Datasheet. Electronic Circuit Protection ESX10-T

Size: px
Start display at page:

Download "Datasheet. Electronic Circuit Protection ESX10-T"

Transcription

1 Datasheet Electronic Circuit Protection ESX0-T selected in fixed values from 0.5 A...2 A. Failure and status indication are provided by a multicolour LED and an integral short-circuit-proof status output or a relay signal contact. Remote operation is possible by means of a remote reset signal or a remote ON/OFF control signal. The manual ON/OFF button allows separate actuation and reset of individual circuits. Upon detection of over or short circuit in the circuit, the MOSFET of the output will be blocked to interrupt the current flow. The circuit can be re-activated via the remote electronic reset input, control input or manually by means of the ON/OFF button. Electronic circuit protection type ESX0-T is designed to ensure selective disconnection of 24VDC systems. 24VDC power supplies, which are widely used in industry today, will shut down the output in the event of an over with the result that one faulty in the system can lead to complete disconnection of all s. Through selective disconnection the ESX0-T responds much faster to over or short circuit conditions than the switch-mode power supply. This is achieved by active current limitation. The ESX0-T limits the highest possible current to.3 to.8 times the selected rated current of the circuit protector. Thus it is possible to switch on capacitive s of up to 20,000 µf, but they are disconnected only in the event of an over or short circuit. For optimal alignment with the characteristics of the application the current rating of the ESX0-T can be Features Selective protection, electronic trip characteristics Active current limitation for safe connection of capacitive s up to 20,000 µf and on over/short circuit Current ratings 0.5 A...2 A Reliable over disconnection with. x In plus, even with long lines or small cable cross sections (see table 3) Manual ON/OFF button (S) Control input IN+ for remote ON/OFF signal (option) Electronic reset input RE (option) Clear status and failure indication through LED, status output SF or Si contact F Integral fail-safe element adjusted to current rating Width per unit only 2.5 mm Rail mounting Ease of wiring through busbar and 0 V as well as signal bars and bridges Canada Weidmuller, Canada 0 Spy Court Markham, Ontario L3R 5H6 Telephone: (800) Facsimile: (905) info@weidmuller.ca Website: Mexico Weidmuller, Mexico Blvd. Hermanos Serdán 698 Col. San Rafael Oriente Puebla, Puebla, Mexico C.P Telephone: Facsimile: clientes@weidmuller.com.mx Website: United States Weidmuller 82 Southlake Blvd. Richmond, Virginia Telephone: (800) Facsimile: (804) info@weidmuller.com Website:

