Available Breaker rrent Ratings JGE250 70, 90,, 150, JGS250 70, 90,, 150, JGH250 70, 90,, 150, JGC , 90,, 150, JGE250 70, 90,, 150, JGS250 70, 90,, 150, JGH250 70, 90,, 150, JGC , 90,, 150, kmil #3 #2 # LGE , 300, 350, kmil #3 #2 # LGS , 300, 350, kmil #3 #2 # LGH , 300, 350, kmil #3 #2 # LGC , 300, 350, 400 # # # # 30 ka 1 ka 30 ka 1 ka 30 ka 1 ka LGE , 300, 350, 400, LGS , 300, 350, 400, LGH , 300, 350, 400, LGC , 300, 350, 400, V7-T-120 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA010000E March

5 Terminal Blocks, Fuse Blocks and Fuse Holders.3 Dimensions Approximate Dimensions in Inches (mm) 2.13 (54.1) 4.25 (10.0) (94.0) 6.30 (160.0) 2. (73.2) 5.50 (139.7) (4.3) 5.19 (131.) 1.03 (26.2) 4.00 (101.6) 2.92 (74.2) 3.73 (94.7) 3.70 (94.0) 6.30 (160.0) 2.15 (54.6) 5.50 (139.7) 3.55 (90.2) 1.40 (35.6) 3.70 (94.0) 6.30 (160.0) 5.50 (139.7) Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA010000E March V7-T-121

6 .3 Terminal Blocks, Fuse Blocks and Fuse Holders Approximate Dimensions in Inches (mm) 1.54 (39.1) 1.6 (47.2) 3.2 (97.0) 4.66 (11.4) 3.2 (97.0) 4.66 (11.4) 2.7 (72.9) 2.93 (74.4) 4.49 (114.0) 1.40 (35.6) 4.49 (114.0) 1.40 (35.6) V7-T-122 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA010000E March

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings Table of Contents Page Selection Table.... 2 Power Distribution Blocks PDBFS Series....................................3-8

More information

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings Table of Contents Page Selection Table.... 2 Power Distribution Blocks PDBFS Series....................................3-8

More information

onlinecomponents.com

onlinecomponents.com Short-Circuit Current Ratings and Feeder Spacing SCCR Information: Power Distribution Blocks with SCCR and Feeder Spacing The requirements of the National Electric Code (NEC) and UL508A now require many

More information

Power Distribution Blocks with Short-Circuit Current Ratings

Power Distribution Blocks with Short-Circuit Current Ratings Power Distribution Blocks with Short-Circuit Current Ratings General Information: The requirements of the 005 National Electric Code (NEC) and UL508A now require many electrical panels to carry a Short

More information

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays .6 Control Relays and Timers Product Overview Catalog Number Selection D9, D96 and D99 Series Description D9 = Hockey puck D96 = Compact D99 = DIN rail Contents D 9 2 5 A M D 2 Output Voltage 1 = 2 60

More information

Datasheet WPDB Power Distribution Blocks

Datasheet WPDB Power Distribution Blocks Datasheet WPDB Power Distribution Blocks Now you can manage multiple load connections and a wide range of wire sizes with Weidmuller s Power Distribution blocks. By using the best materials and the best

More information

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)

More information

Datasheet WPDB Power Distribution Blocks

Datasheet WPDB Power Distribution Blocks Datasheet WPDB Power Distribution Blocks Now you can manage multiple load connections and a wide range of wire sizes with Weidmuller s Power Distribution blocks. By using the best materials and the best

More information

Distribution Blocks, Power Blocks, Power Terminals

Distribution Blocks, Power Blocks, Power Terminals Distribution Blocks, Power Blocks, Power Terminals Single Pole Distribution Blocks...3-8 Power Solar Blocks...7-8 Two and Four Pole Distibution Blocks...9-13 Power Blocks & Terminals... 14-19 Power Terminals...20-25

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

LF SERIES CLASS R & H/K5 FUSE BLOCKS

LF SERIES CLASS R & H/K5 FUSE BLOCKS 250 V 00 V Specifications Description The Littelfuse Class R and H/K5 blocks offer many benefits such as indication, snap-to-release DIN rail mounting and universal mounting holes. Class H and Class R

More information

UL Listed power distribution blocks

UL Listed power distribution blocks Technical ata 10537 ffective September 2017 Supersedes ugust 2016 atalog number example: P323-3 is a 3-pole P323 Where: The prefix P323 defines the block s lineside characteristics (i.e., one conductor

More information

40.4. Control Relays and Timers. Contents. D3PR/D3PF Series. General Purpose Plug-In Relays. Features. Standards and Certifications

40.4. Control Relays and Timers. Contents. D3PR/D3PF Series. General Purpose Plug-In Relays. Features. Standards and Certifications Control Relays and Timers. D Series Relay Contents Description Page DPR/DPF Series................................ DPR/DPF Series................................ DPR/DPF Series Catalog Number Selection........................

More information

3.4. Control Relays and Timers. Contents Description. D2RR/D2RF Series. General Purpose Plug-In Relays. Features

3.4. Control Relays and Timers. Contents Description. D2RR/D2RF Series. General Purpose Plug-In Relays. Features Control Relays and Timers. D Series Relay Contents Description DRR/DRF Series......................... DRR/DRF Series Catalog Number Selection................ Product Selection....................... Accessories............................

More information

System Components and Accessories

System Components and Accessories OutBack Panel Mount Breakers Panel mounted hydraulic-magnetic type breakers that can be used for DC sources, inverters or load circuits. Model Current Voltage Branch Terminals Width Rating Rating Circuit

More information

Feed-through terminals

Feed-through terminals s Screw connection system RKB 4 BKA 2,5 BKA 4 BKA 0 Rail mount on TS 5 / TS 32 / TS 35 / Direct mounting Connection diagram M 3 M 2,5 M 3 M 4 Connection type Dimension (L x W x H) with TS 5 mm with TS

More information

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink AC Solid State Contactor, 1- and 2 poles Zero switching for heating and motor applications Instant-on switching Rated operational current

More information

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module DATASHEET - DILA-22(24VDC) Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILA-22(24VDC) Catalog No. 276414 Eaton Catalog No. XTRE10B22TD EL-Nummer 4130211 (Norway) Product range DILA

More information

DISTRIBUTION BLOCKS POWER BLOCKS POWER TERMINALS

DISTRIBUTION BLOCKS POWER BLOCKS POWER TERMINALS DISTRIBUTION BLOCKS POWER BLOCKS POWER TERMINALS 3-8 Single Pole Distribution Blocks 7-8 Power Solar Blocks 9-13 Two and Four Pole Distibution Blocks 14-19 Power Blocks & Terminals 20-25 Power Terminals

More information

Data sheet. W-Series WDU 10

Data sheet. W-Series WDU 10 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Data sheet. W-Series WDU 4 BL

Data sheet. W-Series WDU 4 BL The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching

More information

3.4. Control Relays and Timers. Contents Description D5RR/D5RF Series... D7PR/D7PF Series. General Purpose Plug-In Relays

3.4. Control Relays and Timers. Contents Description D5RR/D5RF Series... D7PR/D7PF Series. General Purpose Plug-In Relays .4 D7 Series Relay Contents Description D1RR/D1RF Series......................... D2RR/D2RF Series......................... DRR/DRF Series......................... D4 Series................................

More information

Description Basic devices with positive operation contacts

Description Basic devices with positive operation contacts Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILA-31(24VDC) Articleno. 276379 CatalogNo. XTRE10B31TD Deliveryprogramme Product range DILA relays Application Contactor relays Description Basic devices with

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices

More information

Data sheet. W-Series WDU 2.5

Data sheet. W-Series WDU 2.5 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications Circuit Breakers FAZ / FAZ6 Installation Products for Industrial Applications Optimum and powerful protection for every application FAZ up to 15 ka IEC/EN 60947-2 up to 10 ka IEC/EN 60898 up to 10 ka UL

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)

More information

Specifications. Class R Blocks 250 V FLNR/FLNR_ID KLNR LLNRK TLN. Torque N-m (120 in-lbs) 2/0-6 AWG

Specifications. Class R Blocks 250 V FLNR/FLNR_ID KLNR LLNRK TLN. Torque N-m (120 in-lbs) 2/0-6 AWG LF Series lass H/K5 AND R Fuse Blocks Specifications Voltage : 250 V, 600 V Ampere s: 0 600 A Leakage urrent:

More information

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole MULTIBLOC 00.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 00.ST8 comprises NH fuse switch disconnectors for 160A. They are designed for bottom