2 Electronic Circuit Protection Approvals Technical data (Tambient = 40 C, operating voltage Ub = 24VDC) ESX0-T Authority Voltage rating Current ratings UL 2367 (E306740) 24VDC A UL 604 (E322549) (class I, div. 2, group A, B, C, D) 24VDC A UL508 / cul VDC A CSA C22.2 No: 23 (class, division 2) pending CSA C22.2 No: 42 pending Class 2 Meets requirement for Class 2 current limitation (ESX0-T -0.5 A / A / 2 A / 3 A) Technical data Operating data Operating voltage Ub 24VDC ( V) (Tambient = 40 C, operating voltage Ub = 24VDC) Current rating In fixed current ratings: 0.5, A, 2 A, 3 A, 4 A, 6 A, 8 A, 0 A, 2 A Closed current I0 Status indication by means of Load circuit Load output Over disconnection ON condition: typically ma depending on signal output multicolour LED: GREEN: unit is ON, power-mosfet is switched on - status output SF ON, supplies + 24VDC ORANGE: in the event of over or short circuit until electronic disconnection RED: - unit electronically disconnected - circuit/power-mosfet OFF OFF: - manually switched off (S = OFF) or device is dead - undervoltage (U b < 8 V) - after switch-on till the end of the delay period status output SF (option) potential-free signal contact F (option) ON/OFF/ condition of switch S Power-MOSFET switching output (high side switch) typically. x In ( x In) Short-circuit current IK active current limitation (see table ) Trip time for electronic disconnection Temperature disconnection Low voltage monitoring output Starting delay tstart Disconnection of circuit Free-wheeling circuit see time/current characteristics typically 3 s at ILoad >. x In typically 3 s...00 ms at ILoad >.8 x In (or.5 x In/.3 x In) internal temperature monitoring with electronic disconnection with hysteresis, no reset required OFF at Ub < 8 V typically 0.5 sec after every switch-on and after applying Ub electronic disconnection Several outputs must not be connected in parallel external free-wheeling diode recommended with inductive Status output SF Electrical data Status OUT OFF condition Signal output F Electrical data ON condition LED green OFF condition LED off Fault condition LED orange Fault condition LED red ESX0-TB-0 ESX0-TB-02 Fault Reset input RE Electrical data Reset signal RE (terminal 22) Control input IN+ Electrical data Control signal IN+ (terminal 2) Switch S ON/OFF ESX0-TB-4/-24/ plus-switching signal output, connects Ub to terminal 2 of module 7plus nominal data: 24VDC / max. 0.2 A (short circuit proof) status output is internally connected to GND with a 0 kohm resistor ESX0-TB-4/-24 (signal status OUT), at Ub = +24 V +24 V = S is ON, output connected through 0V = S is ON, output blocked and/or switch S is OFF red LED lighted 0 V level at status output when: switch S is in ON position, but device is still in switch-on delay switch S is OFF, or control signal OFF, device is switched off no operating voltage Ub ESX0-TB-0/-02 potential-free signal contact max. 30VDC/0.5 A, min. 0 V/0 ma voltage Ub applied, switch S is in ON position no over, no short circuit device switched off (switch S is in OFF position) no voltage Ub applied over condition >. x In up to electronic disconnection electronic disconnection upon over or short circuit device switched off with control signal (switch S is in ON position) single signal, make contact contact SC/SO-SI open single signal, break contact contact SC/SO-SI closed signal output fault conditions: no operating voltage Ub ON/OFF switch S is in OFF position red LED lighted (electronic disconnection) ESX0-TB-24 voltage: max. +32VDC high > 8VDC 32VDC low 3VDC > 0 V power consumption typically 2.6 ma (+24VDC) min. pulse duration typically 0 ms The electronically blocked ESX0-TB-24 may remotely be reset via an external momentary switch due to the falling edge of a +24 V pulse. A common reset signal can be applied to several devices simultaneously. Switched on devices remain unaffected. ESX0-TB-4 see reset input RE +24V level (HIGH): device will be switched on by a remote ON/OFF signal 0 V level (LOW): device will be switched off by a remote ON/OFF signal unit can only be switched on with S if a HIGH level is applied to IN+ 2

3 ESX0-T Electronic Circuit Protection Technical data (Tambient = 40 C, operating voltage Ub = 24VDC) Table : voltage drop, current limitation, max. current General data Fail-safe element: backup fuse for ESX0-T not required because of the integral redundant fail-safe element Terminals / LOAD+ / 0V screw terminals M4 max. cable cross section flexible with wire end ferrule w/wo plastic sleeve mm 2 multi-lead connection (2 identical cables) rigid/flexible mm 2 flexible with wire end ferrule without plastic sleeve mm 2 flexible with TWIN wire end ferrule with plastic sleeve mm 2 wire stripping length 0 mm tightening torque (EN 60934).2 Nm Terminals aux. contacts screw terminals M3 max. cable cross section flexible with wire end ferrule w/wo plastic sleeve mm 2 wire stripping length 8 mm tightening torque (EN 60934) 0.5 Nm Housing material moulded Mounting symmetrical rail to EN x7.5 Ambient temperature C (without condensation, see EN ) Storage temperature C Humidity 96 hrs/95 % RH/40 C to IEC Cab climate class 3K3 to EN 6072 Vibration 3 g, test to IEC test Fc Degree of protection housing: IP20 DIN terminals: IP20 DIN EMC emission: EN (EMC directive, CE logo) susceptibility: EN Insulation co-ordination 0.5 kv/2 pollution degree 2 (IEC 60934) re-inforced insulation in operating area dielectric strength max. 32VDC ( circuit) Insulation resistance (OFF condition) n/a, only electronic disconnection Approvals UL 2367, File E306740, Solid State Overcurrent Protectors UL 604 (class I, div. 2, zone 2), UL508 pending, CE logo Dimensions (W x H x D) 2.5 x 80 x 83 mm Mass approx. 65 g current rating typically voltage drop active current max. current at 00% ON duty In Uon at In limitation (typically) Tu = 40 C Tu = 50 C 0.5 A 70 mv.8 x In 0.5 A 0.5 A A 80 mv.8 x In A A 2 A 30 mv.8 x In 2 A 2 A 3 A 80 mv.8 x In 3 A 3 A 4 A 00 mv.8 x In 4 A 4 A 6 A 30 mv.8 x In 6 A 5 A 8 A 20 mv.5 x In 8 A 7 A 0 A 50 mv.5 x In 0 A 9 A 2 A 80 mv.3 x In 2 A 0.8 A Attention: when mounted side-by-side without convection the ESX0-T should not carry more than 80% of its rated with 00% ON duty due to thermal effects. Please note: The user should ensure that the cable cross sections of the relevant circuit are suitable for the current rating of the ESX0-T used. Automatic start-up of machinery after shut down must be prevented (Machinery Directive 98/37/EG and EN ). In the event of a short circuit or over the circuit will be disconnected electronically by the ESX0-T. Table 2: ESX0-T - product version Version Signal input Signal output Signal contact Status output without Control input Remote without single signal single signal without Status Signal ON/OFF Reset Reset Signal N/O N/C Signal output Input Output (normally open NO) (normally closed NC) Output = OK ESX0-TA-00 x x x ESX0-TB-0 x x x ESX0-TB-02 x x x ESX0-TB-4 x x ESX0-TB-24 x x x ESX0-TA-00 Current Rating Circuit Protection ESX0-TB-0 Current Rating N/C Contact ESX0-TB-02 Current Rating N/C Contact ESX0-TB-4 Current Rating Control Input ESX0-TB-24 Current Rating Reset Input