More information

Datenblatt. W-Series WDU 10

Datenblatt. W-Series WDU 10 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A The solution for Load break switches > Power distribution. sircm_100_a_1_cat Rotary switch SIRCO M 3 x 100 A Strong points > Total integration. > Wide range of accessories. > Upgradeability. > Compliance

More information

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Modular equipment. Presentation, standards. Standard contactors TeSys GC Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on

More information

Contents XR U 1 D 12 G. Poles 1 = 1PDT 2 = 2PDT. Type D = Standard relay S = Octocoupler (solid-state) H = High current

Contents XR U 1 D 12 G. Poles 1 = 1PDT 2 = 2PDT. Type D = Standard relay S = Octocoupler (solid-state) H = High current Control Relays and Timers Relay Product Overview.2 Contents Description Standard Terminal Block Relays............ OptoCoupler Terminal Block Relays......... High Current Terminal Block Relays.........

More information

Powerpole Connectors - PP120: up to 240 Amps

Powerpole Connectors - PP120: up to 240 Amps Powerpole Connectors - : up to 240 Amps series Powerpole housings are designed to accommodate up to 1/0 ( mm²) wires and handle high currents up to 240 amps. Reducing bushings allow to accept down to #8

More information

MULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole

MULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole MULTIBLOC 4a.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS Touch protection IP 20 Safe on load connection/disconnection in accordance with IEC 609473 The production

More information

Success Depends on the Crimp

Success Depends on the Crimp Success Depends on the Crimp Understanding the UL-486F Standard for Bare and Covered Ferrules Vince Barone, May 12, 2015 1 Agenda 2 What is a Ferrule? Ferrules are terminals that only have a barrel. They

More information

Solid State Relays 1-Phase with Integrated Heatsink Soft Start Switching Types RGC1P..K..

Solid State Relays 1-Phase with Integrated Heatsink Soft Start Switching Types RGC1P..K.. Solid State Relays 1Phase with Integrated Heatsink Soft Start Switching Types RGC1P..K.. 1pole AC solid state contactors Soft start switching for short wave infrared heaters Rated operational voltage:

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I have a 500 KVA generator, with no overcurrent protection

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

Data sheet... W-Series WDU 2.5

Data sheet... W-Series WDU 2.5 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Data sheet. W-Series WDU 2.5 RT

Data sheet. W-Series WDU 2.5 RT The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application

More information

Datasheet. W-series terminal with clamping yoke connection WDU 16

Datasheet. W-series terminal with clamping yoke connection WDU 16 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

BKA 2,5 M 3 M 2,5 M 3 M 4. Feed-through terminal 2 connectors. Screw connection technology. 22 x 5 x 23

BKA 2,5 M 3 M 2,5 M 3 M 4. Feed-through terminal 2 connectors. Screw connection technology. 22 x 5 x 23 s Screw connection system RKB 4 BKA 2,5 BKA 4 BKA 0 Rail mount on TS 5 / TS 32 / TS 35 / Direct mounting Connection diagram M 3 M 2,5 M 3 M 4 Connection type Dimension (L x W x H) with TS 5 mm with TS

More information

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 S10N06P0P KVA 1PH 10/40V 16/3V Buck Boost Transformer Eaton Corp Catalog Manufacturer Description Weight per unit Product

More information

Page 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty.

Page 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty. Page -2 Page - DIRECT-ON-LINE STARTERS Motor ratings up to 9A 0V in IEC AC duty General use up to 6A / motor rating up to 2A 600V per UL/CSA Versions with Start-Stop/Reset buttons or Reset button Versions

More information

Safety switches with slotted hole lever

Safety switches with slotted hole lever Safety switches with slotted hole lever Selection diagram C1 C C C4 C5 Straight slotted hole lever Slotted hole lever at the left Slotted hole lever at the right (without bend) Slotted hole lever at the

More information

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer

More information

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5 Applied Grounding and Bonding Paul Dobrowsky Member NEC Panel 5 1 Introduction This presentation is a representative sample from the following Chapters of Applied Grounding and Bonding. Chapter 1, Introduction

More information

New Products Catalogue 2009 Safety Relays ESR5

New Products Catalogue 2009 Safety Relays ESR5 www.moeller.net New Products Catalogue 2009 Safety Relays ESR5 u Description Functional safety on machines monitoring with safety relays ESR5 Emergency-stop circuits Monitoring of movable guards with guard