4 Electronic Circuit Protection ESX0-T ESX0-T Signal inputs / outputs (wiring diagram) ESX0-TA-00 without signal input/output ESX0-TB-0 without signal input with signal output F (single signal, N/O) ESX0-TB-02 without signal input with signal output F (single signal, N/C) LOAD+ operating condition: 3-4 closed fault condition: 3-4 open operating condition: -2 open fault condition: -2 closed ESX0-TB-4 with control input IN+ (+24VDC) with status output SF (+24 V = output ON) ESX0-TB-24 with reset input RE (+24VDC ) with status output SF (+24 V = output ON) Dimensions SF 23 SF 23 IN 2 RE label snap-on socket for symmetrical rail EN x7.5 operating condition: SF +24 V = OK fault condition: SF 0 V operating condition: SF +24 V = OK fault condition: SF 0 V This is a metric design and millimeter dimensions take precedence ( mm ) inch 4

5 ESX0-T Electronic Circuit Protection Time/Current characteristic curve (Tambient = 40 C) trip time in seconds disconnection typically. x I n.8 x I n *) current limitation *) typically.8 x I n The trip time is typically 3 s in the range between. and.8 x In *). Electronic current limitation occurs at typically.8 x In *) which means that under all over conditions (independent of the power supply and the resistance of the circuit) the max. over before disconnection will not exceed.8 x In *) times the current rating. Trip time is between 00 ms and 3 sec (depending on over or at short circuit) IK...times rated current *) current limitation typically.8 x In times rated current at In = 0.5 A...6 A current limitation typically.5 x In times rated current at In = 8 A or 0 A current limitation typically.3 x In times rated current at In = 2 A Without this current limitation a considerably higher over current would flow in the event of an over or short circuit. Table 3: Reliable trip of ESX0-T Reliable trip of ESX0-T with different cable lengths and cross sections Resistivity of copper ρ 0 = (Ohm x mm 2 ) / m Ub = DC 9.2 V (= 80 % of 24 V) voltage drop of ESX0-T and tolerance of trip point (typically. x In = x In) have been taken into account. ESX0-T-selected rating In (in A) 3 6 e. g. trip current Iab =.25 x In (in A) ESX0-T trips after 3 s Rmax in Ohm = (Ub / Iab) The ESX0-T reliably trips from 0 Ohm to max. circuitry resistance Rmax Cable cross section A in mm cable length L in meter cable resistance in Ohm = (R0 x 2 x L) / A (= single length) Example : max. length at.5 mm 2 and 3 A 24 m Example 2: max. length at.5 mm 2 and 6 A 06 m Example 3: mixed wiring: R = 40 m in.5 mm 2 and R2 = 5 m in 0.25 mm 2 : (Control cabinet sensor/actuator level) R = 0.95 Ohm, R2 = 0.7 Ohm Total (R + R2) =.66 Ohm 5

6 Electronic Circuit Protection ESX0-T Mounting examples for ESX0-T The ESX0-T features an integral power distribution system. busbar continuous busbar 500 mm length, cut (2.5 x n)-3 = length of busbars ± 0.5 e. g. (2.5 x 5)-3 = 59.5 ± 0.5 signal bar or jumper remove protection against brush contact from bottom side 0V busbar insert protection against brush contact insert busbars and protection slides to be flush with housing sides 2.5 x n = width of protector block e. g. 2.5 x 5 = 62.5 insert signal bars to be flush with housing and place them centrally over the contacts 5 ESX0-TB with busbars and jumpers 5 ESX0-TA with busbars Mounting procedure: Before wiring insert busbars into protection block. 6

7 ESX0-T Electronic Circuit Protection Connection diagrams and application examples ESX0-T Signal contacts are shown in OFF or fault concition. ESX0-TA-00 ESX0-TB-0 group signaling (series connection) terminals for busbars screw terminals for the SI busbar LINE + busbar +24V +24V group signalling by means of an LED power supply DC 24 V ESX0-TA-00 ESX0-TA-00 ESX0-TA-00 power supply DC 24 V ESX0-TB-0 ESX0-TB-0 ESX0-TB-0 jumpers are staggered 0V 0V 0 V busbar 0 V busbar - line entry - line entry ESX0-TB-02 ESX0-TB-24 Single signaling with common line entry Single signaling with common reset for the SI single signalling per way by means of an LED reset button single signalling per way by means of an LED busbar busbar +24V +24V RE SF RE SF RE SF 23 power supply DC 24 V ESX0-TB-02 ESX0-TB-02 ESX0-TB-02 signal busbar for common line entry power supply DC 24 V ESX0-TB-24 ESX0-TB-24 ESX0-TB-24 signal busbar for common reset 0 V 0V 0 V busbar 0 V busbar - line entry - line entry 7

8 Electronic Circuit Protection ESX0-T Accessories for ESX0-T Description The ESX0-T features an integral power distribution system. The following wiring modes are possible with various pluggable current and signal busbars: LINE +(24VDC) 0 V Caution: The electronic devices ESX0-T require a 0 V connection signal contacts reset inputs Description Part No. Busbars for and 0 V max. with one line entry Imax 50 A (recommended: centre line entry) max. with two line entries Imax 63 A length: 500 mm Signal busbars for signal contacts and reset inputs max. with one line entry Imax A with one series connection of signal contacts Imax 0.5 A length: 500 mm Jumpers for signal contacts length: packing unit: 2 mm 0 pcs All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 8 07/09 2.5M LIT0806

Electronic Circuit Protector ESX10-T

Electronic Circuit Protector ESX10-T Electronic Circuit Protector ESX0-T Description Electronic circuit protector type ESX0-T is designed to ensure selective disconnection of systems. power supplies, which are widely used in industry today,

More information

Electronic Circuit Protector ESX10

Electronic Circuit Protector ESX10 Electronic Circuit Protector ESX0 Description Electronic circuit protector type ESX0 is designed to ensure selective disconnection of DC 24 V load systems. DC 24 V power supplies, which are widely used

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,

More information

Electronic circuit breaker ESS30-Sxxx-DC24V

Electronic circuit breaker ESS30-Sxxx-DC24V Electronic circuit breaker ESS30-Sxxx-DC2V Description The electronic circuit protector ESS30-S with physical isolation is the globally unique electronic over protection for DC 2 V applications as a low

More information

PHOENIX CONTACT - 09/2009

PHOENIX CONTACT - 09/2009 Electronic miniature circuit-breaker CLIPLINE Data sheet 03906_en_0 PHOENIX CONTACT - 09/2009 Description The EC-E... electronic miniature circuit-breaker selectively protects all 24 V DC load circuits

More information

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1 Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch

More information

PHOENIX CONTACT

PHOENIX CONTACT Electronic circuit breaker CLIPLINE Data sheet 102898_en_03 PHOENIX CONTACT 2010-12-17 1 Description The electronic circuit breaker can be used in applications that cover all aspects of the switched-mode