More information

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product

More information

RN Thyristor Controllers

RN Thyristor Controllers Data Sheet RN Thyristor Controllers RN Thyristor Controllers Thyristor Controllers (solid state relays) provide a means of varying the voltage for electrically resistive s, typically electric heating elements.they

More information

Ten Port Multi-Band Antenna

Ten Port Multi-Band Antenna DATA SHEET Eight High Broadband ports simultaneously covering PCS, AWS / AWS-3 and WCS bands Eight High Broadband ports with two Low Band ports in one antenna Excellent elevation side-lobe performance

More information

KRPA, KRP, KA, KR series

KRPA, KRP, KA, KR series Catalog 1084 Issued -0 KRPA, KRP, KA, KR series to 10 Amp General Purpose Relay File E944, E, E818 (KR Hermetic) File LR14 KRPA KRP KA Users should thoroughly review the technical data before selecting

More information

P48G11S05P 5KVA 1PH 480V - 120/240V Mini Power Center

P48G11S05P 5KVA 1PH 480V - 120/240V Mini Power Center 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 P48G11S05P 5KVA 1PH 480V - 10/40V Mini Power Center Eaton Corp Catalog Number Manufacturer Description Weight per unit

More information

Sectional Terminal Blocks

Sectional Terminal Blocks General Information: Sectionals are terminal blocks which are made up of individually molded units with electrically conductive members which, when assembled together, make up the block producing the required

More information

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers .5 Transformers Distribution Transformers Three-Phase Type DT-3E Totally Enclosed Non-Ventilated Totally Enclosed Non-Ventilated Transformers Product Description Note: The following pages provide listings

More information

Semiconductor & Special Protection Protistor Square body NH fuse-links Sizes 000 to 3 ar 500 to 700VAC 16 to 1000A

Semiconductor & Special Protection Protistor Square body NH fuse-links Sizes 000 to 3 ar 500 to 700VAC 16 to 1000A s to ar 5 to VAC 6 to A The /V Protistor fuse-links provide maximum flexibility in equipment design and ultimate protection for today's power conversion equipment. These NH style fuse-links are defined

More information

Datenblatt. W-Series WDU 2.5

Datenblatt. W-Series WDU 2.5 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

SB 50 Connectors - up to 120 amps

SB 50 Connectors - up to 120 amps Connectors - up to 120 amps Based off the design pioneered by Anderson in 1953, APP s two pole SB connectors set the standard for DC power distribution and battery connections. connectors feature a one

More information

TriBand Antenna HPA65R-KE4A DATA SHEET

TriBand Antenna HPA65R-KE4A DATA SHEET DATA SHEET Four foot (1.2 m), TriBand, six port antenna with a 65 azimuth beamwidth covering 694-960 MHz and 1695-2690 MHz frequencies Four wide high band ports covering 1695-2690 MHz and two wide low

More information

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW Product datasheet Characteristics ATS01N206QN soft starter for asynchronous motor - ATS01-6 A - 380..415V - 1.5..3 KW Complementary Assembly style Function available Supply voltage limits Main Range of

More information

The SSR P Series. Phase-Fired SCR Power Controllers. for resistive heating loads. Phase-Fired SCR Power Controllers AMPS VAC

The SSR P Series. Phase-Fired SCR Power Controllers. for resistive heating loads. Phase-Fired SCR Power Controllers AMPS VAC The SSR P Series Phase-Fired SCR Power Controllers 15-70 AMPS 80-600 VAC Phase-Fired SCR Power Controllers for resistive heating loads. ROBICON 1996 Rev. 12/96 Applications The SSR P series models are

More information

DIK 1,5 General data Technical data General

DIK 1,5 General data Technical data General General data Order number 2715966 Type DIK 1,5 Barcode number 4017918061715 Unit pack 50 Pcs. Customs tariff 85369010000 Technical data General Number of levels 3 Number of connections 4 Color gray Insulating

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

T-Line, current transformers

T-Line, current transformers Type HF, primary current up to 5000 amps, accuracy classes from 0.2S to 3, highest system voltage 720 volt T-Line, current transformers Catalogue 208 . Table for contents...2 2. Description Current transformers