More information

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1 Electronic Circuit Breaker ESS for System SVS Description The electronic circuit breaker ESS is designed to ensure selective disconnection of individual loads in industrial systems which are powered by

More information

Electronic circuit protector REX12

Electronic circuit protector REX12 Description The new electronic overcurrent protection REX12 consists of the supply module EM12-T and the single or double channel electronic circuit protector REX12-T which allows modular side-by-side

More information

Datasheet. PRO-M Series Power Supplies

Datasheet. PRO-M Series Power Supplies Datasheet PRO-M Series Power Supplies N E W These compact and efficient power supplies are optimized for machinery, with features that include overload resistance and high performance reserves. They also

More information

REX12 Electronic Circuit Protector

REX12 Electronic Circuit Protector Description The compact and flexible all-in-one solution REX consists of several perfectly matched components. It comprises the EM12-T supply module for the plus and minus potential via a single or double

More information

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1 Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch

More information

REX12 Electronic Circuit Protector

REX12 Electronic Circuit Protector Description The compact and flexible all-in-one solution REX consists of several perfectly matched components. It comprises the EM12-T supply module for the plus and minus potential via a single or double

More information

PHOENIX CONTACT

PHOENIX CONTACT Selective circuit breaker CLIPLINE Data sheet 100464_en_05 PHOENIX CONTACT 2009-11-17 1 Description The electronic circuit breaker, which has a design width of just 12.5 mm, selectively protects all 24

More information

Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL77/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the UL489/CSA C22.2 No.5-02,

More information

NEW. Datasheet. ACT20M Signal Isolation and Conversion

NEW. Datasheet. ACT20M Signal Isolation and Conversion Datasheet ACT0M Signal Isolation and Conversion NEW High quality signal isolation and conversion in a slim wide housing format is now available with Weidmuller s ACT0M range. Featuring worldwide approvals

More information

Datasheet WPDB Power Distribution Blocks

Datasheet WPDB Power Distribution Blocks Datasheet WPDB Power Distribution Blocks Now you can manage multiple load connections and a wide range of wire sizes with Weidmuller s Power Distribution blocks. By using the best materials and the best

More information

Datasheet WPDB Power Distribution Blocks

Datasheet WPDB Power Distribution Blocks Datasheet WPDB Power Distribution Blocks Now you can manage multiple load connections and a wide range of wire sizes with Weidmuller s Power Distribution blocks. By using the best materials and the best

More information

Smart Power Relay E I...

Smart Power Relay E I... Smart Power Relay E-48-8I... Description The Smart Power Relay E-48-8I.- is a remotely controllable electronic load disconnecting relay with three functions in a single unit: l electronic relay l electronic

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A Switched mode power supply for DIN rail mounting type SMP DC4V/40A Description Switched mode power supply (SMP) for rail mounting, three-phase supply voltage, high efficiency, integral input filter and

More information

Control module CP-A CM

Control module CP-A CM 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,

More information

PowerPlex Compact Module PP-C-COM24

PowerPlex Compact Module PP-C-COM24 Description The PowerPlex Compact Module has been designed for the 12 V or 24 V DC-System of special vehicles, buses or boats. It provides inputs for switches and sensors as well as power outputs with

More information

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A Switched mode power supply for DIN rail mounting type SMP2 DC24V/0A Description Switched mode power supply for rail mounting, with independent change-over of input voltages (AC 5/20 V), integral passive

More information

Datasheet ACT20M Signal Isolation and Conversion NEW

Datasheet ACT20M Signal Isolation and Conversion NEW Datasheet ACT0M Signal solation and Conversion NEW High quality signal isolation and conversion in a slim wide housing format is now available with Weidmuller s ACT0M range. Features include worldwide

More information

CP-T range Product group picture

CP-T range Product group picture Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details

More information

QUINT-PS/ 3AC/24DC/10

QUINT-PS/ 3AC/24DC/10 Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 Description PHOENIX CONTACT - 09/2009 Features QUINT POWER power supply units Maximum system

More information

CP-T range Benefits and advantages

CP-T range Benefits and advantages Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers

More information

Power Distribution System SVS18

Power Distribution System SVS18 Power Distribution System SVS8 Description The power distribution system SVS8 optimises the DC V distribution in automation and process control, in the production area of the chemical industry and in power

More information

CP-E range Benefits and advantages

CP-E range Benefits and advantages Benefits and advantages Characteristics Output voltages 5 V, 12 V, 2 V, 8 V DC Adjustable output voltages Benefits Signalling output/contact Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / A / 5 A

More information

Power distribution system SVS25

Power distribution system SVS25 Power distribution system SVS Description The new power distribution system type SVS meets all requirements of the automation technology with regard to reliably overcurrent protection and optimised current

More information

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage

More information

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24... P AC/DC current monitoring Multifunction Supply voltage 24-240V DC or 110-240V AC 1 change-over contact Width 22,5 mm Control element Tripping delay Maximum threshold Minimum threshold Function selector

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

QUINT-PS/ 3AC/24DC/40

QUINT-PS/ 3AC/24DC/40 Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum

More information

QUINT-PS AC/24DC/40

QUINT-PS AC/24DC/40 Power supply unit INTERFACE Data sheet 102315_en_02 1 Description PHOENIX CONTACT 2010-04-23 Features QUINT POWER power supply units for plant and special engineering reliably start heavy loads with high

More information

Solid State Remote Power Controller E

Solid State Remote Power Controller E Solid State Remote Power Controller E-048-60. Description The E-T-A Solid State Remote Power Controller (SSRPC) E-048-60. is an opto decoupled transistorised switching device providing both protection

More information

Primary switch mode power supplies Product group picture

Primary switch mode power supplies Product group picture Primary switch mode power supplies Product group picture /1 ABB Catalog Electronic Products and Relays 2015 2CDC 110 004 C0210 Primary switch mode power supplies Table of contents Primary switch mode power

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C),

More information

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA P Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Contact expander module for increasing the number of available contacts Approvals Unit features Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous

More information

Electronic circuit protector ESX10-Sxxx-DC24V-1A-10A

Electronic circuit protector ESX10-Sxxx-DC24V-1A-10A Eectronic circuit protector ESX10-Sxxx-DC2V-1A-10A Description The mode ESX10-Sxxx extends our product group of eectronic overcurrent protection devices for DC 2 V appications. At a width of ony 12.5mm

More information

QUINT-PS/ 1AC/24DC/20

QUINT-PS/ 1AC/24DC/20 Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data sheet 103129_en_04 1 Description PHOENIX CONTACT - 02/2010 Features QUINT POWER power supply units Maximum system

More information

Power supply CP-E 24/0.75

Power supply CP-E 24/0.75 2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output

More information

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply Data sheet Power supply CP-T 24/10.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

MINI-PS AC/2X15DC/1

MINI-PS AC/2X15DC/1 MII-PS-100-240AC/2X15DC/1 Power supply unit ITERFACE Data sheet 100299_en_04 1 Description PHOEIX COTACT - 2010-10-20 Features MII POWER is the extremely slim power supply unit with constructional widths

More information

27/04/2015

27/04/2015 Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement

More information

Switching power supplies CP range, Linear power supplies CP-L range. Content

Switching power supplies CP range, Linear power supplies CP-L range. Content CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional

More information

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Control module CP-A CM

Control module CP-A CM Control module 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP-A RU Adjustable threshold values (14-28 V) and relay outputs per input / channel Approvals Marks g 6 7 1 3 4 2 8 5 Order data

More information

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance

More information

Phase control Single function phase control relay - 7.5 mm Control of -phase networks: phase sequence, total phase failure Multi-voltage from x 08 to x 480 V Controls its own supply voltage True RMS measurement

More information

EPSITRON Electronic Circuit Breakers For Secondary Side DC Protection

EPSITRON Electronic Circuit Breakers For Secondary Side DC Protection EPSITRON Electronic Circuit Breakers For Secondary Side DC Protection WHY SECONDARY-SIDE PROTECTION? Switched-mode power supplies provide secondary side DC voltage to control circuits and loads such as

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

Power supply CP-E 24/20.0

Power supply CP-E 24/20.0 2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output

More information

ISOMETER IRDH575. Approvals

ISOMETER IRDH575. Approvals Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Electronic timer CT-TGD.22