More information

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions Main catalogue SNK Series Terminal Blocks Accessories Marking Solutions 10 5.2 mm m 0.205 in spacing 53 2.09" 26.7 1.05" 3 4 5 6 7 8 9 10 Save space by connecting s up to 4 mm2 (CB certified) 12 AWG in

More information

Twelve Port Multi-Band Antenna

Twelve Port Multi-Band Antenna DATA SHEET Four foot (1.2 m) multiband, twelve port antenna with a 65 azimuth beamwidth covering 698-798 MHz, 824-896 MHz and 1695-2360 MHz frequencies Total of Eight high band ports, four high wide band

More information

Controls Contactors and Contactor Assemblies Special Applications

Controls Contactors and Contactor Assemblies Special Applications Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for

More information

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications. LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications. Its compact size, high efficiency, excellent reliability together with easy

More information

2.5. Transformers. Mini Power Centers. Distribution Transformers. Product Description

2.5. Transformers. Mini Power Centers. Distribution Transformers. Product Description Distribution.5 Contents Description Motor Drive Isolation............ Mini Power Centers Standards and Certifications............... Catalog Number Selection................ Product Selection.......................

More information

SIRIUS/SIKOSTART Soft Starters For Standard Applications

SIRIUS/SIKOSTART Soft Starters For Standard Applications Overview SIRIUS RW0/1 Various versions of the RW0/1 SIRUS soft starters are available: Standard version for fixed frequency three-phase motors, sizes S00, S0, S2 and S Version for fixed-speed three-phase

More information

TriBand Twelve-Port Antenna

TriBand Twelve-Port Antenna DATA SHEET Six foot (1.8 m) TriBand, twelve port antenna with a 65 azimuth beamwidth covering 694-960 MHz and 1695-2690 MHz frequencies Eight wide high band ports covering 1695-2690 MHz and four wide low

More information

Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System

Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System Technical Data TD008010EN Supersedes February 2016 Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System The information below is taken directly from the National Electrical CodeT (NEC)

More information

Multi-Band Twelve-Port Antenna

Multi-Band Twelve-Port Antenna DATA SHEET Eight foot (2.4 m) multiband, twelve port antenna with a 65 azimuth beamwidth covering 698-896 MHz and 1695-2400 MHz frequencies Eight high band ports covering 1695-2400 MHz and four low band

More information

OctoPort Multi-Band Antenna

OctoPort Multi-Band Antenna DATA SHEET Four foot (1. m) multiband, eight port antenna with a 65 azimuth beamwidth covering 698-798, 84-896 MHz and 1695-400 MHz frequencies Four wide high band ports covering 1695-400 MHz and four

More information

Item Number No. Poles NO/NC V DC 50/60 Hz. Aux Contactor NO/NC Resistive/ Inductive Amps Price. AF Series

Item Number No. Poles NO/NC V DC 50/60 Hz. Aux Contactor NO/NC Resistive/ Inductive Amps Price. AF Series ABB Contactors Fits 35mm DIN rail Touch Safe Design Compact Design Captive Terminal Screws Built in surge protection (AF series only) Magnetic coil (AE series only) Electronically controlled coil (AE series

More information

Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL77/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the UL489/CSA C22.2 No.5-02,

More information

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60 Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60 Zero switching (RM1A) or instant-on switching (RM1B) AC Solid State Relay Direct copper bonding

More information

2.5. Adjustable Frequency Drives. SVX9000 Drives. Dimensions Approximate Dimensions in Inches (mm)

2.5. Adjustable Frequency Drives. SVX9000 Drives. Dimensions Approximate Dimensions in Inches (mm) Adjustable Frequency Drives.5 Dimensions 9000X Open Drives NEMA Type 1/IP1 and NEMA Type 1/IP54, FR4, FR5 and FR6 H EATON W D Voltage hp (I H ) H D W R1 R Knockouts at Inches (mm) N1 (O.D.) FR4 30V 3/4

More information

Series P. Applications

Series P. Applications Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any

More information

Hybrid Bi-SectorTM Array

Hybrid Bi-SectorTM Array DATA SHEET Eight foot (2.4m), multiband, ten port Hybrid Bi-Sector Antenna. Deploying a high performing 65 azimuth beamwidth covering 698-960 MHz and a pair of CCI s Patented Asymmetrical 33 Shaped Beams

More information

Twelve Port Multi-Band Antenna

Twelve Port Multi-Band Antenna DATA SHEET Twelve Port Multi-Band Antenna Eight foot (2.5 m) multiband, twelve port antenna with a 45 azimuth beamwidth covering 698-960 MHz and 1695-2360 MHz frequencies Eight wide high band ports covering

More information

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60 Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60 Zero switching (RM1A) or instant-on switching (RM1B) AC Solid State Relay Direct copper bonding

More information

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications. LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications. Its compact size, high efficiency, excellent reliability

More information

Review 6. unlike poles cause the magnets to attract. like poles cause the magnets to repel.