Electronic timer CT-TGD.22 2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300 Monitoring Technique VARIMETER IMD Insulation monitor RN 5897/300 0274214 Your Advantages For mobile generator sets according to DIN VDE 0100-551 Preventive fire and system protection Detection of symmetric

More information

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103129_en_01 PHOENIX CONTACT - 05/2008 1 Description QUINT POWER power supply units highest system availability

More information

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103383_en_00 1 Description PHOENIX CONTACT - 06/2008 Features QUINT POWER power supply units highest system

More information

Type Nominal voltage (V) Code HSV V

Type Nominal voltage (V) Code HSV V Speed control Speed control relay - mm Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - -wire PNP or NPN, Namur, voltage 0-0V or volt-free contact type Works

More information

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC Features DIN-Rail 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection Parallel

More information

Power Distribution System SVS02

Power Distribution System SVS02 Power Distribution System SV2 Description The ETA power distribution system SV2 is designed to accommodate the electronic circuit breaker series ESS20003 or electronic circuit protector ESX0. It distributes

More information

QUINT-PS-24DC/24DC/10

QUINT-PS-24DC/24DC/10 QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage

More information

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power Distribution System SVS20

Power Distribution System SVS20 Power Distribution System SV Description The power distribution system SV for rail mounting distributes the current supplied by a DC V switchmode power supply to channels and selectively protects the connected

More information

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC 2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from

More information

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

DSA150 Series. xxx Series. 150 Watts.   AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125. 15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

Power Supplies 3. SDN-C Compact DIN Rail Series

Power Supplies 3. SDN-C Compact DIN Rail Series SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks. 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Up to Category 2, EN 954-1 Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button LED indicator for: Switch status channel

More information

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC Features DIN-Rail Description 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection

More information

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks. 2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6

More information

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power Distribution System SVS02

Power Distribution System SVS02 Power Distribution System SV Description The ETA power distribution system SV is designed to accommodate the electronic circuit breaker series ESS0003 or electronic circuit protector ESX0. It distributes

More information

Power supply CP-D 24/1.3

Power supply CP-D 24/1.3 2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power

More information

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz HPL11002EN DILETTiming relays Rated operational current AC-11 230 V 400 V I th I e I e A A A A A Conventional thermal current Time Range Voltage Article No. See price list Std. pack On-delayed Timing functions

More information

Energy Management Energy Meter Type EM110

Energy Management Energy Meter Type EM110 Energy Management Energy Meter Type EM110 Single phase energy meter Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Electro-mechanical display Energy readout on display: 6+1 digit

More information

Solid-state Twin Timer

Solid-state Twin Timer Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time

More information

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description Primary-switched power supply unit Data sheet 106261_en_02 PHOEIX COTACT 2015-05-13 1 Description The power supply makes a worldwide impression thanks to maximum energy efficiency. ow idling losses (o

More information

Three-phase monitoring relays

Three-phase monitoring relays 2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted

More information

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet 2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer

More information

Multifunctional counter tico 772/773/774

Multifunctional counter tico 772/773/774 Universally applicable as a tachometer, timer, shift counter, batch counter Easy to operate Four different backlight colours Intensity of backlighting can now be adjusted Large, clearly readable 48 x 48

More information

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description. Electronic monitoring relay for voltage monitoring in three-phase networks INTERFACE Data sheet 102110_en_03 1 Description PHOENIX CONTACT - 09/2009 Features Increasingly higher demands are being placed

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable

More information

05/09/2012

05/09/2012 17.5 mm EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer ON LED) Option

More information

Zelio Control Measurement Relays

Zelio Control Measurement Relays Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and

More information

Solid-State Digital Counter H7AN

Solid-State Digital Counter H7AN Solid-State Digital Counter Preset and Totalizing Counters with Up to 8-Digit LED Displays Draw-out construction allows setting, servicing without disconnecting wiring Choose from selectable UP/DOWN or

More information

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and

More information

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004 Current Monitoring Relay Data Sheet 08/2004 Functions Structure Current monitoring of direct and alternating current in 1-phase networks with settable threshold values, starting override and response delay

More information

Subject to changes 11/2003 Page 1/7

Subject to changes 11/2003 Page 1/7 Main Characteristics: Zero switching. LED display. Various connection systems. Plug-in control terminal. Degree of protection IP 2. Double-insulated design. General Data: Standards / Approvals DIN EN 697--3

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information