Review 6. unlike poles cause the magnets to attract. like poles cause the magnets to repel. Review 6 1. The two characteristics of all magnets are: they attract and hold Iron, and, if free to move, they will assume roughly a south - north position. 2. Lines of flux always leave the north pole

More information

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description General-Purpose Encapsulated.4 Type EP 3 5 Contents Description General-Purpose Encapsulated Catalog Selection................ Product Selection....................... Single-Phase..........................

More information

ACCESSORIES. Type No. of poles Item Part No. Performance. Contact arrangement 1 Form C 2 Form C Max. continuous current (Ambient temperature:

ACCESSORIES. Type No. of poles Item Part No. Performance. Contact arrangement 1 Form C 2 Form C Max. continuous current (Ambient temperature: ACCESSORIES HN RELAYS (Sockets and DIN rail s) TYPES Type No. of poles Item Part No. PC board DIN rail Standard packing: Carton: 0 pcs.; Case: 00 pcs. Note: Certified by UL/C-UL -pole HN PC board AHNA3

More information

Solid State Relay. Zero Switching Types RGC Solid State Contactor 'U' Connection. Product Description RGC 1 A 60 A 40 K G U _.

Solid State Relay. Zero Switching Types RGC Solid State Contactor 'U' Connection. Product Description RGC 1 A 60 A 40 K G U _. Solid State Relays Zero Switching Types RGC Solid State Contactor 'U' Connection Product Width ranging from 17.5mm up to 70mm Rated Operational voltage: Up to 600VAC Rated Operational current: Up to 85AAC

More information

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies. LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies. Its compact size, high efficiency, excellent reliability together with easy installation due to pluggable connectors makes

More information

Solid-State Switching Devices

Solid-State Switching Devices SIRIUS Solid-State Switching Devices Contents Pages Introduction.................................. 8/2 Solid-state switching devices General data.................................. 8/3 Solid-state switching

More information

FM series position switches

FM series position switches FM series position switches Selection diagram 0 08 0 A A 0 A 0 External rubber gasket External rubber gasket External rubber gasket External rubber gasket 0 69 Round rod, stainless steel Square rod Glass

More information

2.1. Product Description

2.1. Product Description .1 NEMA TP-1 Energy-Efficient Type DT-3 Contents Description NEMA TP-1 Energy-Efficient Features, Benefits and Functions........... Standards and Certifications............... Catalog Selection................

More information

Control Relays and Timers

Control Relays and Timers Control Relays and Timers Universal TR Series TR Series.8 Product Selection Guide......................................... 2 Product Overview.............................................. 3 Universal TR

More information

Note: The let-through of the protective device must be equal to or less than the short-circuit current rating of the component being protected.

Note: The let-through of the protective device must be equal to or less than the short-circuit current rating of the component being protected. CONDUCTOR SHORT-CIRCUIT PROTECTION Introduction: This paper analyzes the protection of wire from fault currents. It gives the specifier the necessary information regarding the short-circuit current rating

More information

Ground Clamps Cable Tray

Ground Clamps Cable Tray commercial and industrial fittings: ing Fittings and Solderless Connectors Clamps Cable Tray Terminates ground wire to cable tray. For aluminum or copper conductors. 1 4 hex wrench tightens both tray and

More information

Twelve Port Multi-Band Antenna

Twelve Port Multi-Band Antenna DATA SHEET Eight High Broadband ports covering PCS, AWS / AWS-3 and WCS bands (698-798 MHz, 824-896 MHz. & 1695-2360 MHz.) Four Low Band ports covering 700 MHz and 850 MHz bands Supports 8x8 MIMO in high

More information

08/07/2015

08/07/2015 17.5 mm - 1 Solid State Relay 0.7A MUS2 Part number 88827004 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external

More information